You are on page 1of 2

L-VIS LVIS-3ME7 Touch Panel 7"

LVIS-3ME12 Touch Panel 12.1"


LVIS-3ME15 Touch Panel 15"
RS-485 FT ETH2 RESET
STATUS LED Installation instructions
ETH1 PC USB STATUS

Instructions de montage Instruzioni di montaggio


Montageanweisung Instrucciones de montaje
Status LEDs Montagevoorschrift Monteringsanvisning
RS-485 BACnet MS/TP enabled:
MS/TP GREEN flashing Traffic on BACnet MS/TP (multi master)
ORGANE flashing Traffic on BACnet MS/TP (single master)
RED permantent with 25
GREEN flashing Token lost, cable might be broken Dimensions in mm
max 40º C
RED flashing fast Transceive Errors, bad cabling DIM 7” 12.1” 15”
RS-485 Modbus RTU enabled: min 10º C A 223.5 329 394
B 162 268.3 318 kg
Modbus GREEN flashing Traffic on Modbus RTU port C 3 4 4
RED flashing Device not responding or network error D 61 61 61 7” 1.200 kg
RH E 142 249 293.7 12.1” 2.500 kg
FT GREEN flashing fast Traffic on CEA-709 port F 194 299 353 15” 3.500 kg
GREEN flashing at 1 Hz CEA-709 port not commissioned 10 - 90 % G 153.5 246 304.4 F
H 92 185.3 228.25
RED permanent CEA-709 port is damaged
C D
RED flashing fast Traffic overload on CEA-709 port
ETH 1, GREEN Ethernet link
ETH 2 GREEN flashing Ethernet traffic
STATUS GREEN Power on, Normal operation
OFF Power off
ORANGE flashing Fall-Back Mode
Buttons
RESET Reset
STATUS CEA-709: Send service pin message / BACnet: Send I-Am message

≈ 1600

H
E

B
Node ID of CEA-709 Port

Virtual (Node) ID of CEA-852 port (Ethernet)


LOYTEC electronics GmbH
NID1
8000000350EF LVIS-3ME12 Date Code
VID1
MAC address of CEA-852 Ethernet port MAC1
8000000350F0

000AB0011D87 MADE IN
AUSTRIA G
W51/2014
A
Serial number of the device
SER#
007902-8000000350EF

Document 88083301
2014-11
Printed in Austria
Data is subject to change http://www.loytec.com
support@loytec.com User: admin
Caution: Only use countersunk screws or blind rivets to secure frame
LVIS-MNTKIT-U Mounting Kit Universal is available separately

Dimensions in mm
DEPTH = 61 DIM 7” 12.1” 15”
Ø 4.5 mm
J 195 300 355
K 143 250 295
L 206 310 365 GND
M 21 25 47.5

K
S
TEMP
+3 V
N 62 105 132.5

P
DIGIN1
GND
CABLE ENTRIES P 30 50 46.7

R
DIGIN0
N Q Q 70 90 90
DC only! AUDIO OUT
R 50 100 100 POWER1 POWER2 USB1 Ethernet1 FT/LPT RS-485 Extension
Ø 25 mm M S 60 100 100 1 2 4 5 USB2 Ethernet2 6 7 8 9 10 11

only
J LVIS-3ME12
LVIS-3ME15
L Extension
cable
85 - 264 VAC 61006001

GND
-+ 2 x USB Stereo Plug BA + -
Theft Protection EARTH
24 VDC 2 x 10/100Base-T
CEA-709
(RJ45)
RS-485

PE
Use L-TERM termination for the bus lines:
FT/LPT (CEA-709): LT-03, LT-13, or LT-33
RS-485: LT-04, or LT-B4

12“ / 15“: PROTECTIVE EARTH MUST BE CONNECTED!


4x M3x50 Connectors
(optional) to TRS connector Extension cable
attach display POWER1 only LVIS-3ME12, LVIS-3ME15
Stereo 3.5 mm Nr. 61006001
to frame 85-264 VAC 1 Power supply AC input
2 Power supply AC input Modular
POWER2 4 Power supply DC input MINUS connector
24 VDC 5 Power supply DC input PLUS 6p6c (RJ12)
do not connect PLUS to GND
CEA-709 6 Input earth ground
TP/FT-10 7 Input B
black GND
TP/LPT 8 Input A
green TEMP
RS-485 9 RS-485 GND
red +3 V
10 RS-485 PLUS
white DIGIN1
11 RS-485 MINUS
blue GND
Weidmüller BLZP 5.08/03/180 (3 pin) yellow DIGIN0
BLZP 5.08/02/180 (2 pin)
All connected together

0,2 - 2,5 mm 2

Order Number: - GND


7”: LVIS-FRAME7
12.1”: LVIS-FRAME12
4.5 lb-in/0.5 Nm 7
15”: LVIS-FRAME15

License Notice: This product contains components covered by the GPL and LGPL.
Details on device Web UI or http://loytec.com/os/

You might also like