You are on page 1of 7

Missing Trace

37,50,77,79

Missing PGW logs


1,2,9,42,43,44,45,47,48,49,50,53,54,55,57(if
Needed),58,60,61,63,65,67,76,77,78,79,81<->134,137,144<->164

VLR : 491720438173

Missing TC description
1-> 14,27,42,43,44,46,47,50,55,56,58,59,61->85,88,92,97->134,137,140->143,145-
>155,158,162->165

140 ->153,162 to 165, 88, 71-75

--------------------------------------------------------------------------

'TEST CASE NAME: TO09.0140-2G Combined Attach of a non VoLTE Nokia 3+2 UC Slave
Card being APD

Test Case Title: Attached to 2G of HPLMN using Slave APD activated subscriber

PRE-REQUISITES:

- we have to verify if the subscriber is provisioing with non VoLTE Nokia 3+2 UC
Slave Card
- UC 3+2 slave card should be APD device
- RSI should be "NN" state and EUINTERNET PDP context should not be selected
- Take fresh Subscriber Profile logs in PGW GUI

Display PGW logs comment : ./display.sh 262090461004024

EXECUTION STEPS:

- We have to attach 2G Network of HPLMN in Handset


- assign one authentication key along with subscriber
- Check RSI is NN and PDP context "EUINTERNET" should not be activate

EXPECTED RESULTS:

NT HLR -> HPLMN VLR:


MAP ISD (IMSI; Subscription Data: new BS + new MSISDN)
HPLMN VLR -> NT HLR:
MAP ISD (Result: Success)

- Take Subscriber post profile log in PGW CLI along with IMSI

WIRESHARK FILTER FOR RESULT EVALUATION:

-(esp contains "262090461004022"||sip contains "262090461004022" || diameter


contains "262090461004022"||e164.msisdn contains "262090461004022"||e212.imsi
contains "262090461004022"||

esp contains "262090461004023"||sip contains "262090461004023" || diameter contains


"262090461004023"||e164.msisdn contains "262090461004023"||e212.imsi contains
"262090461004023"||

esp contains "262090461004024"||sip contains "262090461004024" || diameter contains


"262090461004024"||e164.msisdn contains "262090461004024"||e212.imsi contains
"262090461004024"||

http || gtpv2.message_type == 25 || gtpv2.message_type == 26 || gtpv2.message_type


== 27)

---------------------------------------------------------------------------------

TEST CASE NAME: TO09.145- non VoLTE Nokia UC 3+2 Group - Call Forwarding change via
SCI - UC Slave Membe

Test Case Title: Change SS CF via Slave UC 3+2 group will refect all group
subscribers

PRE-REQUISITES:

- we have to choose Non Volte UC 3+2 group slave card number


- we have to check before CFB should be activated in UC all group number

- Take fresh Subscriber Profile logs in PGW GUI

Display PGW logs comment : ./display.sh 262090461004024

EXECUTION STEPS:

- We have to change CFB number in one of UC slave card in PGW GUI


- we get notification changes from all UC 3+2 group cards
-

EXPECTED RESULTS:

- NT HLR FE updates all 3 UC members of the non VoLTE Nokia UC 3+2 group

- NT HLR FE sends per member an ISD about the CF change

- TAS reads the MMTEL data via Restore Data message from Master.

- Take Subscriber post profile log in PGW CLI along with IMSI

WIRESHARK FILTER FOR RESULT EVALUATION:

-(esp contains "262090461004022"||sip contains "262090461004022" || diameter


contains "262090461004022"||e164.msisdn contains "262090461004022"||e212.imsi
contains "262090461004022"||

esp contains "262090461004023"||sip contains "262090461004023" || diameter contains


"262090461004023"||e164.msisdn contains "262090461004023"||e212.imsi contains
"262090461004023"||

esp contains "262090461004024"||sip contains "262090461004024" || diameter contains


"262090461004024"||e164.msisdn contains "262090461004024"||e212.imsi contains
"262090461004024"||

esp contains "262090461004025"||sip contains "262090461004025" || diameter contains


"262090461004025"||e164.msisdn contains "262090461004025"||e212.imsi contains
"262090461004025"||

esp contains "262090461004026"||sip contains "262090461004026" || diameter contains


"262090461004026"||e164.msisdn contains "262090461004026"||e212.imsi contains
"262090461004026"||

http || gtpv2.message_type == 25 || gtpv2.message_type == 26 || gtpv2.message_type


== 27)

-----------------------------------------------------------------------------------
----

TEST CASE NAME: TO09.146- non VoLTE Nokia UC 3+2 Group - Call Forwarding change via
SCI from UC Slave 1, UC Slave 2 has ODB BAOC + ODB BAIC

Test Case Title: CF change via SCI from UC Slave 1, But UC Slave 2 has ODB BAOC +
ODB BAIC

PRE-REQUISITES:

- we have to choose Non Volte UC 3+2 group slave 1 ,2 and CLI cards
- we have to check before execution steps check all activation and barring status
- Slave 2 has been ODB BAOC + ODB BAIC in Slave 2 provisioining
- CLI cards not be activated any Services

- Take fresh Subscriber Profile logs in PGW GUI

Display PGW logs comment : ./display.sh 262090461004024

EXECUTION STEPS:

- We have to change CFB number in one of UC slave 1 card in PGW GUI


- SO in Slave 2 card get Quiscent state because of Barring of provisioning

EXPECTED RESULTS:

- NT HLR FE updates all 3 UC members of the non VoLTE Nokia UC 3+2 group

- NT HLR FE sends per member an ISD about the CF change

- TAS reads the MMTEL data via Restore Data message from Master.

- Take Subscriber post profile log in PGW CLI along with IMSI

WIRESHARK FILTER FOR RESULT EVALUATION:

-(esp contains "262090461004022"||sip contains "262090461004022" || diameter


contains "262090461004022"||e164.msisdn contains "262090461004022"||e212.imsi
contains "262090461004022"||

esp contains "262090461004023"||sip contains "262090461004023" || diameter contains


"262090461004023"||e164.msisdn contains "262090461004023"||e212.imsi contains
"262090461004023"||

esp contains "262090461004024"||sip contains "262090461004024" || diameter contains


"262090461004024"||e164.msisdn contains "262090461004024"||e212.imsi contains
"262090461004024"||

esp contains "262090461004025"||sip contains "262090461004025" || diameter contains


"262090461004025"||e164.msisdn contains "262090461004025"||e212.imsi contains
"262090461004025"||
esp contains "262090461004026"||sip contains "262090461004026" || diameter contains
"262090461004026"||e164.msisdn contains "262090461004026"||e212.imsi contains
"262090461004026"||

http || gtpv2.message_type == 25 || gtpv2.message_type == 26 || gtpv2.message_type


== 27)

-----------------------------------------------------------------------------------
---------------------------

TEST CASE NAME: TO09.147 - non VoLTE Nokia UC 3+2 Group - Call Forwarding change
via SCI - CLI Member

Test Case Title: CF change via SCI from UC CLI Slave card

PRE-REQUISITES:

- we have to choose Non Volte UC 3+2 group slave CLI card


- In one of UC group have already have activated CFB in Master or any Group card
- Check before execution of CLI Slave cards should be activated CFB
- Take fresh Subscriber Profile logs in PGW GUI

Display PGW logs comment : ./display.sh 262090461004026

EXECUTION STEPS:

- We have to change CFB number in one of UC CLI slave in PGW GUI


- SO in CLI Slave card Provisioning with ODB SS
- NT HLR FE will reject the corresponding MAP Messages
- Check the trace

EXPECTED RESULTS:

- NT HLR FE rejects the Call Forwarding data changes.


- Check Update location accept
- Check Send authentication info
- Check returnSS
- Check IP-SM-GW should be check activated or deactivated msg
-- Take Subscriber post profile log in PGW CLI along with IMSI

WIRESHARK FILTER FOR RESULT EVALUATION:

-esp contains "262090461004024"||sip contains "262090461004024" || diameter


contains "262090461004024"||e164.msisdn contains "262090461004024"||e212.imsi
contains "262090461004024"||

esp contains "262090461004025"||sip contains "262090461004025" || diameter contains


"262090461004025"||e164.msisdn contains "262090461004025"||e212.imsi contains
"262090461004025"||

esp contains "262090461004026"||sip contains "262090461004026" || diameter contains


"262090461004026"||e164.msisdn contains "262090461004026"||e212.imsi contains
"262090461004026"||

http || gtpv2.message_type == 25 || gtpv2.message_type == 26 || gtpv2.message_type


== 27)
-----------------------------------------------------------------------------------
------------------------------

TEST CASE NAME: TO09.148-non VoLTE Nokia UC 3+2 Group - Call Barring change via SCI
- UC Slave Member

Test Case Title: Call Barring change via SCI interface from UC Slave card

PRE-REQUISITES:

- we have to choose Non Volte UC 3+2 group slave card and should be activated
Barring
- we have to check status of SS and ODB Barring and forwarding all group cards
- Take fresh Subscriber Profile logs in PGW GUI

Display PGW logs comment : ./display.sh 262090461004024

EXECUTION STEPS:

- We have to change SS Call barring number for UC Slave card in PGW GUI

EXPECTED RESULTS:

- NT HLR FE updates all 3 UC member of the Nokia UC 3+2 group

- NT HLR FE sends per UC member an ISD about the CB change

- HSS sends notification to TAS. TAS reloads the MMTEL data update via Restore Data
Message

- Take Subscriber post profile log in PGW CLI along with IMSI

WIRESHARK FILTER FOR RESULT EVALUATION:

-(esp contains "262090461004022"||sip contains "262090461004022" || diameter


contains "262090461004022"||e164.msisdn contains "262090461004022"||e212.imsi
contains "262090461004022"||

esp contains "262090461004023"||sip contains "262090461004023" || diameter contains


"262090461004023"||e164.msisdn contains "262090461004023"||e212.imsi contains
"262090461004023"||

esp contains "262090461004024"||sip contains "262090461004024" || diameter contains


"262090461004024"||e164.msisdn contains "262090461004024"||e212.imsi contains
"262090461004024"||

esp contains "262090461004025"||sip contains "262090461004025" || diameter contains


"262090461004025"||e164.msisdn contains "262090461004025"||e212.imsi contains
"262090461004025"||

esp contains "262090461004026"||sip contains "262090461004026" || diameter contains


"262090461004026"||e164.msisdn contains "262090461004026"||e212.imsi contains
"262090461004026"||

http || gtpv2.message_type == 25 || gtpv2.message_type == 26 || gtpv2.message_type


== 27)
-----------------------------------------------------------------------------------
------------------------------
TEST CASE NAME: TO09.149-non VoLTE Nokia UC 3+2 Group - Call Barring change via SCI
- CLI Slave Member

Test Case Title: Call Barring change via SCI interface from UC CLI Slave card

PRE-REQUISITES:

- we have to choose Non Volte UC 3+2 group slave card and should be activated
Barring
- we have to check status of SS and ODB Barring and forwarding all group cards
- Take fresh Subscriber Profile logs in PGW GUI

Display PGW logs comment : ./display.sh 262090461004025

EXECUTION STEPS:

- We have to change SS Call barring number for UC CLI Slave card in PGW GUI
- We will get error during modification

EXPECTED RESULTS:

- NT HLR FE will reject the SCI request with an appropriate Error Code.

- We have to check trace ATM message

- Take Subscriber post profile log in PGW CLI along with IMSI

WIRESHARK FILTER FOR RESULT EVALUATION:

-(esp contains "262090461004022"||sip contains "262090461004022" || diameter


contains "262090461004022"||e164.msisdn contains "262090461004022"||e212.imsi
contains "262090461004022"||

esp contains "262090461004023"||sip contains "262090461004023" || diameter contains


"262090461004023"||e164.msisdn contains "262090461004023"||e212.imsi contains
"262090461004023"||

esp contains "262090461004024"||sip contains "262090461004024" || diameter contains


"262090461004024"||e164.msisdn contains "262090461004024"||e212.imsi contains
"262090461004024"||

esp contains "262090461004025"||sip contains "262090461004025" || diameter contains


"262090461004025"||e164.msisdn contains "262090461004025"||e212.imsi contains
"262090461004025"||

esp contains "262090461004026"||sip contains "262090461004026" || diameter contains


"262090461004026"||e164.msisdn contains "262090461004026"||e212.imsi contains
"262090461004026"||

http || gtpv2.message_type == 25 || gtpv2.message_type == 26 || gtpv2.message_type


== 27)
-----------------------------------------------------------------------------------
------------------------------

TEST CASE NAME: TO09.150-Nokia VoLTE Ultracard 3+2 group - UC Slave - CB change via
UT

Test Case Title: Call Barring change via UT interface from UC Slave card
PRE-REQUISITES:

- we have to choose Non Volte UC 3+2 group slave card and should be activated
Barring
- we have to check status of SS and ODB Barring and forwarding all group cards
- we have to verify all group of cards status of CB and CF status
- Take fresh Subscriber Profile logs in PGW GUI

Display PGW logs comment : ./display.sh 262090461004047

EXECUTION STEPS:

- We have to change SS Call barring number via UT interface for UC Slave card in
PGW GUI

EXPECTED RESULTS:

- NT HLR FE updates all 3 member of the Nokia UC group


- NT HLR FE sends per member an ISD about the CB change
- HSS sends notification to TAS.
- Take Subscriber post profile log in PGW CLI along with IMSI

WIRESHARK FILTER FOR RESULT EVALUATION:

-(esp contains "262090461004045"||sip contains "262090461004045" || diameter


contains "262090461004045"||e164.msisdn contains "262090461004045"||e212.imsi
contains "262090461004045"||

esp contains "262090461004046"||sip contains "262090461004046" || diameter contains


"262090461004046"||e164.msisdn contains "262090461004046"||e212.imsi contains
"262090461004046"||

esp contains "262090461004047"||sip contains "262090461004047" || diameter contains


"262090461004047"||e164.msisdn contains "262090461004047"||e212.imsi contains
"262090461004047"||

esp contains "262090461004048"||sip contains "262090461004048" || diameter contains


"262090461004048"||e164.msisdn contains "262090461004048"||e212.imsi contains
"262090461004048"||

esp contains "262090461004049"||sip contains "262090461004049" || diameter contains


"262090461004049"||e164.msisdn contains "262090461004049"||e212.imsi contains
"262090461004049"||

http || gtpv2.message_type == 25 || gtpv2.message_type == 26 || gtpv2.message_type


== 27)
-----------------------------------------------------------------------------------
------------------------------