Professional Documents
Culture Documents
Datasheet-KIMO LiquidManometers-English
Datasheet-KIMO LiquidManometers-English
INCLINED LIQUID
COLUMN MANOMETERS
Pressure / Depression
KEY POINTS
The CP 25 inclined liquid column manometer, developed and manufactured by KIMO measures slight variations in pressure, depression or
differential pressure of air or gas.
It is specially designed for checking clogging of filters in painting booths.
●
Graduation scale via coloured zones for fast and easy reading
● Safety reservoir enabling momentaneous overshooting of the scale
●
Supplied with two 487 connectors and a bottle of AWS 10 liquid
85 mm
76 mm SNESITIVITY SCALE
for 1 mm CE
152 mm 15 mm 5 mm
from 0 to 5 mm CE : white
from 5 to 10 mm CE : green
from 10 to 15 mm CE : yellow
from 15 to 25 mm CE : red (Variations possible on request).
Ref. FTang – CP25 – 01/99 A - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Positioning Horizontal positioning via integrated spirit level and milled, nickel-plated brass adjusting screw,
vertical travel 12 mm
Manometric liquid AWS 10 red oil - density 0.87 at 15°C.
Reservoir capacity 20 ml
Connection Ø 5x8 mm semi-rigid crystal tube, on Ø 6.2 mm ribbed, nickel-plated brass connectors,
1/8 gas thread.
Wall-mounted With or without white PVC support
MOUNTING
1. Mount on a wall or a vertical partition wall with two maximum Ø 5 x 25 mm screws (supplied).
2. Set horizontality using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. Connect the manometer with the Ø 5 X 8 mm crystal tube to the pressure or depression source to be checked.
NOTES :
For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)
MAINTENANCE :
The CP 25 manometer requires no special maintenance other than simply changing the reading liquid once a year.
Pression / Dépression
KEY POINTS
The GF range of vertical liquid column manometers, developed and manufactured by KIMO,
are mainly for checking pressures in gas networks within measurement ranges which vary
according to the type of manometric liquid used : VF 1 or MERCURY.
(See table below)
MEASURING RANGE
Ref. FTang – GF – 15/11/12 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Wall mounting 2 screws Ø 5 X 25 mm
DIMENSIONS
MOUNTING
1. Mount the manometer on a wall or partition wall with two maximum Ø 5 x 25 mm screws. a
2. Unscrew the left-hand connector and slowly pour the manometric liquid to zero point on
the graduation
3. Remount the connector without overtightening.
4. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression
source to be checked.
Note :
For a pressure measurement.............................. Connect the crystal tube to one of the two connectors
For a depression measurement.......................... Connect the crystal tube to one of the two connectors.
c
b
Pressure / Depression
KEY POINTS
MEASURING RANGE
Ref. FTang – HP – 01/99 A - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Reservoir capacity 20 ml
Connection Ø 5x8 mm semi-rigid crystal tube, on Ø 6.2 mm ribbed, nickel-plated brass connectors, 1/8
gas thread.
Wall-mounted With or without white PVC support.
DIMENSIONS
a
Reference HP 5 HP 10 HP 15
b
a 184 mm 234 mm 234 mm
b 116 mm 166 mm 166 mm
f c
c 80 mm 80 mm 80 mm
d 30 mm 30 mm 30 mm
e 180 mm 230 mm 230 mm
e f 71 mm 71 mm 71 mm
d Weight 340 g 430 g 430 g
MOUNTING
1. Mount on a wall or a vertical partition wall with two maximum Ø 5 x 25 mm screws (supplied).
2. Set horizontality using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. onnect the manometer with the Ø 5 X 8 mm crystal tube to the pressure or depression source to be checked.
NOTES :
For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)
MAINTENANCE :
HP manometers require no special maintenance other than simply changing the reading liquid once a year.
KEY POINTS
The KM vertical liquid column portable manometer, developed and manufactured by KIMO,
measures low pressures in gas networks.
● Easy to carry.
●
"U"- shaped column for pressure and depression measurement.
● Direct read-off by moving the gratuated slide strip.
● Safety valves actuation for momentaneous overshooting of the scale.
●
Fitted with valve connectors and mounting hook.
● Supplied with connection sleeves, a bottle of VOLT 1S liquid and carrying case.
MEASURING RANGE
DIMENSIONS
KM 45 306 X 50 X 20 mm 550 g
Ref. FTang – KM –20/10/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
MOUNTING
1. Dismount one of the 2 connectors using a no.12 spanner and slacken the milled head of
the other connector by one turn.
2. Check beforehand that the slide strip is at its lowest level.
3. Pour the liquid in the column using the spout.
4. Do not overfill. Never go beyond the NL line at the middle of the slide strip.
5. Remount the connector and screw the milled head of the other connector back down.
OPERATION
IMPORTANT :
•
Only VOLT1S liquid will ensure precise measurement (slide scale graduation
corresponding to the density of this liquid).
•
Maximum static pressure : 8 bars
KEY POINTS
MEASURING RANGE
Ref. FTang – KX – 05/08 B - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
vertical travel 12 mm.
Manometric liquid AWS 10 red oil, density 0.87 at 15°C
Reservoir capacity 20 ml
Connection Ø 5x8 mm semi-rigit crystal tube, on Ø 6.2 mm ribbed, nickel-plated brass connectors, 1/8 gas
thread.
Wall-mounted With or without white PVC support.
DIMENSIONS
a
Reference KX 205 KX404
b
a 178 mm 219 mm
b 110 mm 151 mm c
c 117 mm 154 mm f
d 25 mm 25 mm
e 174 mm 215 mm
f 109 mm 129 mm
e
weight 420 g 660 g d
MOUNTING
1. Mount the manometer on a wall or a vertical partition wall with two maximum Ø 5 x 25 mm screws.
2. Set horizontality by using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression source to be checked.
NOTE :
For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)
MAINTENANCE :
KX manometers require no special maintenance other than simply changing the reading liquid once a year.
Pressure / Depression
KEY POINTS
The LU range of vertical liquid column manometers, developed and manufactured by KIMO,
are mainly for measuring variations of pressure, depression or differential pressure of air or
gas within measurement ranges which vary according to the type of manometric liquid used :
AWS 10, VOLT 1S or MERCURY.
(See table below)
MEASURING RANGE
Ref. FTang – LU – 17/08/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Wall mounting With or without white PVC support.
ENCOMBREMENT
12,43cm
b
MOUNTING e
1. Mount the manometer on a wall or partition wall with two maximum Ø 5 screws.
2. Unscrew the left-hand connector and slowly pour the manometric liquid to zero point on the
graduation
3. Remount the connector without overtightening.
4. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression source to
be checked.
REMARQUES : d
c
For a pressure measurement..............................Connect the crystal tube to one of the two connectors
For a depression measurement..........................Connect the crystal tube to one of the two connectors.
For a differential pressure measurement...........Connect both tubes to both connectors
Pressure / Depression
KEY POINTS
●
Zero adjustement by moving the slide strip
● Safety reservoir enabling momentaneous overshooting of the scale
● Integrated spirit level for adjusting horizontality
● Supplied with a white PVC support, two screws and two rawplugs, two 487 connectors and a bottle of AWS 10 liquid
MEASURING RANGE
Ref. FTang – MG – 17/08/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Reservoir capacity 20 ml
Connection Ø 5 X 8 mm semi-rigid crystal tube, on Ø 6,2 mm ribbed, nickel-plated brass connectors, 1/8
gas thread
Wall-mounted With or without white PVC support
DIMENSIONS
a
Ø 6 mm
Cylindrical 1/8 gas connector
Ø 6.2 mm ribbing
b
c
f
e
d
Reference MG 20 MG 50 MG 80
a 196 mm 178 mm 219 mm
b 128 mm 110 mm 151 mm
c 80 mm 117 mm 154 mm
d 25 mm 25 mm 25 mm
e 192 mm 174 mm 215 mm
f 55 mm 109 mm 129 mm
Weight 320 g 420 g 660 g
MOUNTING
1. Mount on a wall or a vertical partition wall with two maximum Ø 5 x 25 mm screws (supplied).
2. Set horizontality using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. Connect the manometer with the Ø 5 X 8 mm crystal tube to the pressure or depression source to be checked.
NOTE :
For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)
MAINTENANCE :
MG manometers require no special maintenance other than simply changing the reading liquid once a year.
KEY POINTS
●
Easy to carry
● Safety reservoir enabling momentaneous overshooting of the scale
● Zero adjustment by moving the slide strip
● Integrated spirit level for adjusting horizontality.
● Equipped with valve connectors, magnetic fixations, support with base plate
●
Can be used for measuring speeds with Pitot tube.
● Supplied with connecting sleeves, bottle of VOLT 1 S liquid and travelling case.
MEASURING RANGE
Sensitivity scale
Reference Measuring range (mm CE) Résolution
For 1 mm CE
MT 40 0 – 40 4 mm 1 mm CE
Ref. FTang – MT – 17/08/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Reservoir capacity 20 ml
Connection on valve connectors in nickel-plated brass Ø 6.2 mm neoprene tubes with connecting sleeves.
DIMENSIONS
a
Cylindrical 1/8 gas connector
Ø 6.2 mm ribbing
c e
d
b
Reference a b c d e Weight
MT 40 193 mm 208 mm 93 mm 37 mm 80 mm 800 g
MOUNTING
1. Place the manometer on a horizontal surface or a vertical partition wall by using the magnetic fixations.
2. Set horizontality by using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slacken the milled wheel on the other connecter by one turn.
4. Slowly pour the manometric liquid to zero point on the graduation.
5. Remount the connector without overtightening.
6.Connect the manometer with the tube provided to the pressure or depression source to be checked.
NOTE :
For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)
MAINTENANCE :
MT40 manometer requires no special maintenance other than simply changing the reading liquid once a year.
Pressure / Depression
KEY POINTS
The TJ range of vertical liquid column manometers, developed and manufactured by KIMO,
are mainly for measuring variations of pressure, depression or differential pressure of air or
gas within measurement ranges which vary according to the type of manometric liquid used :
AWS 10, VOLT 1S or MERCURY.
(See table below)
●
"J"- shaped column for direct measuring.
● Zero adjustment by moving the slide strip.
● For fixed use regardless of the manometric liquid used.
● For portable use with the TJ model using VOLT 1S liquid.
●Supplied with a white PVC support, 2 screws and 2 rawlplugs, two 487 connectors
and a bottle of liquid.
MEASURING RANGE
Ref. FTang – TJ – 17/08/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
thread.
Wall-mounted With or without white PVC support.
DIMENSIONS
a
Cylindrical 1/8 gas
REF. TJ 100 TJ 150 TJ 300 TJ 600 TJ 1000
connectors.
a 57 mm 57 mm 57 mm 57 mm 57 mm
b 185 mm 243 mm 430 mm 777 mm 1239 mm
c 25 mm 25 mm 25 mm 25 mm 25 mm
d 52 mm 52 mm 52 mm 52 mm 52 mm Ø 6 mm
e 147 mm 205 mm 392 mm 739 mm 1201 mm
Distance between
tubes 171 mm 229 mm 416 mm 763 mm 1225 mm
Weight 290 g 310 g 450 g 790 g 1280 g
b
e
MOUNTING
1. Mount the manometer on a wall or partition wall with two maximum Ø 5 screws.
2. Unscrew one of the two connectors and slowly pour the manometric liquid to zero point on
the graduation.
3. Remount the connector without overtightening
4. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression
source to be checked.
NOTE :
For a pressure measurement..................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..............Connect the crystal tube to the left-hand connector (-)
For a differential pressure......................Connect the highest pressure to the right-hand connector(+)
and the lowest pressure to the left hand connector (-)
d c
Pression / Dépression
KEY POINTS
●
Scale with centered zero
● Possibility for measuring positive and negative pressures
● High measurement sensitivity
●
Very low pressure ranges
● Zero adjusting by moving the slide strip
●
Integrated spirit level for adjusting horizontality
● Supplied with a white PVC support, 2 screws and 2 rawlplugs, two 487 connectors and a bottle of AWS 10 liquid.
MEASURING RANGE
Ref. FTang – TX – 02/99 A - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Reservoir capacity 20 ml
Connection Connection : Ø 5x8 mm semi-rigid crystal tube, on Ø 6.2 mm ribbed, nickel-plated brass
connectors, 1/8 gas thread
Wall-mounted With or without white PVC support.
DIMENSIONS
a
Référence TX 25 TX 50 TX 75
b
a 184 mm 234 mm 234 mm
b 116 mm 166 mm 166 mm
c
c 80 mm 80 mm 80 mm
f d 30 mm 30 mm 30 mm
e 180 mm 230 mm 230 mm
f 71 mm 71 mm 71 mm
e poids 340 g 430 g 430 g
d
MOUNTING
1. Mount the manometer on a wall or a vertical partition wall with two maximum Ø 5 x 25 mm screws.
2. Set horizontality by using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression source to be checked.
NOTE :
For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)
MAINTENANCE :
TX manometers require no special maintenance other than simply changing the reading liquid once a year.
Pressure / Depression
KEY POINTS
●
Horizontale V-shaped liquid column.
● Dual measuring range
●
Different sensitivity on the two measuring ranges
● Zero adjustment via float
● Compact dimensions
●
Integrated spirit level for adjusting horizontality
●
Supplied with a white PVC support, 2 screws and 2 rawlplugs, two 487 connectors and a bottle of AWS 10 liquid.
MEASURING RANGE
Ref. FTang – VH – 17/08/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Reservoir capacity 20 ml
Connection Ø 5x8 mm semi-rigid crystal tube, on Ø 6.2 mm ribbed, nickel-plated brass connectors,
1/8 gas thread.
Wall-mount With or without white PVC support.
DIMENSIONS
a
Ø 6 mm
b Reference VH 50
Cylindrical 1/8 gas a 188 mm
connector
c b 120 mm
4cm
Ø 6.2 mm ribbing
3.68cm
f c 112 mm
d 25 mm
e 182 mm
f 101 mm
6.88cm
e Weight 380 g
d
MOUNTING
1. Mount the manometer on a wall or a vertical partition wall with two maximum Ø 5 screws.
2. Set horizontality by using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression source to be checked.
NOTE :
For a pressure measurement.............................. Connect the crystal tube to the right-hand connector (+)
For a depression measurement.......................... Connect the crystal tube to the left-hand connector (-)
For a differential pressure.................................. Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)
MAINTENANCE :
VH manometers require no special maintenance other than simply changing the reading liquid once a year.
TUBES
Ref. TS 4 X 7
Ref. TC 5 X 8
Clear tube Ø 5 x 8, for permanent installation (m/l or 25 m).
MANOMETER LIQUIDS
Ref. AWS 10
Density = 0,87. Bottles of : 20 ml, 30 ml,
125 ml, 250 ml, 500 ml, 1000 ml.
Ref. VOLT 1S
Density = 1,86. Bottles of : 10 ml, 20 ml, 30
ml, 125 ml.
Ref. HG
Density = 13,545. Bottles of :
10 ml, 20 ml, 30 ml, 125 ml.
Ref. VF1
Density = 1. Bottles of : 20 ml, 30 ml, 125
ml, 250 ml, 500 ml, 1000 ml.
PRESSURE CONNECTIONS :
Ref. 482
Ref. DP 339 Simple conection with rear nut, M5
Ref. KR 483 Connection for double-shell wall threading, length 15 mm. Drilling diameter :
Connection kit with 2 quick connections n° maximum thickness : 80 mm. Drilling 5 mm.
483 and 2 m of clear tube. diameter : 6 mm.
Ref. PC 482
Ref. 483 Through-connection for partitions standard
Ref. DP 447
Quick-connection for wall without rear lengths 35 to 190 mm.
Connection for double-shell wall, maximum
access. Other lengths on request.
thickness : 30 mm.
Drilling diameter : 10 mm. Drilling diameter :11 mm.
Drilling diameter : 6 mm.
DigiParts GmbH www.digiparts.ch info@digiparts.ch
MANOMETERS CONNECTIONS :
Ref. 509
Chromed brass safety connection,
Ref. FTang – Accessoires – 02/05 B - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
eliminating overspill on manometer using
AWS 10 and VOLT 1S. Ref. 484
Thread : 1/8 gas. Simple connection in nylon for TJ and
LU mercury manometers.
Thread : 1/8 gas.
JUNCTIONS
Ref. J.D.C
Straight connection for Ø 5 x 8 tube.
Ref. J.T.C Ref. J.Y.C
T-connection for Ø 5 x 8 tube. Y-connection for Ø 5 x 8 tube.
ACCESSORIES
Ref. 648-FM
Ref. 494 Ref. FM-KS.10
Safety reservoir, with magnetic fixings for
Pressure tube, length 1 m for MT and KM Set of 2 magnetic fixings.
mercury manometers.
manometers. With moulded ends.
Ref. 648-PF
Ref. GPN 900 Ref. ALTU.
Safety reservoir, permanent fixing for
Plug -8,5 A for all Ø 6,2 mm connections. Altunet cleaning product, 500 ml bottle..
mercury manometers.
10 units bag.