Busbar Material: As per SLD (0.7A/Sqmm for Al & 1.7A/Sqmm for Copper)
B LT CABLES
Page 1 of 9
Apartment, Belgaum, Bangalore.
C LT CABLE TERMINATION
Supply, Installation, Testing and Commissioning of Compression type
cable gland, copper sockets for copper cables, insulation tape, anti
3.00
corrosive paste, brass clamps for gland earthing with 14 SWG copper wire
to connect to nearest earth flat.
Refer Standard: IS 12943 for single compression, BS 6121 for Double
compression
Gland type: Brass with nickel plated for Armoured cables and PVC for
copper flexible cables.
Compression: Single for Indoor, Double for Outdoor
Sealing Ring: Natural rubber for indoor, Neoprene for Outdoor
D DISTRIBUTION BOARDS
Supply, Installation, Testing and Commissioning of MCB Distribution board
4.00
as per approved installation dwgs.
All the Swithgear should be LOTO compatible
Standard Reference: IS 8623
Enclosure: 1.2mm CRCA Sheet Steel, Powder Coated
Door: Double Door
Protection: IP 42
Cable Entry: Top & Bottom
For UPS distribution ELCB/RCBO/RCCB's shall be harmonic resistant
Bus bar: Shall be tinned Copper and 200% rating for UPS DB Neutral Link
MCB's: 25/16/10kA 'C' Curve for Lighting & Raw power, 16/10kA 'D' Curve
for UPS Distribution
Note: 1)
Separate Earth bus/Neutral bus for each phase. 2) Each Circuit shall have
yellow ferrules with circuit number. 3) Accessories required for installation
of DB's on Wall/Column/Gyp Board shall be considered. 4) DB's shall be
covered with powder coated (paint should match with DB Color) wire ways
all around and up to ceiling to receive incoming circuits, how ever raceway
shall be considered as a separate items & same shall be paid under
raceway item. 5) Laminated A3 OR A4 size SLD & Control drawing copy
shall be pasted inside DB door 6) Safe shroud for Neutral link shall be
provided. 7) SPD should be part of Integral of DB and should not be install
outside of the DB. 8) All DB doors are metal door only unless otherwise
specified. 9) All MCB's Should be as per LOTO Requirement
Page 2 of 9
Apartment, Belgaum, Bangalore.
NOTE:
1) Conduits running above false ceiling in multiples shall be supported by
Slotted GI 'C' channel at distance not more than 0.5mtrs intervals. OR else
with spacers & saddles at an intervals of 0.5mtrs. 2) Accessories shall
includes Bends, Collars, junction boxes, Spacers, saddles, screws,
Flexibles (all are MS, PVC, GI). 3) Conduits shall be Medium duty & ISI
marked. 4) The number of wires drawn in each conduit shall be as per IS
694 code. 5) No different phases shall be drawn in same conduit.
5.06 32mm dia Medium Class PVC FRLS Conduit Mtrs Rate
5.07 25mm dia Medium Class PVC FRLS Conduit Mtrs Rate
5.08 19mm dia Medium Class PVC FRLS Conduit Mtrs Rate
5.09 100mm dia Medium Class GI Conduit Mtrs 10 10
5.10 32mm dia Medium Class GI Conduit Mtrs 5 5
5.11 32mm dia Medium Class MS Conduit Mtrs Rate
5.12 25mm dia Medium Class MS Conduit Mtrs 10 10
5.13 19mm dia Medium Class MS Conduit Mtrs Rate
Supply,Installation, Testing & commissioning of GI Back box on
Ceiling, Wall, In floor etc. for Power wiring and any other control
wiring
5.14 1M Switch Plate with GI Back Box Nos 4 4
5.15 2M Switch Plate with GI Back Box Nos 26 1 27
5.16 3M Switch Plate with GI Back Box Nos 26 26
5.17 4M Switch Plate with GI Back Box Nos 1 2 3
5.18 6M Switch Plate with GI Back Box Nos 10 10
5.19 8M Switch Plate with GI Back Box Nos 2 2
5.20 9M Switch Plate with GI Back Box Nos 2 2
5.21 12M (2*6) Switch Plate with GI Back Box Nos 4 4
5.22 16M (2*8) Switch Plate with GI Back Box Nos 2 2
Page 3 of 9
Apartment, Belgaum, Bangalore.
6.05 Supply, installation, testing and commissioning of 16A One Way Switch Nos 12 12
6.06 Supply, installation, testing and commissioning of 6A Two Way Switch Nos 12 12
Supply, installation, testing and commissioning of 10 A Bell Push With
6.07 Nos 2 2
Indicator
6.08 Supply, installation, testing and commissioning of 1M Fan Regulator Nos 10 10
6.09 Supply, installation, testing and commissioning of Call Bell Nos 2 2
Supply, installation, testing and commissioning of RJ45 Socket along with
6.10 Nos 2 2
GI Backbox
Supply, installation, testing and commissioning of RJ11 Socket along with
6.11 Nos 2 2
GI Backbox
Supply, installation, testing and commissioning of TV Outlet Point along
6.12 Nos 2 2
with GI Backbox
Supply, installation, testing and commissioning of Mechanical Limit Switch- Plunger
6.13 Type ( 1NO ,1NC WITH SPDT ACTION)
Nos 6 6
Industrial Sockets / Isolators
Terminal : Phosphor bronze
Enclosure: Polycarbonate upto 125A, MS Powder Coated above 125A.
IP Class :IP44 (Indoor), IP55 (Outdoor)
Note: The enclosure color of socket shall be different for different Source
G EARTHING SYSTEM
7.00 EARTHSTRIPS
Supply, Installation on trays/in ground/on wall/in trench etc, Testing and
Commissioning of the Earth strips as per installation standard IS 3043
Strips above ground: GI
Strips below groung: MS
Accessories: Welding for GI/MS, Brazing for Copper, GI nut bolts for
connection at eqpt end/PVC sleeves for copper strips/Epoxy Insulated
mounts shall be considered
7.01 50 x 6 mm - GI strip Mtrs Rate
7.02 25 x 3 mm - GI strip Mtrs 10 10
7.03 25 x 3 mm - CU strip Mtrs 5 5
7.04 SITC of 8SWG Cu Wire Mtrs 30 10 40
I LIGHT FIXTURES
Page 4 of 9
Apartment, Belgaum, Bangalore.
Supply, Installation, testing & commisioning of 100W Street Light LED Light
9.04 Fixture with Cross Aarm & 2.5KV Surge Protection LED Driver. MAKE: Nos 1 1
BAJAJ, MODEL NO: BRTFG 100W LED CR LED or Equivalent.
10.01 SITC of 16A DP Manual Change over Switch with necessary accessories. Nos 1 1
K SAFETY ITEMS
11.00 For Metering Panel etc
2mm thick Fire Rated PVC Insulated rubber Mats (Class A) 3.3KV grade
11.01 Sqm 1 1
(As per IS: 15652:2006)
11.02 Approved plant SLD duly Framed Nos 1 1
TOTAL
Add: SGST 9%
Add: CGST 9%
GRAND TOTAL
Page 5 of 9
Sl No
Apartment, Belgaum, Bangalore.
C LT CABLE TERMINATION
Supply, Installation, Testing and Commissioning of Compression type
cable gland, copper sockets for copper cables, insulation tape, anti
2.00
corrosive paste, brass clamps for gland earthing with 14 SWG copper wire
to connect to nearest earth flat.
Refer Standard: IS 12943 for single compression, BS 6121 for Double
compression
Gland type: Brass with nickel plated for Armoured cables and PVC for
copper flexible cables.
Compression: Single for Indoor, Double for Outdoor
Sealing Ring: Natural rubber for indoor, Neoprene for Outdoor
Copper Flexible cables (Confirm to as per IS 694).
2.01 3Cx4 Sq.mm YY - Single Compression Nos. 2 120 240
D DISTRIBUTION BOARDS
Supply, Installation, Testing and Commissioning of MCB Distribution board
3.00
as per approved installation dwgs.
All the Swithgear should be LOTO compatible
Standard Reference: IS 8623
Enclosure: 1.2mm CRCA Sheet Steel, Powder Coated
Door: Double Door
Protection: IP 42
Cable Entry: Top & Bottom
For UPS distribution ELCB/RCBO/RCCB's shall be harmonic resistant
Bus bar: Shall be tinned Copper and 200% rating for UPS DB Neutral Link
MCB's: 25/16/10kA 'C' Curve for Lighting & Raw power, 16/10kA 'D' Curve
for UPS Distribution
Note: 1)
Separate Earth bus/Neutral bus for each phase. 2) Each Circuit shall have
yellow ferrules with circuit number. 3) Accessories required for installation
of DB's on Wall/Column/Gyp Board shall be considered. 4) DB's shall be
covered with powder coated (paint should match with DB Color) wire ways
all around and up to ceiling to receive incoming circuits, how ever raceway
shall be considered as a separate items & same shall be paid under
raceway item. 5) Laminated A3 OR A4 size SLD & Control drawing copy
shall be pasted inside DB door 6) Safe shroud for Neutral link shall be
provided. 7) SPD should be part of Integral of DB and should not be install
outside of the DB. 8) All DB doors are metal door only unless otherwise
specified. 9) All MCB's Should be as per LOTO Requirement
3.01 Flat, 2 Row 14 Module Flexy PDB - 1 & 2 Set 1 3500 3500
Supply, erection, testing and commissioning of MCB DB double door type,
IP42 powder coated 2 Row 14 Module Flexy DB comprising of "C" curve
MCB's for Lighting & Power DB.
Incommer
1 No - 20A DP MCB
1 No - 16KA B+C Type SPD with 16A DP MCB
Outgoings
13 Nos - 16A SP MCB
6 Nos - 6A SP MCB
4 Nos - Dummy
Including all interconnections & accessories etc. as reqd
Page 7 of 9
Apartment, Belgaum, Bangalore.
NOTE:
1) Conduits running above false ceiling in multiples shall be supported by
Slotted GI 'C' channel at distance not more than 0.5mtrs intervals. OR else
with spacers & saddles at an intervals of 0.5mtrs. 2) Accessories shall
includes Bends, Collars, junction boxes, Spacers, saddles, screws,
Flexibles (all are MS, PVC, GI). 3) Conduits shall be Medium duty & ISI
marked. 4) The number of wires drawn in each conduit shall be as per IS
694 code. 5) No different phases shall be drawn in same conduit.
5.05 Supply, installation, testing and commissioning of 16A One Way Switch Nos 6 12 72
5.06 Supply, installation, testing and commissioning of 6A Two Way Switch Nos 6 12 72
Supply, installation, testing and commissioning of 10 A Bell Push With
5.07 Nos 1 12 12
Indicator
5.08 Supply, installation, testing and commissioning of 1M Fan Regulator Nos 5 25 125
5.09 Supply, installation, testing and commissioning of Call Bell Nos 1 110 110
Supply, installation, testing and commissioning of RJ45 Socket along with
5.10 Nos 1 25 25
GI Backbox
Supply, installation, testing and commissioning of RJ11 Socket along with
5.11 Nos 1 25 25
GI Backbox
Supply, installation, testing and commissioning of TV Outlet Point along
5.12 Nos 1 15 15
with GI Backbox
Supply, installation, testing and commissioning of Mechanical Limit Switch- Plunger
5.13 Type ( 1NO ,1NC WITH SPDT ACTION)
Nos 3 35 105
G EARTHING SYSTEM
6.00 EARTHSTRIPS
Supply, Installation on trays/in ground/on wall/in trench etc, Testing and
Commissioning of the Earth strips as per installation standard IS 3043
Strips above ground: GI
Strips below groung: MS
Accessories: Welding for GI/MS, Brazing for Copper, GI nut bolts for
connection at eqpt end/PVC sleeves for copper strips/Epoxy Insulated
mounts shall be considered
6.01 SITC of 8SWG Cu Wire Mtrs 5 18 90
CABLE TRAYS
150 mm x 60mm x 0.7mm thickness Perforated type with 2R 25 x 3 mm -
7.01 Mtrs 5 145 725
GI strip
450 mm x 60mm x 1.2mm thickness Perforated type with 2R 25 x 3 mm -
7.02 Mtrs 2.5 280 700
GI strip
Page 8 of 9
Apartment, Belgaum, Bangalore.
I LIGHT FIXTURES
Supply, Installation, testing & commisioning of 40W 4Feet Endura LED
Light Fixture with CCT-4000K, CRI>80, UGR<19 and 2.5KV Surge
9.01 Nos 7 140 980
Protection LED Driver. MAKE : PHILIPS, MODEL NO:BN 108C LED 40S
PSU CDL WH or Equivalent.
Supply, Installation, testing & commisioning of 20W 2Feet Endura LED
Light Fixture with CCT-4000K, CRI>80, UGR<19 and 2.5KV Surge
9.02 Nos 2.5 110 275
Protection LED Driver. MAKE : PHILIPS, MODEL NO:BN108C LED 20S
PSU CDL WH or Equivalent.
Supply, Installation, testing & commisioning of 1200mm dia Brushless DC
9.03 Nos 8 140 1120
Motor Ceiling Fan
Supply, Installation, testing & commisioning of 10W Mirror LED Light
9.04 Nos 3 80 240
Fixture with 2.5KV Surge Protection LED Driver.
9.08 Supply, Installation, testing & commisioning of 4W Foot Lamp Nos 2 110 220
K SAFETY ITEMS
11.00 For Metering Panel etc
2mm thick Fire Rated PVC Insulated rubber Mats (Class A) 3.3KV grade
11.01 Sqm
(As per IS: 15652:2006)