GENERAL

GRADING, DRAINIAGE AND FOUNDATION SYSTEM ARE AS PER CONCRETE


DOC. CA3949538 (COVENANT) MATERIAL MUST COMPLY TO CSA-A23.1-04
CONTRACTORS ARE TO ENSURE THEY ARE WORKING FROM WORK MUST COMPLY TO CSA-A23.1-9 AND A23.2-9
CURRENT “ISSUED FOR CONSTRUCTION” PLANS. USE NEW REINFORCING BARS AS PER CSA G30.18-09 GRADE 400
THE CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED ALL REINFORCING STEEL MUST BE SECURED IN FINAL POSITION BEFORE POURING
WITH THE CORRECTION OF DEFICIENCIES.
ENGINEER MUST APPROVE SOIL BEFORE POURING
THE CONTRACTOR IS RESPONSIBLE FOR SAFETY ON THE JOB SITE
DURING CONSTRUCTION AND SHALL ENSURE COMPLIANCE TO COMPRESSIVE STRENGTH = 32 MPA
CURRENT WORKSAFEBC REGULATIONS. AIR CONTENT 4-7% (EXTERIOR)
GOVERNING CODES: BC BUILDING CODE 2012 INCLUDING ALL AIR CONTENT 1-4% (INTERIOR)
AMENDMENTS AND MUNICIPALS BYLAWS.
MAX SIZE AGGREGATE = 19 MM. COMPLY WITH ASTM C 33.
THIS SLAB AND THE RETAINING WALL HAVE BEEN DESIGNED TO
SLUMP = 60 - 100 MM.
DIVISION B, PART 4 OF BC BUILDING CODE 2012

HELICAL PILES
DESIGN LOADS
ALL MATERIAL MUST COMPLY TO ASTM A252 GRADE 3
THIS SLAB HAS BEEN DESIGNED FOR THE FOLLOWING
SUPERIMPOSED SERVICE LOADS: INSTALLATION TO BE SUPERVISED BY THE ENGINEER OR HIS/HER REPRESENTATIVE
PILES TO BE INSTALLED VERTICALLY, MAX SLOPE WITH THE VERTICAL AXIS IS ± 2°

ROOF LOADS LAYOUT OF PILES ON THE GROUND WILL BE COMPLETED BY OTHERS AS PER BC
FOUNDATIONS DRAWINGS
SS = 2.4 KPA
ALLOWABLE CAPACITY PER PILE IS 50 KN
SR = 0.2 KPA
ULTIMATE CAPACITY PER PILE IS 100 KN
DEAD LOAD = 1.0 KPA
REQUIRED TORQUE PER PILE (MIN) = 3000 FT.LBS
RAIN LOAD = 0.2 KPA
PILES ARE AS PER ASTM A252, BARE STEEL
SHAFTS ARE 2-7/8" X SCHD 40
FLOOR LOADS
DEAD LOAD = 1.0 KPA
INSPECTIONS
LIVE LOAD = 2 KPA
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ARRANGE WITH BCF&PHP LTD. TO
LIVE LOAD (GARAGE) = 6 KPA
INSPECT COMPLETION OF THE FOLLOWING:
1) SITE GRADING FOR FOUNDATION
WIND LOADS
2) LAYOUT OF PILES – POINT LOADS FOR THE FRONT AND THE BACK OF THE HOUSE
1/50 HOURLY PRESSURE = 0.4 KPA Legal Description: PL EPP33926 LT A SEC 31 TWP 19 RGE 17 MER 6 KAMLOOPS
3) INSTALLING FORMS FOR FOUNDATIONS
1/10 HOURLY PRESSURE = 0.3 KPA CIVIC ADDRESS: 680 MONARCH DR., KAMLOOPS, BC.
4) INSTALLING REBARS
EXPOSURE = ROUGH TERRAIN
5) POURING CONCRETE (DURING AND AFTER)
6) INSTALLING INSULATION
7) INSTALLING PARAMETER DRAIN TILE
FOUNDATIONS
8) INSTALLING GUTTERS AND DOWNSPOUTS
DESIGNED FOR DEEP FOUNDATIONS (HELICAL PILES)
9) FINAL GRADING FOR THE FRONT AND BACK YARDS
ANY EXCAVATION MUST BE APPROVED BY BC FOUNDATIONS
PRIOR TO START
ANY BACKFILLING MUST BE TYPE 1 FILL AND COMPACTED TO A
MIN OF 98% STANDARD PROCTOR ASTM D698
THE ENGINEER OF RECORDS MUST APPROVE ANY MATERIAL PRIOR
TO START BACKFILLING

BC FOUNDATIONS & PROVINCIAL HELICAL PILES LTD REVISIONS


2591 PARKCREST AVE. KAMLOOPS, BC V2B 4Y4

01
MM/DD/YY REMARKS
INFO@BCFOUNDATIONS.CA T: 250-377-5417 1 05/14/20 ISSUED AND REVIEWED BY NG
GENERAL NOTES BCFOUNDATIONS.CA & PROVINCIALHP.CA 2 06/03/20 REVISED AS PER DOC. CA3949538

3 _ _ /_ _ /_ _ ...
PROJECT ADDRESS: 680 MONARCH DRIVE

S
4 _ _ /_ _ /_ _ ...
KAMLOOPS, BC 5 _ _ /_ _ /_ _ ...
DISCHARGE RAIWATER AND GROUNDWATER THROUGH
A SOLID PIPE TO THE CITY STORM WATER SYSTEM PERFORATED PIPE FOR FOUNDATION DRAINAGE
STORM WATER COLECTION AS PER DOC. CA3949538:
PERFORATED AROUND THE PERIMETER OF THE FOUNDATIONS

LEGEND
SOLID PIPE TO DISCHARGE THE RAINWATER AND GROUND WATER
TO THE SANITARY SYSTEM
SANITARY COLLECTION

ST
19' 8-1/4" (6M)

SA

3.000'

SOILD PIPE (PVC 4" OD.)

SLOPE (GRADIENT)
WATER MAIN

PERFORATED PIPE (PVC 4" OD.)

DOWNSPOUT
WM

50%
50%

50%
EASEMENT SWALE

5.000'
SWALE

2%
2%
2%
2%
2%
MONARCH DRIVE

DRIVEWAY

BOTTOM ELEV. = 620.143 M


TOP ELEVATION = 620.600 M (COVENANT)
THICKENED SLAB FOUNDATION
2%
%
50

BACKYARD
ELECTRICAL/CABLE POLE

TOP ELEV. 620.600


%
2% 50

GARAGE

BACKYARD
TOP ELEV. 620.600

N
TOP ELEV. 620.602

TOP ELEV. 620.600


'
000
8.
GARAGE

GARAGE

2% 2%

10.000'

5' 5" (1.5 m) SETBACK


RETAINING WALL
TOP ELEV. = 622.429
BOT. ELEV. = 619.034

19' 8-1/4" (6.00M) SETBACK

BC FOUNDATIONS & PROVINCIAL HELICAL PILES LTD REVISIONS


2591 PARKCREST AVE. KAMLOOPS, BC V2B 4Y4

02
MM/DD/YY REMARKS
INFO@BCFOUNDATIONS.CA T: 250-377-5417 1 05/04/20 DRAWING ISSUED (LM)
GRADING PLAN SCALE: 1:70 BCFOUNDATIONS.CA & PROVINCIALHP.CA 2 05/10 /20 FIRST REVISION (NG)

3 05/20/20 SECOND REVIEW (NG)


PROJECT ADDRESS: 680 MONARCH DRIVE 06/03/20 THIRD REVISION (NG) - REVISED AS PER DOC. CA3949538

S
4
KAMLOOPS, BC 5 _ _ /_ _ /_ _ ...
11.010' (TO BE CHECKED) 11.452' (TO BE CHECKED) 11.380' (TO BE CHECKED) 11.052' (TO BE CHECKED)

P39

0.499'
P41 P40
P42
P43

12.061'
67.292'

10.203' 10.849' 8.772' 10.755' 8.500' 8.500' 8.760'


P8
P1

P2 P3 P4 P5 P6
P7

10.192'

10.634'
S10 S7
S9 S8 S6
S11

20.605'
P21

P9
10.167'

5' S12 S13 S14 P28


6' P27
S15
42.266'

1'
P23
2-3/5" OD P22 2-3/5" OD
P20 EXTRA PILE EXTRA PILE
FOR ICF WALLS FOR ICF WALLS P10
2-3/5" OD
EXTRA PILE
FOR ICF WALLS
10.583'

8.964' 8.917'

11'
S18
S17 S16
P24

S1
P11
P25 P29
P19 P26

2-3/5" OD
EXTRA PILE
FOR ICF WALLS

10.080'
10.333'

11'
10.727' 10.667'

P18
P12 S2
P14 P13
P30

44.333'
P17 P15
P16
1'
12'
6.359'

11.250'

P37
P38

11'
S5
NOTES: 11.917' (TO BE CHECKED)
1) PILES P1 TO P44 ARE FOR BEARING WALLS (GARAGE AND HOUSE) S4
S3
2) PILES S1 TO S18 ARE FOR CONC. FLOORS (GARAGE AND HOUSE)
3) TOTAL PILES ARE 62 PILES - ALL PILES ARE 2-7/8" X SCHD 40 AS PER ASTM A252 MIN P31
4) PILES P7 TO P43 (POINT LOADS), LOCATIONS MUST BE APPROVED BY THE BUILDER BEFORE MARKING ON THE GROUND P44
5) CAPACITY PER PILE IS 50 KN ALLOWABLE AND 100 KN ULTIMATE.
6) PILES WILL BE MARKED AFTER EARTH WORK IS COMPLETED TO GRADE
7) THIS PLAN CPLIES WITH DOC. CA3949538 (THE COVENANT).
11.50'

10.44'
11.719' 12.260' 11.219' 9.740'

P36 P35
P34 P33 P32

BC FOUNDATIONS & PROVINCIAL HELICAL PILES LTD REVISIONS


2591 PARKCREST AVE. KAMLOOPS, BC V2B 4Y4

03
MM/DD/YY REMARKS
INFO@BCFOUNDATIONS.CA T: 250-377-5417 1 05/04/20 DRAWING ISSUED (LM)
PILES LAYOUT SCALE: 1" = 2' BCFOUNDATIONS.CA & PROVINCIALHP.CA 2 05/11/20 FIRST REVISION (NG)

3 05/20/20 SECOND REVISION (NG)


PROJECT ADDRESS: 680 MONARCH DR.

S
4 06/03/20 THIRD REVISION (NG) - REVISED AS PER DOC. CA3949538
KAMLOOPS, BC 5 _ _ /_ _ /_ _ ...
101

TOP BARS AS PER DETAILS


3' LAP AT MIDSPAN ONLY 3' LAP
67.292'
DO NOT SPLICE AT PILE CAPS MIN LAP LENGTH ( in)
BAR
12" TYP CONC. STRENGTH( MPa)
SIZE
25 30 35
3' LAP
10M 16" 16" 16"

(HOOK EA. END DOWN 12")


15M 24" 24" 24"
18" TYP FOR ALL PERIMETER AND INTERNAL BEAMS

101
20M 30" 30" 24"
BEAM ABC 25M 36" 33" 30"

@ 15" o/c BOTTOM


103

10M X 20.359' LG
HELICAL PILE
10M X 22.359' LG

IS AN INTERIOR NOTES:

TYP. FOR ALL INTERIOR BEAMS


BEAM
@15" o/c TOP

HELICAL PILE - SPACING BETWEEN BARS MUST BE GREATER THAN TWICE BAR DIAMETERS
BOTTOM BAR AS PER DETAILS - CONCRETE COVER TOPAND/OR BOTTOM MUST BE GREATER THAN BAR DIAMETER
3' LAP AT PILE CAPS ONLY - ALL REINFORCING REBARS GRADES ARE 400MPa
DO NOT SPILECE BETWEEN PILES - THESE SPLICES ARE FOR THE TOP/BOTTOM BARS FOR THE SLABS ONLY (NOT THE BEAMS)

TYP. BARS SPLICES - BEAMS


20.359'

A TYP. BARS SPLICES - SLABS


A
10M @ 15" o/c EA. WAY TOP AND BOTTOM.
NTS 1 NTS 2
HOOK TOP BARS DOWN 12" AT PERIMETER.
LAP BARS 16" AND STAGGER LAPS
101

A
10M @ 15" o/c EA. WAY TOP AND BOTTOM.
HOOK TOP BARS DOWN 12" AT PERIMETER.
101

LAP BARS 16" AND STAGGER LAPS


20.917'

(HOOK EA. END DOWN 12")

15M X 22.958' LG
(HOOK EA. END DOWN 12")
@ 15" o/c BOTTOM

@15" o/c TOP


10M X 20.917' LG
10M X 22.917' LG

@15" o/c TOP

C B 15M X 20.958' LG
@ 15" o/c BOTTOM

(HOOK EA. END DOWN 12")

HOOK TOP BARS DOWN 12" AT PERIMETER.


@ 15" o/c BOTTOM

15M @ 15" o/c EA. WAY TOP AND BOTTOM.


15M X 22.750' LG
A

15M X 24.750' LG

LAP BARS 24" AND STAGGER LAPS


NTS

101
3

@15" o/c TOP


101
101
22.750'

101

15M @ 15" o/c EA. WAY TOP AND BOTTOM.


HOOK TOP BARS DOWN 12" AT PERIMETER.
LAP BARS 24" AND STAGGER LAPS

20.958' 2-20M @ 6" O/C TOP


5/8" ø. X 8" BOLTS SPLICE 3' LAP MIDDLE SPAN BETWEEN PILES
10" 2-20M @ 6" O/C TOP
SPLICE 3' LAP MIDDLE SPAN @ CORNERS & 8" C/C
BETWEEN PILES 6" IN FROM PLATE ENDS

10.000'
101 2-10M CLOSED TIES @ 10" O/C (FOR GARAGE SLAB)
2-10M CLOSED TIES @ 10" O/C
6"

10 M HORIZONTAL REBAR 16" O/C 2-10M CLOSED TIES @ 8" O/C )FOR HOUSE SLAB)
HOOK TOP BARS DOWN 12" TYP.

ELEV. = 620.600 M

2" CL
24"

2" CL
L1

L2
L2
8" MIN

12"

3" CL
2" CL

18"
10 M HOOK DOWEL @ 16" O/C
RETAINING WALL

3" CL
TOTAL WIDTH 10" THICKENED SLAB 12" DEEP X 12" WIDE FOR SLABS
KEEP 2" CLR FROM AS FOR ABC BEAM, 18" DEEP X 12" WIDE
EACH SIDE L1 = 8" FOR GARAGE TO FORM INTERNAL GRADE BEAMS

3" CL.
10 M HOOK DOWEL @ 16" O/C = 6" FOR HOUSE
16" 2-20M @ 6" O/C BOTTOM
10 M HORIZONTAL TOP @ 16" O/C
SPILCE 3' LAP L2 = 10" FOR GARAGE
10 M HORIZONTAL BOTT. @ 12" O/D 2-20M @ 6" O/C BOTTOM
= 8" FOR HOUSE
4" PVC DRAINAGE PIPE SPILCE 3' LAP
PERFORATED - HOLES
12"

DOWNWARD - NO 12"
(TYP) MIN 6" THICK LAYER
HIGHER THAN 12" 3/4" CLEAN/WASHED
FROM THE BASEMENT DRAIN STONES FOR
HELICAL PILE 2-7/8" x SCHD 40
FLOOR WATER DRAINAGE
AND RADON REQUIREMENT
10" 10" 48"
EXTERIOR BEAMS INTERIOR BEAMS
SCALE 1:6
101 103
SCALE 1:6
RETAINING WALL
SCALE 1:6

BC FOUNDATIONS & PROVINCIAL HELICAL PILES LTD REVISIONS


2591 PARKCREST AVE. KAMLOOPS, BC V2B 4Y4

04
MM/DD/YY REMARKS
INFO@BCFOUNDATIONS.CA T: 250-377-5417 1 05/04/20 PREPARED AND ISSIED
REBAR/DRAINAGE DETAILS SCALE: VARIES BCFOUNDATIONS.CA & PROVINCIALHP.CA 2 05/14/20 FIRST REVISION (NG)

3 05/20/20 SECOND REVISION (NG)


PROJECT ADDRESS: 680 MONARCH DR.

S
4 06/03/20 THIRD REVISION (NG) - REVISED AS PER DOC. CA3949538
KAMLOOPS, BC 5 _ _ /_ _ /_ _ ...