Article
pubs.acs.org/journal/apchd5
radiation, α1 = α(λ1), and a much smaller absorption coefficient common approach to this problem is MC ray-tracing
at the wavelength (λ2) of the emitted light, α2 = α(λ2) (Figure simulations.12,20,41,42 While being accurate and versatile, they
1c). This suggests that the ratio of α1 and α2 might serve as a can, however, be computationally intense and time-consuming,
figure of merit or a quality factor of an LSC: QLSC = α1/α2. Here which complicates their use in the case of, for example, large-
we show that this quantity can indeed be used to directly scale structures.
evaluate the prospective LSC performance of a fluorophore. Here we attempt to develop a simple analytical approach for
Using a Monte Carlo (MC) ray-tracing simulation supple- an express evaluation of prospective performance of LSCs,
mented by an analytical model, we demonstrate that QLSC which could supplement MC simulations and in some cases
defines the ultimate concentration limit achievable with a given even replace them. In our model, we consider a planar device
fluorophore. Specifically, the ultimate optical concentration with dimensions L (length), W (width), and d (height), with
factor (C0), which is realized in the large-size limit, is directly 100% reflecting mirrors on the sidewalls (Figure 1b). We treat
proportional to QLSC, that is, C0 = FQLSC, where F ≈ 1 in the the top and bottom LSC surfaces as standard air/glass
case of ideal LSC emitters with the PL quantum yield (ηPL) of interfaces and assume perfect light outcoupling (100%
unity and semitransparent devices without back reflectors. transmission) at the left and right device sides terminated
Using our formalism, based on a QLSC factor, we can predict an with PVs. In this configuration, the output flux (Φ2) is a sum of
optimal slab absorptivity, which produces the maximum fluxes propagating in the left (Φ′2) and the right (Φ″2)
possible optical concentration for given LSC dimensions. directions (Φ2 = Φ′2 + Φ″2), while the output area is sum of
This capability is useful in the case of both semitransparent the areas of the device left and right edges (A2 = A′2 + A″2);
LSC windows and high-concentration devices aimed at Figure 1b. The geometric gain factor of this device is G =
replacing traditional mirror/lens-based systems. We verify the L/(2d).
predictions of the model by conducting measurements on LSCs The LSC optical efficiency can be expressed as ηopt = ηabsηcol,
containing visible-light emitting II−VI core/shell QDs with two where ηabs is the device absorptance (fraction of incident
distinct LSC quality factors. We also study devices that are photons that are absorbed by the LSC fluorophores) and ηcol is
based on near-infrared emitting CuInSexS2−x QDs. A large the collection efficiency (fraction of the absorbed photons that
emission bandwidth of these QDs allows us to evaluate the ultimately reach the output faces); ηcol can be thought of as an
affect of varied QLSC on the concentration factor by varying the internal quantum efficiency of an LSC, which defines the device
PL detection wavelength. Both studied QD systems have been efficiency per absorbed photon. The absorptance can be
recently utilized in practical demonstrations of high-perform- expressed via the reflection coefficient of the air/glass interface
ance LSCs.11,21−23,32 (R), and the absorption coefficient at the wavelength of
efficiency, which accounts for repeating reabsorption-reemis- by installing a fully reflecting mirror at the back of the
sion events. waveguide. This increases the device absorptance for incident
We start our analysis with the first-generation of PL photons radiation by doubling the light propagation path but at the
that are produced following the absorption of original incident same time preserves the geometric gain factor and the
light. The fraction of these photons, which is eventually collection efficiency. The net result of these changes is the
collected at the LSC edges, is directly linked to η(1) wg by ηcol =
(1)
increased concentration factor. In the case of a device with α1d
ηwg ηPLηtrap. The processes of reemission following absorption of
(1)
≪ 1, the back reflector increases the absorptance by a factor of
waveguided radiation will increase the overall collection 2, which leads to the following expression for the ultimate
efficiency and can be accounted for by summing the concentration factor for this device architecture with a fully
contributions from the second, third, etc., re-emission events. reflecting back side: C0,ref = 2FQLSC. For the situation of the air/
To account for the second-generation of reemitted photons glass interface at the front LSC surface, C0,ref ≈ 2.1QLSC.
(collection efficiency ηcol (2)
), we apply the first-generation Interestingly, when QLSC = 1, which corresponds to α1 = α2, the
collection efficiency η(1) col to the fraction of the photons (1 − above expression yields C0 of 2.1. This situation is somewhat
ηwg
(1)
) removed from the propagating modes by the first analogous to a slab comprising neutral scattering centers that
reabsorption event. This leads to η(2) col = ηPLηtrap(1 − ηwg )ηcol .
(1) (1) 4
randomize the direction of incident radiation without changing
Similarly, ηcol = [ηPLηtrap(1 − ηwg )] ηcol , ηcol = [ηPLηtrap(1 −
(3) (1) 2 (1) (4)
its wavelength. Such a system can indeed be employed in
η(1)
wg )] ηcol , and so on. Thus, each ηcol term represents a member
3 (1) (i)
LSCs;43,44 however, due to conservation of etendue its
of a geometric progression expressed as η(i) col = [ηPLηtrap(1 − concentration factor is limited by n2, that is, ∼ 2.25 in the
η(1)
wg )] ηcol . The total collection efficiency can be found as a
i−1 (1)
case of a glass or a polymer waveguide. This value is remarkably
sum of contributions due to all photon generations, ηcol = close to the one predicated by our model (Cmax = 2.1) for the
∑i ∞ = 1ηcol, which yields ηcol = ηcol [1 − ηPLηtrap(1 − ηwg )] .
(i) (1) (1) −1
case of QLSC = 1.
■
−1
Replacing ηwg with (1 + βα2L) as discussed earlier, we obtain
(1)
ηcol = ηPLηtrap[1 + βα2L(1 − ηPLηtrap)]−1. This leads to the COMPARISON TO MONTE CARLO RAY-TRACING
following expressions for the optical efficiency and the SIMULATIONS
concentration factor of a planar LSC: To validate the above derivations, we conduct MC ray-tracing
simulations (see SI, section 1) of devices depicted in Figure 1b
(1 − R )(1 − e−α1d)ηPLηtrap
ηopt = assuming a fixed thickness and width (d = W = 1) cm and a
1 + βα2L(1 − ηPLηtrap) (1)
varied length (L). We further set the optical density of the
device at the wavelength of incident light (λ1) to 0.1, which
corresponds to α1 = 0.23 cm−1. In Figure 2, we show the results
(1 − R )(1 − e−α1d)ηPLηtrap ⎛ L ⎞
C= ⎜ ⎟
of MC simulations (symbols) for the optical efficiency (panel
1 + βα2L(1 − ηPLηtrap) ⎝ 2d ⎠ (2)
“a”) and the concentration factor (panel “b”) as a function of L
for three values of QLCS (1, 10, and 100) and the ideal PL
According to eq 2, at small L when α2L ≪ 1, the quantum yield ηPL = 1. In the same figure, we also plot the
concentration factor is proportional to the device length, that results of the analytical model (lines) given by eqs 1 (ηopt) and
is, scales linearly with the geometric gain factor. However, when 2 (C). To match the model to MC simulations at short
α2L approaches unity and then exceeds it, the C-factor begins distances, we introduce a constant multiplier b, which in all
to saturate and asymptotically approaches the value given by cases is equal to 1.05 (see Figure S2 of SI). As was discussed
earlier, this accounts for a small (∼5% in this case)
(1 − R ) (1 − e−α1d) underestimation of the optical efficiency by the analytical
Csat = −1 −1
2β(ηPL ηtrap − 1) α2d model, which occurs as a result of the disregard of PL photons
(3)
produced by reabsorption events within the escape cone that
The maximum of Csat is realized when α1d approaches 0, are followed by reemission into the waveguided modes.
which defines an ultimate concentration limit (C0) attainable To describe the variation of ηopt with L, we have considered
with a given fluorophore for the device configuration shown in several values of β. With β = 1.4 (as derived from a fit to the
Figure 1b: Weber and Lambe model; Figure S1 of SI), analytical theory
(dashed lines in Figure 2a) provides a good description of the
(1 − R ) α1 results of the MC modeling for shorter distances (up to ∼100
C0 = −1 −1
= FQ LSC
2β(ηPL ηtrap − 1) α2 (4) cm), but deviates at larger L. On the other hand, the use, for
example, of β = 1.8 (dashed-and-dotted lines in Figure 2a)
where F = (1 − R)[2β(η−1 −1
PL ηtrap − 1)]
−1
is a numerical prefactor improves the agreement between the two models at large values
determined by the PL quantum yield and the refractive index of of L (up to ∼1000 cm), however, leads to some under-
the LSC slab; the latter defines R and ηtrap. In the case of ideal estimation of ηopt at shorter L, which is especially pronounced
emitters (ηPL = 1) and the glass/air interface (ηtrap = 0.75 and R for lower LSC quality factors (QLSC of 1−10). In order to better
= 0.04 for the normal incidence), F = 1.45/β or F ≈ 1, if β = capture the behavior of ηopt across the entire range of distances
1.4, as determined from the fit to the Weber and Lambe model used in our calculations, we have also considered the situation
(Figure S1 of SI). This indicates that the maximum of a distance-dependent parameter β. For example, using
concentration factor achievable with a given fluorophore is expression β = 1.4 + 0.5(L/150)1/2 (inset of Figure 2a), we
directly proportional to QLSC, and furthermore, in the case of have been able to obtain a nearly perfect match to the MC
the ideal quantum yield, it is approximately equal to the LSC modeling across the range of distances L = 0−2000 cm (solid
quality factor: C0 ≈ QLSC. lines in Figure 2a). We would like to caution, however, that this
If an LSC application does not require a semitransparent expression is of limited applicability, as at very large L, it leads
device, a simple approach to increase the concentration factor is to the unphysical behavior of the concentration factor, which
1141 DOI: 10.1021/acsphotonics.6b00307
ACS Photonics 2016, 3, 1138−1148
ACS Photonics Article
■
QLSC = 10 and four quantum yields of the LSC fluorophores: 50%
(green), 70% (black), 90% (red), and 100% (blue); same device
dimensions and transmission coefficient as in Figure 2. The inset of EXPERIMENTAL STUDIES OF LSC PERFORMANCE
panel “b” shows the dependence of the saturated concentration factor AS A FUNCTION OF LSC QUALITY FACTOR
(Csat) on ηPL based on the analytical model (red solid line) and MC In the experimental part of this work, we investigated two
simulations (symbols). The dependence of Csat on ηPL changes from samples of visible-light (yellow and red) emitting II−VI core/
nearly linear at low values of ηPL (black dashed line) to nearly shell QDs and a near-infrared emitting sample of CuInSexS2−x
quadratic (black solid line) at higher values of ηPL. Dashed colored
lines in panel ‘c’ show the calculations for ηPL = 90% and QLSC = 18
QDs (x ≈ 1); see section 2 of SI for details of the syntheses and
(red) and ηPL = 70% and QLSC = 108 (black); these calculations samples’ characterization. QDs were dissolved in toluene and
illustrate that the drop in the PL quantum yield can be mitigated by loaded into 4.0 × 1.0 × 0.5 cm3 optical cells that were studied
increasing QLSC, which could allow for increasing the practical device as “liquid LSCs” with a geometric gain factor G = 4. The
dimensions to the same value as for the ideal emitters with ηPL = 100%, samples were excited at λ1 = 532 nm by an expanded beam of a
but a lower LSC quality factor. continuous wave diode laser, which provided a spatially uniform
1143 DOI: 10.1021/acsphotonics.6b00307
ACS Photonics 2016, 3, 1138−1148
ACS Photonics Article
∫ SPL(λ)α(λ)dλ
⟨α2⟩ =
∫ SPL(λ)dλ (7)
Figure 5. continued the LSC performance can be optimized to maximize ηopt and C
by adjusting the absorption coefficient for incident light. We
Vertical red bars mark the peak values of optical efficiencies and find that Cmax realized in this case also scales directly with QLSC,
optimal values of α1d for which they are realized. (c) Maximum however, slower than in the C0 case. Specifically, both
concentration factor (Cmax) vs QLSC as inferred from the measurements measurements and calculations indicate that in the range of
(symbols) in comparison to calculations (red solid line); in the range small and moderately high QLSC-factor (QLSC < 20−30), the
of QLSC < 20−30, the observed trend can be approximated by the dependence of C on QLSC can be approximated by a square-
square-root dependence (red dashed line). The black dashed-and- root function. The results of this work provide quantitative
dotted line shows values of (α1d)opt that correspond to Cmax. The blue guidelines for predicting LSC efficiencies based on optical
solid line is an ultimate concentration factor, C0 (see eq 4), as a properties of LSC fluorophores and the geometry of the LSC
function of QLSC.
waveguides. This should aid in the development of practical
devices for applications as both semitransparent PV windows
and then directly relate them to experimental values of QLSC and nearly opaque high-concentration systems.
varied by changing the detection wavelength (Figure 5c,
symbols). We also calculate theoretical values of Cmax based on
eq 2. To do so, we first find an optimal value of optical density,
■ METHODS
Optical Characterization. Different concentrations of
(α1d)opt, which maximizes C for a given QLSC (black dashed- QDs were prepared in toluene and loaded into 4.0 × 1.0 ×
and-dotted line in Figure 5c), and then use it to compute Cmax 0.5 cm3 quartz fluorimeter cuvettes (Starna, 23-Q-5). Toluene
(red solid line in Figure 5c). The theory once again is in a very was chosen over other solvents to more closely match the index
close agreement with the experimental findings. Both sets of of the quartz cuvette and thus minimize any effects due to
data show direct scaling of Cmax with QLSC. In the range of low refractive index mismatch. Absorption spectra of the samples
and moderate quality factors (QLSC up to ∼20), this scaling can were taken on a diode array UV−vis spectrometer. Emission
be approximated by a square-root dependence (red dashed from QD samples was excited with a continuous-wave 532 nm
line), while for higher QLSC, the concentration shows signs of diode laser (LaserGlow). The pump beam was expanded to the
saturation reaching the maximum of ∼0.5 at QLSC = 74.2. We 1″ size by a Newtonian telescope and then transmitted through
would like to point out that Cmax inferred from our a 2″ aspheric condenser with a diffuser (Thorlabs, ACL504OU-
measurements of small-size LSCs are different from the DG6) to produce a large area collimated light source to
ultimate concentration factors (C0; eq 4) realized in the long- uniformly illuminate the 4.0 × 1.0 cm2 side of the cuvette. The
LSC limit when α2L = α1d(QLSC)−1 ≫ 1. To highlight this spatial uniformity of the illumination was verified by translating
difference, we show C0 derived from eq 4 for the parameters of a 1 cm diameter power meter in the sample plane. The power
our CISexS1−x QD sample in Figure 5c (blue solid line). As was was found to fluctuate by less than 5% across the sample
discussed earlier, C0 scales linearly with QLSC and is excitation area. The incident power was attenuated with neutral
considerably higher than the values realized in the studied density filters to 1−10 mW/cm2 at the sample surface.
small size LSCs. For example, the ultimate concentration limit
The cuvette with QDs was held vertically by a specially
for this type of the QDs realized for QLSC = 74.2 is ∼26.
designed holder that allowed for direct mounting onto the
To summarize, we have used QD-based LSCs to analyze
integrating sphere entrance port while minimally obscuring the
optical efficiencies (ηopt) and concentration factors (C) in
excitation area. In this manner, light incident on the largest area
relation to an LSC quality factor defined as the ratio of
surface of the cuvette was absorbed by the QDs and the
absorption coefficients at the wavelengths of incident and
fluorescence escaping the bottom surface was directed into one
emitted light: QLSC = α1/α2. In this analysis, we utilize an
port of an 8″ integrating sphere (Labsphere). The PL intensity
analytical model, which allows us to quantify LSC performance
was measured using a second port, which was equipped with a
(e.g., in terms of ηopt and C) based on QLSC, PL quantum yield,
fiber optic coupler connected to a spectrometer (Ocean Optics,
geometric gain factor, and the device absorptivity at the
JAZZ). The spectral sensitivity of the joint instrument
wavelength of the incident light. We find that, in all of the
(spectrometer, fiber, and integrating sphere) was calibrated
considered cases, this theory is in excellent agreement with
using the output of a standard light source (certified, white light
numerical MC ray-tracing simulations. However, as compared
Tungsten bulb).
■
to the computationally intense MC modeling, the analytical
allows for a much faster evaluation of prospective performance
of LSCs based on the optical spectra of light emitting ASSOCIATED CONTENT
fluorophores and geometrical parameters of the LSC slabs. *
S Supporting Information
This greatly simplifies analysis of experimental data and can, in The Supporting Information is available free of charge on the
principle, help in the optimization of both the optical properties ACS Publications website at DOI: 10.1021/acsphoto-
of LCS fluorophores and the waveguide design in practical nics.6b00307.
devices.
The analysis of both theoretical and experimental data QD sample fabrication procedures, characterization of
indicates that the concentration factor scales directly with the the QD samples using transmission electron microscopy,
LSC quality factor. Specifically, we show that the ultimate analytical and Monte Carlo modeling of optical
concentration limit (C0) realized in large-size LSCs (α2L ≫ 1) efficiencies of luminescent solar concentrators as a
is directly proportional to QLSC, and in the case of perfect function of device length and optical density for varied
emitters (ηPL = 100%) and the simplest LSC design, which does photoluminescence quantum yields, derivation of
not employ selective reflectors on the top of the structure or correction factors for relating optical efficiencies of
fully reflecting mirrors on its back side, C0 ≈ QLSC. We also devices with perfectly reflecting sidewalls to those with
consider the case of a fixed LSC size and a given QLSC, where uncoated glass sidewalls, and the measurements of a
1146 DOI: 10.1021/acsphotonics.6b00307
ACS Photonics 2016, 3, 1138−1148
ACS Photonics Article
spectrally resolved PL intensity as a function of optical R. E. I.; Donega, C. D. Tackling Self-Absorption in Luminescent Solar
density of the CuInSexS2−xQD sample (PDF). Concentrators with Type-II Colloidal Quantum Dots. Sol. Energy
■
Mater. Sol. Cells 2013, 111, 57−65.
(17) Erickson, C. S.; Bradshaw, L. R.; McDowall, S.; Gilbertson, J. D.;
AUTHOR INFORMATION Gamelin, D. R.; Patrick, D. L. Zero-Reabsorption Doped-Nanocrystal
Corresponding Author Luminescent Solar Concentrators. ACS Nano 2014, 8, 3461−3467.
*E-mail: klimov@lanl.gov. (18) Bronstein, N. D.; Yao, Y.; Xu, L.; O’Brien, E.; Powers, A. S.;
Notes Ferry, V. E.; Alivisatos, A. P.; Nuzzo, R. G. Quantum Dot Luminescent
The authors declare no competing financial interest. Concentrator Cavity Exhibiting 30-Fold Concentration. ACS Photonics
■
2015, 2, 1576−1583.
ACKNOWLEDGMENTS (19) Bronstein, N. D.; Li, L.; Xu, L.; Yao, Y.; Ferry, V. E.; Alivisatos,
A. P.; Nuzzo, R. G. Luminescent Solar Concentration with
This work was supported by the Center for Advanced Solar Semiconductor Nanorods and Transfer-Printed Micro-Silicon Solar
Photophysics (CASP), an Energy Frontier Research Center Cells. ACS Nano 2014, 8, 44−53.
funded by the U.S. Department of Energy, Office of Science, (20) Sahin, D.; Ilan, B.; Kelley, D. F. Monte-Carlo Simulations of
Basic Energy Sciences.
■
Light Propagation in Luminescent Solar Concentrators Based on
Semiconductor Nanoparticles. J. Appl. Phys. 2011, 110, 033108.
REFERENCES (21) Meinardi, F.; Colombo, A.; Velizhanin, K. A.; Simonutti, R.;
(1) Weber, W.; Lambe, J. Luminescent Greenhouse Collector for Lorenzon, M.; Beverina, L.; Viswanatha, R.; Klimov, V. I.; Brovelli, S.
Solar Radiation. Appl. Opt. 1976, 15, 2299−2300. Large-Area Luminescent Solar Concentrators Based on ‘Stokes-Shift-
(2) Hermann, A. M. Luminescent Solar Concentrators - a Review. Engineered’ Nanocrystals in a Mass-Polymerized PMMA Matrix. Nat.
Sol. Energy 1982, 29, 323−329. Photonics 2014, 8, 392−399.
(3) Batchelder, J. S.; Zewail, A. H.; Cole, T. Luminescent Solar (22) Coropceanu, I.; Bawendi, M. G. Core/Shell Quantum Dot
Concentrators 0.2. Experimental and Theoretical-Analysis of Their Based Luminescent Solar Concentrators with Reduced Reabsorption
Possible Efficiencies. Appl. Opt. 1981, 20, 3733−3754. and Enhanced Efficiency. Nano Lett. 2014, 14, 4097−4101.
(4) Batchelder, J. S.; Zewai, A. H.; Cole, T. Luminescent Solar (23) Bradshaw, L. R.; Knowles, K. E.; McDowall, S.; Gamelin, D. R.
Concentrators 0.1. Theory of Operation and Techniques for Nanocrystals for Luminescent Solar Concentrators. Nano Lett. 2015,
Performance Evaluation. Appl. Opt. 1979, 18, 3090−3110. 15, 1315−1323.
(5) van Sark, W. G. J. H. M.; Barnham, K. W. J.; Slooff, L. H.; (24) Wang, C. H.; Shcherbatyuk, G.; Inman, R.; Pelka, D.; Zhang, W.
Chatten, A. J.; Buchtemann, A.; Meyer, A.; McCormack, S. J.; Koole, Y.; Rodriguez, Y.; Carter, S.; Winston, R.; Ghosh, S. Efficiency
R.; Farrell, D. J.; Bose, R.; Bende, E. E.; Burgers, A. R.; Budel, T.; Improvement by Near Infrared Quantum Dots for Luminescent Solar
Quilitz, J.; Kennedy, M.; Meyer, T.; Donega, C. D. M.; Meijerink, A.; Concentrators. Proc. SPIE 2010, 7772, 77720G−77726G.
Vanmaekelbergh, D. Luminescent Solar Concentrators - a Review of (25) Sholin, V.; Olson, J. D.; Carter, S. A. Semiconducting Polymers
Recent Results. Opt. Express 2008, 16, 21773−21792. and Quantum Dots in Luminescent Solar Concentrators for Solar
(6) Debije, M. G.; Verbunt, P. P. C. Thirty Years of Luminescent Energy Harvesting. J. Appl. Phys. 2007, 101, 123114.
Solar Concentrator Research: Solar Energy for the Built Environment. (26) Aldakov, D.; Lefrancois, A.; Reiss, P. Ternary and Quaternary
Adv. Energy Mater. 2012, 2, 12−35. Metal Chalcogenide Nanocrystals: Synthesis, Properties and Applica-
(7) Rau, U.; Einsele, F.; Glaeser, G. C. Efficiency Limits of tions. J. Mater. Chem. C 2013, 1, 3756−3776.
Photovoltaic Fluorescent Collectors. Appl. Phys. Lett. 2005, 87, (27) Yarema, O.; Bozyigit, D.; Rousseau, I.; Nowack, L.; Yarema, M.;
171101. Heiss, W.; Wood, V. Highly Luminescent, Size- and Shape-Tunable
(8) Markvart, T. Detailed Balance Method for Ideal Single-Stage Copper Indium Selenide Based Colloidal Nanocrystals. Chem. Mater.
Fluorescent Collectors. J. Appl. Phys. 2006, 99, 026101. 2013, 25, 3753−3757.
(9) Shockley, W.; Queisser, H. J. Detailed Balance Limit of Efficiency (28) Li, L.; Daou, T. J.; Texier, I.; Tran, T. K. C.; Nguyen, Q. L.;
of p-n Junction Solar Cells. J. Appl. Phys. 1961, 32, 510−519. Reiss, P. Highly Luminescent CuInS2/Zns Core/Shell Nanocrystals:
(10) Chemisana, D. Building Integrated Concentrating Photo- Cadmium-Free Quantum Dots for in Vivo Imaging. Chem. Mater.
voltaics: A Review. Renewable Sustainable Energy Rev. 2011, 15,
2009, 21, 2422−2429.
603−611.
(29) Pietryga, J. M.; Werder, D. J.; Williams, D. J.; Casson, J. L.;
(11) Meinardi, F.; McDaniel, H.; Carulli, F.; Colombo, A.;
Schaller, R. D.; Klimov, V. I.; Hollingsworth, J. A. Utilizing the Lability
Velizhanin, K. A.; Makarov, N. S.; Simonutti, R.; Klimov, V. I.;
of Lead Selenide to Produce Heterostructured Nanocrystals with
Brovelli, S. Highly Efficient Large-Area Colourless Luminescent Solar
Concentrators Using Heavy-Metal-Free Colloidal Quantum Dots. Nat. Bright, Stable Infrared Emission. J. Am. Chem. Soc. 2008, 130, 4879−
Nanotechnol. 2015, 10, 878−885. 4885.
(12) Leow, S. W.; Corrado, C.; Osborn, M.; Carter, S. A. Monte (30) Semonin, O. E.; Johnson, J. C.; Luther, J. M.; Midgett, A. G.;
Carlo Ray-Tracing Simulations of Luminescent Solar Concentrators Nozik, A. J.; Beard, M. C. Absolute Photoluminescence Quantum
for Building Integrated Photovoltaics. Proc. SPIE 2013, 8821, 882103− Yields of IR-26 Dye, PbS, and PbSe Quantum Dots. J. Phys. Chem. Lett.
882107. 2010, 1, 2445−2450.
(13) Bomm, J.; Büchtemann, A.; Chatten, A. J.; Bose, R.; Farrell, D. (31) Li, L. A.; Pandey, A.; Werder, D. J.; Khanal, B. P.; Pietryga, J. M.;
J.; Chan, N. L. A.; Xiao, Y.; Slooff, L. H.; Meyer, T.; Meyer, A.; van Klimov, V. I. Efficient Synthesis of Highly Luminescent Copper
Sark, W. G. J. H. M.; Koole, R. Fabrication and Full Characterization Indium Sulfide-Based Core/Shell Nanocrystals with Surprisingly
of State-of-the-Art Quantum Dot Luminescent Solar Concentrators. Long-Lived Emission. J. Am. Chem. Soc. 2011, 133, 1176−1179.
Sol. Energy Mater. Sol. Cells 2011, 95, 2087−2094. (32) Li, C.; Chen, W.; Wu, D.; Quan, D. H.; Zhou, Z. M.; Hao, J. J.;
(14) Currie, M. J.; Mapel, J. K.; Heidel, T. D.; Goffri, S.; Baldo, M. A. Qin, J.; Li, Y. W.; He, Z. B.; Wang, K. Large Stokes Shift and High
High-Efficiency Organic Solar Concentrators for Photovoltaics. Science Efficiency Luminescent Solar Concentrator Incorporated with
2008, 321, 226−228. CuInS2/ZnS Quantum Dots. Sci. Rep. 2015, 5, 17777.
(15) Gallagher, S. J.; Rowan, B. C.; Doran, J.; Norton, B. Quantum (33) Rice, W. D.; McDaniel, H.; Klimov, V. I.; Crooker, S. A.
Dot Solar Concentrator: Device Optimisation Using Spectroscopic Magneto-Optical Properties of CuInS2 Nanocrystals. J. Phys. Chem.
Techniques. Sol. Energy 2007, 81, 540−547. Lett. 2014, 5, 4105−4109.
(16) Krumer, Z.; Pera, S. J.; van Dijk-Moes, R. J. A.; Zhao, Y. M.; de (34) Yablonovitch, E. Thermodynamics of the Fluorescent Planar
Brouwer, A. F. P.; Groeneveld, E.; van Sark, W. G. J. H. M.; Schropp, Concentrator. J. Opt. Soc. Am. 1980, 70, 1362−1363.