The document outlines fire zone regulations and building code requirements. It defines 5 fire zones based on restrictions and required fire resistance. Buildings must meet certain construction standards depending on their location and use. All buildings are classified into 9 groups (A to I) according to their use as residential, hotels, education, industrial, storage etc. Each group has divisions that specify occupancy limits and requirements.
The document outlines fire zone regulations and building code requirements. It defines 5 fire zones based on restrictions and required fire resistance. Buildings must meet certain construction standards depending on their location and use. All buildings are classified into 9 groups (A to I) according to their use as residential, hotels, education, industrial, storage etc. Each group has divisions that specify occupancy limits and requirements.
The document outlines fire zone regulations and building code requirements. It defines 5 fire zones based on restrictions and required fire resistance. Buildings must meet certain construction standards depending on their location and use. All buildings are classified into 9 groups (A to I) according to their use as residential, hotels, education, industrial, storage etc. Each group has divisions that specify occupancy limits and requirements.
RULE 5 - REQUIREMENTS OF without fire-resistivity measures (type 1,2)
FIRE ZONE ⚫ Fire Restrictive Zone - permitted
within prescribed fire-resistivity Section 501. Fire Zones Defined measures for exterior walls of at least ⚫ Fire Zones - areas within which only two-hour fire resistivity (type 3,4,5) certain types of buildings/structures ⚫ Highly Fire Restrictive Zone - no less are permitted to be constructed than three to four-hour fire-resistive construction materials are used Section 502. Buildings Located in More throughout, including exterior walls Than One Fire Zone (type 4,5) ⚫ A building/structure which is located partly in one (1) fire zone and partly in RULE 6 - FIRE-RESISTIVE another (more highly restrictive fire REQUIREMENTS IN CONSTRUCTION zone), when more than one third (1/3) of its total floor area is located in such Section 601. Fire-Resistive Rating Defined zone. ⚫ Fire-resistive rating means the degree Section 503. Moved Buildings to which a material can withstand fire Section 504. Temporary Buildings/ as determined by generally recognized Structures and accepted testing methods ⚫ Temporary Buildings - reviewing Section 602. Fire-Resistive Time Period stands, sheds, canopies, fences Rating ⚫ restrictive and highly restrictive zones ⚫ length of time a material can - permitted for a given period of time withstand being burned which may be Section 505. Center Lines of STreets one- hour, two- hours, four- hours, etc. ⚫ The center line of adjoining street or Section 603. Fire-Resistive Standards alley may be considered an adjacent Section 604. Fire-Resistive Regulations property line. Distances shall be ⚫ The Secretary - testing of construction measured at right angles to the street materials for flame-spread or alley. characteristics, tests on fire damages, fire tests of building construction and Section 506. Restrictions on Existing materials, door assemblies and tinclad Buildings fire doors and window assemblies, the ⚫ Demolished, outside the limits, installation of fire doors and windows ⚫ Changes, alterations and repairs may and smoke and fire detectors for fire be made provided that in any 12- protective signaling system, month period, the value of the work application and use of controlled does not exceed 20% of the value of interior finish, fire-resistive protection the existing building for structural members, fireresistive ⚫ cost of such repair shall not exceed 20% walls and partitions, fire-resistive floor of the replacement cost or roof ceiling, fire-resistive Section 507. Designation of Fire Zones assemblies for protection of openings ⚫ Non-Fire Restricted Zone - permitted and fire-retardant roof coverings. RULE 7 - CLASSIFICATION AND ⚫ Group E - Business and Mercantile GENERAL REQUIREMENTS OF ALL ➢ Division 1-Gasoline filling and BUILDINGS BY USE OR OCCUPANCY service stations, storage garages and boat storage structures Section 701. Occupancy Classified ➢ Division 2 -Wholesale and retail ⚫ Group A – Residential Dwellings stores, office buildings, drinking ➢ Division 1 - single family and dining establishments (<100) occupants, single family ➢ Division 3 - Aircraft hangars and dwellings, churches, church open parking garages rectories, community facilities, ⚫ Group F - Industrial parks, playgrounds, pocket parks, ice plants, power plants, courts….. pumping plants, cold storage, ➢ Division 2 - exclusive use of non- and creameries, factories and leasing occupants not exceeding workshops 10 persons, school dormitories, ⚫ Group G - Storage & Hazardous convents, monasteries, pre- ➢ Division 1 - Storage and handling schools, elementary and high of hazardous and highly schools, provided that they do flammable material not exceed 16 classrooms…. ➢ Division 2 - dry cleaning plants, ⚫ Group B – Residentials, Hotels and paint stores, paint shops Apartments ➢ Division 3 - wood working multiple dwelling units including establishment boarding or lodging houses, ⚫ Group H - Assembly other than group I hotels, apartment buildings, row ➢ Division 1- stage and an occupant houses, convents, monasteries load of less than 1000 in the and other similar building each building. of which accommodates more ➢ Division 2- Any assembly than 10 persons. building without stage and ⚫ Group C – Education and Recreation having an occupant load of 300 used for school or day-care or more in the building. purposes, involving assemblage ➢ Division 3- Any assembly for instruction, education, or building without a stage and recreation, and not classified in having an occupant load of less Group I or in Division 1 and 2 or than 300 in the building Group H Occupancies. ➢ Division 4- Stadia, reviewing ⚫ Group D – Institutional stands, amusement park ➢ Division 1 - inmates structures not included within ➢ Division 2 - Nurseries, hospitals, Group I or in Division 1, 2, and 3 non-ambulatory, more than 5 of this Group. ➢ Division 3 -ambulatory ⚫ Group I - Assembly Occupant Load Provided, that Group D 1000 or More Occupancies shall not include buildings used ➢ with a stage and an occupant load only for private or family group dwelling of 1000 or more in the building purposes.