$:10Feot: potentiometer manually given voltage input +,
Potentiometer manually given voltage input -
Foot 11: Automatic Display Switch Input
Foot 12:24,
Foot 13: 24V GND
14.15 Foot: Empty calibration order, Empty calibration indication
16 foot: section selection
17-18 Foot: Full calibration order, Full calibration indication
20.21 Foot :4-20 mA Set level height signal
22.23 Foot :0-10 V Set level height signal
Area 19. s:
+ 25 core standard double-row pins:
3.4,5 feet: Upper limit alarm :NO/ middle contact point / NC
7.8,9 feet: Lower limit alarm :NO/ middle contact point / NC
11.12,13 feet: MEU normal : NO/middle contact point /NC
Area20. 220 V Power outlet
Area 21, Instrument grounding
or receiver);
1. Check MEU display information, data should be like follow:
Ay The N value is big enough
8. VO value 4-8
Cy The V6 value is about v0.5-1
Note: Mean while, the sen: and radioactive source should be fixed tightly in the
mold_and source contait should be_in_epen condition: Mould cooling water
should be full of mould jacket, Not allow other metal stu inside of mould;
2. If the V6 value is not about 0.5-1 V and the N value is small, it is necessary to
Sxecute the peak stabilization operation.:By Pressing "MOD" input "9999" and
Press "1", the peak voltage can be adjusted automatically. (Prohibit in casting) ;
3. ifthe automatic V6 can not be adjusted, it i necessary to execute the manual peak
stabilization operation,