You are on page 1of 25
AALBORG INDUSTRIES K.K. [File No- 05101051 1/0512/0513, IPNP-__HPS-16 x3 veto ‘Og 991370737 179008267526 AALBORG INDUSTRIES STX Offshore & Shipbuilding Co., Ltd. H. Nos. S-4010/4013/4015/4016 PRIMAVAC SYSTEM Dae Cen 08 AALBORG INDUSTRIES K.K. ORDER MANAGEMENT GROUP zs Teiage —[__checies | aaaroed Iason aora0%8 lexczul toe Coe a ard comments asumzoiel AleY any ‘eran [Sig Apt ‘AALBORG INDUSTRIES KK. 22, 4:Chome, Kumol- don, Telephone #81 78 271 5738 Chuo-ku, Kobe 651-0008 Japan Telefax +81 70.271 5741 PAGE1 8 As six BRIMAVAG SYSTEM offshore & HPS.16 ‘Shipbuilding Co. Lid. eee HuNo.S 4010/16/16 REVISION DATE ATs Te Page| Drawing No. Description 7. DRAWING LIST [25-Jan|28-Ay : 7. SPECIFICATION EEE PNS10878A ‘3. GENERAL ARRANGEMENT 28K 7 PIPING DIAGRAM 2 PNST0870A i PRIMAVAG UNIT ASSEMBLY, HPS-16 PNS10707 PRIMING VALVE ASSEMBLY PNS10636 - CLEANING DEVICE ASSEMBLY HPS-16~26 FOK2IG200WA-AS! | 9. MAIN DISCHARGE VALVE, JIS 16K-400A FOK-221050WA-AS1_| 10, PUMP VENT LINE CHECK VALVE, JIS 10K-50A PN310700, 71. AIR EVACUATION CHEGK VALVE, JIS 16-650 PN:3708808 72, RECIRCULATION TANK WITH SUCTION STRAINER [25 Jan|2B-A PN4109236. 713, PAINTING SPECIFICATION aE 714. DESIGN RECOMMENDATION OF PRIMAVAG SYSTEM, 75, SPARE PARTS AND TOOLS: [memorandum “AIKK- PNP Rev.A Yard comments. 25-Jan-2010 6-Nov-2000]Designed J Rev.B Added 4018/4016, 28-Apr.201 AKY JApproved Mak INDUSTRIES Specification Shipyard: STX Offshore & Shipbuilding Co., Ltd. Hull Nos.: $-4010/13/15/16 Crude / Product Oil Tanker Specification of cargo oil pump .. HCP350, Vertical centrifugal pump 2,000 m’sh x 130 m TH © Number of pump ‘© Height from pump suetion center to impeller eye top, ‘© Effective volume of suction side under impeller eye top level — Note: The above specification was confirmed by pump manufacturer. © Discharge side volume at upstream of Primavac unit: ‘© Suction side volume... oe © Effective design volume of recirculation tank Scope of supply © Primavac unit -HPS-16 x 3 sets/ship JIS16k-400A x 3 sets/ship JIS10k-5OA x 3 sets/ship JIS16k-65 x 3 sets/ship ‘© Recirculation tank with suetion strainer. vw 1200 mm x 3 sets/ship © Main discharge check valve ‘© Pump vent line check valve Air evacuation check valve.... © Spare parts and 1001... oneesnsnnnenens According to the spare parts list Language UK Last printed 10-May-2010 Page 1 <3. of [AIR EVACUATION LINE. PUMP VENT VALVE (STOP & CHECK V,) TANK VENT VALVE LUQUID LEVEL INDICATING VALVE RECIRCULATION TANK WITH 1200 SUCTION STRAINER = sucrow ne / AIR EVACUATION CHECK VALVE, RECIRCULATION LINE PUNP VENT LINE uauip Het35mm LEVEL OF REQUIRED! MAIN DISCHARGE CHECK VALVE, VOLUME OF PRIMING LIQUID IN DISCHARGE. SIDE Vi=1.28 m3, RECIRCULATION VALVE. BUTTERFLY PRIMA-VAC UNIT MODEL HPS~16 PUMP VENT LINE EYE TOP OF aca ) SUCTION SIDE. VOLUME OF PUMP CASING IN SUCTION SIDE V3=0.16 m3 2,000m3/h x 130 mTH VERTICAL CENTRIFUGAL PUMP MODEL HCP350 = Taded 4076 /A016. Merations Drown rer PRIMAVAC SYSTEM Ison ‘SIX Offshore & Shipbuilding Co., Ltd. H.Nos.S~4010/13/15/16 GENERAL ARRANGEMENT [tenn Ne [neuer eee OD PN:310878 PIPE AND FLANGE SIZE Hull 10/4013 /401! 16 wIS 16K—400A \ Main Discharge Check Valve: () ‘JIS16K-400A 008, 65A Air Evacuation Check Valve: @) JIS 16-658 ‘JIS 1OK=50A 10K-! JIS 10K-50A con JIS 16K—150A JIS 10K-65A, 254 Air Vent Assembly: (@) JIS 16K—400A, 25A Oil Level indicate IP rmavac unit (wPs=1 YE JIS 16K—400A JIS 10K-50A From €.0. Tonk REDUCER 300A x 400A JIS 16K-300A MODEL HCP350 2000m3/h x 130TH 450A) Recirculation Tank: JIS 10K=450A 450A JIS 10K—-50A Drain Note: 1.Equipment with @) mork are supplied by AIK. 2. Fellow flange are not supplied by AIK. ‘Description index | bate | Drown ‘Added 4015/4016. A [ae 0) wat QA) EZ 8) @ w 16-033 HOLES(M30 BOLT) JIS16K—400A FLANGE I = i 1] i> C | | 7 i — | | o-| | g -4+—-+—— “ a —— g LA ¥ FLOW 2 LU a 16-933 HOLES(M30 BOLT) 12-025 HOLES(M22 BOLT) JIS16K~150A FLANGE JISTEK-4004 FLANGE JIS16K—3O0A BLANK FLANGE > INSPECTION OPENING FOR | APPROXIMATE WEIGHT : 674 kg. a PRIMING VALVE 12 |BOLT—NUT | 32sets| 24x90 STEEL 11 [GASKET 2 [9406/0321 +3 |NON-ASBESTOS| 10 |COPPER PIPE. 4 |0.0.12.7xt1.6 |COPPER 9 luwon(ame TPE etbow) | @ |ow.t2.793/eneT [eras [HEXAGON SOCKET HEAD BOLT] 6 [wexz0 sussi6 RECIRCULATION LINE _ 7” |SPRING WASHER 16 [una PB or SUS [HEXAGON SOCKET HEAD BOLT| 16 [12x35 sussie | _ 5 [GASKET 2 [676/038 ¢3 __ |Now-ssaesTOs| NOTE 4 |GASKET 2 1216/9154 t1.5 [NBR 3_|SENSING TUBE ADAPTER 2 |BRONZE 1)THE INSIDE SURFACE TO BE COATED WITH PURE~EPOXY MIN.THICKNESS 250 2_|PRIMING VALVE 2 ROME BOSS.) 2)TEST PRESSURE 20 kg/cm2 1 ee BOY Z STEEL Item] Designation [Pcs] Dimension | water article No. Sie 3 PRIMAVAC SYSTEM AK 2009 STX Offshore & Shipbuilding Co., Lid. |" jae) | 06-Nov-2009 H.Nos.S-4010/13/15/16 HPS-16 ve [oa PRIMAVAC UNIT ASSEMBLY Lauciani pa} [Eammciwewncsmmemr | PN:310879 |A WY Wi Wi oa WaT it_[-3 sta AE TFLoF TOT [2 SF Look aT ——— Sn STL T_T otf ste STAINLESS STEELE 3 aT en Te To posae iro aE ema STANCES St. TE TE ST sre RTA ANE fans OE SP pirer AT Trier SMES EEE NET 1 Cae or AAA BRTE arian os ee | wes - . Tame a 3 RR eR milo ES a [eel es oe 5” PRIMING VALVE ASSEMBLY __} Te OS) aaasegesarae =| Patent FoR sia | Ls PRIMAVAC UNIT i ‘AALBORG INDUSTRIES 1K Pr PN-310797 fi G27 en Sete ‘Description in den Date Drawa] Appr. rik wn [ee [ies [irom [rem [reas Ser eet 2sers | sets | 4 sets | 4 sets | 5 sers NOTES : 1. USE HOT MATER FOR CLEANING GUATER TEXP, TO BE EC ~ sOt), 2, “WOLREO'D" IN THE BELO TABLE SHOAS THE NBER OF PARTS PER OFPET VALE (I FOR THE ‘APPLY SEAL TAPE TO THREADED PARTS BEFORE THEY me ay ra ex me WT, Se TH OTE TL SURED, (Qow'T JPL SEAL TAFE TO THE SORNS OW THE OPPER PIPE SIDE OF OS. 0 2 AND AO. 4), 111 JHOSE(YARD SUPPLY) =Tz RUBBER [us KeI52 10 [SPRING RETAINER = = 9 [ROSE COUPLING RREEe | [sus316 _|JONT FoR Hose| 8 _|(NORWAL fOKg/emna) PLUG_[_1_|PTI72, sussi6 7_|STOP VALVE(20kg/em) Ten/2eni72__[e 6 [NIPPLE 1 [pri/2pn/2_— le 5 [poss 1 |pri/2rti/2 fe 4 [Bree JON 1 |Pri/2,e0.52 [x (SFE) 3 [Pre 1 foo. ssaxtt 2_[Bme—TYPE JONT 1 [9.52 o i) + [808s WiTH NOZZLE 0 sussi6 tera ion Pes.| Dimension ticle No. PRIMAVAC SYSTEM CLEANING DEVICE ASSEMBLY HPS-16 ~ 26 PN:310836, s-ov-2005| put [ae teas [Sater — | = a3 Peta orig not SIZE oD L od adi 200 280 127 200 219 250 353 | 146 | 250 | 273 |__300 403 | 181 | 300 | 304 . |__350 447 | 184 | 350 355 ra 400 507 | 190 | 400 | 406 4 L450 572_| 203 | 450 | 457 a5 o— INSTALLATION ots ott a eens e fo fom FLAP_CHECK V/V WAFER ae ae (a rE en er [ea sae eee sou as fee seonoN_AcA BSe cree AeA, ote] [ove no [ro TROT [DW CDONG—A VALVE Ha eS 7 " m REVISION SIZE 9D L od | dt QTY | RMK’S atte ERE “50 101 | 60 | 50 | 60 65 121 67 65 73 a 80 131 [| 73 | 80 | 89 100 156 | 73 | 100 | 114 125 137 [| 86 | 125 | 141 cL 150 2i7_| 98 | 150 | 168 + 200 267_| 127| 200 | 219 rie ®—__4 =e INSTALLATION. i z | g Hi 6 fom 7 0 > |__| rae ear ees 3 2 at © fue seme fea [2 G else Teste alr a — | a FLAP CHECK V/V gp [oa [aera a aceon [eos [someone O1SC_OPENING AREA vs. wer APPROKSNATE WELGHT 90 L.8._(14 TRG aT. Se r= HeEXAGCR EAT BOLT STEEL S/Arat xd 7 SELF LOOKING AUT STAINLESS STEEL_9/8"=244NE=04 GASKET ROWASGESTOS 00 5 (/a"x10 79 IE SPRING TAGONEL WORE TA 0, GEM OTA D. Tea? 1/4" CERT Sen te RETATRER STAUNLESS_STEEL TYPE 316 POPPE STAINLESS STEEL_TVPE-17-API ‘SEAT ‘STAINLESS-STEEL TYPE 17-4PH OUTLET Boo CAST STEEL CSTW A2iC WO) LET 007, TEAST STEEL_(ASTHAZTO WEB) enon twist] ie oe we | tae ‘AIR EVACUATION CHECK VALVE eegatuagematoame| ARLBORG INOUSTRIES. RK 227 FLEX. TACT JIS 16K FLANGES 2610 Description Index | Date | Drawn] Appr. The position of flange changed by yard comments. A [s-w-ano] Aky [| MaF Added 4015/4016. B a0 ay [| 2 (200, ea SUCTION tao SUCTION ale vor v 1) eae eee eee eet g g 4-919 HOLES = i re] }—t 8 80_| 840 80 1000 JIS 10K~65A AIR EVACUATION LINE a gl be 5 ; LO A 12 JIS 10K—150A soit anea RECIRCULATION LINE PUMP CONNECTION a IS 10K~450A UNE ; Pcp240 | | _25A LEVEL INDICATING 7 | gt | —|—4 i R g 3 wy 8-623 HOLES | pt | 2 o gs 3 = 3 |_ 30 8 5 = 8) “W BASE LINE I HYDRAULIC TE Hs gi JIS 10K-50A a ie 16 i DRAIN LINE. $819. HOLES. a 600 : | BOLTS,NUTS AND PACKING LIST — Title: [Brawn ss [pote No [ DESCRIPTION | MATERIAL DIMENSION Pes_| PRIMAVAC SYSTEM AkY \3/06-Nov-2009 1_| BOLTS & NUTS | SS400 [ M36x140L Beets : eee eee fier as [Bake 2 | BOLTS & NUTS 1Ss400 [16x50 B sets STX Offshore & Shipbuilding Co., Ltd. Mof?:") | 06-Nov-2009 3 | BOLTS & NUTS | S400 [wiexsoL 8 sets H.Nos.S—4010/13/15/16 91200 aaa nn 7 4_| PACKING NON-ASBESTOS | 0.0.1344x1.0.1230xt3| 1 set AALBORG | RECIRCULATION TANK WITH SUCTION STRAINER =: a io Lo 5_| PACKING NON-ASBESTOS | 0.0.126n.0.35xt3__[2sets_| INDUSTRIES |. ncacamacanamoncmoumo wom f 6_| PACKING NON=ASBESTOS | 0.0.125x1.0.35xt3_| 2 sets x ust wo a ED BY oF REPROELED FORTH PARTY PN:310880 |B —13— Description. Index | Date | Drown] Appr. Corrected internal paint color. A_[é-1m-2010] AkY_[ Mor Added 4015/4016. B__[ay-onfaryy [( Biel, Va) INSIDE SURFACE OUTSIDE SURFACE EPOXY COATING INTERNATIONAL PAINT: TOTAL FILM THICKNESS 2-COATS AVERAGE 250x AT DRY BASE intel (406/403) INTERNATIONAL PAINT ! PRIMAVAC UNIT | INTERNATIONAL platen 1. THA700/703 (PINK) ~125e 125 p.,| 2-EM SERIES 2. THA702/705 (GREY)~1254) ‘he 3900) 126 MAIN DISCHARGE CHECK VALVE DITTO a PUMP AIR VENT CHECK VALVE DITTO a AIR EVACUATION CHECK VALVE DITTO a RECIRCULATION TAN oITTO DITTO Title: fawn (SH \ [bate PRIMAVAC SYSTEM [AK | 06-Nov-2000 / STX Offshore & Shipbuilding Co., Ltd. |” of) | 06-Nov-2009 i ; = 46 [Wear Sealer [Sis adldddiig._|-Nos. 8-4010/13/15/16 Hrs-16 PAINTING SPECIFICATION claro fa NDUSTRIES NOUSTEIES [isumomustamsearmene === | PN:410323 |B AALI INDUSTRIES Design recommendation of PRIMAVAC system Requested arrangement of discharge pipe for V1 Discharge pipe for V1 Discharge pipe for VI _-Pritning volume Vi Figure 1 Discharge pipe for V1 should be as ‘The above arrangement is ideal but is difficult to employ in many cases especially in ‘medium or large sized tankers because of the height restriction of the floor. ‘Language UK Page 1 of 6 Last printed 06-November-2009 AALBORG INDUSTRIES ‘The below arrangement is permissible: DL : Total length of V1 ibe [Ey : Length of horizontal portion ms zi Ifthe arrangement in the fiuro ie st eeu, pox contact ALBORG INDUSTRIES KK. Figure 2 2 Requested diameter of stripping bellmouth line 4 XX (m?)x S(am/sec) Pumpratedcapacity(m'sh) X—1_. (/sec) 3600 030 4d: diameter (m) of stripping bellmouth line If a 1,000 m’/h is considered, the inside diameter of stripping bellmouth line is calculated at 0.146 meter. The diameter is decided to be 150A or 200A. [Language UK Page 2 of 6 Last printed 06-November-2009 AALBORG INDUSTRIES of PRIMAVAC system. = 7 ai S80) 380 NO — AOLaNG 8 OL SK ANA BLVD Yo SATA HEALD (om) — - rel a x= — / PIES sou sy aes 99 / EY » (MOTEE_NAOHS SV GuVAdN OVI 94 OL ST THAINAA / SCN JT OL Fav Sadid SSanT ‘HL SOTSHI SAN sO SNINGAO ONISNGS SLL) ATWOLMA # ©, ‘GTIVISNT GH OF ST LIN SvAWRTA NOMORITG MOTE LORD HOTA» + ATWOUMAA JAS 3A OL ST LaviS EWA LHL AVA HOMS RE ¢ ATIVIMOZTON » + SATA dOLS ¥ SNIGIAGUd INOHETM SATVA YOGI) TWIN 3 0 soyniiele'hion att Gh Selina Neue a sua iol GREY UA aid BOMADSTC STL OL Bard MBRLONY LANDS WaAAN NOLISBTG MOM L9ANMOD SHE HLTA ATA, YORKD BOUVHOSTA NIH BHL OL ATHTSSDA SV 480 SV 4 # ATIWINOZTUOH # any oenamsa on / row sowisid GES MY © = ATWOLLDA © + / TEIN Ol 0 ars aD SMOSIT NI CSTV SE OF SY aN WSN NOTIN HIV Figure 3 Page 3 0f 6 Language UK. Last printed 06-November-2009 ails AALBORG INDUSTRIES Proper installation of PRIMAVAC system In order to make PRIMAVAC system properly function, shipyards are requested to meet the below itemized requirements when making the pump room arrangement. 3.1 Discharge side volume at upstream of PRIMAVAC unit (V1) So as to secure |L.28 | m*s:1% as discharge side priming volume (V1), calculate the pipe length based on the pipe inner diameter. Discharge side priming volume (V1) means the pipe inner volume between PRIMAVAC unit and main discharge check valve which is shadowed on general arrangement drawing. If a short pipe is inserted between recirculation tank outlet flange and cargo oil pump inlet flange, the volume equal to the volume inside this short pipe should be added to the above volume (V1). 3.2 Suction side volume (V2) ‘So as to secure the suction side volume (V2), follow the below instruction. © When calculation is made in the volume calculation sheet of the drawing on the assumption that recirculation tank outlet flange is directly connected with cargo oil pump inlet flange, never fail to direcily connect recirculation tank outlet flange and cargo oil pump inlet flange. © When calculation is made in the sheet on the assumption that a short pipe is inserted between recirculation tank outlet flange and cargo oil pump inlet flange, made the length of the short pipe within =] mm:1%. 3.3 PRIMAVAC unit ‘The PRIMAVAC unit should be installed as follows. ‘© Onavertical piping. ‘* On as low a position as possible (a 90° elbow is most suitable for connection between cargo oil pump outlet flange and PRIMAVAC unit inlet flange). + The liquid flow will not be disturbed. 3.4 Main discharge check valve ‘The main discharge check valve should be installed as follows, © Ona vertical piping. * On the position which is determined by section 3.1. Language UK Page 4 of 6 Last printed 06-November-2009 AALBORG INDUSTRIES 3.5 Air evacuation check valve 3.7 Discharge side piping at upstream of PRIMAVAC unit The air evacuation check valve should be installed as follows. © Onahorizontal piping. '* Ona position as near to main discharge check valve as possible. ‘* The air will flow ftom recirculation tank to discharge pipe. To be check correct flow direction. 3.6 Pump vent line check valve ‘The pump vent line check valve should be installed as follows. © Ona horizontal piping. ‘©The valve shaft should be installed vertically with correct flow direction. © The air will flow from pump to discharge pipe Discharge piping (from PRIMAVAC unit outlet to Main discharge check valve inlet) should be installed as follows. © The piping should be vertical as possible. ‘Ian enlarged pipe (like a tank) is employed in he middle of the discharge pipe, the level difference between PRIMAVAC unit outlet and Main discharge check valve will be more than $ meters. © The discharge side volume (V1) of section 3.1 will be secured. ‘© The air trap or disturbed flow will not be produced. ‘© The any branch pipe will not be taken from the main pipe. 3.8 Recirculation line Recirculation line should be installed as follows. ‘+ twill be as straight as possible. (The distance will be shortest). © The liquid will not be trapped. © A butterfly valve or gate valve is to be PRIMAVAC unit on the recirculation line. alled on @ position near to 3.9 Air evacuation line Air evacuation line should be installed as follows. © twill be as straight as possible. (The distance will be shortest) ‘© The liquid will not be trapped. Air evacuation line is to be connected with the discharge pipe as near to Main discharge check valve as possible. Language UK Page 5 of 6 Last printed 06-November-2009 ails AALBORG INDUSTRIES 3.10 Pump vent line Pump vent line should be installed as follows. '* The branch pipe is to be connected with air evacuation line. '* A stop valve should be installed. # A check valve of approx. 0.01 kg/cm? opening pressure (The liquid will flow from the pump to the air evacuation line, and on a horizontal piping.) 3.11 Suction bellmoutt the cargo tank Suitable consideration is to be given, © Oil will be easily gathered to the bellmouth in the cargo hold during unloading ‘* Disturbed flow or eddy will not be produced in the vicinity of the bellmouth uring unloading. “Language UK. Page 6 of 6 Last printed 06-November-2009 SPARE PAGE 20 PRIMAVAC SYSTEM SHIP No. | _S~4010/13 SPARE PARTS AND TOOLS BOX BOX No. -- SUPPLY | ppaWiNG No, NAME SKETCH MATERIAL Wane arr] REMARKS ING PARE| No. No. ISPARE PARTS SSS Ze 88400 1 Fov02 erm 1 | SPARE PARTS BOX fad Ca 59-30 it 89 Is—4010/13 AALBORG INDUSTRIES K.K. MFR’S NAME OS OE 42s MANGO es = TELEPHONE (078) 271-5736 (Int. +81 78 271 5736) & ADDRESS TELEFAX, yaa (nt. $81 78.271 vay anata tint 31 SPARE PAGE 21 PRIMAVAG SYSTEM see aeeeerie nese PRIMAVAG UNIT _(6” TYPE PRIMAVAG VALVE) BOX NO. 1 paesnie | DRAWING NO. NAME SKETCH WATERLAL REMARKS rma {spare | NO. | PART 1 | PRIMAVAG VALVE 6] 2 _ | 13.8 ke COMPLETE /\set 2.| BUSHING prone | 6| 4 4| Me /4pos 306 g 3] RETAINER RING sussis. | 6| 4 6 | Fs Be 4] O-RING SEAL virow | 6] 4 ie 0.75 Ke 5 | SPRING Ts S = vy 6 | SELF LockiNe games | 12 | 4 10] 5 sas 0 ¢ 7| PISTON RING tertoy | 18 | 12 1 i ees Oe 8 | O-RING VITON 18 | 12 12 /\2pes _ | 160 ¢ 9 | GASKET vit =| 6] 4 poe HEXAGON SOCKET 900 10} HEAD BOLT sussig | 48 | 16 - ‘Népos MFR'S NAME SR ae ak“ & ADDRESS AALBORG INDUSTRIES K. K. ftw gai. 7 en SPARE PAGE 22 ‘SHIP NO. $-4010/13 PRIMAVAC UNIT _(6” TYPE PRINAVAC VALVE) BOX NO. 1 serait | DRAWING ‘NO. NAME SKETCH MATERIAL REMARKS. Wome |goane | no. | PART 11 | SPRING WASHER ®. °B wii} 2] -|% a i pos 3 a = MER’ S NAME Se od“ @ appress | AALBORG INDUSTRIES K.K. team gy att fe. 0 ang TOOL PAGE 23 PRINAVAG SYSTEM ——SCSC=*;i SPW. | S-40 10/13 RIMAVAC UNIT _(6” c W BOX NO. ' per sip | DRAWING ‘NO. NAME SKETCH WATERIAL REMARKS Wome epane| no. | PART 1 | HEXAGON WRENCH SO 9 1 540 £/Ip0 2.| SPANNER ser 1 540 ¢/I90 3| L-TOoL 8s 1 500 @/po 4| FLEXIBLE HOSE RUBBER 1 MFR'S NAME Brenan eal iE aoRese AALBORG INDUSTRIES K. K. jaune gain a 1 1 sum SPARE PAGE 24 PR MA\ AC SYS EM. ‘SHIP NO. S-4010/13 6K-400A MAIN CHECK VALVE BOX NO. 1 paeenie | DRAWING ‘NO. NAME SKETCH MATERIAL fron _ REMARKS fing [SPARE] NO. | PAS" 1 | HING PIN fas sss | 3 | 1 4 | me poe ie 8 1650 g 2 | STOP PIN fd | sussig | 3] 1 5 = SE] /\poo co aT] oe 380 3 | SPRING Mpeg yf se [6 2] 1 | 6 | ha S ; Hi z We 4 | B-LUG BEARING (ya | | |ere | 6] 2 z a g 4 i We 5 | P-LUG BEARING Grech pre | 6 | 2 9 pa rm We 6 | s-LU6 BEARING Gail me | 6 | 2 gfe i 7 | CENTER BEARING q pre | 3] 4 7/58 3 1 Nove 8 9 10 WR’ S. NAME SR ae ok GADDRESS AALBORG INDUSTRIES K.K. ieee ap irs. a8 SPARE PAGE 25 PRIMAVAC SYSTEM sip no, | $-4010/13 ——10K-50A PUMP VENT CHECK VALVE ____—_‘| BOX No. 1 DRAWING NO. NAME REMARKS No. | PART u pee j poe 2 2 3 | SPRING % z 36 ; La = |%] ste 7 8 ty s 4 | B+LUG BEARING (oya 4 3 10 tite 5 | P-LUG BEARING g | o48 2008 6 | $-LUG BEARING g | ote /2p0s MFR’ S. MFR'S WANE | AALBORG INDUSTRIES K. K. MEME up BER Ak oN RH RRS

You might also like