VERTICAL ANALYSIS Figure 1

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

(with Load Factor)


Vertical Load, Q= 111.2 -kN

Profile:
Pile Length, L= 10.0 -m
Top Height, H= 0.000 -m
Slope Angle, As= 0.0
Batter Angle, Ab= 8.5

Micropile (MiniPile)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MPa -kN/m
0 18.078 33.1 0.000 12.404 35.04 10 0.0 15 54.8 47.1 1301.9 199938 0.420
2.134 20.279 0.0 58.892 82.488 0.88 10 4.6 17 377.4 55.9 5058.7 20683 0.665
4.572 8.677 34.2 0.000 11.563 41.10 13 10.0
6.706 10.988 32.5 54.104 192.281 0.61 18
9.144 9.275 36.5 0.000 18.322 54.06 20

Vertical Capacity:
Weight above Ground= 0.00 Total Weight= 4.16-kN *Soil Weight is not included
Side Resistance (Down)= 358.973-kN Side Resistance (Up)= 358.973-kN
Tip Resistance (Down)= 106.390-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down) Qult= 465.362-kN Total Ultimate Capacity (Up)= 363.136-kN
Total Allowable Capacity (Down) Qallow= 292.510-kN Total Allowable Capacity (Up) Qallow= 183.649-kN
OK! Qallow > Q

Settlement Calculation:
At Q= 111.20-kN Settlement= 0.08009-cm
At Xallow= 2.50-cm Q= 99999.00000-kN

Note: If the program cannot find a result or the result exceeds the upper limit. The result will be displayed as 99999.

CivilTech Micropile with Pressure Grout


Software Two Sections. No Friction on top section