Modicon Libraries 2022 - General Purpose V2 for

Control Expert - Release Note

Table of Contents

1. Overview ............................................................................................................................... 2
2. Features ................................................................................................................................ 2
3. New Blocks ........................................................................................................................... 2
4. Impact of Template Update ................................................................................................... 3
5. Enhancements/Fixes ............................................................................................................. 3
6. Key points ............................................................................................................................. 4
7. Known Limitation ................................................................................................................... 4
8. Know Issues .......................................................................................................................... 4

Modicon Libraries 2022 - General Purpose V2 for Control Expert - Release Note Page 1 of 3
1. Overview

This document describes the features, some key points and known limitations of “ Modicon Libraries 2020 -
General Purpose V2 for Control Expert - Release Note”.

2. Features
The Control Expert components (function blocks, components, and libraries) provide the commonly required
functions facilitating the development of the control systems

The following are the list of Control Blocks:

Sl No DFB/EFB Family No of DFB / EFB


1 Process 89
2 Devices 37
3 Diagnosis 18
4 Communication 42
5 SignalConditioning (EFB) 6

3. New Control Blocks


DFB
Sr.No Name Version Description
1 ATV6xxx 0.13 ATV6xxx DFB Control
2 EIOSATS480 1.39 ATS480 DFB Control for Implicit Messaging
3 EIOSATV340 0.79 ATS340 DFB Control for Implicit Messaging
4 EIPATS480DATA 0.38 ATS480 Explicit data read DFB
5 EMEasergyP3 1.14 Easergy P3 on Modbus Ethernet
6 EMEasergyP5 1.24 Easergy P5 on Modbus Ethernet
7 EMESATS480DATA 0.24 ATS480 Explicit data read DFB
8 EMESATV340 2.87 ATV340 - Modbus Ethernet Messaging DFB Control
9 FLOWASSET05GP 0.04 Pumping asset block which can handle 5 pumping assets
10 ILCKOFFGP 0.03 Interlock conditions summary block
11 LOADCELLGP 0.04 PMESWT with EIP unconnected messaging DFB control
12 MOTORMNTGP 0.03 Motor maintenance
13 RALARMGP 0.01 ROC alarm
14 SCHEDULERGP 0.04 Scheduler Function block
15 SEQCTL1GP 0.01 Advanced sequential control
16 PIDADVCTLGP 0.09 PID advanced control
17 M340DiagGP 0.02 M340 Diagnostic
18 M580DiagGP 0.03 M580 Diagnostics
19 VALVEMNTGP 0.04 Valve maintenance

Modicon Libraries 2022 - General Purpose V2 for Control Expert - Release Note Page 2 of 3
4. Impact of Control Blocks Update
When you update Control blocks, systems in which these Control blocks are used are affected. To help you
assess the impact of a Control blocks update, impacts are grouped in categories. Each block belongs to an
impact category.

Impact Category Description

A Update of Control blocks may result in stop of Controller.


B Hardware/Communication mapping may be lost.
C Minor Change, Incremental deploy may be required.
D Update in Supervision Include project.
R Recommend updating Control blocks (Not Mandatory).

5. Enhancements/Fixes
DFB Impact
Sr.No Name Version Category Description
Failcode[0] fixed for showing correct
1 ATV6xx 0.22 C information
Failcode[0] fixed for showing correct
2 ATV9xx 0.16 C information
 Modbus identity added
 Reset logic modified to ensure reset
3 ATVEngine 1.83 C in single click from supervision
4 ATVPARAM 0.13 C Modified as part of ATVEngine
5 ModbusEthernetPort1M4 1.05 C
6 ModbusEthernetPort1M16 1.07 C MBEthWorkMemory DDT updated
7 AINPUTGP 0.02 C Constant option checked for Engineering DDT
8 FLOWCTLPATTERNGP 0.07 C Added new strategies and implemented
9 LDLGCTLGP 1.03 C IO Parameter DDT updated
10 MOTOR2GP 0.02 C IO Parameter DDT updated
11 MOTORGP 0.03 C IO Parameter DDT updated
12 MOTORVSGP 0.06 C IO Parameter DDT updated
13 MVALVEDGP 0.05 C IO Parameter DDT updated
14 MVALVEDLPGP 0.03 C IO Parameter DDT updated
15 MVALVEGP 0.06 C IO Parameter DDT updated
Configuration variable modified to support
16 PHASEGP 0.10 C OPC UA communication
Time, TI, TD datatype changed to Real to
17 PIDCTLGP 0.03 C support OPC UA communication
Time, TI, TD datatype changed to Real to
18 PIDTUNEGP 0.05 C support OPC UA communication
Time, TI, TD datatype changed to Real to
19 PIDMUXGP 0.03 C support OPC UA communication
20 PUMPINGASETSEQ1GP 0.03 C
Correction of logic for recalculation after
21 PUMPINGASETSEQGP 0.06 C adding new strategies

22 PUMPSETPATTERNGP 0.32 C
23 PWMCTLGP 0.32 C IO Parameter DDT updated
24 RATIOCTLGP 0.04 C IO Parameter DDT updated
25 VALVEGP 0.02 C IO Parameter DDT updated
Modicon Libraries 2022 - General Purpose V2 for Control Expert - Release Note Page 3 of 3
6. Key points
1. Help on type for the User created Control Expert DFBs are not supported.

7. Known Limitation
1. During M580 HSBY Switchover, freshness of the drive (ATV9xx/ATv6xx) is getting healthy after 30-
35sec in Implicit Communication. This issue occurs sporadically. If user is experiencing this observation,
User should call support and check on the necessary steps to resolve the issue quoting the following
support case number which is reported to Drives Team.
i. “PEP0331528R”
ii. “PEP0331529R”

8. Know Issues
No known issues