A consistent design of offers from All Merlin Gerin offers are designed according to
Medium Voltage to Ultra terminal electrical, mechanical and communication
consistency rules.
The products express this consistency by their
overall design and shared ergonomics.
Electrical consistency:
Mechanical consistency:
Communication consistency:
Thanks to the use of standard Web technologies, you can offer Each product complies with global choices in terms of
your customers intelligent Merlin Gerin switchboards allowing communication protocols (Modbus, Ethernet, etc.) for simplified
easy access to information: follow-up of currents, voltages,
powers, consumption history, etc.
integration in the management, supervision and monitoring
systems.
Guiding Tools
for more efficient design
and implementation
of your installations.
1
0
Trihal
MV/LV dry cast resin
transformer
from 160 to 5000 kVA
Evolis
MV vacuum
switchgear and
components
from 1 to 24 kV.
These technical guides help you comply with The CAD software and tools enhance
installation standards and rules i.e.: productivity and safety.
The electrical installation guide, the They help you create your installations
protection guide, the switchboard by simplifying product choice through
implementation guide, the technical booklets easy browsing in the Guiding System
and the co-ordination tables all form genuine offers.
reference tools for the design of high- Last but not least, they optimise
performance electrical installations. use of our products while also complying
For example, the LV protection co-ordination with standards and proper procedures.
guide - discrimination and cascading -
optimises choice of protection and
connection devices while also increasing
markedly continuity of supply in the
installations.
2
0
Pragma Canalis
Enclosures for Prefabricated Busbar
distribution Trunking
switchboards from 25 to 4000 A
up to 160 A
PowerLogic
Power
management
Training
3
LF and SF circuit breakers 0
Two ranges of comprehensive and proven LF circuit breakers from 7.2 kV to 17.5 kV
three-pole circuit breaker units for indoor
installation using SF6 technology.
PE55761
Both compact and dependable, they are
ideally suited to the most demanding
applications and integrate perfectly
in the Merlin Gerin Guiding System.
Both of these circuit breaker ranges
meet IEC standard 62271-100.
4
General contents 0
Presentation 6
Panorama 14
LF circuit breakers 17
SF circuit breakers 29
5
Presentation LF circuit breakers 0
General
Applications
LF circuit breakers are three-pole indoor MV circuit breakers.
They are mainly used for operation and protection of public, industrial and tertiary
distribution networks from 7.2 to 17.5 kV.
Through their anti-seismic qualification, they are particularly well suited to nuclear
or thermal power production installations and applications in heavy industries
such as the petrochemical industry.
Through their compact dimensions and harmonized range, LF circuit breakers
are positioned very favorably on the retrofit market.
With self expansion, the breaking technique used in these circuit breakers,
all current types, capacitive and inductive, can be made or broken without
generating overvoltage which could damage your installation.
The LF circuit breaker is therefore ideally suited to operating capacitor banks.
6
Presentation LF circuit breakers 0
General (cont.)
DE51242
7
Presentation SF circuit breakers 0
General
Equipment description
The SF circuit breaker comprises a basic fixed version with:
PE55765
b 3 main independent poles, that are mechanically linked and each comprising
a “sealed pressure system” type insulating enclosure. The sealed enclosure is filled
with low pressure SF6 gas.
b a stored energy operating mechanism of:
v of manual RI type (that can be electrically operated as an option) for SF1 and
SFset circuit breakers
v of electrical GMH type for SF2 circuit breakers.
v The circuit breaker’s stored energy operating mechanism gives the device a making
and breaking speed that is independent of the operator, whether the order is electrical
or manual. When equipped with an electrical operating mechanism, the circuit breaker
can be remotely controlled and it is possible to carry out reclosing cycles.
b a front panel with the manual operating mechanism and the indicators
b upstream and downstream terminals for connection of power circuits
b a terminal for connection of external auxiliary circuits.
SF1 circuit breakers with an RI type operating mechanism
Each device can be optionally equipped with:
b an electrical operating mechanism for SF1 and SFset
b a support frame fitted with rollers and floor securing brackets for a fixed installation
b locking of the circuit breaker in the open position by a keylock installed on the
PE55766
control panel
b a pressure switch for the high performance versions
b a Harting 42-pin type LV connector.
The SFset includes an independent protection chain
The SFset is provided with a fully autonomous integrated protection chain
(with a VIP type control unit) operating without an auxiliary power source.
The VIP protection unit exists in two models: VIP300P and VIP300LL.
kA
25
DE55730
20 VIP300LL
16
SF1
Mitop
CS VIP
SF2 circuit breakers with a GMH type operating mechanism
Applications
SF circuit breakers are 3-pole MV circuit breakers for indoor installation. They are
mainly used for switching and protection of networks from 17.5 to 40.5 kV in primary
and secondary power distribution.
Because the SFset protection chain is autonomous in terms of power, this circuit
breaker is particularly suited to certain dispersed installations on the network.
The autocompression breaking technique used in these circuit breakers means that
making or breaking all types of compacitive or inductive currents can be achieved
without dangerous overvoltages for the switchgear connected to the network.
The SF6 circuit breaker is therefore well suited to operating capacitor banks.
8
Presentation SF circuit breakers 0
General (cont.)
DE51238
9
Presentation LF and SF circuit breakers 0
Increased endurance
61051N
The mechanical and electrical endurance of Merlin Gerin SF6 breaking devices
are in conformity with the most demanding specifications recommended by the IEC.
These devices therefore meet requirements for even the most exposed of networks.
Less maintenance
Throughout the device’s service life, which in normal operating conditions may be
at least 30 years, the only maintenance required is on the mechanical operating
mechanism, once every 10 years or every 10,000 operations.
Although no maintenance is performed on poles, a diagnosis is possible:
b contact wear can be checked by external pole measurement
b SF6 pressure can be continually monitored by a pressure switch.
Environmentally-friendly
Merlin Gerin devices have been designed to ensure protection of the environment:
b the materials used, both insulating and conductive, are identified and easy
to separate and recycle,
b the SF6 gas is under control from production through to the circuit breaker’s end
of life. In particular it can be recovered at the end of the circuit breaker’s life and
re-used after treatment in line with the new European directive,
b an end of life manual for the product details procedures for dismantling and
recycling components.
Quality Assurance
During production, each circuit breaker undergoes systematic routine tests
in order to check quality and conformity:
b pole sealing check
b checking the correct mechanical operation of the device,
plus its associated locking mechanisms
b checking simultaneous closing of contacts
b checking power frequency insulation level
b checking main circuit resistance
b checking auxiliary circuit insulation
b checking auxiliary circuit electrical resistance
b checking switching speeds
b checking the switching cycle
b measuring the switching times.
The results are recorded on the test certificate for each device
which is initialed by the quality control department.
10
Presentation LF and SF circuit breakers 0
Certification
The quality system for the design and production of LF and SF range circuit breakers
is certified in conformity with ISO 9001: 2000 quality assurance standard requirements.
DE55745
The environmental management system adopted by Merlin Gerin production sites
for the production of LF and SF range circuit breakers has been assessed and
judged to be in conformity with requirements in standard ISO 14001.
DE55746
11
Presentation LF circuit breakers 0
Example of integration in an
MCset cubicle
PE55754
12
Presentation SF circuit breakers 0
Example of integration in an
SM6 cubicle
PE55755
13
LF and SF circuit breakers Panorama 0
Circuit breakers
LF range circuit breakers SF range circuit breakers
14
LF and SF circuit breakers Panorama (cont.) 0
I1 = 165A RMS
I2 = 166A RMS
I3 = 167A RMS
Separate catalogue
15
0
16
LF and SF circuit breakers LF circuit breakers 0
Presentation 6
Panorama 14
General characteristics 18
Description of functions 20
Opening circuit 20
Remote control 21
Indication and locking/interlocking 22
Wiring diagram for auxiliary contacts 23
Dimensions 24
Order form 25
Offer structure 26
SF circuit breakers 29
17
LF circuit breakers General characteristics 0
18
LF circuit breakers General characteristics (cont.) 0
Specific applications
Protection of generators and power station auxiliaries
All circuit breakers in the LF range break short circuit currents with an asymmetry
of at least 30%.
In cases where the network constant X/R is greater than 45 ms, the asymmetry
to be broken is higher; this is often the case of circuit breakers protecting nuclear
or thermal power station auxiliaries or circuit breakers that are close to generator sets
or large transformers.
Specific tests have been carried out:
Circuit breakers kV kA Asymmetry
LF2 7.2 43.5 50%
LF3 7.2 43.5 50%
12 40 50%
17.5 25 100%
Switching and protection of capacitor banks
LF range circuit breakers are particularly well suited to switching and protection
of capacitor banks; they are classed C2 according to standard IEC 62271-100.
Tests carried out according to the standard for breaking at 400 A with making
and breaking cycles in case of a capacitor bank with a making current of 20 kA.
Additional tests have been carried out: please consult us.
19
LF circuit breakers Description of functions 0
Opening circuit
Composition
DE55701EN
Operating device
Undervoltage release (YM)
This release unit causes the systematic opening of the circuit breaker when its
DE60094
supply voltage drops below a value less than 35% of the rated voltage, even if this
drop is slow and gradual. It can open the circuit breaker between 35% and 70% of
its rated voltage. If the release unit is not supplied power, manual or electrical closing
of the circuit breaker is impossible. Closing of the circuit breaker is compulsory when
the supply voltage of the release unit reaches 85% of its rated voltage.
Shunt opening release (1)
Characteristics
Power supply See page 25
DE60089
This specific release unit comprises a low consumption unit and is specifically used
for Sepam 100LA self-powered relays.
Characteristics
Power supply Direct current
Low energy release (3) Threshold 0.6 A < I < 3 A
Any tripping due to the Mitop release unit is momentarily indicated by an SDE type
changeover contact.
20
LF circuit breakers Description of functions 0
Remote control
(6) (5)
Function
DE55702
Remote control enables the remote opening and closing of the circuit breaker.
Composition
The remote control mechanism comprises:
b an electrical motor with gearing
b a shunt closing release (YF) combined with an anti-pumping device
b an operation counter.
This allows the remote closing of the circuit breaker when the operating mechanism
is armed.
Characteristics
Power supply See page 25
Electrical motor and gearing (4) Threshold V AC 0.85 to 1.1 Un
V DC 0.85 to 1.1 Un
DE60151
Consumption V AC 160 VA
V DC 50 W
The anti-pumping relay enables the guaranteeing of opening priority in the case
of a permanent closing order. This therefore avoids the device being caught
in a uncontrolled opening-closing loop.
Operation counter
DE60087
21
LF circuit breakers Description of functions 0
The number of contacts available depends on the options chosen on the operating
mechanism.
In the basic configuration, the circuit breaker’s operating mechanism comprises
a total of:
b 6 normally closed contacts (NC)
b 6 normally open contacts (NO)
b 1 changeover contact (CHG).
The usage procedure for auxiliary contacts is given in the following table:
Options
NC contact NO contact
Remote control 1 1
(7) Shunt opening release (each one) 0 1
Undervoltage release 0 0
Mitop low energy release 0 0
In order to know the final number of available contacts, you must deduct the total
number of contacts included in the circuit breaker (6 NC + 6 NO + 1 CHG),
the number of contacts used given in the table below.
E.g: a circuit breaker equipped with a remote control and a shunt trip unit has
the following available contacts:
Operating mechanism 5 NC + 4 NO + 1 CHG.
With a undervoltage release instead of the shunt trip, this circuit breaker would have
the following available contacts:
DE60124
5 NC + 5 NO + 1 CHG.
22
LF circuit breakers Description of functions 0
Close CB
Open CB
M3
YF + YO1 MITOP
anti-pumping or YM
YO2
Remote control
23
LF circuit breakers Dimensions 0
Device
Basic fixed
50 50 connection 50 270
LF1 LF2 LF3 35 25
DE55704EN
A 493 554 728
on
off
330
on
off
590
A 536 34
995
555
B 539 34
Connections
Direct to the device Connection on pads
b LF1 b LF2: b LF3
b LF2 < 2000 A < 95 kV impulse v 2000 A v 2500 A/95 kV impulse
b LF3 < 2500 A and < 95 kV impulse v 1250 A/95 kV impulse v 3150 A/95 kV impulse
v 630 A/95 kV impulse
b LF3: 1250 A/95 kV impulse
63 20 15 52 128
DE55706EN
DE55707
DE55708
3 x 40 8 Ø 12,2
11 11 32
3 x 30
20 40
40
C E
15
60
D E
22,5 4 x ø12
7,5 66 40
3 x 2M10 x 26 (effective length)
24
LF circuit breakers Order form 0
Only one of the boxes (ticked X or filled by Basic fixed circuit breaker Quantity
the needed value) have to be considered between each
horizontal line. Rated voltage Ur (kV)
Orange box X corresponds to none priced functions.
Impulse voltage Up (kVbil)
Frequency 50 Hz 60 Hz
Colour for push buttons and indicators IEC standard ANSI standard
Remote control
Electric motor - MCH 24…32 Vdc 110…127 Vdc/ac
48…60 Vdc/ac 220…250 Vdc/ac
Shunt closing release
24 Vdc 60 Vdc 220 Vdc 220 Vac (50 Hz)
30 Vdc 110 Vdc 48 Vac (50 Hz) 120 Vac (60 Hz)
48 Vdc 125 Vdc 110 Vac (50 Hz) 240 Vac (60 Hz)
25
LF circuit breakers Offer structure 0
1250 A b
2500 A b
31.5 kA 630 A b
1250 A b
2500 A b
3150 A b
40 kA 630 A b
1250 A b
2000 A b
2500 A b
3150 A b
50 kA 630 A b
1250 A b
2000 A b
2500 A b
3150 A b
12 kV-75 kVpeak 25 kA 630 A b
1250 A b
2500 A b
31.5 kA 630 A b
1250 A b
2500 A b
3150 A b
40 kA 630 A b
1250 A b
2000 A b
2500 A b
3150 A b
50 kA 1250 A b
2500 A b
3150 A b
17.5 kV-95 kVpeak 25 kA 630 A b
1250 A b
2000 A b
2500 A b
3150 A b
31.5 kA 630 A b
1250 A b
2000 A b
2500 A b
3150 A b
40 kA 1250 A b
2500 A b
3150 A b
26
LF circuit breakers Offer structure 0
Locking, interlocking
Locking circuit breaker in open position (Ronis or Profalux)
Accessories
Support frame (kit)
DE55732
27
0
28
LF and SF circuit breakers SF circuit breakers 0
Presentation 6
Panorama 14
LF circuit breakers 17
General characteristics 30
SF1 and SFset circuit breakers 30
SF2 circuit breakers 31
Other characteristics 32
Description of functions 33
Opening circuit 33
Remote control 34
Indication and locking/interlocking 35
Wiring diagram for auxiliary contacts 36
Protection, monitoring and control 37
VIP300 protection unit 37
Trip curves for VIP300P and VIP300LL 38
Current sensors and test unit for VIP300 39
Dimensions 40
SF1 and SFset circuit breakers 40
SF2 circuit breakers 43
Order form 44
SF1 circuit breakers 44
SFset circuit breakers 45
SF2 circuit breakers 46
Offer structure 47
SF1 circuit breakers 47
SFset circuit breakers 48
SF2 circuit breakers 49
29
SF circuit breakers General characteristics 0
25 kA 630 A b
1250 A b
Ur 36 kV Isc Ir
Ud 70 kV 50 Hz, 1 min 12.5 kA 400 A b b
Up 170 kV peak 630 A b b
20 kA 630 A b b
1250 A b b
25 kA 630 A b b
1250 A b b
SFset circuit breakers
Phase to phase distance (mm) 220 280
Ur 17.5 kV Isc Ir
Ud 38 kV 50 Hz, 1 min 12.5 kA 1250 A b
Up 95 kV peak 20 kA 400 A b
SFset circuit breakers 630 A b
1250 A b
25 kA 630 A b
1250 A b
Ur 24 kV Isc Ir
Ud 50 kV 50 Hz, 1 min 12.5 kA 400 A b
Up 125 kV peak 630 A b
1250 A b
16 kA 400 A b
630 A b
1250 A b
20 kA 630 A b
1250 A b
25 kA 630 A b
1250 A b
30
SF circuit breakers General characteristics 0
Switching sequences:
b O-0.3 s-CO-15 s-CO
b O-0.3 s-CO-3 min-CO (*)
b O-3 min-CO-3 min-CO (**).
All switching sequences are possible for values without an asterisk.
31
SF circuit breakers General characteristics 0
Specific applications
Capacitor bank protection and switching
SF range circuit breakers are particularly well suited to switching and protection
of capacitor banks; they are classed C2 according to standard IEC 62271-100.
Tests carried out according to the standard break at 400 A and have making and
breaking cycles in the case of the capacitor bank with a making capacity of 20 kA.
Additional tests have been carried out: please consult us.
32
SF circuit breakers Description of functions 0
Opening circuit
Composition
DE55701EN
Operating mechanism
Undervoltage release (YM)
This release unit causes the systematic opening of the circuit breaker when
DE60094
the supply voltage drops below a value of less than 35% of the rated voltage,
even if the drop is slow and gradual. It can open the circuit breaker between 35%
and 70% of the rated voltage. If the release is not supplied power, manual or electrical
closing of the circuit breaker is impossible. Closing of the circuit breaker is compulsory
when the supply voltage to the release unit reaches 85% of its rated voltage.
Shunt opening release (1)
Characteristics
Power supply See page 44
DE60089
This specific release unit comprises a low power consumption unit and is specifically
used for Sepam 100LA, self-powered relays or VIP relays in the case of SFset.
Characteristics
Power supply Direct current
Low energy release (3) Threshold 0.6 A < I < 3 A
Any tripping due to the Mitop release unit is momentarily signaled by an SDE type
changeover contact.
33
SF circuit breakers Description of functions 0
Remote control
(6) (5)
Function
DE55702
Remote control enables the remote opening and closing of the circuit breaker.
Composition
The remote control comprises:
b an electric motor with gearing
b a shunt closing release (YF) associated with an anti-pumping device
b an operation counter.
Consumption V AC 160 VA
V DC 50 W
The anti-pumping relay enables priority to be given to opening in the case
of a permanent closing order. This thus avoids the device being locked in
an uncontrolled opening-closing cycle.
Operation counter
The operation counter is visible on the front panel.
It displays the number of switching cycles (CO) that the device has carried out.
34
SF circuit breakers Description of functions 0
The number of contacts available depends on the options chosen on the operating
mechanism.
In its basic configuration, the circuit breaker operating mechanism comprises
a total of:
b 6 normally closed contacts (NC)
b 6 normally open contacts (NO)
b 1 changeover contact (CHG).
The usage mode for auxiliary contacts is given in the following table:
Options
NC contact NO contact
Remote control 1 1
(7) Shunt opening release (each one) 0 1
Undervoltage release 0 0
Mitop low energy release 0 0
To know the final number of available contacts, the number of contacts used
indicated in the table below must be deducted from the total number of contacts
included in the circuit breaker (6 NC + 6 NO + 1 CHG).
E.g: a circuit breaker equipped with a remote control and a shunt trip
has the following number of contacts available:
Operating mechanism 5 NC + 4 NO + 1 CHG.
With an undervoltage release instead of a shunt trip unit, this circuit breaker
has the following available contacts:
DE60124
5 NC + 5 NO + 1 CHG.
35
SF circuit breakers Description of functions 0
Close CB
Open CB
M3
YF + YO1 MITOP
anti-pumping or YM
YO2
Remote control
36
SF circuit breakers Protection, monitoring and control 0
protection system
The SFset circuit breaker comprises an SF1 into which is integrated a protection
system comprising:
b a set of current sensors installed on the lower current terminals of the pole units.
Two interchangeable sensors, CSa and CSb, sufficient to cover all requirements
from 10 A to 1250 A.
b mounted on the control unit.
b a “Mitop” low consumption, release unit installed on the switching device.
The unit is fully independent and functions without an auxiliary power supply.
Operating principle
The protection system is supplied power by sensors which supply:
b the “current” information”, processed by the protection unit
b the electrical power required for the whole protection system to operate;
VIP unit and Mitop release.
SFset with a VIP protection unit installed on the front panel
All settings are visible and accessible from the front of the device.
PE55772
DE55726
t
VIP300LL protection unit
Mitop
VIP300
t>
t >>
I
1,2 Is 10 Is I >>
Simplified connection arrangement Phase and earthing protection curve
37
SF circuit breakers Protection, monitoring and control 0
Trip curves
VIP300P and VIP 300LL
Trip curves
DE55727
t> t>
t >> t >>
100 100
10 10
6 6
4
3 4
2 3
1.5 2
1 1 1 1.5
1
0.6
0.4 0.6
0.3 0.4
0.2 0.3
0.15 0.2
0.1 0.1 0.1 0.15
0.07 0.1
0.05 0.07
0.05
I/Is I/Is
0.01 0.01
1 10 100 1 1.2 Is 10 100
RI curve SI curve
t (s) t (s)
DE55729
1000 1000
100 100
10 10
6
4
3 6
1 2 1 4
1.5 3
1 2
0.6 1.5
0.4 1
0.3 0.6
0.1 0.2 0.1 0.4
0.15 0.3
0.1 0.2
0.07 0.15
0.05 0.1
I/Is 0.07 I/Is
0.01 0.01 0.05
1 1.2 Is 10 100 1 1.2 Is 10 100
VI curve EI curve
38
SF circuit breakers Protection, monitoring and control 0
In order to achieve the specified performance levels, the VIP300 protection unit must
be used with the specified sensors. The combination of the unit/sensor is essential
in order to comply with characteristics and in particular with:
b operation throughout the whole range
b response time
b accuracy
b short circuit thermal withstand.
Two interchangeable sensors, CSa and CSb, suffice to cover all requirements
from 10 A to 1250 A.
Sensor selection Service current (Is)
CSa 10 A to 200 A
CSb 63 A to 1250 A
39
SF circuit breakers Dimensions 0
350 350
L/W 270
350 350
270 L/W
345 345
L/W
40
SF circuit breakers Dimensions 0
E E P/D P/D
DE55718
H (1)
L/W
H (1)
L/W
E E P/D P/D
DE55720
H (1)
L/W
41
SF circuit breakers Dimensions 0
Connection
Top
SF1, SFset (A) SF1, SFset (B)
20 Ø 24 M8 kA 20 Ø 40 M8
DE55714-A
DE55714-B
DE55709
25
20 (B)
56 56
16 20
17 17
8 13 +0.2
0 12,5 (A) 8 +0.2
13 0
0 17,5 24 36 kV
Bottom
SF1, insulation y 125 kV impulse SF1, insulation y 170 kV impulse SFset
25 ± 0,5
DE55715
DE55716
DE55717
2 Ø M8 2 Ø 10,5 52 2 Ø M8
10
20
18 Ø 40 60 Ø 40
20 20
75
42
SF circuit breakers Dimensions 0
372
L/W
630
L/W 644
Connection
630, 1250 A 2500, 3150 A 2000 A (*)
32,5 35 78 2 Ø M12
DE55723
DE55724
10 70 30
100
90 30 20 Ø 60
35
8 Ø13 49,5
18,5 90
63 70
43
SF circuit breakers Order form 0
Only one of the boxes (ticked X or filled by Basic fixed circuit breaker Quantity
the needed value) have to be considered between each
horizontal line. Rated voltage Ur (kV)
Orange box X corresponds to none priced functions.
Impulse voltage Up (kVbil)
Frequency 50 Hz 60 Hz
Colour for push buttons and indicators IEC standard ANSI standard
Remote control
Electric motor - MCH 24…32 Vdc 110…127 Vdc/ac
48…60 Vdc/ac 220…250 Vdc/ac
Shunt closing release
24 Vdc 60 Vdc 220 Vdc 220 Vac (50 Hz)
30 Vdc 110 Vdc 48 Vac (50 Hz) 120 Vac (60 Hz)
48 Vdc 125 Vdc 110 Vac (50 Hz) 240 Vac (60 Hz)
44
SF circuit breakers Order form 0
Only one of the boxes (ticked X or filled by Basic fixed circuit breaker Quantity
the needed value) have to be considered between each
horizontal line. Rated voltage Ur (kV)
Orange box X corresponds to none priced functions.
Impulse voltage Up (kVbil)
Frequency 50 Hz 60 Hz
Colour for push buttons and indicators IEC standard ANSI standard
Remote control
Electric motor - MCH 24…32 Vdc 110…127 Vdc/ac
48…60 Vdc/ac 220…250 Vdc/ac
Shunt closing release
24 Vdc 60 Vdc 220 Vdc 220 Vac (50 Hz)
30 Vdc 110 Vdc 48 Vac (50 Hz) 120 Vac (60 Hz)
48 Vdc 125 Vdc 110 Vac (50 Hz) 240 Vac (60 Hz)
45
SF circuit breakers Order form 0
Only one of the boxes (ticked X or filled by Basic fixed circuit breaker Quantity
the needed value) have to be considered between each
horizontal line. Rated voltage Ur (kV)
Orange box X corresponds to none priced functions.
Impulse voltage Up (kVbil)
Frequency 50 Hz 60 Hz
Colour for push buttons and indicators IEC standard ANSI standard
Remote control
Electric motor - MCH 24…32 Vdc 110…127 Vdc/ac
48…60 Vdc/ac 220…250 Vdc/ac
Shunt closing release
24 Vdc 60 Vdc 220 Vdc 220 Vac (50 Hz)
32 Vdc 110 Vdc 48 Vac (50 Hz) 120 Vac (60 Hz)
48 Vdc 125 Vdc 110 Vac (50 Hz) 240 Vac (60 Hz)
46
SF circuit breakers Offer structure 0
1250 A b
25 kA 630 A b
1250 A b
36 kV-170 kVpeak 12.5 kA 400/630 A (*) b b
20 kA 630 A b b
C1 1250 A b b
25 kA 630 A b b
1250 A b b
Locking, interlocking
Locking circuit breaker in open position (Ronis or Profalux)
Pressure switch
Option not available for (*) characteristics
Accessories
Support frame (kit)
DE55736
47
SF circuit breakers Offer structure 0
A1 B1 1250 A b
20 kA 630 A b
1250 A b
25 kA 630 A b
1250 A b
C1
Locking, interlocking
Locking circuit breaker in open position (Ronis or Profalux)
Pressure switch
Option not available for (*) characteristics
Accessories
Support frame (kit) (fig. 1)
DE55736
DE55744
Fig. 1 Fig. 2
48
SF circuit breakers Offer structure 0
Locking, interlocking
Locking circuit breaker in open position (Ronis or Profalux)
Pressure switch
Accessories
Support frame (kit)
DE55736
49
Notes 0
50
Notes 0
51