prv240 Manual
Hazardous voltage. removed or the case open. Hazardous LIMITED WARRANTY AND LIMITATION OF LIABILITY
voltage exposure is possible. This Fluke product will be free from defects in material
Battery ●● Repair the Product before use if the and workmanship for one year from the date of purchase.
This warranty does not cover fuses, disposable batteries,
battery leaks. or damage from accident, neglect, misuse, alteration,
Certified by CSA Group to North
American safety standards.
●● Have an approved technician repair the contamination, or abnormal conditions of operation or
Product. handling. Resellers are not authorized to extend any other
Conforms to relevant Australian EMC warranty on Fluke’s behalf. To obtain service during the
To install or replace the batteries: warranty period, contact your nearest Fluke authorized service
standards.
1. Turn the battery-door latch until the unlock center to obtain return authorization information, then send
Conforms to European Union directives. symbol aligns with the arrow. the product to that Service Center with a description of the
problem.
2. Lift off the battery door.
Conforms to relevant South Korean EMC THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
3. Insert or replace the four AA batteries. Use WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR
Standards.
the correct battery orientation. PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
This product complies with the WEEE 4. Install the battery door. LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
Directive marking requirements. The 5. Turn the battery-door latch until the locked CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM
affixed label indicates that you must ANY CAUSE OR THEORY. Since some states or countries
symbol aligns with the arrow. do not allow the exclusion or limitation of an implied warranty
not discard this electrical/electronic or of incidental or consequential damages, this limitation of
product in domestic household waste. Specifications liability may not apply to you.
Product Category: With reference to Output voltage Fluke Corporation Fluke Europe B.V.
the equipment types in the WEEE 240 V ac rms or dc ����������� ±10 % ≥1 MΩ
LoZ >3 k٠load ���������������� 60 V ac typical P.O. Box 9090 P.O. Box 1186
Directive Annex I, this product is classed
50 V ac rms minimum Everett, WA 98206-9090 5602 BD Eindhoven
as category 9 "Monitoring and Control
Instrumentation" product. Do not dispose Output loading ���������������������� See Figure 1 U.S.A. The Netherlands
of this product as unsorted municipal LED power indicator ��������� Turns on when output voltage is
11/99
waste. present
Fluke Corporation certifies this Product was tested and
Battery ����������������������������������� 4 x AA Alkaline batteries NEDA 24 A
Safety verified with applicable calibration procedures during the
Operation IEC LR03 manufacturing process. Fluke’s quality system controls these
Battery life ����������������������������� 5000 (5-second duration) test cycles procedures.
A Warning identifies conditions and procedures Table 2 shows the locations for the controls and with >1 MΩ load, 300 tests minimum The instruments used during the testing and calibration of
that are dangerous to the user. interface of the Product. with >3 kΩ load this Product are traceable to SI units through internationally
Operating temperature ����� -10 °C to +50 °C recognized measurement standards.
Warning Use the Product to verify operation of a test tool at Operating humidity ����������� 0 % to 90 % (0 °C to 35 °C) This document is not a certificate of calibration or traceability.
To prevent possible electrical shock, fire, 240 V ac or 240 V dc. 0 % to 70 % (35 °C to 55 °C) To obtain a certificate of calibration contact the nearest
or personal injury: Fluke service center to process an order to have your
To use: Operating altitude ������������� 2000 m
Product returned for calibration. A nominal fee is charged for
●● Read all safety information before you 1. Select the AC or DC function with the Dimensions ����������������������� 11.7 cm x 7.4 cm x 2.8 cm calibration service.
use the Product. selection switch on the side. (4.6 in x 2.9 in x 1.1 in)
Weight �������������������������������� 0.23 kg (8 oz) includes batteries
●● Carefully read all instructions. 2. Place the red probe of the test tool into the (+)
Safety ��������������������������������� IEC61010-1, IEC61010-2-030
●● Do not alter the Product and use only as terminal and press down firmly.
specified, or the protection supplied by 3. Place the black probe of the test tool into the
the Product can be compromised. (-) terminal and press down firmly. 300
●● Do not touch voltages >30 V ac rms, 4. Make sure the meter reading of the Product is 250
0
PN 4571866 November 2014, Rev. 1, 11/16
Fluke-Direct .com
1K 2K 10 K 100 K 1M 10 M
© 2014-2016 Fluke Corporation. All rights reserved. Load Resistance
Product specifications are subject to change without notice. Figure 1.