Anchor tensile resistance (EN1992-4- CL. 72.1.3) = 14 KN > Neg= 1088 KN Naas = Nana = 0+ Ae fuk = 168.8 KN Where = 085 reduction factor for cut theead A, = 245 mm? ——tonsio stress area fax = 800.0 MPa ~ minimum tensile strongth of the bolt ‘qe =1.50—~ safety factor for steo! ota 12 > 1A ee: © fyk = 540.0 MPa— minimum yield strength ofthe bot Concrete breakout resistance of anchor in tension (EN1992-4 Cl. 7.2.1.4) Te check is preformed for group of anchors that form common tension breakout cone: AY, A2, A3, Ad, AS, A6, AT, AB Nae = Me = 2616 AW < 13408 wy Nathe = MRie* 4 Wa Uren Wee Watw = 470.9 xN Where Nety = 1340.8 kN. — sum of tension forces of anchors with common conerate breakout cone area NB, = 201.1 kN ~ characteristic strength of a fastener, remote from the effects of adjacent fasteners or edges of the ‘conerate member + Mbge = hae FEMA, where © ky = 890 parameter accountng for anchor ype ard conerete corltion of = 250MPa~ concrete compressive strength © hey = min(Fems, max( 2, e+) = 273 mm-—depth of embedment, where: + ays = 500 mm ~anchor length embedded in concrete 10 mm = maximum distance from the anchor one of the tee closest edges + Spar = 495 mm-—maximum spacing between anchors Aan = 1750446 mn? ~ concrete breakout cone area for group of anchors ‘Aly = 672400 mn? ~ careraa breakout core aea fo single archer nt nuanced by gen + Ady = (B+ hep)? where: © ney = 273 mm depth of embedment = 0.99. — parameter related tothe cistibution of stresses in the conerete du tothe proximity of the fastener to an ledge of the concrete member: + Wan =O. 4 03+ po <1 where © © = 400 mm minimum distance from the anchor tothe edge © hey = 273 mm ~ depth of embedment ‘Yrew = 1.00 ~ parameter accounting forthe shell spaling: bea = 0.5 + et <1, where © hems = 500 mm anchor langth embedded in concrete Yecxv = 0.80 ~ modification factor for anchor groups loaded eccentially in tension: + Bean = eo + Pecy.w . where: © Yas — tine — 1.00-modieaton factor tal depends on eccentaty in xrecton © 2,3" = O mm tension load eccentricity in x-direction Pua’ = {Baw = 0.90 modification factor hat depends on eccentcty in yrection © ey, = 45 mm tension oad eccentric in y-direction © hey = 273 mm depth of embedment ‘ara = 1.00 parameter accounting forthe effect of @ compression force between the fixture and concrete this parameter equal to 1f¢< 1.5hg or the rato ofthe compressive fore (including the compression due to bending) tothe sum of tensile forces in anchors is smallr than 0.8 suuy = 2 > 1 whore = 85 mm — internal evr ar 0. hey = 273 mm=depth of embedment “Ae = 1.80 ~ safety factor for concrete Concrete pullout resistance (EN1992-4 Ci. 7.2.1.6) Naty = S@2 = 10089 KN = Npg= 1088 KN Nake = ka An > foe = 1816.1 KN Who ky =750 ~cosfcient for rackeduneracked conerste An = 9686 mm? area ofthe load-bearing head ofthe fastener + An sal, — $+ , where: © dy = 100 mm-length of the edge ofthe rectangle washer pate 2 d= 20mm dameter ofthe shank ofthe fastener for =25.0 MPa ~ concrete compressive strength Me — 1.80 ~ safety factor for concrete Concrete blowout resistance (EN1992-4 -Cl. 7.2.1.8) Voritcation of concrote blowout fair isnot required if the adge distance ¢s > 0.5 Per ‘Shear resistance (EN19924 -C17.22.3.1) Vege = W22= 784 KN & Vig 0.4 KN Vitis = kr -Viteg = 98.0 kN Where 4.00 coefficient for anchor steel ductity where 08, A<0.08 10, A> 0.08 © A= 0.12—bolt grade elongation at rupture Vie = 98.0KN the characterise shear strength + Vig = Be As faa whore ©. ks = 0.50~coefclont fr anchor resistance in shear oA, = 245 mm2—tensie sess area © fas = 800.0 MPa specified ultimate strength of anchor ste! ats = 1.25 ~ safely factor for steel Conerate pryout resistance (EN1992-4 Cl. 7.22.4) Tho chock ls preformed for group of anchors on common base plate Video = 6985 KN = Vigg= 0.0 kN Vitnep = Be Nae = 1088.7 kN Where ky = 2.00 factor taking into account fastener embedment depth Ninee = 522.3 kN ~ characteristic concrete cone strength fora single fastener or fastener in a group Me = 1.60 safety factor for concrete Interaction of tensile and shear forces in steel (EN 1992-4 Table 7.2) (it) + (Ga) = 088 « 10 Whee Neg = 108.8KN design tension force Naas = 111.1 KN fastener tensile strength Visu=0.1 KN design shear force Vga =784 kN. —fastener shear strength Interaction of tensile and shear forces in concrete (EN 1992-4 Table 7.2) CREED 4 FREY = 1160 > 4.0 Where: HEL the argost ubizaton value fr tension fire modes YEE tne largest utzon vate fr sea fue modes

You might also like