50 HP XP
50 HP XP
Nidec trademarks followed by the ® symbol are registered with the U.S. Patent and Trademark Office.
NIDEC MOTOR CORPORATION
8050 WEST FLORISSANT AVE.
ST. LOUIS, MO 63136
TO:
USE THE DATA PROVIDED BELOW TO SELECT THE APPROPRIATE DIMENSION PRINT
Horsepower 50
Pole(s) 02
Voltage(s) 460-230
Frame Size 326TS
Shaft U Diameter 1.875
Outlet Box AF 3.88
Outlet Box AA 2.00
Nidec trademarks followed by the ® symbol are registered with the U.S. Patent and Trademark Office.
EFFECTIVE:
DIMENSION PRINT PRINT:
18-OCT-13 WITH OVERSIZED OUTLET BOX 07-3095
SUPERSEDES: FRAME: 320TS SHEET:
NEW BASIC TYPE: LC, NC 1 OF 1
C AB
N T
AC
W
P O
AF
U D
ES
K J
AA SIZE
BS CONDUIT G
E
EV
2F BA 2E
H
4 HOLES B A
B D 2E H J K
UNITS A C E ±.03
G N O
-.06 +.05
IN 15.75 15.00 29.19 8.00 6.25 12.50 1.13 .66 3.25 4.65 4.13 16.38
MM 400 381 741 203 159 318 29 17 83 118 105 416
2 U V ES
UNITS P T W AA AB AC AF BA BS MIN
-.001 MIN
IN 16.75 2.03 1.875 3.50 .38 16.13 11.13 3.88 5.25 6.00 2.03
2 NPT
MM 425 52 47.63 89 10 410 283 98 133 152 52
SQ
UNITS EV KEY
IN 1.50 .500
MM 38 12.70
FRAME UNITS 2F
±.03
IN 10.50
324TS
MM 267
IN 12.00
326TS
MM 305
IHP_DP_NMCA (MAR-2011) SOLIDEDGE
1. ALL ROUGH CASTING DIMENSIONS MAY VARY BY .25" 4. STANDARD ASSEMBLY POSITION F-1 IS SHOWN F-2 IS PROVIDED
DUE TO CASTING AND/OR FABRICATION VARIATIONS. WHEN SPECIFIED. CONDUIT OPENINGS MAY BE LOCATED IN
2. LARGEST MOTOR WIDTH. STEPS OF 90 DEGREES REGARDLESS OF LOCATION.
3.TOLERANCES SHOWN ARE IN INCHES ONLY. STANDARD AS SHOWN WITH CONDUIT OPENING DOWN.
07-3095/- ISSUED BY
S. MONTALVO
INFORMATION DISCLOSED ON THIS DOCUMENT APPROVED BY
Nidec Motor Corporation IS CONSIDERED PROPRIETARY AND SHALL NOT BE
J. SALINAS
REPRODUCED OR DISCLOSED WITHOUT WRITTEN
St. Louis, Missouri CONSENT OF NIDEC MOTOR CORPORATION
CATALOG NUMBER: YC50P1BS NAMEPLATE PART #: 422696-001
MODEL FB49 FR 326TS TYPE LCE ENCL TEFC
SHAFT 6311-J/C3 - QTY 1 OPP 6211-J/C3 - QTY 1
END BRG END BRG
PH 3 MAX 40 C ID#
AMB
INSUL F Asm. F1 DUTY CONT
CLASS Pos.
T1
T9 T4
T6 T7
T3 T2
T8 T5
Delta Connection
Lo - Volts Hi - Volts
9 4 7 9 4 7
5 8 6 5 8 6
3 2 1 3 2 1
Line Line
Each lead may have one or more cables comprising that lead.
In such case each cable will be marked with the appropriate lead number.
ITEM ITEM
NO. QTY NAME OF PART NO. QTY NAME OF PART
1 1 Slotted Headless Pipe Plug 22 1 Slotted Headless Pipe Plug
2 1 Pipe Coupling 23 1 Pipe Plug
3 1 Pipe Nipple 24 2 Screw
4 1 Pipe Cap 25 4 Screw (Qty 8 on frames 286T & 326T)
5 1 Pipe Nipple 26 1 Bracket (Not used on types TF)
6 2 Cap and Jam Nut 27 4 Screw (Used only on frame 286T & 326T)
7 1 Fan Cover Guard 28 1 Air Deflector ((Used only on frame 286T & 326T)
8 3 Screw & Lockwasher 29 1 Ball Bearing
9 1 Grill 30 1 Bearing Cap
10 1 Vent Fan Assembly 31 1 Rotor Assembly (Includes items 31A & 31B)
11 1 Woodruff Key (Not used on frames 254T &256T 31A 1 Motor Shaft
12 2 Screw 31B 1 Rotor Core
13 2 Stud & Nut 32 4 Screw
14 2 Screw (Qty 6 on frames 254T & 256T) 33 1 Outlet Box Cover
15 1 Bracket 34 1 Gasket
16 4 Screw (Used only on frame 286T & 326T) 35 4 Screw (Qty 2 on frames 254T & 256T)
17 1 Air Deflector (Used only on frame 286T & 326T) 36 1 Outlet Box Base
18 1 Ball Bearing 37 1 Gasket (Outlet Box Base)
19 1 Bearing Cap 38 1 Eyebolt
20 1 Key
39 1 Wound Stator Assembly
21 1 Water Deflector
WARNING: BEARINGS: PRICES:
Any disassembly or repair work on explosionproof motors will void the Refer to motor nameplate for the bearing Parts stocking distributors: refer to renewal
Underwriters Laboratories, Inc. label unless done by the manufacturer, or a numbers. parts numerical index. All Others: refer to your
facility approved by the Underwriters Laboratories, Inc. Refer to your nearest parts distributor.
nearest sales office for assistance.
reference: Renewal Parts Section 700, Page 19
Copyright © 2010 Nidec Motor Corporation. All rights reserved.
General Information for Integral Horsepower (IHP) Motors
on Variable Frequency Drives (VFDs)
*This information applies only to Integral Horsepower (IHP) motors as defined on the Agency Approval page, under UL®† & CSA®† listings where indicated.
† All marks shown within this document are properties of their respective owners. Revised ─ August 2016
www.usmotors.com vii
Motor / Inverter
Compatibility
Thermal Overloads and Single Phase Motors Multiple Motors on a Single VFD
Motors with thermal overloads installed may not operate properly on a Special considerations are required when multiple motors are powered
VFD. The current carrying thermal overload is designed for sine wave from a single VFD unit. Most VFD manufacturers can provide guidelines
power. Operation on a VFD may cause nuisance tripping or potentially for proper motor thermal considerations and starting/stopping of motors.
not protect the motor as would be expected on line power. Thermostats or Cable runs from the VFD and each motor can create conditions that will
thermistors installed in the motor and connected properly to the VFD may cause extra stress on the motor winding. Filters may be required at the
provide suitable thermal overload protection when operating on a VFD. motor to provide maximum motor life.
(consult codes for installation requirements)
Grounding and Cable Installation Guidelines
Single phase motors and other fractional horsepower ratings are not Proper output winding and grounding practices can be instrumental in
designed to be operated on a VFD. Within Nidec Motor Corporation minimizing motor related failures caused by PWM waveform characteristics
standard products, all motors NEMA®† 48 frame (5.5” diameter) and and installation factors. VFD manufacturers typically provide detailed
smaller are not suitable for VFD applications. Three phase 56 and guidelines on the proper grounding of the motor to the VFD and output
143/145 frame applications should be noted on the catalog price page; cable routing. Cabling manufacturers provide recommended cable types
or if in doubt ask an Nidec Motor Corporation technical representative for for PWM installations and critical information concerning output wiring
recommendations on compatibility with a VFD. impedance and capacitance to ground.
Bearing Protection on Inverter Duty Vertical Motors NEMA®† Application Guide for AC Adjustable Speed Drive Systems:
All U.S. MOTORS® brand “Inverter Duty” vertical products have a shaft http://www.nema.org/stds/acadjustable.cfm#download
grounding system that allows damaging shaft currents a low resistance
path to ground. Bearings on vertical motors fed by VFD power without
this bearing protection are not covered under any warranty. All other
bearing failure is covered per NMC’s standard warranty. An electric motor
repair shop approved to service U.S. MOTORS® brand motors must verify
that the cause of the bearing failure was not due to EDM damage.
* This information applies only to Integral Horsepower (IHP) motors as defined on the Agency Approval page, under UL®† & CSA®† listings where indicated.
† All marks shown within this document are properties of their respective owners. Revised ─ August 2016
viii www.usmotors.com
Warranty Guidelines for Integral Horsepower
(IHP)* Motors on Variable Frequency Drives
Warranty Guidelines Cable distances are for reference only and can be further limited by
The information in the following section refers to the motor and drive hot and humid environments (refer to Table 1). Refer to specific VFD
application guidelines and limitations for warranty. manufacturers cable limits. Refer to the Motor/ Inverter Compatibility page
for special consideration of vertical motor bearings.
* This information applies only to Integral Horsepower (IHP) motors as defined on the Agency Approval page, under UL®† & CSA®† listings where indicated.
† All marks shown within this document are properties of their respective owners. Revised ─ August 2016
www.usmotors.com ix