You are on page 1of 2

Primers & Coatings

Ultrafill
A high adhesion aerosol based 1k primer filler, available in 6 colours, with fast drying and excellent sanding
properties.

Part Nº:
84075 (UFL-BLK) - Ultraf ill Black 500ml Aerosol
84076 (UFL-W) - Ultraf ill White 500ml Aerosol
84077 (UFL-Y ) - Ultraf ill Y ellow 500ml Aerosol
84078 (UFL-BLU) - Ultraf ill Blue 500ml Aerosol
84079 (UFL-R) - Ultraf ill Red 500ml Aerosol
84167 (UFL-G) - Ultraf ill Grey 500ml Aerosol

Features Benefits
• One component product • No mixing required
• Match primer base to final colour • Less base colour required
• High solid content • Fills fast & saves material
• Extremely good coat depth • Good fill & build qualities
• Very flexible • Flexes with plastic & metal components
• Compatible with all leading automotive paints, • No comebacks
incl. water based
• Good adhesion to all surfaces • No comebacks
• Dries fast - 20 minutes • Saves time
• Will resist wipe off when using panel wipe • Easier to prep
• 6 colours available • Meets needs for all colours

Application Method (please note that due to the fast drying time of this product, if too
Due to its high adhesion Ultrafill is the ideal solution to primer heavy a coat is applied then it is possible for solvent to become
filling surfaces prior to painting on plastic or metal substrates. trapped between coats, causing paint defects at a later stage). To
It is ideal for small repair areas such as minor accident achieve a fast finish, it is imperative that 3-4 lighter coats are
damage, rub through’s when flatting, or small components applied as opposed to 1-2 heavy coats. Heavy coats will trap
such as mirror housings. Application areas for Ultrafill are on solvent and considerably slow down the curing process. In most
almost any metal or plastic surfaces. The list below is cases, for a keyed panel 3 coats should be sufficient. It is
comprehensive, but by no means exhaustive: - recommended that coat depth does not exceed 100 > 120 micron
• Bonnet and boots; Wings, quarter panels and doors; ‘A’, ’B’ and for best results including best time for repair completion.
‘C’ posts; Roofs; Bumpers; Side mirror housings. 4. It is possible to build very heavy coats but this is only advised in
small local areas for pit filling, due to extended drying times
Instructions for use required.
5. It is also important to invert can after application of a coat spray
Preparation briefly to clear the spray head.
1. Area to be painted should be final flatted with P180 or P240 Drying time
2. Clean repair area with either Acrysol or Panel wipe. Allow to 1. Drying times are dependant on ambient temperatures, but are
Dry generally:- Air-Dried -15-20 minutes
3. Shake the Ultrafill aerosol can. It is important that the can is Infra red/Oven baked - 5-10 minutes
shaken for a minimum of 1 minute from the time that the ball 2. If no heat or other UV type of drying aid is available, the drying
starts moving. time can be reduced by passing air over the painted surface
Painting 3. Heavy coats or many fast-applied coats will take between 30 to 45
1. Hold can approximately 15 to 20 cm from the panel. min to dry unless forced with heat
2. Apply first coat to panel ensuring full but not heavy coating, Flatting
using a steady movement of the can with an overlapping 1. Flatting in preparation for final colour coating can be with either dry
spray action, ensuring a fully wet coat. paper or wet and dry (P320 or finer)
3. Allow 1 to 2 min between coats dependent on ambient After flatting, use panel wipe or Acrysol to clean and degrease
conditions. Shake the can between coats. The second coat surface in preparation for overcoating.
can be applied more heavily, building up in required areas

Hints & Tips


Due to the high solid contents, ensure that the product is fully shaken as per the use
instructions before spraying. If a thick/heavy coverage is required, this is best achieved
by building up the coverage with more coats of a regular thickness as opposed to fewer but
DS70 heavy coats. Allowing the coats to flash off before applying the next coat will allow solvent
to dissipate from the product, and not become trapped between layers.

0066 01
Primers & Coatings
Ultrafill
Technical Information
Part Number: 84075; 84076; 84077; 84078; Stock Code: UFL-BLK; UFL-W; UFL-Y;

84079; 84167 UFL-BLU; UFL-R; UFL-G

Description: Ultrafill, 500ml aerosol Custom Tariff Code: 3208 2090

Shelf Life: 24 months MSDS: Yes

Selling Unit: Each Replacing Product: None

Hazard info: Extremely Flammable; Irritant Consistency: Thick liquid

Colours: Black; White; Yellow; Blue; Red; Grey

VOC ULTRAFILL WHITE 2004/42/IIB(e)(840)651 ULTRAFILL RED 2004/42/IIB(e)(840)652


Markings: ULTRAFILL YELLOW 2004/42/IIB(e)(840)654 ULTRAFILL GREY 2004/42/IIB(e)(840)652
ULTRAFILL BLUE 2004/42/IIB(e)(840)654 ULTRAFILL BLACK 2004/42/IIB(e)(840)654

Associated Body f illers; Acry sol; Plastic repair sy stem; Waterproof and dry abrasiv e paper.
Products:

Primary Secondary
Market
Segments

Health & Safety Information


R36 Irritating to eyes.
R66 Repeated exposure may cause skin dryness or cracking.
F+ R67 Vapours may cause drowsiness and dizziness.
HIGHLY S16 Keep away from sources of ignition - No smoking.
S23 Do not breathe fumes/aerosol.
FLAMMABL S25 Avoid contact with eyes.
E S26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
S37 Wear suitable gloves.
Xi S51 Use only in well-ventilated areas.
IRRITANT WARNING: Pressurised container: protect from sunlight and do not expose to temperatures exceeding
50°C. Do not pierce or burn, even after use. Do not spray on a naked flame or any incandescent material.

In order to provide you with the most appropriate Personal Protective Equipment when using our products, KENT advises that you follow
the guidelines on the packaging of the product before use. The guidelines are there for your protection and KENT provides a range of
Personal Protection Equipment such as clothing, eye glasses, goggles, face shields and breathing apparatus, complying with the latest
European legislation. If you require further advice then please phone our freephone number and we will be pleased to help you.
Telephone: 0800 136925

Terms and Conditions The Information is subject to change without notice and liability resulting from negligence or where the Group was aware of
No part of this publication may be reproduced, replaces all data sheets previously supplied. The the possibility of such loss or damage arising) is excluded. This
transmitted or stored, electronically, mechanically or Information supplied is believed to be accurate but the will not operate to limit or restrict the Group's liability for death or
photocopied without the prior permission of Barnes Group assumes no responsibility for its accuracy or personal injury resulting from its negligence KENT is the trading
Group KENT Ltd. completeness, any error from or omission in it nor for name of Barnes Group KENT Ltd.
This data sheet and its contents (the "Information") any use made of it. Users of this data sheet should
check for themselves the Information and the suitability Registered Office:
belong to the Barnes Group KENT Ltd or are 36-48 Queen Street, Horsham, West Sussex RH13 5AD
licensed to it. No licence is granted for the use of it of the products for their purpose and not make any
assumptions based on information included or omitted. Registered in England Nº: 1164516
other than for information purposes in connection VAT Registration Nº: 887 1228 94
with the products to which it relates. No licence of Liability for loss or damage resulting from any reliance on
the Information or use of it (including All rights reserved.
any intellectual property rights is granted.

KENT UK: 36 – 48 Queen Street, Horsham, West Sussex, RH13 5AD DS70
Tel: +44 (0) 1403 213355 Fax: +44 (0) 1403 213343 www.kenteurope.com
Barnes Group KENT Ltd 2006

You might also like