Close-coupled centrifugal pumps with open impeller.
The built-in backflow preventer avoids reverse siphoning when the
pump is stopped and assures automatic re-priming at the next start.
The pump re-primes itself even if partially filled with liquid and
with completely empty suction pipe.
A: version with pump casing and lantern bracket in cast iron.
B-A: version with pump casing and lantern bracket in bronze
(the pumps are supplied fully painted).
Applications
For clean or slightly dirty water, also with solids up to 10 mm
grain size for A 40, A 50 and 15 mm for A 65, A 80.
For draining a basin or a sump.
For irrigation. For civil and industrial applications.
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Room temperature up to 40 °C.
Maximum permissible working pressure up to 6 bar (10 bar for
A 80-170).
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
A three-phase 230/400 V ± 10% up to 3 kW;
400/690 V ± 10% from 4 to 7,5 kW;
AM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Materials Insulation class F.
Components A B-A Protection IP 54.
Classification scheme IE3 for three-phase motors from 0,75 kW.
Pump casing Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Suction flange
Inspection cover Cast iron Bronze EN 60335-1, EN 60335-2-41.
(for A 65, A 80) GJL 200 EN 1561 G-Cu Sn 10 EN 1982
Lantern bracket Special features on request
Impeller Other voltages.
Shaft Chrome-nickel steel Frequency 60 Hz (as per 60 Hz data sheet).
1.4305 EN 10088 (AISI 303) Cr-Ni-Mo steel Protection IP 55.
Chrome steel 1.4104 EN 10088 1.4401 EN 10088 (AISI 316) Special mechanical seal.
(AISI 430) for A 40/110, A 65-150A,B Higher or lower liquid or ambient temperatures.
Mechanical seal Carbon - Ceramic - NBR Construction with bearing bracket.
120
30 100
H
H ft
m A 80-170 80
20
A 65-150 60
40
10 A 50-125
A 40-110 20
0 0
0 m 3/h 10 20 30 40 50 60 70
0 Q l/min 200 300 400 500 600 700 800 900 1000 1100
72.855
A Self-Priming Centrifugal Pumps
with open impeller
3~ 230 V 400 V 1~ 230 V P1 P2 m3/h 3,6 4,8 6 7,5 8,4 9,6 10,8 12 15 18
Q
A A A kW kW HP l/min 60 80 100 125 140 160 180 200 250 300
A 40-110B/A AM 40-110B/A
B-A 40-110B/A 2,8 1,6 B-AM 40-110B/A 4,5 0,85 0,55 0,75 12,9 12,4 11,8 11 10,4 9,8 9 8,3 6 3,4
A 40-110A/B AM 40-110A/A
Hm
B-A 40-110A/B 3,7 2,2 B-AM 40-110A/A 6 1,1 0,75 1 15,4 14,9 14,2 13,3 12,9 12,1 11,3 10,5 8,4 5,6
P1 Maximum power input. P2 Rated motor power output. H Total head in m. B-A, B-AM = Bronze construction. Tolerances according to UNI EN ISO 9906:2012
A Self-Priming Centrifugal Pumps
with open impeller
Self-priming capability
with DN
Tubo 40 mmDN
aspirante suction
40 mm pipe with DN
Tubo 50 mmDN
aspirante suction
50 mm pipe with DN
Tubo 65 mmDN
aspirante suction
65 mm pipe
20 20 15
A 40-110 A 50-125 t
A 65-150
L =1m
min
L= 1 m L= 1 m
t t C
min min
10
B C
A
10 10 B
B
5
A A
0 0 0
0 2 4 6 0 2 4 6 0 2 4 6
Hs m Hs m Hs m
Tubo aspirante
with DN 80 mmDN 80 mm
suction pipe
10
A 80-170
t
L= 1 m
min
5
A
≥ 0,5 m
L
0
0 2 4 6
Hs m
Hs
3.93.021.2
HsHs(m)(m)
Suction lift.di aspirazione.
Altezza
L L(m)(m)Horizontal
Lunghezza length
del of suction
tubo pipe orizzontale
aspirante above the water
sopralevel.
il livello dell'acqua.
t t(min) Self-priming time.
(min) Tempo di autoadescamento.
Risultati di collaudo con acqua fredda
A Self-Priming Centrifugal Pumps
with open impeller
C Ø 107 58
H ft
10
Hm
56
30
H ft
54 40
8 50
10
6 20 30
4 20
10
5
2
10
0 0
0 3 5 10 15 20
Q m /h 0 0
0 l/min 100 200 300 0 3
1,0 Q m /h 5 10 15 20 25 30 35
0 l/min 100 200 300 400 500
0,8 A 1,0
P kW
l/s 1
P HP
0,6 B 0 2 3 4 5 6 7 8 9
0,4 2
0,5 2.5
0,2 A
2.0
0 0
P kW
P HP
60
B 1.5
1
C
1.0
η (%)
40 A
0.5
20 B
0 0
0
8 25
8
NPSH m
NPSH m
6 6 20
NPSH ft
20
NPSH ft
15
4 4
10 10
2 2
5
0 0 0 0
0 3 5 10 15 20 72.370
Q m /h 0 Q m3/h 5 10 15 20 25 30 35
0 U.S. g.p.m. 50 100 150 200 250 0 U.S. g.p.m.50 100 150 200 250 300
40
A Ø 150 100 A Ø 165 120
30 50
55 57
A 65-150 A 80-170
59 100
30 B Ø 153
80
B Ø 133 η 61%
59 80
20 57
C Ø 126 55 20
Hm
Hm
60
H ft
50 60
H ft
40 40
10 10
20
20
0 0
0
Q m /h 10 20 30 40 50 60 70
3
0 0
0 3 10 20 30 40 50 60 0 l/min 200 400 600 800 1000
Q m /h
0 l/min 200 300 400 500 600 700 800 900 1000 7 A 10
0 l/s 2 4 6 8 10 12 14 16 8
P HP
B
P kW
5
5 6
A 6 3 4
4
5 2
1
P kW
3 4
P HP
B
60
2 C 3 A
η (%)
2 40 B
1
1
20
0 0
10 0
30 10
30
NPSH m
NPSH m
8
8
NPSH ft
NPSH ft
6 20 6 20
4 4
10 10
2 2
0 0 0 0
0
Q m /h 10 20 30 40 50 60 70
3
0 Q m3/h 20 40 72.371 60
A Self-Priming Centrifugal Pumps
with open impeller
275
208
B-A 40-110A/B 23,3
206
B-AM 40-110A/A 23,5
B-A 40-110B/A 21,6
B-AM 40-110B/A 22,5
70 16 50
100 140
199 190
490
147 96 102
kg
G2
ISO 228 A 50-125A/A 29,9
AM 50-125AE 31
A 50-125B/A 28
AM 50-125BE 29,1
A 50-125CE 26,9
ISO 228
295
G2
AM 50-125CE 27,8
231
223
B-A 50-125A/A 33,6
14 B-AM 50-125AE 33,6
4.93.103 B-A 50-125B/A 31
70 16 30 50 B-AM 50-125BE 32,6
100 140 B-A 50-125CE 29,6
263 190 B-AM 50-125CE 30,6
fM
172 115 121
G 2 1/2
ISO 228
mm
TIPO
TYPE kg
fM H w
660
202
G3 132 140
ISO 228
kg
A 80-170A/A 85,8
A 80-170B/A 80,3
ISO 228
G3
427
342
317
B-A 80-170A/A 95,6
17
B-A 80-170B/A 90,1
110 22 47 60
145 220
311 280
175
A Self-Priming Centrifugal Pumps
with open impeller
Features
1.94.032
Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows A series pumps to be selected for
use with different types of liquids.
Solid parts
The open impeller allows for the passage of suspended solids in pumped liquid.
Exclusive design
An innovative, patented guard prevents contact with rotating parts, proving pro-
tection to the end user whilst allowing for inspection of the mechanical seal.
Reliable
The bearing and shaft are designed to ensure the reduction of the stress, provi-
ding high reliability under all operating conditions.