You are on page 1of 31
S-type Separation System i aaa Parameter List 7 Printed «Sap 2008 Bock Me, sevesTaeav 12 Contents 1 Parameter Setting tion Parameters Process Parameters Factory Set Parameters ap orn Sequence Diagram 5.1 Separation Sequence. 4 24 181057202 AMETER SETTING 3 SEPARATION SYSTEM PARAL 1 Parameter Setting The parameters are set in the operator panel for the different separator systems, and for different conditions within the systems. ‘There are three parameter types: Installation, Process, and Factory Set parameters. The parameters are initially set at installation. The process parameters can also be set as required during operation, Parameters not in use are not displayed. ‘The parameter list in this booklet is valid for Separation Units (SU) and SA systems. General principle The ‘ENTER’ button is used to: enter into @ parameter list ~ enter into a parameter — accepiistore a new parameter value. ‘The‘¥’ or the ~’ buttons are used to change the value flashing in the display window. 2 1810572-02 To change parameters, proceed as follows: 4 Push the ‘ENTER’ button, ‘Time to discharge P1 60" is shown. 'P1 is the parameter, and '60' is the sei value. The ‘1’ of the ‘Pt’ is flashing. 2 Push the “+ bution until the number of the parameter you wish to program appears in the display window, The chosen parameter number is now flashing 3 Push the ‘ENTER’ button. The chosen parameter number is now shown on the let side in the display. The parameter value is shown flashing on the right side of the display. ‘Schematis diagram with postion LEDs Display window -push> 4 push- Enter bution button push. Button 181057202 1 PARAMETE Push the ‘+’ or ~’ button to change the parameter value, Push the ‘ENTER’ button. The new value is stored, The parameter number is now flashing Push the ‘+’ or ~ button to go to the next parameter to be changed. To leave the list, push the ‘+’ and the * buttons at the same time. The display shows ‘Standst.’ of, when in operation, the trigger value to the left, and time remaining to discharge on the right. LeDterheater (green) 7 Heater onfoff { push-button LED for contro! [program running ‘green) Control program onlotf push-outton LED for stop sequence running (yellow) Sludge discharge push- ution Alarm reset LED for commen LED showing ‘main alarm (red) this pane! active 1 PARAMETER SETTING S-TYPE SEPARATION SYSTEM PARAMETER Li The following lists are available for viewing from a menu in the EPC-50 control unit: * Install (parameters) + Factory (parameters) + Alarms + Test For detailed information see each list. To open the menu and select a list, proceed as follows: 1 Push the ‘ENTER’ button. The process parameter list is now open. 2 Push the +’ button until ‘End is displayed, 3 Push the ‘ENTER’ button and the ‘+’ bution at the same time. ‘Install’ will show flashing on the display. 4 Use the +’ button to select a list. & Use the ‘Enter’ button to enter into the selected list 6 Toleave the list, push the +’ and the buttons at the same time, 7 Toleave the menu, press the ‘+! button repeatedly until ‘Exit’ is displayed. Push the “ENTER' button. 4 1810572-02 8 2 Installation Parameters The installation parameters must be set before the initial start-up and before process parameters are set. These parameters rarely need to be adjusted again, If a new parameter value is to be stored, it is necessary to go through the whole list, and confirm at the end nore Lue ‘Aa Laval caso be held response for injuries So eappaecned oy mages peeaceer anes ‘Se ciel rade ar iee ear acer sot by Alfa Laval. Parameter | Factory set Range Description it n ‘en = English Language, Allinformation displayed Se ‘on the operators panel is shown in the selected language, t= falian pt-= Portuguese fi= Finnish 0 = Swedish Ina Aleap ‘Aloap ‘Separator type Ing 296 211,816 ‘Separator size 200, 820, 821, 825,826 Parameters depending on separator 1300, 830.831, 235,206 «S28 a18 Set automaticaly according tothe value in Ind 409, 840, 841, 845, 848 500, 850, 887, 865, 856 1600, 860, 861, 865, 866 700, 870, 871, 875, 875 1800, 880, 881, 885, 886 Ins 1 1-9 ‘Separator identity lf more than one EPC on more than one separator system is ‘same Sattbus connected to the internal Sattbus communication, each system must bbe given its own identity (1 or 2.0r 3 etc), 1810872-02 5 2 INSTALLATION PARAM SEPARATION SYSTEM PARAMETER LIST “Parameter Factory set Plant set Range Description : : . en —s % ‘Steam (steam heater) into 6 7,8, 14,16, 22, 24, 96,40, El heater size 50, $6, 65, 72, 86,96, 98, activated when El. is selected in 100, 110, 112, 126,128, ing 130, 144 kw n20 120 (0-999 seconds ‘Steam-valve run time ‘Activated when Steam is selected in inte 6 1810572-02 s PARATI 2 INSTALLATION PARAMETERS Parameter | Factory set Plantset | Range Description value value ine 6 (= 80 seconds Alarm delay imme in23 6 0-240 seconds CCharige-over valve V1 temp. alarm delay Prevents false alarm due to any fluctuations in temperature caused by valve actions. nae No No (Change-over valve V1 action at extra Aca alarm | When the extra alarm inputs used, action at alarm can be none (No) or “The feed flow measurement, based ‘on inletpressure, can be displayed in cone of these ways. feed off (es) | n25 Yes No Power fil alarm used Yes I this alarm isnot required, set the parameter to'No* nas No. No “Type of computer communication ExiPC = Fiokibus a naz ° 0-256 Intemet IP adress, part 1 nae ° 0-256 Intemet IP adress, part 2 in29 ° 0-256 Intemet IP adress, part n30 ° 0-288 Intemet IP address, part 4 Inst No No Feed pump controlled Yes Feed pump has to be connected by EPC when running in auto mode. nse mh mth Flow rate in mh per hour or sam US gallons per hour 1810572-02 7 3 Process Parameters ‘The process parameters can be adjusted easily and as often as required, even during operation, to meet changes in the operating conditions, e.g. Lime between sludge discharges, oil temperature, alarm points (vee Regularly check the condition of the bowl. If there is no noticeable amount of hard sludge in the sludge ‘space, the discharge intorval may be increased by 30, minutes at a time. The total discharge interval must not exceed three times the factory set value in order to avoid an uneven build-up of sludge PARAMETER LIST rameter | Factory set Range value Pri 120 71= 300 minutes: Time to discharge Pr2 HF 360 MDO = Marine Diesel Ol ——Ciltype GO =Gas oi) Fax = Intermediate Fuel Oil (ox represents viscosity in Cst at Hic = Heavy Fuel Oil 50°C) LO TP = Lubricating Oil for Trunk Piston Engines LOCH = Lubricating Oil for Gross Head Engines, Pra OP loo: (OPloe = Local OP in control Control locaton (OPrem = Remote OP (Pleo is standard. OPrem, ExtPC Rifts pane ig ‘and FlamSW are shown only when Sa installed, ExtPC = Extern Computer Board FlemSw = Remots switches Pra on On ‘Alcap On/Standoy ste MT50 function disabled when in standby (Sth). Discharge every 18 ‘minutes (overrides Prt). No leplacement water added prs 00 0.0 =Notused ‘Countdown service timer 0.1 t0 10.0x1000 hours ‘Acton is to be taken when the timer reaches 0. 1810572-02 1 SEPARATION STEM PARAMETER UST Parameter Factory set Plantset Range Description value value Pre ° O= service tine lapsed Type of eervce 1-92 Servce text 1..9 When service timer PrS reaches 0, analarmie given and a meseage shown Pr? ° Information Keys to special functions used by 1 = timers shown cee es When P17 is set to 1 during normal operation, the actual timer is splayed if the sutton i pressed once. Pr 10 3.0 0.0~80bar High cil pressure limit Gos olpressure sensor (cleaned oll outa) disabled Prt 10 0.0-60bar Low oil pressure iit Priz 55 0.0-60bar High water prossure lit 20 water (water outer) disabled Pris 02 0.0-60bar Low water pressure limit Prag 30 0.0-60ber High feed pressure limit 0.0 = feed pressure sensor disabled Pets 020 000-600 bar Low feed pressure it Low pressure indicates insufcient flow. The low pressure mit must be higher than any static pressure and lower than normal pressure. Pre 105°C 0-115 Cor HFOILO high temp. iit 0-255°F 0 = Temp sensor disabled Pra as 0-118 Cor HFOILO low temp. lint 0-255°F 1810872-02 PARAMETERS S-TYPE SEPARATION SYS! Parameter Factory set Plant set Range Description | jue value Pris 95°C 0-110 °C or HFOLO setpoint”? 0-240°F Setpoint for feed temperature i valid OaTemp sensorcisabled only whenatomperature controls instalag inthe EPC. Prt9 40°c 0-118 °Cor 0 bigh temp mit 0-255 °F Pr20 20°¢ 0-118 *Cor 0 tow temp. init | 0-255 °F | Prat 30°C 0-110 °C or DO setpoint”? | 0-240 Setpoint rte temperatures vad | only when a temperature controler is installed inthe EPC. | Pra 40 10-50% P-eonstant? | Prose value based on experience | wi Alfa Laval Heatpac heaters | Pr2a 12 01-100 minutes L-eonstant!? | Pieeaiscioe feed ener | wih Afa Laval Heatpac heaters, | Pras ° o-9 Heater contel location 0 = daabled ‘To be set whan more than one EPC | temperature contolarcan be used | forone heater Pras 2 0240 seconds Sludge tank alarm delay (uring Ti 63) Prag 60 0-100 discharges ‘Test of sludge in boat Prat 18 0-100% Max. decrease of displacement water ') Parameter appears only when heater board installed. 10 181057202 RY SET 4 Factory Set Parameters Fa21 Fa22 Fa23 meter Factory set value See tabla on page 02 See table on page ‘See table on page 300 ‘See table on page ‘See table on page os 3.0 if Pr2= fuel oll 06 Pr2= lube cil 100 100 1Oi#Pr2 = fuel of eS#Pr2=TPLO eit Pr2.=CHLO ‘Piant set Range value 0.1 98,99 lie 00-9bar (0 14000 rpm (0 sensor disabled Is set depending on ‘separator size 0 ~ 14000 rpm Is set depending on ‘separator size | 02000 1pm 00-25 (0.0 = sensor disabled 00-25 | 00-25 | 001-1009 0- 250% 0- 250% 0- 999.9 pF (= water transducer disabied 1810872-02 Description ‘Conditioning water volume to be fed after discharge PTS pressure increase or decrease, (Test during 7159, Ti 64, T170, Ti71 Ti 2) Signal thatthe bow! is filed High speed Low speed ‘Speed decrease during discharge Shutdown limit for separator spindle amplitude Vibration alarm prewarning ‘Vibration sensor adjustment zero point. Zero point should be within 152Fa18 Alcap trigger factor This is the amplification factor for the transducer signal co thatthe proper {rigger range is achieved. “Tiager limit HO “Tigger limit LODO ‘Alarm limit for high water transducer value. "1 4 FACTORY SET PARAMETERS PARATION SYSTEM PARAMETER LIST Parameter Factoryset Plant set | Range Description value value [raze | 70 (0-999.9 pF ‘Alarm limit for low water transducer value Fa25 25 (0-250 seconds Pulse time for open drain valve Fa26 5 0-30 seconds Drain pause time. With the valve closed, the system wats for the result of the draining, Fa27 70 0 100% The limit below which the trigger value must be to interrupt draining. Fa26 6 0-20 Limit for number of HFO drainings. It the trigger value has not fallen below the value of Fa 27 after Fa 28, an | slam is given Fao 5 0-40 | Test of water transducer tigger | o=elsabled | signal every x T75Paussard discharge feedback 7 Discharge L__J 30 1810572-02 PATION SYSTEM PARAMETER LIST 5 SEQUENCE DIAGRAM st ‘Start Without ae ee, Calibration UST Faed [iraFeecor speed, ana tap | chock [raevirne] ¥ | sew Hesterot TiSS Standby. Ti6s Yes L Push Seperation intruptedby 1 toeomne Granny? a fushing Ti 60 Discharge | Vv [T8 Sep. motor TT DSEL ot Crack water check cecresang tena] Tr6t Pause | ! Ee Tiss Check a2 Bow cosa Displacement eR y Ti 73 Water 7 FresConcnioing water cule sting. | Tae Tet Feod en 7a tage Y Tie Wing fr 7 O-speed TEMES reise signal test, discharge Y teodback ss (Tera) etd stat y Tey NTE he y Ties Time to discharge Y Ties elapsed? Tie2 Yes [Discharge q_¥ 1810572-02 31

You might also like