GRUNDFOS DATA BOOKLET

MMS6
Rewindable, submersible motors and accessories
50/60 Hz
MMS6

1. General description 3 10. Order data 38


Table of contents

MMS6 rewindable motors 3 3 x 200 V, 50 Hz, and 3 x 200-220 V, 60 Hz,


Rewindable motors 3 SF 1.0, Japan 38
High motor efficiency 3 3 x 220-230 V, 50 Hz 38
Overtemperature protection 3 3 x 380-400-415 V, 50 Hz,
Protection against upthrust 4 and 3 x 460 V, 60 Hz 39
Operation 4 3 x 380-400-415 V, 50 Hz, and 3 x 460 V, 60 Hz
(boxed up for sea freightage) 40
2. Identification 5 3 x 400 V, 50 Hz, and 3 x 400-440 V, 60 Hz,
Nameplate 5 SF 1.0, Japan 40
Type key 6 3 x 400-415 V, 50 Hz, Australia 40
3 x 460 V, 50 Hz 41
3. Operating conditions 7 3 x 500-525 V, 50 Hz, and 3 x 575 V, 60 Hz, SF 1.15
Cooling 7 41
Free convection 7 3 x 380 V, 60 Hz, SF 1.15 43
Maximum liquid temperature 7
Operating pressure 7 11. Further product documentation 44
Liquid temperature 7 WebCAPS 44
Winding temperature 8 WinCAPS 45
Voltage quality 8
Enclosure class 8

4. Construction 9
Material specification 9
Pump connection 10
Shaft and radial bearing 10
Shaft seal 10
Rotor 10
Stator 10
Thrust bearing 11
Upthrust bearing 11
Diaphragm 11
Motor liquid 11

5. Technical data 12
MMS6 (-N, -R) 12

6. Electrical data 14

7. Wiring diagram 21
Wiring diagram 21

8. Accessories 22
CUE frequency converter 22
MP 204 25
G100 gateway for communication with Grundfos
products 27
Cable termination kit, type KM 29
Mastik for flat cables 29
Cable termination kit, types M0 to M6 30
Submersible drop cable 30
Zinc anodes 31
Flow sleeves 31
Pt100 sensor 32
Pt1000 sensor 34

9. Cable sizing 36
Drop cables 36
Cable sizing 37

2
MMS6
1

1. General description

General description
MMS6 rewindable motors
Grundfos MMS6 motors are 6" rewindable,
submersible motors, available in sizes from 5.5 kW to
37 kW.
Three material versions are available:
• A cast-iron version of EN-JL1040.
• For aggressive liquids with a moderate content of
salt, an N-version of stainless steel DIN/EN 1.4401
(AISI 316) is available.
• For aggressive liquids with a higher salt content
than that of seawater and for temperatures above
15 °C, we recommend the R-version of stainless
steel DIN/EN 1.4539 (AISI 904L).
MMS6 submersible motors are designed according to
market standards. All motors are designed to fit pump
ends manufactured according to NEMA standards.
The motors are ideally suited for water supply pumps
for irrigation, groundwater regulation, pressure
boosting, industrial water transfer and similar
applications. MMS6 motors comply with the same
standards as Grundfos MS motors and can therefore
be fitted to all Grundfos SP pumps without adapters.

GrA4575
The motor production is in the hands of experts with
many years of experience within the manufacture of
motors. In order to make the time of delivery as short Fig. 1 MMS6 motor
as possible, components are manufactured for stock,
enabling rapid assembly of a few basic components
into the finished motor.
Rewindable motors
The rewindable motor design means low costs of The two-pole MMS6 motors are easily rewound.
repair of the motor in case of damage. The rewindable The stator windings are made of a special water-proof
submersible motor technology reduces the risk of hot wire of pure electrolytic copper sheathed with special
spots in the motor as the liquid inside has a uniform non-hydroscopic thermoplastic material.
contact with active parts. The motor is filled with motor The high dielectric strength properties of this material
liquid ensuring sufficient lubrication of radial bearings. allow direct contact between the windings and the
Moreover, as motors can be rewound locally, liquid for efficient cooling of the windings.
unnecessary time for transportation of the motor can
be avoided and possible periods of downtime reduced High motor efficiency
to a minimum. The design of the motor, based on few
basic components, also facilitates service and repair of The complete motor range offered by Grundfos is
the motor. characterised by high efficiency contributing to
Fitted with a sturdy Michell thrust bearing, which also improved economy of the total pump system.
functions as an upthrust bearing, all motors offer
reliable operation. Overtemperature protection
In order to achieve maximum protection of the motor
For protection against overtemperature, Grundfos
against burnout, all motors can be fitted with a Pt100
offers Pt100 and Pt1000 temperature sensors as an
or Pt1000 sensor. Combined with a relay and an
optional extra.
optional Grundfos CUE frequency converter or MP 204
motor protector, the Pt100/Pt1000 sensor provides The Pt100 and Pt1000 sensors are fitted in the motor
optimum motor protection. See Accessories, page 22. and connected via a relay, which can be connected to
the MP 204 motor protector. The temperature can be
monitored by means of an MP 204, a CU 220, a
PR5714 or a CUE.
If the temperature becomes too high, the motor will be
cut out. See Accessories, page 22.

3
1 MMS6

Protection against upthrust


General description

The MMS6 motor is fitted with an upthrust bearing


which is able to withstand the uplifting force applied to
the motor shaft.
The maximum load in connection with thrust and
upthrust appears from the table below.

Motor power
Motor type Thrust* Upthrust
[kW] (hp)

Min. Max. [N] [N]


6" 5.5 (7.5) 37 (50) 27500 6000
* Double direction of rotation (clockwise and counterclockwise).

Operation
Frequency of starts

Minimum 1 per year is recommended.


Maximum 15 per hour.
Maximum 360 per day.

4
MMS6
2

2. Identification

Identification
Nameplate

3 2 1 13 14 15 16

4
5 MMS6T30 No. 96879380 Model A SN 00000123 PC P80842 17
Phase Voltage Frequency P2 P2 SF Max. SF. C. Cos n
6 [-] [V] [Hz] [kW] [hp] [-] [A] [-] [min-1]
7 3 380 50 37 50 1.00 82.5 0.85 2835
3 400 50 37 50 1.00 80.5 0.81 2860 18
3 415 50 37 50 1.00 80.9 0.77 2870
8 3 460 60 37 50 1.15 78.2 0.82 3455
19
Liquid t max. 30°C at 0.5 m/s -80°F at 16 ft/s Connection DOL Weight: 125 kg/ 276 lb
9 20
Duty S1 PT100 pmax. 60 bar kVA code E IP68

10000002423
10 MADE IN ITALY
IEC 134
11
12

TM04 3945 0409


24 23 22 21
Fig. 2 Nameplate

Pos. Description Pos. Description


1 Pump generation (A = first generation) 13 Service factor
2 Output power [kW] and [hp] 14 Serial number
3 Product number 15 Power factor
4 Type designation 16 Production code (year and week)
5 Number of phases 17 Rated speed [min-1]
6 Supply voltage [V] 18 Rated current [A]
7 Frequency of the power supply [Hz] 19 Net weight [kg] and [lb]
8 Maximum liquid temperature at flow past the motor [°C] 20 Enclosure class
9 Motor designed for continuous operation 21 Country of origin
10 Temperature sensor (Pt100) 22 Starting method
11 CE mark 23 KVA code according to NEMA standards
12 Maximum operating pressure 24 Bar code

5
2 MMS6

Type key
Identification

Code Example MMS 6 R E S D T30

Type range
(Motor Submersible)

Motor diameter [inches]

Material
Cast iron EN JL 1040
N Stainless steel EN 1.4401 (AISI 316)
R Stainless steel EN 1.4539 (AISI 904L)

Rubber parts
NBR
E FKM

Shaft seal
Ceramics/carbon
S SiC/SiC

Motor liquid
SML-3
D Demineralised water

Maximum liquid temperature (T-code)


T30 30 °C (37 kW, PVC windings)
T35 35 °C (5.5 to 30 kW, PVC windings)
T50 50 °C (PE2/PA windings)
Txx xx °C (derating + PE2/PA windings)

6
MMS6
3

3. Operating conditions

Operating conditions
Cooling Liquid temperature
The cooling of the motor depends on the temperature Motors with PVC windings can operate at liquid
and the flow velocity of the pumped liquid past the temperatures up to 30 °C without derating.
motor. When operating in liquids at temperatures from 20 °C
To ensure sufficient cooling, the values for maximum to 43 °C, the motor must be derated according to the
temperature of the pumped liquid and its flow velocity curve below.
must be kept.
We recommend always to ensure a minimum cooling 1.1
flow of 0.15 m/s. 1.0
v=
0.9 0.8

Derating factor
m/s
Free convection 0.8
v=
0.5
m /s
Free convection is achieved when the diameter of the 0.7
v=
0.2
borehole is at least 2" (~ 50 mm) bigger than the outer m/
s

TM04 4813 2109


diameter of the motor. 0.6
The motor must always be installed above the 0.5
borehole screen. If a flow sleeve is used, the motor 30 32 34 36 38 40 42 44 46
can be placed in the screen. Temperature [°C]
Calculation of the flow velocity: Fig. 4 PVC windings, 5.5 to 30 kW

Q min 1.1
v = --------------------------------------------------- m/s
2 2
2826   D i – d A  1.0
  v=
0.9
Derating factor

0.8
Required data: v= m/
0.8 0 .5 s
v=
Qmin.: Flow rate [m3/h] 0.7 0.2
m/
s
Di: Borehole diameter [m] m/
s

TM04 4814 2109


0.6
d A: Motor diameter [m].
0.5
24 26 28 30 32 34 36 38 40 42 44 46
Temperature [°C]

Fig. 5 PVC windings, 37 kW


Motors with PE2/PA windings can operate at
temperatures up to 50 °C.
Dmotor For liquid temperatures from 35 °C to 50 °C, the
motors with PE2/PA windings can be derated
according to the curve below.
TM02 1322 3601

1.1
Dborehole
1.0
0.9 v=
Derating factor

Fig. 3 Diameter of motor and borehole 0 .8


v= m/
0.8 0 .5 s
v= m/
0 .2 s
Maximum liquid temperature 0.7
m/
s
TM04 4815 2109

0.6
Flow velocity past motor PE2/PA windings PVC windings 0.5
[m/s] [°C] [°C]*
44 46 48 50 52 54 56 58 60 62 64 66
0.2 45 30 Temperature [°C]
0.5 50 35
Fig. 6 PE2/PA windings, 5.5 to 37 kW
* The maximum liquid temperature of 37 kW motors is 5 °C lower.

Operating pressure
Maximum 60 bar.

7
3 MMS6

Winding temperature
Operating conditions

PVC windings: Maximum 70 °C.


PE2/PA windings: Maximum 90 °C.

Voltage quality
The required voltage quality for Grundfos MMS6
submersible motors, measured at the motor terminals,
is - 10 %/+ 6 % of the rated voltage during continuous
operation (including variations in the supply voltage
and losses in cables).

Enclosure class
IP68.

8
MMS6
4

4. Construction

Construction
Material specification
Cast-iron version

Version

Pos. Component Material - N R

EN EN EN
202 Shaft with rotor Stainless steel 1.4301 1.4401 1.4462
Thrust Hardened steel/
1.4125 1.4125 1.4125
203/ bearing/rotating stainless steel
206 thrust bearing
part Ceramic/carbon - - -
204 Radial bearing Carbon - - -
Cast iron/
205 NEMA flange JL1040 1.4408 1.4517
stainless steel
208a Thrust ring Stainless steel 1.4016 1.4016 1.4016
Thrust bearing
208b Stainless steel 1.4016 1.4016 1.4016
support
212 Diaphragm EPDM - - -
Cast iron/
213 End cover JL1040 1.4408 1.4517
stainless steel
216 Lock nut Steel, BN1235 - - -
216a Washer Stainless steel 1.4301 1.4301 1.4301
Thrust bearing
219 Stainless steel 1.4308 1.4308 1.4517
housing
Stator with
221 Stainless steel 1.4306 1.4404 1.4539
sleeve
222b O-ring Fibronit - - -
223b Plug Stainless steel 1.4401 1.4401 1.4539
224 O-ring NBR - - -
Shaft seal Cast iron/
226 JL1040 1.4401 1.4539
housing stainless steel
Shaft seal, Ceramic/carbon ● ● -
226a
stationary part SiC/SiC ● ● ●
Shaft seal,
226b SiC - - -
rotating part
229 Sand shield FKM - - -
231 O-ring NBR - - -
232 Lip seal ring FKM - - -
Intermediate Cast iron/
235 JL1040 1.4408 1.4517
housing stainless steel
Bearing Cast iron/
236 JL1040 1.4408 1.4517
housing, lower stainless steel
Hexagon socket
236a Steel - - -
head screw
242 Upthrust spacer PP - - - 223b
247 Screw 1.4401 1.4401 1.4539
Motor cable EPDM - - -
TM04 4951 2309

Fig. 7 Sectional drawing

9
4 MMS6

Pump connection Stator


Construction

The motor has connections according to the NEMA The stator is a wet-wound design in stainless steel to
standard MG 1-18.413. protect the motor, even in corrosive water. The stator
The cable outlet of motors for star-delta starting is design allows complete access to the winding for easy
displaced by 90 °. maintenance and rewinding. The construction of the
laminations minimises operating losses and improves
motor performance.
The motor end shield is screwed onto the stator.
A suitable centring ensures alignment of rotor and
stator.

TM04 4896 2209


Fig. 8 Pump connection

Shaft and radial bearing


The stainless-steel splined shaft end complies with
ANSI B92.1, 1970, class 5. 15-teeth module shaft.
Pressure angle 30 °.
The bearing system is a stainless-steel shaft against
carbon bearing rings.

Shaft seal
The mechanical shaft seal is available in two variants:
ceramic/carbon and SiC/SiC. SiC/SiC is according to
DIN 24960.
The highly wear-resistant and durable material
ensures tightness and thus limited replacement of the
motor liquid. This is important when the pumped liquid
contains sand.
Together with the shaft seal housing, the sand shield
forms a labyrinth seal, which during normal operating
conditions prevents sand particles from entering the
shaft seal.
The double shaft seal consists of a rubber lip seal and
a mechanical seal. The double shaft seal protects the
motor from abrasive particles.

Rotor
The rotor is a squirrel-cage rotor with copper bars
brazed to the short-circuit rings with a silver alloy.
The rotor is dynamically balanced for smooth and
vibration-free operation.

10
MMS6
4
Thrust bearing Rotating bearing part

Construction
The Michell/Kingsbury type of water-lubricated thrust To prolong the bearing life, the rotating part with a
bearing is very simple and most efficient. larger surface is made of soft carbon material.
The carbon disk is polished for optimum surface finish.
The thrust capacity of the bearings is in accordance
with NEMA standards for submersible motors, where Stationary bearing part
these are applicable. See fig. 9. The stationary part is made of tempered stainless
steel. This segmented component is cast as a
one-in-all cost-effective unit. By design, each pad
becomes flexible as required for good functionality.
The segmented surface is finally polished to a
specially designed shape.

Upthrust bearing
The PP upthrust spacers above the rotating bearing
part prevent motor damage during transportation or in
case of upthrust.
The upthrust bearing is an integrated part of the thrust
bearing.

Diaphragm
The diaphragm is fitted between the stator and the
motor end shield. The diaphragm ensures that volume
changes due to temperature changes can be
accommodated by the motor liquid without effecting
the pumped liquid.

Motor liquid
The motor is factory-filled with Grundfos motor liquid,
type SML-3, which is frost-proof down to -20 °C.
Corrosion protection
The motor liquid protects metals and alloys in the
equipment against all types of corrosion. The
combination of low toxicity and FDA-approved
ingredients with a high level of corrosion protection
makes Grundfos motor liquid unique in the market.
The anti-corrosion performance is demonstrated
according to ASTM D 1384.
TM04 4952 2309

Compatibility and mixability


The motor liquid is compatible with most other heat
transfer fluids based on mono-propylene glycol.
It should only be mixed with clean water. The motor
Fig. 9 Thrust bearing liquid is also available as a dilution mixed with the
proper amount of purified water.
Pos. Description Toxicity and safety
206 Rotating bearing part The motor liquid consists of FDA-approved
216a Washer components for heat-transfer fluids with incidental food
216 Ring nut contact. Neither the concentration of the motor liquid
203 Stationary bearing part nor any dilution is classified according to the European
219 Thrust bearing housing Dangerous Preparations Directive.
208b Thrust bearing support
224 O-ring
212 Diaphragm
213 Motor end shield

11
5 MMS6

5. Technical data
Technical data

MMS6 (-N, -R)

TM04 4830 2109


Motor power
P2 L Weight Shipping volume
[mm] [kg] [m3]
[kW] [hp]
5.5 7.5 807 50 0.085
7.5 10 837 53 0.085
9.2 12 867 55 0.085
11 15 897 60 0.085
13 18 927 65 0.085
15 20 997 77 0.085
18.5 25 1057 83 0.085
22 30 1087 95 0.085
26 35 1157 105 0.085
26 Japan - 1212 110 0.099
30 40 1212 110 0.099
30 USA 40 1212 110 0.204
30 Japan - 1312 120 0.099
37 50 1312 120 0.099
37 USA 50 1312 120 0.204

12
MMS6
5
Cables Cable length:

Technical data
The MMS6 motors are connected by means of four • 5.5 and 26 kW: 5 m
single-core cables, approved for drinking water. • 30 and 37 kW: 8 m.
All cables are round. Note: Sizing of the motor cable requires that it is
The cable outlet of motors for star-delta starting is submerged in water. For longer cables and cable
displaced by 90 °. connection for extension, see 8. Accessories, page 22.
Being an integrated part of the motor, the motor cable The MMS6 motors have an integrated earth cable.
cannot be fitted or removed once the motor is
assembled.

Cross-section [mm 2]

Motor power 3 x 200 V, 50 Hz 3 x 380-415 V, 50 Hz 3 x 400 V, 50 Hz


P2 3 x 220-230 V, 50 Hz 3 x 400-415 V, 50 Hz
3 x 200-220 V, 60 Hz 3 x 460 V, 60 Hz 3 x 400-440 V, 60 Hz

DOL SD DOL SD DOL SD DOL SD DOL SD

[kW] [hp] 4x1 8x1 4x1 8x1 4x1 8x1 4x1 8x1 4x1 8x1
5.5 7.5 - - 6 - 6 - - - - -
7.5 10 - - 6 - 6 - - - - -
9.2 12 - - 6 - 6 - - - - -
11 15 - - 6 - 6 6 - - - -
13 18 - - 6 - 6 6 - - - -
15 20 - - 6 - 6 6 - - - -
18.5 25 - - 10 - 6 6 - - - -
22 30 - - 10 - 6 6 - - - -
26 35 - 6 10 - 6 6 - 6 - -
30 40 - 6 16 - 10 6 - 6 10 -
37 50 - - - 10 10 6 - - 10 -

Cross-section [mm2]

Motor power 3 x 500-525 V, 50 Hz


P2 3 x 460 V, 50 Hz 3 x 220-230 V, 60 Hz 3 x 380 V, 60 Hz
3 x 575 V, 60 Hz

DOL SD DOL SD DOL SD DOL SD

[kW] [hp] 4x1 8x1 4x1 8x1 4x1 8x1 4x1 8x1
5.5 7.5 - - - 6 - 6 -
7.5 10 6 - - 6 - 6 -
9.2 12 6 - 6 - 6 - 6 -
11 15 6 - 6 - 6 - 6 -
13 18 6 - 6 - 6 - 6 -
15 20 6 - 6 - 6 - 6 -
18.5 25 6 - 6 - 10 - 6 -
22 30 6 - 6 - 10 - 6 -
26 35 6 - 6 - 16 - 10 -
30 40 10 - 10 - 16 - 10 -
37 50 10 - 10 - - 10 10 -

Outer dimensions

Cross-section Maximum outer dimension


Type of cable
[mm2] [mm]
6 8.1
10 Round 8.8
16 10.3

13
6 MMS6

6. Electrical data
Electrical data

The tables below contain the following data among others:

Abbreviation Description
T-code T-code refers to the maximum liquid temperature. See Type key, page 6.
BT Breakdown Torque
LRT Locked-Rotor Torque
LRC Locked-Rotor Current

3 x 200 V, 50 Hz, Japan

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T50 26 116 0.69 0.80 0.84 82 83 81 2850 216 154 460 27.5 -
T50 30 134 0.68 0.79 0.84 82 83 82 2850 265 174 505 27.5 -

3 x 200 V, 60 Hz, SF 1.0, Japan

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T50 26 118 0.77 0.82 0.85 79 81 77 3410 190 130 405 27.5 H
T50 30 135 0.78 0.82 0.85 79 82 78 3420 230 140 440 27.5 H

3 x 220 V, 60 Hz, SF 1.0, Japan

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T50 26 106 0.71 0.80 0.84 82 83 81 3460 234 154 505 27.5 H
T50 30 120 0.71 0.80 0.84 83 83 81 3470 285 172 550 27.5 H

3 x 220 V, 50 Hz

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T35 5.5 26.0 0.66 0.75 0.80 71 75 75 2840 180 80 320 27.5 -
T35 7.5 34.5 0.65 0.75 0.80 74 77 76 2840 180 80 330 27.5 -
T35 9.2 41.5 0.65 0.76 0.81 75 78 77 2840 180 90 340 27.5 -
T35 11 49.5 0.59 0.71 0.78 76 79 79 2850 210 100 370 27.5 -
T35 13 56.5 0.63 0.75 0.81 78 81 80 2840 200 100 370 27.5 -
T35 15 63.0 0.65 0.76 0.82 80 82 82 2850 220 110 400 27.5 -
T35 18.5 76.5 0.68 0.79 0.83 81 82 81 2840 200 110 390 27.5 -
T35 22 89.5 0.68 0.79 0.83 83 84 82 2850 250 180 490 27.5 -
T35 26 106 0.63 0.76 0.82 82 84 83 2870 234 206 535 27.5 -
T35 30 122 0.69 0.80 0.84 83 83 81 2840 208 152 440 27.5 -
T30 37 148 0.66 0.78 0.84 83 84 82 2850 270 192 510 27.5 -
T50 5.5 26.5 0.67 0.77 0.81 70 73 72 2830 170 70 300 27.5 -
T50 7.5 35.0 0.67 0.77 0.82 72 75 73 2830 170 80 310 27.5 -
T50 9.2 41.5 0.66 0.77 0.82 74 77 75 2830 170 80 320 27.5 -
T50 11 50.0 0.61 0.73 0.81 74 77 77 2850 190 90 350 27.5 -
T50 13 57.0 0.65 0.77 0.82 77 79 78 2830 190 90 350 27.5 -
T50 15 63.5 0.66 0.77 0.82 79 81 80 2840 200 110 390 27.5 -
T50 18.5 77.0 0.69 0.79 0.84 80 81 80 2840 200 100 380 27.5 -
T50 22 90.0 0.69 0.79 0.84 82 83 81 2850 244 170 475 27.5 -
T50 26 108 0.64 0.76 0.82 82 83 82 2870 226 196 520 27.5 -
T50 30 124 0.70 0.81 0.85 82 82 80 2830 202 144 430 27.5 -
T50 37 150 0.68 0.80 0.86 82 82 80 2830 246 168 475 27.5 -

14
MMS6
6
3 x 230 V, 50 Hz

Electrical data
Motor Cos φ Efficiency (η)
I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T35 5.5 25.0 0.61 0.72 0.78 71 75 76 2860 190 90 350 27.5 -
T35 7.5 33.5 0.59 0.71 0.78 72 76 77 2860 200 90 350 27.5 -
T35 9.2 40.5 0.59 0.71 0.78 74 77 78 2860 200 90 360 27.5 -
T35 11 50.0 0.53 0.66 0.74 74 78 79 2870 230 110 380 27.5 -
T35 13 56.0 0.57 0.69 0.77 77 80 80 2860 220 110 390 27.5 -
T35 15 62.5 0.58 0.71 0.79 79 82 82 2860 240 120 430 27.5 -
T35 18.5 75.0 0.61 0.75 0.81 80 82 82 2850 230 120 420 27.5 -
T35 22 87.0 0.61 0.74 0.81 82 84 83 2870 280 198 530 27.5 -
T35 26 106 0.57 0.70 0.78 81 83 83 2880 260 226 560 27.5 -
T35 30 118 0.63 0.76 0.82 82 83 82 2860 230 166 475 27.5 -
T30 37 148 0.59 0.72 0.81 82 84 83 2860 300 212 540 27.5 -
T50 5.5 25.0 0.63 0.73 0.79 69 73 73 2860 180 80 330 27.5 -
T50 7.5 33.5 0.61 0.73 0.80 71 75 75 2850 190 90 340 27.5 -
T50 9.2 40.5 0.60 0.72 0.80 73 76 76 2850 190 90 350 27.5 -
T50 11 49.5 0.55 0.69 0.77 72 76 77 2860 210 100 370 27.5 -
T50 13 56.0 0.59 0.72 0.80 75 78 78 2850 210 100 370 27.5 -
T50 15 62.5 0.60 0.73 0.80 77 80 80 2860 230 120 410 27.5 -
T50 18.5 75.0 0.63 0.75 0.82 79 81 81 2850 220 120 410 27.5 -
T50 22 87.5 0.63 0.75 0.82 82 83 82 2870 270 188 515 27.5 -
T50 26 106 0.57 0.71 0.79 80 83 82 2880 250 216 545 27.5 -
T50 30 118 0.64 0.77 0.83 81 83 81 2850 224 160 465 27.5 -
T50 37 148 0.61 0.75 0.83 80 82 81 2850 270 186 505 27.5 -

3 x 380 V, 50 Hz

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T35 5.5 14.8 0.66 0.75 0.79 72 75 75 2850 180 80 320 27.5 -
T35 7.5 19.8 0.65 0.75 0.80 74 77 76 2840 180 80 330 27.5 -
T35 9.2 23.6 0.67 0.77 0.82 76 78 77 2830 170 80 320 27.5 -
T35 11 28.0 0.65 0.76 0.82 76 78 77 2830 180 90 340 27.5 -
T35 13 32.5 0.69 0.80 0.82 79 79 79 2830 190 100 360 27.5 -
T35 15 37.0 0.66 0.78 0.83 77 79 78 2840 200 110 390 27.5 -
T35 18.5 44.5 0.67 0.78 0.83 80 82 80 2840 220 120 410 27.5 -
T35 22 52.0 0.65 0.77 0.82 82 83 82 2860 268 192 515 27.5 -
T35 26 61.5 0.65 0.76 0.82 83 84 83 2860 236 212 540 27.5 -
T35 30 69.8 0.68 0.79 0.83 84 84 83 2850 222 162 460 27.5 -
T30 37 86.0 0.68 0.80 0.84 83 84 82 2840 250 170 470 27.5 -
T50 5.5 15.2 0.67 0.77 0.81 70 73 72 2830 170 70 300 27.5 -
T50 7.5 20.0 0.66 0.77 0.81 72 75 74 2830 170 80 310 27.5 -
T50 9.2 24.0 0.69 0.79 0.82 75 77 75 2820 160 80 310 27.5 -
T50 11 28.5 0.65 0.77 0.82 75 78 76 2830 180 90 340 27.5 -
T50 13 33.0 0.65 0.77 0.82 76 78 77 2830 190 90 350 27.5 -
T50 15 37.0 0.66 0.78 0.83 77 79 78 2840 200 110 390 27.5 -
T50 18.5 45.0 0.68 0.79 0.84 79 81 79 2830 200 110 380 27.5 -
T50 22 52.5 0.66 0.78 0.83 81 82 81 2860 268 178 495 27.5 -
T50 26 62.0 0.67 0.78 0.84 81 82 80 2850 216 184 500 27.5 -
T50 30 71.0 0.70 0.81 0.85 82 82 80 2830 206 150 435 27.5 -
T50 37 87.0 0.69 0.80 0.85 82 83 80 2830 240 162 455 27.5 -

15
6 MMS6

3 x 400 V, 50 Hz
Electrical data

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T35 5.5 14.4 0.60 0.71 0.77 71 75 76 2870 200 90 350 27.5 -
T35 7.5 19.2 0.59 0.71 0.78 72 76 77 2860 200 90 360 27.5 -
T35 9.2 22.8 0.61 0.73 0.79 75 78 78 2850 200 90 350 27.5 -
T35 11 27.5 0.58 0.71 0.79 74 78 78 2860 210 100 370 27.5 -
T35 13 32.0 0.63 0.75 0.79 77 79 79 2850 220 110 380 27.5 -
T35 15 36.5 0.59 0.72 0.80 76 79 79 2860 230 120 420 27.5 -
T35 18.5 43.5 0.60 0.72 0.80 79 81 81 2860 250 140 450 27.5 -
T35 22 51.5 0.57 0.70 0.79 81 83 83 2880 300 214 550 27.5 -
T35 26 61.0 0.57 0.70 0.78 81 83 83 2880 265 236 570 27.5 -
T35 30 68.2 0.61 0.73 0.81 83 84 84 2870 250 180 500 27.5 -
T30 37 84.5 0.60 0.73 0.81 82 84 83 2860 280 190 505 27.5 -
T50 5.5 14.4 0.63 0.73 0.79 69 73 73 2860 190 80 340 27.5 -
T50 7.5 19.4 0.60 0.72 0.79 71 75 75 2860 190 90 350 27.5 -
T50 9.2 23.0 0.63 0.75 0.81 74 77 76 2850 190 90 340 27.5 -
T50 11 27.5 0.58 0.71 0.79 73 77 77 2860 200 100 370 27.5 -
T50 13 32.5 0.57 0.70 0.79 74 77 77 2850 210 110 380 27.5 -
T50 15 36.5 0.59 0.72 0.80 76 79 79 2860 230 120 420 27.5 -
T50 18.5 43.5 0.61 0.74 0.82 78 80 80 2850 220 120 420 27.5 -
T50 22 51.5 0.58 0.72 0.80 80 82 81 2880 300 200 530 27.5 -
T50 26 61.0 0.59 0.72 0.81 79 82 81 2870 242 208 535 27.5 -
T50 30 68.5 0.63 0.76 0.82 81 83 81 2850 232 168 480 27.5 -
T50 37 84.5 0.61 0.75 0.82 81 83 82 2860 270 180 495 27.5 -

3 x 415 V, 50 Hz

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T35 5.5 14.2 0.57 0.68 0.75 69 75 76 2880 220 100 370 27.5 -
T35 7.5 19.2 0.55 0.67 0.75 71 76 77 2870 220 100 370 27.5 -
T35 9.2 22.6 0.57 0.69 0.77 73 78 78 2860 210 100 370 27.5 -
T35 11 27.5 0.54 0.67 0.76 72 77 78 2870 220 110 380 27.5 -
T35 13 32.0 0.57 0.71 0.75 76 79 79 2860 230 120 390 27.5 -
T35 15 37.0 0.53 0.67 0.76 74 78 79 2870 250 130 430 27.5 -
T35 18.5 44.0 0.54 0.68 0.77 77 81 81 2870 270 150 460 27.5 -
T35 22 52.5 0.51 0.65 0.75 79 82 82 2890 325 234 560 27.5 -
T35 26 62.0 0.51 0.65 0.74 80 83 83 2890 290 255 585 27.5 -
T35 30 68.2 0.55 0.69 0.77 82 84 84 2880 270 196 515 27.5 -
T30 37 85.0 0.55 0.69 0.78 80 83 83 2870 305 206 520 27.5 -
T50 5.5 14.2 0.58 0.70 0.77 68 73 74 2870 200 90 360 27.5 -
T50 7.5 19.2 0.56 0.69 0.77 70 74 75 2870 210 100 360 27.5 -
T50 9.2 22.6 0.58 0.71 0.78 72 76 77 2860 200 100 360 27.5 -
T50 11 28.0 0.54 0.67 0.76 72 76 77 2870 220 110 380 27.5 -
T50 13 33.0 0.52 0.66 0.75 71 76 77 2870 230 120 390 27.5 -
T50 15 37.0 0.53 0.67 0.76 74 78 79 2870 250 130 430 27.5 -
T50 18.5 44.0 0.56 0.69 0.78 76 80 80 2860 240 130 430 27.5 -
T50 22 52.5 0.53 0.67 0.76 78 81 81 2890 325 216 545 27.5 -
T50 26 61.5 0.53 0.68 0.77 78 81 81 2880 265 224 550 27.5 -
T50 30 68.5 0.57 0.71 0.80 80 82 81 2870 250 182 495 27.5 -
T50 37 85.0 0.56 0.69 0.79 80 82 82 2870 290 196 510 27.5 -

16
MMS6
6
3 x 460 V, 60 Hz, SF 1.15

Electrical data
Motor Current Motor Cos φ Efficiency (η)
kVA
n BT LRT LRC Thrust
Full load Full Max. Max. load (P1) Full Full Max. code
T-code

Max. load
(P2) load load incl. SF load load load

[kW] [hp] [A] [A] [kW] [%] [%] [min-1] [%] [%] [%] [kN] [lbf]
T35 5.5 7.5 13.0 14.4 8.50 0.76 0.78 74 75 3460 200 80 340 27.5 6182 F
T35 7.5 10 17.2 19.0 11.4 0.76 0.78 76 77 3460 200 80 350 27.5 6182 F
T35 9.2 12 20.2 22.6 13.6 0.78 0.80 78 78 3440 190 80 350 27.5 6182 E
T35 11 15 24.2 27.0 16.2 0.77 0.80 78 78 3450 210 90 370 27.5 6182 F
T35 13 20 31.0 31.0 21.8 0.80 0.80 80 80 3450 220 100 390 27.5 6182 E
T35 15 20 32.0 35.5 21.8 0.78 0.81 80 80 3460 230 110 430 27.5 6182 G
T35 18.5 25 38.0 42.5 26.0 0.79 0.81 82 82 3450 260 120 460 27.5 6182 E
T35 22 30 45.0 47.5 30.0 0.77 0.79 84 84 3490 320 220 615 27.5 6182 J
T35 26 35 53.0 59.0 35.5 0.77 0.80 84 84 3470 270 222 605 27.5 6182 J
T35 30 40 58.8 66.1 41.0 0.80 0.82 85 84 3460 255 166 520 27.5 6182 H
T30 37 50 73.0 82.0 51.0 0.80 0.82 84 84 3450 285 176 530 27.5 6182 H
T50 5.5 7.5 13.0 14.6 8.80 0.78 0.79 72 73 3440 190 80 330 27.5 6182 E
T50 7.5 10 17.2 19.2 11.6 0.77 0.80 75 75 3450 190 80 350 27.5 6182 F
T50 9.2 12 20.2 22.8 14.0 0.79 0.81 77 76 3440 190 80 340 27.5 6182 E
T50 11 15 24.4 27.0 16.4 0.77 0.80 78 78 3450 210 90 370 27.5 6182 F
T50 13 18 28.5 32.0 19.2 0.77 0.80 78 78 3450 210 100 390 27.5 6182 F
T50 15 20 32.0 35.5 21.8 0.78 0.81 80 80 3460 230 110 430 27.5 6182 G
T50 18.5 25 38.0 42.5 26.5 0.80 0.82 81 81 3450 230 110 430 27.5 6182 F
T50 22 30 45.0 47.5 30.5 0.78 0.80 83 83 3480 320 206 595 27.5 6182 J
T50 26 35 53.0 59.0 36.5 0.79 0.82 83 82 3470 250 200 575 27.5 6182 J
T50 30 40 59.0 67.0 42.0 0.81 0.83 83 82 3450 240 156 500 27.5 6182 G
T50 37 50 73.0 82.0 51.5 0.81 0.83 83 83 3450 275 168 520 27.5 6182 H

3 x 400 V, 50 Hz, Japan

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T50 26 58.0 0.69 0.79 0.84 82 83 81 2850 228 164 480 27.5 -
T50 30 66.5 0.67 0.78 0.83 82 83 82 2850 280 188 530 27.5 -

3 x 400 V, 60 Hz, SF 1.0, Japan

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T50 26 58 0.77 0.82 0.85 79 81 77 3410 195 130 420 27.5 H
T50 30 68 0.78 0.83 0.86 80 82 79 3425 240 150 460 27.5 H

3 x 440 V, 60 Hz, SF 1.0, Japan

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T50 26 52.5 0.71 0.80 0.83 82 83 81 3460 246 162 520 27.5 H
T50 30 60.0 0.70 0.80 0.83 83 83 81 3470 300 184 570 27.5 H

3 x 400 V, 50 Hz, Australia

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T50 30 68 0.73 0.82 0.86 83 82 79 2820 190 140 410 27.5 -
T50 37 83 0.74 0.83 0.87 83 82 79 2810 230 170 450 27.5 -

17
6 MMS6

3 x 415 V, 50 Hz, Australia


Electrical data

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T50 30 65.0 0.69 0.80 0.85 82 82 80 2840 210 152 445 27.5 -
T50 37 79.0 0.69 0.81 0.86 82 83 80 2830 255 180 490 27.5 -

3 x 460 V, 50 Hz

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T35 7.5 16.6 0.61 0.73 0.79 73 76 77 2850 190 90 340 27.5 -
T35 9.2 19.8 0.65 0.76 0.81 74 77 76 2840 180 80 330 27.5 -
T35 11 23.4 0.63 0.75 0.81 75 78 77 2840 190 90 350 27.5 -
T35 13 27.5 0.61 0.73 0.81 76 79 78 2840 200 100 370 27.5 -
T35 15 30.5 0.65 0.77 0.82 79 81 80 2840 210 110 400 27.5 -
T35 18.5 37.5 0.63 0.76 0.82 78 80 80 2850 220 120 410 27.5 -
T35 22 43.5 0.63 0.76 0.82 81 82 81 2850 270 190 515 27.5 -
T35 26 52.0 0.63 0.75 0.82 81 82 81 2850 234 200 530 27.5 -
T35 30 58.0 0.68 0.79 0.84 82 83 81 2850 220 158 460 27.5 -
T30 37 71.5 0.64 0.77 0.82 83 84 83 2850 270 186 500 27.5 -
T50 7.5 16.8 0.61 0.73 0.80 71 74 74 2850 190 90 340 27.5 -
T50 9.2 19.8 0.65 0.76 0.81 74 77 76 2840 180 80 330 27.5 -
T50 11 23.4 0.63 0.75 0.81 75 78 77 2840 190 90 350 27.5 -
T50 13 27.5 0.63 0.75 0.82 75 78 77 2840 190 100 360 27.5 -
T50 15 31.0 0.62 0.75 0.81 77 80 79 2850 220 110 410 27.5 -
T50 18.5 37.5 0.63 0.76 0.82 78 80 80 2850 220 120 410 27.5 -
T50 22 43.5 0.63 0.76 0.82 81 82 81 2850 270 190 515 27.5 -
T50 26 52.0 0.64 0.77 0.83 79 81 79 2850 218 182 500 27.5 -
T50 30 59.0 0.69 0.80 0.85 81 82 79 2850 208 148 440 27.5 -
T50 37 72.5 0.66 0.79 0.84 81 82 80 2850 250 166 470 27.5 -

3 x 500 V, 50 Hz

Motor Cos φ Efficiency (η)


I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T50 9.2 18.6 0.61 0.74 0.81 72 75 75 2850 190 90 350 27.5 -
T50 11 21.8 0.64 0.75 0.81 74 77 76 2840 190 90 350 27.5 -
T50 13 25.0 0.62 0.75 0.81 76 78 78 2840 200 100 370 27.5 -
T50 15 28.0 0.65 0.77 0.82 77 80 79 2840 210 110 390 27.5 -
T50 18.5 34.5 0.65 0.77 0.83 78 80 79 2840 210 110 400 27.5 -
T50 22 39.5 0.69 0.80 0.84 82 82 80 2850 242 170 475 27.5 -
T50 26 47.0 0.67 0.79 0.84 81 82 80 2850 216 184 500 27.5 -
T50 30 54.5 0.67 0.79 0.84 80 81 79 2850 210 150 445 27.5 -
T50 37 66.5 0.66 0.78 0.85 81 82 80 2850 265 186 505 27.5 -

18
MMS6
6
3 x 525 V, 50 Hz

Electrical data
Motor Cos φ Efficiency (η)
I1/1 n BT LRT LRC Thrust kVA code
P2 50 % 75 % 100 % 50 % 75 % 100 %
T-code
[kW] [A] [%] [%] [%] [min-1] [%] [%] [%] [kN]
T50 9.2 18.6 0.55 0.69 0.77 70 74 75 2870 210 100 370 27.5 -
T50 11 21.4 0.57 0.70 0.78 72 76 77 2860 210 100 370 27.5 -
T50 13 25.0 0.55 0.69 0.77 73 77 78 2860 220 110 390 27.5 -
T50 15 28.0 0.58 0.71 0.79 76 79 79 2860 230 120 420 27.5 -
T50 18.5 34.0 0.58 0.71 0.80 76 79 79 2860 230 120 420 27.5 -
T50 22 38.5 0.63 0.75 0.82 81 82 81 2870 270 190 515 27.5 -
T50 26 46.0 0.60 0.73 0.81 80 82 81 2870 240 206 535 27.5 -
T50 30 53.5 0.59 0.73 0.82 79 81 80 2860 234 166 475 27.5 -
T50 37 66.0 0.57 0.72 0.81 79 81 81 2860 300 208 530 27.5 -

3 x 575 V, 60 Hz, SF 1.15

Motor Current Motor Cos φ Efficiency (η)


kVA
n BT LRT LRC Thrust
Full load Full Max. Max. load (P1) Full Full Max. code
T-code

Max. load
(P2) load load incl. SF load load load

[kW] [hp] [A] [A] [kW] [%] [%] [min-1] [%] [%] [%] [kN] [lbf]
T50 9.2 12 16.4 18.4 14.2 0.78 0.81 76 76 3450 190 80 350 27.5 6182 E
T50 11 15 19.0 21.4 16.6 0.80 0.82 77 77 3440 190 80 350 27.5 6182 E
T50 13 18 22.0 24.8 19.2 0.80 0.82 79 78 3440 200 90 370 27.5 6182 E
T50 15 20 24.6 28.0 21.8 0.81 0.83 80 79 3440 210 100 400 27.5 6182 F
T50 18.5 25 30.0 34.0 27.0 0.82 0.83 80 80 3440 210 100 410 27.5 6182 F
T50 22 30 34.0 39.0 31.0 0.82 0.84 82 81 3440 248 162 495 27.5 6182 G
T50 26 35 40.5 46.5 37.0 0.82 0.84 82 81 3450 222 178 525 27.5 6182 H
T50 30 40 47.0 53.5 43.0 0.82 0.84 81 80 3440 218 142 465 27.5 6182 H
T50 37 50 57.0 65.0 52.5 0.83 0.85 82 81 3440 280 178 530 27.5 6182 H

3 x 220 V, 60 Hz, SF 1.15

Motor Current Motor Cos φ Efficiency (η)


kVA
n BT LRT LRC Thrust
Full load Full Max. Max. load (P1) Full Full Max. code
T-code

Max. load
(P2) load load incl. SF load load load

[kW] [hp] [A] [A] [kW] [%] [%] [min-1] [%] [%] [%] [kN] [lbf]
T35 5.5 7.5 27.0 30.5 8.55 0.77 0.79 74 74 3450 190 80 340 27.5 6182 F
T35 7.5 10 36.0 40.0 11.4 0.76 0.79 76 76 3450 200 80 350 27.5 6182 F
T35 9.2 12 42.0 47.0 13.6 0.78 0.80 78 78 3440 190 80 350 27.5 6182 F
T35 11 15 50.5 56.0 15.8 0.76 0.79 80 80 3450 210 90 370 27.5 6182 G
T35 13 18 57.5 64.5 18.6 0.78 0.80 81 81 3440 210 90 380 27.5 6182 F
T35 15 20 65.5 73.5 21.2 0.78 0.81 82 82 3450 230 110 420 27.5 6182 G
T35 18.5 25 78.5 88.5 26.0 0.81 0.82 82 81 3440 220 100 410 27.5 6182 F
T35 22 30 90.5 102 30.5 0.81 0.83 83 83 3460 265 174 525 27.5 6182 H
T35 26 35 106 120 35.5 0.81 0.83 84 84 3460 228 182 535 27.5 6182 H
T35 30 40 120 138 41.0 0.82 0.84 84 84 3440 224 148 470 27.5 6182 G
T30 37 50 152 172 51.0 0.81 0.84 84 83 3450 280 182 545 27.5 6182 H
T50 5.5 7.5 27.0 30.5 8.70 0.78 0.80 72 72 3440 180 70 330 27.5 6182 F
T50 7.5 10 36.0 40.5 11.6 0.77 0.80 75 75 3450 190 80 340 27.5 6182 F
T50 9.2 12 42.0 48.0 13.8 0.80 0.81 76 76 3.430 180 80 330 27.5 6182 F
T50 11 15 50.5 56.5 16.2 0.78 0.80 78 78 3450 200 90 360 27.5 6182 F
T50 13 18 57.5 64.5 18.8 0.79 0.82 80 79 3440 200 90 370 27.5 6182 F
T50 15 20 65.5 73.5 21.4 0.79 0.81 81 81 3450 230 100 420 27.5 6182 G
T50 18.5 25 79.0 89.0 26.5 0.81 0.83 81 80 3440 210 100 400 27.5 6182 F
T50 22 30 90.5 104 30.5 0.82 0.83 83 82 3450 260 166 515 27.5 6182 H
T50 26 35 106 122 36.5 0.82 0.84 82 81 3450 218 172 515 27.5 6182 G
T50 30 40 122 140 42.0 0.83 0.85 83 81 3.430 208 136 445 27.5 6182 F
T50 37 50 152 172 51.5 0.82 0.84 83 82 3450 275 174 530 27.5 6182 G

19
6 MMS6

3 x 230 V, 60 Hz, SF 1.15


Electrical data

Motor Current Motor Cos φ Efficiency (η)


kVA
n BT LRT LRC Thrust
Full load Full Max. Max. load (P1) Full Full Max. code
T-code

Max. load
(P2) load load incl. SF load load load

[kW] [hp] [A] [A] [kW] [%] [%] [min-1] [%] [%] [%] [kN] [lbf]
T35 5.5 7.5 26.5 29.5 8.55 0.74 0.77 74 75 3470 210 80 360 27.5 6182 F
T35 7.5 10 36.0 39.5 11.4 0.72 0.76 76 77 3470 220 90 370 27.5 6182 F
T35 9.2 12 42.0 46.0 13.6 0.75 0.78 78 79 3460 210 90 370 27.5 6182 F
T35 11 15 51.0 56.0 15.8 0.72 0.75 80 80 3470 230 100 390 27.5 6182 G
T35 13 18 57.5 63.5 18.6 0.74 0.78 81 81 3460 230 100 400 27.5 6182 F
T35 15 20 66.5 73.0 21.2 0.74 0.77 81 82 3470 260 120 450 27.5 6182 G
T35 18.5 25 78.5 87.0 26.0 0.77 0.80 82 82 3460 240 110 440 27.5 6182 F
T35 22 30 90.0 100 30.5 0.78 0.81 84 83 3470 295 192 565 27.5 6182 H
T35 26 35 106 118 35.5 0.78 0.81 84 84 3470 250 202 575 27.5 6182 H
T35 30 40 118 132 41.0 0.80 0.82 85 84 3460 248 162 510 27.5 6182 G
T30 37 50 154 170 51.0 0.77 0.81 84 84 3470 310 200 575 27.5 6182 H
T50 5.5 7.5 26.5 29.5 8.70 0.76 0.78 73 73 3460 200 80 350 27.5 6182 F
T50 7.5 10 36.0 39.5 11.6 0.74 0.77 75 75 3470 210 90 370 27.5 6182 F
T50 9.2 12 41.5 46.5 13.8 0.77 0.79 77 77 3450 200 80 360 27.5 6182 F
T50 11 15 51.0 56.0 16.2 0.73 0.77 78 79 3460 220 90 390 27.5 6182 F
T50 13 18 57.5 63.5 18.8 0.76 0.79 80 80 3450 220 100 390 27.5 6182 F
T50 15 20 66.5 73.0 21.4 0.75 0.78 81 81 3470 250 120 440 27.5 6182 G
T50 18.5 25 78.5 87.5 26.5 0.78 0.81 81 81 3460 230 110 430 27.5 6182 F
T50 22 30 90.0 100 30.5 0.78 0.81 83 83 3470 285 184 550 27.5 6182 H
T50 26 35 106 118 36.5 0.79 0.82 83 82 3470 242 190 555 27.5 6182 G
T50 30 40 118 134 42.0 0.81 0.83 83 82 3450 230 150 485 27.5 6182 F
T50 37 50 154 170 51.5 0.78 0.81 83 83 3460 305 192 560 27.5 6182 G

3 x 380 V, 60 Hz, SF 1.15

Motor Current Motor Cos φ Efficiency (η)


kVA
n BT LRT LRC Thrust
Full load Full Max. Max. load (P1) Full Full Max. code
T-code

Max. load
(P2) load load incl. SF load load load

[kW] [hp] [A] [A] [kW] [%] [%] [min-1] [%] [%] [%] [kN] [lbf]
T35 5.5 7.5 15.6 17.4 8.55 0.77 0.79 74 75 3450 190 80 340 27.5 6182 E
T35 7.5 10 20.8 23.2 11.4 0.76 0.79 76 76 3450 200 80 350 27.5 6182 F
T35 9.2 12 24.2 27.0 13.6 0.78 0.80 78 78 3440 190 80 350 27.5 6182 E
T35 11 15 30.0 33.0 16.2 0.76 0.79 78 78 3450 210 90 380 27.5 6182 F
T35 13 18 34.5 38.0 19.0 0.77 0.79 79 80 3450 220 100 390 27.5 6182 F
T35 15 20 38.5 43.0 21.6 0.78 0.80 81 81 3460 240 110 430 27.5 6182 G
T35 18.5 25 45.5 51.0 26.0 0.79 0.82 83 82 3450 240 110 430 27.5 6182 F
T35 22 30 53.5 59.5 30.0 0.79 0.81 84 84 3470 295 196 570 27.5 6182 H
T35 26 35 61.5 69.5 35.5 0.80 0.82 85 84 3470 250 210 585 27.5 6182 J
T35 30 40 67.0 75.5 41.5 0.81 0.83 84 84 3450 238 156 495 27.5 6182 G
T30 37 50 88.5 99.0 51.0 0.80 0.82 84 84 3460 310 202 575 27.5 6182 H
T50 5.5 7.5 15.8 17.6 8.80 0.78 0.80 72 72 3440 180 70 330 27.5 6182 E
T50 7.5 10 20.8 23.2 11.6 0.77 0.80 75 75 3450 190 80 340 27.5 6182 E
T50 9.2 12 24.4 27.5 14.0 0.80 0.81 76 76 3430 180 80 340 27.5 6182 E
T50 11 15 30.0 33.0 16.6 0.78 0.80 77 77 3450 200 90 370 27.5 6182 F
T50 13 18 34.5 38.5 19.2 0.78 0.81 78 78 3450 210 90 380 27.5 6182 F
T50 15 20 38.5 43.0 21.8 0.79 0.81 80 80 3460 230 110 420 27.5 6182 G
T50 18.5 25 46.0 51.5 26.5 0.81 0.82 81 80 3440 220 100 420 27.5 6182 F
T50 22 30 53.5 60.0 30.5 0.80 0.82 83 83 3470 280 184 545 27.5 6182 H
T50 26 35 62.0 70.0 36.0 0.81 0.83 83 83 3460 238 194 555 27.5 6182 H
T50 30 40 70.0 80.0 41.5 0.82 0.83 84 83 3450 232 154 490 27.5 6182 G
T50 37 50 88.5 99.5 51.5 0.80 0.83 84 83 3460 300 194 560 27.5 6182 H

20
MMS6
7

7. Wiring diagram

Wiring diagram
Wiring diagram
The motors are available for both direct-on-line and
star-delta starting.
Motors wound for star-delta starting can also be
connected for direct-on-line starting.
Direct-on-line starting

PE L1 L2 L3

PE U V W
TM03 2099 3705

M
3
Fig. 10 Motors wound for direct-on-line starting

Star-delta starting

PE L1 L2 L3

W2 U2 V2
TM03 2100 3705

PE U1 V1 W1

M
3

Fig. 11 Motors wound for star-delta starting


If star-delta starting is not required, but direct-on-line
starting is, the motor should be connected as shown in
fig. 12.

PE L1 L2 L3

W2 U2 V2
TM03 2101 3511

PEU1 V1 W1

M
3

Fig. 12 Motors wound for start-delta starting with


direct-on-line starting

21
8 MMS6

8. Accessories
Accessories

CUE frequency converter


The Grundfos CUE is a series of external frequency
converters designed for speed control of a wide range
of Grundfos pumps.
When a CUE is installed, the motor requires no further
motor protection.
The CUE offers quick and easy set-up and
commissioning compared to a standard frequency
converter because of the start-up guide. Simply enter
application-specific variables such as motor data,
pump family, control mode (for example constant
pressure), sensor type and setpoint, and the CUE will
automatically set all necessary parameters.
The CUE enables gentle pumping and thus protects
the water reservoir and the rest of the distribution
system, as water hammer can be avoided by adjusting
ramp times up and down.
Overview of the CUE range

Power [kW]
Supply voltage
[V] 0.55 0.75 1.1 7.5 11 45 250

GrA4404
3 x 525-690
3 x 525-600
3 x 380-500
3 x 200-240 Fig. 13 CUE frequency converters
1 x 200-240 Functions
The CUE is available in two enclosure classes: The CUE has a wide range of pump-specific functions,
• IP20/21 such as
• IP54/55. • constant pressure
RFI filters • constant level
• constant flow rate
To meet the EMC requirements, the CUE comes with
the following types of built-in radio frequency • constant temperature
interference filter (RFI). • constant curve.
Features
Typical shaft
Voltage
[V]
power (P2) RFI filter type Application • Start-up guide
[kW]
The CUE incorporates an innovative start-up guide
1 x 200-240 1.1 - 7.5 C1 for the general setting of the CUE including the
3 x 200-240 0.75 - 45 C1
Residential setting of the correct direction of rotation.
areas
The start-up guide is started the first time when the
0.55 - 90 C1
CUE is connected to the power supply.
3 x 380-500 Residential
110 - 250 C2 areas/ • Check of direction of rotation.
industry • Duty/standby operation.
3 x 525-600 0.75 - 7.5 C3 • Dry-running protection.
Industry
3 x 525-690 11 - 25 C3 • Low-flow stop function.

22
MMS6
8
Inputs and outputs Sensors

Accessories
The CUE incorporates various inputs and outputs: The following sensors can be used in connection with
• 1 RS-485 GENIbus connection the CUE. All sensors are with 4-20 mA output signal.
• 1 analog input, 0-10 V, 0/4-20 mA • Pressure sensors, up to 25 bar
– external setpoint • temperature sensors
• 1 analog input, 0/4-20 mA • differential-pressure sensors
– sensor input, feedback sensor • differential-temperature sensors
• 1 analog output, 0-20 mA • flowmeters
• 4 digital inputs • potentiometer box for external setpoint setting.
– start/stop and three programmable inputs Gateways
• 2 signal relays (C/NO/NC) The CUE has a standard RS-485 GENIbus interface.
– programmable. Gateways to convert to other bus standards are
available as accessories.
Accessories for the CUE
The Grundfos CIU family (CIU = Communication
Grundfos offers various accessories for the CUE.
Interface Units) can convert from GENIbus to the most
MCB 114 sensor input module common fieldbuses in the world:
The MCB 114 offers additional analog inputs for the • CIU 100 converts from GENIbus to LonWorks
CUE: • CIU 150 converts from GENIbus to Profibus DP
• 1 analog input, 0/4-20 mA • CIU 200 converts from GENIbus to Modbus RTU
• 2 inputs for Pt100 and Pt1000 temperature sensors. • CIU 250 is a GSM modem which can send SMS
Output filters messages in case of alarms, etc.
Output filters are used primarily to protect the motor Control MPC
against overvoltage and increased operating The Control MPC is a multi-pump control system for
temperature. However, output filters can also be used the control of parallel-connected CUE pump solutions.
to reduce acoustic noise from the motor.
Use of output filters
Grundfos offers two types of output filter as
accessories for the CUE: The table below shows in which cases an output filter
is required and which type to use.
• dU/dt filters
The selection depends on these factors:
• sine-wave filters.
• pump type
Floor-mounting option • motor cable length
The CUE is as standard installed on the wall. • the required reduction of acoustic noise from the
The enclosures D1 and D2 can also be installed on the motor.
floor on a pedestal designed for that purpose.
For information about enclosures, see the Typical shaft dU/dt filter
Sine-wave
product-specific documentation for the CUE. Pump type filter
power (P2) [m]
[m]
IP21/NEMA1 option Up to 7.5 kW - 0-300
SP with 380 V motor
An IP20 enclosure can be upgraded to IP21/NEMA1 by and up 11 kW and up 0-150 150-300
using the IP21/NEMA1 option. The power terminals
(mains and motor) will be covered. The lengths stated apply to the motor cable.

23
8 MMS6

Cables used in CUE installations The CUE is the right choice of frequency converter in
Accessories

Note: When the CUE is installed in connection with SP installations as it meets all basic issues. The CUE
SP pumps, we distinguish between two types of has a pre-installed start-up guide which takes the
installation: installer through all the necessary settings.
• installation in EMC-insensitive sites. See fig. 14. The table below shows the issues to be considered
when using frequency converters in SP installations.
• installation in EMC-sensitive sites. See fig. 15.
The two types of installation are different when it
Issues to be considered Explanation
comes to the use of screened cable.
Note: Drop cables are always unscreened. The journal bearings must be
Ramp (up and down):
lubricated in order to limit wear
Maximum 3 seconds.
and overheating of windings.
CUE Filter Overheating of the motor => low
Use temperature monitoring by
insulation resistance => sensitive
Pt sensor.
to voltage peaks.
Reduce peak voltages Never exceed peak voltages of
Mains cable, Screened Drop cable, (max. 800 V peaks). 850 V at motor leads.
unscreened cable
cable unscreened For MS and MMS, we recommend
to use motors with 10 % extra in
Grundfos CUE with output filter is
given duty point.
a safe solution.
For MMS, always use motors

TM04 4296 1109


(PE2 - PA wound).
Cables act as an amplifier =>
Remember output filter.
measure peaks at the motor.
Time between switches is an
expression of losses, so in the
Rise time (dU/dt) shall be limited
future, we might have to exceed
Fig. 14 Example of installation in EMC-insensitive sites to a maximum of 1000 V/μs.
the limit of 1000 V/μs.
Determined by the equipment in
The solution is not higher
the CUE.
insulation of the motor, but filter in
the output from the CUE.
CUE Filter
Min. 30 Hz.
Too low speed => no lubrication
Use a 60 Hz motor for larger
of journal bearings.
range.
Size the CUE in respect of the
Mains cable, Screened Screened Can end up with a too small CUE.
current, not the power output.
unscreened cable
cable cable
Size cooling provision for stator
Min. flow [m/s] along the stator
tube at duty point with lowest flow
housing must be considered.
rate.
Connection box
TM04 4295 1109

Ensure that the pump is used Focus on discharge pressure and


within the range of the pump sufficient NPSH, as vibrations will
curve. "kill" the motor.

Fig. 15 Example of installation in EMC-sensitive sites


Screened cables are required in those parts of the
installation where the surroundings must be protected
against EMC.

24
MMS6
8
MP 204 The MP 204 - many monitoring options

Accessories
The MP 204 monitors the following parameters:
The MP 204 is an electronic motor protector, designed
for the protection of an asynchronous motor or a pump. • insulation resistance before start-up
The motor protector consists of these parts: • temperature (Tempcon, Pt sensor and PTC/thermal
switch)
• a cabinet incorporating transformers and electronics
• overload/underload
• a control panel with operating buttons and display
for reading of data. • overvoltage/undervoltage
The MP 204 operates with two sets of limits: • phase sequence
• a set of warning limits • phase failure
• a set of trip limits. • power factor
If one or more of the warning limits are exceeded, the • power consumption
motor continues to run, but the warnings will appear in • harmonic distortion
the MP 204 display. • operating hours and number of starts.
Some values only have a warning limit.
The warning can also be read out by means of the
Grundfos R100 remote control.
If one of the trip limits is exceeded, the trip relay will
stop the motor. At the same time, the signal relay is
operating to indicate that the limit has been exceeded.
Applications

TM03 1471 2205


The MP 204 can be used as a stand-alone motor
protector.
The MP 204 can be monitored via a Grundfos
GENIbus.
The power supply to the MP 204 is in parallel with the Fig. 16 MP 204
supply to the motor. Motor currents up to 120 A are
Five sizes of single-turn transformers, 120 to 999 A.
passed directly through the MP 204. The MP 204
Note: Monitoring of motor temperature is not possible
protects the motor primarily by measuring the motor
when single-turn transformers are used.
current by means of a true RMS measurement.
It disconnects the contactor if, for example, the current
exceeds the preset value.
Secondarily, the pump is protected via temperature
measuring by a Tempcon sensor, a Pt100/Pt1000
sensor and a PTC sensor/thermal switch.

TM03 2033 3505


The MP 204 is designed for single- and three-phase
motors. In single-phase motors, the starting and run
capacitors are also measured. Cos φ is measured in
both single- and three-phase systems.
Fig. 17 Single-turn transformers
Benefits
Product numbers
The MP 204 offers these benefits:
• suitable for both single- and three-phase motors Product Product number
• dry-running protection MP 204 96079927
• overload protection R100 96615297
• very high accuracy Single-turn transformers
• made for submersible pumps. Current transformer ratio: 200:5, Imax. = 120 A 96095274
Current transformer ratio: 300:5, Imax. = 300 A 96095275
Current transformer ratio: 500:5, Imax. = 500 A 96095276
Current transformer ratio: 750:5, Imax. = 750 A 96095277
Current transformer ratio: 1000:5, Imax. = 1000 A 96095278

25
8 MMS6

Technical data, MP 204


Accessories

Enclosure class IP20


Ambient temperature -20 °C to +60 °C
Relative air humidity 99 %
Voltage range 100 to 480 VAC
Current range 3 to 999 A
Frequency 50 to 60 Hz
IEC trip class 1-45
Special Grundfos trip class 0.1 to 30 s
Voltage variation - 25 %/+ 15 % of rated voltage
Standards and approval EN 60947, EN 60335, UL/CSA 508
Marking CE, cUL, C-tick
Consumption Max. 5 W
Plastic type Black PC/ABS

Measuring range Accuracy Resolution


Current without external current transformers 3 - 120 A ±1% 0.1 A
Current with external current transformers 120 - 999 A ±1% 1A
Phase-to-phase voltage 80 - 610 VAC ±1% 1V
Frequency 47 - 63 Hz ±1% 0.5 Hz
Power 0 - 1 MW ±2% 1W
Power factor 0 - 0.99 ±2% 0.01
Energy consumption 0 - 4 x109 kWh ±5% 1 kWh

Technical data, IO 112

IO 112 Description Product number


The IO 112 is a measuring module and a 1-channel protection unit for use in
connection with the MP 204 motor protector. The module can be used for protection of
the pump against other factors than the electrical conditions, for instance dry running.
It can also be used as a stand-alone protection module.

The IO 112 has three inputs for measured values, one potentiometer for setting of
limits and indicator lights indicating the following:
• measured value of the input
• value of the limit set
96651601
• alarm source
• pump status.

Electrical data
• Supply voltage: 24 VAC - 10 %/+ 10 %, 50/60 Hz, or 24 VDC - 10 %/+ 10 %.
• Supply current: Min. 2.4 A, max. 8 A.
• Power consumption: Max. 5 W.
• Ambient temperature: -25 °C to +65 °C.
• Enclosure class: IP20.

Technical data, Control MP 204

Control MP 204 Description Product number


The Control MP 204 control cabinets are supplied with all necessary components.
Three types of control cabinets are available, depending on functions and starting
method.
The control cabinets are designed for installation in a control cabinet for outdoor use.
The Control MP 204 control cabinets have a built-in main switch and a thermal
magnetic circuit breaker.

Functions:
Digital input
• Float switch or pressure relay (if no IO 112 is used).
Analog input
• Too high motor temperature (Tempcon)
Consult WebCAPS on
• thermistor/PTC, pump
www.grundfos.com for
• pressure sensor, 4-20 mA (with IO 112).
product selection.
Relay output
• Pump alarm.
Communication
• Grundfos Remote Management.
• GSM/GPRS
(IO 112 not supported)
• Modbus RTU wired
(IO 112 not supported)
• Profibus DP
(IO 112 not supported).
Protection
• Protects the pump against short-circuit.

26
MMS6
8
G100 gateway for communication

Accessories
with Grundfos products
The G100 offers a wide selection of options for
integration of Grundfos products provided with
GENIbus interface into main control and monitoring
systems.
The G100 enables a pump installation to meet future
demands for optimum pump operation in terms of
reliability, operating costs, centralisation and
automation.

GR5940
Fig. 18 G100

Central management system

Profibus-DP
Radio Direct
Modem PLC
SMS

Radio

Main network POWER


POWER MNC
POWER GENI
GENI TxD
GENI RxD
DCD
RTS
TxD1
RxD1
TxD2
FAULT RxD2

Genibus DI Service
RS-232
4 digital inputs Service port for PC
Port 1 Port 2

Main
Network
Connection

Heating
GENIbus

MAGNA UPE TPE UPS

Water treatment Industry

Hydro
Multi-E MPC MGE E-pump MP 204 IO 351
MP 204 CU 300 DME E-pump IO 351

Pump Sensors
Pump SQE Sensors

Water supply Wastewater

Hydro MP 204 IO 351


MP 204 IO 351 CU 300 Multi-E
MPC
TM03 3743 0906

Pump Sensors SQE Pump Sensors

Fig. 19 Central management system

27
8 MMS6

Product description
Accessories

The G100 gateway enables communication of POWER DCD

operating data, such as measured values, setpoints,


POWER MNC RTS

POWER GENI TxD1

GENI TxD RxD1

GENI RxD TxD2

FAULT RxD2

etc., between Grundfos products with GENIbus


interface and a main network for control and

227 mm
Genibus DI Service

monitoring.
Port 1 Port 2

Figure 19 shows that the G100 is suitable for use in Main

Network

Connection

applications such as water supply, water treatment,

TM01 0621 0398


wastewater, building automation and industry.
Common to the above applications is that downtime is
usually costly, and extra investments are therefore
73 mm 165 mm
often made to achieve maximum reliability by
monitoring selected operating variables. Fig. 20 G100 dimensions
The day-to-day operation, such as starting and
stopping of pumps, changing of setpoints, etc., can Technical data
also be effected from the main system by Overview of protocols
communication with the G100. In addition, the G100
can be set up to send event-controlled status Main system Software protocol
indications such as alarms via the SMS to mobile Profibus-DP DP
phones, and to make automatic alarm call-backs to a Radio Satt Control COMLI/Modbus
central management system. Modem Satt Control COMLI/Modbus
Data logging PLC Satt Control COMLI/Modbus
GSM mobile phone SMS, UCP
Besides the possibility of data communication, the
G100 offers logging of up to 350,000 time-stamped Other possible connections
data. Subsequently, the logged data can be
transmitted to the main system or a PC for further GENIbus RS-485 Connection of up to 32 units
analysis in a spreadsheet or similar program. For direct connection to a PC or via
Service port RS-232
radio modem
For the data logging, the "PC Tool G100 Data Log"
Digital inputs 4
software tool is used. The tool is part of the PC Tool
Power supply 1 x 110-240 V, 50/60 Hz
G100 package which is supplied with the G100.
Ambient temperature During operation: -20 °C to +60 °C
Other features Enclosure class IP20
• Four digital inputs Weight 1.8 kg
• stop of all pumps in case of failing communication
Accessories
with the management system (optional)
• access code for modem communication (optional) • PC Tool G100 package (supplied with the product)
• "G100 Support Files" CD-ROM (supplied with the
• alarm log.
product).
Installation
Product numbers
The G100 is installed by the system integrator.
The G100 is connected to the GENIbus as well as to Product Product number
the main network. Subsequently, all units on the
G100 with Profibus-DP expansion board* 96411135
GENIbus can be controlled from a central
G100 with Radio/Modem/PLC-expansion board* 96411136
management system on the main network.
G100 Basic Version* 96411137
The "G100 Support Files" CD-ROM supplied with the PC Tool G100 package 96415783
G100 contains examples of programs to be used when * CD-ROM with G100 Support Files included.
the G100 is connected to the various main network
systems. The CD-ROM also includes a description of
the data points available in Grundfos products with
GENIbus interface.
The "PC Tool G100" software tool can be used for the
G100 installation and use.

28
MMS6
8
Cable termination kit, type KM

Accessories
Version
Product
Product Description Number of number
Motor cable [mm2] leads
For watertight shrink-joining of motor 1.5 - 6.0 3
Flat cable 116251
cable and submersible drop cable: 1.5 - 4.0 4
• cables of equal size. 6 - 10 4
• cables of different sizes. Flat cable 116252
10 - 16 3
• a cable lead and a single lead.
The joint is ready for use after a few 3
Flat cable 16 - 25 116255
minutes and requires no long 4
hardening time as do resin joints.
The joint cannot be separated.

TM04 4977 3511

For watertight shrink-joining of motor Single lead 10 - 70 1 96828296


cable and submersible drop cable: Single lead 35 - 120 1 116256
• cables of equal size.
• cables of different sizes. Screw-shrinking 70 - 240 4 96637279
• a cable lead and a single lead.
The joint is ready for use after a few
minutes and requires no long
hardening time as do resin joints.
The joint cannot be separated.
TM04 4978 2309

For watertight joining of motor cable 6 - 35 96636867


and submersible drop cable. Screw-shrinking 19 - 95 4 96636868
By means of shrink-screw-glue
casting. 35 - 185 96637278
TM04 4979 2309

Reducing from 3 or 4 to one as from 10 - 50 3 96637318


drop cable to single leads. 10 - 50 4 96637330
Reducer-shrinking
16 - 70 3 96637331
16 - 70 4 96637332
3 single leads 1.5 - 6.0 3 116253
3 single leads 10 - 25 3 116254
4 single leads 1.5 - 4.0 4 116257
4 single leads 6 - 16 4 116258
TM04 4980 2309

Mastik for flat cables


Product
Description
number
Mastik for flat cables with separate earth, 48 pcs. 96788662

29
8 MMS6

Cable termination kit, types M0 to M6


Accessories

Product Description Version


Product
Diameter of Outer cable
Type cable joint diameter number
[mm] [mm]
M0 ∅40 ∅6 - ∅15 ID8903
For watertight joining of motor M1 ∅46 ∅9 - ∅23 ID8904
cable and submersible drop cable. M2 ∅52 ∅17 - ∅31 ID8905
The joint is encapsulated by the
glue which is part of the kit. M3 ∅77 ∅26 - ∅44 ID8906

TM04 4981 2309


M4 ∅97 ∅29 - ∅55 91070700

Cross-section of
leads Number of Product
connectors number
[mm2]
Accessories for cable kits M0 to 6-25 96626021
M6. 16-95 96626022
Screw connectors only. 4
35-185 96626023
GrA8251

70-240 96626028

Submersible drop cable


Product Description

Number of
Outer cable
leads and
diameter Weight Product
nominal
min./max. [kg/m] number
cross-section
[mm]
[mm2]
1 x 25 12.5 / 16.5 0.410 ID4072
1 x 35 14.0 / 18.5 0.560 ID4073
Suitable for these applications: 1 x 50 16.5 / 21.0 0.740 ID4074
• continuous application in groundwater and
potable water (approved for potable-water 1 x 70 18.5 / 23.5 1.000 ID4075
applications) 1 x 95 21.0 / 26.5 1.300 ID4076
• connection of electrical equipment, such as 1 x 120 23.5 / 28.5 1.650 ID4077
TM00 7882 2296

submersible motors
• installation depths up to 600 metres and 1 x 150 26.0 / 31.5 2.000 ID4078
average loads. 1 x 185 27.5 / 34.5 2.500 ID4079
Insulation and sheath of special EPR-based
3 x 25 26.5 / 34.0 1.450 ID4062
elastomer materials adapted to applications in
water. 4G1.5 10.5 / 13.5 0.190 ID4063
Maximum permissible water temperature: 70 °C. 4G2.5 12.5 / 15.5 0.280 ID4064
Maximum permissible lead service temperature:
90 °C. 4G4.0 14.5 / 18.0 0.390 ID4065
Further cable sizes are available on request. 4G6.0 16.5 / 22.0 0.520 ID4066
4G10 22.5 / 24.5 0.950 ID4067
4G16 26.5 / 28.5 1.400 ID4068
4G25 32.0 / 34.0 1.950 ID4069
4G35 33.0 / 42.5 2.700 96432949
4G50 38.0 / 48.5 3.600 96432950
4G70 43.0 / 54.5 4.900 96432951

Cable clips Description Product number

For fastening of cable and straining wire to the riser pipe.


The clips should be fitted every 3 metres.
TM00 1369 5092

One set for approx. 45 m riser pipe. 115016


• 16 cable buttons.
• 7.5 m rubber band.

30
MMS6
8
Zinc anodes Flow sleeves

Accessories
Application Grundfos offers a complete range of stainless-steel
flow sleeves for both vertical and horizontal operation.
Cathodic protection by means of zinc can be used for
We recommend flow sleeves for all applications in
corrosion protection of SP pumps in
which motor cooling is insufficient. The result is a
chloride-containing liquids, such as brackish water and
general extension of motor life.
seawater.
Flow sleeves are to be used in these cases:
Sacrificial anodes are placed on the outside of the
pump and motor as protection against corrosion. • If the submersible pump is exposed to high thermal
See fig. 21. load like current unbalance, dry running, overload,
high ambient temperature or bad cooling conditions.
• If aggressive liquids are pumped, since corrosion is
doubled for every 10 °C the temperature rises.
• If sedimentation or deposits occur around and/or on
the motor.
Note: More information about flow sleeves is available
on request.

TM05 0537 1211

Fig. 21 Submersible motor fitted with anode strings

The number of anodes required depends on the pump


and motor in question.
Please contact Grundfos for further details.

TM01 0751 2197 - TM01 0750 2197


Fig. 22 Flow sleeves

31
8 MMS6

Pt100 sensor Technical data


Accessories

The Pt100 sensor offers these features: Relay type


• continuous monitoring of the motor temperature PR 5714
• protection against too high motor temperature. Enclosure class IP65 (mounted in a control panel)
Protecting the motor against too high motor Ambient temperature -20 °C to +60 °C
temperature is the simplest and cheapest way of Relative humidity 95 % (condensating)
ensuring long motor life. The Pt100 ensures that the 1 x 24-230 VAC - 10 %/+ 10 %, 50-60 Hz
Voltage variation
operating conditions are not exceeded and indicates 24-250 VDC - 20 %/+ 20 %
when it is time to service the motor. Approvals UL, DNV

Monitoring and protection by means of a Pt100 require Marking CE

the following parts:


• Pt100 sensor
• PR 5714 relay
• cable.
The PR 5714 relay is fitted with a Pt100 sensor.
The following temperature limits are preset on delivery:
• 60 °C warning limit
Recommended setting: T-code +5 °C.
• 75 °C stop limit
Recommended setting: T-code +15 °C.

Product number
Cable length
Pt100 sensor with/without PR 5714 relay and cable PR 5714 MMS6
[m] MMS 10000
MS6 MMS 6000
MMS 12000
MMS 8000
20 Yes 96408953 96494596 96437287
40 Yes 96408681 96494597 96437288
60 Yes 96408954 96494598 96437289
80 Yes 96408955 96494599 96437290
100 Yes 96408956 96494610 96437291
20 No 96658626 96658629 96658633
40 No 96658627 96658630 96658634
60 No 96658628 96658631 96658635
GrA3187

80 No 96658637 96658632 96658636


100 No 96658638 96658639 96658640

PR 5714 relay Voltage Product number

24-230 VAC, 50/60 Hz / 24-250 VDC 96913234


GrA3186

Cable length
Pt100 sensor, including cable Product number
[m]

20 96913237

40 96913253

60 96913256

80 96913260
GrA3190

100 96913263

32
MMS6
8

Accessories
Extension kit for sensor cable for Pt100 Description Product number

Extension kit for Pt100 sensor cable.

TM00 7885 2296


For watertight shrink-joining of the sensor cable. 96571480
Extra sensor cable must be ordered separately.

Sensor cable Description Product number

TM00 7882 2296


Drop cable for extension.
Mention length when ordering. RM5271
Maximum recommended length: 350 m.

33
8 MMS6

Pt1000 sensor The following temperature limits are preset on delivery:


Accessories

• 50 °C warning limit
The Pt1000 sensor offers these features:
Recommended setting: T-code +5 °C.
• continuous monitoring of the motor temperature
• 60 °C stop limit
• protection against too high motor temperature. Recommended setting: T-code +15 °C.
Protecting the motor against too high motor The Pt1000 sensor works within the temperature range
temperature is the simplest and cheapest way of of -60 °C to +120 °C.
ensuring long motor life. The Pt1000 ensures that the
operating conditions are not exceeded and indicates Technical data
when it is time to service the motor.
CU 220
Monitoring and protection by means of a Pt1000
Enclosure class IP65 (mounted in a control panel)
require the following parts:
Ambient temperature 0 °C to +55 °C
• Pt1000 sensor
Relative humidity 20-80 % (condensating)
• CU 220 control unit Voltage variation 1 x 230 V - 15 %/+ 10 %, 50 Hz
• cable Approvals UR
• staybolt kit for Pt1000. Marking CE

The CU 220 control unit is fitted with a Pt1000 sensor.

Product number
Cable
Pt1000 sensor with CU 220 control unit, cable and
length CU 220 MMS6
staybolt or insertion probe MMS 10000
[m] MS6 MMS 6000
MMS 12000
MMS 8000
20 Yes 96803207 96803233 96803238
TM04 3561 4508 - TM04 3563 4508
TM04 3562 4508 - TM04 3560 4508

40 Yes 96803241 96803252 96803253


60 Yes 96803254 96803255 96803257
80 Yes 96803258 96803292 96803294
100 Yes 96803301 96803312 96803313

CU 220 control unit Voltage Product number


TM04 3561 4508

1 x 230 V - 15 %/+ 10 %, 50 Hz 96797484

Cable length
Pt1000 sensor, including cable Product number
[m]

20 96804042

40 96804044
TM04 3563 4508

60 96804064

80 96804065

100 96804067

34
MMS6
8

Accessories
Extension kit for sensor cable for Pt1000 Description Product number

Extension kit for Pt1000 sensor cable.


For watertight shrink-joining of the sensor cable. 96571480

TM00 7885 2296


Extra sensor cable must be ordered separately.

Sensor cable Description Product number

TM00 7882 2296


Drop cable for extension.
Mention length when ordering. RM5271
Maximum recommended length: 350 m.

35
9 MMS6

9. Cable sizing
Cable sizing

Drop cables Example


Grundfos offers submersible drop cables for all types Motor size: 30 kW, MMS6
of application, i.e. 3-core cables, 4-core cables and Rated current: 68.2 A
single leads. Rated voltage: 3 x 400 V, 50 Hz
The selection of submersible drop cable depends on Starting method: Direct-on-line
the application and type of installation. Power factor: cos φ = 0.81
Standard version: Maximum liquid temperature +60 °C. Voltage drop: 3%
Cross-section: 25 mm2
Tables indicating cable dimensions in borehole
sin φ: 0.59
The tables indicate the maximum length of drop cables
in metres from motor-protective circuit breaker to
400  3
pump for direct-on-line starting, and at different cable L = ------------------------------------------------------------------------------------------------------------------------------------------------------
0.025 –3
dimensions. 68.2  1.73  100  0.81  --------------- + 0.59  0.078  10 

 25 
The lengths of the cables are calculated by means of
the maximum current for cables according to IEC 364 L = 119 m.
and HD 384.
If, for example, the operating current is 10 % lower
than the rated current, the cable may be 10 % longer
than indicated in the table.
The calculation of the cable length is based on a
maximum voltage drop of 3 % of the rated voltage and
a water temperature of maximum +30 °C.
To minimise operating losses, the cable cross-section
may be increased compared to what is indicated in the
table. This is economical only in these cases:
• The borehole provides the necessary space.
• The operating time of the pump is long.
• The operating voltage is lower than the rated
voltage.
The table values are calculated on the basis of the
following formula:
Maximum cable length of a three-phase
submersible pump

U  U
L = --------------------------------------------------------------------------------------------------------  m 

I  1.73  100   cos   --- + sin   X 
q L

Legend
U = Rated voltage [V]
ΔU = Voltage drop [%]
I = Rated current of the motor [A]
q = Cross-section of submersible drop cable
[mm2]
XL = Inductive resistance: 0.078 x 10-3 [Ω/m]
cos φ = Power factor
sin φ = 1 – cos2 
ρ = Specific resistance: 0.025 [Ωmm2/m]

36
MMS6
9
Cable sizing Example

Cable sizing
Motor size: 30 kW, MMS6
Calculation of cable cross-section
Rated current: I1/1 = 68.2 A
Legend Rated voltage: 3 x 400 V, 50 Hz
U = Rated voltage [V] Starting method: Direct-on-line
Required cable length: 200 m
ΔU = Voltage drop [%]
Water temperature: 25 °C
I = Rated current of the motor [A] cos φ: 0.81
q = Cross-section [mm2] Cable selection:
Choice A: 3 x 35 mm2
XL = Inductive resistance 0.078 x 10-3 [Ω/m] Choice B: 3 x 50 mm2
cos φ = Power factor Calculation of power loss
sin φ = 1– cos2  Choice A
L = Cable length [m] 2
LI
Δp = Power loss [W] p A = 3
---------------------------
q
r = 1/c
3  200  0.02  68.2 2-
Cable material p A = ----------------------------------------------------
35
Copper: c = 40 m/W x mm2
Aluminium: c = 35 m/W x mm2
p A = 1594 W
For calculation of the cross-section of the submersible
drop cable, use the following formulas: Choice B
Direct-on-line
3  200  0.02   68.2 
2
p B = ------------------------------------------------------------
I  1.73  100  L    cos  50
q = ------------------------------------------------------------------------------------------------
-
U  U –  I  1.73  100  L  X  sin  
L ΔpB = 1116 W
Savings
68.2  1.73  100  200  1/52  0.81 Operating hours/year: h = 4000.
q = ------------------------------------------------------------------------------------------------------------------------
-
400  3 –  68.2  1.73  100  200  0.078  0.59  Annual saving (A):
q = 35 mm2
A =  p – p   h =  1594 W – 1116 W   4000 = 1912000 Wh
Star-delta A B
A = 1912 kWh
I  100  L    cos  By choosing the cable size 3 x 50 mm2 instead of
q = --------------------------------------------------------------------------------
U  U –  I  100  L  X  sin   3 x 35 mm2, an annual saving of 1912 kWh is
L
achieved.
The values of the rated current (I) and the power factor
(cos φ) can be found in the tables on pages 14 to 20. Operating time: 10 years
Saving after 10 years (A10):
Calculation of power loss
For calculation of the power loss in the submersible A = A  10 = 1912  10 = 19120 kWh
10
drop cable, use the following formula:
The saving must be calculated in the local currency.
2
3LI
p = ---------------------------
q

37
10 MMS6

10. Order data


Order data

Legend
- = Not in the standard program, i.e. FPV variant.
❍ = Not produceable.
● = We recommend to use of PE2/PA windings.

3 x 200 V, 50 Hz, and 3 x 200-220 V, 60 Hz, SF 1.0, Japan


Product number

PE2/PA windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 - - - - - - - - - -
7.5 10 - - - - - - - - - -
9.2 12 - - - - - - - - - -
11 15 - - - - - - - - - -
MMS6

13 17 - - - - - - - - - -
15 20 - - - - - - - - - -
18.5 25 - - - - - - - - - -
22 30 - - - - - - - - - -
26 35 - - - - - 96879531 - - - 96879533
30 40 - - - - - 96879532 - - - 96879534
37 50 ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍

3 x 220-230 V, 50 Hz
Product number

PVC windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 96881044 - 96881051 - - - - - ● ●
7.5 10 96881045 - 96881052 - - - - - ● ●
9.2 12 96881046 - 96881053 - - - - - ● ●
11 15 96881047 - 96881054 - - - - - ● ●
MMS6

13 17 96881048 - 96881055 - - - - - ● ●
15 20 96881049 - 96881056 - - - - - ● ●
18.5 25 96881050 - 96881057 - - - - - ● ●
22 30 96879499 - 96879503 - - - - - ● ●
26 35 96879500 - 96879504 - - - - - ● ●
30 40 96879501 - 96879505 - - - - - ● ●
37 50 ❍ 96879502 ❍ 96879506 ❍ - ❍ - ● ●

38
MMS6
10

Order data
Product number

PE2/PA windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 - - - - 96881058 - 96881065 - 96881072 -
7.5 10 - - - - 96881059 - 96881066 - 96881073 -
9.2 12 - - - - 96881060 - 96881067 - 96881074 -
11 15 - - - - 96881061 - 96881068 - 96881075 -
MMS6

13 17 - - - - 96881062 - 96881069 - 96881076 -


15 20 - - - - 96881063 - 96881070 - 96881077 -
18.5 25 - - - - 96881064 - 96881071 - 96881078 -
22 30 - - - - 96879507 - 96879511 - 96879515 -
26 35 - - - - 96879508 - 96879512 - 96879516 -
30 40 - - - - 96879509 - 96879513 - 96879517 -
37 50 ❍ - ❍ - ❍ 96879510 ❍ 96879514 ❍ 96879518

3 x 380-400-415 V, 50 Hz, and 3 x 460 V, 60 Hz


Product number

PVC windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 96880880 ❍ 96880891 ❍ 96880902 ❍ 96880913 ❍ ● ●
7.5 10 96880881 ❍ 96880892 ❍ 96880903 ❍ 96880914 ❍ ● ●
9.2 12 96880882 ❍ 96880893 ❍ 96880904 ❍ 96880915 ❍ ● ●
11 15 96880883 96880887 96880894 96880898 96880905 96880909 96880916 96880920 ● ●
MMS6

13 17 96880884 96880888 96880895 96880899 96880906 96880910 96880917 96880921 ● ●


15 20 96880885 96880889 96880896 96880900 96880907 96880911 96880918 96880922 ● ●
18.5 25 96880886 96880890 96880897 96880901 96880908 96880912 96880919 96880923 ● ●
22 30 96879377 96879381 96879385 96879389 96879393 96879397 96879401 96879405 ● ●
26 35 96879378 96879382 96879386 96879390 96879394 96879398 96879402 96879406 ● ●
30 40 96879379 96879383 96879387 96879391 96879395 96879399 96879403 96879407 ● ●
37 50 96879380 96879384 96879388 96879392 96879396 96879400 96879404 96879408 ● ●

Product number

PE2/PA windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 96880924 ❍ 96880934 ❍ 96880944 ❍ 96880954 ❍ 96880964 ❍
7.5 10 96880925 ❍ 96880935 ❍ 96880945 ❍ 96880955 ❍ 96880965 ❍
9.2 12 96880926 ❍ 96880936 ❍ 96880946 ❍ 96880956 ❍ 96880966 ❍
11 15 96880927 ❍ 96880937 ❍ 96880947 ❍ 96880957 ❍ 96880967 ❍
MMS6

13 17 96880928 96880931 96880938 96880941 96880948 96880951 96880958 96880961 96880968 96880971
15 20 96880929 96880932 96880939 96880942 96880949 96880952 96880959 96880962 96880969 96880972
18.5 25 96880930 96880933 96880940 96880943 96880950 96880953 96880960 96880963 96880970 96880973
22 30 96879409 96879413 96879417 96879421 96879425 96879429 96879433 96879437 96879441 96879445
26 35 96879410 96879414 96879418 96879422 96879426 96879430 96879434 96879438 96879442 96879446
30 40 96879411 96879415 96879419 96879423 96879427 96879431 96879435 96879439 96879443 96879447
37 50 96879412 96879416 96879420 96879424 96879428 96879432 96879436 96879440 96879444 96879448

39
10 MMS6

3 x 380-400-415 V, 50 Hz, and 3 x 460 V, 60 Hz (boxed up for sea freightage)


Order data

Product number

PE2/PA windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 - ❍ - ❍ - ❍ - ❍ - ❍
7.5 10 - ❍ - ❍ - ❍ - ❍ - ❍
9.2 12 - ❍ - ❍ - ❍ - ❍ - ❍
11 15 - ❍ - ❍ - ❍ - ❍ - ❍
MMS6

13 17 - - - - - - - - - -
15 20 - - - - - - - - - -
18.5 25 - - - - - - - - - -
22 30 - - - - - - - - - -
26 35 - - - - - - - - - -
30 40 - - - - 96879559 - 96879561 - 96879563 -
37 50 - - - - 96879560 - 96879562 - 96879564 -

3 x 400 V, 50 Hz, and 3 x 400-440 V, 60 Hz, SF 1.0, Japan


Product number

PE2/PA windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 - ❍ - ❍ - ❍ - ❍ - ❍
7.5 10 - ❍ - ❍ - ❍ - ❍ - ❍
9.2 12 - ❍ - ❍ - ❍ - ❍ - ❍
11 15 - ❍ - ❍ - ❍ - ❍ - ❍
MMS6

13 17 - - - - - - - - - -
15 20 - - - - - - - - - -
18.5 25 - - - - - - - - - -
22 30 - - - - - - - - - -
26 35 - - - - - 96879535 - - - 96879537
30 40 - - - - - 96879536 - - - 96879538
37 50 ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍

3 x 400-415 V, 50 Hz, Australia


Product number

PE2/PA windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 - ❍ - - - ❍ - ❍ - ❍
7.5 10 - ❍ - - - ❍ - ❍ - ❍
9.2 12 - ❍ - - - ❍ - ❍ - ❍
11 15 - ❍ - - - ❍ - ❍ - ❍
MMS6

13 17 - - - - - - - - - -
15 20 - - - - - - - - - -
18.5 25 - - - - - - - - - -
22 30 - - - - - - - - - -
26 35 - - - - - - - - - -
30 40 96879449 - 96879451 - 96879453 - 96879455 - 96879457 -
37 50 96879450 - 96879452 - 96879454 - 96879456 - 96879458 -

40
MMS6
10
3 x 460 V, 50 Hz

Order data
Product number

PVC windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ● ●
7.5 10 96881094 ❍ 96881100 ❍ - ❍ - ❍ ● ●
9.2 12 96881095 ❍ 96881101 ❍ - ❍ - ❍ ● ●
11 15 96881096 ❍ 96881102 ❍ - ❍ - ❍ ● ●
MMS6

13 17 96881097 ❍ 96881103 ❍ - ❍ - ❍ ● ●
15 20 96881098 - 96881104 - - - - - ● ●
18.5 25 96881099 - 96881105 - - - - - ● ●
22 30 96879539 - 96879543 - - - - - ● ●
26 35 96879540 - 96879544 - - - - - ● ●
30 40 96879541 - 96879545 - - - - - ● ●
37 50 96879542 - 96879546 - - - - - ● ●

Product number

PE2/PA windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
7.5 10 - ❍ - ❍ 96881106 ❍ 96881112 ❍ 96881118 ❍
9.2 12 - ❍ - ❍ 96881107 ❍ 96881113 ❍ 96881119 ❍
11 15 - ❍ - ❍ 96881108 ❍ 96881114 ❍ 96881120 ❍
MMS6

13 17 - ❍ - ❍ 96881109 ❍ 96881115 ❍ 96881121 ❍


15 20 - - - - 96881110 - 96881116 - 96881122 -
18.5 25 - - - - 96881111 - 96881117 - 96881123 -
22 30 - - - - 96879547 - 96879551 - 96879555 -
26 35 - - - - 96879548 - 96879552 - 96879556 -
30 40 - - - - 96879549 - 96879553 - 96879557 -
37 50 - - - - 96879550 - 96879554 - 96879558 -

3 x 500-525 V, 50 Hz, and 3 x 575 V, 60 Hz, SF 1.15


Product number

PE2/PA windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
7.5 10 ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
9.2 12 - ❍ - ❍ 96881079 ❍ 96881084 ❍ 96881089 ❍
11 15 - ❍ - ❍ 96881080 ❍ 96881085 ❍ 96881090 ❍
MMS6

13 17 - ❍ - ❍ 96881081 ❍ 96881086 ❍ 96881091 ❍


15 20 - ❍ - ❍ 96881082 ❍ 96881087 ❍ 96881092 ❍
18.5 25 - - - - 96881083 - 96881088 - 96881093 -
22 30 - - - - 96879519 - 96879523 - 96879527 -
26 35 - - - - 96879520 - 96879524 - 96879528 -
30 40 - - - - 96879521 - 96879525 - 96879529 -
37 50 - - - - 96879522 - 96879526 - 96879530 -

41
10 MMS6

3 x 220-230 V, 60 Hz, SF 1.15


Order data

Product number

PVC windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 96881009 - 96881016 - 96881197 - - - ● ●
7.5 10 96881010 - 96881017 - 96881198 - - - ● ●
9.2 12 96881011 - 96881018 - 96881199 - - - ● ●
11 15 96881012 - 96881019 - 96881200 - - - ● ●
MMS6

13 17 96881013 - 96881020 - 96881201 - - - ● ●


15 20 96881014 - 96881021 - 96881202 - - - ● ●
18.5 25 96881015 - 96881022 - 96881203 - - - ● ●
22 30 96879479 - 96879483 - 96881204 - - - ● ●
26 35 96879480 - 96879484 - 96881205 - - - ● ●
30 40 96879481 - 96879485 - 96881206 - - - ● ●
37 50 ❍ 96879482 ❍ 96879486 ❍ 96881207 ❍ - ● ●

Product number

PE2/PA windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 - - - - 96881023 - 96881030 - 96881037 -
7.5 10 - - - - 96881024 - 96881031 - 96881038 -
9.2 12 - - - - 96881025 - 96881032 - 96881039 -
11 15 - - - - 96881026 - 96881033 - 96881040 -
MMS6

13 17 - - - - 96881027 - 96881034 - 96881041 -


15 20 - - - - 96881028 - 96881035 - 96881042 -
18.5 25 - - - - 96881029 - 96881036 - 96881043 -
22 30 - - - - 96879487 - 96879491 - 96879495 -
26 35 - - - - 96879488 - 96879492 - 96879496 -
30 40 - - - - 96879489 - 96879493 - 96879497 -
37 50 ❍ - ❍ - ❍ 96879490 ❍ 96879494 ❍ 96879498

42
MMS6
10
3 x 380 V, 60 Hz, SF 1.15

Order data
Product number

PVC windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 96880974 ❍ 96880981 ❍ - ❍ - ❍ ● ●
7.5 10 96880975 ❍ 96880982 ❍ - ❍ - ❍ ● ●
9.2 12 96880976 ❍ 96880983 ❍ - ❍ - ❍ ● ●
11 15 96880977 - 96880984 - - - - - ● ●
MMS6

13 17 96880978 - 96880985 - - - - - ● ●
15 20 96880979 - 96880986 - - - - - ● ●
18.5 25 96880980 - 96880987 - - - - - ● ●
22 30 96879459 - 96879463 - - - - - ● ●
26 35 96879460 - 96879464 - - - - - ● ●
30 40 96879461 - 96879465 - - - - - ● ●
37 50 96879462 - 96879466 - - - - - ● ●

Product number

PE2/PA windings
Motor power
Ceramic/carbon SiC/SiC

EN-JL1040 DIN/EN 1.4401 EN-JL1040 DIN/EN 1.4401 DIN/EN 1.4539

[kW] [hp] DOL SD DOL SD DOL SD DOL SD DOL SD


5.5 7 - ❍ - ❍ 96880988 ❍ 96880995 ❍ 96881002 ❍
7.5 10 - ❍ - ❍ 96880989 ❍ 96880996 ❍ 96881003 ❍
9.2 12 - ❍ - ❍ 96880990 ❍ 96880997 ❍ 96881004 ❍
11 15 - - - - 96880991 - 96880998 - 96881005 -
MMS6

13 17 - - - - 96880992 - 96880999 - 96881006 -


15 20 - - - - 96880993 - 96881000 - 96881007 -
18.5 25 - - - - 96880994 - 96881001 - 96881008 -
22 30 - - - - 96879467 - 96879471 - 96879475 -
26 35 - - - - 96879468 - 96879472 - 96879476 -
30 40 - - - - 96879469 - 96879473 - 96879477 -
37 50 - - - - 96879470 - 96879474 - 96879478 -

43
11 MMS6

11. Further product documentation


Further product documentation

WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
220,000 Grundfos products in more than
30 languages.
Information in WebCAPS is divided into six sections:
• Catalogue
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.

Catalogue

Based on fields of application and pump types, this section


contains the following:
• technical data
• curves (QH, Eta, P1, P2, etc.) which can be adapted to the
density and viscosity of the pumped liquid and show the
number of pumps in operation
• product photos
• dimensional drawings
• wiring diagrams
• quotation texts, etc.

Literature

This section contains all the latest documents of a given pump,


such as
• data booklets
• installation and operating instructions
• service documentation, such as Service kit catalogue and
Service kit instructions
• quick guides
• product brochures.

Service

This section contains an easy-to-use interactive service


catalogue. Here you can find and identify service parts of both
existing and discontinued Grundfos pumps.
Furthermore, the section contains service videos showing you
how to replace service parts.

44
MMS6
11

Further product documentation


Sizing 0 1

This section is based on different fields of application and


installation examples and gives easy step-by-step instructions in
how to size a product:
• Select the most suitable and efficient pump for your
installation.
• Carry out advanced calculations based on energy,
consumption, payback periods, load profiles, life cycle costs,
etc.
• Analyse your selected pump via the built-in life cycle cost tool.
• Determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to selecting and comparing


replacement data of an installed pump in order to replace the
pump with a more efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare


Grundfos pumps with the one you have installed on your site.
When you have specified the installed pump, the guide will
suggest a number of Grundfos pumps which can improve both
comfort and efficiency.

CAD drawings

In this section, it is possible to download 2-dimensional (2D) and


3-dimensional (3D) CAD drawings of most Grundfos pumps.

These formats are available in WebCAPS:

2-dimensional drawings:
• .dxf, wireframe drawings
• .dwg, wireframe drawings.

3-dimensional drawings:
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed
information on more than 220,000 Grundfos products
in more than 30 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no internet
connection is available.
WinCAPS is available on CD-ROM and updated once
a year.

Fig. 23 WinCAPS CD-ROM

Subject to alterations.

45
46
47
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence

97824689 1111
GB
Repl. 97824689 1210
The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registrated trademarks
ECM: 1084616 owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark