You are on page 1of 1

BUTTERFLY VALVE FLANGE BOLTING GUIDE

Wafer Valve & Cap Screws Wafer Valve & Stud Bolts

Size D TPI L Qty. Size D TPI L Qty.


2 5/8” 11 4-1/4” 4 2 5/8” 11 5-1/8” 4
2-1/2 5/8” 11 4-3/4” 4 2-1/2 5/8” 11 5-1/8” 4
3 5/8” 11 5” 4 3 5/8” 11 5-1/2” 4
4 5/8” 11 5” 8 4 5/8” 11 5-1/2” 8
5 3/4" 10 5-1/4” 8 5 3/4" 10 6-3/8” 8
6 3/4" 10 5-1/2” 8 6 3/4" 10 6-3/8” 8
8 3/4" 10 6” 8 8 3/4" 10 6-1/4” 8
10 7/8” 9 6-1/2” 12 10 7/8” 9 7-1/2” 12
12 7/8” 9 7” 12 12 7/8” 9 8-3/8” 12
14 1” 8 8” 12 14 1” 8 8-3/4” 12
16 1” 8 8-3/4” 16 16 1” 8 10” 16
18 1-1/8” 7 9-1/2” 16 18 1-1/8” 7 11-1/8” 16
20 1-1/8” 7 10-1/2” 20 20 1-1/8” 7 12” 20
24 1-1/4” 7 12” 20 24 1-1/4” 7 13-13/16” 20

Size D TPI L Qty.


2 5/8” 11 1-1/2” 8
Lug Valve & Cap Screws 2-1/2 5/8” 11 1-3/4” 8
3 5/8” 11 1-3/4” 8
4 5/8” 11 1-3/4” 16
5 3/4" 10 2” 16
6 3/4" 10 2” 16
8 3/4" 10 2-1/4” 16
10 7/8” 9 2-1/2” 24
12 7/8” 9 2-3/4” 24
14 1” 8 2-3/4” 24
16 1” 8 3-1/4” 32
18 1-1/8” 7 3-1/2 32
20 1-1/8” 7 4” 40
24 1-1/4” 7 4-3/4” 40

WARNING: Improper bolt and stud lengths could result in leakage at the flange resulting in damage, serious injury, or death.

CAUTION: Dimensions provided for flange bolting are intended only as a guide. Bolt lengths may vary due to manufacturing
tolerances in valves, gaskets, flange bolts, and flanges. ZSPEC resilient seated butterfly valves are designed to fit between
ANSI B16.5 class 150 flanges without flange gaskets. Since inside flange diameters vary depending on the type of flange,
always verify that the connecting pipe flange face fully engages the valve seat face before installation.