Series/Type: B84299K0061
The following products presented in this data sheet are being withdrawn.
For further information please contact your nearest EPCOS sales office, which will also support
you in selecting a suitable substitute. The addresses of our worldwide sales network are
presented at www.epcos.com/sales.
2-line filters B84299K0061 … K0067
for installations and systems
× = approval granted
Dimensional drawings
B84299K0061C000, B84299K0062C000 (2 and 4 A)
M4 x 6
30±0.4
45
51
3 x litz wires AWG 18 2 x litz wires
(BU, BK, GNYE) AWG 18 (BU, BK)
7
350±15
300±15
7
Load
Line
Type Length
Marking B84299K0061C000 65 mm
B84299K0062C000 75 mm
SSB2097-8-E
B84299K0063 (6 A)
64±0.4 M4 x 6
46±0.4
67
Line
7
7.5
50
B84299K0064C000 (10 A)
80±0.4 M4 x 8
47±0.4
28
67
8
3 x litz wires AWG 16 2 x litz wires
(BU, BK, GNYE) AWG 16 (BU, BK)
Ground terminal M4 x 8
for shielding braid
or fixing stud
7
350±15
Load
Line
300±15
55
Marking
1
ø10
68.5
100.5
SSB2099-P-E
B84299K0065 (16 A)
107±0.4 M4 x 6
43±0.4
28
68
9
3 x litz wires AWG 14 2 x litz wires
(BU, BK, GNYE) AWG 14 (BU, BK)
Ground terminal M4 x 8
for shielding braid
or fixing stud
7
Load
7
300±15
Line
71
Marking
100
132
SSB2100-W-E
B84299K0066 (25 A)
130±0.4 M5 x 7
73±0.4
28
85
2 x litz wires 8
3 x litz wires AWG 12
(BU, BK, GNYE) AWG 12 (BU, BK)
Ground terminal M4 x 6
for shielding braid
or fixing stud
7
800±20
Load
Marking
15±3
183
SSB2101-5-E
B84299K0067 (36 A)
130±0.4 M5 x 7
73±0.4
28
85
2 x litz wires 8
3 x litz wires AWG 10
(BU, BK, GNYE) AWG 10 (BU, BK)
Ground terminal M4 x 6
for shielding braid
or fixing stud
7
800±15
Load
Marking
15±3
183 SSB2102-D-E
60 60
40 40
20 20
0 0
10 4 10 5 10 6 10 7 Hz 10 8 10 4 10 5 10 6 10 7 Hz 10 8
f f
60 60
40 40
20 20
B84299K0063
0 0
10 4 10 5 10 6 Hz 10 7 10 4 10 5 10 6 Hz 10 7
f f
dB dB
α α
80 80
60 60
40 40
20 20
B84299K0065 B84299K0066
0 0
10 4 10 5
10 6
Hz 10 7
10 4 10 5
10 6 Hz 10 7
f f
Filters for 36 A
SSB0329-H
100
dB
α
80
60
40
20
B84299K0067
0
10 4 10 5 10 6 Hz 10 7
f
Important information
Please read all safety and warning notes carefully before installing the EMC filter and putting it into
operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs
are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the appro
priate safety measures are not carried out or the warnings in the text are not observed.
Warnings
■ It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
■ Danger of electric shock. EMC filters contain components that store an electric charge. Danger
ous voltages can continue to exist at the filter terminals for longer than five minutes even after
the power has been switched off.
■ The protective earth connections shall be the first to be made when the EMC filter is installed and
the last to be disconnected. Depending on the magnitude of the leakage currents, the particular
specifications for making the protective-earth connection must be observed.
■ Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen
cies that may cause resonances etc. can lead to destruction of the filter housing.
■ EMC filters must be protected in the application against impermissible exceeding of the rated
currents by suitable overcurrent protective.
11 01/06
EMC filters
Important notes
12 01/06