AHTS GARNET FLAG STATE INSPECTION CLOSER

REPORT
S.NO ITEMS ACTIONS REMARK
Spare magnetic compass was sent ashore
for servicing on 18.08.2021 (landing report).
Spare Magnetic Compass found to be having large deviation Again same sent ashore for servicing on Awaiting for cert and equipment
1. from heading as shown in the main magnetic compass 13.10.2023 after servicing.
Fire detection system ,steering gear alarm and engine
control room alarm panel found to be showing continuous
2. alarm Pending
The outer hard shell near RR tape was
inspected, found damaged. Requisition for
3. Some of the life buoy found to be damaged 03 lifebuoy was raised on 13.10.2023. Awaiting for supply
EPIRB was removed for visual inspection by Completed on 13.10.2023
Ch officer (IV master). While fitting back, ( Image attached)
locking arrangement was not proper
4. EPIRB securing mechanism found to be damaged inserted. Same checked & satisfactory.
Bridge is supplied with 04 no’s VHF, 02
ICOM not connected with GPS, manual posn ICOM vhf now feed with current
& time can be fed & 02 Furuno connected position and date.
with GPS which is automatically updating
position and time. (Image attached).
5. VHF found to be having incorrect date and time
Leakage found in exhaust lines of the auxiliary engines and
6 hydraulic lines found in the engine room and steering room Leakages rectified Images attached.
As the vessel is under harbour manning,
medicines provided for daily uses. Important
medicines was provided to the vessel. For
any problem, crew is sent ashore to Awaiting for supply. medicines
Medicines not found the vessel asper applicable merchant company medical doctor. Requisition raised as per DG guidelines, schedule
7 shipping notices on 13.10.2023. III dated 24.10.1994
Vessel was provided with work done
Record of annual servicing rescue boat and davit not found inspection report, awaiting for original
8 on board the vessel certificates from the SHM. Awaiting for the certificate.
SHM workshop boarded vessel on Awaiting for the certificate.
No record of air purity test of the compressor used for the 06.10.2023 for servicing of SCBA items.
filling the self contained breathing apparatus SCBA found Taken sample for lab testing.
9 onboard the vessel
As per the statement of the Master some of the portable fire All FFA sent ashore received on 13.10.2023
extinguisher are landed ashore for servicing ,Also wet after pressure testing & services. Wet
chemical firefighting systems servicing and firefighting foam Chemical connected to fixed firefighting
10 analysis is under progress system for Galley. Completed 14.10.2023
Servicing was done by workshop on 29 Nov
Chain register not found on board the vessel. Also no record 2021 but not provided with chain register.
of servicing of the main deck crane found on board the Requested workshop to board vessel for test
11 vessel load of deck crane. Awaiting for workshop.
As per PMS, visual inspection is done on
monthly basis by Master/ Ch officer. Pilot
ladder is supplied on 18.12.2021 and
No record of servicing of the pilot ladder, embarkation ladder gangway load test on 29.11.2021.
12 and gangway found on board the vessel Requested Workshop to board Awaiting for workshop.