1000 kVA Temp-Rise Reports

You might also like

You are on page 1of 13
CPRI TEST REPORT Central Power Research Institute (A Govt. of India Society) P.B.No. 8066, Sadashivanagar Post Office, a“ Sir C.V. Raman Road, Bengaluru - 560 080 (INDIA) CENTRAL POWER RESEARCH INSTITUTE. (Member of STL) TEST REPORT CPRI Test Report Number : CPRIBLRSCL20T0525 Date: 20 October 2020 Name & Address of the Customer Name & Address of the Manufacturer Particulars of sample tested : Type Description of the test sample Serial Number (5) Number of Samples tested Date(s) of Test(s) CPRI sample code Number(s) Particulars of tests conducted Test in accordance with Standard / specification Sampling plan ¢ Customor's requirement Deviations if any i Name of the witnessing persons Customer's representativ. : Other than customer's representative Test subcontracted with address of the laboratory Documents constituting this roport (In wores) Number of Sheet(s) Number of Oscillogram(s) Number of Graphs) Number of Photograph(s) Number of Test Circuit Diagram(s) Number of Drawing(s) Mis. Shirdi Sai Electricals Lid 13/82, Industrial Estate, Kadapa — 616 004, Andhra Pradesh, india Mis. Shirai Sai Electricals Ltd 13/82, Industrial Estate, Kadapa~ 516 004 Andhra Pradesh, india 1000 kVA, 20000/400 V, Three Phase Distribution Transformer Outdoor, oil immersed Refer Sheet 2 of & SSE/000/PT-0325 ‘One 30 September, 5 0 7 October, 2020 Hvo20S0483, 1) Temperature rise 2) Determination of sound levels 3) Measurement of ze’o- sequence impedance on three phase transformers Clause 7 of IEC 60076-22011, IEC 6076-10; 2016 & Subclause 11.6 of IEC 60076-1 : 2011 Not applicable Nil Nil Mr. N. Harinath Reday None None Eignt Nil Two Nil Nil Discipline: Electrical Testing Group: Inductors & Transformers Two Jer Prete) ae (ow cb) Test Enginoor Head of Division bs ‘Approved by E ri ULR-T5452200SCLTO525F SHORT CIRCUIT LABORATORY Sheot 1 of 8 .BNO.8005, SADASHIVANAGAR POST OFFICE SIR C\V.RAMAN ROAD, BENGALURU - £80 089 INDIA) Phone +91 (0) 80 ~22072353 Fax: +91 (0) 80 -23601213 CENTRAL POWER RESEARCH INSTITUTE. (Member of STL) TEST REPORT Test Report Number: CPRIBLRSCL20T0525 Date: 20 October 2020 DESCRIPTION OF SAMPLE TESTED (As assigned by the manufacturer) Test sample + Distribution Transformer Type + Outdoor, cil immersed Serial number SSE/000/PT-0325 Rated power 4000 kVA Rated voltage - HV / LV 20000 / 400 V Insulation levels HV LIJAC + 125/50 kV LV LAC 3 -/MOKV Guaranteed impedance volt at 75 °C 2 6.0% Number of phases : Three Rated frequency 2 50 Hz Vector group Dyn 11 Taps 5 (- 5% to + 5% in steps of 2.5%) Type of cooling : ONAN - No-load loss at rated voltage at principal tapping and at rated frequency : 693 W (max) Load loss at rated current at principal tapping at 75°C 7600 W (max) Coil + Copper conductor, non-circular Core material : CRGO Guaranteed sound power limit : 55 dB(A) Month & Year of Manufacture September 2020 Weight of oil 2 B10L a (CL. Prakash) Test Engineer ULR-TC5452200SCLT0525F ‘SHORT CIRCUIT LABORATORY Sheet 2 of 8 Discipline: Electrical Testing '.8.NO 8068, SADASHIVANAGAR POST OFFICE Group: Inductors & Transformers _ SiR C.V RAMAN ROAD, BENGALURU - 860 080 (NDIA) Phone +91 (0) 80- 22072353 Fax: +91 (0) €0- 23601213 CENTRAL POWER RESEARCH INSTITUTE (Member of STL) TEST REPORT Test Report Number: CPRIBLRSCL20T0525 Date: 20 October 2020 SUMMARY OF TESTS conpucTeD 1. Tests conducted + Refer the table below 2. Rating for which tested + Refer Sheet 5 of 8 to Sheet 7 of 8 3. Schedule of tests 3 His Tests Conducted Clause Numbers Sheet | | No. == = pai __Temperature ise 7 of IEC 60076-20017 Sof8 a Determination of sound levels IEC 6076-10: 2076 bore 3] Measurement of zaro- ace | 11.6 oF IEC 60076-42077 Tote | Impedance on three phase _transformers = J 4. Graph Number(s) -PRIBLRSCL20T0525G0; & CPRIBLRSCL20T0525G02 5. Drawing Number(s) # Refer Sheet 4 of @ a AEC Prevesty st Engineer ' ULR-Tes4s22008cL Tos25F SHORT CIRCUIT LABORATORY Sheet 3 of Discipline: Electrical Testing P-BNO 806s, SADASHIVANAGAR POST OFFICE Group: auctors & Transformers sinc vnanen ROAD, BENGALURU - 60089 INDIA) Prone #81 (0) 60. 22072353 Fax: v91 a0 ann CENTRAL POWER RESEARCH INSTITUTE (Member of STL) TEST REPORT Date; 20 October 2020 Test Report Number: CPRIBLRSCL20T0525 LIST OF DRAWINGS Drawing Numbers The manufacturer has guaranteed that the sample submitted for the test(s) has been manufactured in accordance with the following drawings [SL.No. Drawing Number Sheet Number | Revision Number . 1 ‘4 RP 7039 = 3 2 3.0G 9495. - Itis verified that these drawings adequately represent the sample tested. Verification of this drawing by CPRI is limited to dimensional check only wherever possiole. ak, AE Prakash) Test Engineer ULR-T05452200SCLT0525F ‘SHORT CIRCUIT LABORATORY Sheet 4 of 8 Discipline: Electrical Testing P.5.NO.8068, SADASHIVANAGAR POST OFFICE Group: Inductors & Transformers _ SIR.CV RAMAN ROAD, BENGALURU - 60 080 (NDIA) ‘nana 204 (0 0-22072353, Fax: +91 (0) 80- 29601213 CENTRAL POWER RESEARCH INSTITUTE. (Momber of STL) TEST REPORT ‘Test Report Number: CPRIBLRSCL20T0525 1. TEMPERATURE RISE TEST ‘TEST RESULTS Date: 20 October 2020 AAs after offload tap switch operated 200 times manually from Condition of the sample: position 1 to postion 5 and fom position & fo positon 1 Test method Short-circuit Test conditions Source Phases Thee Frequency (He) 50 sample RV terminals Connected to three phase source LV terminals Shorted through copper links of negligible resistance Measured Losses ‘No load loss at rated voltage and at rated frequency (WW) Load loss at rated current at 75° C at principal tap (W) Test Procedure: Step 1 - Total loss (7700.8 W) was injected until a steady state of top oil temperature rise is established Step 2 - Injection of the rated current (28.87 A) for one hour, immediately after step-1 638.81 7061.99 The values of hot resistance of HV and LV windings at the time of shutdown are given in graphs CPRIBLRSCL20T0525G01 & CPRIBLRSCL20T0525G02 respectively Ambient temperature: 24.4° C Discipline: Electrical Testing P.B.NO.066, SADASHIVANAGAR POST OFFICE Measured | Tomporature-rise —] Temperature-riso | Limitas por | Observations Points (K) limit declared by | the standard manufacturer (K) rt Top oil Ag Ai(Anerator)) 55 60 Within limits veaing | 528 fy resistance method HV winding |, after step 2) 60 65 Within limits nang | 545 (hy resistance method Fi LV winding ae 0 65 | Within timits or gbete ent, Feet Brakash) ‘Test Engineer ULR-TC5452200SCLT0525F SHORT CIRCUIT LABORATORY Sheet 5 of 8 CENTRAL POWER RESEARCH INSTITUTE, (Member of STL) TEST REPORT ‘Test Report Number: CPRIBLRSCL20T0525 Date: 20 October 2020 2. DETERMINATION OF SOUND LEVELS Test conditions Transformer was excited under no-load condition with rated voltage of 400 V at secondary winding and at rated frequency. Distance of measurement from test ‘equipment is 0.3 m. Measurement was made at half height of transformer at 0.63 m Measurement ] Back ground noise level | Combined noise level of Position (As | before measurement of | background plus transformer per outline) | audible sound level of | excited by rated voltage at | audible sound level of transformer dB (A) no load condition dB(A) __| transformer dB (A) 1 292 342 20.6 2 29.0 340 29.9 3 28.9 308 20.2 = 4 29.0 35.0 30.4 6 28.4 337 204 a 288 aT 298 7 23.8 310 298 8 307 36.0 30.1 a 28 B27 238 10 302 362 30.2 1 288 339 30.0 zi 2 284 340 29.8 Uncorrected Average A-weighted Sound Pressure Level 33.9 dB (A) ‘Acweighted Background noise pressure level before measurement of audible sound level of transformer 29.3 0B (A) ‘Acweighted Background noise pressure level after measurement Of audible sound level of transformer 29.8 4B (A) Corrected A-weighted Average Sound Pressure Level of Transformer 28.5 dB(A) ‘Sound power level 38.8 dB(A) Cutline showing positions of sound level sensors: PaoL. (EU. Prakash) ‘Test Engineer ULR-T¢5452200SCLT0525F SHORT CIRCUIT LABORATORY Sheet 6 of 8 Discipline: Electrical Testing P.8.NO.8086, SADASHIVANAGAR POST OFFICE CENTRAL POWER RESEARCH INSTITUTE Tost Report Numb PRIBLRSCL20T0525 (Member of STL) TEST REPORT Dato: 20 October 2020 3, MEASUREMENT OF ZERO- SEQUENCE IMPEDANCE ON THREE ~ PHASE TRANSFORMERS Phase test current passed (1/3) VValiage measured belween neuitl terminal (2n)& shoring Point of 2u, 2, 20 Zero- sequence impedance (Zs) Test Frequency Conclusion: The sample tested complies with IEC 60076-10: 2016 & Subclause Jerid © SO Test Engineer ULR-TC5452200SCLTO525F Discipline: Electrical Testing Group: Inductors & Transformers SHORT CIRCUIT LABORATORY P.B.NO.8066, SADASHIVANAGAR POST OFFICE SIR C.V. RAMAN ROAD, BENGALURU - 560 080 (INDIA) phone +81 (0) 80- 22072353 Fax: +01 (0) 80- 28801213 4B1.12A 1.641 639% 49.97 Hz the requirement of clause 7.0 of IEC 60076-2:2011, 11.6 of IEC 8076-1 ; 2011 for the tests conducted. Sheet 7 of 8 CENTRAL POWER RESEARCH INSTITUTE (Member of STL) deren K Ree CPRI TEST REPORT CPRIBLRSCL20T0525 Date: 20 October 2020 NOTE 2) The Test results relate only to the sample(s) tested. b) Publication or reproduction of this Test Report in any form other than by complete set of the ‘whole Test Report and in the language writen isnot permitted without the writen consent of CPRI ) Any Corrections / erasure invalidate the Test Report. a 6) NABL has Accredited this laboratory 2s per ISO/IEC 17025: 2017, vide Certificate no, TC-5452 forthe tests carried out e) Any anomaly / discrepancy in the Test Report should be brought to notice of CPRI within 45 days from the date of issue, 1) Alldocuments constituting this Test Report are stitched together with a continuous sik thread the two ends of which have been brought over the front sheet ofthis Test Report and sealed with a CPRI logo printed paper sticker. poeote ob. ARC Prakash) Test Engineer ULR-TC5452200SCLT0525F ‘SHORT CIRCUIT LABORATORY Sheet 8 of 8 loctical Testing _—_PENO.URE,SADASHVANAGAR POST OFFICE Group: Inductors & Transformers SIR C\VRAMAN ROAD. BENGALURU - 560 080 (INDIA) Phone | +91 (0)80- 2207236 Fax: +91 (0) 80- 29601213 CENTRAL POWER RESEARCH INSTITUTE (Member of STL) TEST REPORT Cooling curve of HV winding a aa Resistance Time (minutes) 800 Graph Number: CPRIBLRSCL20T0525G01 Do peeked, (C. L. Prakash) Test Engineer ‘SHORT CIRCUIT LABORATORY. P.B.NO. 8068, SADASHIVANAGAR POST OFFICE SIR CV RAMAN ROAD, BENGALURU- 560 080 (INDIA) Phone ~ 94 (0)80~ 22072962 Fax : 194 (0) 80 29601219, CENTRAL POWER RESEARCH INSTITUTE (Member of STL) TEST REPORT Cooling curve of LV winding 2.08ma | Resistance Time (minutes) Graph Number: CPRIBLRSCL20T0525G02 Bae Jean Test Engineer ‘SHORT GIRGUIT LABORATORY 1B.NO. 8066, SADASHIVANAGAR POST OFFICE SIR CV RAMAN ROAD, BENGALURU. 880 080 (INDIA) Phono $1 (0)80~ 22072385 Fax: +81 (0)80-23601213, - Fonuat ne =820/00/006 LL OWENSONS ARE mm A NETS ARE 9 nromuvon CONTARED THIS DOCUMENT 1 CONRDDITAL AND THE PROPERTY OF SHOI SM ELECTREAS Ls ePmobUCnON oF osm HT FORM S TO GGNE WH TH SPEEFNC PURUSSION Sean wa ae a aan wl 160 [amet at-eam rt i fora ar ay ate €1 mag ser ow Foo top [RHEVERTEGATION OF fe craic 150 ENS pared ao om 3 oe eee ae f__psinaurow teasromer BBG Misnnccss ce LS So naden to sweet Cree saooe] nv mone waren [oer] wa vv mone woo 42] wus io aie) ewan nent BES | Te woe wor 2] er wens ce 9 eos] we tLe] a vawescge = | CEI “FREQUENCY, MASS OF OL ‘3 ([ a0) veeon or ora iss ‘9 Ceo] ol ei on tn penta som YR oF we a a Fort von a 4 93.6 4Nos- BS 1 ‘NOTE 1.¢ WL BE PUNCHED AT THE TIME OF OISPATCH , Z:THOKNESS = Imm. Pe Ta / Test Engineer WEIGHTS ARE SUBJECT TO #10% TOLERANCE. [ei th am ond) cpa) a1 / Bengal av | zone |_OATE WOOTFIGATION ‘Raw | eneeED [APPROVED 7 i = rane | _ ATE e. 7 Shirdi Sai Electricals Ltd. |pescneo_|sexanms {28092020 Zz J |3/82,Industrial Estate,kadapa-516004 [oRawN [Rar {28.02.2020} (atin wep trot = Aidhr'a Pradesh,Indi: jcHecKeD [6.v.RAO [28.09.2020] és faePROvED _[avnasit [26.09 202 SaEeAT re WORK OROER NO : PT-325/10 eS © x MER [owG.No: 4 RP 7039 S6PEOOE en end) asneosswal NoUnaeISTOTED To Ce MOE |S | wm veer [oon | coer [orem ]onne | oo | ooo | ovo: CL ee sel “aN 55] axoammwot | inora | om [own | m [an _[ a PAL val Se] aa ewer Gisinoam [lwo snosNama TIVO —__[etuviinawna] —_() 3O¥IIOA Siro [ a {1881 4AAL ONMNO O3OIANA LON Te SHEITION ¥ SOM OMNIA (erase aaene | ‘ONIHLBYa TWHLNN’ NOL VOION ZHLVHIANAL NO ‘SOITT ONLLSANNOD AT A OIL Wl 91H ROLLOS ¥ OL US: STH ZINE f “SINT NOLLWoISIORES NI HAI RIMES TM SANTWA HN SSAAMON SONVEETIOL Mal O1 L5PENS BAY SLMOIBAA NV SNOISNAWID 2 aT ‘ONRIALOWONVA ONIN AUWVA ATHENS AWM Nouvarsoaas msn 'S31409S300¥ ONY SONILLIS 40 NOMYOGT ONY NO}SSO NOUISOM 3H 1 2. tow asarenan 5 =3I0N ‘n0u0 wo1an l i i vn009 | és i ‘| sevaroas B wz |_vimaaswa l owveNano EN NWSI NAT i * = * . * 7 | SaNOTeNN SIOTENGD LIT OLSOM ONLI] Hi z TESS] SHSTION LM TaNND S5VE| oF] . (ramIENS can TANT WO | 6 STSUSHI AINO SoH : ema onda i {POMENNC Hunt woLWAeSNOo SraMOMERT Lxvrv 0061) “Ai | NOWARIOSAG ons tc ps

You might also like