You are on page 1of 10

See discussions, stats, and author profiles for this publication at: https://www.researchgate.

net/publication/306421722

Assessing hydraulic conditions through Francis turbines using an


autonomous sensor device

Article in Renewable Energy · December 2016


DOI: 10.1016/j.renene.2016.08.029

CITATIONS READS

60 6,380

7 authors, including:

Tao Fu Zhiqun Daniel Deng


Battelle Memorial Institute Pacific Northwest National Laboratory
53 PUBLICATIONS 705 CITATIONS 229 PUBLICATIONS 6,018 CITATIONS

SEE PROFILE SEE PROFILE

Joanne Duncan Daqing Zhou


Pacific Northwest National Laboratory Hohai University
25 PUBLICATIONS 308 CITATIONS 70 PUBLICATIONS 1,004 CITATIONS

SEE PROFILE SEE PROFILE

Some of the authors of this publication are also working on these related projects:

Deep Learning for Automating ID of Eels in Multibeam Sonar Data View project

Columbia River Fish Passage at Hydroelectric Facilities View project

All content following this page was uploaded by Tao Fu on 06 September 2016.

The user has requested enhancement of the downloaded file.


Renewable Energy 99 (2016) 1244e1252

Contents lists available at ScienceDirect

Renewable Energy
journal homepage: www.elsevier.com/locate/renene

Assessing hydraulic conditions through Francis turbines using an


autonomous sensor device
Tao Fu, Zhiqun Daniel Deng*, Joanne P. Duncan, Daqing Zhou, Thomas J. Carlson,
Gary E. Johnson, Hongfei Hou
Pacific Northwest National Laboratory, Energy & Environment Directorate, Richland, WA 99352, United States

a r t i c l e i n f o a b s t r a c t

Article history: Fish can be injured or killed during turbine passage. This paper reports the first in-situ evaluation of
Received 6 February 2016 hydraulic conditions that fish experienced during passage through Francis turbines using an autonomous
Accepted 9 August 2016 sensor device at Arrowrock, Cougar, and Detroit Dams. Among different turbine passage regions, most of
the severe events occurred in the stay vane/wicket gate and the runner regions. In the stay vane/wicket
gate region, almost all severe events were collisions. In the runner region, both severe collisions and
Keywords:
severe shear events occurred. At Cougar Dam, at least 50% fewer releases experienced severe collisions in
Francis turbine
the runner region operating at peak efficiency than at the minimum and maximum opening, indicating
Turbine evaluation
Fish-friendly turbine
the wicket gate opening could affect hydraulic conditions in the runner region. A higher percentage of
Turbine passage releases experienced severe events in the runner region when passing through the Francis turbines than
Turbine operations through an advanced hydropower Kaplan turbine (AHT) at Wanapum Dam. The nadir pressures of the
three Francis turbines were more than 50% lower than those of the AHT. The three Francis turbines had
much higher magnitudes and rates of pressure change than the AHT. This study provides critical infor-
mation on hydraulic conditions and fish passage information of Francis turbines, which can help guide
future laboratory studies of fish passing through Francis turbine, design fish-friendly turbines, and
optimize the operation of existing turbines for better fish passage conditions.
© 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND
license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

1. Introduction up to several hundred meters depending on hydraulic turbine type.


Fish can often pass through a turbine runner in less than a second.
Hydropower is an important renewable energy source [1]. The absolute pressure on the downstream side of the turbine blade
However, hydropower projects can also pose negative environ- can be less than the atmospheric pressure. The consequence of fish
mental impacts because downstream migrating fish can be injured being exposed to this rapid and sometimes extreme pressure
or killed when they pass through turbine passages due to the severe change has been studied extensively and categorized as baro-
hydraulic conditions. It is critical to understand the hydraulic trauma injury [3e8]. Early studies [4,9e12] found that pyhsosto-
conditions and physical stresses to which fish are exposed when mous fish, which have swim bladders, can endure high magnitudes
they pass through hydraulic turbines so that fish friendly turbines of pressure without being injured or killed because of their ability
can be designed and turbine operations can be guided to mitigate to adjust their swim bladder by ingesting or venting gas through
the impacts [2]. the mouth and pneumatic duct. However, the decompression
Injuries and mortalities of turbine-passed fish can result from process that occurs when fish pass through turbine runners can
several mechanisms [2]: rapid and extreme pressure changes, cause fish mortality (i.e., barotrauma). These studies have found
cavitation, shear stress, turbulence, strike, and grinding. Rapid that barotrauma injuries can be related to the ratio of exposure
pressure change happens when fish pass through a turbine runner. pressure to acclimation pressure (Pe/Pa). Fish mortalities were
The absolute pressure head upstream of a turbine blade can be to observed mostly when Pe/Pa was less than 0.4 and little or no
mortality was observed when Pe/Pa was larger than 0.6. Abernethy
and Becker [13] used a series of pressure testing devices to expose
several fish species (Bluejill, Fall chinook salmon, and rainbow
* Corresponding author.
trout) to realistic pressure-time profiles associated with turbine
E-mail address: Zhiqun.deng@pnnl.gov (Z.D. Deng).

http://dx.doi.org/10.1016/j.renene.2016.08.029
0960-1481/© 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
T. Fu et al. / Renewable Energy 99 (2016) 1244e1252 1245

passage; they found different mortality rates when fish were and the diameter was 800 mm. The rotational speed was 250 rpm.
acclimated to different depths and exposed to different total dis- At HEP2, one Kaplan turbine was installed. The runner had four
solved gas levels and nadir pressures. Recently, Brown et al. [8] blades and the diameter was 2100 mm with a rotational speed of
conducted extensive experiments using an advanced turbine 333 rpm. Their study found the mortality rates of the smolts
pressure simulation system [14] and identified that the ratio of fish passing through the Francis turbines were consistently higher than
acclimation depth to nadir pressure was the most predictive vari- those of the fish passing through the Kaplan turbine: 38% vs. 9% in
able for estimating the probability of mortal injury of juvenile 2004 and 33% vs. 13% in 2005.
Chinook salmon. Cavitation happens when water pressure is at or Although fish injury mechanisms during turbine passages were
below vapor pressure and gas bubbles form in the water [10,15]. studied extensively, the leading mechanism/mechanisms that
Studies have suggested that the collapse of gas bubbles can create cause fish injuries can vary at different dams due to different tur-
violent shock waves and nearby fish could get injured [10,12]. Shear bine passage configurations. While the live fish field studies pro-
stress happens when forces are applied parallel to the fish body. vided the overall turbine biological performance, they do not
Laboratory studies have shown that shear flow can cause different provide enough information to understand what hydraulic condi-
fish injuries [16,17]. Shear stress can be near the stay vanes, wicket tions and physical stresses caused the mortality and injury, espe-
gates, runner and draft tube [18]. Different scales of turbulence cially where mortality and injury occurred. To better understand
occur throughout a turbine passage. Small-scale turbulence, such as these questions, an autonomous sensor device (Sensor Fish) was
local eddies, may distort and compress part of the fish body and developed [30,31]. Sensor Fish can be released into operating tur-
cause localized fish injuries. Large-scale turbulence, such as bines independently or concurrently with live fish to measure in-
vortices in the draft tube (swirl), can disorient fish and make them situ hydraulic conditions. Sensor Fish measurements can help re-
to be more susceptible to predators in the tailrace [2]. Strike hap- searchers understand the fish injury mechanisms in each passage
pens when fish collide with turbine passage structures such as stay region, guide future laboratory studies of fish passing through
vanes, wicket gates, turbine runner hub/blades, and draft tube Francis turbine, design fish-friendly turbines, and optimize the
walls. Several blade-strike models were developed to predict fish operation of existing turbines for better fish passage conditions.
mortality due to turbine runner blades [10,19e23]. Grinding hap- This study evaluated the hydraulic conditions within Francis tur-
pens when fish squeeze through narrow opening of clearances bines using Sensor Fish at three different dams: Arrowrock Dam,
between structures in a turbine passage [2]. Fish grinding injuries Cougar Dam, and Detroit Dam. Severe hydraulic conditions
are usually localized bruises, but they can also be deep cuts or even including collision and shear events in each region of a turbine
decapitation. passage were quantified. Nadir pressure, pressure change, and the
Francis turbines and Kaplan turbines are the two most common rate of pressure change in the turbine runner region were also
turbine types. Francis turbines are usually installed in storage estimated. The results were then compared with the Sensor Fish
projects with a normal head range of 30e550 m, while Kaplan results from the AHT Kaplan turbine at the Wanapum Dam and the
turbines are usually installed on run-of-river projects and head concurrent live fish results.
ranges from 1.5 to 80 m [24]. Francis turbines usually have more
runner blades (9e25) than Kaplan turbines (3e8). The flow in the 2. Methods
runner region is also different: water enters Francis turbine runners
in the radial direction and exits in axial directions; water enters and 2.1. Test sites
exits the Kaplan turbines in the axial direction at both inlet and
outlet at the turbine runner. The engineering difference between Arrowrock Dam is located on the Boise River approximately
these two turbine types could lead to different physical conditions 35.4 km upstream from Boise, Idaho. It is a 108 m tall concrete
for passing fish. Mortality rates of fish passing through Francis thick-arch dam consisting of 10 clamshell valve conduits and a
turbines are quite variable and frequently greater than those of fish power plant with two Francis turbine units. Each turbine has 24
passing through Kaplan turbines [25]. Kaplan turbines with an wicket gates and the capacity is 7.5 MW. The turbine runner is
adjustable blade propeller can have a fish survival rate from 85 to 1.72 m in diameter with 13 blades. The penstock of each turbine
96% [26]. For Francis turbines, Eicher [27] reviewed 22 previous unit ties into one of the clamshell valve conduits.
studies and found the reported fish mortality ranging from 5% to Cougar Dam is a 138 m tall rock fill dam located on the South
50%. Eicher's review also found a significant relationship between Fork of the McKenzie River in Oregon. It consists of two regulating
peripheral runner velocity and mortality of salmonids for Francis outlets and one powerhouse with two Francis turbine units. The
turbines and higher peripheral runner velocity would lead to capacity of each turbine unit is 12.5 MW. Each unit has 24 wicket
higher mortality. Recent field studies showed the mortality could gates and the turbine diameter is 1.83 m with 13 blades.
be relatively high when fish pass Francis turbines. For example, a 2- Detroit Dam is located at river 78.9 km on the North Santiam
year study by Serrano et al. [28] used both acoustic and radio River in Oregon. It is a concrete dam with a 6-bay spillway, two
telemetry to track Atlantic salmon smolts at Testebo River, Sweden. regulating outlets and one powerhouse with two Francis turbine
They released 24 and 34 radioetagged fish with mean body length units. Each turbine unit has 24 wicket gates and the capacity is
of 223 mm and 214 mm in 2006 and 2007, respectively. The fish 50 MW. Each turbine runner is 3.30 m in diameter with 13 blades.
were released approximately 3.1 km upstream of the power station,
which contains two Francis turbine units with a discharge capacity 2.2. Sensor Fish
of 10 m3/s. The study found five fish in 2006 and 12 fish in 2007
entered into turbine units and the turbine mortality was 60% and The Sensor Fish (Fig. 1) is an autonomous sensor package to
75% for the two years, respectively. Calles et al. [29] studied the study the physical conditions of hydraulic turbine, spillway and
migrating behavior of brown trout in Eman River, Sweden in 2004 other hydraulic structure passages [30]. It is 24.5 mm in diameter
and 2005 using Passive Integrated Transponder and radio telem- and 90.0 mm in length. The weight of the Sensor Fish is 43 g and it
etry. Downstream migrating smolts were observed at two low head is neutrally buoyant in fresh water. At the sampling rate of 2000 Hz,
power plants (8.7 m head at HEP2 and 5.5 m head at HEP3). HEP3 the Sensor Fish measures linear accelerations and angular velocities
was located 800 m upstream of HEP2 with two twin-Francis tur- in three dimensions, pressure, and temperature. Before the
bine units and four runners installed. Each runner had 16 blades deployment, each Sensor Fish device was calibrated and evaluated
1246 T. Fu et al. / Renewable Energy 99 (2016) 1244e1252

0.0075 s and a shear event has peak duration longer than 0.0075 s,
where peak duration of acceleration is defined as the duration
within 70% of the peak value of a high amplitude impulse
acceleration.
Similar to Kaplan turbines, the largest pressure rate of change
also occurs when fish passes through the Francis turbine runner to
reach the underside (or suction side) of the turbine blades. Median
nadir pressure, average magnitude of pressure change and pressure
rate of change between entering the runner region and the nadir
pressure point were computed for each treatment. The results were
then compared to similar measurements reported for an advanced
hydropower Kaplan turbine (AHT) at Wanapum Dam that included
features to improve survival for fish passage [32]. Although the flow
and power generation of the AHT differ from those of the Francis
turbines, a qualitative comparison of the Sensor Fish data high-
lights areas for fish passage improvements.

3. Results and discussion


Fig. 1. Sensor Fish device. Drawing shows the measurement axes for the three com-
ponents of linear acceleration (up-down, forward-back, and side to side) and three 3.1. Francis turbine passage examples
components of angular velocities (pitch, roll, and yaw).

Fig. 2 shows a typical example of the pressure and acceleration


measurements at Arrowrock Dam. Fig. 2 (a) and (c) were from
individually.
Sensor Fish F908 and Fig. 2 (b) and (d) were from Sensor Fish F664.
The top two panels (a) and (b) showed the overall measurements
2.3. Study design from the Sensor Fish release to the turbine draft tube exit. The
bottom two panels (c) and (d) showed the detailed Sensor Fish
At Arrowrock Dam, turbine Unit 1 was chosen for the Sensor measurements in the stay vane/wicket gate region and the turbine
Fish study. The turbine discharge during the study was 22.65 m3/s runner region. In (a) and (b), Tr is the time when the Sensor Fish
and the wicket gate opening was at 80%. Eleven Sensor Fish were entered the forebay; T1 is the time when the Sensor Fish left the
released in the dam forebay before the clamshell value conduit clamshell value conduit entering the turbine penstock; T5 is the
entrance. Five valid datasets were collected. time when the Sensor Fish reached tailrace water surface. In (c) and
At Cougar Dam, three treatments were evaluated at turbine Unit (d), T2 is the time when the Sensor Fish entered into the stay vane
2 for different turbine operation conditions: minimum wicket gate from scroll case; T3 is the time when the Sensor Fish entered the
opening, maximum wicket gate opening, and peak efficiency turbine runner from wicket gate exit; T4 is the time when the
operation. The corresponding turbine discharges were 9.63, 15.57, Sensor Fish left the turbine runner entering the turbine draft tube.
and 12.88 m3/s, respectively. The Sensor fish were released at the In the penstock region, both Sensor Fish experienced one severe
penstock entrance in the dam forebay. Sixteen Sensor Fish were event (IC_1) and no shear events were observed. In the stay vane/
released at the minimum wicket gate opening condition and four wicket gate region, both Sensor Fish had one slight shear event
valid datasets were acquired. Fourteen Sensor Fish were released at right after entering the stay vane (WS_1) and one slight shear event
the maximum wicket gate opening condition and three valid right before exiting the wicket gate (WS_2). In the runner region,
datasets were collected. Four Sensor Fish were released at the peak both Sensor Fish experienced one median shear event (RS_1) when
efficiency condition and all of them were successfully recovered they left the turbine runner entering the draft tube region, which
with valid data. was right before they reached the nadir pressure (Pnadir). Sensor
At Detroit Dam, 23 Sensor Fish were released through turbine Fish F908 passed both the stay vane/wicket gate region and runner
Unit 2 in the dam forebay before the turbine penstock entrance. region without experiencing any severe events, while Sensor Fish
Nineteen of them were successfully recovered with valid data. F664 had one severe collision (WC_1) with the wicket gate and one
During the test, the turbine discharge was 62.30 m3/s. severe collision (RC_1) with the turbine runner. In the draft tube
region, no median event or severe event was observed from either
2.4. Data analysis Sensor Fish.

Pressure measurements were used to estimate the location and 3.2. Exposure events that Sensor Fish experienced during Francis
passage time of the Sensor Fish, including the injection pipe, the turbine studies
turbine penstock region, the stay vane/wicket gate region, the
turbine runner region, and the draft tube region. Accelerations In the penstock region, no Sensor Fish experienced severe shear
were used to identify Sensor Fish events. When a Sensor Fish has events at any of the three Francis turbines (Table 2). Of the 19
direct contact with passage structures or passes through turbulent Sensor Fish releases at Detroit Dam, three of them experienced
shear flows, high amplitude impulse accelerations and rotational severe collisions. At Arrowrock Dam, four of the five Sensor Fish
velocities can be recorded. Based on previous laboratory studies releases experienced severe collisions. In all three treatments at
[17] and [30], Sensor Fish events are categorized into three levels of Cougar Dam, no Sensor Fish experience any sever events.
exposure events using the acceleration magnitude (jaj): (1) severe In the stay vane/wicket gate region, more Sensor Fish experi-
event if jaj >¼ 95 g, (2) medium event if 95 g > jaj >¼ 50 g, and (3) enced severe collisions than severe shear events at all sites
slight event if 50 g > jaj >¼ 25 g. Each event can also be identified as (Table 2). At Arrowrock Dam, four of the five releases experienced
a collision event or a shear event based on the acceleration time severe collisions, while only one Sensor Fish experienced severe
duration. A collision event has acceleration peak duration less than shear events. At Detroit Dam, six of 19 releases experienced severe
T. Fu et al. / Renewable Energy 99 (2016) 1244e1252 1247

Fig. 2. Pressure profiles and acceleration profiles collected from two Sensor Fish releases at Arrowrock Dam. The left two panels (a) and (c) were from Sensor Fish F908 and the right
two panels (b) and (d) were from Sensor Fish F664. The top two panels showed the overall profiles from the Sensor Fish release to the tailrace. The lower two panels were the
profiles in the stay vane/wicket gate region and the turbine runner region.

collisions and only one Sensor Fish experienced severe shear


events. For all three treatments at Cougar Dam, one Sensor Fish
experienced severe collisions in each treatment and no Sensor Fish
experienced severe shear events.
In the runner region, except for two Sensor Fish at Arrowrock
Dam, all Sensor Fish experienced either severe collisions or severe
shear events or both. In Detroit Dam study, all 19 Sensor Fish
experienced severe shear events and eight of them experienced
severe collisions. At Arrowrock Dam, three Sensor Fish experienced
severe collisions and one of them experienced severe shear events.
For the three treatments at Cougar Dam, all Sensor Fish experi-
enced severe shear events. One Sensor Fish experienced severe
collisions under the peak efficiency condition, while three Sensor
Fish experienced severe collisions under the minimum opening
condition and the maximum opening condition.
In the draft tube region, two Sensor Fish experienced severe
collisions and one of them had severe shear events at Detroit Dam.
Only one Sensor Fish experienced severe event at Cougar Dam and Fig. 3. Velocity triangles of Francis Turbines at turbine runner blade inlet and outlet
under different operation conditions: (a) maximum wicket gate opening condition; (b)
it was a collision under the minimum opening condition. There was peak efficiency condition; (c) minimum wicket gate opening condition.
no severe event at Arrowrock Dam.
At Cougar Dam, fewer Sensor Fish experienced severe collisions
in the runner region under the peak efficiency condition (1 Sensor efficiency condition; and (c) minimum wicket gate opening con-
Fish) than under the minimum opening condition and the dition. In the velocity triangles at turbine inlet, V1 is the absolute
maximum opening condition (3 Sensor Fish under each condition), flow velocity entering the turbine runner. V1 has two components:
indicating better flow condition in the turbine runner region under U1 and Vr1, where U1 is the peripheral velocity at blade entrance,
the peak efficiency condition compared to the other two condi- and Vr1 is the relative velocity with respect to the runner blade.
tions. Fig. 3 shows the velocity triangles of Francis turbines at the Under both the maximum opening condition (Fig. 3a) and the
turbine runner inlet and outlet under different operation condi- minimum opening condition (Fig. 3c), the direction of Vr1 is not
tions: (a) maximum wicket gate opening condition; (b) peak tangential to the runner blade and consists two components: Vb
1248 T. Fu et al. / Renewable Energy 99 (2016) 1244e1252

and Vw1, where Vb is in the tangential direction to the runner blade are very close (1.71 m vs. 1.83 m); they have the same number of
tip and Vw1 is the same direction as the peripheral velocity of the wicket gates (24); and the wicket gate heights B1 are close too
turbine blade. The existing of extra peripheral velocity component (0.39 m and 0.41 m). Another possible factor might be the flow
(Vw1 in Fig. 3c) and the less peripheral velocity component (Vw1 in velocity entering the wicket gate gaps. The discharge was almost
Fig 3a) could cause swirls or flow separations and result in turbu- twice at Arrowrock Dam than at Cougar Dam peak efficiency con-
lent flows at turbine runner inlet. While under the peak efficiency dition (22.65 m3/s vs. 12.88 m3/s). When water was distributed
condition (Fig. 3b), Vr1 is designed to be in the tangential direction uniformly along the outer circumference of the stay vane ring by
to the runner blade tip [24], which creates a shock-free entry to the the spiral casing, the flow velocity entering stay vane gaps and
runner blade and provides the smoothest possible path for flow to wicket gate gaps was much higher at Arrowrock Dam than at
pass the blade. In the velocity triangles at turbine runner outlet, V2 Cougar Dam because of their similar wicket gate geometry.
is the absolute flow velocity and has two component: U2 is the
peripheral velocity at runner outlet, and Vr2 is the relative velocity 3.3. Comparison of Francis turbine severe events with AHT Kaplan
with respect to the runner blade. Under the peak efficiency con- turbine severe events
dition (Fig. 3b), the flow direction of V2 is designed to close to axial
direction and only has axial component Vf2. Off the peak efficiency The Sensor Fish experienced higher percentage of severe events
condition (Fig. 3a and c), V2 has one extra component Vw2 besides at the three Francis turbines than the AHT Kaplan turbine (Table 3).
Vf2. The existing of Vw2 could cause swirls when flow entering the Of the 536 releases in the AHT Kaplan turbine study [32], 21%
draft tube [33,34], which may also result in turbulent flows in the experienced severe collisions and 1% experienced severe shear
turbine blade outlet. When Sensor Fish passed the turbine runner events. For the three Francis turbines, all Sensor Fish releases
under either the maximum opening condition or the minimum experienced either severe collisions (Arrowrock Dam), or severe
opening condition, they may have higher probability of colliding shear events (Detroit Dam, minimum opening condition and peak
with runner blades due to the more turbulent flows than under the efficiency condition at Cougar Dam), or both (maximum opening
peak efficiency condition. In order to make runner passage more condition at Cougar Dam). In the runner region, fewer Sensor Fish
fish friendly for existing turbines, turbine units could be operated at experienced severe shear events than severe collisions in the AHT
or around peak efficiency conditions, which can be achieved by Kaplan turbine study (1% vs. 5%). However, all Sensor Fish (100%)
distributing power load among several turbine units and avoiding experienced severe shear events at Detroit Dam and Cougar Dam.
operating one unit at the maximum wicket gate condition. For In the wicket gate region, more Sensor Fish experienced severe
newly designed turbines, variable speed approach could be collisions than severe shear events in the AHT Kaplan turbine study
explored. Early study by Frank et al. [26] have showed that the (14% vs. 1%), which was also observed in all Francis Turbine studies
combination of variable turbine speed with adjustable wicket gate (80% vs. 20% at Arrowrock Dam, 32% vs. 5% at Detroit Dam, 25% vs.
openings could enable turbine units to operate at peak efficiency 0% under minimum opening condition at Cougar Dam, 33% vs. 0%
conditions at various heads. In addition, a recent simulation of a under the maximum opening condition at Cougar Dam, and 25% vs.
2  320 MW variable speed pump-turbine power plant presented a 0% under the peak efficiency condition at Cougar Dam).
feasible control strategy that can provide high dynamic perfor- The three Francis turbines had higher percentage of severe
mance in full compatibility with safety requirements [41]. events, especially severe shear events, in the runner region than the
The Sensor Fish experienced more severe collisions than severe AHT Kaplan turbine (Table 3), suggesting that the flow might be
shear events in the stay vane/wicket gate region at the three France more turbulent in the Francis turbines than in the AHT Kaplan
turbines: 4 severe collisions vs. 1 severe shear events at Arrowrock turbine. Francis turbines and Kaplan turbines have different flow
Dam, 6 severe collisions vs. 1 severe shear events at Detroit Dam, patterns in the runner region. In Kaplan turbines, water enters and
and 1 severe collisions vs. 0 severe shear events under all three exits the runner region in axial direction with little radial move-
operation conditions at Cougar Dam, suggesting that fish mortality ment. In Francis turbines, flow enters the runner bucket in the
could be more due to collisions than shear events in the stay vane/ radial direction and exit in axial direction. Having both axial flow
wicket gate region. Researchers have found that fish mortality in and radial flow in each runner bucket, flow condition in Francis
the wicket gate region is related to the wicket gate clearance and turbines could be more turbulent than in Kaplan turbines. The
the narrow clearance between wicket gates can increase the fish geometry difference between the three Francis turbines and the
mortality [25,27]. However, the wicket gate clearance alone could AHT Kaplan turbine might also contribute to the higher percentage
not explain why Sensor Fish experienced more severe collisions at of Sensor Fish experienced severe collisions when passing three
Arrowrock Dam than at Cougar Dam because the two dams have Francis turbine runners than the AHT Kaplan turbine runner. The
similar wicket gate geometry (Table 1): their runner diameters D1 three Francis turbines all have much smaller runner diameter D1

Table 1
Physical parameters of the three Francis turbines.

Arrowrock Dam Detroit Dam Cougar Dam

Min opening Max opening Peak efficiency

Head (m) 56.08 94.49 88.09 88.09 88.09


Rotational speed (rpm) 300 163.6 400 400 400
Penstock diameter (m) 1.47 3.86 3.20 3.20 3.20
Runner diameter D1 (m) 1.71 3.30 1.83 1.83 1.83
Wicket gate height B1 (m) 0.39 0.54 0.41 0.41 0.41
Runner exit diameter D2 (m) 1.81 3.90 1.95 1.95 1.95
Runner peripheral velocity (m/s) 26.81 28.29 38.30 38.30 38.30
Number of runner blades 13 13 13 13 13
Number of wicket gates 24 24 24 24 24
Unit discharge (m3/s) 22.65 62.30 9.63 15.57 12.88
Penstock average velocity (m/s) 13.29 5.32 2.39 3.87 3.20
T. Fu et al. / Renewable Energy 99 (2016) 1244e1252 1249

Table 2
Number of Sensor Fish that experienced severe events in each passage region.

Passage region Severe event type Arrowrock Dam Detroit Dam Cougar Dam

Minimum opening Maximum opening Peak efficiency

Valid releases (N) 5 19 4 3 4


Penstock Collision 4 3 0 0 0
Shear 0 0 0 0 0
Stay vane/wicket gate Collision 4 6 1 1 1
Shear 1 1 0 0 0
Turbine runner Collision 3 8 3 3 1
Shear 1 19 4 3 4
Draft tube Collision 0 2 1 0 0
Shear 0 1 0 0 0
All regions Collision 5 16 3 3 2
Shear 2 19 4 3 4

Table 3
Percentage of the Sensor Fish that experienced severe collisions and severe shear events. The Sensor Fish data at Wanapum Dam are from Deng et al. ([31]).

Passage region Severe event type Arrowrock Dam (%) Detroit Dam (%) Cougar Dam Wanapum Dam (%)

Minimum opening (%) Maximum opening (%) Peak efficiency (%)

Penstock Collision 80 16 0 0 0 0
Shear 0 0 0 0 0 0
Stay vane/wicket gate Collision 80 32 25 33 25 14
Shear 20 5 0 0 0 1
Turbine runner Collision 60 42 75 100 25 5
Shear 20 100 100 100 100 1
Draft tube Collision 0 11 25 0 0 3
Shear 0 5 0 0 0 0
All regions Collision 100 84 75 100 50 21
Shear 40 100 100 100 100 1

(1.71 m at Arrowrock Dam, 3.3 m at Detroit Dam, and 1.83 m at


Cougar Dam) (Table 1) than the AHT Kaplan turbine diameter
(7.75 m). The 13 blades in each of three Francis turbines divided the
runner bucket into much smaller space than the six blades in the
AHT Kaplan turbine. The rotational speed of the three Francis tur-
bine runners (300 rpm at Arrowrock Dam, 164 rpm at Detroit Dam,
and 400 rpm at Cougar Dam) were also higher than that of the AHT
Kaplan turbine runner (86 rpm). Therefore, when the Sensor Fish
enter the turbine runner region, they have higher possibility of
colliding with the leading edge of the runner blade in the three
Francis turbine runners than the AHT Kaplan turbine runner.

3.4. Pressure

All measured nadir pressures were below the barometric pres-


sure (101.3 kPa) in the three Francis turbines (Fig. 4). A minimum
median nadir pressure of 24 kPa was observed under the maximum
opening condition at Cougar Dam. Compared with the results of the
AHT Kaplan turbine at Wanapum Dam [32], which had median
nadir pressures above the barometric pressure, the median nadir
pressure of the three Francis turbines were lower than the AHT
Fig. 4. Median and range of the lowest pressure (nadir) that the Sensor Fish experi-
Kaplan turbine. The range of nadir pressure was from 6 kPa to enced in each study. The Sensor Fish data at Wanapum Dam are from Deng et al. ([31]).
71 kPa for the three Francis turbines, while the range was from
42 kPa to 189 kPa for AHT Kaplan turbine. AHT Kaplan turbine has
the trend that nadir pressure decreases when turbine discharge Wanapum Dam (295 kPa) (Table 4). However, the rate of pressure
increases [32]. This trend was not observed from the three different change at Arrowrock Dam (4661 kPa/s) was almost four times the
wicket gate opening treatments at Cougar Dam, where higher nadir maximum rate of pressure change of the AHT Kaplan turbine at
pressures in terms of median, minimum, and maximum were Wanapum Dam (1180 kPa/s). Both the magnitude and the rate of
observed under the peak efficiency condition than the minimum pressure change were also much higher at Detroit Dam and Cougar
opening condition and the maximum opening condition. Dam than the AHT Kaplan turbine. The trend that rate of pressure
The average magnitude of pressure change from the turbine change increases when the discharge increases, which was
wicket gate through the runner exit at Arrowrock Dam (283 kPa) observed in the AHT Kaplan turbine study [32], was also observed
was close to the highest in the AHT Kaplan turbine study at
1250 T. Fu et al. / Renewable Energy 99 (2016) 1244e1252

Table 4
Average magnitude of pressure change, rate of pressure change, and passage time during transit of the sensor from wicket gate passage to exit from the turbine runner in each
study. The Sensor Fish data at Wanapum Dam are from Deng et al. ([31]).

Arrowrock Dam Detroit Dam Cougar Dam Wanapum Dam

Min opening Max opening Peak efficiency 255 m3/s 311 m3/s 425 m3/s 481 m3/s 524 m3/s

Pressure Change (kPa) 283 860 787 848 784 253 254 270 283 295
Pressure ROC (kPa/s) 4661 7670 7769 13,215 9300 490 605 860 1020 1180
Time passing turbine runner (s) 0.090 0.174 0.152 0.085 0.173 0.377 0.407 0.436 0.558 0.289

from the three different wicket gate opening studies at Cougar lowest survival rate of 11.1% (SE ± 6.1%) at Arrowrock Dam and the
Dam: the rate of pressure change was 7769 kPa/s under the mini- highest survival rate of 54.1% (SE ± 3.8%) at Detroit Dam. All Sensor
mum opening condition, 9300 kPa/s under the peak efficiency Fish experienced either severe collisions or severe shear events or
condition, and 13,215 kPa/s under the maximum opening condition both during the turbine passage. Among the three wicket gate
at Cougar Dam. The average time that the Sensor Fish passed the opening conditions at Cougar Dam, lower percentage of Sensor Fish
three Francis turbines was also less than passing the AHT Kaplan experienced severe collisions under the peak efficiency condition
turbine. For the three Francis turbines, the Sensor Fish passed the (50%) than the minimum wicket gate opening condition (75%) and
turbine runner in less than 0.174 s on average; For the AHT Kaplan the maximum wicket gate opening condition (100%). However, the
turbine, the average time ranged from 0.289 s to 0.436 s depending live fish results showed that the 48-h survival rate at peak effi-
on turbine discharge. ciency condition (37.1%) was not higher than at the maximum
Nadir pressure, pressure change and rate of pressure change are opening condition (42.4%) and the 48-h survival rates were not
key parameters to understanding the fish mortal injuries when significantly different between the three conditions [39]. Sensor
they pass through hydraulic turbines. Recent laboratory research by Fish data is in line with the findings of Collins and Ruggles [36],
Brown et al. [8] and [35] identified that the ratio of acclimation who studied several Francis turbines and found that salmonids had
depth to nadir pressure is the most predictive variable for the the maximum survival rate when turbines were operated near peak
probability of mortal injury of juvenile Chinook salmon for Kaplan efficiency. For the live fish studies at Cougar Dam, it is possible that
turbines and the likelihood of mortal injury increased with higher the smaller sample size (40) used in the peak efficiency condition
ratios. The lower nadir pressure ranges that were observed at the was not large enough to show the survival difference than at the
three Francis turbine sites suggested that surface acclimated fish other two test conditions.
could have higher mortality when passing them than passing the Fish size and collisions may have big impact on the higher live
AHT Kaplan turbine at Wanapum Dam. These results also have fish mortality at Arrowrock Dam among the three Francis turbines.
great implications for both turbine operation and fish-friendly Early studies found that fish size was a major factor to fish mortality
turbine design: operating the turbine unit in higher nadir pres- in the Francis turbine units and fish with the larger size are linked
sure condition for existing turbines and designing new turbines to to more mechanical injuries or mortalities [37]. Turnpenny [10] also
have higher nadir pressure can help lower the probability of mortal found that fish mass and fish orientation relative to the blade had
injury due to barotrauma. For example, for juvenile salmons, which important influences on the probability of collisions. Small fish
have median acclamation depth of 6.7 m [42], operating the turbine (<20 g) can be swept around the blade by the water even when
at the peak efficiency condition (median nadir pressure 56 kPa) their center of gravity fell within the direct path of the blade. Large
rather than the maximum operation condition (median nadir fish, on the other hand, tend to follow their original trajectories due
pressure 24 kPa) at Cougar Dam can reduce the probability of fish to their inertia, which increases their probability of collision. The
mortal injury by the factor of 4.2 [35]. For new designed Francis live fish tested at Arrowrock Dam were almost twice in size as those
turbines, if the nadir pressure could be increased from 50 kPa (the at Cougar Dam and Detroit Dam, which could lead to higher
approximately median nadir pressure observed at three study sites) probability of collisions with the turbine runner blades and other
to atmospheric pressure 101.4 kPa, the probability of mortal injury fixed structures. The higher probability of collision could directly
due to barotrauma could be reduced by the factor or 11.1. contribute to the higher live fish mortality rate at Arrowrock Dam.

3.5. Comparison of Sensor Fish results with live fish results 3.6. Sources of error

The correlation between the Sensor Fish data and live fish 48-h Sensor Fish data enabled in-situ evaluations of hydraulic con-
survival rate [38e40] at the three Francis turbines is non- ditions that fish experienced during the passage through Francis
conclusive (Table 5). Among the three turbines, live fish had the turbines at three study sites. Each Sensor Fish measurement

Table 5
Comparison of Sensor Fish that experienced severe events (collision and shear) and live fish survival rates in each study. Live Fish data are from Normandeau et al. [38e40]. At
Cougar Dam, the same pool of fish was used for all three operation conditions.

Arrowrock Dam Detroit Dam Cougar Dam

Min opening Max opening Peak efficiency

Valid Sensor Fish releases 5 19 4 3 4


Sensor Fish with severe collisions (%) 100 84 75 100 50
Sensor Fish with severe shear events (%) 40 100 100 100 100
Fish Species Rainbow trout Rainbow trout Juvenile spring chinook salmon
Number of Released Fish 27 170 169 170 40
Fish length (mm) 200e400 112e246 124e230
48-h Survival (±SE) (%) 11.1 (6.1) 54.1 (3.8) 36.4 (4.0) 42.4 (4.1) 37.1 (8.1)
T. Fu et al. / Renewable Energy 99 (2016) 1244e1252 1251

represented a unique passage path that fish would take during the [2] G.F. Cada, The development of advanced hydroelectric turbines to improve
fish passage survival, Fisheries 26 (2001), 14e13.
turbine passage. However, the number of valid datasets from each
[3] F.K. Cramer, R.C. Oligher, Passing fish through hydraulic turbines, Trans. Am.
study was limited, which prevented researchers from doing more Fish. Soc. 93 (1964) 243e259.
statistical analysis and inferences. The limited sample size was due [4] V.I. Tsvetkov, D.S. Pavlov, V.K. Nezdoliy, Changes in hydrostatic pressure lethal
to two factors: 1) not enough Sensor Fish were released; and 2) to the young of some freshwater fish, J. Ichthyol. 12 (1972) 307e318.
[5] D.L. Beyer, B.G. D'Aoust, L.S. Smith, Decompression-induced bubble formation
some Sensor Fish were damaged or not recovered. However, this in salmonids: comparison to gas bubble disease, Undersea Biomed. Res. 3 (4)
study can help plan future Sensor Fish studies on sample size re- (1976) 321e338.
quirements. For example, if studies would be done when turbine [6] J.L. Rummer, W.A. Bennett, Physiological effects of swim bladder over-
expansion and catastrophic decompression on red snapper, Trans. Am. Fish.
units were operated off the peak efficiency conditions, more sam- Soc. 134 (2005) 1457e1470.
ples might be needed taking into the consideration of possibilities [7] R.S. Brown, T.J. Carlson, A.E. Welch, J.R. Stephenson, C.S. Abernethy,
of Sensor Fish damage and not being recovered. B.D. Ebberts, et al., Assessment of barotrauma from rapid decompression of
depth-acclimated juvenile Chinook salmon bearing radiotelemetry trans-
mitters, Trans. Am. Fish. Soc. 138 (2009) 1285e1301.
4. Conclusions [8] R.S. Brown, B.D. Pflugrath, A.H. Colotelo, C.J. Brauner, T.J. Carlson, Z.D. Deng,
A.G. Seaburg, Pathways of barotrauma in juvenile salmonids exposed to
simulated hydroturbine passage: Boyle's law vs. Henry's law, Fish. Res. 121
Sensor Fish were used to evaluate in-situ hydraulic conditions (2012) 43e50.
that fish experienced when passing through three Francis turbines. [9] M.G. Feathers, A.E. Knable, Effects of depressurization upon largemouty bass,
North Am. J. Fish. Manag. 3 (1983) 86e90.
In all three studies, Sensor Fish experienced more severe collisions
[10] A.W.H. Turnpenny, M.H. Davis, J.M. Fleming, J.K. Davies. Experimental Studies
than severe shear events in the stay vane/wicket gate region, which Relating to the Passage of Fish and Shrimps through Tidal Power Turbines.
is consistent to the observation of the AHT Kaplan turbine at Marine and Freshwater Biology Unit, National Power, Fawley, Southhampton,
Hampshire, England.
Wanapum Dam. The comparison with the AHT was intended as a
[11] J. Hogan, The effects of high vacuum on fish, Trans. Am. Fish. Soc. 70 (1941)
reference instead of a direct comparison between Francis and 469e474.
Kaplan turbines because the flow and power generation of the AHT [12] J.F. Muir, Passage of young fish through turbines, J. Power Div. Proc. Am. Soc.
are not comparable to those of the three Francis turbines. In the Civ. Eng. 85 (1959) 23e46.
[13] J.M. Becker, C.S. Abernethy, D.D. Dauble, Identifying the effects on fish of
turbine runner region, all Sensor Fish at Detroit Dam and Cougar changes in water pressure during turbine passage, Hydro Rev. 22 (5) (2003)
Dam experienced severe shear events while only 1% of the Sensor 32e42.
Fish experienced severe shear events in the AHT Kaplan turbine, [14] J.R. Stephenson, A.J. Gingerich, R.S. Brown, B.D. Pflugrath, Z. Deng, T.J. Carlson,
et al., Assessing decompression in fishes using a mobile aquatic barotrauma
suggesting that the flow condition in the runner region could be laboratory: case study examining the incidence of barotrauma in neutrally
more turbulent in the Francis turbines than in the AHT Kaplan and negatively buoyant juvenile salmonids exposed to simulated hydro-
turbine. Among the three turbine operating conditions at Cougar turbine passage, Fish. Res. 106 (2010) 271e278.
[15] P. Kumar, R.P. Saini, Study of cavitation in hydro turbines e a review, Renew.
Dam, fewer Sensor Fish experienced severe collisions under the Sustain. Energy Rev. 14 (2010) 374e383.
peak efficiency condition than under the minimum and maximum [16] D.A. Neitzel, D.D. Double, Survival estimates for juvenile fish subjected to a
opening conditions. The median nadir pressure and the nadir laboratory-generated shear environment, Trans. Am. Fish. Soc. 133 (2004)
447e454.
pressure range were also higher under the peak efficiency condi-
[17] Z. Deng, G.R. Guensch, C.A. McKinstry, R.P. Mueller, D.D. Dauble,
tion than the other two wicket gate opening conditions. These M.C. Richmond, Evaluation of fish-injury mechanisms during exposure to
differences suggested that a better hydraulic conditions can be turbulent shear flow, Can. J. Fish. Sci. Aquat. 62 (2005) 1513e1522.
[18] G. Cada, J. Loar, L. Garrison, R. Fisher Jr., D. Neitzel, Efforts to reduce mortality
achieved when operating the Francis turbine at the optimized
to hydroelectric turbine-passed fish: locating and quantifying damaging shear
wicket gate opening, which can guide the operation to provide the stresses, Environ. Manag. 37 (2006) 898e906.
most possible fish friendly passages for existing turbines. For newly [19] K. Von Raben, Regarding the problem of mutilations of fishes by hydraulic
designed turbines, variable speed turbine could be considered to turbines, Die Wasserwirtsch. 4 (1957) 97e100.
[20] E. Monten, Fish and Turbine: Fish Injuries during Passage through Power
achieve fish friendly passage when technologies are available. In Station Turbines, Vattenfall, Stockholm, Sweden, 1985.
addition, Sensor Fish experienced lower median nadir pressure, [21] D.J. Solomon, Fish Passage through Tidal Energy Barrages, Technical report for
higher magnitude and rate of pressure change when passing the energy technology support unit: Harwell, UK, 1988. ETSU TID4056.
[22] Z. Deng, T.J. Carlson, G.R. Ploskey, M.C. Richmond, D.D. Dauble, Evaluation of
three Francis turbines than the AHT Kaplan turbine at Wanapum blade-strike models for estimating the biological performance of Kaplan
Dam. Although whether these higher rates of the pressure change turbines, Ecol. Model. 208 (2007) 165e176.
would cause higher barotrauma rates has not been evaluated in a [23] J.W. Ferguson, G.R. Ploskey, K. Leonardsson, R.W. Zabel, H. Lundqvist,
Combining turbine blade-strike and life cycle models to assess mitigation
controlled laboratory setting, studies have clearly shown that the strategies for fish passing dams, Can. J. Fish. Aquat. Sci. 65 (2008) 1568e1585.
probability of fish mortal injury could be reduced by increasing [24] K. Subramanya, Hydraulic Machies, Tata McGraw Hill Education Private
nadir pressure, which can be used to help design new turbine units. Limited, 2013.
[25] EPRI, Fish Entrainment and Turbine Mortality Review and Guidelines, EPRI,
1992. TR-101231.
Acknowledgement [26] G.F. Franke, D.R. Webb, R.K. Fisher, D. Mathur, P.N. Hopping, P.A. March, et al.,
Development of Environmentally Advanced Hydroturbine System Concepts,
Report prepared for the Department of Energy under Contract DE-
The field data collection and initial data analysis at Cougar Dam AC07e96ID13382, 1997.
and Detroit Dam was funded by the U.S. Army Corps of Engineers, [27] Eicher Associates, Turbine-related Fish Mortality: Review and Evaluation of
Portland District. The field data collection and initial data analysis Studies, Electric Power Research Institute, Palo Alto, California, 1987. EPRI AP-
5480.
at Arrowrock was funded by the Boise Project Board of Control. The [28] I. Serrano, P. Rivinoja, L. Karlsson, S. Larsson, Riverine an dearly marine sur-
detailed analysis and writing of this article was funded by the U.S. vival of stocked salmon smolts, Salmo salar L., descending the Testebo River,
Department of Energy Wind and Water Power Technologies Office. Sweden, Fish. Manag. Ecol. 16 (2009) 386e394.
[29] O. Calles, L. Greenberg, Connectivity is a two-way street e the need for a
The study was conducted at Pacific Northwest National Laboratory, holistic approach to fish passage problems in regulated rivers, River Res. Appl.
operated by Battelle for the U.S. Department of Energy. 25 (2009) 1268e1286.
[30] Z. Deng, T.J. Carlson, J.P. Duncan, M.C. Richmon, Six-degree-of-freedom Sensor
Fish design and instrumentation, Sensors 7 (2007) 3399e3415.
References [31] Z. Deng, J. Lu, M.J. Myjak, J.J. Martinez, C. Tian, S.J. Morris, et al., Design and
implementation of a new autonomous Sensor Fish to support advanced hy-
[1] S.I. Yannopoulos, G. Lyberatos, N. Theodossious, W. Li, M. Valipour, dropower development, Rev. Sci. Instrum. 85 (2014) 115001.
A. Tamburrino, et al., Evolution of water lifting devices (pumps) over the [32] Z. Deng, T.J. Carlson, J.P. Duncan, M.C. Richmond, D.D. Dauble, Use of an
centuries worldwide, Water 7 (9) (2015) 5031e5060. autonomous sensor to evaluate the biological performance of the advanced
1252 T. Fu et al. / Renewable Energy 99 (2016) 1244e1252

turbine at Wanapum Dam, J. Renew. Sustain. energy 2 (2010) 053104. Project, Boise, Idaho, Report prepared for Boise Project Board of Control, Boise,
[33] F. Avellan, Introduction to cavitation in hydraulic machinery, in: The 6th In- Idaho, Normandeau Associates, Inc., Drumore, Pennsylvania, 2011.
ternational Conference on Hydraulic Machinery and Hydrodynamics, 2004. [39] Normandeau Associates, Inc, Estimates of Direct Survival and Injury of Juve-
Timisoara, Romania, October 11e22. nile Chinook Salmon (Oncorhynchus tshawytscha) Passing a Regulating Outlet
[34] X. Escaler, E. Egusquiza, M. Farhat, F. Avellan, M. Coussirat, Detection of and Turbine at Cougar Dam, Oregon, Report prepared for the U.S. Army Corps
cavitation in hydraulic turbines, Mech. Syst. Signal Process. 20 (2006) of Engineers, Portland District-Willamette Valley Project, Portland, Oregon,
983e1007. Normandeau Associates, Inc., Drumore, Pennsylvania, 2010.
[35] R.S. Brown, A.H.A. Colotelo, B.D. Pflugrath, C.A. Boys, L.J. Baumgartner, Z. Deng, [40] Normandeau Associates, Inc, Estimates of Direct Survival and Injury of Juve-
et al., Understanding barotrauma in fish passing hydro structures: a global nile Rainbow Trout (Oncorhynchus mykiss) Passing Spillway, Turbine, and
strategy for sustainable development of water resources, Fisheries 39 (2014) Regulating Outlet at Detroit Dam, Oregon, Report prepared for the U.S. Army
108e122. Corps of Engineers, Portland District e Willamette Valley Project, Portland,
[36] C.P. Ruggles, N.H. Collins, Fish Mortality as a Function of the Hydraulic Oregon, Normandeau Associates, Inc., Drumore, Pennsylvania, 2011.
Properties of Turbines, Canadian Electrical Association, Montreal, 1981. [41] Y. Pannatier, B. Kawkabani, C. Nicolet, J. Simond, A. Schwery, P. Allenbach,
Report G 144. Investigation of control strategies for variable-speed pump-turbine units by
[37] M.C. Bell, A.C. Delacy, G.J. Paulic, A Compendium on the Success of Passage of using a simplified model of the converters, IEEE Trans. Ind. Electron. 57 (2010)
Small Fish through Turbines, 1967 (Report submitted to the U.S. Army Corps 3039e3049.
of Engineers, Noth Pacific Division, Portland, OR). [42] B.D. Pflugrath, R.S. Brown, Maximum neutral buoyancy depth of juvenile
[38] Normandeau Associates, Inc, Assessment of Direct Survival/injury of Fish Chinook salmon: implications for survival during hydroturbine passage,
Passing through the Arrowrock Dam and Arrowrock Dam Hydroelectric Trans. Am. Fish. Soc. 141 (2012) 520e525.

View publication stats

You might also like