INCLINED LIQUID
COLUMN MANOMETERS
Pressure / Depression

KEY POINTS

The CP 25 inclined liquid column manometer, developed and manufactured by KIMO measures slight variations in pressure, depression or
differential pressure of air or gas.
It is specially designed for checking clogging of filters in painting booths.


Graduation scale via coloured zones for fast and easy reading
● Safety reservoir enabling momentaneous overshooting of the scale

Supplied with two 487 connectors and a bottle of AWS 10 liquid

DIMENSIONS MEASURING RANGE

Cylindrical 1/8 gas connector


Ø 6.2 mm ribbing
Ø 5 mm 0 – 25 mm CE

85 mm
76 mm SNESITIVITY SCALE
for 1 mm CE

152 mm 15 mm 5 mm

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TECHNICAL FEATURES

Recommended range of use From +5 to +30°C


Possible range of use From -30 to +60°C
Maximum static pressure 6 bars
Manometer body Transparent 15 mm thick Altuglas.
Liquid column Entirely bored in the solid block, Ø 4 mm.
Graduation Directly silk-screened onto the rear face with different colour zones :

from 0 to 5 mm CE : white
from 5 to 10 mm CE : green
from 10 to 15 mm CE : yellow
from 15 to 25 mm CE : red (Variations possible on request).

Ref. FTang – CP25 – 01/99 A - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Positioning Horizontal positioning via integrated spirit level and milled, nickel-plated brass adjusting screw,
vertical travel 12 mm
Manometric liquid AWS 10 red oil - density 0.87 at 15°C.
Reservoir capacity 20 ml
Connection Ø 5x8 mm semi-rigid crystal tube, on Ø 6.2 mm ribbed, nickel-plated brass connectors,
1/8 gas thread.
Wall-mounted With or without white PVC support

MOUNTING

1. Mount on a wall or a vertical partition wall with two maximum Ø 5 x 25 mm screws (supplied).
2. Set horizontality using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. Connect the manometer with the Ø 5 X 8 mm crystal tube to the pressure or depression source to be checked.

NOTES :
For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)

MAINTENANCE :
The CP 25 manometer requires no special maintenance other than simply changing the reading liquid once a year.

DigiParts GmbH www.digiparts.ch info@digiparts.ch


GF series
VERTICAL LIQUID
COLUMN MANOMETERS

Pression / Dépression

KEY POINTS

The GF range of vertical liquid column manometers, developed and manufactured by KIMO,
are mainly for checking pressures in gas networks within measurement ranges which vary
according to the type of manometric liquid used : VF 1 or MERCURY.
(See table below)

● ''U''-shaped column for measuring consecutively positive and negative pressures



Measurement by addition of values read on each column
● For fixed and portable use
● Zero adjustment by moving the slide strip

Possibility of resisting static pressures over 10 bars
● Altuglas column sunk into the solid block

Comes with bottle of liquid, 2 screws and rawplugs

MEASURING RANGE

Measuring range Resolution


Reference
mm CE mbar mm CE mbar
GF 500 250 – 0 – 250 25 – 0 – 25
VF1 LIQUID GF 1000 500 – 0 – 500 50 – 0 – 50
1 0,5

Measuring range Resolution


Reference
mm HG mbar mm HG mbar
GF 68 250 – 0 – 250 340 – 0 – 340
MERCURY 1 5
GF 134 500 – 0 – 500 670 – 0 – 670

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TECHNICAL FEATURES

Recommended range of use From +5 to +30°C


Possible range of use From -30 to +60°C
Maximum static pressure 14 bars
Manometer body 20 mm thick PVC
Liquid column Tube Ø 4 X 10 mm in altuglas for mercury
Tube Ø 6 X 10 mm for VF1
Graduated slide strip Transparent altiglas. Cross-section 54 X 3 mm
Zero adjustment By moving the graduated slide strip, travel 20 mm.
Fixed via milled, nickel-plated brass screw
Manometric liquid VF1 liquid, density 13,545 or mercury, density 1
Connection Ø 5x8 mm semi-rigid crystal tube on Ø 6.2 Delrin ribbed connectors with M 7x100 thread.

Ref. FTang – GF – 15/11/12 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Wall mounting 2 screws Ø 5 X 25 mm

DIMENSIONS

Ref. GF 500 GF 1000 GF 68 GF 134

a 607 mm 1107 mm 607 mm 1107 mm


b 70 mm 70 mm 70 mm 70 mm
c 25 mm 25 mm 25 mm 25 mm
Distance between
tubes 571 mm 1071 mm 571 mm 1071 mm
Weight 540 g 980 g 800 g 1450 g

MOUNTING

1. Mount the manometer on a wall or partition wall with two maximum Ø 5 x 25 mm screws. a
2. Unscrew the left-hand connector and slowly pour the manometric liquid to zero point on
the graduation
3. Remount the connector without overtightening.
4. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression
source to be checked.

Note :
For a pressure measurement.............................. Connect the crystal tube to one of the two connectors
For a depression measurement.......................... Connect the crystal tube to one of the two connectors.

c
b

DigiParts GmbH www.digiparts.ch info@digiparts.ch


HP series
INCLINED LIQUID
COLUMN MANOMETERS

Pressure / Depression

The HP range of inclined liquid column


manometers, developed and manufactured by
KIMO, measure slight variations in pressure,
depression or differential pressure of air or gas.
They are particularly recommended for
measuring overpressures in clean rooms,
operating blocks, laboratories, aseptic rooms,
laminar flows....

KEY POINTS

● High measurement sensitivity


● Very low pressure ranges

Zero adjustment by moving the slide strip.
● Integrated spirit level for adjusting horizontality.
● Supplied with a white PVC support, 2 screws and 2 rawlplugs, two 487 connectorsand a bottle of AWS 10 liquid.

MEASURING RANGE

Measuring range Sensitivity scale


Reference Resolution
mm CE Pascal for 1 mm CE or 10 PA
HP 5 0–5 0 – 50 20 mm 0,1 mm CE or 1 Pa
HP 10 0 – 10 0 – 100 15 mm 0,1 mm CE or 1 Pa
HP 15 0 – 15 0 – 150 10 mm 0,1 mm CE or 1 Pa

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TECHNICAL FEATURES

Recommended range of use From +5 to +30°C


Possible range of use From -30 to +60°C
Maximum static pressure 6 bars
Manometer body Transparent 20 mm thick Altuglas.
Liquid column Entirely bored in the solid block, Ø 4 mm.
Graduated slide strip Transparent Altuglas. Cross-section 20 x 2 mm.
Zero adjustment By moving the graduated slide strip, travel 12 mm
Fixed in place via milled, nickel-plated brass screw.
Positioning Horizontal positioning via integrated spirit level and milled, nickel-plated brass adjusting screw,
vertical travel 12 mm.
Manometric liquid AWS 10 red oil, density 0.87 at 15°C.

Ref. FTang – HP – 01/99 A - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Reservoir capacity 20 ml
Connection Ø 5x8 mm semi-rigid crystal tube, on Ø 6.2 mm ribbed, nickel-plated brass connectors, 1/8
gas thread.
Wall-mounted With or without white PVC support.

DIMENSIONS

a
Reference HP 5 HP 10 HP 15
b
a 184 mm 234 mm 234 mm
b 116 mm 166 mm 166 mm
f c
c 80 mm 80 mm 80 mm
d 30 mm 30 mm 30 mm
e 180 mm 230 mm 230 mm
e f 71 mm 71 mm 71 mm
d Weight 340 g 430 g 430 g

MOUNTING

1. Mount on a wall or a vertical partition wall with two maximum Ø 5 x 25 mm screws (supplied).
2. Set horizontality using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. onnect the manometer with the Ø 5 X 8 mm crystal tube to the pressure or depression source to be checked.

NOTES :
For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)

MAINTENANCE :
HP manometers require no special maintenance other than simply changing the reading liquid once a year.

DigiParts GmbH www.digiparts.ch info@digiparts.ch


PORTABLE MANOMETERS
WITH VERTICAL LIQUID COLUMN
KM serie
Pressure / Depression

KEY POINTS

The KM vertical liquid column portable manometer, developed and manufactured by KIMO,
measures low pressures in gas networks.

● Easy to carry.

"U"- shaped column for pressure and depression measurement.
● Direct read-off by moving the gratuated slide strip.
● Safety valves actuation for momentaneous overshooting of the scale.

Fitted with valve connectors and mounting hook.
● Supplied with connection sleeves, a bottle of VOLT 1S liquid and carrying case.

MEASURING RANGE

Reference Measuring range Resolution

KM 45 0 – 45 mbar 0.2 mbar

DIMENSIONS

Reference Dimensions (height. x width x thickness) Weight (with accessories)

KM 45 306 X 50 X 20 mm 550 g

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TECHNICAL FEATURES

Recommended range of use From +5 to +30°C


Possible range of use From -30 to +60°C
Pression statique maximum 8 bars
Manometer body 15 mm thick transparent Altuglas.
Liquid column Ø 4 mm bored into the solid block.
Graduated slide strip Altuglas transparent
Zero adjustment By moving the gratuated slide strip
Fixed in place via milled, nickel-plated brass screw.
Manometric liquid VOLT 1S, density 1.86 at 20°C.
Connection On Ø 6.2 nickel-plated brass valve connectors, with 1m long neoprene tube fitted with
dedicated end-pieces for gas equipment.

Ref. FTang – KM –20/10/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
MOUNTING

1. Dismount one of the 2 connectors using a no.12 spanner and slacken the milled head of
the other connector by one turn.
2. Check beforehand that the slide strip is at its lowest level.
3. Pour the liquid in the column using the spout.
4. Do not overfill. Never go beyond the NL line at the middle of the slide strip.
5. Remount the connector and screw the milled head of the other connector back down.

OPERATION

1. Hang up the manometer vertically by the mounting hook or hold manually.


2. Open to the air by slackening the milled heads of the 2 valves (one turn is sufficient).
3. Push one of the ends of the connecting tube firmly onto the right-hand valve. Push the other end of the tube onto the pressure point of the
pipeline or the instrument which has to be checked.
4. The liquid, under gas pressure, decreases in the right column and rises in the left one. If the gas flow occurs too hard and plays the safety
valve, repeat the operation by pinching the connecting tube more or less strongly to admit the gas more slowly (if the safety valve is working again, it
is because the pressure control exceeds the measuring range of the manomters)
5. When the liquid has settled, slide the graduated strip so as to bring the zero mark opposite the right-hand tube's liquid level (lowest level).
6. The graduation corresponding to the height of the liquid in the left-hand tube indicates the exact gas pressure.
7. Close off the 2 valves securely after operation

IMPORTANT :

Only VOLT1S liquid will ensure precise measurement (slide scale graduation
corresponding to the density of this liquid).

Maximum static pressure : 8 bars

DigiParts GmbH www.digiparts.ch info@digiparts.ch


KX series
INCLINED LIQUID
COLUMN MANOMETERS
Pressure / Depression

The KX range of inclined liquid column


manometers, developed and manufactured by
KIMO, measure slight variations in pressure,
depression or differential pressure of air or gas.
They are for use in the following applications :
treatment of air, ventilation, air conditioning,
heating, dust elimination...

KEY POINTS

● Scale with centered zero.


● Possibility for measuring positive and negative pressures.

Zero adjusting by moving the slide strip.
● Integrated spirit level for adjusting horizontality
● Supplied with a white PVC support, 2 screws and 2 rawlplugs, two 487 connectors and a bottle of AWS 10 liquid.

MEASURING RANGE

Measuring range* Sensitivity scale


Reference Resolution
mm CE Pascal For 1 mm CE or 10 PA
KX 205 25 – 0 – 25 250 – 0 – 250 3 mm 1 mm CE or 10 Pa
KX 404 40 – 0 – 40 400 – 0 – 400 2.5 mm 1 mm CE or 10 Pa

*Also exists in DaPa..

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TECHNICAL FEATURES

Recommended range of use From +5 to +30°C


Température d'utilisation possible From -30 to +60°C
Maximum static pressure 6 bars
Manometer body Transparent 15 mm thick Altuglas.
Liquid column entirely bored in the solid block, Ø 4mm.
Graduated slide strip Transparent Altuglas. Cross-section 20 x 2 mm.
Zero adjustment By moving the graduated slide strip, travel 12 mm.
Fixed in place via milled, nickel-plated brass screw.
Positioning Horizontal positioning via integrated spirit level and milled, nickel-plated brass adjusting screw,

Ref. FTang – KX – 05/08 B - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
vertical travel 12 mm.
Manometric liquid AWS 10 red oil, density 0.87 at 15°C
Reservoir capacity 20 ml
Connection Ø 5x8 mm semi-rigit crystal tube, on Ø 6.2 mm ribbed, nickel-plated brass connectors, 1/8 gas
thread.
Wall-mounted With or without white PVC support.

DIMENSIONS

a
Reference KX 205 KX404
b

a 178 mm 219 mm
b 110 mm 151 mm c
c 117 mm 154 mm f
d 25 mm 25 mm
e 174 mm 215 mm
f 109 mm 129 mm
e
weight 420 g 660 g d

MOUNTING

1. Mount the manometer on a wall or a vertical partition wall with two maximum Ø 5 x 25 mm screws.
2. Set horizontality by using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression source to be checked.

NOTE :

For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)

MAINTENANCE :
KX manometers require no special maintenance other than simply changing the reading liquid once a year.

DigiParts GmbH www.digiparts.ch info@digiparts.ch


LU series
VERTICAL LIQUID
COLUMN MANOMETERS

Pressure / Depression

KEY POINTS

The LU range of vertical liquid column manometers, developed and manufactured by KIMO,
are mainly for measuring variations of pressure, depression or differential pressure of air or
gas within measurement ranges which vary according to the type of manometric liquid used :
AWS 10, VOLT 1S or MERCURY.
(See table below)

● ''U''-shaped column for measuring consecutively positive and negative pressures


● Measurement by addition of values read on each column

Zero adjustment by moving the slide strip
● For fixed use regardless of the manometric liquid used
● For portable use with the LU model using VOLT 1S liquid
●Supplied with a white PVC support, 2 screws and 2 rawlplugs, two 487 connectors
and bottle of liquid

MEASURING RANGE

LU 100 LU 200 LU 400


Measuring mm CE 50 – 0 – 50 100 – 0 – 100 200 – 0 – 200
Liquide range mbar 5–0–5 10 – 0 – 10 20 – 0 – 20
AWS 10
Resolution : 1 mm CE or 0.5 mbar
Measuring mm CE 110 – 0 – 110 220 – 0 – 220 430 – 0 – 430
Liquide range mbar 11 – 0 – 11 22 – 0 – 22 43 – 0 – 43
VOLT 1S
Résolution : 5 mm CE or 1 mbar
Measuring mm HG 50 – 0 – 50 120 – 0 – 120 240 – 0 – 240
Mercure range mbar 80 – 0 – 80 160 – 0 – 160 310 – 0 – 310
Resolution : 1 mm HG or 10 mbar

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TECHNICAL FEATURES

Recommended range of use From +5 to +30°C


Possible range of use From -30 to +60°C
Maximum static pressure 6 bars
Manometer body Transparent Altuglas of 15 mm thick
Liquid column Ø 4 mm tube in extruded Altuglas.
Graduated slide strip Altuglas transparent. Section 40 X 2 mm
Zero adjustment By moving the graduated slide strip, travel 10 mm.
Fixed via milled, nickel-plated brass screw
Manometric liquid AWS 10 liquid, density 0.86, VOLT 1S liquid, density 1.86 or mercury, density 13.545
Connection Ø 5x8 mm semi-rigid crystal tube on Ø 6.2 nickel-plated brass ribbed connectors (for
manometers using AWS 10 or VOLT 1S liquid) or in Delrin (for mercury manometer), 1/8 gas
thread

Ref. FTang – LU – 17/08/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Wall mounting With or without white PVC support.

ENCOMBREMENT

REF. LU 100 LU 200 LU 400


a
a 57 mm 57 mm 57 mm
b 207 mm 324 mm 558 mm
c 25 mm 25 mm 25 mm
d 50 mm 50 mm 50 mm
e 169 mm 286 mm 520 mm
Distance between
tubes 193 mm 310 mm 544 mm
Weight 260 g 400 g 730 g

12,43cm
b
MOUNTING e

1. Mount the manometer on a wall or partition wall with two maximum Ø 5 screws.
2. Unscrew the left-hand connector and slowly pour the manometric liquid to zero point on the
graduation
3. Remount the connector without overtightening.
4. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression source to
be checked.

REMARQUES : d
c
For a pressure measurement..............................Connect the crystal tube to one of the two connectors
For a depression measurement..........................Connect the crystal tube to one of the two connectors.
For a differential pressure measurement...........Connect both tubes to both connectors

DigiParts GmbH www.digiparts.ch info@digiparts.ch


MG series
INCLINED LIQUID
COLUMN MANOMETERS

Pressure / Depression

The MG range of inclined liquid column


manometers, developed and manufactured by
KIMO, measure slight variations in pressure,
depression or differential pressure of air or gas.
They are for use in the following applications :
treatment of air, ventilation, air conditioning,
heating, dust elimination...

KEY POINTS


Zero adjustement by moving the slide strip
● Safety reservoir enabling momentaneous overshooting of the scale
● Integrated spirit level for adjusting horizontality
● Supplied with a white PVC support, two screws and two rawplugs, two 487 connectors and a bottle of AWS 10 liquid

MEASURING RANGE

Measuring range* Sensitivity scale


Reference Resolution
mm CE Pascal For 1 mm CE or 10 PA
MG 20 0 – 20 0 – 200 8 mm 0,5 mm CE or 5 Pa
MG 50 0 – 50 0 – 500 3 mm 1 mm CE or 10 Pa
MG 80 0 – 80 0 – 800 2.5 mm 1 mm CE or 10 Pa

* Also exists in DaPa

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TECHNICAL FEATURES
Recommended range of use From +5 to +30°C
Possible range of use From -30 to +60°C
Maximum static pressure 6 bars
Manometer body Transparent 15 mm thick Altuglas
Liquid column Entirely bored in the solid block, Ø 4 mm
Graduated slide strip Transparent Altuglas. Cross-section 20 X 2 mm
Zero adjustment By moving the graduated slide strip, travel 20 mm.
Fixed via milled, nickel-plated brass screw
Positionning Horizontal positioning via integrated spirit level and milled, nickel-plated brass adjusting screw,
vertical travel 12 mm.
Manometric liquid AWS 10 red oil, density 0.87 at 15°C

Ref. FTang – MG – 17/08/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Reservoir capacity 20 ml
Connection Ø 5 X 8 mm semi-rigid crystal tube, on Ø 6,2 mm ribbed, nickel-plated brass connectors, 1/8
gas thread
Wall-mounted With or without white PVC support

DIMENSIONS
a
Ø 6 mm
Cylindrical 1/8 gas connector
Ø 6.2 mm ribbing
b

c
f

e
d

Reference MG 20 MG 50 MG 80
a 196 mm 178 mm 219 mm
b 128 mm 110 mm 151 mm
c 80 mm 117 mm 154 mm
d 25 mm 25 mm 25 mm
e 192 mm 174 mm 215 mm
f 55 mm 109 mm 129 mm
Weight 320 g 420 g 660 g

MOUNTING

1. Mount on a wall or a vertical partition wall with two maximum Ø 5 x 25 mm screws (supplied).
2. Set horizontality using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. Connect the manometer with the Ø 5 X 8 mm crystal tube to the pressure or depression source to be checked.
NOTE :
For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)
MAINTENANCE :
MG manometers require no special maintenance other than simply changing the reading liquid once a year.

DigiParts GmbH www.digiparts.ch info@digiparts.ch


MT40
INCLINED LIQUID
COLUMN MANOMETERS
Pressure / Depression

The MT range of inclined liquid column portable


manometers, developed and manufactured by
KIMO, are particulary recommended for those in
the heating trade for checking pressures in
chimney flues, combustion chambers, filters...

KEY POINTS


Easy to carry
● Safety reservoir enabling momentaneous overshooting of the scale
● Zero adjustment by moving the slide strip
● Integrated spirit level for adjusting horizontality.
● Equipped with valve connectors, magnetic fixations, support with base plate

Can be used for measuring speeds with Pitot tube.
● Supplied with connecting sleeves, bottle of VOLT 1 S liquid and travelling case.

MEASURING RANGE

Sensitivity scale
Reference Measuring range (mm CE) Résolution
For 1 mm CE
MT 40 0 – 40 4 mm 1 mm CE

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TECHNICAL FEATURES
Recommended range of use From +5 to +30°C
Possible range of use From -30 to +60°C
Maximum static pressure 6 bars
Manometer body Transparent 15 mm thick Altuglas
Liquid column Entirely bored in the solid block, Ø 4 mm
Graduated slide strip Transparent Altuglas. Cross-section 20 X 2 mm
Zero adjustment By moving the graduated slide strip, travel 20 mm.
Fixed via milled, nickel-plated brass screw
Positionning Horizontal positioning via integrated spirit level and milled, nickel-plated brass adjusting screw,
vertical travel 12 mm.
Manometric liquid VOLT 1S oil - density 1.86 at 20°C.

Ref. FTang – MT – 17/08/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Reservoir capacity 20 ml
Connection on valve connectors in nickel-plated brass Ø 6.2 mm neoprene tubes with connecting sleeves.

DIMENSIONS
a
Cylindrical 1/8 gas connector
Ø 6.2 mm ribbing

c e

d
b

Reference a b c d e Weight
MT 40 193 mm 208 mm 93 mm 37 mm 80 mm 800 g

MOUNTING

1. Place the manometer on a horizontal surface or a vertical partition wall by using the magnetic fixations.
2. Set horizontality by using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slacken the milled wheel on the other connecter by one turn.
4. Slowly pour the manometric liquid to zero point on the graduation.
5. Remount the connector without overtightening.
6.Connect the manometer with the tube provided to the pressure or depression source to be checked.

NOTE :
For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)
MAINTENANCE :
MT40 manometer requires no special maintenance other than simply changing the reading liquid once a year.

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TJ series
VERTICAL LIQUID
COLUMN MANOMETERS

Pressure / Depression

KEY POINTS

The TJ range of vertical liquid column manometers, developed and manufactured by KIMO,
are mainly for measuring variations of pressure, depression or differential pressure of air or
gas within measurement ranges which vary according to the type of manometric liquid used :
AWS 10, VOLT 1S or MERCURY.
(See table below)


"J"- shaped column for direct measuring.
● Zero adjustment by moving the slide strip.
● For fixed use regardless of the manometric liquid used.
● For portable use with the TJ model using VOLT 1S liquid.
●Supplied with a white PVC support, 2 screws and 2 rawlplugs, two 487 connectors
and a bottle of liquid.

MEASURING RANGE

TJ 100 TJ 150 TJ 300 TJ 600 TJ 1000


Measuring mm CE 0 – 100 0 – 150 0 – 300 0 – 600 0 – 1000
AWS 10 range mbar 0 – 10 0 – 15 0 – 30 0 – 60 0 – 100
liquid
Resolution : 1 mm CE or 0.5 mbar
Measuring mm CE – – 0 – 650 0 – 1300 0 – 2150
VOLT 1S range mbar – – 0 – 65 0 – 130 0 – 215
liquid
Resolution : 5 mm CE or 1 mbar
Measuring mm HG – – 0 – 350 0 – 690 0 – 1160
Mercury range mbar – – 0 – 470 0 – 920 0 – 1550
Resolution : 1 mm HG or 10 mbar

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TECHNICAL FEATURES

Recommended range of use From +5 to +30°C


Possible range of use From -30 to +60°C
Maximum static pressure 6 bars
MAnometer boy Transparent 15 mm thick Altuglas
Liquid column Ø 4mm tube in extruded Altuglas.
Graduated slide strip Transparent Altuglas. Cross-section 23 x 3 mm.
Zero adjustment moving the gratuated slide strip, travel 15 mm
Fixed in place via milled, nickel-plated brass screw.
Reservoir capacity 20 ml
Manometric liquid AWS 10 liquid, density 0.86 ; VOLT 1S liquid, density 1.86 or mercury, density 13.545
Connection Ø 5x8 mm semi-rigid crystal tube on Ø 6.2 nickel-plated brass ribbed connectors (for
manometers using AWS 10 or VOLT 1S liquid) or in Delrin (for mercury manometer), 1/8 gas

Ref. FTang – TJ – 17/08/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
thread.
Wall-mounted With or without white PVC support.

DIMENSIONS
a
Cylindrical 1/8 gas
REF. TJ 100 TJ 150 TJ 300 TJ 600 TJ 1000
connectors.
a 57 mm 57 mm 57 mm 57 mm 57 mm
b 185 mm 243 mm 430 mm 777 mm 1239 mm
c 25 mm 25 mm 25 mm 25 mm 25 mm
d 52 mm 52 mm 52 mm 52 mm 52 mm Ø 6 mm
e 147 mm 205 mm 392 mm 739 mm 1201 mm
Distance between
tubes 171 mm 229 mm 416 mm 763 mm 1225 mm
Weight 290 g 310 g 450 g 790 g 1280 g

b
e

MOUNTING

1. Mount the manometer on a wall or partition wall with two maximum Ø 5 screws.
2. Unscrew one of the two connectors and slowly pour the manometric liquid to zero point on
the graduation.
3. Remount the connector without overtightening
4. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression
source to be checked.

NOTE :

For a pressure measurement..................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..............Connect the crystal tube to the left-hand connector (-)
For a differential pressure......................Connect the highest pressure to the right-hand connector(+)
and the lowest pressure to the left hand connector (-)
d c

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TX series
INCLINED LIQUID
COLUMN MANOMETERS

Pression / Dépression

The TX range of inclined liquid column


manometers, developed and manufactured by
KIMO, measure slight variations in pressure,
depression or differential pressure.
They are particulary recommended for
measuring overpressures and depressions in
clean rooms, operating blocks, laboratories,
aseptic rooms, laminar flows...

KEY POINTS

Scale with centered zero
● Possibility for measuring positive and negative pressures
● High measurement sensitivity

Very low pressure ranges
● Zero adjusting by moving the slide strip

Integrated spirit level for adjusting horizontality
● Supplied with a white PVC support, 2 screws and 2 rawlplugs, two 487 connectors and a bottle of AWS 10 liquid.

MEASURING RANGE

Measuring range Sensitivity scale


Reference Resolution
mm CE Pascal For 1 mm CE or 10 PA
TX 25 2.5 – 0 – 2,5 25 – 0 – 25 20 mm 0.1 mm CE or 1 Pa
TX 50 5–0–5 50 – 0 – 50 15 mm 0.1 mm CE or 1 Pa
TX 75 7.5 – 0 – 7.5 75 – 0 – 75 10 mm 0.1 mm CE or 1 Pa

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TECHNICAL FEATURES

Recommended range of use From +5 to +30°C


Possible range of use From -30 to +60°C
Maximum static pressure 6 bars
Manometer body Transparent 20 mm thick Altuglas
Liquid column Entirely bored in the solid block, Ø 4mm.
Graduated slide strip Transparent Altuglas. Cross-section 20 x 2 mm
Zero adjustment By moving the graduated slide strip, travel 12 mm.
Fixed in place via milled, nickel-plated brass screw.
Positioning Horizontal positioning via integrated spirit level and milled, nickel-plated brass adjusting screw,
vertical travel 12 mm.
Manometric liquid AWS 10 red oil, density 0.87 at 15°C.

Ref. FTang – TX – 02/99 A - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Reservoir capacity 20 ml
Connection Connection : Ø 5x8 mm semi-rigid crystal tube, on Ø 6.2 mm ribbed, nickel-plated brass
connectors, 1/8 gas thread
Wall-mounted With or without white PVC support.

DIMENSIONS
a
Référence TX 25 TX 50 TX 75
b
a 184 mm 234 mm 234 mm
b 116 mm 166 mm 166 mm
c
c 80 mm 80 mm 80 mm
f d 30 mm 30 mm 30 mm
e 180 mm 230 mm 230 mm
f 71 mm 71 mm 71 mm
e poids 340 g 430 g 430 g
d

MOUNTING

1. Mount the manometer on a wall or a vertical partition wall with two maximum Ø 5 x 25 mm screws.
2. Set horizontality by using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression source to be checked.

NOTE :
For a pressure measurement..............................Connect the crystal tube to the right-hand connector (+)
For a depression measurement..........................Connect the crystal tube to the left-hand connector (-)
For a differential pressure..................................Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)

MAINTENANCE :
TX manometers require no special maintenance other than simply changing the reading liquid once a year.

DigiParts GmbH www.digiparts.ch info@digiparts.ch


VH series
INCLINED LIQUID
COLUMN MANOMETERS

Pressure / Depression

The VH range of inclined liquid column


manometers, developed and manufactured
by KIMO, measure slight variations in
pressure, depression or differential pressure
of air or gas.
They are particulary recommended for
checking clogging of filters in the ventilation
and dust elimination industry.

KEY POINTS


Horizontale V-shaped liquid column.
● Dual measuring range

Different sensitivity on the two measuring ranges
● Zero adjustment via float
● Compact dimensions

Integrated spirit level for adjusting horizontality

Supplied with a white PVC support, 2 screws and 2 rawlplugs, two 487 connectors and a bottle of AWS 10 liquid.

MEASURING RANGE

Measuring range Sensitivity scale


Resolution
Reference mm CE Pascal For 1 mm CE or 10 PA
Total 1st column 2nd column Total 1st column 2nd column 1st column 2nd column 1st and 2nd column
VH 50 0 – 50 0 – 16 19 – 50 0 – 500 0 – 160 190 – 500 7 mm 3.5 mm 1 mm CE or 10 Pa

The VH 50 also exists in DaPa.

DigiParts GmbH www.digiparts.ch info@digiparts.ch


TECHNICAL FEATURES

Recommended range of use From +5 to +30°C


Possible range of use From -30 to +60°C
Maximum static pressure 1 bar
Manometer body Transparent 15 mm thick Altuglas.
Liquid column Entirely bored in the solid block, Ø 4 mm.
Graduation Directly silk-screened onto the rear face.
Zero adjustment By moving the Altuglas float and the milled, nickel-plated brass screw, travel 10 mm.
Positioning Horizontal positioning via integrated spirit level and milled, nickel-plated brass adjusting screw,
vertical travel 12 mm.
Manometric liquid AWS 10 red oil, density 0.87 at 15°C.

Ref. FTang – VH – 17/08/11 - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Reservoir capacity 20 ml
Connection Ø 5x8 mm semi-rigid crystal tube, on Ø 6.2 mm ribbed, nickel-plated brass connectors,
1/8 gas thread.
Wall-mount With or without white PVC support.

DIMENSIONS
a
Ø 6 mm
b Reference VH 50
Cylindrical 1/8 gas a 188 mm
connector
c b 120 mm
4cm

Ø 6.2 mm ribbing
3.68cm

f c 112 mm
d 25 mm
e 182 mm
f 101 mm
6.88cm
e Weight 380 g
d

MOUNTING

1. Mount the manometer on a wall or a vertical partition wall with two maximum Ø 5 screws.
2. Set horizontality by using the integrated level and the milled adjusting screw.
3. Unscrew the connector on the reservoir and slowly pour the manometric liquid to zero point on the graduation.
4. Remount the connector without overtightening.
5. Connect the manometer with the Ø 5x8 mm crystal tube to the pressure or depression source to be checked.

NOTE :
For a pressure measurement.............................. Connect the crystal tube to the right-hand connector (+)
For a depression measurement.......................... Connect the crystal tube to the left-hand connector (-)
For a differential pressure.................................. Connect the highest pressure to the right-hand connector (+) and the lowest pressure to the left
hand connector (-)

MAINTENANCE :
VH manometers require no special maintenance other than simply changing the reading liquid once a year.

DigiParts GmbH www.digiparts.ch info@digiparts.ch


ACCESSORIES FOR MANOMETERS

TUBES

Ref. TS 4 X 7
Ref. TC 5 X 8
Clear tube Ø 5 x 8, for permanent installation (m/l or 25 m).

Silicone tube Ø 4 x 7 in black or white, for


test instruments (m/l).

MANOMETER LIQUIDS

Ref. AWS 10
Density = 0,87. Bottles of : 20 ml, 30 ml,
125 ml, 250 ml, 500 ml, 1000 ml.

Ref. VOLT 1S
Density = 1,86. Bottles of : 10 ml, 20 ml, 30
ml, 125 ml.

Ref. HG
Density = 13,545. Bottles of :
10 ml, 20 ml, 30 ml, 125 ml.

Ref. VF1
Density = 1. Bottles of : 20 ml, 30 ml, 125
ml, 250 ml, 500 ml, 1000 ml.

Ref. TETRA BROMURE


Density = 2,96. Bottles of : 20 ml, 30 ml,
125 ml.

PRESSURE CONNECTIONS :

Ref. 482
Ref. DP 339 Simple conection with rear nut, M5
Ref. KR 483 Connection for double-shell wall threading, length 15 mm. Drilling diameter :
Connection kit with 2 quick connections n° maximum thickness : 80 mm. Drilling 5 mm.
483 and 2 m of clear tube. diameter : 6 mm.

Ref. PC 482
Ref. 483 Through-connection for partitions standard
Ref. DP 447
Quick-connection for wall without rear lengths 35 to 190 mm.
Connection for double-shell wall, maximum
access. Other lengths on request.
thickness : 30 mm.
Drilling diameter : 10 mm. Drilling diameter :11 mm.
Drilling diameter : 6 mm.
DigiParts GmbH www.digiparts.ch info@digiparts.ch
MANOMETERS CONNECTIONS :

Ref. 487 Ref. 505


Simple connection in chromed brass for all Valve connection in chromed brass for Ref. 466
type of manometers using AWS 10 and portable MT, KM, TJ and LU Simple connection in nylon for GF
VOLT 1S. Thread : 1/8 gas. manometer using VOLT 1S liquid. manometers, using VF1 and HG liquid.
Thread : 1/8 gas. Thread : 7 x 100.

Ref. 509
Chromed brass safety connection,

Ref. FTang – Accessoires – 02/05 B - RCS 24 (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
eliminating overspill on manometer using
AWS 10 and VOLT 1S. Ref. 484
Thread : 1/8 gas. Simple connection in nylon for TJ and
LU mercury manometers.
Thread : 1/8 gas.

Ref. 555 M/F


Male / female, 1/8 gas ball valve, for
manometer isolation.

Ref. 555 F/F Ref. 666


Female / female, 1/8 gas ball valve, for Male / female, 1/8 connection,
manometer isolation. air vent valve with a slide block to set
the zero point without disconnecting
the tubes.

JUNCTIONS

Ref. J.D.C
Straight connection for Ø 5 x 8 tube.
Ref. J.T.C Ref. J.Y.C
T-connection for Ø 5 x 8 tube. Y-connection for Ø 5 x 8 tube.

ACCESSORIES

Ref. 648-FM
Ref. 494 Ref. FM-KS.10
Safety reservoir, with magnetic fixings for
Pressure tube, length 1 m for MT and KM Set of 2 magnetic fixings.
mercury manometers.
manometers. With moulded ends.

Ref. 648-PF
Ref. GPN 900 Ref. ALTU.
Safety reservoir, permanent fixing for
Plug -8,5 A for all Ø 6,2 mm connections. Altunet cleaning product, 500 ml bottle..
mercury manometers.
10 units bag.

DigiParts GmbH www.digiparts.ch info@digiparts.ch

You might also like