LEGEND :
T DATA
TWIN SOCKET
SINGLE SOCKET
POWER
CONNECTOR
FOR AC
LIGHTING SWITCH
DOWN LIGHT
F/A F/A F/A F/A
925
s SMOKE DETECTOR
A
1
AL-08
AR-76-051 SPRINKLER HEAD
1300
AL-08 LT 04 (WALL MOUNT)
TL 01A DOWN LIGHT SPRINKLER HEAD
D
PROVISION FOR ENERGY CONCRETE LOOK AC UNIT (CONCEALED)
SAVING SCREEN 1 HOMOGENEOUS TILE LT 02
FIRE ALARM BELL
C
3460
C
LIGHT FIXTURE
AR-12-465 AP
WIFI PANEL
MT 01
3
4 AR-12-465 AR-12-465 2 5mm THK STAINLESS STEEL EXIT EXIT SIGN
DIVIDING STRIP F.C.L.+ 3800 A.F.F.L. CCTV
1300
AR-12-465
3 EXHAUSTED
LOUVERS
ACCESS PANEL
ELECT. RM A.P.
F/B F/B F/B F/B
60 210 55
SC0775
?
.1 .1
? F .E F .E
1710
ST-08 TENDER ADDENDUM
ST-08
EXIT
F/C F.H
.
P.D
.
F/C F/C F.H
.
F/C
H.R.
H.R.
360
2800
LF 06
CCTV
3
LINOLEUM FLOORING LT 06
LOBBY LOUNGE
EQ
PENDANT LIGHT
SC0777
5 LT 05
LIGHT FIXTURE
FCU-6
0 AR-12-465 3 17/03/2020 TENDER ADDENDUM No.5
2 28/02/2020 TENDER ADDENDUM No.3
F/E F/E 3 F/E A.P F/E 1 14/02/2020 TENDER ADDENDUM No.2
8 AR-12-465 AR-12-465 6
0 17/01/2020 TENDER PLOT
510
AR-12-465 PT 01
EQ
PAINT FINISH REV. DATE DESCRIPTION
7 NAME DATE
DESIGNED HL 17/01/2020
ENTRANCE MATT DRAWN SL 17/01/2020
CHECKED RT 17/01/2020
APPROVED IL/KK 17/01/2020
LF 06 EXIT CLIENT
THE HONG KONG
LINOLEUM FLOORING UNIVERSITY OF SCIENCE
2180 260 50 700 50 400 50 400 1400 1400 1400 475 AND TECHNOLOGY
HKUST, CLEARWATER BAY,
2645 2000 KOWLOON, HONG KONG
T 852 2358 6421
F 852 2358 0569
E eomail@ust.hk
www.ust.hk
AC UNIT LEAD CONSULTANT, ARCHITECT, INTERIOR DESIGNER, AP
CELING TYPE LEIGH & ORANGE LTD.
801, DOREST HOUSE,
TAIKOO PLACE, 979 KING'S ROAD,
HONG KONG
T 852 2899 9000
F 852 2806 0343
E info@leighorange.com
www.leighorange.com
LAYOUT OUT PLAN & FLOOR FINISHES REFLECTED CEILING PLAN CONCEPT DESIGNER
1 1 : 25
2 1 : 25
ZAHA HADID (HONG KONG) LTD.
UNIT 2503, TAI TUNG BUILDING,
NO.8 FLEMING ROAD, WANCHAI,
HONG KONG
T 852 3425 4240
www.zaha-hadid.com
EARTHASIA LIMITED
11/F, COFCO TOWER,
262 GLOUCESTER ROAD,
CAUSEWAY BAY, HONG KONG
T 852 2559 9438 F 852 2559 9841
E info@earthasia.com.hk
www.ea-dg.com
STUDENT RESIDENCE
1. ALL BUILDING SERVICES ARE INDICATIVE FOR POSITION AND SETTING OUT ONLY. THE CONTRACTOR SHALL REFER D E VE L O PM E N T AT T H E H O N G K O N G
TO BS PACKAGE AND SPECIFICATION FOR THE DETAILS AND PROVISIONS. U N IV E R S I T Y O F S C IE N C E A N D
2. THE CONTRACTOR SHALL READ IN CONJUNCTION WITH AR-46 SERIES FOR WATERPROOFING DETAILS AND EXTENT; TECHNOLOGY
3. THE CONTRACTOR SHALL READ IN CONJUNCTION WITH AR-38 SERIES FOR THE MOVEMENT JOINT DETAILS AND
LOCATION; DRAWING TITLE
4. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE FIRE BARRIER FOR MAINTAINING THE REQUIRED FRR FOR LIFT LOBBY LAYOUT, FLOOR
ANY SEM OPENING OF BUILDING SERVICES; FINISHES AND R.C.PLAN 7/F (AL-08)
5. THE CONTRACTOR SHALL BE RESPONSIBLE TO CHECK THE ILLUMINATION LEVEL BASED ON THE LAYOUT PLANS
AND LIGHTING SCHEDULE, AND COMPLY THE REQUIREMENT OF BUILDING ENERGY CODE AND OTHER RELEVANT
STATUTORY AND BEAM PLUS REQUIREMENT;
DRAWING NO.
6. ALL FURNITURE SHALL BE FABRICATED AND MANUFACTURED OFF-SITE FOR ON-SITE INSTALLATION.
7. THE CONTRACTOR SHALL BE RESPONSIBLE TO INTEGRATE THE GRAPHIC AND SIGNAGE PACKAGE INTO THE AR-12-416
INTERIOR DESIGN FOR SHOP DRAWING SUBMISSION;
8. THE CONTRACTOR SHALL READ IN CONJUNCTION WITH AR-31, AR-32 AND AR-33 FOR THE DOORS, WINDOWS AND JOB NO. RE V .
18078 3
LOUVRES DESIGN, AND INTEGRATE AND PRODUCE SHOP DRAWING SUBMISSION
9. PROVISION TO BE MADE FOR ELECTRICAL OUTLETS TO ALL FURNITURE, FIXTURE + EQUIP REQUIRING POWER SCALE:
1 : 25
D W G . S IZ E
A0
DO NOT SCALE DRAWING. ALL DIMENSIONS SHOULD BE CHECKE ON SITE.
THE OWNERSHIP OF THE COPYRIGHT IN THIS DRAWING IS RETAINED BY THE ISSUER WHOSE CONSENT MUST BE OBTAINED BEFORE ANY USE OR REPRODUCTION OF THE DRAWING OR ANY PART THEREOF CAN BE MADE.