You are on page 1of 3

1280 HIGHTOWER TRAIL

ATLANTA, GA 30350
PHONE: 770.864.1035
dwelldesignstudio.com

.2
1-11 LL
A
1/ E WA
FI R
R
3-H

3300
4"

1"
2"
8' -

' '--0
'-
18

4"

"
1

1"
1"
2 A4-14
4 " 2
5' -
G083

62
1

FAIRFIELD AT PIEDMONT
'-
A6-07B S2B

4"
"

6"
5' - 3
WB1
" 070 135.00°
5' -2 B18
11
" G086
RFI 69
7' - A4A G079
" A4

32
'- 11

1950 PIEDMONT CIRCLE NE


'-
13 WB1

2"
WB1 070
1" 070

ATLANTA, GA 30324
TYP
1
A5-06 WB1

10
032 G084

'-
0 "

41
3 8' - PB3 B3A

/2"
070

6' -
4"

0"
2 0"

1"

5' -
6' -
1"

5"
2
A2-10A ELEC -10' - 8 5/8"
"
2" '- 10 G075
'- 23
69 B4A

5' -
1 2 WB1
2 WB1
MECH

11
A2-30 070 070
1"

1/2
"
ELEV 1 G082

10
" STOR G080 S2A
'- WB2
23 040 A2

7' -
A4-20

83
STOR
1" WB1

/4"
3 070 WB1

5' -
G073 070

ST
TYP A DEVELOPMENT FOR:

0"
STOR PASS 1
A12B

AIR
8"
THRU '-
A5-05 CORRIDOR 36
0"

A
3 8' -
TYP
2 STOR
G078
WB1 A5-05
A3 1"
070
1"
1 0"
G071 WB1 '-
18 ISSUE
0" A2A 032 2
8' - WB1 DATE DESCRIPTION INCLUDED
1 1 070 A5-11 A5-11 1" 04.30.2021 SCHEMATIC DESIGN SET
G076 05.28.2021 LAND DISTURBANCE PERMIT SET

1" G069 WB1 3 07.02.2021 DESIGN DEVELOPMENT SET X

032 A3.1 08.27.2021 FOUNDATION PERMIT SET


A2A A5-11
1 0"
09.03.2021
10.18.2021
60% CD PROGRESS SET
PERMIT SET / GMP
X
X
A4-20 2 3' - 11.24.2021
12.22.2021
ADDENDUM A1
PERMIT REPRINT
2 01.28.2022 PROGRESS SET X
TYP G074 1 " 08.10.2022 ISSUED FOR CONSTRUCTION
1' -
10 4 1 A2-20 1 3/4
1/2 A3 X
" 1.2 WB1 A5-05
1/2
"
A1-1
WB2
"
'-8

5
PB3 1/ 070 042 A5-15
10
'-
070
20

3" /4"
TYP 5' - 13 REVISION
1"

1 WB1 DATE DESCRIPTION REV


G067
4"

2 WB1 WB1 " 01/28/2022 PROGRESS SET 1


A5-06 070 10
"
1"

08/10/2022 IFC SET 2


2 070 B2D '-
'-6
070
23
/2"

A6-07B 3 1
11

ALL
13
ST B18 G072
AIR E W
B FIR 5' - B2 A4-10
3-HR
"

1"
'-2

G059 G065 6"


56

S2D

A4 "
10
90.0

3 '-
ELEV 2 23
MECH WB1 1 A5-13
125.00° G070 070 2
"
1/2

A3.1 A5-13 A5-13 1"


'-4

WB1
STOR B17 070 WB1
2
35

F.1 G061 TYP "


070 10
2 '-
AX4 23
A5-06

MAINT
WB1 1"
G068 070
A3 /8"
91
'-
IDF 3 25
0 "
3 8' -
RISER
WB1
G066 070
1 G058
A3.1
A2-10 A7 TYP 125.00° UP TYP 1"
2 4
2 A5-05 A5-31 0"
SEAL:

1
A5-16 WB1 2 3' -
G064 070
1 2 A3
WB1 G060 1"
10" 070 UP
10 A5-16 B1F 2
'-2 WB1 "
1" "
'- 10
070 23 A4-10
1"
G062
UP
27
'-0 BX2 1"
"
C:\Users\aaragi\Documents\FF Intown_Residential_R20_aaragi.rvt

0"
'-1
23
DISCLAIMER:
WB1 THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE
1" PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE
070 REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS
REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED
96 FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND
'-8 1" ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN
3/4 CONSENT OF DWELL DESIGN STUDIO.
" SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL
DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES.

35
'-6
" 0"
'-1 SHEET NAME:
23
"
7/8

UP

C dwell design studio - ALL RIGHTS RESERVED


2
ENLARGED
10

1" A5-15 1"


4' -

12
'-0
FLOOR PLAN -
5/8
"
3
A5-15 "
LEVEL T1 -
1/8
10
'-1
01 30
'-1
0
AREA 1
/8"

IFC SET
ENLARGED PARTIAL PLAN - LEVEL T1 - AREA 1
1
3/32" = 1'-0" 0' 5' 11' 21' JOB NUMBER: 2103801

DRAWN BY CHECKED BY
Author Checker
8/12/2022 4:34:11 PM

BUILDING KEYPLAN
S
E

A1-11.1
ISSUED FOR CONSTRUCTION
BUILDING CODE DATA - TYPE IA BUILDING CODE DATA - TYPE VA BUILDING CODE DATA - TYPE IIIA
BUILDING OCCUPANCY CLASSIFICATION : A-3, B, R-2 BUILDING OCCUPANCY CLASSIFICATION : R-2 BUILDING OCCUPANCY CLASSIFICATION : R-2
AREA ALLOWED PER FLOOR : (PER T506.2) UNLIMITED SQ.FT. AREA ALLOWED PER FLOOR : (PER T506.2) 36,000 SQ.FT. AREA ALLOWED PER FLOOR : (PER T506.2) 72,000 SQ.FT.
SQ. FT. ALLOWED PER FLOOR AS DETERMINED PER 506.3.3 : UNLIMITED SQ.FT. SQ. FT. ALLOWED PER FLOOR AS DETERMINED PER 506.3.3 : SQ. FT. ALLOWED PER FLOOR AS DETERMINED PER 506.3.3 :

BUILDING TYPE IA AREAS 3000A


Name Level Area BUILDING TYPE VA AREAS 3000B BUILDING TYPE VA AREAS 4000 BUILDING TYPE IIIA AREAS 1000 BUILDING TYPE IIIA AREAS 2000 1280 HIGHTOWER TRAIL
BLDG - 3000A LEVEL 1 4391.65 SF ATLANTA, GA 30350
BLDG - 3000A LEVEL 1 1504.06 SF Name Level Area Name Level Area Name Level Area Name Level Area PHONE: 770.864.1035
BLDG - 3000A LEVEL 1 988.12 SF BLDG - 3000B LEVEL 3 24630.50 SF BLDG - 4000 LEVEL 2 8201.44 SF BLDG - 1000 LEVEL T2 8211.28 SF BLDG - 2000 LEVEL T1 14836.63 SF dwelldesignstudio.com
BLDG - 3000A LEVEL 2 7372.64 SF BLDG - 3000B LEVEL 4 22887.19 SF BLDG - 4000 LEVEL 3 24326.48 SF BLDG - 1000 LEVEL T1 26550.28 SF BLDG - 2000 LEVEL 1 17664.90 SF
BLDG - 3000A LEVEL 2 876.56 SF BLDG - 3000B LEVEL 5 24697.68 SF BLDG - 4000 LEVEL 4 25774.05 SF BLDG - 1000 LEVEL 1 26595.69 SF BLDG - 2000 LEVEL 2 17664.43 SF
BLDG - 3000A LEVEL 2 983.17 SF BLDG - 3000B LEVEL 6 22887.19 SF BLDG - 4000 LEVEL 5 24357.81 SF BLDG - 1000 LEVEL 2 26559.50 SF BLDG - 2000 LEVEL 3 17676.81 SF
BLDG - 4000 LEVEL 6 25774.05 SF BLDG - 1000 LEVEL 3 26559.88 SF BLDG - 2000 LEVEL 4 16613.29 SF
BLDG - 1000 LEVEL 4 28114.78 SF
TYPE OF CONSTRUCTION : IA TYPE OF CONSTRUCTION : VA TYPE OF CONSTRUCTION : IIIA
BUILDING HEIGHT ALLOWANCE (PER 503 & 504.3): UNLIMITED BUILDING HEIGHT ALLOWANCE (PER 503 & 504.3): 70'-0" BUILDING HEIGHT ALLOWANCE (PER 503 & 504.3): 85'-0"
BUILDING HEIGHT PROVIDED : BLDG 3000 A: 21' - 3 3/4" BUILDING HEIGHT PROVIDED : BLDG 3000 B: 41' - 0 3/4" | BLDG 4000: 45' - 2 7/8" BUILDING HEIGHT PROVIDED : BLDG 1000: 55' - 6 7/8" | BLDG 2000: 51 - 8 3/4"
NUMBER OF STORIES ALLOWED (PER 503 & 504.4): UNLIMITED NUMBER OF STORIES ALLOWED (PER 503 & 504.4): 4 NUMBER OF STORIES ALLOWED (PER 503 & 504.4): 5
NUMBER OF STORIES PROVIDED : 2 NUMBER OF STORIES PROVIDED : 4 NUMBER OF STORIES PROVIDED : 5

FIRE RATING : WALLS AND PARTITIONS OPENING PROTECTION FIRE RATING : WALLS AND PARTITIONS OPENING PROTECTION FIRE RATING : WALLS AND PARTITIONS OPENING PROTECTION
FIRE WALLS (PER 706.4): 3 HOUR 3 HR FIRE WALLS (PER 706.4): 2 HOUR 1 1/2 HR "B" LABEL DOORS FIRE WALLS (PER 706.4): 3 HOUR 3 HR 'A' LABEL DOORS
FIRE BARRIERS / STAIR ENCLOSURE RATING (PER 707.3.10): 2 HOUR 1 1/2 HR FIRE BARRIERS / STAIR ENCLOSURE RATING (PER 707.3.10): 2 HOUR 1 1/2 HR "B" LABEL DOORS FIRE BARRIERS / STAIR ENCLOSURE RATING (PER 707.3.10): 2 HOUR 1 1/2 HR 'B' LABEL DOORS
INTERIOR BEARING WALLS (PER 601): 3 HOUR 3 HR INTERIOR BEARING WALLS (PER 601): 1 HOUR 3/4 HR "C" LABEL DOORS INTERIOR BEARING WALLS (PER 601): 1 HOUR 3/4 HR 'C' LABEL DOORS
INTERIOR NON-BEARING WALLS (PER 601): 0 HOUR 0 HR INTERIOR NON-BEARING WALLS (PER 601): 0 HOUR - INTERIOR NON-BEARING WALLS (PER 601): 0 HOUR -
EXTERIOR BEARING WALLS: 3 HOUR 0 HR EXTERIOR BEARING WALLS: 1 HOUR - EXTERIOR BEARING WALLS: 2 HOUR -

FAIRFIELD AT PIEDMONT
EXTERIOR NON-BEARING WALLS: > 30' SEPARATION (PER 602): 0 HOUR 0 HR EXTERIOR NON-BEARING WALLS: > 30' SEPARATION (PER 602): 0 HOUR - EXTERIOR NON-BEARING WALLS: > 30' SEPARATION (PER 602): 0 HOUR -
EXTERIOR NON-BEARING WALLS: < 30' SEPARATION (PER 602): 1 HOUR 3/4 HR EXTERIOR NON-BEARING WALLS: < 30' SEPARATION (PER 602): 1 HOUR - EXTERIOR NON-BEARING WALLS: < 30' SEPARATION (PER 602): 1 HOUR -
CORRIDOR WALLS (PER 1020.1): 0.5 HOUR 20 MIN UNIT DOOR; 3/4 HR ELSEWHERE CORRIDOR WALLS (PER 1020.1): 1 HOUR 20 MIN UNIT DOOR; 3/4 HR ELSEWHERE CORRIDOR WALLS (PER 1020.1): 1 HOUR 20 MIN UNIT DOOR; 3/4 HR ELSEWHERE
STAIR / ELEVATOR SHAFT WALLS (PER 713.4): 2 HOUR 1 1/2 HR STAIR / ELEVATOR SHAFT WALLS (PER 713.4): 2 HOUR 1 1/2 HR "B" LABEL DOOR STAIR / ELEVATOR SHAFT WALLS (PER 713.4): 2 HOUR 1 1/2 HR B DOOR
REFUSE CHUTE SHAFT WALLS (PER 713.13.1): 2 HOUR 1 1/2 HR REFUSE CHUTE SHAFT WALLS (PER 713.13.1): 2 HOUR 1 1/2 HR "B" LABEL DOOR REFUSE CHUTE SHAFT WALLS (PER 713.13.1): 2 HOUR 1 1/2 HR B DOOR
REFUSE ACCESS 1 HR, 713.13.3 / TERMINATION ROOMS 2 HR, 713.13.4: 1 HOUR 3/4 HR REFUSE ACCESS 1 HR, 713.13.3 / TERMINATION ROOMS 2 HR, 713.13.4: 1 HOUR 3/4 HR "C" LABEL DOOR REFUSE ACCESS 1 HR, 713.13.3 / TERMINATION ROOMS 2 HR, 713.13.4: 1 HOUR 3/4 HR C DOOR

1950 PIEDMONT CIRCLE NE


FLOOR / CEILING CONSTRUCTION (PER 601): 2 HOUR - FLOOR / CEILING CONSTRUCTION (PER 601): 1 HOUR - FLOOR / CEILING CONSTRUCTION (PER 601): 1 HOUR

ATLANTA, GA 30324
ROOF CEILING CONSTRUCTION (PER 601): N/A HOUR - ROOF CEILING CONSTRUCTION (PER 601): 1 HOUR - ROOF CEILING CONSTRUCTION (PER 601): 1 HOUR
STRUCTURAL BEAMS, GIRDERS, TRUSSES, ARCHES (PER 601): 3 HOUR - STRUCTURAL BEAMS, GIRDERS, TRUSSES, ARCHES (PER 601): 1 HOUR - STRUCTURAL BEAMS, GIRDERS, TRUSSES, ARCHES (PER 601): 1 HOUR
STRUCTURAL COLUMNS (PER 601): 3 HOUR - STRUCTURAL COLUMNS (PER 601): 1 HOUR - STRUCTURAL COLUMNS (PER 601): 1 HOUR

STAIRS : STAIRS : STAIRS :


STAIR WIDTH (PER 1011.2 & 1005.3.1): MIN. REQUIRED 44" MIN. PROVIDED 48" STAIR WIDTH (PER 1011.2 & 1005.3.1): MIN. REQUIRED 44" MIN. PROVIDED 48" STAIR WIDTH (PER 1011.2 & 1005.3.1): MIN. REQUIRED 44" MIN. PROVIDED 48"
NUMBER OF FLOORS CONNECTED: 2 NUMBER OF FLOORS CONNECTED: BLDG-3000B:4 STORIES, BLDG 4000: 5 STORIES NUMBER OF FLOORS CONNECTED: BLDG-1000: 6 STORIES, BLDG-2000: 5 STORIES

ELEVATOR LOBBIES ELEVATOR LOBBIES ELEVATOR LOBBIES


REQUIRED (PER GA AMENDMENTS 713.14.2): N/A REQUIRED (PER GA AMENDMENTS 713.14.2): N/A REQUIRED (PER GA AMENDMENTS 713.14.2): YES, EACH ELEVATOR
FLOOR LOCATIONS: N/A FLOOR LOCATIONS: N/A FLOOR LOCATIONS: AT ELEVATORS 1 AND 2

FIRE PROTECTION SYSTEM FIRE PROTECTION SYSTEM FIRE PROTECTION SYSTEM


SPRINKLER SYSTEM PROVIDED (PER 903.3.1.1): NFPA 13 SPRINKLER SYSTEM PROVIDED (PER 903.3.1.1): NFPA 13 SPRINKLER SYSTEM PROVIDED (PER 903.3.1.1): NFPA 13
STANDPIPES REQUIRED (PER 905): YES - WET MANUAL AT STAIRWELLS STANDPIPES REQUIRED (PER 905): YES - WET MANUAL AT STAIRWELLS STANDPIPES REQUIRED (PER 905): YES - WET MANUAL AT STAIRWELLS
FIRE EXTINGUISHERS (PER 906): PROVIDED ALONG CORRIDOR @ 75'-0" MAXIMUM TRAVEL DISTANCE. FIRE EXTINGUISHERS (PER 906): PROVIDED ALONG CORRIDOR @ 75'-0" MAXIMUM TRAVEL DISTANCE FIRE EXTINGUISHERS (PER 906): PROVIDED ALONG CORRIDOR AT 75'-0" MAXIMUM TRAVEL DISTANCE

EXITS REQUIRED EXITS REQUIRED EXITS REQUIRED


BUILDING EXITS (PER 1022.1): PER FLOOR: 2 MIN WITHIN ALLOWED TRAVEL DISTANCE BUILDING EXITS (PER 1022.1): PER FLOOR: 2 MIN WITHIN ALLOWED TRAVEL DISTANCE BUILDING EXITS (PER 1022.1): PER FLOOR: 2 MINIMUM WITHIN ALLOWABLE TRAVEL DISTANCE
A DEVELOPMENT FOR:

HORIZONTAL EXITS (PER 1026): 2 HOUR HORIZONTAL EXITS (PER 1026): 2 HOUR HORIZONTAL EXITS (PER 1026): 2 HOURS; SEE PLANS FOR LOCATIONS
TRAVEL DISTANCE (PER 1017.2): 200' UNIT, 250' RES/ASS, 300' BUS ALLOWED REFER PLANS PROVIDED TRAVEL DISTANCE (PER 1017.2): 200' (UNIT), 250'-0" ALLOWED REFER PLANS PROVIDED TRAVEL DISTANCE (PER 1017.2): 200' (UNIT), 250'-0" ALLOWED SEE PLANS PROVIDED
DEAD END CORRIDOR (PER 1020.4 EXCEPTION 2): 50'-0" ALLOWED REFER PLANS PROVIDED DEAD END CORRIDOR (PER 1020.4 EXCEPTION 2): 50'-0" ALLOWED REFER PLANS PROVIDED DEAD END CORRIDOR (PER 1020.4 EXCEPTION 2): 50'-0" ALLOWED SEE PLANS PROVIDED
UNITS OF EGRESS (PER 1005.1): CORRIDOR WIDTH = .20 INCH PER OCCUPANT DOOR WIDTH = 36" UNITS OF EGRESS (PER 1005.1): CORRIDOR WIDTH = .20 INCH PER OCCUPANT DOOR WIDTH = 36" UNITS OF EGRESS (PER 1005.1): CORRIDOR WIDTH = .20 INCH PER OCCUPANT DOOR WIDTH = 36"
STAIR WIDTH = .30 INCH PER OCCUPANT STAIR WIDTH = .30 INCH PER OCCUPANT STAIR WIDTH = .30 INCH PER OCCUPANT

ROOF ACCESS ROOF ACCESS ROOF ACCESS ISSUE


DATE DESCRIPTION INCLUDED
ROOF ACCESS PROVIDED: - ROOF ACCESS PROVIDED: YES - NEAR ELEVATOR 3 ROOF ACCESS PROVIDED: YES - CORRIDOR NEXT TO STAIRS B 04.30.2021 SCHEMATIC DESIGN SET X
05.28.2021 LAND DISTURBANCE PERMIT SET X
07.02.2021 DESIGN DEVELOPMENT SET X
ATTIC VENTILATION ATTIC VENTILATION ATTIC VENTILATION 08.27.2021 FOUNDATION PERMIT SET
09.03.2021 60% CD PROGRESS SET X
10.18.2021 PERMIT SET / GMP X
ATTIC VENTILATION REQUIRED (PER 1202.3): NO ATTIC VENTILATION REQUIRED (PER 1202.3): NO ATTIC VENTILATION REQUIRED (PER 1202.3): NO 11.24.2021 ADDENDUM A1
12.22.2021 PERMIT REPRINT X
ATTIC VENTILATION TYPE: N/A ATTIC VENTILATION TYPE: N/A ATTIC VENTILATION TYPE: N/A 01.28.2022 PROGRESS SET X
08.10.2022 ISSUED FOR CONSTRUCTION

NOTES: NOTES: NOTES:


1. SEE SHEET CD-70 &71 FOR PARTITION TYPES & RATINGS 1. SEE SHEET CD-70 &71 FOR PARTITION TYPES & RATINGS 1. SEE SHEET CD-70 &71 FOR PARTITION TYPES & RATINGS
2. FEC = FIRE EXTINGUISHER CABINET 2. FEC = FIRE EXTINGUISHER CABINET 2. FEC = FIRE EXTINGUISHER CABINET REVISION
DATE DESCRIPTION REV
3. INTERSTITIAL SPACE AT ROOF CAVITY AND FLOOR/CEILING NOT TO BE SPRINKLERED IF COMPLETLY FILLED WITH INSULATION 3. INTERSTITIAL SPACE AT ROOF CAVITY AND FLOOR/CEILING NOT TO BE SPRINKLERED IF COMPLETLY FILLED WITH INSULATION 3. INTERSTITIAL SPACE AT ROOF CAVITY AND FLOOR/CEILING NOT TO BE SPRINKLERED IF COMPLETLY FILLED WITH INSULATION
4. ALL ELEVATORS ARE MIN 3500 LB - MEETING STRETCHER REQUIREMENTS. SEE ELEVATOR DETAILS FOR ADDITIONAL INFORMATION 4. ALL ELEVATORS ARE MIN 3500 LB - MEETING STRETCHER REQUIREMENTS. SEE ELEVATOR DETAILS FOR ADDITIONAL INFORMATION 4. ALL ELEVATORS ARE MIN 3500 LB - MEETING STRETCHER REQUIREMENTS. SEE ELEVATOR DETAILS FOR ADDITIONAL INFORMATION

SEAL:
C:\Users\aaragi\Documents\FF Intown_Residential_R20_aaragi.rvt

DISCLAIMER:
THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE
PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE
REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS
REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED
FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND
ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN
CONSENT OF DWELL DESIGN STUDIO.
SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL
DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES.

SHEET NAME:

C dwell design studio - ALL RIGHTS RESERVED


BUILDING
CODE DATA

IFC SET

JOB NUMBER: 2103801

DRAWN BY CHECKED BY
Author Checker
8/12/2022 6:20:52 PM

CD-01
ISSUED FOR CONSTRUCTION
BUILDING CODE DATA - PARKING DECK TYPE IIA
BUILDING OCCUPANCY CLASSIFICATION : OPEN PARKING GARAGE
AREA ALLOWED PER FLOOR : (PER TABLE 406.5.4) 50,000 SQ.FT.
SQ.FT. INCREASE ALLOWED BY AREA N/A
MODIFICATIONS (PER 506) :

1280 HIGHTOWER TRAIL


ATLANTA, GA 30350
BUILDING TYPE PARKING AREAS 5000 PHONE: 770.864.1035
Name Level Area dwelldesignstudio.com
BLDG - PARKING DECK LEVEL T1 261.77 SF
BLDG - PARKING DECK LEVEL 1 28871.55 SF
BLDG - PARKING DECK LEVEL 2 28871.55 SF
BLDG - PARKING DECK LEVEL 3 28871.55 SF
BLDG - PARKING DECK LEVEL 4 28871.55 SF
BLDG - PARKING DECK LEVEL 5 28871.55 SF
BLDG - PARKING DECK LEVEL 6 28871.55 SF
BLDG - PARKING DECK LEVEL 7 9168.74 SF

TYPE OF CONSTRUCTION : IIA


BUILDING HEIGHT ALLOWANCE (PER 406.5.4) : 10 TIERS
BUILDING HEIGHT PROVIDED : 7 TIERS | 79' - 5 1/4"

FIRE RATING : WALLS AND PARTITIONS OPENING PROTECTION


FIRE WALLS (PER 706.4): 2 HOUR 1 1/2 HR 'A' LABEL DOORS
FIRE BARRIERS (PER 707.3.10): 2 HOUR 1 1/2 HR

FAIRFIELD AT PIEDMONT
MIXED OCCUPANCY SEPARATION (PER 508.4): 2 HOUR 1 1/2 HR
INTERIOR BEARING WALLS (PER 601): 1 HOUR -
INTERIOR NON-BEARING WALLS (PER 601): 0 HOUR -
EXTERIOR NON-BEARING WALLS: > 30' SEP. / < 30' SEP. (PER 602): 0 / 1 HOUR -
EXTERIOR BEARING WALLS 1 HOUR -
CORRIDOR WALLS (PER 1018.1): 1 HOUR -

1950 PIEDMONT CIRCLE NE


ELEVATOR SHAFT WALLS (PER 713): 2 HOUR 1 1/2 HR B DOOR
REFUSE CHUTE SHAFT WALLS (PER 708.13.1): 2 HOUR 1 1/2 HR B DOOR

ATLANTA, GA 30324
REFUSE ACCESS AND TERMINATION ROOMS (PER 713.13.3 & 713.13.4): 2 HOUR 1 1/2 HR
FLOOR / CEILING CONSTRUCTION (PER 601): 1 HOUR -
ROOF CEILING CONSTRUCTION (PER 601): 1 HOUR -
STRUCTURAL BEAMS, GIRDERS, TRUSSES, ARCHES (PER 601): 0 HOUR -
STRUCTURAL COLUMNS (PER 601): 0 HOUR -

STAIRS :
STAIR WIDTH (PER 1009.3) MIN. REQUIRED MIN. REQUIRED 48"
NUMBER OF FLOORS CONNECTED 7 STORIES

ELEVATOR LOBBIES
REQUIRED (PER GA AMENDMENTS 713.14.2): NOT REQUIRED PER EXCEPTION 3
FLOOR LOCATIONS AT ELEVATOR 3, LEVELS 1 THROUGH 7

FIRE PROTECTION SYSTEM


SPRINKLER SYSTEM PROVIDED (PER 903.3.1.1) NO
STANDPIPES REQUIRED (PER 905.4) YES AT STAIRWELLS
FIRE EXTINGUISHERS (PER 906.3.1) PROVIDED @ 75' MAX TRAVEL DISTANCE A DEVELOPMENT FOR:

EXITS REQUIRED
BUILDING EXITS (PER 1006.3.2) PER FLOOR: 2 MIN WITHIN ALLOWED TRAVEL DISTANCE
HORIZONTAL EXITS (PER 1026) SEE PLANS FOR LOCATIONS
TRAVEL DISTANCE (PER 1017) 300'-0" ALLOWED SEE PLANS PROVIDED
DEAD END CORRIDOR (PER 1020.4) 50'-0" ALLOWED 0 PROVIDED
CORRIDOR WIDTH = .20 PER OCCUPANT ISSUE
DATE DESCRIPTION INCLUDED
UNITS OF EGRESS (PER 1005.3.1 & 1005.3.2)
04.30.2021 SCHEMATIC DESIGN SET
STAIR WIDTH = .30 PER OCCUPANT 05.28.2021 LAND DISTURBANCE PERMIT SET X
07.02.2021 DESIGN DEVELOPMENT SET X
08.27.2021 FOUNDATION PERMIT SET
NOTES: 09.03.2021 60% CD PROGRESS SET X
10.18.2021 PERMIT SET / GMP X
11.24.2021 ADDENDUM A1
12.22.2021 PERMIT REPRINT X
01.28.2022 PROGRESS SET X
08.10.2022 ISSUED FOR CONSTRUCTION

REVISION
DATE DESCRIPTION REV

SEAL:
C:\Users\aaragi\Documents\FF Intown_Residential_R20_aaragi.rvt

DISCLAIMER:
THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE
PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE
REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS
REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED
FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND
ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN
CONSENT OF DWELL DESIGN STUDIO.
SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL
DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES.

SHEET NAME:

C dwell design studio - ALL RIGHTS RESERVED


BUILDING
CODE DATA

IFC SET

JOB NUMBER: 2103801

DRAWN BY CHECKED BY
Author Checker
8/12/2022 6:20:57 PM

CD-02
ISSUED FOR CONSTRUCTION

You might also like