You are on page 1of 60

MXM DICTIONARY

not permitted without written authorization from Alcatel.


All rights reserved. Passing on and copying of this
document, use and communication of its contents

TABLE OF CONTENTS

HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Utilization of dictionary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2 ALPHABETIC LIST OF MNEMONICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

02 020827 MPDL/DTNE P.Mouzer

01 011022 MPDL/DTNE P.Mouzer

ED DATE CHANGE NOTE APPRAISAL AUTHORITY ORIGINATOR


1AA 00014 0004 (9007) A4 – ALICE 04.10

DICTIONARY OF MNEMONICS
MXM Dictionary
RCP R7.2 – MNERCP

ED 02

3BL 33096 CCAA ADAHA 1 / 60

60
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization from Alcatel.
1AA 00014 0004 (9007) A4 – ALICE 04.10
ED

Update document 3BL33096CCAAADAHA Ed.01.


02 on 02–08–27

Creation for RCP R7.2 from 3BL33096CBAAADAHA Ed.02 (R7.1).


01 on 01–10–22

HISTORY
02
3BL 33096 CCAA ADAHA
60

2 / 60
1 INTRODUCTION

The present document provides the list of mnemonics used in operator commands for the operation and
maintenance of RCP.
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents

1.1 Utilization of dictionary

The mnemonics are classified by alphabetic order.

A same parameter can be used :


– In input.
– In output.
– In input and output.

When a symbol defines a parameter used in input, ”Symbolic input parameter name” is specified.

When a symbol defines a parameter used in output, ”Symbolic output parameter name” is specified.

When a symbol defines a parameter used in both input and output ”Symbolic input and output parameter
name” is specified

When a symbol defines a parameter value, ”parameter value ” is specified.

When a symbol is used several times and each time with the same meaning, it is only defined once.

When a symbol is used several times and each time with a different meaning, specific mention is made
each time the meaning differs.
1AA 00014 0004 (9007) A4 – ALICE 04.10

ED 02

3BL 33096 CCAA ADAHA 3 / 60

60
2 ALPHABETIC LIST OF MNEMONICS

ACCESS Result determined by type of access ( type of result )


• TYPE input and output parameter value
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents

ADD Digits to be added


• Symbolic input and output parameter name
• Parameter value: from 1 to 20 digits (0 to 9, A and B)
– value A to code *
– value B to code #
NU value: Deletion of the parameter value (in input)

ADDSCCP Rank and Digits to be inserted in the SCCP Called Party Address
• Symbolic input and output parameter name
• Parameter value: rk–digits
– rk : from 0 to 16, 0 indicates no addition of any digits. If rk is greater than the number length,
then the digits are to be inserted at the end of the number.
– digits : 1 to 8 digits ( not significant if rk = 0 )

ADDNAT ISDN address type


• Symbolic input and output parameter name
• Parameter value: NATIO, INTE, UKN

ADDNUM Additional number analysis


• ANA input and output parameter value

AIS Reception of continuous ”1” on the PCM link


• TYPFAU output parameter value

ALL Same MSRN pool for all mobiles (INTER and INTRA)
• ROAMTYP input and output parameter value

ALL All the basic services applicable in VLR


• BS input parameter value

ALL Originating call and forwarded call (CAMEL)


• CTCRI output parameter value

ALLOWLAC Authorized LACs value (regional subscription)


• Symbolic input parameter name
• Parameter value: from 1 to 65533 or 0 ”zero” (all the existing local LACs are authorized)

AMRHO AMR Handover


• Symbolic input and output parameter name
• Parameter value:
Y : if AMR handover is allowed when both rates are used (default value)
N : if AMR handover is not allowed when both r ates are used

AMRPRATE AMR preferred Rate


• Symbolic input and output parameter name
• Parameter value:
FR : when both rates are used, Full Rate is preferred (default value)
HR : when both rates are used, Half Rate is preferred
1AA 00014 0004 (9007) A4 – ALICE 04.10

MS : when both rates are used, the MS choice for rate and speech versions is kept unchanged

AMRRATE AMR channel Rate

ED 02

3BL 33096 CCAA ADAHA 4 / 60

60
• Symbolic input and output parameter name
• Parameter value:
NONE : the BSC does not support AMR (default value)
FR : if supported by the MS, the AMR codecs are only used in Full Rate mode
not permitted without written authorization from Alcatel.

HR : if supported by the MS, the AMR codecs are only used in Half Rate mode
All rights reserved. Passing on and copying of this
document, use and communication of its contents

BOTH : the AMR codecs are used in both Full and Half Rate modes

ANA Analysis type in the target translator


• Symbolic input and output parameter name
• Parameter value:
NUM : numbering analysis itself (default value)
LEN : numbering length analysis
ADDNUM : Additional number analysis
IMSI : International Mobile Subscriber Identity analysis

ANALOG Analog type SMIM test


• TYPTST output parameter value

AOCC Advice of Charge, charging


• ASUPS and SSUPS input and output parameters value

AOCI Advice of Charge, information


• ASUPS and SSUPS input and output parameters value

APCTX Outgoing application context


• Symbolic input and output parameter name
• Parameter value:
Application contexts supported by the system:
INFRET = information retrieval
LOCUPD = location updating
HANDOV = handover control
MSPURG = mobile station purging
NWFSSH = network functional supplementary services handling
NWUSSH = network unstructured supplementary services handling
SMGWAY = short message gateway
SMMORL = mobile originating short message relay
SMTCRL = mobile terminating short message relay
SMWDTM = short message waiting data management
VLRRET = inter VLR information retrieval
LOCRET = location information retrieval
CCOTRA = call control transfer
REPORT = reporting
CCOMP = call completion
SSNOTI = supplementary services notification requested
AUFAIL = authentication failure report
Minimal and maximal version values supported by the system for each application context:
INFRET = V1 and V2
LOCUPD = V1, V2 and V3
HANDOV = V1, V2 and V3
MSPURG = V2 and V3
NWFSSH = V1 and V2
1AA 00014 0004 (9007) A4 – ALICE 04.10

NWUSSH = V2
SMGWAY = V1, V2 and V3
SMMORL = V1, V2 and V3
SMTCRL = V2 and V3

ED 02

3BL 33096 CCAA ADAHA 5 / 60

60
SMWDTM = V1 and V2
VLRRET = V2
LOCRET =V3 (on option)
CCOTRA = V3
not permitted without written authorization from Alcatel.

REPORT = V3
All rights reserved. Passing on and copying of this
document, use and communication of its contents

CCOMP = V3
SSNOTI = V3
AUFAIL = V3

ASUPS Activated supplementary service


• Symbolic input and output parameter name
• Parameter value:
CBOC = Call Barring of all outgoing calls
CBOI = Call Barring of all international outgoing calls
CBOIEXHC = Call Barring of all outgoing international calls except those directed to the home
PLMN country
CFBUSY = Call forwarding on MS busy
CFNREPLY = Call forwarding on no reply
CFNREACH = Call forwarding on MS not reachable
AOCC = Advice of charge charging
AOCI = Advice of charge information
CH = Call hold
CCBSA = Call Completion on Busy Subscriber, A side (on option)
CCBSB = Call Completion on Busy Subscriber, B side (on option)
CW = Call waiting
CLIP= Calling Line Identification Presentation
CLIR = Calling Line Identification Restriction
COLP = Connected Line Identification Presentation
COLR = Connected Line Identification Restriction
ECT = Explicit call transfer service
MPTY = Multiparty
MCI = Malicious call identification
OS1 up to OS15 = Operator specific 1 to 15

ATTACH ”attach” state of the subscriber (the subscriber is tied to a mobile station)
• SBSTAT output parameter value

BEARS Bearer service. Basic service of support service type


• Symbolic output parameter name
• Parameter value:
BS20 = Data service: asynchronous data circuit (basic service group)
BS21 = Data service: asynchronous data circuit (300 bit/s)
BS22 = Data service: asynchronous data circuit (1200 bit/s)
BS24 = Data service: asynchronous data circuit (2400 bit/s)
BS25 = Data service: asynchronous data circuit (4800 bit/s)
BS26 = Data service: asynchronous data circuit (9600 bit/s)
GBS20 = Data service: asynchronous data circuit (general bearer service)
BS30 = Data service: synchronous data circuit (basic service group)
BS31 = Data service: synchronous data circuit (1200 bit/s)
BS32 = Data service: synchronous data circuit (2400 bit/s)
BS33 = Data service: synchronous data circuit (4800 bit/s)
1AA 00014 0004 (9007) A4 – ALICE 04.10

BS34 = Data service: synchronous data circuit (9600 bit/s)


GBS30 = Data service: synchronous data circuit (general bearer service)
BS40 = Data service: PAD access (Basic service group)

ED 02

3BL 33096 CCAA ADAHA 6 / 60

60
BS41 = Data service: asynchronous PAD access (300 bits/s)
BS42 = Data service: asynchronous PAD access (1200 bits/s)
BS44 = Data service: asynchronous PAD access (2400 bits/s)
BS45 = Data service: asynchronous PAD access (4800 bits/s)
not permitted without written authorization from Alcatel.

BS46 = Data service: asynchronous PAD access (9600 bits/s)


All rights reserved. Passing on and copying of this
document, use and communication of its contents

BS61 = Data service: alternate speech–data (300/9600 bits/s)


BS81 = Data service: speech followed by data (300/9600 bits/s)

BINA (B in A) Substitution of calling identity by first called identity


• Symbolic input and output parameter name
• Parameter value:
Y : Substitution
N : Without substitution (default value)

BOOLVAL System parameter boolean value


• Symbolic input and output parameter name
• Parameter value: TRUE or FALSE

BOTH Fast and slow counters collection


• CLASS input and output parameter value

BOTH AMR codecs used are Full Rate and Half Rate modes
• AMRRATE input and output parameter value

BS Basic Service. Accepted PLMNs management


• Symbolic input parameter name
• Parameter value:
SPEECH = Speech (TS10 basic service group)
TEL = Telephony (TS11 basic service)
TS60 = Facsimile service (basic service group)
FAX61 = Facsimile service (TS61)
FAX62 = Facsimile service (TS62)
BS20 = Data service: asynchronous data circuit (basic service group)
BS21 = Data service: asynchronous data circuit (300 bit/s)
BS22 = Data service: asynchronous data circuit (1200 bit/s)
BS24 = Data service: asynchronous data circuit (2400 bit/s)
BS25 = Data service: asynchronous data circuit (4800 bit/s)
BS26 = Data service: asynchronous data circuit (9600 bit/s)
GBS20 = Data service: asynchronous data circuit (general bearer service)
BS30 = Data service: synchronous data circuit (basic service group)
BS31 = Data service: synchronous data circuit (1200 bit/s)
BS32 = Data service: synchronous data circuit (2400 bit/s)
BS33 = Data service: synchronous data circuit (4800 bit/s)
BS34 = Data service: synchronous data circuit (9600 bit/s)
GBS30 = Data service: synchronous data circuit (general bearer service)
BS40 = Data service: PAD access (Basic service group)
BS41 = Data service: asynchronous PAD access (300 bits/s)
BS42 = Data service: asynchronous PAD access (1200 bits/s)
BS44 = Data service: asynchronous PAD access (2400 bits/s)
BS45 = Data service: asynchronous PAD access (4800 bits/s)
BS46 = Data service: asynchronous PAD access (9600 bits/s)
1AA 00014 0004 (9007) A4 – ALICE 04.10

BS61 = Data service: alternate speech–data (300/9600 bits/s)


BS81 = Data service: speech followed by data (300/9600 bits/s)
ALL = All basic services available in the VLR

ED 02

3BL 33096 CCAA ADAHA 7 / 60

60
BS Basic Service. Accepted PLMNs management
• Symbolic output parameter name
• Parameter value:
SPEECH = Speech (TS10 basic service group)
not permitted without written authorization from Alcatel.

TEL = Telephony (TS11 basic service)


All rights reserved. Passing on and copying of this
document, use and communication of its contents

FAX61 = Facsimile service (TS61)


FAX62 = Facsimile service (TS62)
BS21 = Data service: asynchronous data circuit (300 bit/s)
BS22 = Data service: asynchronous data circuit (1200 bit/s)
BS24 = Data service: asynchronous data circuit (2400 bit/s)
BS25 = Data service: asynchronous data circuit (4800 bit/s)
BS26 = Data service: asynchronous data circuit (9600 bit/s)
GBS20 = Data service: asynchronous data circuit (general bearer service)
BS31 = Data service: synchronous data circuit (1200 bit/s)
BS32 = Data service: synchronous data circuit (2400 bit/s)
BS33 = Data service: synchronous data circuit (4800 bit/s)
BS34 = Data service: synchronous data circuit (9600 bit/s)
GBS30 = Data service: synchronous data circuit (general bearer service)
BS41 = Data service: asynchronous PAD access (300 bits/s)
BS42 = Data service: asynchronous PAD access (1200 bits/s)
BS44 = Data service: asynchronous PAD access (2400 bits/s)
BS45 = Data service: asynchronous PAD access (4800 bits/s)
BS46 = Data service: asynchronous PAD access (9600 bits/s)
BS61 = Data service: alternate speech–data (300/9600 bits/s)
BS81 = Data service: speech followed by data (300/9600 bits/s)

BS Basic Service. Listing of subscribers


• Symbolic input parameter name
• Parameter value:
SPEECH = Speech (TS10 basic service group)
TEL = Telephony (TS11 basic service)
EC = Emergency call (TS12)
SMSMO = Short message originating service
TS60 = Facsimile service (basic service group)
FAX61 = Facsimile service (TS61)
FAX62 = Facsimile service (TS62)
BS20 = Data service: asynchronous data circuit (basic service group)
BS21 = Data service: asynchronous data circuit (300 bit/s)
BS22 = Data service: asynchronous data circuit (1200 bit/s)
BS24 = Data service: asynchronous data circuit (2400 bit/s)
BS25 = Data service: asynchronous data circuit (4800 bit/s)
BS26 = Data service: asynchronous data circuit (9600 bit/s)
GBS20 = Data service: asynchronous data circuit (general bearer service)
BS30 = Data service: synchronous data circuit (basic service group)
BS31 = Data service: synchronous data circuit (1200 bit/s)
BS32 = Data service: synchronous data circuit (2400 bit/s)
BS33 = Data service: synchronous data circuit (4800 bit/s)
BS34 = Data service: synchronous data circuit (9600 bit/s)
GBS30 = Data service: synchronous data circuit (general bearer service)
BS40 = Data service: PAD access (Basic service group)
BS41 = Data service: asynchronous PAD access (300 bits/s)
1AA 00014 0004 (9007) A4 – ALICE 04.10

BS42 = Data service: asynchronous PAD access (1200 bits/s)


BS44 = Data service: asynchronous PAD access (2400 bits/s)
BS45 = Data service: asynchronous PAD access (4800 bits/s)

ED 02

3BL 33096 CCAA ADAHA 8 / 60

60
BS46 = Data service: asynchronous PAD access (9600 bits/s)
BS61 = Data service: alternate speech–data (300/9600 bits/s)
BS81 = Data service: speech followed by data (300/9600 bits/s)
not permitted without written authorization from Alcatel.

BSCDPC Destination point code of the BSC


All rights reserved. Passing on and copying of this
document, use and communication of its contents

• Symbolic input and output parameter name


• Parameter value: from 0 up to 16383 or from 0 up to 16777215 according to the length of the
address used in the network.

BSCNAM BSC name


• Symbolic input and output parameter name
• Parameter value: Up to 8 alphanumeric characters
• Note: RNCNAM and BSCNAM can not have common values

BSCNUM BSC number


• Symbolic input and output parameter name
• Parameter value: from 0 to 99 (50 BSCs maximum)

BSCTYP BSC type


• Symbolic input and output parameter name
• Parameter value: value or list of values with form value: a, or a+b, or a+b+...n
The values not provided in the list have a default value, the default values are only taken in
account for a BSC creation.
Values list:
a = cell identification type
a values:
– CGI : complete identification
– CI : use of CI value (Cell Identification) to identify the cells
– LAC : use of LAC value (Location area code) to identify all the cells within a location area
– LACCI: use of LAC and CI values to identify the cells
– LAI : use of LAI value (Location Area Identification) to identify all the cells within a location
area (Default value)
When ”all LAC/Cells of the PLMN accessible by all BSCs” option is active, only the LAI
value is allowed.
b = management type for ”Hand Over Required Reject” message
b values:
– HORR Management of ”Hand Over Required Reject” message (Default value)
– NOHORR No management of ”Hand Over Required Reject” message
c = management type for ”Classmark Update” message
c values:
– CLMU Management of ”Classmark Update” message (Default value)
– NCLMU No management of ”Classmark Update” message
d = management type for ”Handover Command” message
d values:
– HOCI Management of ”Handover Command” message with cell identification parameter
(Default value)
– NHOCI Management of ”Handover Command” message without the cell identification
parameter
e = management type for ”Confusion” message
e values:
– CONF Management of ”Confusion” message (Default value)
1AA 00014 0004 (9007) A4 – ALICE 04.10

– NCONF No management of ”Confusion” message


f = management type for ”Ciphering Mode Command” message
f values:

ED 02

3BL 33096 CCAA ADAHA 9 / 60

60
– CIMEI Management of ”Ciphering Mode Command” message with IMEI request (Default
value)
– NCIMEI Management of ”Ciphering Mode Command” message without IMEI request
g = management type for ”MSC Invoke Trace” message
not permitted without written authorization from Alcatel.

g values:
All rights reserved. Passing on and copying of this
document, use and communication of its contents

– IVTR Management of ”MSC Invoke Trace” message (Default value)


– NIVTR No management of ”MSC Invoke Trace” message
h = management type for ”Handover Request” message
h values:
– HCAUS Management of parameter ”Cause” in ”Handover Request” message (Default
value)
– NHCAUS Management of ”Handover Request” message without ”Cause” parameter
i = management type for ”Assignment Request” message
i values:
– CLMI2 Management of ”Classmark Info2” parameter in ”Assignment Request” message
(Default value)
– NCLMI2 Management of ”Assignment Request” message without ”Classmark Info2”
parameter
j = management type for ”Unequiped Circuit” message
j values:
– UNEQ Management of ”Unequiped Circuit” message (Default value)
– NUNEQ No management of ”Unequiped Circuit” message
k = Speech transcoder support
k values:
– FR : Full Rate speech version 1 only BSC (Default value)
– DR : Dual rate speech version 1 BSC (1)
– FRMSV : Full Rate only, multi speech version BSC (2)
– DRMSV : Dual rate multi speech version BSC (1)(2)
(1) : Only if option ’Simplified handling of half–rate channel’ is active.
(2) : Only if option ’Speech multi version’ is active.
l = management type for ”Classmark Info3” parameter in ”Handover Request” message
l values:
– CLMI3 Management of ”Handover Request” message with ”Classmark Info3” parameter
(Default value)
– NCLMI3 Management of ”Handover Request” message without ”Classmark Info3” param-
eter
m = Transmission of ”channel needed” parameter in Paging message
m values:
– CHAN Treatment of ”channel needed” parameter in paging message (Default value)
– NCHAN No treatment of ”channel needed” parameter in paging message
n = Transmission of message ”Load Indication” to BSS
n values:
– LDIND Transmission of ”Load Indication” message
– NLDIND No transmission of ”Load Indication” message (Default value)
o = Inclusion of ”Current Channel” IE in ”Handover Request” message to BSS
o values:
– ICCH Including ”Current Channel” IE in ”Handover Request” message
– NICCH Not including ”Current Channel” IE in ”Handover Request” message (Default
value)
p = Truncation of ”Class Mark 2” IE to 4 octets in ”Handover Request” message
1AA 00014 0004 (9007) A4 – ALICE 04.10

p values:
– TCM2 ”Class Mark 2” IE truncated to 4 octets in ”Handover Request” message (Default
value)
– NTCM2 ”Class Mark 2” IE not truncated in ”Handover Request” message

ED 02

3BL 33096 CCAA ADAHA 10 / 60

60
q = Giving the value of the bit 1 of ”downlink DTX” IE in the messages ”Assignment request”
and ”Handover request”
q values:
– DLDTX0 bit 1 of ”downlink DTX” IE set to 0 (the MSC allows the BSS to activate DTX in
not permitted without written authorization from Alcatel.

the downlink direction) in the messages ”Assignment request” and ”Handover request”
All rights reserved. Passing on and copying of this
document, use and communication of its contents

– DLDTX1 bit 1 of ”downlink DTX” IE set to 1 (the MSC forbids the BSS to activate DTX in
the downlink direction) in the messages ”Assignment request” and ”Handover request”
(Default value)
r = Inclusion in the message HO–Request of the parameter ”Old BSS to new BSS information”
r values:
– NIBSSI the parameter ”Old BSS to new BSS information” is not included (Default value)
– IBSSI the parameter ”Old BSS to new BSS information” is included
s = Dual Transfer Mode support
s values:
– DTM the BSC supports DTM mobiles
– Default value is NDTM, the BSC does not support DTM mobiles.

Two other values allow to provide predefined values for BSCTYP:


Value = PHASE1
In this case the following values are defined:
– LAI+HORR+NCLMU+NHOCI+NCONF+NCIMEI+NIVTR+NHCAUS+NCLMI2+NUNEQ+
FR+NCLMI3+NCHAN+NLDIND+NICCH+TCM2+DLDTX1+NIBSSI+NDTM
Value = PHASE2
In this case the following values are defined:
– LAI+HORR+CLMU+HOCI+CONF+CIMEI+IVTR+HCAUS+CLMI2+UNEQ+
DR, FR, FRMSV or
DRMSV+CLMI3+CHAN+LDIND+ICCH+NTCM2+DLDTX1+IBSSI+NDTM
DR is authorized or not depending on an option, PHASE2 takes
the value:
• FR if no option is activated
• DR if the option ’Simplified handling of half–rate channel’ is activated
• FRMSV if option ’Speech multi version’ is is activated
• DRMSV if both options are activated
Default BSCTYP values in creation case:
(a+b+..n) : LAI+HORR+CLMU+HOCI+CONF+CIMEI+IVTR+HCAUS+CLMI2+UNEQ+
FR+CLMI3+CHAN+NLDIND+NICCH+TCM2+DLDTX1+NIBSSI+NDTM

Note 1) The input order of values doesn’t matter (a+n or n+a), only one ”a” and/or ”b” and/or
”n” type value is accepted. In the answer the edited values are always in the a+b+...n order.
Note 2) In the BSC type modification case, only the provided values (a and/or n) will be modified,
the other ones (a and/or n) not provided values stay unmodified.
Note 3) PHASE1 and PHASE2 values are not accepted both. The BSCTYP value may be:
PHASE(1 or 2)+a+...n in this case the values (a to n) provided are in place of the ones defined
by PHASE1 or PHASE2 provided. Example:
BSCTYP=PHASE2+NUNEQ+NIVTR gives the result:
LAI+HORR+CLMU+HOCI+CONF+CIMEI+NIVTR+HCAUS+CLMI2+NUNEQ+
DR, FR, FRMSV or DRMSV+CLMI3+CHAN+LDIND+ICCH+NTCM2+DLDTX1+IBSSI + NDTM
Note 4) In edition the values are on exactly 6 characters, (with filling blanks if necessary).

BS20 Data service: asynchronous data circuit, (basic services group)


• BS input and BEARS and OBSCRI output parameter value
1AA 00014 0004 (9007) A4 – ALICE 04.10

BS21 Data service: asynchronous data circuit (300 bit/s), basic service
• BS input and output and BEARS and OBSCRI output parameter value

ED 02

3BL 33096 CCAA ADAHA 11 / 60

60
BS22 Data service: asynchronous data circuit (1200 bit/s), basic service
• BS input and output and BEARS and OBSCRI output parameter value

BS24 Data service: asynchronous data circuit (2400 bit/s), basic service
not permitted without written authorization from Alcatel.

• BS input and output and BEARS and OBSCRI output parameter value
All rights reserved. Passing on and copying of this
document, use and communication of its contents

BS25 Data service: asynchronous data circuit (4800 bit/s), basic service
• BS input and output and BEARS and OBSCRI output parameter value

BS26 Data service: asynchronous data circuit (9600 bit/s), basic service
• BS input and output and BEARS and OBSCRI output parameter value

BS30 Data service: synchronous data circuit, (basic services group)


• BS input and BEARS and OBSCRI output parameter value

BS31 Data service: synchronous data circuit, 1200 bits/s basic service
• BS input and output and BEARS and OBSCRI output parameter value

BS32 Data service: synchronous data circuit, 2400 bits/s basic service
• BS input and output and BEARS and OBSCRI output parameter value

BS33 Data service: synchronous data circuit (4800 bit/s), basic service
• BS input and output and BEARS and OBSCRI output parameter value

BS34 Data service: synchronous data circuit, 9600 bits/s basic service
• BS input and output and BEARS and OBSCRI output parameter value

BS40 Data service: PAD access (Basic service group)


• BS input and BEARS and OBSCRI output parameter value

BS41 Data service: asynchronous PAD access (300 bits/s)


• BS input and output and BEARS and OBSCRI output parameter value

BS42 Data service: asynchronous PAD access (1200 bits/s)


• BS input and output and BEARS and OBSCRI output parameter value

BS44 Data service: asynchronous PAD access (2400 bits/s)


• BS input and output and BEARS and OBSCRI output parameter value

BS45 Data service: asynchronous PAD access (4800 bits/s)


• BS input and output and BEARS and OBSCRI output parameter value

BS46 Data service: asynchronous PAD access (9600 bits/s)


• BS input and output and BEARS and OBSCRI output parameter value

BS61 Data service: alternate speech–data (300/9600 bits/s)


• BS input and output and BEARS and OBSCRI output parameter value

BS81 Data service: speech followed by data (300/9600 bits/s)


• BS input and output and BEARS and OBSCRI output parameter value

CAMEL CAMEL information , display criterion


• Symbolic input parameter name
• Parameter value: SCP address from 1 up to 15 digits or ALL (any OCSM information)
1AA 00014 0004 (9007) A4 – ALICE 04.10

CAMEL Use of CAMEL services allowed to roamers (accepted PLMN administration)


• Symbolic input and output parameter name
• Parameter value: SCP address from 1 up to 15 digits or ALL (any OCSM information)

ED 02

3BL 33096 CCAA ADAHA 12 / 60

60
Y = Use of CAMEL services allowed, default value at creation time
N = Use of CAMEL services not allowed

CARCHK Check on carrier identification number


not permitted without written authorization from Alcatel.

• ORIG input and output parameter value


All rights reserved. Passing on and copying of this
document, use and communication of its contents

CARRIER Carrier identification


• Symbolic input and output parameter name
• Parameter value with form : type–plan–digit with :
type of network identification
ITU : ITU standardized
NAT : national
network identification plan
0 to 15
network identification digits
1 to 4 digits
• To delete the parameter value : CARRIER=NU–value–value

CAT Category of mobile subscriber


• Symbolic input and output parameter name
• Parameter value:
CAT1 to CAT15 = National category
HB = Hot Billing
ORD = Ordinary

CAT1 to CAT15 National category of mobile subscriber


• CAT and CAX input and output parameters value

CAUSE Causes of ”out of service” state of the SMIM


• Symbolic output parameter name
• Parameter value:
DTRX OR CALX OR CONVERTOR ALARM DETECTED AT INITIALIZATION TIME
SPONTANEOUS DTRX OR CALX OR CONVERTOR ALARM
UNKNOWN CAUSE
MIWX INITIALIZATION FAILURE
MIWX NUMBER n (n= from 1 to 5) INITIALIZATION FAILURE
FAILURE OF AN INTERWORKING CIRCUIT
MIWX FAILURE
OCC FAILURE
RCP FAILURE
MAXIMUM INITIALIZATION DURATION OVERFLOW
ALARM COUNTER THRESHOLD OVERFLOW
WATCH–DOG EXPIRY ON ALARM STATUS ENQUIRY
DISCREPANCY BETWEEN DECLARED MIWX BOARDS AND EQUIPED MIWX BOARDS
MIWX NOT RESPONDING
OUT OF SERVICE SETTING BY THE OPERATOR
MIWX NUMBER n (n= from 1 to 5) NOT DECLARED
MIWX RESTART THRESHOLD IS REACHED
SMIM CREATED WITH AN UNKNOWN DPC OR SMIM POINT CODE STATUS UNKNOWN
SMIM CREATED AND NEVER PUT IN SERVICE
SMIM IS ALREADY IN SERVICE
1AA 00014 0004 (9007) A4 – ALICE 04.10

SMIM DOES NOT EXIST


SMIM IN SERVICE
SMIM ISOLATION OCCURED IN TEST PROCESS

ED 02

3BL 33096 CCAA ADAHA 13 / 60

60
CAX Subscriber category– Charging category
• Symbolic input and output parameter name
• Parameter value with form : a–b with :
a = Subscriber category,
not permitted without written authorization from Alcatel.

CAT1 to CAT15 = national category


All rights reserved. Passing on and copying of this
document, use and communication of its contents

HB = Hot Billing
ORD = Ordinary
b = Charging category
value from 0 to 32 (a zero value means an undefined category)
If a=ORD , b must not be equal to zero).

CBOC Barring of all Outgoing Calls, supplementary service


• ASUPS and SSUPS input and output parameters value
• OPQSS output parameter value

CBOI Barring of all Outgoing International Calls, supplementary service


• ASUPS and SSUPS input and output parameters value
• OPQSS output parameter value

CBOIEXHC Barring of all Outgoing international calls except those directed to the home
PLMN country
• ASUPS and SSUPS input and output parameters value
• OPQSS output parameter value

CC Country Code of the analised number, used by SOR to check the charging
requirements (CC is mandatory when NDCOR is provided)
• Symbolic input and output parameter name
• Parameter value: up to 3 digits,
000 : to delete the parameter value

CCBSA Call Completion on Busy Subscriber, A side


• ASUPS and SSUPS input and output parameters value

CCBSB Call Completion on Busy Subscriber, B side


• ASUPS and SSUPS input and output parameters value

CCBSRQ Analysis of the called number for CCBS request


• ORIG input and output parameters value

CCOMP Call Completion


• APCTX input and output parameters value

CCOTRA Call Control Transfer


• APCTX and RAPCTX input and output parameters value

CD Call Deflection
• SSCSI output parameters value

CELLID Cell Identity


• Symbolic input and output parameter name
• Parameter value: from 0 to 65535
(2048 or 65536 cells maximum per RCP) according to an option)
(512 or 65536 cells maximum per BSC) according to an option)
1AA 00014 0004 (9007) A4 – ALICE 04.10

CFBUSY Call Forwarding on mobile Busy, supplementary service


• ASUPS and SSUPS input and output parameters value

ED 02

3BL 33096 CCAA ADAHA 14 / 60

60
• OPQSS output parameter value

CFNREACH Call Forwarding on mobile Not Reachable, supplementary service


• ASUPS and SSUPS input and output parameters value
not permitted without written authorization from Alcatel.

• OPQSS output parameter value


All rights reserved. Passing on and copying of this
document, use and communication of its contents

CFNREPLY Call Forwarding on No Reply, supplementary service


• ASUPS and SSUPS input and output parameters value
• OPQSS output parameter value

CGAP Call Gaping function (1)


• Symbolic input and output parameter name
• Parameter value:
Y : Call Gaping function offered
N : Call Gaping function not offered (default value)

Note (1) : Only if option ’Call Gaping at RCP’ is offered

CGCAT Charging category


• Symbolic input and output parameter name
• Parameter value:
NOCHG : No charging
CHG : Charging
CHGINT : Charging with international type tariff
CHGINTZ : Charging with inter–zone type tariff
NU : to delete the parameter value

CGI Cell Global Identification managed by BSC


• BSCTYP input and output parameter value

CGPREF Charging prefix


• Symbolic input and output parameter name
• Parameter value: from 1 to 8 digits (0 to 9, A and B)
– value A to code *
– value B to code #
NU to delete the parameter value

CH Call Hold
• ASUPS and SSUPS input and output parameters value

CHAN ”channel needed” handling in Paging message


• BSCTYP input and output parameter value

CHAR Type of requested list for SMIM


• Symbolic input parameter name
• Parameter value:
Y = to list the characteristics and state of SMIM, default value
N = to list the state of SMIM

CHARSTR Character string


• Symbolic input and output parameter name
• Parameter value: String of any 1 to 240 characters
1AA 00014 0004 (9007) A4 – ALICE 04.10

CHG Charging category ”charging”


• CGCAT input and output parameter value

ED 02

3BL 33096 CCAA ADAHA 15 / 60

60
CHGINT Charging category ”charging with international type tariff”
• CGCAT input and output parameter value

CHGINTZ Charging category ”Charging with inter–zone type tariff”


not permitted without written authorization from Alcatel.

• CGCAT input and output parameter value


All rights reserved. Passing on and copying of this
document, use and communication of its contents

CI Cell identification managed by BSC


• BSCTYP input and output parameter value

CIMEI Management by BSC of the ”Ciphering Mode Command” message with IMEI
request
• BSCTYP input and output parameter value

CLASS Observation class of the counters family


• Symbolic input and output parameter name
• Parameter value:
– BOTH : Slow and fast counters collection
– FAST : Fast counters collection
– NONE : No collection of a counters family
– SLOW : Slow counters collection
The MODPER command only accepts SLOW and FAST values.

CLIEC Calling Line Identification analysis for an emergency call


• ORIG input and output parameter value

CLIOC Calling Line Identification analysis for an outgoing call


• ORIG input and output parameter value

CLIOP CLIP/CLIR option


• Symbolic output parameter name
• Parameter value:
For CLIP:
OCE = Override Category Enable
OCN = Override Category Not enable
For CLIR:
PMP = Presentation Mode Permanent (presentation of calling subscriber identification forbid-
den)
PMTPA = Presentation Mode Temporary call by call allowed (presentation of calling subscriber
identification except if for a call the calling subscriber has forbidden it)
PMTPR = Presentation Mode Temporary call by call restricted (no presentation of calling sub-
scriber identification except if for a call the calling subscriber has allowed it)

CLIP Calling Line Identification Presentation


• ASUPS and SSUPS input and output parameters value

CLIR Calling Line Identification Restriction


• ASUPS and SSUPS input and output parameters value

CLITC Calling Line Identification analysis or analysis of the number forwarding the call
or analysis of the call forwarding number for an incoming call or analysis of the
call transfer number for an incoming call
• ORIG input and output parameter value
1AA 00014 0004 (9007) A4 – ALICE 04.10

CLMI2 Management by BSC of parameter ”Classmark Info2” in ”Assignment Request”


message
• BSCTYP input and output parameter value

ED 02

3BL 33096 CCAA ADAHA 16 / 60

60
CLMI3 Management by BSC of parameter ”Classmark Info3” in ”Handover Request”
message
• BSCTYP input and output parameter value
not permitted without written authorization from Alcatel.

CLMU Management by BSC of ”Classmark Update” message


All rights reserved. Passing on and copying of this
document, use and communication of its contents

• BSCTYP input and output parameter value

CODPRE Code of pre–analysis


• Symbolic input and output parameter name
• Parameter value: 4 up to 9 hexadecimal digits

COLOC Connected Line Identification analysis or analysis of the number forwarding the
call or analysis of the call forwarding number for an outgoing call or analysis of
the call transfer number for an outgoing call
• ORIG input and output parameter value

COLOP COLP option


• Symbolic output parameter name
• Parameter value:
OCE = Override category enable
OCN = Override category not enable

COLP Connected Line Identification Presentation


• ASUPS and SSUPS input and output parameters value

COLR Connected Line Identification Restriction


• ASUPS and SSUPS input and output parameters value

COLTC Connected Line Identification analysis for an incoming call


• ORIG input and output parameter value

CONF Management by BSC of ”Confusion” message


• BSCTYP input and output parameter value

CONT Continue the call


• DefCallHDL field value of the OCSM parameter in output

CPTNAME Identification number of the counters family


• Symbolic input and output parameter name
• Parameter value: 5 digits
The counters families existing in RCP and VLR are listed in the operating sheet OPLSTOBS

CRC41 The number of multiframes received with a wrong CRC4 indicates an error bit
rate greater than 10–3 (analysis during 1 s).
• TYPFAU output parameter value

CRC42 The number of multiframes with a wrong CRC4 indicates an error bit rate
greater than 10–6 (analysis during 1 minute).
• TYPFAU output parameter value

CREIND Created dialling code


• Symbolic output parameter name
• Parameter value: from 1 to 31 digits (0 to 9, A and B)
1AA 00014 0004 (9007) A4 – ALICE 04.10

Note that A is used to code * and B to code #

CTCRI Call type criteria allowed to contact the SCP


• Symbolic output parameter name

ED 02

3BL 33096 CCAA ADAHA 17 / 60

60
• Parameter value:
FWD = Forwarding call
OC = Originating call
ALL = Both call types (OC and FWD)
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents

CUGBSG Basic Service Group for Closed Users Group supplementary service
• Symbolic output parameter name
• Parameter value:
SPEECH = Speech transmission
TS60 = Fac simile service
BS20 = data services, duplex asynchronous circuit
BS30 = data services, duplex synchronous circuit

CUGIC CUG interlock code for Closed Users Group


• Symbolic input and output parameter name
• Parameter value: 8 hexadecimal characters

CUGINDX CUG index interlock code for Closed Users Group.


• Symbolic output parameter name
• Parameter value: from 0 to 32767

CUGOPT Intra CUG options (Closed Users Group)


• Symbolic output parameter name
• Parameter value:
NONE = No restrictions
ICB = Incoming Calls Barred within the CUG
OCB = Outgoing Calls Barred within the CUG

CUGPREF Preferential CUG


• Symbolic output parameter name
• Parameter value: from 0 to 32767

CUGRES Inter CUGs (Closed Users Group) restriction


• Symbolic output parameter name
• Parameter value:
NONE = only calls within CUG are allowed
OA = CUG with outgoing access allowed
IA = CUG with incoming access allowed
IOA = CUG with both incoming and outgoing access allowed

CW Call waiting
• ASUPS and SSUPS input and output parameters value
• OPQSS output parameter value

DATAINFO Information display about system parameters


• Symbolic input parameter name
• Parameter value: Y(es) or N(o) (N default value)

DECVAL Decimal value of system parameter


• Symbolic input and output parameter name
• Parameter value: from –231 to +231–1

DEL Number of digits to be deleted


1AA 00014 0004 (9007) A4 – ALICE 04.10

• Symbolic input and output parameter name


• Parameter value: from 1 to 80, 0 to delete the parameter value

ED 02

3BL 33096 CCAA ADAHA 18 / 60

60
DELIND Deleted dialling code
• Symbolic output parameter name
• Parameter value: from 1 to 31 digits (0 to 9, A and B)
Take in account that A is used to code * and B to code #
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents

DETACH ”detach” state of the subscriber (the subscriber is not tied to a mobile station)
• SBSTAT output parameter value

DIGALL First number of the MSRN pool for allocation


• Symbolic input and output parameter name
• Parameter value: from 3 to 16 digits

DIGITAL Digital type SMIM test


• TYPTST output parameter value

DIGITS Digits string


• Symbolic input and output parameter name
• Parameter value: from 1 to 50 digits between 0 and 9

DIGREC First number of the MSRN pool for recognition


• Symbolic input and output parameter name
• Parameter value: from 3 to 16 digits

DLDTX0 Bit 1 of ”downlink DTX” IE set to 0 in the messages ”Assignment request” and
”Handover request”
• BSCTYP input and output parameter value

DLDTX1 Bit 1 of ”downlink DTX” IE set to 1 in the messages ”Assignment request” and
”Handover request”
• BSCTYP input and output parameter value

DNBCRID Disabled Destination number criteria


• Symbolic output parameter name
• Parameter value: Nature of address and Numbering plan on 2 hexadecimal digits followed by
up to 15 digits maximum
Nature of address and Numbering plan:
91 = international E.164
81 = unknown E.164

DNBCRIE Enabled Destination number criteria


• Symbolic output parameter name
• Parameter value: Nature of address and Numbering plan on 2 hexadecimal digits followed by
up to 15 digits maximum
Nature of address and Numbering plan:
91 = international E.164
81 = unknown E.164

DPC Destination point code


• Symbolic input and output parameter name
• Parameter value: from 0 up to 16383 or from 0 up to 16777215 according to the length of the
address used in the network.

DONE Routing number used for portability has been recognised in the analysed
1AA 00014 0004 (9007) A4 – ALICE 04.10

number
• NPDBQ input and output parameter value

ED 02

3BL 33096 CCAA ADAHA 19 / 60

60
DR Dual Rate speech version 1 BSC: assignement of Full Rate or Dual Rate version
1 channel by the BSC.
• BSCTYP input and output parameter value
not permitted without written authorization from Alcatel.

DRMSV Dual Rate multi speech version BSC: assignement of Full Rate or Dual Rate
All rights reserved. Passing on and copying of this
document, use and communication of its contents

multi version channel by the BSC.


• BSCTYP input and output parameter value

DTM Dual Transfer mode


• BSCTYP input and output parameter value

EC Emergency call, basic service


• BS input and TS output parameter value

ECDOFF Echo control device to be disabled on the incoming circuit (1)


• Symbolic input and output parameter name
• Parameter value:
Y : Echo control device to be disabled on the incoming circuit
N : Echo control device not to be disabled on the incoming circuit ( default value )

Note (1) : Only if ’Specific routing for Tandem Free Operation(TFO)’ is offered.

ECT Explicit call transfer


• ASUPS and SSUPS input and output parameter value
• SSCSI output parameter value

EMER Indication of emergency service


• Symbolic input and output parameter name
• Parameter value:
Y : Calling number of an emergency service
N : Other numbering (default value)

ENTLOC Distant entity in HPLMN


• Symbolic input and output parameter name
• Parameter value:
INTRA : intra–PLMN MAP version used to dialogue with a distant entity ( default value )
INTER : inter–PLMN MAP version used to dialogue with a distant entity

ERR1 The error bit rate has reached 10–3 (count during 1 second the errors in the
frame alignment signal)
• TYPFAU output parameter value

ERR2 The error bit rate has reached 10–5 (count during 1 minute the errors in the
frame alignment signal)
• TYPFAU output parameter value

EXT Problem is external to the reception trunk of the DTRX board


• TYPFAU output parameter value

E1 Number of units (expressed in 1/10) of local PLMN by time interval


• Symbolic input and output parameter name
• Parameter value: from 0 to 8191
1AA 00014 0004 (9007) A4 – ALICE 04.10

E2 Time interval to compute units (1/10 of second)


• Symbolic input and output parameter name
• Parameter value: from 0 to 8191

ED 02

3BL 33096 CCAA ADAHA 20 / 60

60
E3 Conversion factor (expressed in 1/100) between the units of the HPLMN and
the LPLMN
• Symbolic input and output parameter name
• Parameter value: from 0 to 8191
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents

E4 Number of units (expressed in 1/10) to be incremented by the mobile after


receiving the ”Forward Charge Advice” message
• Symbolic input and output parameter name
• Parameter value: from 0 to 8191

E7 First time interval to compute units (1/10 of second)


• Symbolic input and output parameter name
• Parameter value: from 0 to 8191

E164 Numbering plan ISDN E164


• NUMPL input and output parameter value

E212 Numbering plan E212


• NUMPL input and output parameter value

FAST Fast counters collection


• CLASS input and output parameter value

FAU MIWX in fault


• Status field value of MIWXST parameter in output

FAX61 Facsimile group3, basic service


• BS input and TS and OBSCRI output parameter value

FAX62 Automatic Facsimile group3, basic service


• BS input and TS and OBSCRI output parameter value

FR Full Rate speech version 1 only BSC: assignement of Full Rate version 1 chan-
nel by the BSC
• BSCTYP input and output parameter value

FR Full Rate preferred when both rates are used


• AMRPRATE input and output parameter value

FR AMR codecs are only used in Full Rate, if supported by the MS


• AMRRATE input and output parameter value

FRMSV Full Rate multi speech version BSC: assignement of Full Rate multi version
channel by the BSC
• BSCTYP input and output parameter value

FTNINT Forwarded–to–Number analysis for interrogation


• ORIG input and output parameter value

FWD Forwarded call (CAMEL)


• CTCRI output parameter value

FWNB Forwarded–to number


• Symbolic output parameter name
1AA 00014 0004 (9007) A4 – ALICE 04.10

• Parameter value: MSISDN, 15 digits maximum number.

FWVA Forwarding violation allowed

ED 02

3BL 33096 CCAA ADAHA 21 / 60

60
• Symbolic input and output parameter name
• Parameter value:
Y = Forwarding violation allowed (only if the corresponding option is offered)
N = Forwarding violation not allowed (default value)
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents

GAN Geographical area number for a group of cells in GSM environment or service
area in UMTS environment
• Symbolic input and output parameter name
• Parameter value: from 1 to 255
– up to 64 when the SSP type is an E10MT
– up to 127 when the SSP type is an E10B
– up to 255 when the SSP type is an OCB283

GANTR Transmission or not of the geographical area to SSP


• Symbolic input and output parameter name
• Parameter value:
Y : Geographical area transmitted
N : Geographical area not transmitted (default value)

GBS20 Data service: asynchronous data circuit, (general bearer service)


• BS input and BEARS and OBSCRI output parameter value

GBS30 Data service: synchronous data circuit, (general bearer service)


• BS input and BEARS and OBSCRI output parameter value

GMSCFW Forwarded–to number from a MSC gateway


• ORIG input and output parameter value

HB Hot Billing, subscriber category


• CAT and CAX input and output parameters value

HCAUS Management by BSC of ”Cause” parameter in ”Handover Request” message


• BSCTYP input and output parameter value

HDB3 Excessive error rate in the HDB3 coding received


• TYPFAU output parameter value

HEXVAL Hexadecimal value of system parameter


• Symbolic input and output parameter name
• Parameter value: from 0 to FFFFFFFF

HEXSTR Hexadecimal string value of system parameter


• Symbolic input and output parameter name
• Parameter value: from 2 up to 32 hexadecimal characters string with an even number of charac-
ters

HLRCNF Indicator of HLR confirmation for subscribers data


• Symbolic output parameter name
• Parameter value: Y or N

HLRNB HLR number


• Symbolic input and output parameter name
• Parameter value: ISDN, number from 6 to 15 digits maximum
1AA 00014 0004 (9007) A4 – ALICE 04.10

HLRNB Sort type by HLRNB


• SORT input parameter value

ED 02

3BL 33096 CCAA ADAHA 22 / 60

60
HLRROUT HLR request (type of result)
• TYPE input and output parameter value

HLRRST HLR reset (location register restart)


not permitted without written authorization from Alcatel.

• RAPCTX input and output parameter value


All rights reserved. Passing on and copying of this
document, use and communication of its contents

HOCI Management by BSC of target cell identification parameter of the ”Handover


Command” message
• BSCTYP input and output parameter value

HORR Management by BSC of ”Hand Over Required Reject” message


• BSCTYP input and output parameter value

HPLMN Home PLMN


• PLMN input and output parameter value

HR Half Rate preferred when both rates are used


• AMRPRATE input and output parameter value

HR AMR codecs are only used in Half Rate mode, if supported by the MS
• AMRRATE input and output parameter value

IA Incoming calls allowed for the CUG


• CUGRES output parameter value

IBSSI Inclusion in the message HO–Request of the parameter ”Old BSS to new BSS
information”
• BSCTYP input and output parameter value

IC Call indication considered as international for the ”barring”


• Symbolic input and output parameter name
• Parameter value:
Y : Call considered as international
N : Call considered as not international
NU : Deletion of the parameter value (in input)
• If the parameter is not provided, the call is characterized by the numbering type

ICB Incoming Calls Barred within the CUG


• CUGOPT output parameter value

ICCH Including ”Current Channel” IE in ”Handover Request” message


• BSCTYP input and output parameter value

IMEI International Mobile Equipment Identification


• NUMPL input and output parameter value

IMSI IMSI analysis


• ANA input and output parameter value

IMSI IMSI sort type


• SORT input parameter value

IMSI International Mobile Subscriber Identity


• Symbolic input and output parameter name
1AA 00014 0004 (9007) A4 – ALICE 04.10

• Output parameter value: form value MCC–MNC–MSIN with:


MCC = Mobile Country Code: 3 digits
MNC = Mobile Network Code: 2 or 3 digits

ED 02

3BL 33096 CCAA ADAHA 23 / 60

60
MSIN= Mobile Subscriber Identification Number: from 4 to 9 or 10 digits according to the num-
bering plan.
• Input parameter value: in input the IMSI parameter is not segmented. Moreover it may be trun-
cated on right in order to indicate an IMSI group signalled by their first digits. When this input
not permitted without written authorization from Alcatel.

mode is authorized, it’s indicated in the operator sheets.


All rights reserved. Passing on and copying of this
document, use and communication of its contents

IN SMIM or MIWX in service


• Symbolic input and output STATE parameter value
• Status field value of MIWXST parameter in output

IND Dialling number to be analysed in the translator


• Symbolic input and output parameter name
• Parameter value: from 1 to 20 or 1 to 31 digits (0 to 9, A and B), on ption
– value A to code *
– value B to code #

INFAL Fault information


• Symbolic output parameter name
• Parameter value:
NO FAULT
FAULT(S) ON DTRX BOARD
FAULT(S) ON CALX BOARD
FAULT ON CONVERTOR
OBC FAULT(S) ON MIWX n BOARD (board number n= 1 to 5)
OCC FAULT(S) ON MIWX n BOARD (board number n= 1 to 5)

INFO Information about the system parameter


• Symbolic output parameter name
• lines of text describing the parameter use

INFRET Information retrieval


• APCTX input and output parameter value

INHCB Override of all call barring types


• Symbolic input and output parameter name
• Parameter value:
Y : Override allowed
N : Override not allowed (default value)

INIMSI Rank of digit and number of digits of IMSI to be inserted


• Symbolic input and output parameter name
• Parameter value: rk–nb
rk : absolute rank between 1 and 20
nb : between 1 and 20
0 for nb to delete the parameter value

INIS SMIM in service but isolated


• STATE output parameter value

INIT Initialization of SMIM is running


• STATE output parameter value

INITFAIL Initialisation failure during SMIM tests


1AA 00014 0004 (9007) A4 – ALICE 04.10

• OBCFAU output parameter value

INS Rank of digit and number of digits of the additional number to be inserted

ED 02

3BL 33096 CCAA ADAHA 24 / 60

60
• Symbolic input and output parameter name
• Parameter value: rk–nb
rk : absolute rank between 1 and 20
nb : between 1 and 20
not permitted without written authorization from Alcatel.

0 for nb to delete the parameter value


All rights reserved. Passing on and copying of this
document, use and communication of its contents

INSLAC Rank of the digit (rk) and number of digits (nb) of the location to be inserted.
• Symbolic input and output parameter name
• Parameter value: rk–nb
rk : absolute rank from 1 to 10 depending on option, or from 1 to 16 depending on option
nb : from 1 to 10
with rk+nb less than or equal to 11 depending on option, or 17 depending on option
0 for nb to delete the parameter value

INT Problem detected in the reception trunk of the DTRX board


• TYPFAU output parameter value

INTCS International with carrier selection


• NUMTYP input and output parameter value

INTE International
• NUMTYP input and output parameter value

INTER MSRNs pool for foreign mobile


• ROAMTYP input and output parameter value

INTER Inter–PLMN MAP version


• ENTLOC input and output parameter value

INTRA MSRNs pool for national mobile


• ROAMTYP input and output parameter value

INTRA Intra–network type of number


• NUMTYP input and output parameter value

INTRA Intra–PLMN MAP version


• ENTLOC input and output parameter value

INTRACS Intra–network numbering with carrier selection


• NUMTYP input and output parameter value

IOA All the terminating and outgoing calls authorized for CUG
• CUGRES output parameter value

IPAD Loss of clock reference signal from DTRX board


• TYPFAU output parameter value

ISDN ISDN sort type


• SORT input parameter value

ISDNNB ISDN number of ISDN address


• Symbolic input and output parameter name
• Parameter value: 1 up to 16 digits between 0 and 9
1AA 00014 0004 (9007) A4 – ALICE 04.10

IVTR Management by BSC of the ”Invoke Trace” message


• BSCTYP input and output parameter value

ED 02

3BL 33096 CCAA ADAHA 25 / 60

60
IWFTYP Inter Working Function type
• Symbolic input and output parameter name
• Parameter value: SPEECH, IWF1, IWF2, IWF3, IWF4
not permitted without written authorization from Alcatel.

IWF1 up to 4 Inter Working Function 1 to 4


All rights reserved. Passing on and copying of this
document, use and communication of its contents

• IWFTYP input and output parameter value

IWSCADD SC address received from MSC in SMS–IWMSC


• ORIG input and output parameter value

LAC Location Area Code


• Symbolic input and output parameter name
• Parameter value: value or list of values from 1 to 65533
(256 or 4096 local LACs maximum per RCF, according to an option)
(128 or 1024 adjacent LACs maximum for adjacent VLRs, according to an option)
(128 or 1024 adjacent LACs maximum for adjacent MSCs, according to an option)
• If the 0 value is authorized, it’s indicated in the operator sheet.
• When ”previous VLR determination using MSC identity” option is active, the LAC parameter
must be one value from 0 up to 63

LAC Location Area Code, management by BSC / RNC of LAC value, to identify all
the cells or service areas within a location area.
• BSCTYP / RNCTYP input and output parameter value

LACCI Management by BSC of LAC and CI values, to identify the cells.


• BSCTYP input and output parameter value

LACNRA Current LAC allowed for national roaming


• Symbolic output parameter name
• Parameter value: Y or N

LACRSA Current LAC allowed for regional subscription


• Symbolic output parameter name
• Parameter value: Y or N

LACSUP Lac deletion allowed or not allowed


• Symbolic input and output parameter name
• Parameter value: Y or N
• Default value depends on an option:
– Y : if the option is not active
– N : if the option is active

LACTR Information LAC + CI ( in GSM ) or LAC + SAC ( in UMTS ) transmitted or not


to SSP
• Symbolic input and output parameter name
• Parameter value:
Y : LAC + CI ( in GSM ) transmitted (allowed value if the corresponding option is offered), or
Y : LAC + SAC ( in UMTS ) transmitted (allowed value if the corresponding option is offered)
N : LAC + CI not transmitted (default value) , or
N : LAC + SAC ( in UMTS ) not transmitted (default value)

LAI Location Area Identification, management by BSC of LAI value, to identify all
the cells within a location area.
1AA 00014 0004 (9007) A4 – ALICE 04.10

• BSCTYP input and output parameter value

ED 02

3BL 33096 CCAA ADAHA 26 / 60

60
LATIT Latitude of the cell centre (in GSM environment), or of a service area (in UMTS
environment)
• Symbolic input and output parameter name
• Parameter value: Value with format: degrees–mn–sec–hundreth–direction with:
not permitted without written authorization from Alcatel.

Degrees = from 0 to 90
All rights reserved. Passing on and copying of this
document, use and communication of its contents

Minutes = from 0 to 59
Seconds = from 00 to 59
Hundreth = from 00 to 99
Direction= N (North) or S (South)

LCKNB Lock Number, Number of subscribers with locked data, to forbid them the
access.
• Symbolic output parameter name.
Parameter value: Integer in decimal numbering.

LDIND Transmission of ”Load Indication” message by the BSC


• BSCTYP input and output parameter value

LEN Numbering length analysis


• ANA input and output parameter value

LENGTH Result depending on the length (type of result)


• TYPE input and output parameter value

LFA Loss of frame alignment on the PCM link


• TYPFAU output parameter value

LGCRID Length of the destination number criteria disabled


• Symbolic output parameter name
• Parameter value: 1 or 2 digits

LGCRIE Length of the destination number criteria anabled


• Symbolic output parameter name
• Parameter value: 1 or 2 digits

LGPOOL Length of the MSRNs pool


• Symbolic input and output parameter name
• Parameter value: from 10 to 1000

LINKRES Result linked with HLR interrogation result


• Symbolic input and output parameter name
• Parameter value: from 1 to 4000 or from 1 to 12000 on option

LIS Loss of incoming signal on the DTRX board


• TYPFAU output parameter value

LISTA List of results according to the access type ( GSM or UMTS )


• Symbolic input and output parameter name
• Parameter value: list of 2 results (related to the type of access GSM / UMTS ) with a value of
1 to 12000 decimal.
The list may not contain results which are themselves results of type ACCESS

LISTL List of analysis results depending on length


1AA 00014 0004 (9007) A4 – ALICE 04.10

• Symbolic input and output parameter name


• Parameter value: list from 1 to 21 couples with form length–result
length from 1 to 21

ED 02

3BL 33096 CCAA ADAHA 27 / 60

60
the result associated to length 21 deals for all lengths in the range 21 to 80.
result from 1 to 4000 or from 1 to 12000 according to an option
To remove a value (length–result) from the list, LISTL=length–0 must be entered.
not permitted without written authorization from Alcatel.

LKF The signalling link (TS16) is out of service


All rights reserved. Passing on and copying of this
document, use and communication of its contents

• TYPFAU output parameter value

LOC Transmission or not of a location number to SSP


• Symbolic input and output parameter name
• Parameter value:
Y : Location transmitted
N : Location not transmitted
• If the parameter is not provided, its value is given by a system parameter.

LOCCAN Location cancel


• RAPCTX input and output parameter value

LOCNB Location cell address (in GSM environment), or of a service area (in UMTS
environment)
• Symbolic input parameter name
• Parameter value: 15 digits maximum (format E164)
The default value is either the MSC E164 address or the value of PLMN parameter LOCNB–
DEF depending on a functional option.

LOCRET Location information retrieval


• APCTX input and output parameter value

LOCUPD Location update


• APCTX input and output parameter value

LONGIT Longitude of the cell centre (in GSM environment), or of a service area (in UMTS
environment)
• Symbolic input and output parameter name
• Parameter value: Value with format: degrees–mn–sec–hundreth–direction with:
Degrees = from 0 to 180
Minutes = from 0 to 59
Seconds = from 00 to 59
Hundreth = from 00 to 99
Direction= E (East) or W (West)

LOOPANA Loop to another translator (type of result)


• TYPE input and output parameter value

LOOPPREA Loop to preanalysis (type of result)


• TYPE input and output parameter value

LSTPAR Parameters list option for analysis results


• Symbolic input parameter name
• Parameter value:
Y : Display of parameters list for analysis results (default value)
N : No display of parameters list for analysis results

LSTSERV Subscribers data listing type


1AA 00014 0004 (9007) A4 – ALICE 04.10

• Symbolic input parameter name


• Parameter value:
Y = to list IMSI, MSISDN, HLRNB, basic services and supplementary services (default value)

ED 02

3BL 33096 CCAA ADAHA 28 / 60

60
N = to list IMSI, MSISDN and HLRNB

MAC The CALX board did not acknowledge the DTRX alarm report (the reinitializa-
tion of the CALX board is probably in progress)
not permitted without written authorization from Alcatel.

• TYPFAU output parameter value


All rights reserved. Passing on and copying of this
document, use and communication of its contents

MAPHONB Handover number in a controlling MSC


• ORIG input and output parameter value

MAPKEY Dialling code or remote identity number


• Symbolic input and output parameter name
• Parameter value: 15 digits maximum, 0 to delete the parameter value

MAPMSRN Translator call in MSC gateway with a MSRN from HLR


• ORIG input and output parameter value

MAPVERS MAP version key (type of result)


• TYPE input and output parameter value

MAX Maximum length of current analyzed number


• Symbolic input and output parameter name
• Parameter value: from 0 to 80, 0 to delete the parameter value

MCC Mobile country code. Country dialling code E212


• Symbolic input and output parameter name
• Parameter value: 3 digits (from 0 to 9), 000 to delete the parameter value

MCI Malicious Calls Identification


• ASUPS input and output parameter value
• SSUPS input and output parameter value

MIMASS Name of associated SMIM


• Symbolic input and output parameter name
• Parameter value: Up to 8 alphanumeric characters

MIMCIC Pool base CIC assigned to the SMIM


• Symbolic input and output parameter name
• Parameter value: multiple of 32 from 0 to 4064

MIMDPC Destination point code of the SMIM


• Symbolic input and output parameter name
• Parameter value: from 0 up to 16383 or from 0 up to 16777215 according to the length of the
address used in the network.

MIMNAM Name of the Standalone Mobile Interworking Module (SMIM)


• Symbolic input and output parameter name
• Parameter value: Up to 8 alphanumeric characters

MIN Minimum length of current analyzed number


• Symbolic input and output parameter name
• Parameter value: from 0 to 80, 0 to delete the parameter value

MIWX MIWX board number



1AA 00014 0004 (9007) A4 – ALICE 04.10

Symbolic input and output parameter name


• Parameter value: from 1 to 5

MIWXST MIWX board status

ED 02

3BL 33096 CCAA ADAHA 29 / 60

60
• Symbolic output parameter name
• Parameter value: value of format: number–status with:
Number= MIWX board number
Status= MIWX board status:
not permitted without written authorization from Alcatel.

FAU : MIWX board in fault


All rights reserved. Passing on and copying of this
document, use and communication of its contents

IN : MIWX board in service


OUT : MIWX board out of service

MMC Problem on the MMC interface of the CALX board


• TYPFAU output parameter value

MOBILE Number asked by a mobile subscriber (outgoing call)


• ORIG input and output parameter value

MODIND Dialling code with modified result


• Symbolic output parameter name
• Parameter value: 1 to 31 digits (from 0 to 9, A and B)
Note that A is used to code * and B to code #

MPTY Multiparty
• ASUPS input and output parameter value
• SSUPS input and output parameter value
• SSCSI output parameter value

MS MS choice for rate and speech versions is kept unchanged


• AMRRATE input and output parameter value

MSCGA Global address of the adjacent MSC


• Symbolic input and output parameter name
• Parameter value: from 1 to 999999999999999 (maximum 15 digits), with international format

MSCNAM Adjacent MSC name


• Symbolic input and output parameter name
• Parameter value: Up to 8 alphanumeric characters

MSDATA Subscriber known in VLR data base


• Symbolic output parameter name
• Parameter value: Y or N

MSISDN International MS ISDN Number in directory for a mobile subscriber


• Symbolic input and output parameter name
• Output parameter value: Up to 15 digits with the following format:
CC = Country code
NDC = National Destination code
SN = Subscriber Number
• Input parameter value: the input parameter takes the value of the output one but it may be trun-
cated on right to indicate a MSISDNs group signalled by their first digits. When this input mode
is authorized, it’s indicated in the operator sheets.

MSISDNI Indicates the analysed number is an MSISDN of the HPLMN


• Symbolic input and output parameter name
• Parameter value: Y or N (default value = N)
1AA 00014 0004 (9007) A4 – ALICE 04.10

MSNB Mobile subscriber number, number of mobile subscribers


• Symbolic output parameter name
• Parameter value: Integer in decimal numbering

ED 02

3BL 33096 CCAA ADAHA 30 / 60

60
MSPURG Mobile station purging
• APCTX input and output parameter value

MSR The DTRX board does not send any more alarm report to the CALX board
not permitted without written authorization from Alcatel.

(DTRX board is probably in a phase of reinitialization)


All rights reserved. Passing on and copying of this
document, use and communication of its contents

• TYPFAU output parameter value

NATCS National with carrier selection


• NUMTYP input and output parameter value

NATIO National
• ADDNAT input and output parameter value
• NID input and output parameter value
• NUMPL input and output parameter value
• NUMTYP input and output parameter value

NCGZ Cell charging zone code


• Symbolic input parameter name
• Parameter value: from 1 to 128
A default value is initialized (the value depends on PLMN)

NCHAN No treatment per BSC of ”channel needed” in paging message


• BSCTYP input and output parameter value

NCIMEI Management by BSC of the ”Ciphering Mode Command” message without


IMEI request
• BSCTYP input and output parameter value

NCLMI2 Management by BSC of the ”Assignment Request” message without the


”Classmark Info2” parameter
• BSCTYP input and output parameter value

NCLMI3 Management by BSC of the ”Handover Request” message without the ”Class-
mark Info3” parameter
• BSCTYP input and output parameter value

NCLMU No management by BSC of the ”Classmark Update” message


• BSCTYP input and output parameter value

NCONF No management by BSC of the ”Confusion” message


• BSCTYP input and output parameter value

NDCOR National Destination Code of the analised number, used by SOR function to
check the charging requirements (the parameter CC must be provided in this
case)
• Symbolic input and output parameter name
• Parameter value: up to 4 digits (0 to 9), 0000 value to delete the parameter value

NDTM No support by BSC of Dual Transfer Mode Mobiles


• BSCTYP input and output parameter value.

NETWORK Number coming from RTC (incoming call received by the gateway)
• ORIG input and output parameter value
1AA 00014 0004 (9007) A4 – ALICE 04.10

NHCAUS Management by BSC of the ”Handover Request” message without the ”Cause”
parameter
• BSCTYP input and output parameter value

ED 02

3BL 33096 CCAA ADAHA 31 / 60

60
NHOCI Management by BSC of the ”Handover Command” message without the identi-
fication parameter of the target cell
• BSCTYP input and output parameter value
not permitted without written authorization from Alcatel.

NIBSSI Not inclusion in the message HO–Request of the parameter ”Old BSS to new
All rights reserved. Passing on and copying of this
document, use and communication of its contents

BSS information”
• BSCTYP input and output parameter value

NICCH Not including ”Current Channel” IE in ”Handover Request” message (Default


value)
• BSCTYP input and output parameter value

NID Type of nº7 address


• Symbolic input and output parameter name
• Parameter value: NATIO, INTE, LOC

NIVTR No management by BSC of the ”Invoke Trace” message


• BSCTYP input and output parameter value

NLDIND No transmission per BSC of ”Load Indication” message (Default value)


• BSCTYP input and output parameter value

NO The analysed number does not match a call charging type with special tariff
(Premium Rate)
• PRMRATE input and output parameter value

NOCHG No charged charging category


• CGCAT input and output parameter value

NOF Indication of barring for a call routing after a call forwarding


• Symbolic input and output parameter name
• Parameter value:
Y : Barring
N : No barring (default value)

NOHORR No management per BSC of ”Hand Over Required Reject” message


• BSCTYP input and output parameter value

NONE No restrictions for CUG


• CUGOPT output parameter value

NONE The only authorized calls are within the CUG


• CUGRES output parameter value

NONE No collection of the counters of a family


• CLASS input and output parameter value

NONE The BSC does not support AMR


• AMRRATE input and output parameter value

NOS Indication of numeration forbidden to subscribers


• Symbolic input and output parameter name
• Parameter value:
1AA 00014 0004 (9007) A4 – ALICE 04.10

Y : Numeration forbidden
N : Numeration not forbidden (default value)

NPDBQ Numbering Portability Date Base Query (1)

ED 02

3BL 33096 CCAA ADAHA 32 / 60

60
• Symbolic input and output parameter name
• Parameter value:
DONE : A NPDB query has already been done in an upstream exchange,
this value is set when a routing number used for portability has been
not permitted without written authorization from Alcatel.

recognised in the analysed number


All rights reserved. Passing on and copying of this
document, use and communication of its contents

N : No information (default value)

Note (1) Only if option ’Mobile Number Portability’ is offered.

NPNA Numbering plan and nature of address for a Non–E.164 forwarded_to number
• Symbolic output parameter name
• Parameter value: 2 hexadecimal characters

NSUP Application context not supported by the foreign network


• VERSION and RVERSION input and output parameters value

NTCM2 ”Class Mark 2” IE not truncated in ”Handover Request” message


• BSCTYP input and output parameter value

NU Value given to a parameter to delete its value


• Parameter value: ADD, CGCAT, CGPREF, IC, NUMPL, NUMTYP, OBSEMER, OBSRES,
ORIG, ORIGCDS, PLMN, PMRATE, SUBPROF in input

NUM The current numeration analysis


• ANA input and output parameter value

NUMPL Numbering plan


• Symbolic input and output parameter name
• Parameter value:
E164 = Numbering plan ISDN E164
E212 = Numbering plan E212
NATIO = Numbering plan national
PRIV = Numbering plan private
UKN = Numbering plan unknown
IMEI = Numbering plan IMEI (International Mobile Equipement Identification)
NU = Deletion of the parameter value (for MODTRR) (in input only)
Default value = E164 (for MODPRE and DELPRE)

NUMTYP Numeration type


• Symbolic input and output parameter name
• Parameter value:
INTE = International numeration
NATIO = National numeration
SPS = Special service (for routing to SSP only)
SN = Subscriber number
TRSGRP = Transgroup numbering
UKN = Unknown numeration type
PAD = Short number for a dedicated PAD access
INTRA = Intra–network type of number
INTCS = International with carrier selection
NATCS = National with carrier selection
INTRACS = Intra–network numbering with carrier selection
1AA 00014 0004 (9007) A4 – ALICE 04.10

RES1 to RES4 = Reseved values 1 to 4 for national use


NU = Deletion of the parameter value (for MODTRR) (in input only)
RNCDN = Network routing number concatenated with called directory number

ED 02

3BL 33096 CCAA ADAHA 33 / 60

60
RNNAT = Network routing number in national number format
RNSPE = Network routing number in network–specific number format

NUNEQ No management by BSC of the ”Unequipped Circuit” message


not permitted without written authorization from Alcatel.

• BSCTYP input and output parameter value


All rights reserved. Passing on and copying of this
document, use and communication of its contents

NWFSSH Network functional supplementary services handling


• APCTX input and output parameter value

NWUSSH Network unstructured supplementary services handling


• APCTX and RAPCTX input and output parameters value

OA Outgoing Access from CUG allowed


• CUGRES output parameter value

OBCERR List of fast tests which have failed


• Symbolic output parameter name
• Parameter value:
OBCI = OBCI test
OCC = OCC test
PTT = Periodic timer test
RAM = RAM test
STT = Sanity timer test
WPR = Memory write protection test

OBCFAU Failure of the OBC of a MIWX board


• Symbolic output parameter name
• Parameter value:
RESTART = restart
TIMEOUT = timer expiry
INITFAIL = initialisation failure
UNMSGR = unexpected message received

OBCI Failure of OBCI fast test


• OBCERR output parameter value

OBSCRI Basic Services allowed to contact the SCP


• Symbolic output parameter name
• Parameter value:
SPEECH = Speech (TS10 basic service group)
TEL = Telephony (TS11 basic service)
TS60 = Facsimile service (basic service group)
FAX61 = Facsimile service (TS61)
FAX62 = Facsimile service (TS62)
BS20 = Data service: asynchronous data circuit (basic service group)
BS21 = Data service: asynchronous data circuit (300 bit/s)
BS22 = Data service: asynchronous data circuit (1200 bit/s)
BS24 = Data service: asynchronous data circuit (2400 bit/s)
BS25 = Data service: asynchronous data circuit (4800 bit/s)
BS26 = Data service: asynchronous data circuit (9600 bit/s)
GBS20 = Data service: asynchronous data circuit (general bearer service)
BS30 = Data service: synchronous data circuit (basic service group)
1AA 00014 0004 (9007) A4 – ALICE 04.10

BS31 = Data service: synchronous data circuit (1200 bit/s)


BS32 = Data service: synchronous data circuit (2400 bit/s)
BS33 = Data service: synchronous data circuit (4800 bit/s)
BS34 = Data service: synchronous data circuit (9600 bit/s)

ED 02

3BL 33096 CCAA ADAHA 34 / 60

60
GBS30 = Data service: synchronous data circuit (general bearer service)
BS40 = Data service: PAD access (Basic service group)
BS41 = Data service: asynchronous PAD access (300 bits/s)
BS42 = Data service: asynchronous PAD access (1200 bits/s)
not permitted without written authorization from Alcatel.

BS44 = Data service: asynchronous PAD access (2400 bits/s)


All rights reserved. Passing on and copying of this
document, use and communication of its contents

BS45 = Data service: asynchronous PAD access (4800 bits/s)


BS46 = Data service: asynchronous PAD access (9600 bits/s)
BS61 = Data service: alternate speech–data (300/9600 bits/s)
BS81 = Data service: speech followed by data (300/9600 bits/s)

OBSEMER Identification of an emergency service having to be observed


• Symbolic input and output parameter name
• Parameter value: from 1 to 8 alphanumeric characters, NU to delete the parameter value

OBSRES Identification of an analysis result having to be observed


• Symbolic input and output parameter name
• Parameter value: from 1 to 8 alphanumeric characters
NU to delete the parameter value

OC Outgoing Calls (CAMEL)


• CTCRI output parameter value

OCB Outgoing Calls Barred within the CUG


• CUGOPT output parameter value

OCC Failure of OCC fast test


• OBCERR output parameter value

OCCERR OCC error (only used by manufacturer)


• Symbolic output parameter name
• Parameter value:
NONE
FIFO UNDERRUN
FIFO OVERRUN
OCC NOT RESPONDING
FAST TEST FAILED
RESET FAILED
INTERNAL FAILURE
INTERNAL DATA FAILURE
ILLEGAL RESET
SYNC FAILED 10 TIMES SUCCESSIVELY

OCCNB OCC numbers (On board channel controller)


• Symbolic output parameter name
• Parameter value: 0 to 5

OCCRES OCC result (only used by manufacturer)


• Symbolic output parameter name
• Parameter value:
SUCCESSFUL (rigth answer of the SMIM on RCP request)
MESSAGE NOT IN SEQUENCE
WRONG MESSAGE PARAMETER
1AA 00014 0004 (9007) A4 – ALICE 04.10

OCC NOT RESPONDING


FAST TEST FAILED
OTHER OCC ERROR
PATTERN FAULTY

ED 02

3BL 33096 CCAA ADAHA 35 / 60

60
NO APPLICATION PROCEDURE
COUT PORT WRITE FAILURE

OCE Override Category Enable


not permitted without written authorization from Alcatel.

• CLIOP output parameter value


All rights reserved. Passing on and copying of this
document, use and communication of its contents

• COLOP output parameter value

OCN Override Category Not enable


• CLIOP output parameter value
• COLOP output parameter value

OCPBHDL = CAMEL Capability Handling for Mobile Originating Call


• Symbolic output parameter name
• Parameter value:
1= CAMEL phase 1
2= CAMEL phase 2

OCSM = CAMEL service for outgoing call


• Symbolic output parameter name
• Parameter value: value with format SKC–SCPAddress–DefCallHDL with:
SKC= CAMEL service key: integer between 0 and 2147483647 (231–1)
SCPAddress= SCP address: 15 digits maximum
DefCallHDL= Call handling in error case
REL = release the call
CONT= continue the call

ODBCAT = Operator Determined Barring Category


• Symbolic output parameter name
• Parameter value:
ODBCT Barring of invocation of call transfer
ODBCTC Barring of invocation of call transfer where at least one of the two calls is a call charged
to the served subscriber
ODBCTDC Barring of invocation of explicite call transfer doubly chargeable
ODBCTI Barring of invocation of call transfer where at least one of the two calls is a call charged
to the served subscriber at international rate, namely the call charged is either an ougoing
international call or an incoming call when the served subscriber roams outside the PLMN coun-
try
ODBCTM Barring of multiple invocation of explicite call transfer
ODBCTZ Barring of invocation of call transfer where at least one of the two calls is a call charged
to the served subscriber at inter–zone rate, namely the call is either an outgoing inter–zone call
or an incoming call when the served subcriber roams in a VPLMN in a zone different from the
HPLMN
ODBOC Barring of all outgoing calls
ODBOIC Barring of all outgoing international calls
ODBOIEH Barring of all outgoing international calls except those directed to the home PLMN
country
ODBOIHZ Barring of all outgoing international calls except those directed to the home PLMN
country and barring of outgoing inter–zone calls
ODBOIZ Barring of outgoing inter–zone calls
ODBOPRE Barring of outgoing premium rate (entertainment) calls
ODBOPRI Barring of outgoing premium rate (information) calls
1AA 00014 0004 (9007) A4 – ALICE 04.10

ODBOZEH Barring of all outgoing inter–zone calls except those directed to the home PLMN
country
ODBSSM Barring of supplementary services management

ED 02

3BL 33096 CCAA ADAHA 36 / 60

60
ODBCT Barring of invocation of call transfer
• ODBCAT output parameter value

ODBCTC Barring of invocation of call transfer where at least one of the two calls is a call
not permitted without written authorization from Alcatel.

charged to the served subscriber


All rights reserved. Passing on and copying of this
document, use and communication of its contents

• ODBCAT output parameter value

ODBCTDC Barring of invocation of explicite call transfer doubly chargeable


• ODBCAT output parameter value

ODBCTI Barring of invocation of call transfer where at least one of the two calls is a call
charged to the served subscriber at international rate, namely the call charged
is either an ougoing international call or an incoming call when the served sub-
scriber roams outside the PLMN country
• ODBCAT output parameter value

ODBCTM Barring of multiple invocation of explicite call transfer


• ODBCAT output parameter value

ODBCTZ Barring of invocation of call transfer where at least one of the two calls is a call
charged to the served subscriber at inter–zone rate, namely the call is either an
outgoing inter–zone call or an incoming call when the served subcriber roams
in a VPLMN in a zone different from the HPLMN
• ODBCAT output parameter value

ODBOC Barring of all outgoing calls


• ODBCAT output parameter value

ODBOIC Barring of all outgoing international calls


• ODBCAT output parameter value

ODBOIEH Barring of all outgoing international calls except those directed to the home
PLMN country
• ODBCAT output parameter value

ODBOIHZ Barring of all outgoing international calls except those directed to the home
PLMN country and barring of outgoing inter–zone calls
• ODBCAT output parameter value

ODBOIZ Barring of outgoing inter–zone calls


• ODBCAT output parameter value

ODBOPRE Barring of outgoing premium rate (entertainment) calls


• ODBCAT output parameter value

ODBOPRI Barring of outgoing premium rate (information) calls


• ODBCAT output parameter value

ODBOZEH Barring of all outgoing inter–zone calls except those directed to the home PLMN
country
• ODBCAT output parameter value

ODBSSM Barring of supplementary services management



1AA 00014 0004 (9007) A4 – ALICE 04.10

ODBCAT output parameter value

OLDRES Old analysis result modified or deleted by means of an analysis or pre–analysis


command

ED 02

3BL 33096 CCAA ADAHA 37 / 60

60
• Symbolic output parameter name
• Parameter value: from 1 to 4000 or from 1 to 12000 according to an option

OOR Own oscillator’s controlled voltage of the CALX board is at upper or lower limit
not permitted without written authorization from Alcatel.

• TYPFAU output parameter value


All rights reserved. Passing on and copying of this
document, use and communication of its contents

OPAD Loss of own voltage controlled oscillator output (CALX)


• TYPFAU output parameter value

OPERNAME Operator name


• Symbolic output parameter name
• Parameter value: 16 alphanumeric characters

OPQSS Operational supplementary service activated


• Symbolic output parameter name
• Parameter value:
CBOC = Call Barring of all outgoing calls
CBOI = Call Barring of all international outgoing calls
CBOIEXHC = Call Barring of all outgoing international calls except those directed to the
home PLMN country
CFBUSY = Call forwarding on MS busy
CFNREPLY = Call forwarding on no reply
CFNREACH = Call forwarding on MS not reachable
CW = Call waiting
OS1 up to OS15 = Operator specific 1 to 15

OR Analised number is a MSISDN of an other PLMN


• Symbolic input and output parameter name
• Parameter value: Y (yes) or N (no), default value = N

ORD Ordinary, subscriber category


• CAT and CAX input and output parameters value

ORIG Call origin


• Symbolic input and output parameter name
• Parameter value:
CARCHK = Check of the carrier identification digits
CCBSRQ = Analysis of the called number for CCBS request
CLIEC = Calling Line Identification analysis for an emergency call
CLIOC = Calling Line Identification analysis for an outgoing call
CLITC = Calling Line Identification analysis or analysis of the number forwarding the
call or analysis of the call forwarding number for an incoming call or analysis of the call transfer
number for an incoming call
COLOC = Connected Line Identification analysis or analysis of the number forwarding
the call or analysis of the call forwarding number for an outgoing call or analysis of the call trans-
fer number for an outgoing call
COLTC = Connected Line Identification analysis for an incoming call
FTNINT = Forwarded–to–number for analysis interrogation
GMSCFW = Forwarded–to–number from a gateway MSC
IWSCADD = SC address (service center) received from MSC in SMS–IWMSC (Interwork-
ing of short messages service) for routing to an SC
MAPHONB = Handover number from a target MSC
1AA 00014 0004 (9007) A4 – ALICE 04.10

MAPMSRN = Translator call in the MSC gateway with a MSRN from HLR
MOBILE = Number asked by a mobile subscriber (outgoing call)
NETWORK = Number asked from RTC (incoming call received by the gateway)

ED 02

3BL 33096 CCAA ADAHA 38 / 60

60
NU = Deletion of the parameter value (in input only)
ORIGCD = First called number analysis
SCP = Called Party number from an SCP
SERVKEY = Analysis of the key for the SCP address retrieve service
not permitted without written authorization from Alcatel.

SSCODE = Operator Specific Supplementary Service code analysis


All rights reserved. Passing on and copying of this
document, use and communication of its contents

VERSHDL = Entity address analysis to determine the access key to the MAP versions data
VMSCFW = Forwarded–to number from a VLR
VSCADD = SC address (service center) received from mobile subscriber in MSC for for-
warding to SMS–IWMSC (Interworking of short messages service)

ORIGCD First called number analysis


• ORIG input and output parameter value

ORIGCDS Substitution of call forwarding mobile number for first called number
• Symbolic input and output parameter name
• Parameter value:
Y : Substitution
N : No substitution
NU: to delete the parameter value

OS1 up to OS15 Specific Operator


• ASUPS and SSUPS input and output parameters value
• OPQSS output parameter value

OUT SMIM or MIWX out of service


• STATE input and output parameter value
• Status field value of MIWXST parameter in output

OVERCS Override either all types of carrier selection or only the carrier selected at sub-
scription
• Symbolic input and output parameter name
• Parameter value:
Y : override all types of carrier selection
SUBSCR : override the carrier selected at subscription
N : no overriding (default value)

OVRIND Over–dialling code for a given dialling code


• Symbolic output parameter name
• Parameter value: from 1 to 30 digits (0 up to 9, A, B)
Take in account that A is used to code * and B to code #

PAD Short number for a dedicated PAD access


• NUMTYP input and output parameter value

PADPROF PAD profile number Stands for a set of predefined PAD parameters in the exter-
nal PAD equipment
• Symbolic input and output parameter name
• Parameter value: from 0 to 99 (default value = 0)
the values between 6 and 99 are reserved

PARNAME System parameter name


• Symbolic input and output parameter name

1AA 00014 0004 (9007) A4 – ALICE 04.10

Parameter value:
up to 16 alphanumeric characters and ”_”
ANN_CCBSRQ_NPCP = Announcement number for a MS which does not support PCP to indi-
cate that a CCBS request is possible

ED 02

3BL 33096 CCAA ADAHA 39 / 60

60
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 2047, value 0 for ”no announcement”)

ANN_CCBSRQ_PCP = Announcement number for a MS which supports PCP to indicate that


not permitted without written authorization from Alcatel.

a CCBS request is possible


All rights reserved. Passing on and copying of this
document, use and communication of its contents

(Value of type: DECVAL or HEXVAL)


(Value of DECVAL = 1 up to 2047, value 0 for ”no announcement”)

ANNOUNC_CW = Announcement number for call waiting


(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 2047, value 0 for ”no announcement”)

ANN_RECALL_CCBS = Announcement number for a MS which does not support CMSP to


indicate that it is a CCBS recall
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 2047, value 0 for ”no announcement”)

CA_TNRY = CAMEL timer (in secons, step 5) indicating the duration for the NoAn-
swer event required for arming EDP in the gsmSSF.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 5 up to 40, the value must be a multiple of 5,
default value=25)

CG_F_ITM_TIM= Delay before the first intermediate charging report generation,


expressed in seconds
(Value of type: DECVAL or HEXVAL)
(Minimum value of DECVAL = 180, default value=180)

CG_F_ITM_TIM_HB = Delay before the first intermediate charging report generation with
hot billing ticket, expressed in seconds
(Value of type: DECVAL or HEXVAL)
(Minimum value of DECVAL = 180, default value=180)

CG_P_ITM_TIM = Periodicity of intermediate charging report repetition, expressed in


seconds
(Value of type: DECVAL or HEXVAL)
(Minimum value of DECVAL = 300, default value=300)

CG_P_ITM_TIM_HB = Periodicity of intermediate charging report repetition with hot billing


ticket, expressed in seconds
(Value of type: DECVAL or HEXVAL)
(Minimum value of DECVAL = 300, default value=300)

CGAP_PERIOD = Period in seconds, during which OC calls controlled by the ”call ga


ping” function are counted.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 180, default value=10)

CGAP_OC_MAX = Maximum value of the counter of ”call gaping” OC calls per CPU.
(Value of type: DECVAL or HEXVAL)
1AA 00014 0004 (9007) A4 – ALICE 04.10

(Value of DECVAL = 1 up to 65535, default value=20)

CGAP_RED_RAT = Ratio to be applied to the ”call gaping” counter at the end of each
period CGAP_PERIOD. (C = C x CGAP_RED_RAT / 100).

ED 02

3BL 33096 CCAA ADAHA 40 / 60

60
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 99, default value=50)

DEFAULT_INAP = Default value used when the Service Key is not found in
not permitted without written authorization from Alcatel.

INAP_TAB_SK_XX
All rights reserved. Passing on and copying of this
document, use and communication of its contents

(Value of type: DECVAL or HEXVAL)


Numerical value: 1 or 2
1 = CAMEL (default)
2 = IN–SCF–V1

EC_ISDN_AD = Emergency call ISDN address


(Value of type: ADDNAT, ISDNNB)
EIR_N7_AD = EIR number 7 address
(Value of type: DPC, NID)

ENTI_RINIT_PER = Reinitialization period of the table describing, per application context,


for each entity of the PLMN, the version to use, expressed in days
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 255, default value=1)

ENTI_RINIT_TIM = Reinitialization time of the table describing, per application context,


for each entity of the PLMN, the version to use, expressed in hours
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 23, default value=23)

FAX_NT_TIMER = Timer defined in GSM REC 03.46 to process fax in non transparent
mode.
Used to initialize the SMIM.
This value depends on the transmission delay. It must be provided
in the case of satelite transmissions.
Unit : 10ms
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 255 (2550ms), 30 (300ms) default value

IC_R_VERS_XXXXXX = Highest version accepted in incoming transactions, inside the


HPLMN for application context XXXXXX.
The application context values named XXXXXX and the version val-
ues (VERSION) supported by the system are the following:
• AUFAIL = V3 (authentification failure report)
• CCOTRA = V3 (call control transfer)
• HANDOV = V1, V2, and V3 (handover control)
• HLRRST = V1 and V2 (restart of HLR, reset HLR)
• LOCCAN = V1, V2 and V3 (location cancellation)
• NWUSSH = V2 (supplementary services transparent processing)
• REPORT = V3 (reporting)
• RNBENQ = V1, V2 and V3 (roaming number request)
• SINENQ = V3 (subscriber data request)
• SMALRT = V1 and V2 (short messages SC alerting)
• SMMORL = V1, V2 and V3 (outgoing short message)
• SMTCRL = V2 and V3 (incoming short message)

1AA 00014 0004 (9007) A4 – ALICE 04.10

SUBDTM = V1, V2 and V3 (subscriber data update)


• TRCING = V2 and V3 (call tracing)
• VLRRET = V2 (inter VLR information retrieval)
(Value of type: VERSION)

ED 02

3BL 33096 CCAA ADAHA 41 / 60

60
(Value of VERSION = V1, V2, V3 or NSUP ”not supported version”)

INAP_TAB_AC_XX Table of the INAP protocols to be used between the RCF and an
intra–PLMN SCF
not permitted without written authorization from Alcatel.

A protocol XX is associated to the Service Key with the same


All rights reserved. Passing on and copying of this
document, use and communication of its contents

index XX (INAP_TAB_SK_XX)
(Value of type: DECVAL or HEXVAL)
Numerical value: 1 or 2
1 = CAMEL (default)
2 = IN–SCF–V1

INAP_TAB_SK_XX ServiceKey table.


For every INAP_TAB_SK_XX parameter is associated with the same
index a protocol to be used between the RCF and an intra–PLMN
SCF (see INAP_TAB_AC_XX)
(Value of type: DECVAL or HEXVAL)
(Minimum value of HEXVAL = 0, default value = 0)
(Maximum value of HEXVAL = H’7FFFFFFF))

LGC_SUP_TIM = Long call supervision timer, expressed in quarters of hour


(Value of type: DECVAL or HEXVAL)
(Minimum value of DECVAL = 0 ”no supervision”)
(Maximum value of DECVAL = 72 ”18 hours”, default value=72)

LGC_SUP_TIM_HB = Long call supervision timer for calls with hot billing, expressed in
quarters of hour
(Value of type: DECVAL or HEXVAL)
(Minimum value of DECVAL = 0 ”no supervision”)
(Maximum value of DECVAL = 72 ”18 hours”, default value=72)

LGS_ANN_TIM = Long setup announcement timer. Announcement to the calling party


is sent at the timer expiry.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 5 up to 30, default value : 15)
LGS_ANN_TIM is allowed when ”Long setup announcement” option
is active.

LOCNB_DEF Default value of Localisation identity used when LOCNB parameter


is not provided in MMC CREREV.
(Value of type: ADDNAT, ISDNNB)
(Default value: MSC address)
• LOCNB_DEF is considered as being entered in the national or international format
depending on the PLMN parameter ”nature of address chosen for LOCNB”

MSC_ISDN_AD = Local MSC ISDN address


(Value of type: ADDNAT, ISDNNB)

NB_MAX_CONNECT= Number max of receipt of CONNECT operation received from a SCF


for that given SCF dialogue.
(Value of type: DECVAL or HEXVAL)
1AA 00014 0004 (9007) A4 – ALICE 04.10

(Value of DECVAL = 1 up to 20, default value : 10)

NB_PAG_ATTEMPT = Number of paging message attempts.


(Value of type: DECVAL or HEXVAL)

ED 02

3BL 33096 CCAA ADAHA 42 / 60

60
(Value of DECVAL = 1 or 2, default value=2)
NB_PAG_ATTEMPT is allowed when ”HPA after n paging attempts”
option is active.
not permitted without written authorization from Alcatel.

NB_PAG_REP Number of paging message repetitions


All rights reserved. Passing on and copying of this
document, use and communication of its contents

(Value of type: DECVAL or HEXVAL)


(Value of DECVAL = 0 to 2, default value = 1)

NPDB_ADD_MNP Number Portability Date Base ISDN address used as SCCP called
party address to query the NPDB when the Mobile Number Portabil-
ity is based on IN.
(Value of type: ADDNAT, ISDNNB)

NB_PAG_GS_ATT Number of paging message repetitions on Gs interface.


(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 to 2, default value = 1)

NOREPLY_TIM = Default value for the no reply condition timer, expressed in seconds
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 5 up to 30, default value=20)
(the value must be a multiple of 5)

NUM_PLAN_PHASE = Current numbering plan phase for translation


(Value of type: DECVAL or HEXVAL)

N2_RLP= RLP number of retransmission attempts N2.


Used to initialize the SMIM. This value is used by the IWF to negotiate
the N2 number with the MS.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 255, default value : 6)

OG_R_VERS_YYYYYY=Highest version used in outgoing transactions, within the HPLMN, for


application context YYYYYY .
The application context values named YYYYYY and the version val-
ues (VERSION) supported by the system are the following:
• CCOMP = V3 (call completion)
• CCOTRA = V3 (call control transfer)
• EQMNGT = V1 and V2 (equipment management MSC–EIR)
• HANDOV = V1, V2 and V3 (handover control)
• INFRET = V1 and V2 (information retrieval)
• LOCUPD = V1, V2 and V3 (location update)
• LOCRET = V1, V2 and V3 (location information retrieval)
• MSPURG = V2 and V3 (mobile station purge)
• NWFSSH = V1 and V2 (supplementary services functional processing)
• NWUSSH = V2 (network unstructured supplementary services processing)
• REPORT = V3 (reporting)
• SMGWAY = V1, V2 and V3 (short message gateway)
• SMMORL = V1, V2 and V3 (outgoing short message)
• SMTCRL = V2 and V3 (incoming short message)

1AA 00014 0004 (9007) A4 – ALICE 04.10

SMWDTM = V1 and V2 (short messages waiting data management)


• SSNOTI = V3 (supplementary services notification requested)
• AUFAIL = V3 (authentication failure report)
• VLRRET = V2 (inter VLR information retrieval)

ED 02

3BL 33096 CCAA ADAHA 43 / 60

60
(Value of type: VERSION)
(Value of VERSION = V1, V2, V3 or NSUP ”not supported version”)

PLMN_CARRIER= Default PLMN carrier.


not permitted without written authorization from Alcatel.

The first digit indicates the network identification type (ITU=0,


All rights reserved. Passing on and copying of this
document, use and communication of its contents

national=2), the second and third digits the network identification


plan (00 to 15), the four following digits the carrier identification code
(completed with a sequence of 0 in front it less than 4 digits).
(Value of type: DIGITS)
(Value of DIGITS = 7 digits)

SC_AUTH_1N = Threshold for authentication 1/n. Authentication is performed when


the threshold is reached.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 256, default value : 10)
SC_AUTH_1NAuthentication 1/n” option is active.

SM_PREF_PATH = The prefered delivery path for short message in the SMS–GMSC.
(Value of type: BOOLVAL)
(Value of BOOLVAL )
(TRUE= means ”via VMSC” )
(FALSE= means ”via SGSN”, default value )

TFSAT_T1 Timer to be used for transparent fax with satellite transmissions.


Supervision timer to avoid collision.
Provided to the SMIM at initialisation time.
(Value of type: DECVAL or HEXVAL )
(unit: 10ms)
(Value of DECVAL = from 0 up to 255 ( 2550ms), 90 ( 900ms) default
value)

TFSAT_T2 Timer to be used for transparent fax with satellite transmissions.


Additional supervision timer to avoid collision.
Provided to the SMIM at initialisation time.
(Value of type: DECVAL or HEXVAL )
(unit: 10ms)
(Value of DECVAL = from 0 up to 255 ( 2550ms), 20 ( 200ms) default
value)

TFSAT_T3 Timer to be used for transparent fax with satellite transmissions.


Delay before sending a buffered response.
Provided to the SMIM at initialisation time.
(Value of type: DECVAL or HEXVAL )
(unit: 100ms)
(Value of DECVAL = from 0 up to 255 ( 25500ms), 45 ( 4500ms)
default value)
1AA 00014 0004 (9007) A4 – ALICE 04.10

ED 02

3BL 33096 CCAA ADAHA 44 / 60

60
TFSAT_T4 Timer to be used for transparent fax with satellite transmissions.
Timer to avoid retransmission of a command if a response has been
received.
Provided to the SMIM at initialisation time.
not permitted without written authorization from Alcatel.

(Value of type: DECVAL or HEXVAL )


All rights reserved. Passing on and copying of this
document, use and communication of its contents

(unit: 100ms)
(Value of DECVAL = from 0 up to 255 ( 25500ms), 25 ( 2500ms)
default value)

TFSAT_T5 Timer to be used for transparent fax with satellite transmissions.


Delay before starting to send white scan lines.
Provided to the SMIM at initialisation time.
(Value of type: DECVAL or HEXVAL )
(unit: 100ms)
(Value of DECVAL = from 0 up to 255 ( 25500ms), 20 ( 2000ms)
default value)

TFSAT_T6 Timer to be used for transparent fax with satellite transmissions.


Duration of HDLC flags emission.
Provided to the SMIM at initialisation time.
(Value of type: DECVAL or HEXVAL )
(unit: 10ms)
(Value of DECVAL = from 0 up to 255 ( 2550ms), 50 ( 500ms) default
value)

TFSAT_T7 Timer to be used for transparent fax with satellite transmissions.


Duration for Bit Error Rate (BER) estimation.
Provided to the SMIM at initialisation time.
(Value of type: DECVAL or HEXVAL )
(unit: 10ms)
(Value of DECVAL = from 0 up to 165 ( 1650ms), 130 ( 1300ms)
default value)

TFSAT_T8 Timer to be used for transparent fax with satellite transmissions.


Delay after training to start BER estimation.
Provided to the SMIM at initialisation time.
(Value of type: DECVAL or HEXVAL )
(unit: 10ms)
(Value of DECVAL = from 0 up to 165 ( 1650ms), 10 ( 100ms) default
value)

TFSAT_T9 Timer to be used for transparent fax with satellite transmissions.


Duration between page data and post message commands.
Provided to the SMIM at initialisation time.
(Value of type: DECVAL or HEXVAL )
(unit: 10ms)
(Value of DECVAL = from 0 up to 255 ( 2550ms), 8 ( 80ms) default
value)

THPA = MSC high penetration alerting timer, expressed in seconds


1AA 00014 0004 (9007) A4 – ALICE 04.10

(Value of type: DECVAL or HEXVAL)


(Value of DECVAL = 0 up to 180)
(the value must be a multiple of 4)
(default value for ACeS=0)

ED 02

3BL 33096 CCAA ADAHA 45 / 60

60
(default value for SATCOM=120)
THPA is allowed when ”High Penetration Alerting” option is active.

TIME_ZONE_CODE = Code of the time zone the RCF resides in.


not permitted without written authorization from Alcatel.

(Value of type: DECVAL or HEXVAL)


All rights reserved. Passing on and copying of this
document, use and communication of its contents

(Value of DECVAL = 1 up to 255)

TONE_CCBSRQ_NPCP= Tone number for a MS which does not support PCP to indicate that
a CCBS request is possible
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 127)

TONE_CCBSRQ_PCP = Tone number for a MS which supports PCP to indicate that a CCBS
request is possible
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 127)

TONE_CW = Tone number for call waiting


(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 127, default value : value of ringback-
tone)

TONE_INSERT_TIME = CAMEL timer (in seconds, step 5). When set to ”x” value, it indicates
that the RCF must insert a tone ”x” seconds before the end of the call.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 5 up to 60, default value : 30, the value must be
a multiple of 5)

TONE_RECALL_CCBS= Tone number for a MS which does not support CMSP to indicate that
it is a CCBS recall
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 127)

TOTC = Synchronisation timer between subscribes data restoration and pag-


ing for an optimized terminating call, expressed in seconds
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 10, default value=2)
TOTC is allowed when ”Optimized TC” option is active.

TPAG = MSC normal paging timer, expressed in seconds


(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 10, default value=4)
TPAG is allowed when ”High Penetration Alerting” option is active.

TSAT = Channel mode modify timer, expressed in milliseconds


(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 2000, default value=0)
(the value must be a multiple of 100)

TT_SRF_MNP Translation Type value set in the SCCP called party address of call
1AA 00014 0004 (9007) A4 – ALICE 04.10

related messages when the Mobile Number Portability is based on


Signalling Relay Function (MNP/SRF)
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 to 255, default value = 0)

ED 02

3BL 33096 CCAA ADAHA 46 / 60

60
TY_NUM_INTCS = Type of number for international calls with carrier indication. This
value is sent on INAP interface when the translation result
(MODTRR) indicates : NUMTYP=INTCS.
not permitted without written authorization from Alcatel.

(Value of type: DECVAL or HEXVAL)


All rights reserved. Passing on and copying of this
document, use and communication of its contents

(Value of DECVAL = 0 up to 127, default value : 117)

TY_NUM_INTRA = Type of number for intra–PLMN calls (SOR) without carrier indica-
tion. This value is sent on INAP interface when the translation result
(MODTRR) indicates : NUMTYP=INTRA.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 127, default value : 125)

TY_NUM_INTRACS = Type of number for intra–PLMN calls (SOR) with carrier indication.
This value is sent on INAP interface when the translation result
(MODTRR) indicates : NUMTYP=INTRACS.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 127, default value : 124)

TY_NUM_NATCS = Type of number for national calls with carrier indication. This value
is sent on INAP interface when the translation result (MODTRR) indi-
cates : NUMTYP=NATCS.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 127, default value : 116)

TY_NUM_RES1 to RES4 = Types of numbers in reserve for national use. These values are
sent on INAP interface when the translation result (MODTRR) indi-
cates : NUMTYP=RES1 to RES4.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 127)
(Default values : RES1=112, RES2=113, RES3=114, RES4=115)

T1_CCBS = Time, in seconds, during which a subscriber may ask for a ccbs
request when his call has failed due to busy called subscriber.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 15 up to 120, default value=30)

T1_FR12_RLP = RLP T1 acknowledgement timer for full rate channels at 12kbps.


Used to initialize the SMIM. This value is used by the IWF to negotiate
the T1 timer value with the MS.
T1 must follow the rule: T1>T2+2xTD.
T2 is the reply delay, equal to 20ms.
TD is the transmission delay between the MS and the IWF.
(Value of type: DECVAL or HEXVAL)
(unit: 10ms.)
(Value of DECVAL = from 0 up to 255 (2550ms), 48 (480ms) default
value)

T1_FR145_RLP = RLP T1 acknowledgement timer for full rate channels at 14.5kbps.


Used to initialize the SMIM. This value is used by the IWF to negotiate
1AA 00014 0004 (9007) A4 – ALICE 04.10

the T1 timer value with the MS.


T1 must follow the rule: T1>T2+2xTD.
T2 is the reply delay, equal to 20ms.
TD is the transmission delay between the MS and the IWF.

ED 02

3BL 33096 CCAA ADAHA 47 / 60

60
(Value of type: DECVAL or HEXVAL)
(unit: 10ms.)
(Value of DECVAL = from 0 up to 255 (2550ms), 52 (520ms) default
value)
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents

T1_HR6_RLP = RLP T1 acknowledgement timer for half rate channels at 6kbps.


Used to initialize the SMIM. This value is used by the IWF to negotiate
the T1 timer value with the MS.
T1 must follow the rule: T1>T2+2xTD.
T2 is the reply delay, equal to 20ms.
TD is the transmission delay between the MS and the IWF.
(Value of type: DECVAL or HEXVAL)
(unit: 10ms.)
(Value of DECVAL = from 0 up to 255 (2550ms), 78 (780ms) default
value)

T4_CCBS = Time, in seconds, during which a subscriber who is idle and who has
asked for a CCBS request may accept the recall.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 20 up to 30, default value=25)

T5 MSC paging on Gs Interface timer, expressed in seconds


(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 2 up to 20, default value = 4)

T5_BSC = Timer to ignore BSC overload message, expressed in seconds


(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 100, default value=2)
T5_BSC is allowed when ”Handling of paging congestion” option is
active.

T5_LAC = Timer to ignore (BSC, LAC) overload message, expressed in


seconds
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 100, default value=2)
T5_LAC is allowed when ”Handling of paging congestion” option is
active.

T6_BSC = Timer to determine the end of BSC overload, expressed in seconds


(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 100, default value=5)
T6_BSC is allowed when ”Handling of paging congestion” option is
active.

T6_LAC = Timer to determine the end of (BSC, LAC) overload, expressed in


seconds
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 100, default value=5)
T6_LAC is allowed when ”Handling of paging congestion” option is
active.
1AA 00014 0004 (9007) A4 – ALICE 04.10

T10_CCBS= Time, in seconds, during which a subscriber who is busy and who has
asked for a CCBS request may accept the recall.
(Value of type: DECVAL or HEXVAL)

ED 02

3BL 33096 CCAA ADAHA 48 / 60

60
(Value of DECVAL = 20 up to 30, default value=25)

VLR_ISDN_NB = Local VLR ISDN number


(Value of type: ADDNAT, ISDNNB)
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents

W_IWF_MS_RLP2 = RLP version 2 window size from IWF to MS. Used to initialize the
SMIM. This value is used by the IWF to negotiate the window size
from IWF to MS.
The value must be a multiple of 8.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 480, default value: 240)

W_MS_IWF_RLP2 = RLP version 2 window size from MS to IWF. Used to initialize the
SMIM. This value is used by the IWF to negotiate the window size
from MS to IWF.
The value must be a multiple of 8.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 480, default value: 240)

PERIOD Observation counters collection period


• Symbolic input and output parameter name
• Parameter value:
from 5 to 65535 for the FAST class (fast collection)
from 30 to 65535 for the SLOW class (slow collection)

PHASEn Phase 1 up to n. Predefined BSCTYP values


• BSCTYP input parameter value

PHASE Numbering plan phase


• Symbolic input and output parameter name
• Parameter value: 1 up to 10
• Value 0 : Deletion of the parameter value (for MODTRR)
default value = current phase (for MODPRE and DELPRE)

PLMN Originating PLMN, translation


• Symbolic input and output parameter name
• Parameter value:
HPLMN = Home PLMN
VPLMN = Visitor PLMN
NU = Deletion of the parameter value (in input only)

PLMN PLMN Identifier


• Symbolic input and output parameter name
• Parameter value: 5 or 6 digits, MCC followed by MNC
MCC = Mobile Country Code: 3 digits
MNC = Mobile Network Code: 2 or 3 digits

PLMNAD Network address (beginning of E164 address)


• Symbolic input and output parameter name
• Parameter value: from 1 to 15 digits

PLMNNAME PLMN name (1)


1AA 00014 0004 (9007) A4 – ALICE 04.10

• Symbolic input and output parameter name


• Parameter value : up to 8 alphanumeric characters
PLMN = default value

ED 02

3BL 33096 CCAA ADAHA 49 / 60

60
Up to 32 values can be defined, including default value ’PLMN’
Note (1) Only if ’Mobile Number Portability’ function is offered.

PMP Presentation Mode Permanent of calling subscriber identity


not permitted without written authorization from Alcatel.

• CLIOP output parameter value


All rights reserved. Passing on and copying of this
document, use and communication of its contents

PMTPA Presentation Mode Temporary of calling subscriber identity by call allowed


• CLIOP output parameter value

PMTPR Presentation Mode Temporary of calling subscriber identity by call restricted


• CLIOP output parameter value

PRE Charged call with entertainment type (Premium Rate)


• PRMRATE input and output parameter value

PRI Charged call with information type (Premium Rate)


• PRMRATE input and output parameter value

PRIV Private numbering plan


• NUMPL input and output parameter value

PRMRATE Premium Rate (Call with special tariff type to kiosk or server)
• Symbolic input and output parameter name
• Parameter value:
PRE : Charged call of entertainment type
PRI : Charged call of information type
NO : The number analysis does not match one of these types
NU : to delete the parameter value

PTT Failure of PTT fast test


• OBCERR output parameter value

RADD Rank of the first digit to be added


• Symbolic input and output parameter name
• Parameter value: absolute rank from 1 to 80
• Default value 1 if ADD provided

RADIUS Radius of the cell (or a set of cells), (in GSM environment), or of a service area
(in UMTS environment).
• Symbolic input and output parameter name
• Parameter value: between 0 and 1800000 (expressed in meters)
• The value 0 is only allowed in MODREV command to delete the LATIT, LONGIT and RADIUS
values.

RAM Failure of RAM fast test


• OBCERR output parameter value

RANA Rank of the following digit to be analysed


• Symbolic input and output parameter name
• Parameter value: absolute rank from 1 to 80
value 0 to delete the parameter value
Default value : rank + 1 of the last analysed digit
The default value is usually not convenient when the already translated digits have been modi-
1AA 00014 0004 (9007) A4 – ALICE 04.10

fied. The RANA value must be given depending on the remaining digits to be translated after
modification.

RAPCTX Reception application context

ED 02

3BL 33096 CCAA ADAHA 50 / 60

60
• Symbolic input and output parameter name
• Value of parameter:
Application contexts supported by the system:
AUFAIL = Authentication Failure Report
not permitted without written authorization from Alcatel.

HLRRST = HLR reset (location register restart)


All rights reserved. Passing on and copying of this
document, use and communication of its contents

LOCCAN = location cancellation


NWUSSH = network unstructured supplementary services handling
RNBENQ = roaming number request
SMALRT = short messages SC alerting
SMMORL = mobile originating short message relay
SMTCRL = mobile terminating short message relay
SUBDTM = subscriber data update
VLRRET = inter VLR information retrieval
SINENQ = Subscriber data enquiry
CCOTRA = call control transfer
HANDOV = handover control
REPORT = reporting
Minimum and maximum version values supported by the system for each application context:
AUFAIL = V3
HLRRST = V1 and V2
LOCCAN = V1, V2 and V3
NWUSSH = V2
RNBENQ = V1, V2 and V3
SMALRT = V1 and V2
SMMORL = V1, V2 and V3
SMTCRL = V2 and V3
SUBDTM = V1, V2 and V3
VLRRET = V2
SINENQ = V3
CCOTRA = V3
HANDOV = V1, V2, and V3
REPORT = V3

RDEL Rank of the first digit to be deleted


• Symbolic input and output parameter name
• Parameter value: absolute rank from 1 to 80
RDEL+DEL must be less than 81
• Default value 1 if DEL provided

RECREADD Recreation of address (type of result)


• TYPE input and output parameter value

REL Release the call


• DefCallHDL field value of the OCSM parameter in output

REPORT Reporting
• APCTX and RAPCTX input and output parameter value

RESTART Restart failure during SMIM test


• OBCFAU output parameter value

RESULT Analysis result identified by a number


1AA 00014 0004 (9007) A4 – ALICE 04.10

• Symbolic input and output parameter name


• Parameter value: from 1 to 4000 or from 1 to 12000 according to an option

ED 02

3BL 33096 CCAA ADAHA 51 / 60

60
RES1 to RES4 Reserved values 1 to 4 for national use
• NUMTYP input and output parameter value

RIMSI Rank of the digit where all or part of IMSI must be inserted
not permitted without written authorization from Alcatel.

• Symbolic input and output parameter name


All rights reserved. Passing on and copying of this
document, use and communication of its contents

• Parameter value: absolute rank from 1 to 80 (Default value 1 if INIMSI parameter provided)

RINS Rank of the digit where all or part of the additional number must be inserted
• Symbolic input and output parameter name
• Parameter value: absolute rank from 1 to 80
• Default value 1 if INS provided.

RJA The PCM link is seen faulty by the remote entity (SSP) (loss of frame alignment)
• TYPFAU output parameter value

RLAC Rank of the digit where all or part of the location (LAC+CI in GSM, or LAC + SAC
in UMTS ) shall be inserted
• Symbolic input and output parameter name
• Parameter value: absolute rank between 1 and 80
• Default value 1 if INSLAC is provided

RNBENQ Roaming number request


• RAPCTX input and output parameter value

RNCDPC Radio Network Controller administration SS7 Distant Point Code


• Symbolic input and output parameter value
• Parameter value: value between 0 and 16383 or between 0 and 16777215 according to the
address length used in the network

RNCNAM Radio Network Controller administration Name


• Symbolic input and output parameter value
• Parameter value: up to 8 alphanumeric characters
• Note: RNCNAM and BSCNAM can not have common values

RNCNUM Radio Network Controller administration Number


• Symbolic input and output parameter value
• Parameter value: 2 digits between 00 and 95

RNCID Radio Network Controller administration UTRAN Identifier


• Symbolic input and output parameter value
• Parameter value: value between 0 and 4095

RNCDN Network routing number concatenated with called directory number


• NUMTYP input and output parameter value

RNNAT Network routing number in national number format


• NUMTYP input and output parameter value

RNSPE Network routing number in network–specific number format


• NUMTYP input and output parameter value

ROAMTYP Roaming type for the mobile


• Symbolic input and output parameter name
1AA 00014 0004 (9007) A4 – ALICE 04.10

• Parameter value:
– ALL : the same pool for INTER (foreign mobile) and INTRA (national mobile)
– INTER : pool for foreign mobiles
– INTRA : pool for national mobiles

ED 02

3BL 33096 CCAA ADAHA 52 / 60

60
The ALL value is available or not depending on the PLMN.

ROUTING Call routing (type of result)


• TYPE input and output parameter value
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents

RPAD Loss of the clock provided by the associated CALX board (VCO) voltage con-
trolled oscillator output
• TYPFAU output parameter value

RRDTUF Roaming restriction due to not supported function


• Symbolic output parameter name
• Parameter value: Y or N

RVERSION Maximum version of application context to be used in incoming dialogues


• Symbolic input and output parameter name
• Parameter value:
V1 : version 1
V2 : version 2
V3 : version 3
NSUP : application context not existing in V1 and not accepted for the foreign network
Default value at creation: value depending on HPLMN
Consult the RAPCTX parameter in order to know the minimum and maximum versions sup-
ported by the system for each application context.

SAC Service Area Code


• Symbolic input and output parameter name
• Parameter value: value between 0 and 65535
• Note: A service area is uniquely identified by MCC+MNC+LAC+SAC

SAMEKEY Indication of the analysed number used as key to determine the MAP version
• Symbolic input and output parameter name
• Parameter value:
Y : The analysed number is the key for determining the MAP version; in this case the MAPKEY
parameter must be not provided.
N : The analysed number is not the key for determining the MAP version (default value) in this
case the MAPKEY parameter must be provided.

SBSTAT Subscriber state


• Symbolic output parameter name
• Parameter values:
ATTACH The subscriber uses a mobile station
DETACH The subscriber doesn’t use a mobile station

SCADD SC address received from the mobile subscriber in VMSC


• ORIG input and output parameter value

SCP Requested number from SCP


• ORIG input and output parameter value

SERVKEY Analyse of the key of the service eabling the SCP address retrieval
• ORIG input and output parameter value

SGSGA Global address of the adjacent SGSN


1AA 00014 0004 (9007) A4 – ALICE 04.10

• Symbolic input and output parameter name


• Parameter value: up to 15 digits from 1 to 999999999999999

ED 02

3BL 33096 CCAA ADAHA 53 / 60

60
SINENQ Subscriber data enquiry
• RAPCTX input and output parameter value

SK Key service
not permitted without written authorization from Alcatel.

• Symbolic input and output parameter name


All rights reserved. Passing on and copying of this
document, use and communication of its contents

• Parameter value: 4 hexadecimal characters


0 value to delete the parameter value

SLIP Slip of the clock signal


• TYPFAU output parameter value

SLOW Slow counters collection


• CLASS input and output parameter value

SMALRT Short message alert


• RAPCTX input and output parameter value

SMMORL Short message outgoing


• Input and output APCTX and RAPCTX parameters value

SMSMO Short messages services for sending


• BS input and TS output parameters values

SMTCRL Mobile terminating short message relay


• APCTX and RAPCTX input and output parameter value

SMWDTM Short message waiting data management


• APCTX input and output parameter value

SN Subscriber Number
• NUMTYP input and output parameter value

SORT Edition sort type


• Symbolic input parameter name
• Parameter value:
IMSI = sort by IMSI
ISDN = sort by MSISDN
HLRNB= sort by HLRNB

SPEECH Speech transmission (basic service group, TS10)


• BS input and TS and OBSCRI output parameter value

SPEECH Speech calls


• IWFTYP input and output parameter value

SPS Special service


• NUMTYP input and output parameter value

SSCODE Supplementary service code analysis


• ORIG input and output parameter value

SSCSI Supplementary Service notification CAMEL Subscription Information


• Symbolic output parameter name
• Parameter value:
1AA 00014 0004 (9007) A4 – ALICE 04.10

ECT = Explicit call transfer


MPTY = Multi party
CD = Call deflection

ED 02

3BL 33096 CCAA ADAHA 54 / 60

60
SSNOTI Supplementary services notification requested
• APCTX input and output parameter value

SSSCPADD SCP address


not permitted without written authorization from Alcatel.

• Symbolic output parameter name


All rights reserved. Passing on and copying of this
document, use and communication of its contents

• Parameter value: NP followed by 15 digits maximum, NP= 91 (international)

SSUPS Subscribed supplementary service


• Symbolic input and output parameter name
• Parameter value:
CBOC = Call Barring of all outgoing calls
CBOI = Call Barring of all international outgoing calls
CBOIEXHC = Call Barring of all outgoing international calls except those directed to the HPLMN
country
CFBUSY = Call forwarding on MS busy
CFNREPLY = Call forwarding on no reply
CFNREACH = Call forwarding on MS not reachable
AOCC = Advice of charge charging
AOCI = Advice of charge information
CCBSA = Call Completion on Busy Subscriber, A side
CCBSB = Call Completion on Busy Subscriber, B side
CH = Call hold
CW = Call waiting
CLIP = Calling Line Identification Presentation
CLIR = Calling Line Identification Restriction
COLP = Connected Line Identification Presentation
COLR = Connected Line Identification Restriction
ECT = Explicit call transfer service
MPTY = Multiparty
MCI = Malicious Call Identification
OS1 up to OS15 = Operator specific 1 to 15

STATE Requested state of SMIM


• Symbolic input parameter name
• Parameter value:
IN = SMIM in service
OUT = SMIM out of service

STATE State of SMIM


• Symbolic output parameter name
• Parameter value:
IN = SMIM is in service
INIS = SMIM is in service but isolated
INIT = initialization of SMIM is running
OUT = SMIM is out of service

STCOLP Authorization / prohibition of the supplementary service COLP for customer in


roaming (accepted PLMN administration)
• Symbolic input and output parameter name
• Parameter value:
Y = Supplementary service COLP allowed for customer in roaming (default value at creation
1AA 00014 0004 (9007) A4 – ALICE 04.10

time)
N = Supplementary service COLP forbidden for customer in roaming.

ED 02

3BL 33096 CCAA ADAHA 55 / 60

60
STCOLR Authorization / prohibition of the supplementary service COLR for customer in
roaming (accepted PLMN administration)
• Symbolic input and output parameter name
• Parameter value:
not permitted without written authorization from Alcatel.

Y = Supplementary service COLR allowed for customer in roaming (default value at creation
All rights reserved. Passing on and copying of this
document, use and communication of its contents

time)
N = Supplementary service COLR forbidden for customer in roaming.

STMPTY Authorization / prohibition of the supplementary service MPTY for customer in


roaming (accepted PLMN administration)
• Symbolic input and output parameter name
• Parameter value:
Y = Supplementary service MPTY allowed for customer in roaming (default value at creation
time)
N = Supplementary service MPTY forbidden for customer in roaming.

STT Failure of STT fast test


• OBCERR output parameter value

SUBADR Subaddress
• Symbolic output parameter name
• Parameter value: from 4 to 42 hexadecimal characters

SUBDTM Subscriber data update


• RAPCTX input and output parameter value

SUBPROF Subscriber profile


• Symbolic input and output parameter name
• Parameter value: 0 up to 99
NU = Deletion of the parameter value (in input only)

TARGET Target translator number in order to loop again in another translator


• Symbolic input and output parameter name
• Parameter value: between 1 and 64
0 to delete the parameter value

TEL Telephony service, basic service


• BS input and output and TS and OBSCRI output parameters value

THPA MSC high penetration alerting delay


• Symbolic input and output parameter name
• Parameter value: 0 up to 120 seconds by 4 seconds steps

TCM2 ”Class Mark 2” IE truncated to 4 octets in ”Handover Request” message


(Default value)
• BSCTYP output parameter value

TIMEOUT Timer expiry during SMIM test


• OBCFAU output parameter value

TMSI Temporary Mobile Subscriber Identity


• Symbolic input and output parameter name
• Parameter value: 8 hexadecimal digits (=32 bits)
1AA 00014 0004 (9007) A4 – ALICE 04.10

TMSIAGE Temporary Mobile Subscriber Identity Age


• Symbolic output parameter name

ED 02

3BL 33096 CCAA ADAHA 56 / 60

60
• Parameter value: TMSI age in format: number of days, hours, minutes and seconds

TPAG Timer for the MSC normal ”paging”


• Symbolic input and output parameter name
not permitted without written authorization from Alcatel.

• Parameter value: 1 up to 10 seconds


All rights reserved. Passing on and copying of this
document, use and communication of its contents

TRACT Subscribers with active trace


• Symbolic input and output parameter name
• Parameter value:
In input : Y (yes)
In output : Y (yes) or N (no)

TRAD Translator number


• Symbolic input and output parameter name
• Parameter value: between 1 and 64

TRANS Transaction number


• Symbolic input and output parameter name
• Parameter value: 5 digits integer in decimal numbering

TRSGRP Transgroup numbering type


• NUMTYP input and output parameter value

TS Tele service type, basic service


• Symbolic output parameter name
• Parameter value:
SPEECH= Speech (TS10 basic service group)
TEL = Telephony (TS11 basic service)
EC = Emergency Call (TS12 basic service)
SMSMO= Short message originating service
TS60 = Facsimile service (basic service group)
FAX61= Facsimile service (TS61)
FAX62= Facsimile service (TS62)

TSAT Timer for channel mode modification


• Symbolic input and output parameter name
• Parameter value: 0 up to 2000 milliseconds by 100 milliseconds steps

TS60 Facsimile service (basic service group)


• BS input and TS and OBSCRI output parameters value

TYPE Analysis result type


• Symbolic input and output parameter name
• Parameter value:
HLRROUT = Result type ”interrogation of HLR”
LENGTH = Result type ”result depending on length”
LOOPANA = Result type ”loop again in another translator”
LOOPPREA = Result type ”loop again in preanalysis”
MAPVERS = Result type ”Key for MAP version”
RECREAD = Result type ”recreation of address”
ROUTING = Result type ”call routing”
ACCESS = Result type ”result according to type of access”
1AA 00014 0004 (9007) A4 – ALICE 04.10

TYPFAU List of faults of DTRX and CALX boards (1 to 10 values).


• Symbolic output parameter name
• Parameter value:

ED 02

3BL 33096 CCAA ADAHA 57 / 60

60
For DTRX
AIS : Reception of continuous ”1” on the PCM link.
CRC41: The number of multiframes received with a wrong CRC4 indicates an error bit rate
greater than 10–3 (analysis during 1 s).
not permitted without written authorization from Alcatel.

CRC42: The number of multiframes with a wrong CRC4 indicates an error bit rate greater than
All rights reserved. Passing on and copying of this
document, use and communication of its contents

10–6 (analysis during 1 minute).


ERR1: The error bit rate has reached 10–3 (count during 1 second the errors in the frame align-
ment signal).
ERR2: The error bit rate has reached 10–5 (count during 1 minute the errors in the frame align-
ment signal).
EXT : Problem is external to the reception trunk of the DTRX board.
HDB3: Excessive error rate in the HDB3 coding received.
LFA : Loss of frame alignment on the PCM link.
LIS : Loss of incoming signal detected by the DTRX board.
LKF : The signalling link (TS16) is out of service.
INT : Problem detected in the reception trunk of the DTRX board.
MAC : The CALX board did not acknowledge the DTRX alarm report (the reinitialization of the
CALX board is probably in progress).
MSR : The DTRX board does not send any more alarm report to the CALX board (DTRX board
is probably in a phase of reinitialization).
RJA : The PCM link is seen faulty by the remote entity (SSP) (loss of frame alignment).
SLIP: Slip of the clock signal.
For CALX
IPAD: Loss of clock reference signal from DTRX board.
MMC : Problem on the MMC interface of the CALX board.
OOR : Own oscillator’s controlled voltage of the CALX board is at upper or lower limit.
OPAD: Loss of own voltage controlled oscillator output (CALX).
RPAD: Loss of other CALX voltage controlled oscillator output.
UNL : Synchronization failure between the clocks of the DTRX and CALX boards.

TYPTST Type of SMIM test


• Symbolic output parameter value
• Parameter value:
DIGITAL = digital
ANALOG = analog

T5BSC Timer during which the BSC congestion messages are ignored
• Symbolic input and output parameter name
• Parameter value: 1 up to 100 seconds

T5LAC Timer during which the congestion messages for the couple (BSC, LAC) are
ignored
• Symbolic input and output parameter name
• Parameter value: 1 up to 100 seconds

T6BSC Timer beyond which the BSC congestion is considered as over


• Symbolic input and output parameter name
• Parameter value: 1 up to 100 seconds

T6LAC Timer beyond which the congestion of the couple (BSC, LAC) is considered as
over

1AA 00014 0004 (9007) A4 – ALICE 04.10

Symbolic input and output parameter name


• Parameter value: 1 up to 100 seconds

UKN Unknown

ED 02

3BL 33096 CCAA ADAHA 58 / 60

60
• NUMTYP input and output parameter value
• NUMPL input and output parameter value

UNALLLAC LACs values either non authorized or having to be put off from the regional sub-
not permitted without written authorization from Alcatel.

scription zone code


All rights reserved. Passing on and copying of this
document, use and communication of its contents

• Symbolic input parameter name


• Parameter value: from 1 to 65533
The zero value (only accepted by the MODZOC command) allows to delete the code from the
regional subscription zone

UNEQ Management by BSC of ”Unequipped Circuit” message


• BSCTYP input and output parameter value

UNL Synchronization failure between the clocks of the DTRX and CALX boards
• TYPFAU output parameter value

UNMSGR Unexpected message received


• OBCFAU output parameter value

USEDRES Result used by analyses or results of ”result depending on length” type


• Symbolic input parameter name
• Parameter value: from 1 to 4000 or from 1 to 12000 according to an option

VERSHDL Entity address analysis in order to determine the key to access the MAP ver-
sions data.
• ORIG input and output parameter value

VERSION Application context version used in the outgoing dialogues


• Symbolic input and output parameter name
• Parameter value:
V1 : version 1
V2 : version 2
V3 : version 3
NSUP : application context not existing in V1 and not supported by the foreign network
Default value at creation : for each application context the lowest version supported by the sys-
tem
Consult the APCTX parameter in order to know the minimum and maximum versions supported
by the system for each application context

VLRDPC Destination point code of the adjacent VLR


• Symbolic input and output parameter name
• Parameter value: from 0 up to 16383 or from 0 up to 16777215 according to the length of the
address used in the network.

VLRGA Global address of the adjacent VLR


• Symbolic input and output parameter name
• Parameter value: from 1 to 999999999999999 (maximum 15 digits)

VLRRET Inter VLR information retrieval


• APCTX and RAPCTX input and output parameter value

VMSCFW Call forwarding number from VLR


• ORIG input and output parameter value
1AA 00014 0004 (9007) A4 – ALICE 04.10

VPLMN Visited PLMN


• PLMN input and output parameter value

ED 02

3BL 33096 CCAA ADAHA 59 / 60

60
VSCADD SC address received from the mobile subscriber in VMSC
• ORIG input and output parameter value

V1 to V3 Version 1, 2 or 3 for application context


not permitted without written authorization from Alcatel.

• VERSION and RVERSION input and output parameter value


All rights reserved. Passing on and copying of this
document, use and communication of its contents

WAN Indication of connection of broadcast channel as soon as the call is established


• Symbolic input and output parameter name
• Parameter value:
Y : Connection
N : No connection (default value)

WZON World zone identification


• Symbolic input and output parameter name
• Parameter value: 1 up to 9
Default value = Identification number of the world zone of the HPLMN country (PLMN data)
0 to delete the parameter value

ZCVAL Value of the regional subscription zone code


• Symbolic input and output parameter name
• Parameter value: 4 hexadecimal characters (32 zone codes maximum)

ZCVAL Value of the fixed area


• Symbolic input and output parameter name
• Parameter value: 4 hexadecimal characters (2048 zone codes maximum)
END OF DOCUMENT
1AA 00014 0004 (9007) A4 – ALICE 04.10

ED 02

3BL 33096 CCAA ADAHA 60 / 60

60

You might also like