Dead Load

1. Floor Finish KN/m2 Ib/ft2


1. Cement plaster 10 mm thicness 0.23 4.80
2. Clay tiling, 13 mm thick 0.268 5.60
1.1 Ceiling Plaster(Bottom Roof plaster) KN/m2 Ib/ft2
1.Cement plaster 13 mm thick 0.287 6.00
2. Brick Wall kip/ft
1. Weight of the 5'' Wall 0.441
2. Weight of the 5'' Prapet Wall 0.165

Live Load
Occupancy or Use kN/m2 Ib/ft2
1. All other areas except stairs and balconies 2 41.78
2. Roofs used for promenade purposes 2.9 60.58
3. Stairs and exit ways 4.8 100.27
Earthquck Load
Wind Load
Load
Total (Ib/ft2) BNBC Referance BNBC 2016 similar with ACI-1999,UCB-94
page Table BNBC 2020 similar with ACI 318-08,
10.40
533 6.2.2 Seismic load: ASCE 7-05
Total (Ib/ft2) R.C.C Design: ACI 318-08
6.00 534 6.2.2 Steel Design: AISC 360-05
Total (kip/ft) 1KN/m2 = 20.89 Psf
0.44 532 6.2.1 1KN/m3 = 6.4 Psf = 101.937 kg/m3
0.17

oad Weight of the 5'' Wall=Unit Weight of Brick *Thicness of the


Wall * Height of the Wall excluding Beam
Total (Ib/ft2) BNBC Referance
41.78 538 6.2.3 Brick Unit Weight BNBC Referance
60.58 539 6.2.3 KN/m3 Pcf kg/m3 page
100.27 539 6.2.3 18.9 120.96 1926.61 532
Height of the wall=10'-Beam depth
Height of the wall=10'-(15''/12)

Wind Load
BNBC Referance
Searching for Name Section page table
Wind Speeds(Mph) 603 6.2.8
Exposur Type 2.4.6.3 554 6.2.20
Wind Co- Important Factor, I 604 6.2.9
efficient Tophographical Fector,Kzt
Gust Fector
Directional Fector Kd

BNBC Referance
Searching for Name Figur page table
Wind Windward Co, Cpw(0.8) 6.2.6 574
Pressure Co-
efficient Leeward Co ,Cpl 6.2.6 574
Earthquack Load
Design Base shear V = 2𝑍𝐼/3𝑅
𝐶𝑠𝑊
R=Respons reduction factor

BNBC Referance
Searching for Name Section page table Equatoin
ght of Brick *Thicness of the
Base Design Base shear 2.5.7.1 629 6.2.37
ll excluding Beam
shear,V Design Response Spectrum 2.5.4.3 614 6.2.34
BNBC Referance
Table
6.2.1 BNBC Referance
Searching for Name Section page table Equatoin

Seismic Force–Resisting
System Category. 624 6.2.19

Factors Its depends on Zone,


R
Occupency Category and 620 6.2.18
site class.
ω
Cd Seismic
Zone 618 6.2.14
I
Referance Occupency Category 483 6.1.1
Equatoin Site Class(SPT value) 612 6.2.13
Important Factor, I 619 6.2.17

N̅ =
(𝒅𝟏+𝒅𝟐+𝒅𝟑)/(𝒅𝟏/𝑵𝟏+𝒅𝟏/𝑵𝟏+
𝑵=𝑵𝒖𝒎𝒃𝒆𝒓 𝒐𝒇 𝐛𝐥𝐨𝐰
𝒅𝟏/𝑵𝟏) d = Thicness of layer

BNBC Referance
Searching for Name Section page table Equatoin
Ss 1618 6.2.39
S1 1618 6.C.1
Referance Seismic
Co- Long-period Trangition 619 6.2.16
Equatoin efficient period
Fa 1618 6.C.2
site class, F
Fv 1618 6.C.3

Seismic weight(W) dead load 1


(total weight of building and 2.5.7.3 631
25% of live losd) Live load 0.25

Difine messsource modify chack specified load patern


rthquack Load

A. BEARING WALL SYSTEMS


(no frame)
B.BUILDING FRAME SYSTEMS
(with
C. bracingRESISTING
MOMENT or shear wall)
FRAME SYSTEMS (no
shear wall)
D. DUAL SYSTEMS: SPECIAL MOMENT FRAMES CAPABLE OF RESISTING AT LEAST
25% OF PRESCRIBED SEISMIC FORCES (with bracing or shear wall)

E. DUAL SYSTEMS: INTERMEDIATE MOMENT FRAMES CAPABLE OF RESISTING AT


LEAST 25% OF PRESCRIBED SEISMIC FORCES (with bracing or shear wall)

𝑇=𝐶𝑡 〖 (ℎ𝑛) 〗 ^𝑚
BNBC Referance
Searching for Name Section page table Equatoin

The building period T (in


sec) may be approximated
by the following 630 6.2.38
Time period formula.
T
Concrete moment-resisting
frames 631 6.2.20