You are on page 1of 3
STANDARDS REFERENCE ~BS EN 81-20:2014 © Machines &Pulley Space v 2) 3) 4) 5) 6) 7 8) 9) © CAR 2.10M-clear height of working areas of machine rooms{5.2.6.3.2.1] (0.30M-vertical distance between in protected rotating parts of the machine[5.2.6.3.2.3] 0.5 OHM-continuity of resistance check for earthing 30 MA(not exceeding)- RCD(Residual current protective device [5.10.1.2.3] 200 LUX-Lighting intensity in machinery spaces and pulley rooms(S.2.1.4.2] gn and 2gn- Average retardation in case of free fall with rated load (progressive safety gear){5.6.2.1.3) . Tripping of over speed governor for the safety gear at least equal to 115% of the rated speed [5.6.2.2.1.1] .2)0.8 m/s for instantaneous safety gears except for the captive power type 'b)1 m/s for safety gears of the captive Roller ©)1.50m/s for progressive safety Gear used for rated speeds not exceeding 1.0m/s 4)1.25v+0.25/v expressed in meters per second, for progressive safety gears for rated speed exceeding 1.0m/s Protection means against unintended or movernent away from landinglif any)[5.6.7.5] @)1.20M-Stopping distance (shall not exceed) from landing wear the intended car ‘movement has been detected )200mm(shall Not Exceed)-vertical distance between landing sill and the lowest(shall not exceed)part of the apron ©)200mm(in case of enclosures shall not exceed)- lowest part of the well wall facing car entrance 4)1.0M[shall not be less than)-Vertical distance from car sill to landing sill to car door lintel! Braking system:(Electro-Mechanical brake)[5.9.2.2.2.3] To hold off the brake shall require a continuous flow of current except As permitted by (59.22.27) The following shall be met: a)The interruption of this current ,initiated by an electric safety device as required in(S.11.2.4)shall be made by one of the following means: Two independent electromechanical devices according to(S.1.0.3.1) whether or not integral with those, which cause interruption of the current feeding the lift machine If whilst the lift stationary, one of the electromechanical device has not opened the brake circuit any further movement of the car shall be prevented. a stuck at failure of this monitoring function shall have the same Result. istance between car sill and the ‘over toad shall be detected at the latest when the rated load is exceeded by 10% with a ‘minimum of 75kg{5.12.1.2.2] Page 2of 7 )) 2)150N-Effort need to prevent car door closing excluding frst third of travell5.3.6.2.2.1] 3)100 LUX-Intensity of car light on the control devices and atin above the floor at any point ‘not less than 100mm from any walll5.4.10.1] 4) 5 LUX (For1Hrs)-Intensity of emergency light of car with an automatically rechargeable emergency supply[5.4.10.4) © Car Apron{5.4.5] 1)0.75m- Height of the vertical portion. i 2}20mm(not les than) ~chamfer projection of the horizontal plane. ‘+ Car Top And Inside Well 1)Car Roof: 2000N-Car roof shall resist minimum force at any postion on an car roof balustrade on an ‘Area of 0.30X0.30m with out any permanent deformation [5.4.7.1] + Car Roof Balustrade (5.4.7.4.7] shall consist ofa handrail and an intermediate barat half the height ofthe balustrade b}Considering the fre distance n a horizontal plane beyond the inner edge ofthe handrail of the balustrade and well wall its height shall at least: 0.70M where the distance is up to 0.50m 1.10m where the distance exceeds 0.50m ¢)Balustrade shall be located at a maximum distance 0.15m from the edges ofthe car root. )The horizontal distance between the outer edge of the handrail and any part in the well{counterweight ,switches ,Rails Bracket Etc)shall at least 0.10m ‘+ _ Dimension of Refuge Spaces In Headroom:5.2.5.7.3] When the car is at its highest position according to[S.2.5.6] 2)The highest pieces of equipment fixed on the roof, except for those covered in b and a below ‘shall be at east 0.50m in any vertical or inclined direction within the projection of the care b)The highest part ofthe guide shoes or rollers ofthe rope terminations and of the header or Parts of vertically sliding doors ,f any shall be atleast 010m in any vertical direction within a horizontal distance of 0.40m with the projection of the car ¢)The highest part of the balustrade shall be at least 0.30m within a horizontal distance of 0.40m within the projection of the car an 0.10m the outside of the balustrade 0.50m in any inclined distance beyond 0.40m within the projection of the car © Landing Door 1) 35mm(shall not exceed)-Horizontal distance between sill ofthe car and sll of the landing doors(5.3.4.1] 2) Tmm-Landing door locking elements shal at least engaged before electric safety device activate[5.3.9.1.2] Page dof 7 3) When closed the clearance between door panels or between panels and uprights lintels orsills, shall not exceed 6mm.this value due to wear ,may reach 10 mm.with exception of doors made from glass[5.3.1.4] = pit 1) Pitis more than 1.60m two switches shall be provided [5.2.1.51] ‘a)upper switch-1.0m above lowest landing floor and horizontal b)Lower switch -1.20m above pit floor distance of maximumo.75m from the door frame inner edge: 2), Car and counterweight buffers a)Energy accumulation type buffers{5.8.2} -Buffers with linear characteristics (5.8.2.1.1] - Total possible stroke of the buffer shall be at least equal to twice the gravity stopping distance corresponding to 115% of the rated speedi(0.135v2)]Sstroke expressed in meters[5.8.2.1.1.1] Stroke shall not less than 65mm. -Buffer shall be Designed to cover the stroke defined in (5.8.2.1.1:1) under static load of between 2.5 times and 4 times the sum of the mass of the car and its rated load(or mass of the counterweight) b)Energy Dissipation Type Buffers{5.8.2.2] 41)Total possible stroke of the buffers shall be at least equal to the gravity stopping distance corresponding to 115% of the rated speed (0.0674v2)stroke expressed in meters. Energy dissipation type buffers shall fulfil the Following requirements{S. 3] 2)Hitting the buffer with the mass of the car with its rated load in case of free fall with a speed of 115% of the rated speed, average retardation shall notbe more * than ign 2)Retardation of more than 2.5gn shall not be longer than 0.04 '3)There shall be no permanent deformation after actuation 9.81m/s2-standard acceleration of free fall. - The Machine shall Be Capable of Having The Break Released by a continuous Manual operation. The ‘can be Mechanical( E.g Lever) or electrical powered by an automatically rechargeable opera emergency supply.[5.9.2.2.2.7] -An electric safety device when operated shall imitate immediately stopping of the machine and prevent its setting in motion.[5.11.2.4] Page Gof 7

You might also like