HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Utilization of dictionary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DICTIONARY OF MNEMONICS
MXM Dictionary
RCP R7.2 – MNERCP
ED 02
60
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization from Alcatel.
1AA 00014 0004 (9007) A4 – ALICE 04.10
ED
HISTORY
02
3BL 33096 CCAA ADAHA
60
2 / 60
1 INTRODUCTION
The present document provides the list of mnemonics used in operator commands for the operation and
maintenance of RCP.
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
When a symbol defines a parameter used in input, ”Symbolic input parameter name” is specified.
When a symbol defines a parameter used in output, ”Symbolic output parameter name” is specified.
When a symbol defines a parameter used in both input and output ”Symbolic input and output parameter
name” is specified
When a symbol is used several times and each time with the same meaning, it is only defined once.
When a symbol is used several times and each time with a different meaning, specific mention is made
each time the meaning differs.
1AA 00014 0004 (9007) A4 – ALICE 04.10
ED 02
60
2 ALPHABETIC LIST OF MNEMONICS
ADDSCCP Rank and Digits to be inserted in the SCCP Called Party Address
• Symbolic input and output parameter name
• Parameter value: rk–digits
– rk : from 0 to 16, 0 indicates no addition of any digits. If rk is greater than the number length,
then the digits are to be inserted at the end of the number.
– digits : 1 to 8 digits ( not significant if rk = 0 )
ALL Same MSRN pool for all mobiles (INTER and INTRA)
• ROAMTYP input and output parameter value
MS : when both rates are used, the MS choice for rate and speech versions is kept unchanged
ED 02
60
• Symbolic input and output parameter name
• Parameter value:
NONE : the BSC does not support AMR (default value)
FR : if supported by the MS, the AMR codecs are only used in Full Rate mode
not permitted without written authorization from Alcatel.
HR : if supported by the MS, the AMR codecs are only used in Half Rate mode
All rights reserved. Passing on and copying of this
document, use and communication of its contents
BOTH : the AMR codecs are used in both Full and Half Rate modes
NWUSSH = V2
SMGWAY = V1, V2 and V3
SMMORL = V1, V2 and V3
SMTCRL = V2 and V3
ED 02
60
SMWDTM = V1 and V2
VLRRET = V2
LOCRET =V3 (on option)
CCOTRA = V3
not permitted without written authorization from Alcatel.
REPORT = V3
All rights reserved. Passing on and copying of this
document, use and communication of its contents
CCOMP = V3
SSNOTI = V3
AUFAIL = V3
ATTACH ”attach” state of the subscriber (the subscriber is tied to a mobile station)
• SBSTAT output parameter value
ED 02
60
BS41 = Data service: asynchronous PAD access (300 bits/s)
BS42 = Data service: asynchronous PAD access (1200 bits/s)
BS44 = Data service: asynchronous PAD access (2400 bits/s)
BS45 = Data service: asynchronous PAD access (4800 bits/s)
not permitted without written authorization from Alcatel.
BOTH AMR codecs used are Full Rate and Half Rate modes
• AMRRATE input and output parameter value
ED 02
60
BS Basic Service. Accepted PLMNs management
• Symbolic output parameter name
• Parameter value:
SPEECH = Speech (TS10 basic service group)
not permitted without written authorization from Alcatel.
ED 02
60
BS46 = Data service: asynchronous PAD access (9600 bits/s)
BS61 = Data service: alternate speech–data (300/9600 bits/s)
BS81 = Data service: speech followed by data (300/9600 bits/s)
not permitted without written authorization from Alcatel.
ED 02
60
– CIMEI Management of ”Ciphering Mode Command” message with IMEI request (Default
value)
– NCIMEI Management of ”Ciphering Mode Command” message without IMEI request
g = management type for ”MSC Invoke Trace” message
not permitted without written authorization from Alcatel.
g values:
All rights reserved. Passing on and copying of this
document, use and communication of its contents
p values:
– TCM2 ”Class Mark 2” IE truncated to 4 octets in ”Handover Request” message (Default
value)
– NTCM2 ”Class Mark 2” IE not truncated in ”Handover Request” message
ED 02
60
q = Giving the value of the bit 1 of ”downlink DTX” IE in the messages ”Assignment request”
and ”Handover request”
q values:
– DLDTX0 bit 1 of ”downlink DTX” IE set to 0 (the MSC allows the BSS to activate DTX in
not permitted without written authorization from Alcatel.
the downlink direction) in the messages ”Assignment request” and ”Handover request”
All rights reserved. Passing on and copying of this
document, use and communication of its contents
– DLDTX1 bit 1 of ”downlink DTX” IE set to 1 (the MSC forbids the BSS to activate DTX in
the downlink direction) in the messages ”Assignment request” and ”Handover request”
(Default value)
r = Inclusion in the message HO–Request of the parameter ”Old BSS to new BSS information”
r values:
– NIBSSI the parameter ”Old BSS to new BSS information” is not included (Default value)
– IBSSI the parameter ”Old BSS to new BSS information” is included
s = Dual Transfer Mode support
s values:
– DTM the BSC supports DTM mobiles
– Default value is NDTM, the BSC does not support DTM mobiles.
Note 1) The input order of values doesn’t matter (a+n or n+a), only one ”a” and/or ”b” and/or
”n” type value is accepted. In the answer the edited values are always in the a+b+...n order.
Note 2) In the BSC type modification case, only the provided values (a and/or n) will be modified,
the other ones (a and/or n) not provided values stay unmodified.
Note 3) PHASE1 and PHASE2 values are not accepted both. The BSCTYP value may be:
PHASE(1 or 2)+a+...n in this case the values (a to n) provided are in place of the ones defined
by PHASE1 or PHASE2 provided. Example:
BSCTYP=PHASE2+NUNEQ+NIVTR gives the result:
LAI+HORR+CLMU+HOCI+CONF+CIMEI+NIVTR+HCAUS+CLMI2+NUNEQ+
DR, FR, FRMSV or DRMSV+CLMI3+CHAN+LDIND+ICCH+NTCM2+DLDTX1+IBSSI + NDTM
Note 4) In edition the values are on exactly 6 characters, (with filling blanks if necessary).
BS21 Data service: asynchronous data circuit (300 bit/s), basic service
• BS input and output and BEARS and OBSCRI output parameter value
ED 02
60
BS22 Data service: asynchronous data circuit (1200 bit/s), basic service
• BS input and output and BEARS and OBSCRI output parameter value
BS24 Data service: asynchronous data circuit (2400 bit/s), basic service
not permitted without written authorization from Alcatel.
• BS input and output and BEARS and OBSCRI output parameter value
All rights reserved. Passing on and copying of this
document, use and communication of its contents
BS25 Data service: asynchronous data circuit (4800 bit/s), basic service
• BS input and output and BEARS and OBSCRI output parameter value
BS26 Data service: asynchronous data circuit (9600 bit/s), basic service
• BS input and output and BEARS and OBSCRI output parameter value
BS31 Data service: synchronous data circuit, 1200 bits/s basic service
• BS input and output and BEARS and OBSCRI output parameter value
BS32 Data service: synchronous data circuit, 2400 bits/s basic service
• BS input and output and BEARS and OBSCRI output parameter value
BS33 Data service: synchronous data circuit (4800 bit/s), basic service
• BS input and output and BEARS and OBSCRI output parameter value
BS34 Data service: synchronous data circuit, 9600 bits/s basic service
• BS input and output and BEARS and OBSCRI output parameter value
ED 02
60
Y = Use of CAMEL services allowed, default value at creation time
N = Use of CAMEL services not allowed
ED 02
60
CAX Subscriber category– Charging category
• Symbolic input and output parameter name
• Parameter value with form : a–b with :
a = Subscriber category,
not permitted without written authorization from Alcatel.
HB = Hot Billing
ORD = Ordinary
b = Charging category
value from 0 to 32 (a zero value means an undefined category)
If a=ORD , b must not be equal to zero).
CBOIEXHC Barring of all Outgoing international calls except those directed to the home
PLMN country
• ASUPS and SSUPS input and output parameters value
• OPQSS output parameter value
CC Country Code of the analised number, used by SOR to check the charging
requirements (CC is mandatory when NDCOR is provided)
• Symbolic input and output parameter name
• Parameter value: up to 3 digits,
000 : to delete the parameter value
CD Call Deflection
• SSCSI output parameters value
ED 02
60
• OPQSS output parameter value
CH Call Hold
• ASUPS and SSUPS input and output parameters value
ED 02
60
CHGINT Charging category ”charging with international type tariff”
• CGCAT input and output parameter value
CIMEI Management by BSC of the ”Ciphering Mode Command” message with IMEI
request
• BSCTYP input and output parameter value
CLITC Calling Line Identification analysis or analysis of the number forwarding the call
or analysis of the call forwarding number for an incoming call or analysis of the
call transfer number for an incoming call
• ORIG input and output parameter value
1AA 00014 0004 (9007) A4 – ALICE 04.10
ED 02
60
CLMI3 Management by BSC of parameter ”Classmark Info3” in ”Handover Request”
message
• BSCTYP input and output parameter value
not permitted without written authorization from Alcatel.
COLOC Connected Line Identification analysis or analysis of the number forwarding the
call or analysis of the call forwarding number for an outgoing call or analysis of
the call transfer number for an outgoing call
• ORIG input and output parameter value
CRC41 The number of multiframes received with a wrong CRC4 indicates an error bit
rate greater than 10–3 (analysis during 1 s).
• TYPFAU output parameter value
CRC42 The number of multiframes with a wrong CRC4 indicates an error bit rate
greater than 10–6 (analysis during 1 minute).
• TYPFAU output parameter value
ED 02
60
• Parameter value:
FWD = Forwarding call
OC = Originating call
ALL = Both call types (OC and FWD)
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
CUGBSG Basic Service Group for Closed Users Group supplementary service
• Symbolic output parameter name
• Parameter value:
SPEECH = Speech transmission
TS60 = Fac simile service
BS20 = data services, duplex asynchronous circuit
BS30 = data services, duplex synchronous circuit
CW Call waiting
• ASUPS and SSUPS input and output parameters value
• OPQSS output parameter value
ED 02
60
DELIND Deleted dialling code
• Symbolic output parameter name
• Parameter value: from 1 to 31 digits (0 to 9, A and B)
Take in account that A is used to code * and B to code #
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
DETACH ”detach” state of the subscriber (the subscriber is not tied to a mobile station)
• SBSTAT output parameter value
DLDTX0 Bit 1 of ”downlink DTX” IE set to 0 in the messages ”Assignment request” and
”Handover request”
• BSCTYP input and output parameter value
DLDTX1 Bit 1 of ”downlink DTX” IE set to 1 in the messages ”Assignment request” and
”Handover request”
• BSCTYP input and output parameter value
DONE Routing number used for portability has been recognised in the analysed
1AA 00014 0004 (9007) A4 – ALICE 04.10
number
• NPDBQ input and output parameter value
ED 02
60
DR Dual Rate speech version 1 BSC: assignement of Full Rate or Dual Rate version
1 channel by the BSC.
• BSCTYP input and output parameter value
not permitted without written authorization from Alcatel.
DRMSV Dual Rate multi speech version BSC: assignement of Full Rate or Dual Rate
All rights reserved. Passing on and copying of this
document, use and communication of its contents
Note (1) : Only if ’Specific routing for Tandem Free Operation(TFO)’ is offered.
ERR1 The error bit rate has reached 10–3 (count during 1 second the errors in the
frame alignment signal)
• TYPFAU output parameter value
ERR2 The error bit rate has reached 10–5 (count during 1 minute the errors in the
frame alignment signal)
• TYPFAU output parameter value
ED 02
60
E3 Conversion factor (expressed in 1/100) between the units of the HPLMN and
the LPLMN
• Symbolic input and output parameter name
• Parameter value: from 0 to 8191
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
FR Full Rate speech version 1 only BSC: assignement of Full Rate version 1 chan-
nel by the BSC
• BSCTYP input and output parameter value
FRMSV Full Rate multi speech version BSC: assignement of Full Rate multi version
channel by the BSC
• BSCTYP input and output parameter value
ED 02
60
• Symbolic input and output parameter name
• Parameter value:
Y = Forwarding violation allowed (only if the corresponding option is offered)
N = Forwarding violation not allowed (default value)
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
GAN Geographical area number for a group of cells in GSM environment or service
area in UMTS environment
• Symbolic input and output parameter name
• Parameter value: from 1 to 255
– up to 64 when the SSP type is an E10MT
– up to 127 when the SSP type is an E10B
– up to 255 when the SSP type is an OCB283
ED 02
60
HLRROUT HLR request (type of result)
• TYPE input and output parameter value
HR AMR codecs are only used in Half Rate mode, if supported by the MS
• AMRRATE input and output parameter value
IBSSI Inclusion in the message HO–Request of the parameter ”Old BSS to new BSS
information”
• BSCTYP input and output parameter value
ED 02
60
MSIN= Mobile Subscriber Identification Number: from 4 to 9 or 10 digits according to the num-
bering plan.
• Input parameter value: in input the IMSI parameter is not segmented. Moreover it may be trun-
cated on right in order to indicate an IMSI group signalled by their first digits. When this input
not permitted without written authorization from Alcatel.
INS Rank of digit and number of digits of the additional number to be inserted
ED 02
60
• Symbolic input and output parameter name
• Parameter value: rk–nb
rk : absolute rank between 1 and 20
nb : between 1 and 20
not permitted without written authorization from Alcatel.
INSLAC Rank of the digit (rk) and number of digits (nb) of the location to be inserted.
• Symbolic input and output parameter name
• Parameter value: rk–nb
rk : absolute rank from 1 to 10 depending on option, or from 1 to 16 depending on option
nb : from 1 to 10
with rk+nb less than or equal to 11 depending on option, or 17 depending on option
0 for nb to delete the parameter value
INTE International
• NUMTYP input and output parameter value
IOA All the terminating and outgoing calls authorized for CUG
• CUGRES output parameter value
ED 02
60
IWFTYP Inter Working Function type
• Symbolic input and output parameter name
• Parameter value: SPEECH, IWF1, IWF2, IWF3, IWF4
not permitted without written authorization from Alcatel.
LAC Location Area Code, management by BSC / RNC of LAC value, to identify all
the cells or service areas within a location area.
• BSCTYP / RNCTYP input and output parameter value
LAI Location Area Identification, management by BSC of LAI value, to identify all
the cells within a location area.
1AA 00014 0004 (9007) A4 – ALICE 04.10
ED 02
60
LATIT Latitude of the cell centre (in GSM environment), or of a service area (in UMTS
environment)
• Symbolic input and output parameter name
• Parameter value: Value with format: degrees–mn–sec–hundreth–direction with:
not permitted without written authorization from Alcatel.
Degrees = from 0 to 90
All rights reserved. Passing on and copying of this
document, use and communication of its contents
Minutes = from 0 to 59
Seconds = from 00 to 59
Hundreth = from 00 to 99
Direction= N (North) or S (South)
LCKNB Lock Number, Number of subscribers with locked data, to forbid them the
access.
• Symbolic output parameter name.
Parameter value: Integer in decimal numbering.
ED 02
60
the result associated to length 21 deals for all lengths in the range 21 to 80.
result from 1 to 4000 or from 1 to 12000 according to an option
To remove a value (length–result) from the list, LISTL=length–0 must be entered.
not permitted without written authorization from Alcatel.
LOCNB Location cell address (in GSM environment), or of a service area (in UMTS
environment)
• Symbolic input parameter name
• Parameter value: 15 digits maximum (format E164)
The default value is either the MSC E164 address or the value of PLMN parameter LOCNB–
DEF depending on a functional option.
LONGIT Longitude of the cell centre (in GSM environment), or of a service area (in UMTS
environment)
• Symbolic input and output parameter name
• Parameter value: Value with format: degrees–mn–sec–hundreth–direction with:
Degrees = from 0 to 180
Minutes = from 0 to 59
Seconds = from 00 to 59
Hundreth = from 00 to 99
Direction= E (East) or W (West)
ED 02
60
N = to list IMSI, MSISDN and HLRNB
MAC The CALX board did not acknowledge the DTRX alarm report (the reinitializa-
tion of the CALX board is probably in progress)
not permitted without written authorization from Alcatel.
ED 02
60
• Symbolic output parameter name
• Parameter value: value of format: number–status with:
Number= MIWX board number
Status= MIWX board status:
not permitted without written authorization from Alcatel.
MPTY Multiparty
• ASUPS input and output parameter value
• SSUPS input and output parameter value
• SSCSI output parameter value
ED 02
60
MSPURG Mobile station purging
• APCTX input and output parameter value
MSR The DTRX board does not send any more alarm report to the CALX board
not permitted without written authorization from Alcatel.
NATIO National
• ADDNAT input and output parameter value
• NID input and output parameter value
• NUMPL input and output parameter value
• NUMTYP input and output parameter value
NCLMI3 Management by BSC of the ”Handover Request” message without the ”Class-
mark Info3” parameter
• BSCTYP input and output parameter value
NDCOR National Destination Code of the analised number, used by SOR function to
check the charging requirements (the parameter CC must be provided in this
case)
• Symbolic input and output parameter name
• Parameter value: up to 4 digits (0 to 9), 0000 value to delete the parameter value
NETWORK Number coming from RTC (incoming call received by the gateway)
• ORIG input and output parameter value
1AA 00014 0004 (9007) A4 – ALICE 04.10
NHCAUS Management by BSC of the ”Handover Request” message without the ”Cause”
parameter
• BSCTYP input and output parameter value
ED 02
60
NHOCI Management by BSC of the ”Handover Command” message without the identi-
fication parameter of the target cell
• BSCTYP input and output parameter value
not permitted without written authorization from Alcatel.
NIBSSI Not inclusion in the message HO–Request of the parameter ”Old BSS to new
All rights reserved. Passing on and copying of this
document, use and communication of its contents
BSS information”
• BSCTYP input and output parameter value
NO The analysed number does not match a call charging type with special tariff
(Premium Rate)
• PRMRATE input and output parameter value
Y : Numeration forbidden
N : Numeration not forbidden (default value)
ED 02
60
• Symbolic input and output parameter name
• Parameter value:
DONE : A NPDB query has already been done in an upstream exchange,
this value is set when a routing number used for portability has been
not permitted without written authorization from Alcatel.
NPNA Numbering plan and nature of address for a Non–E.164 forwarded_to number
• Symbolic output parameter name
• Parameter value: 2 hexadecimal characters
ED 02
60
RNNAT = Network routing number in national number format
RNSPE = Network routing number in network–specific number format
ED 02
60
GBS30 = Data service: synchronous data circuit (general bearer service)
BS40 = Data service: PAD access (Basic service group)
BS41 = Data service: asynchronous PAD access (300 bits/s)
BS42 = Data service: asynchronous PAD access (1200 bits/s)
not permitted without written authorization from Alcatel.
ED 02
60
NO APPLICATION PROCEDURE
COUT PORT WRITE FAILURE
ODBOZEH Barring of all outgoing inter–zone calls except those directed to the home PLMN
country
ODBSSM Barring of supplementary services management
ED 02
60
ODBCT Barring of invocation of call transfer
• ODBCAT output parameter value
ODBCTC Barring of invocation of call transfer where at least one of the two calls is a call
not permitted without written authorization from Alcatel.
ODBCTI Barring of invocation of call transfer where at least one of the two calls is a call
charged to the served subscriber at international rate, namely the call charged
is either an ougoing international call or an incoming call when the served sub-
scriber roams outside the PLMN country
• ODBCAT output parameter value
ODBCTZ Barring of invocation of call transfer where at least one of the two calls is a call
charged to the served subscriber at inter–zone rate, namely the call is either an
outgoing inter–zone call or an incoming call when the served subcriber roams
in a VPLMN in a zone different from the HPLMN
• ODBCAT output parameter value
ODBOIEH Barring of all outgoing international calls except those directed to the home
PLMN country
• ODBCAT output parameter value
ODBOIHZ Barring of all outgoing international calls except those directed to the home
PLMN country and barring of outgoing inter–zone calls
• ODBCAT output parameter value
ODBOZEH Barring of all outgoing inter–zone calls except those directed to the home PLMN
country
• ODBCAT output parameter value
ED 02
60
• Symbolic output parameter name
• Parameter value: from 1 to 4000 or from 1 to 12000 according to an option
OOR Own oscillator’s controlled voltage of the CALX board is at upper or lower limit
not permitted without written authorization from Alcatel.
MAPMSRN = Translator call in the MSC gateway with a MSRN from HLR
MOBILE = Number asked by a mobile subscriber (outgoing call)
NETWORK = Number asked from RTC (incoming call received by the gateway)
ED 02
60
NU = Deletion of the parameter value (in input only)
ORIGCD = First called number analysis
SCP = Called Party number from an SCP
SERVKEY = Analysis of the key for the SCP address retrieve service
not permitted without written authorization from Alcatel.
VERSHDL = Entity address analysis to determine the access key to the MAP versions data
VMSCFW = Forwarded–to number from a VLR
VSCADD = SC address (service center) received from mobile subscriber in MSC for for-
warding to SMS–IWMSC (Interworking of short messages service)
ORIGCDS Substitution of call forwarding mobile number for first called number
• Symbolic input and output parameter name
• Parameter value:
Y : Substitution
N : No substitution
NU: to delete the parameter value
OVERCS Override either all types of carrier selection or only the carrier selected at sub-
scription
• Symbolic input and output parameter name
• Parameter value:
Y : override all types of carrier selection
SUBSCR : override the carrier selected at subscription
N : no overriding (default value)
PADPROF PAD profile number Stands for a set of predefined PAD parameters in the exter-
nal PAD equipment
• Symbolic input and output parameter name
• Parameter value: from 0 to 99 (default value = 0)
the values between 6 and 99 are reserved
Parameter value:
up to 16 alphanumeric characters and ”_”
ANN_CCBSRQ_NPCP = Announcement number for a MS which does not support PCP to indi-
cate that a CCBS request is possible
ED 02
60
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 2047, value 0 for ”no announcement”)
CA_TNRY = CAMEL timer (in secons, step 5) indicating the duration for the NoAn-
swer event required for arming EDP in the gsmSSF.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 5 up to 40, the value must be a multiple of 5,
default value=25)
CG_F_ITM_TIM_HB = Delay before the first intermediate charging report generation with
hot billing ticket, expressed in seconds
(Value of type: DECVAL or HEXVAL)
(Minimum value of DECVAL = 180, default value=180)
CGAP_OC_MAX = Maximum value of the counter of ”call gaping” OC calls per CPU.
(Value of type: DECVAL or HEXVAL)
1AA 00014 0004 (9007) A4 – ALICE 04.10
CGAP_RED_RAT = Ratio to be applied to the ”call gaping” counter at the end of each
period CGAP_PERIOD. (C = C x CGAP_RED_RAT / 100).
ED 02
60
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 99, default value=50)
DEFAULT_INAP = Default value used when the Service Key is not found in
not permitted without written authorization from Alcatel.
INAP_TAB_SK_XX
All rights reserved. Passing on and copying of this
document, use and communication of its contents
FAX_NT_TIMER = Timer defined in GSM REC 03.46 to process fax in non transparent
mode.
Used to initialize the SMIM.
This value depends on the transmission delay. It must be provided
in the case of satelite transmissions.
Unit : 10ms
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 255 (2550ms), 30 (300ms) default value
ED 02
60
(Value of VERSION = V1, V2, V3 or NSUP ”not supported version”)
INAP_TAB_AC_XX Table of the INAP protocols to be used between the RCF and an
intra–PLMN SCF
not permitted without written authorization from Alcatel.
index XX (INAP_TAB_SK_XX)
(Value of type: DECVAL or HEXVAL)
Numerical value: 1 or 2
1 = CAMEL (default)
2 = IN–SCF–V1
LGC_SUP_TIM_HB = Long call supervision timer for calls with hot billing, expressed in
quarters of hour
(Value of type: DECVAL or HEXVAL)
(Minimum value of DECVAL = 0 ”no supervision”)
(Maximum value of DECVAL = 72 ”18 hours”, default value=72)
ED 02
60
(Value of DECVAL = 1 or 2, default value=2)
NB_PAG_ATTEMPT is allowed when ”HPA after n paging attempts”
option is active.
not permitted without written authorization from Alcatel.
NPDB_ADD_MNP Number Portability Date Base ISDN address used as SCCP called
party address to query the NPDB when the Mobile Number Portabil-
ity is based on IN.
(Value of type: ADDNAT, ISDNNB)
NOREPLY_TIM = Default value for the no reply condition timer, expressed in seconds
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 5 up to 30, default value=20)
(the value must be a multiple of 5)
ED 02
60
(Value of type: VERSION)
(Value of VERSION = V1, V2, V3 or NSUP ”not supported version”)
SM_PREF_PATH = The prefered delivery path for short message in the SMS–GMSC.
(Value of type: BOOLVAL)
(Value of BOOLVAL )
(TRUE= means ”via VMSC” )
(FALSE= means ”via SGSN”, default value )
ED 02
60
TFSAT_T4 Timer to be used for transparent fax with satellite transmissions.
Timer to avoid retransmission of a command if a response has been
received.
Provided to the SMIM at initialisation time.
not permitted without written authorization from Alcatel.
(unit: 100ms)
(Value of DECVAL = from 0 up to 255 ( 25500ms), 25 ( 2500ms)
default value)
ED 02
60
(default value for SATCOM=120)
THPA is allowed when ”High Penetration Alerting” option is active.
TONE_CCBSRQ_NPCP= Tone number for a MS which does not support PCP to indicate that
a CCBS request is possible
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 127)
TONE_CCBSRQ_PCP = Tone number for a MS which supports PCP to indicate that a CCBS
request is possible
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 127)
TONE_INSERT_TIME = CAMEL timer (in seconds, step 5). When set to ”x” value, it indicates
that the RCF must insert a tone ”x” seconds before the end of the call.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 5 up to 60, default value : 30, the value must be
a multiple of 5)
TONE_RECALL_CCBS= Tone number for a MS which does not support CMSP to indicate that
it is a CCBS recall
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 1 up to 127)
TT_SRF_MNP Translation Type value set in the SCCP called party address of call
1AA 00014 0004 (9007) A4 – ALICE 04.10
ED 02
60
TY_NUM_INTCS = Type of number for international calls with carrier indication. This
value is sent on INAP interface when the translation result
(MODTRR) indicates : NUMTYP=INTCS.
not permitted without written authorization from Alcatel.
TY_NUM_INTRA = Type of number for intra–PLMN calls (SOR) without carrier indica-
tion. This value is sent on INAP interface when the translation result
(MODTRR) indicates : NUMTYP=INTRA.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 127, default value : 125)
TY_NUM_INTRACS = Type of number for intra–PLMN calls (SOR) with carrier indication.
This value is sent on INAP interface when the translation result
(MODTRR) indicates : NUMTYP=INTRACS.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 127, default value : 124)
TY_NUM_NATCS = Type of number for national calls with carrier indication. This value
is sent on INAP interface when the translation result (MODTRR) indi-
cates : NUMTYP=NATCS.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 127, default value : 116)
TY_NUM_RES1 to RES4 = Types of numbers in reserve for national use. These values are
sent on INAP interface when the translation result (MODTRR) indi-
cates : NUMTYP=RES1 to RES4.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 127)
(Default values : RES1=112, RES2=113, RES3=114, RES4=115)
T1_CCBS = Time, in seconds, during which a subscriber may ask for a ccbs
request when his call has failed due to busy called subscriber.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 15 up to 120, default value=30)
ED 02
60
(Value of type: DECVAL or HEXVAL)
(unit: 10ms.)
(Value of DECVAL = from 0 up to 255 (2550ms), 52 (520ms) default
value)
not permitted without written authorization from Alcatel.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
T4_CCBS = Time, in seconds, during which a subscriber who is idle and who has
asked for a CCBS request may accept the recall.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 20 up to 30, default value=25)
T10_CCBS= Time, in seconds, during which a subscriber who is busy and who has
asked for a CCBS request may accept the recall.
(Value of type: DECVAL or HEXVAL)
ED 02
60
(Value of DECVAL = 20 up to 30, default value=25)
W_IWF_MS_RLP2 = RLP version 2 window size from IWF to MS. Used to initialize the
SMIM. This value is used by the IWF to negotiate the window size
from IWF to MS.
The value must be a multiple of 8.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 480, default value: 240)
W_MS_IWF_RLP2 = RLP version 2 window size from MS to IWF. Used to initialize the
SMIM. This value is used by the IWF to negotiate the window size
from MS to IWF.
The value must be a multiple of 8.
(Value of type: DECVAL or HEXVAL)
(Value of DECVAL = 0 up to 480, default value: 240)
ED 02
60
Up to 32 values can be defined, including default value ’PLMN’
Note (1) Only if ’Mobile Number Portability’ function is offered.
PRMRATE Premium Rate (Call with special tariff type to kiosk or server)
• Symbolic input and output parameter name
• Parameter value:
PRE : Charged call of entertainment type
PRI : Charged call of information type
NO : The number analysis does not match one of these types
NU : to delete the parameter value
RADIUS Radius of the cell (or a set of cells), (in GSM environment), or of a service area
(in UMTS environment).
• Symbolic input and output parameter name
• Parameter value: between 0 and 1800000 (expressed in meters)
• The value 0 is only allowed in MODREV command to delete the LATIT, LONGIT and RADIUS
values.
fied. The RANA value must be given depending on the remaining digits to be translated after
modification.
ED 02
60
• Symbolic input and output parameter name
• Value of parameter:
Application contexts supported by the system:
AUFAIL = Authentication Failure Report
not permitted without written authorization from Alcatel.
REPORT Reporting
• APCTX and RAPCTX input and output parameter value
ED 02
60
RES1 to RES4 Reserved values 1 to 4 for national use
• NUMTYP input and output parameter value
RIMSI Rank of the digit where all or part of IMSI must be inserted
not permitted without written authorization from Alcatel.
• Parameter value: absolute rank from 1 to 80 (Default value 1 if INIMSI parameter provided)
RINS Rank of the digit where all or part of the additional number must be inserted
• Symbolic input and output parameter name
• Parameter value: absolute rank from 1 to 80
• Default value 1 if INS provided.
RJA The PCM link is seen faulty by the remote entity (SSP) (loss of frame alignment)
• TYPFAU output parameter value
RLAC Rank of the digit where all or part of the location (LAC+CI in GSM, or LAC + SAC
in UMTS ) shall be inserted
• Symbolic input and output parameter name
• Parameter value: absolute rank between 1 and 80
• Default value 1 if INSLAC is provided
• Parameter value:
– ALL : the same pool for INTER (foreign mobile) and INTRA (national mobile)
– INTER : pool for foreign mobiles
– INTRA : pool for national mobiles
ED 02
60
The ALL value is available or not depending on the PLMN.
RPAD Loss of the clock provided by the associated CALX board (VCO) voltage con-
trolled oscillator output
• TYPFAU output parameter value
SAMEKEY Indication of the analysed number used as key to determine the MAP version
• Symbolic input and output parameter name
• Parameter value:
Y : The analysed number is the key for determining the MAP version; in this case the MAPKEY
parameter must be not provided.
N : The analysed number is not the key for determining the MAP version (default value) in this
case the MAPKEY parameter must be provided.
SERVKEY Analyse of the key of the service eabling the SCP address retrieval
• ORIG input and output parameter value
ED 02
60
SINENQ Subscriber data enquiry
• RAPCTX input and output parameter value
SK Key service
not permitted without written authorization from Alcatel.
SN Subscriber Number
• NUMTYP input and output parameter value
ED 02
60
SSNOTI Supplementary services notification requested
• APCTX input and output parameter value
time)
N = Supplementary service COLP forbidden for customer in roaming.
ED 02
60
STCOLR Authorization / prohibition of the supplementary service COLR for customer in
roaming (accepted PLMN administration)
• Symbolic input and output parameter name
• Parameter value:
not permitted without written authorization from Alcatel.
Y = Supplementary service COLR allowed for customer in roaming (default value at creation
All rights reserved. Passing on and copying of this
document, use and communication of its contents
time)
N = Supplementary service COLR forbidden for customer in roaming.
SUBADR Subaddress
• Symbolic output parameter name
• Parameter value: from 4 to 42 hexadecimal characters
ED 02
60
• Parameter value: TMSI age in format: number of days, hours, minutes and seconds
ED 02
60
For DTRX
AIS : Reception of continuous ”1” on the PCM link.
CRC41: The number of multiframes received with a wrong CRC4 indicates an error bit rate
greater than 10–3 (analysis during 1 s).
not permitted without written authorization from Alcatel.
CRC42: The number of multiframes with a wrong CRC4 indicates an error bit rate greater than
All rights reserved. Passing on and copying of this
document, use and communication of its contents
T5BSC Timer during which the BSC congestion messages are ignored
• Symbolic input and output parameter name
• Parameter value: 1 up to 100 seconds
T5LAC Timer during which the congestion messages for the couple (BSC, LAC) are
ignored
• Symbolic input and output parameter name
• Parameter value: 1 up to 100 seconds
T6LAC Timer beyond which the congestion of the couple (BSC, LAC) is considered as
over
•
1AA 00014 0004 (9007) A4 – ALICE 04.10
UKN Unknown
ED 02
60
• NUMTYP input and output parameter value
• NUMPL input and output parameter value
UNALLLAC LACs values either non authorized or having to be put off from the regional sub-
not permitted without written authorization from Alcatel.
UNL Synchronization failure between the clocks of the DTRX and CALX boards
• TYPFAU output parameter value
VERSHDL Entity address analysis in order to determine the key to access the MAP ver-
sions data.
• ORIG input and output parameter value
ED 02
60
VSCADD SC address received from the mobile subscriber in VMSC
• ORIG input and output parameter value
ED 02
60