You are on page 1of 1

N N

KINGDOM OF
SAUDI ARABIA
W E
E MAK
KAH

S
W KAH
MA
K SITE LOCATION
S

KS

KINGDOM OF BAHRAIN

GENERAL NOTES
NEW S
HADE ROAD BLOCKERS
1. DO NOT SCALE FROM THE DRAWINGS.
2. ALL DIMENSIONS AND LEVELS ARE IN MILLIMETERS UNLESS
SECURITY & SAFETY
NOTED OTHERWISE.

10
BOLLARDS

TO
00
50

CER

BA
1

6.00

TR ROOM
002

LV ROOM
001

11 CAT EY
AM

HR
CER
3. ALL MEASUREMENTS MUST BE CHECKED AND VERIFIED AT SITE

IC

AIN
MA
AM
2 CAT EY

RK
IC

12
ES

S
M

TO
AR
00

KS
KS
55

3
ES

A
13

66 PRO
10

003
GEN. ROOM
ME CE
BY THE CONTRACTOR AND NOTIFICATION TO BE MADE TO THE

5
4

TE DU
29
14

R S RE
98
85

FR CA
0
5

OM B
CER5

60

75 PRO
1

FIRIN
AM

ME C
IC

ST
CA

TE EDU
ENGINEER BEFORE COMMENCEMENT OF THE WORK IN THE

MA
6

RS R
16
EY

R
KS

FR E C
CER

ES

OM AB
AM
7 CAT EY

CHILLER YARD
006

FI IN
IC

RS
MA

T
R
KS
ES
8
EVENT OF ANY DISCREPANCIES ARISING FROM THE DRAWINGS.

9
2
71
15

4. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH OTHER


RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL,

MECM. PUMP ROOM


005

FIRE FIGHTING PUMP ROOM


004

ELECTRICAL AND CIVIL DRAWINGS AND ALL RELEVANT SECTIONS

To ah
IN

B
OUT

1.50
SECURITY & SAFETY
EXISTING BOLLARDS
OF THE SPECIFICATIONS.

ra
5. CONTRACTOR SHALL SUBMIT MATERIAL SUBMITTALS (INCLUDING

in
SECURITY & SAFETY
BOLLARDS MATCHING
WITH EXISTING

TO
KS
A
ROAD BLOCKERS
ALL ACCESSORIES) FOR ENGINEER'S REVIEW AND APPROVAL.
6. CONTRACTOR SHALL SUBMIT FULLY-DETAILED COORDINATED

1.5
0
OM BIN
S FR CA
ER RE
MET CEDU
53 O SECURITY & SAFETY
T PR
FIRS BOLLARDS MATCHING

AIN
WITH EXISTING
22

21

20

19
18

17
01

02
03

04

05
JAN. RM.
CMU WALL

SHOP DRAWINGS FOR ENGINEER'S REVIEW AND APPROVAL,

SPL-1001
HR
16 06

BA
15 07
14 08

13 09

TO 12 10

ME C
60 PRO
RS UR
TE ED
OM AB
FR E C
IN

PRIOR TO PROCEEDING WITH WORKS AT SITE.


ST
FIR

02 01
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN OF
10 09
08
ALL TEMPORARY WORK RELATED TO THE CONSTRUCTION
07 (TYPICAL ROOF SLOPE = 1/2%)

(TYPICAL
check

ROOF
SLOPE
1/2%)
=
PROCESS.
cabin

RD

8. CONTRACTOR IS REQUIRED TO VISIT THE SITE AND GET


06
05
04
AUTO
MA
BARRIE TIC
FAMILIARIZED WITH SITE CONDITIONS, PRIOR TO
TO
R SPEED NG
BREAK ILDI
ER BU

COMMENCEMENT OF WORKS AT SITE.


check OS
ED

KSA
cabin OP
CAMERA CABIN OFFICE
001
PR

STEEL
with STEBARRIER
EL CH
AIN
3.78

PLASTI
BARRIE C STEEL
SPEED R with STEBARRIER
BREAK
ER EL CH
AIN

ANE
CAMERA AUTO
MA
BARRIE TIC

VIP L
R
03
02 VIP LAN
E
STEEL
with STEBARRIE
01 EL CH R
AIN
CHEC
CABINK

TO BAHR
STEEL
PLASTI
BARRIE C
R
SPEED
BREAK
ER
AIN
3.08

with STEBARRIER
EL CH STEEL
AIN with STEBARRIER
AUTO EL CH
MA
BARRIE TIC PLASTI AIN
R BARRIE C
PLASTI R
STEEL CAME
RA BARRIE C AUTO
STEEL BARRIERS MA
CHAIN WITH R BARRIE TIC
R

STEEL
WITH BARRIERS
STEEL
CHAIN STEEL
with STEBARRIER
3.84

STEEL EL CH
WITH BARRIERS
3.00

AIN
STEEL
CHAIN
SPEED
BREAKE
4.14
3.00

R
STEEL PLASTI PLASTI
CHAIN BARRIERS 1200MMC BARRIE C
WIT DISTANBARS
RRIER
H STE CE
EL CAME
RA

STEEL
with STEBARRIER
EL CH
AIN

CARD
READER
M.H

BUS CAB
IN F.F.
L 600
MM RAMP

SITE LOCATION PLAN


SCALE 1:250

IN
OUT

SPECIFICATIONS FOR ROAD BLOCKERS :


ROAD BLOCKERS SECURITY & SAFETY
EXISTING BOLLARDS
USING : Y:\03 KFCA Projects\05 Misc Projects\38 VIP Lane Road Blockers (KSA & BH)\VIP LANE_ROAD BLOCKERS\20220823_DD VIP LANE_ROAD BLOCKERS.dwg

a) Hydraulic road blockers impact tested to pass 68, ASTM IWA14 classification.
ROAD BLOCKERS b) Provide high security protection from vehicle hostile attacks.
c) The blockers must include hydraulic system including hand pump in case of
power failure, push button, photo cell, loop detection and must be interlocked
with arm barrier system and its arrangements as per end user's requirements.
SECURITY & SAFETY
REV. DATE DESCRIPTION REMARKS
SPECIFICATIONS BOLLARDS MATCHING
1. Road Blocker Height : 1000mm WITH EXISTING
2. Wall Thickness : Side blades 20mm, Top sheet 10mm, Front
sheet 4mm
ROAD BLOCKERS
3. Finish : Electrostatic Powder Coated - Wet Paint
4. Motor Power : 4-15 kW A
5. Power Supply : 3 Phase 380 V (±10) AC, 50/60 Hz KS
SECURITY & SAFETY TO PROJECT
BOLLARDS 6. Speed : 3-5 sec

1.5
TO

PROPOSED ROAD BLOCKERS

0
7. Axle Load : 30 Tons
CE

BA

M IN
RO CAB
RA

8. Compatibility with Access Control Systems : Photo cell ,loop detector F AT VIP LANE KSA & BH
HR

S
ER URE
MI

9. Impact resistance : 1800.5 Ki T


C

AIN

ME ED
MA

10. Control panel : PLC 53 ROC SECURITY & SAFETY


P
RK

11. Operating Temperature : -25°C - +50°C I R ST BOLLARDS MATCHING


S

TO

F
00 12. Protection Class : IP-67 CLIENT
55 WITH EXISTING
KS
A
13

66 PRO
ME CE

N
AI
TE DU
29

H R
14

RS RE
98

BA
85

TO
FR CA
0

OM BI
C 5

60

75 PRO
ER
1

IN
8

CONSULTANT
OM AB
FIR N
AM

ME CE

F R C
IC

ST
TE DU
CA

R S RE
MA

TE EDU
RS R
T

16
EY

E
RK

M C
FR E C

60 PRO
ES

OM AB

ST
IR
FI IN

F
RS

COEPP LICENSE No: FB/102


T

DRAWING TITLE
PROPOSED LOCATION OF ROAD BLOCKERS
AT VIP LANE (KSA & BH)
: Thursday, August 18, 2022

2
71
15 PRODUCT DIMENSIONS (REFERENCED FROM CATALOGUE)
PRINTED BY: Ali, Umar [NN-BH]

PROJECT No: 2022xxx

DRAWN DESIGNED CHECKED APPROVED


VIP LANE PROCEDURE AREA - KSA SIDE VIP LANE PROCEDURE AREA - BAHRAIN SIDE DC/UA MN MN HA
SCALE 1:500 SCALE 1:500 SCALE : AS SHOWN DATE DWG. SIZE
ROAD BLOCKER
USER : p007327F
: 10:30 AM

17 AUG 2022 A1

DRAWING NO: REV. NO.

SK-AR-A1-101 R0
ON