●● Examine the case before you use the Table 2.

Overview of PRV240 Electromagnetic Compatibility (EMC)


Product. Look for cracks or missing International �������������������������� IEC 61326-1: Controlled
plastic. Carefully look at the insulation Electromagnetic Environment
around the terminals. 1 CISPR 11: Group 1, Class A

PRV240 ●● Do not use the Product if it is altered or


damaged.
Group 1: Equipment has intentionally generated and/or uses
conductively-coupled radio frequency energy that is necessary
for the internal function of the equipment itself.
Proving Unit ●● Remove the batteries if the Product is
not used for an extended period of time, 4 Class A: Equipment is suitable for use in all establishments
other than domestic and those directly connected to a low-
or if stored in temperatures above 50 °C.
SOURCE ONLY

Instruction Sheet If the batteries are not removed, battery


2 3 voltage power supply network that supplies buildings used
for domestic purposes. There may be potential difficulties in
leakage can damage the Product. ensuring electromagnetic compatibility in other environments
hvj02.eps
Introduction ●● You must close and lock the battery due to conducted and radiated disturbances.
door before you operate the Product. Item Description Caution: This equipment is not intended for use in residential
The PRV240 Proving Unit (the Product) is an environments and may not provide adequate protection to
●● Replace the batteries when the low Voltage selection
electronic voltage source. This Product provides  radio reception in such environments.
battery indicator shows to prevent
a safe, risk free, and easy method to verify proper Emissions that exceed the levels required by CISPR 11 can
incorrect measurements.  + Terminal
operation of a test tool. Use it to verify either an occur when the equipment is connected to a test object.
energized source or a de-energized source. Also Symbols  − Terminal Korea (KCC) ��������������������������� Class A Equipment (Industrial
use it in cases where no known voltage source is Broadcasting & Communication
available to verify a test tool. Symbols used in the instructions or on the Product  Power indicator Equipment)

are shown in Table 1. Class A: Equipment meets requirements for industrial


The Product does not require personal protective Battery Installation/Replacement electromagnetic wave equipment and the seller or user
Table 1. Symbols
equipment (PPE) unless your environment  Warning
should take notice of it. This equipment is intended for use in
requires minimal PPE such as a hard hat, safety business environments and not to be used in homes.
Symbol Definition To prevent possible electrical shock, fire,
glasses, or ear plugs. USA (FCC) ������������������������������ 47 CFR 15 subpart B. This product
Risk of danger. Important information. or personal injury: is considered an exempt device per
 See manual. ●● Do not operate the Product with covers
clause 15.103.

Hazardous voltage. removed or the case open. Hazardous LIMITED WARRANTY AND LIMITATION OF LIABILITY
 voltage exposure is possible. This Fluke product will be free from defects in material
 Battery ●● Repair the Product before use if the and workmanship for one year from the date of purchase.
This warranty does not cover fuses, disposable batteries,
battery leaks. or damage from accident, neglect, misuse, alteration,
Certified by CSA Group to North
 American safety standards.
●● Have an approved technician repair the contamination, or abnormal conditions of operation or
Product. handling. Resellers are not authorized to extend any other
Conforms to relevant Australian EMC warranty on Fluke’s behalf. To obtain service during the
 To install or replace the batteries: warranty period, contact your nearest Fluke authorized service
standards.
1. Turn the battery-door latch until the unlock center to obtain return authorization information, then send
Conforms to European Union directives. symbol aligns with the arrow. the product to that Service Center with a description of the
 problem.
2. Lift off the battery door.
Conforms to relevant South Korean EMC THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
 3. Insert or replace the four AA batteries. Use WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR
Standards.
the correct battery orientation. PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
This product complies with the WEEE 4. Install the battery door. LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
Directive marking requirements. The 5. Turn the battery-door latch until the locked CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM
affixed label indicates that you must ANY CAUSE OR THEORY. Since some states or countries
symbol aligns with the arrow. do not allow the exclusion or limitation of an implied warranty
not discard this electrical/electronic or of incidental or consequential damages, this limitation of
product in domestic household waste. Specifications liability may not apply to you.
Product Category: With reference to Output voltage Fluke Corporation Fluke Europe B.V.
 the equipment types in the WEEE 240 V ac rms or dc ����������� ±10 % ≥1 MΩ
LoZ >3 k٠load ���������������� 60 V ac typical P.O. Box 9090 P.O. Box 1186
Directive Annex I, this product is classed
50 V ac rms minimum Everett, WA 98206-9090 5602 BD Eindhoven
as category 9 "Monitoring and Control
Instrumentation" product. Do not dispose Output loading ���������������������� See Figure 1 U.S.A. The Netherlands
of this product as unsorted municipal LED power indicator ��������� Turns on when output voltage is
11/99
waste. present
Fluke Corporation certifies this Product was tested and
Battery ����������������������������������� 4 x AA Alkaline batteries NEDA 24 A
Safety verified with applicable calibration procedures during the
Operation IEC LR03 manufacturing process. Fluke’s quality system controls these
Battery life ����������������������������� 5000 (5-second duration) test cycles procedures.
A Warning identifies conditions and procedures Table 2 shows the locations for the controls and with >1 MΩ load, 300 tests minimum The instruments used during the testing and calibration of
that are dangerous to the user. interface of the Product. with >3 kΩ load this Product are traceable to SI units through internationally
Operating temperature ����� -10 °C to +50 °C recognized measurement standards.
 Warning Use the Product to verify operation of a test tool at Operating humidity ����������� 0 % to 90 % (0 °C to 35 °C) This document is not a certificate of calibration or traceability.
To prevent possible electrical shock, fire, 240 V ac or 240 V dc. 0 % to 70 % (35 °C to 55 °C) To obtain a certificate of calibration contact the nearest
or personal injury: Fluke service center to process an order to have your
To use: Operating altitude ������������� 2000 m
Product returned for calibration. A nominal fee is charged for
●● Read all safety information before you 1. Select the AC or DC function with the Dimensions ����������������������� 11.7 cm x 7.4 cm x 2.8 cm calibration service.
use the Product. selection switch on the side. (4.6 in x 2.9 in x 1.1 in)
Weight �������������������������������� 0.23 kg (8 oz) includes batteries
●● Carefully read all instructions. 2. Place the red probe of the test tool into the (+)
Safety ��������������������������������� IEC61010-1, IEC61010-2-030
●● Do not alter the Product and use only as terminal and press down firmly.
specified, or the protection supplied by 3. Place the black probe of the test tool into the
the Product can be compromised. (-) terminal and press down firmly. 300

●● Do not touch voltages >30 V ac rms, 4. Make sure the meter reading of the Product is 250

42 V ac peak, or 60 V dc. valid for the test function. 200


●● Do not use the Product around For low impedance test tools, the output voltage
explosive gas, vapor, or in damp or wet should be sourced at >50 V ac or dc. It is
V ac 150

environments. recommended to test both the ac and dc functions 100


●● Do not use the Product if it operates of the test tool.
incorrectly. 50

0
PN 4571866 November 2014, Rev. 1, 11/16

Fluke-Direct .com
1K 2K 10 K 100 K 1M 10 M
© 2014-2016 Fluke Corporation. All rights reserved. Load Resistance
Product specifications are subject to change without notice. Figure 1.