Professional Documents
Culture Documents
www.metrel.si
Metrel d.d.; Ljubljanska c. 77; Sl -1354 Horjul; Slovenia
Electrical Installation Safety
High Voltage Insulation / Continuity / Earth
Appliance / Machine / Switchboard Safety
Power Quality Analysis
LAN Cabling Certification
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Variable transformers /
Equipment for laboratories and Schools
CATALOGUE 2012/13
Measuring and Regulation Equipment Manufacturer Metrel - Measuring and Regulation Equipment Manufacturer
Metrel is an international Group and an Our commitment to quality is recognized services including the testing of compo-
expert in the research, development by our customers and is ensured by con- nents, subassemblies and prototypes of
and production of test and measure- tinuous and extensive research and de- products. This enables Metrel to launch
UK market ment equipment. Metrel brand name is velopment of new, accurate, reliable and safe and reliable new products into the
worldwide recognized and associated safe to use products. market. The laboratory provides testing
with high quality test and measurement
according to the Low Voltage Directive
products.
Test and Measuring Equipment (2006/95/EC) and the EMC Directive
Metrel UK (2004/108/EC). The main standards that
Unit 1, Hopton House, Ripley Drive, Metrel’s instruments provide test and
Normanton, West Yorkshire, WF6 1QT measurement solutions in different Metrel also complies to include IEC/EN
Tel.: +44 (0) 1924 245 000 maintenance areas including the safety 61010 and IEC/EN 61326.
E-mail: info∞metrel.co.uk
testing of electrical installations and ap-
www.metrel.co.uk pliances, power quality analysis, local
area network analysis and the meas- PRODUCTS
urement of indoor environmental con- Metrel is producing test and measure-
ditions. In short, our products help to ment equipment that is covering the fol-
GERMAN market provide information about the safety and
lowing fields:
functionality of different installations and
environments. Through innovative de- • Electrical Installations Safety Testing
sign, electronics and software solutions (IEC/EN 61557, VDE 0413, VDE 0100,
Mess und Prüftechnik we provide accurate, reliable and safe to BS 7671, HD 60364, CEI 64.8, AS/NZS
Metrel GmbH
use products. 3017, AS/NZS3760).
Orchideenstraße 24
• Portable Appliances, Machines and
90542 Eckental
Tel.: +49 (0) 9126 28996-0 The company strives to be the leader Switchgears Safety Testing (IEC/EN
E-mail: metrel∞metrel.de in advanced technological solutions and 60204-1, IEC/EN 61439-1, IEC/EN
therefore invests over 10 % of the yearly 60335-1, VDE 0701-0702).
www.metrel.de turnover into the R&D department. • Measurement and Testing of Cable
ECOLOGY Networks (TIA/EIA-568-B, ISO 11801,
Our wide range of products is backed up EN 50173, EN 50346, IEC/EN 61935).
GLOBAL market with a complete support package includ- Metrel test and measurement equip- • Testing of Power Distribution Sys-
ing repair and calibration, technical sup- ment complies to the RoHS and WEEE tems and Power Quality Analysis
port and customer training programs. A directives. Metrel strives to meet its (EN 50160).
detailed calibration certificate is supplied goals with the most efficient use of re- • Analysis of Indoor Environment
Measuring and Regulation Equipment as standard with all Metrel products. sources and the least possible impact on Quality (DIN 5032, IEC/EN 60584-1,
METREL d.d.
Ljubljanska c. 77
the environment. EN 12599, EN ISO 7726, ISO 11664).
SI-1354 Horjul
SALES NETWORK • Equipment for Laboratories and
Tel: +386 (0)1 7558 200 Schools: Metrel produces a variety
E-mail: metrel∞metrel.si Metrel’s products are sold and serviced of instruments for electrical testing
www.metrel.si in over 80 countries by local agents and laboratories and educational purposes.
distributors. Our associated companies Typical application areas are: electri-
are managed by local people who know cal workshops, testing labs, research,
the special needs of their markets. Sales development and education. The main
engineers and specially trained techni-
products Metrel produces include
cians staff give excellent service to our
customers. demo boards, power supply units, R-
RESEARCH, DEVELOPMENT AND L-C decades.
The GERMAN market is supported by PRODUCTION • Transformers: Metrel produces two
Metrel GmbH based in Eckental (www. kinds of toroidal transformers: variable
The research, development and pro-
metrel.de) and the UK market is support- transformers (according to standard
duction of Metrel’s products are based
ed by Metrel UK based in Normanton EN60989) and power transformers
in Europe (Slovenia) at Metrel d.d. The
(www.metrel.co.uk). Inquiries for other (according to standard EN 61558).
company strives for total quality control.
countries please direct to Metrel d.d.,
the headquarters based in SLOVENIA A dedicated quality assurance depart-
Besides the test and measurement
(www.metrel.si). ment ensures strict adherence to cus- product portfolio offered by Metrel d.d.
tomer specifications. Highly competent Metrel’s daughter company Metrel Me-
R&D engineers provide advanced solu- hanika d.o.o. also provide a variety of
COMMITMENT TO QUALITY tions for our customers. products focusing on metal process-
Metrel’s quality assurance system is ing. Their core business is sheet metal
based on BS EN ISO 9001. Through TEST LABORATORY production, milled / turned production,
permanent training and education of our manufacturing of tools and surface pro-
employees we strive to increase the ef- The highly professional test laboratory tection. For more information please
ficiency and quality of all our processes. based in Metrel d.d. provides internal visit www.metrel-mehanika.si.
2 3
Metrel - Measuring and Regulation Equipment Manufacturer Instruments Designed with Future in Mind
SERVICES Calibration certificate (non accredited). TRAINING CENTER METREL is one of the world leading man- Portable Appliance / Machine / Switch- shooting and fault finding of connections
Accredited calibration certificate can ufacturers and distributor of high quality board Safety / links, troubleshooting in IT networks.
Metrel provides a variety of services re- Metrel d.d. offers to its customers and electrical measurement and test instru- Metrel’s testers can be used in profes-
lating to training, repair and calibration of also be issued if it is required by the cus-
distributors: ments, providing the market with innova- sional PAT testing, general PAT testing, Indoor Environment Quality
test equipment to the highest standards tomer.
• Training on Metrel’s instruments: tive solutions on the following segments: factory / warehouse PAT testing, multi- Metrel’s indoor environmental measur-
in the industry. location PAT testing and after repair ing instruments are used for measure-
the product training can be customized
Electrical Installation Safety safety testing. Metrel’s instruments of- ment, recording and analysis of various
TECHNICAL SUPPORT on the customer’s needs. Metrel can Metrel offers single and multifunctional fer a selection of key features for exam- indoor ambient parameters. The testers
REPAIR offer training on technical standards, electrical installation testers. The instru- ple auto sequencing, automatic testing, integrate a number of innovative solu-
Metrel provides the following support to
measuring and test methods, use and ments are used for initial and periodic test- Pass / Fail evaluation of results, RCD tions and fit the most demanding ap-
Metrel provides fast and efficient repair its customers and distributors:
application of Metrel instruments. ing of domestic and industrial installations, testing, project uploading, bar-coding plications such as testing of indoor air
services either directly at Metrel’s head • On-line technical support: any in- testing of single and multiphase systems system and Pass / Fail barcode label
quarters service centre or through ap- • Complete distributor setup training: quality, factory climatic conditions, light-
quires related to Metrel products can and testing of TT, TN, IT and 115 V systems. printing, flash test, test of both 230 V ap-
proved business partners. when establishing a new distributor, ning conditions; heat, ventilation and air
be sent onto a designated e-mail ad- Metrel meters offer wide selection of func- pliances and 115 V appliances and many conditioning systems testing, indoor or
dress: Metrel can offer a complete “pack- tionalities and measurements (depending more. dry outdoor sound level measurement,
- help∞metrel.si - GLOBAL market; age” on product training, repair and on the model), can be downloadable or non- industrial sound measurement, band-
CALIBRATION calibration training and assign in es- downloadable. All meters comply with the Power Quality Analysis
- info∞metrel.co.uk - UK market; pass and acoustic filter testing, calibra-
The Calibration Laboratory at Metrel DUS tablishing e local calibration and repair European standard IEC/EN 61557. The power quality analysers can be
- metrel∞metrel.de - GERMAN market. tion work, acoustic equipment testing
widely used for general power quality
is able to calibrate electronic measuring • Technical support line: the technical department. High Voltage Diagnostics assessment in distribution and industrial and much more.
instruments and devices in compliance support can be obtained also over the • Training for calibration and repair of Metrel’s high voltage diagnostic equip- low and middle voltage electric systems
with the requirements of the ISO/IEC Metrel products: this is help for Me- ment (5 ... 10 kV) is used for testing (according to EN 50160), capturing and Digital Multimeters / Clamp Meters /
phone: Voltage And Continuity Testers
17025 standard. The laboratory is ac- trel’s existing and new distributors to insulation resistance of rotating machin- recording of power supply events, flicker
+386 (0)1 7558 200 - GLOBAL market; The digital multimeters, clamp meters
credited by Slovenian Accreditation (SA), enable a high standard of local support ery and cables, production line periodic measurement, power factor correction
+44 (0) 1924 245 000 - UK market; testing and maintenance, troubleshoot- measurements, harmonics measure- and voltage continuity testers are used
a member of European Accreditation
+49 (0) 9126 28996-0 - GERMAN market. to customers who purchase a Metrel ing and analysis of all kinds of insulation ments, transients recording and over- for general / basic testing up to high lev-
(EA), signatory of the Multilateral Agree-
• B2B web support: for Metrel partners product. problems. It gives effective readings in voltage protection devices performance el industrial testing, electronic fault find-
ments for the European Co-operation
a B2B zone enables to obtain technical • Bespoke training for larger end us- high noise environments such as high testing, assessment of UPS, consump- ing, field servicing and heavy duty elec-
for Accreditation (EA) and International trical testing. Some of the key features
and marketing information. ers: In case that a larger customer is voltage substations and switchyards. tion profile recording, ect.
Laboratory Accreditation Co-operation Some of key features of Metrel’s instru- (depending on the model) are TRMS
(ILAC) for calibration and testing. • Download centre: enables to down- requesting training, Metrel can organ-
ments (depends on the model) are PI, Lan Cabling Certification testing, high accuracy, temperature
load files with technical product infor- ize the training according to their spe- DD, DAR testing, R(t) graph plotting, Metrel’s LAN testers are designed to be measurement, lead alert, conductance,
The products from the calibration can be mation. Visit www.metrel.si/support/ cific needs. This can be carried out on high 5 mA charging current, selectable used for verification of copper cabling PC communication, autocheck function,
issued with an Inspection report and a download-centre.html. site or at Metrel’s premises. noise rejection filters, etc. networks up to CAT VI / Class E, trouble- recording of data, etc.
4 5
MEASURING INSTRUMENTS AND TESTERS
CATALOGUE 2012/13
6
Electrical Installation Safety Electrical Installation Safety
GOOD TO KNOW GOOD TO KNOW
Find out more about testing safety of With this function all relevant RCD tests IPSC must be higher than current for rated METREL’s hint:
electrical installations can be carried out in one step which is very disconnection time of the over current METREL installation testers have built-in
According to European standards require- simple and time saving feature. disconnection device. The line – neutral tables with fuses and RCDs parameters.
ments electrical installation safety testing (or line - line) impedance should be low When loop test is performed, the meas-
includes a combination of following tests: RCD selection table according to their enough e.g. prospective short circuit cur- ured value is automatically compared
• Insulation resistance, sensitivity: rent high enough that installed protection to the maximum values set out in the
• Continuity of protective conductors AC type A type B type device will disconnect the short circuit standard (EN 61557) and either a PASS
loop within the prescribed time interval. or FAIL symbol will appear on the screen
and equipotential bonding,
Test circuit for insulation resistance measurement U
• RCD testing, U
to inform the user if the result is within
• Line and fault loop impedance, Test circuit for continuity R200 mA measurement U t METREL’s hint: the required limits.
The insulation resistance test is per- t
• Earth resistance testing (two-wire METREL installation testers have built-in
formed with a DC voltage on a dead sys- t
method without probes, three / four- U tables with fuses and RCDs parameters. Earth resistance
tem and the resistance must be above U
wire method with two probes, method No When line test is performed, the meas- Earth resistance testing is used on TN, TT
the minimum limit set out in the appro- U t
with current clamp and two probes, t response ured value is automatically compared and IT systems to ensure that the resist-
priate standards and regulations.
method with two current clamps) Limit values for electrical installations U
t
to the maximum values set out in the ance of the earth electrode is sufficiently
No No
• Specific earth resistance, acc. to IEC 60364-6: Test circuit for continuous resistance measurement
U
response response
standard (EN 61557) and either a PASS low so that, in the case of a fault, a dan-
U t
• Phase sequence, voltage and frequency. t or FAIL symbol will appear on the screen gerous voltage does not appear on any
Ratedt voltage of DC test Insulation t to inform the user if the result is within parts of the installation or on any appli-
RCD testing Line impedance
These tests are performed in order to en-
circuit (V) voltage (V) resistance (MΩ) the required limits. ances which have a connection to earth.
LV secondary switch-
RCD devices are used as protection Line impedance is measured in loop
sure that the requirements are met for the board or LV main 250 ≥0.5 against dangerous fault voltages and fault comprising of mains voltage source
protection of persons, livestock and prop- switshboard Fault loop impedance The measurement conforms to the EN
currents. Various test and measurements and line wiring (between the line and
erty against the risk of electric shock and Less than or equal to Fault loop is a loop comprising mains 61557-6 standard.
≥1.0 are required for verification of RCDs in neutral conductors or between lines on
to ensure that the automatic disconnec-
500 V including LV main 500 source, line wiring and PE return path to the
switchboard RCD protected installations. Measure- a 3-phase system). It is covered by re-
tion of the supply is performed correctly. quirements of the EN 61557-3 standard. mains source. The measurement is cov- Scope of earth resistance test is:
Greater 1.000 ≥1.0 ments are based on the EN 61557-6
ered by requirements of the EN 61557-3 • Earthing of exposed conductive parts
standard.
METREL’s hint: Scope of line impedance test is: standard. assures that the voltage on them stays
Insulation resistance Scope of RCD test is:
EurotestAT and EurotestXA have built-in the • to verify effectiveness of installed over below dangerous level in case of a fault.
The insulation is intended to prevent any • to verify effectiveness and proper op-
“Insulation ALL” function which enables current devices; Scope of loop impedance test is:
contact with live parts and withstanding eration of the RCDs;
performing of 3-port insulation test (L-N, • to verify internal impedance for supply- • to verify effectiveness of installed over In TN installations the earthing is realized
mechanical, chemical, electrical and ther- • to verify disconnection times and trip
L-PE, N-PE or L1-L2, L1-L3, L2-L3) in one ing purpose. current and / or residual current discon- at the source and / or distribution points
mal stresses. Insulation test discloses in- out currents of RCDs;
step. This is a very time saving feature es- nection devices; that’s why the earthing resistances are
sulation faults caused by pollution, mois- • to verify that there are no or limited pre-
pecially if measuring insulation on outlets. The line-neutral short circuit loop consists of: • to verify fault loop impedances, prospec- usually very low (below 1Ω).
ture, deterioration of insulation materials sent fault currents in the installation.
• Power transformer secondary imped- tive fault currents and fault voltage values.
etc. Insulation resistance measurement is
Continuity of protective conductors ance ZT, TT installations have their own main
covered by the IEC / EN 61557-2 standard. and equipotential bonding The following measurements and tests earthing. The resistances are usually
• ZL (phase wiring from source to fault), In TN systems the fault loop ZL-PE consists of:
The purpose of continuity measurement of RCDs can be performed: • ZT (power transformer secondary impedance); higher than in TN systems (from few Ω
• ZN (neutral wiring from source to fault).
The power must be switched off and the is to check the continuity of the protec- • Contact voltage, • ZL (phase wiring from source to fault); up to several hundred Ω). Because of
The line to neutral impedance is the
installation must be disconnected before tive conductors, the main and supple- • Trip-out time, • RPE (PE / PEN wiring from fault to source). this dangerous fault voltages and body
sum of impedances and resistances that
performing this test to ensure that the mentary equipotential bonds. • Trip-out current, currents can occur at relatively low fault
forms the line to neutral loop. In three
test voltage will not be applied to other The test is carried out using a measure- • RCD autotest. The fault loop impedance is the sum of currents. Therefore TT systems usually
phase system there are three line-neu-
equipment electrically connected to the ment instrument capable of generating tral impedances (ZL1-N, ZL2-N, ZL3-N). impedances and resistances that forms have additional RCD protection.
circuit to be tested, particularly devices a no-load voltage of 4 to 24 V (DC or AC) the fault loop.
sensitive to voltage surges. with a minimal current of 200 mA. ZLN = ZL+ ZN+ZTLN The following earth resistance measur-
ZLPE = ZL+ RPE+ZT ing methods are available:
Insulation resistance shall be measured Continuity test is covered by the EN The prospective short circuit current IPSC • Standard 3-wire (4-wire) method for
between: 61557-4 standard.
is defined as: The prospective fault current IPSC is defined as: standard resistance to earth measure-
• Line conductors, ments;
• Line and PE conductors, The measured resistance must be lower
• 3-wire (4-wire) method with one
than a threshold specified by the stand-
• Line and Neutral conductors, clamp, for measuring resistance to
ard applicable to the installation tested,
• Neutral and PE conductors. earth of individual earthing rods;
which is usually 2 Ω. As the resistance
value is low, the resistance of the meas- • Two clamps method for measuring re-
urement leads must be compensated, sistance to earth of individual earthing
particularly if very long leads are used. Circuit for testing RCD rods (recommended in IEC 60364-6 for
urban areas);
METREL’s hint: METREL’s hint: • Specific earth resistance (is carried out
ULN >Ia
IPSC= ____ ULPE >Ia
IPSC= ____
EurotestAT and EurotestXA can perform the METREL installation testers have built-in in order to assure more accurate calcu-
ZLN ZLPE
N – PE loop test between instrument’s N the “RCD AUTO” function which performs lation of earthing systems e.g. for high-
and PE test terminals. This makes testing RCD testing at x1/2, x1 and x5 current mul- voltage distribution columns, large in-
Test circuit for insulation resistance measurement with the plug test cable on outlets possible. tipliers at both 0° and 180° automatically. Circuit for measurement of line impedance Circuit for measurement of fault loop impedance dustrial plants, lightning systems etc.).
Connection diagrams: Recommended earth resistance meas- Overvoltage category • is the installation single- or three-phase; the instrument will display overall PASS /
uring methods: The overvoltage category specifies • is the RCD present in the installation. FAIL decision. All the results can be saved
TN system the highest mains voltage (or lightning To simplify the selection of the appro- to the structured instrument’s memory at
L1 strike, short circuit due to incorrect use, priate test sequence the detailed flow once for further data verification and au-
etc.) that the instrument can withstand chart is supplied with the instrument. tomatic generation of test report with the
L2
without danger for the tester or for the help of the PC SW EuroLink PRO.
L3
object being measured. The standard After choosing the AUTO SEQUENCE®
N
specifies four overvoltage categories. and setting the limits the user just has The revolutionary AUTO SEQUENCE®
to press TEST button and the sequence procedure allows performing testing up
TN PE The overvoltage category affects com-
will automatically perform all predefined to 5 times faster in comparison with con-
Two clamps method (clamps around main N/PE cable). ponent sizing via the air gap. The higher
tests. When the sequence is finished, ventional methods.
the category, the bigger is the distance
Circuits for three-wire mesurement
TT system Circuit for voltage measurements to the power source.
L1 CAT I - electronic devices, signal level.
CAT II - domestic appliances, portable
L2 appliances, single-phase loads, sockets,
L3 (>10 m from CAT III; >20 m from CAT IV).
N
CAT III - three-phase distribution sys-
TT PE tems, lighting systems in large buildings,
Two-wire method (test from the socket between N and PE) distribution panels.
CAT IV - three-phase systems on power
IT system Circuit for voltage measurement, frequency and phase se- stations, electricity meters, outdoor instal-
quence
Circuits for three-wire mesurement L1
lations and supply cable incoming feed.
METREL’s hint:
L2
METREL installation testers have on-
L3
line voltage monitor which in all func-
N
tions displays on one screen voltages
TT PE
between L to PE, L to N and N to PE
Three-wire method (test leads to auxiliary rods in triangle) (single phase system) or L1 to L2, L2 to
L3 and L1 to L3 (3-phase system). This
Lightning conductor feature allows quickly identify incorrect
connections, disconnected wires or in- CAT I CAT II CAT III CAT IV
Circuit for two clamps measurement correct voltages.
PE test terminal AUTO SEQUENCE® Guide through Verification on Low-voltage electrical installations : IEC 60364-6
A very dangerous situation can occur in is a unique patented by Metrel testing pro-
cedure which allows performing of series
case dangerous voltage is applied to the of requested installation tests with a sin-
PE wire or other accessible metal parts. gle press of TEST button. The results of
A common reason for this fault is incor- each test are automatically compared to
rect wiring. Metrel’s instruments are pre-set limits and PASS / FAIL evaluated.
equipped with touchable PE electrode
Two clamps method
(TEST key). When touching TEST key in While ensuring efficient, fast and easy
way of installation safety testing AUTO
all functions that require mains supply SEQUENCE® guarantees absolute safety
Circuit for one clamp measurement Limits:
the user automatically performs test for of operator due to automatic detection of
2 Ω – above ground,
the presence of phase voltage at the PE possible irregular installation conditions.
10 Ω – complete system,
protection terminal.
20 Ω – individual electrode or 8% of spe- Definite number of test sequences is al-
cific earth resistance. ready stored in the instrument. Besides,
user can program and store custom test
Phase sequence, voltage and frequency sequences.
Phase sequence test is used for deter-
mining of line voltages order in 3-phase The user can choose appropriate pre-
programmed AUTO SEQUENCE® pro-
systems. This order defines direction of
cedure according to following criterions:
rotation of motors and generators. • which part of electrical installation will
be tested;
Phase sequence measurement con- • which earthing system is implemented
Circuit for measurement of spesific earth resistance forms to the EN 61557-7 standard. Example for application of PE test terminal (TN, TT or IT);
MI 3108 EurotestPV
Features Description
MI 3105 (EU) MI 3101 MI 3102H CL MI 3102 MI 3100 MI 3125B MI 3125 MI 2086 (EU) MI 2088
Part No.
EurotestXA EurotestAT EurotestXE 2.5kV EurotestXE EurotestEASI EurotestCOMBO EurotestCOMBO Eurotest 61557 Earth Insulation
Features Description
Insulation resistance
Test voltage (VDC) 50 … 1000 50 … 1000 100 … 2500 100 … 1000 100 … 1000 50 … 1000 50 … 1000 50 … 1000 50 … 1000
INSULATION
Autotest insulation L-PE, N-PE, L-N – – – – – – –
Diagnostic test (PI, DAR calculation) – – – –
CONTINUITY AND Contunuity of PE conductors with automatic polarity change, test current
LOW RESISTANCE 200 mA
MEASUREMENT Low resistance measurement (continuous measurement), test current 7 mA –
Line impedance with Ipsc calculation –
LINE / LOOP Loop impedance with Ipsc calculation –
IMPEDANCE RCD Trip Lock loop impedance (R) –
Built-in fuse tables for PASS / FAIL evaluation – –
Contact voltage measurement without RCD tripping –
RCD trip-out time –
RCD TESTING RCD trip-out current with rising test current –
Automatic testing of RCDs –
RCD type (general and selective) A, AC, B A, AC, B A, AC A, AC A, AC A, AC, B A, AC A, AC –
AC voltage measurement
VOLTAGE,
Online voltage monitor – –
FREQUENCY
Frequency measurement –
PHASE SEQUENCE L1 - L2 - L3 –
Earth resistance 3-(4-)wire method – –
EARTH Earth resistance 3-(4-)wire method with additional current clamp – – – – – – Option
MEASUREMENTS Earth resistance measurement with 2 current clamps Option – Option – – – – Option Option
Specific earth resistance Option Option – – – – – (without ρ adapter)
AUTO SEQUENCE Automatic installation safety testing on Switchboards and Circuts – – – – – – –
TRMS leakage / load current – Option Option – – – Option
Illuminance measurement Option – Option Option – – – Option –
OTHER Varistor test – – – – –
MEASUREMENTS Fuse / fault locator Option Option – – – – – Option –
High resolution loop impedance (mΩ) Option Option – – – – – Option –
Insulation Monitoring Devices (IMD) testing (IT systems) – – – – – – –
Nominal frequency range 14 … 500 Hz 14 … 500 Hz 45 … 65 Hz 45 … 65 Hz 45 … 65 Hz 45 … 65 Hz 45 … 65 Hz 45 … 65 Hz 45 … 65 Hz
PASS / FAIL evaluation of test results – –
IT earthing mode systems support – – – – –
OTHER FEATURES
Low voltage supply systems support – – – – –
Touch electrode –
HELP menu –
COMMUNICATION RS232 – –
PORTS USB – – Option Option
Number of memory levels / memory locations 10 / 2000 10 / 2000 3 / 500 3 / 500 – 3 / 1700 – 3 / 3000 2 / 1000
MEMORY
Professional PC SW – –
SOFTWARE
Advanced PC SW Option – Option – Option – –
CAT III / 600 V CAT III / 600 V CAT III / 600 V CAT III / 600 V CAT III / 600 V CAT III / 600 V CAT III / 600 V CAT III / 300 V CAT III / 300 V
Safety category
CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V CAT II / 600 V CAT II / 600 V
Batteries 6 x AA 6 x AA 6 x AA 6 x AA 6 x AA 6 x AA 6 x AA 4xC 4xC
GENERAL DATA
Built-in battery charger – –
Wieght (kg) 1.37 1.32 1.31 1.31 1.31 1.0 1.0 2.1 1.7
Dimensions (mm) 230 x 103 x 115 230 x 103 x 115 230 x 103 x 115 230 x 103 x 115 230 x 103 x 115 140 x 80 x 230 140 x 80 x 230 265 x 110 x 185 265 x 110 x 185
• Insulation resistance with DC voltage; 0.00 Ω … 9.99 Ω 0.01 Ω ±(5 % of reading + 5 digits)
• Continuity of PE conductors with 200 10.0 Ω … 99.9 Ω 0.1 Ω ±(5 % of reading + 5 digits)
Loop impedance (EN 61557-3)
mA test current with polarity change; 100 Ω … 999 Ω 1Ω ±10 % of reading
• Continuity of PE conductors with 7 1.00 kΩ … 9.99 kΩ 10 Ω ±10 % of reading
mA test current (continuous measure- 0.00 Ω … 9.99 Ω 0.01 Ω ±(5 % of reading + 5 digits)
ment) without RCD tripping; 10.0 Ω … 99.9 Ω 0.1 Ω ±(5 % of reading + 5 digits)
Line impedance (EN 61557-3)
100 Ω … 999 Ω 1Ω ±10 % of reading
• Line impedance; 1.00 kΩ … 9.99 kΩ 10 Ω ±10 % of reading
• Loop impedance;
Voltage drop 0.0 % … 99.9 % 0.1 & Consider accuracy of line impedance
• Loop impedance with Trip Lock RCD
Voltage 0 V … 550 V 1V ±(2 % of reading + 2 digits)
function;
• TRMS voltage and frequency; 0.00 Hz … 9.99 Hz 0.01 Hz
Frequency ±(0.2 % of reading + 1 digits)
10.0 Hz … 499.9 Hz 0.1 Hz
• Phase sequence;
• RCD testing (general and selective, Phase sequence (EN 61557-7) 1.2.3 or 3.2.1
type AC, A and B); RCD testing (EN 61557-6) I∆N: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1 A
• Earth resistance (3-wire method). - Contact voltage UC
0.0 V … 19.9 V 0.1 V (-0 % / +15 %) of reading ±10 digits
20.0 V … 99.9 V 0.1 V (-0 % / +15 %) of reading
0 ms … 40.0 ms 0.1 ms ±1 ms
- Trip-out time
0 ms … max. time 0.1 ms ±3 ms
0.2 x I∆N … 1.1 x I∆N (AC type) 0.05 x I∆N ±0.1 x I∆N
0.2 x I∆N … 2.2 x I∆N (A type, I∆N < 30 mA) 0.05 x I∆N ±0.1 x I∆N
- Trip-out current
KEY FEATURES: 0.2 x I∆N … 1.5 x I∆N (A type, I∆N ≥ 30 mA) 0.05 x I∆N ±0.1 x I∆N
0.2 x I∆N … 2.2 x I∆N (B type) 0.05 x I∆N ±0.1 x I∆N
• LED Pass/Fail indicators: two LED in-
0.00 Ω … 19.99 Ω 0.01 Ω ±(5 % of reading + 5 digits)
dicators for PASS / FAIL evaluation of Earth resistance (EN 61557-5) 20.0 Ω … 199.9 Ω 0.1 Ω ±(5 % of reading + 5 digits)
test results are placed on both sides 200 Ω … 9999 Ω 1Ω ±(5 % of reading + 5 digits)
of the LCD Power supply 6 x 1.2 V rechargeable batteries, type AA
• Help screens: instrument comes com-
Overvoltage category CAT III / 600 V; CAT IV / 300 V
plete with built-in help screens for ref- V, reading up to 1000 MΩ. APPLICATION: Protection class Double insulation
erencing on site. • Trip Lock function: Zs (RCD) function
• Earth resistance measurement: in- • Initial and periodic testing of domestic COM port RS232 and USB
performs a loop impedance test with- and industrial installations;
strument performs 3-wire earth resist- Dimensions 140 x 80 x 230 mm
out tripping the RCD. • Testing of single and multiphase systems;
ance testing with two additional rods. Weight 1.0 kg
• Built-in fuse tables: this unique fea- • Multi-system testing: tests on single • Testing of TT and TN systems.
ture allows automatic evaluation of the and multiphase TT and TN systems.
line / loop impedance compared to the • Built-in charger & rechargeable bat-
STANDARDS: STANDARD SET:
regulations. teries: unit has a built-in charging cir-
• Online voltage monitoring: monitors cuit and comes complete with a set of Functionality: IEC/EN 61557
all 3 voltages in real-time. rechargeable NiMH batteries. Other reference standards for testing: • Instrument EurotestCOMBO • PC SW EuroLink PRO
• Upgradeable: if changes occur to the VDE 0413; IEC/EN 61008; IEC/EN 61009; • Set of carrying straps • Short instruction manual
• RCD auto: automated RCD testing pro- • Instruction manual and handbook on CD
regulations, upgrades can be made to IEC/EN/HD 60364; HD 384; BS 7671; • Test lead, 3 x 1.5 m
cedure significantly reduces test time. • Schuko-plug test cable, 1.5 m • Calibration certificate
the firmware to keep the instrument IEC/TR 60755; CEI 64.8; AS/NZ 3760;
• B type RCD testing is supported. • Test probe, 3 pcs (blue, black, green)
up to date. AS/NZ 3018
• PC SW Eurolink PRO included in the • Crocodile clip, 3 pcs (blue, black, green)
• Polarity swap: automatic polarity re- Electromagnetic compatibility: • Power supply adapter + 6 NiMH recharge-
versal on continuity test. the standard set enables download- IEC/EN 61326-1; IEC/EN 61326-2-2 able batteries, type AA
• Insulation range: wide range of insu- ing of test results and parameters and Safety: • USB cable
lation test voltages from 50 V to 1000 creation of test reports. IEC/EN 61010-1; IEC/EN 61010-031 • RS232 - PS/2 cable
Features Description
Insulation resistance – – –
Test voltage (VDC) 100 … 2500 50 … 1000 – – – 250 … 1000 500
INSULATION
Insulation resistance measuring range up to 100 GΩ up to 30 GΩ – – – up to 2 GΩ –
Diagnostic test (PI, DAR calculation) – – – – – –
Continuity of PE conductor with automatic polarity change,
CONTINUITY AND – – – –
test current 200mA
LOW RESISTANCE
MEASUREMENT Low resistance measurement (continuous measurement),
– – –
test current 7 mA.
Line impedance with Ipsc calculation – – – – –
LINE / LOOP Loop impedance with Ipsc calculation – – – – –
IMPEDANCE RCD Trip Lock loop impedance – – – – –
Built-in fuse tables for PASS / FAIL evaluation – – – – – –
Contact voltage without RCD tripping – – – – –
RCD trip-out time – – – – –
RCD TESTING RCD trip-out current with rising test current – – – – –
Automatic testing of RCDs – – – – – –
RCD type (general and selective) – – A , AC – – – A, AC (standard)
AC voltage measurement – – – –
VOLTAGE,
Online voltage monitor – – – – – –
FREQUENCY
Frequency measurement – – – –
PHASE SEQUENCE L1 - L2 - L3 – – – – –
Earth resistance 3-(4-)wire method – – – – –
Earth resistance 3-(4-)wire method with additional current clamp – – – Option – – –
EARTH, CURRENT
Earth resistance measurement with 2 current clamps – – – Option – – –
MEASUREMENTS
Soil resistance measurement – – – – – –
TRMS current – – – Option – – –
PASS / FAIL evaluation of test results – –
OTHER
Touch electrode – – – – –
FEATURES
Help menu – – – – –
COMMUNICATION RS232 – – –
PORTS USB – – –
Memory – – –
MEMORY, Number of memory levels / memory locations 2 / 1500 2 / 1500 3 / 1500 3 / 1500 – – –
SOFTWARE Professional PC SW Option Option Option Option – – –
Advanced PC SW Option Option Option Option – – –
CAT III / 600 V CAT III / 600 V CAT III / 600 V
Safety category CAT IV / 50 V – CAT III / 300 V CAT III / 300 V
CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V
Batteries 6 x AA 6 x AA 6 x AA 6 x AA 4xC 4xC 4 x AA
GENERAL DATA
Built-in battery charger – – –
Weight 850 g 850 g 930 g 850 g 410 g 490 g 600 g
Dimentions (mm) 140 x 80 x 230 140 x 80 x 230 140 x 80 x 230 140 x 80 x 230 280 x 70 x 80 280 x 70 x 80 200 x 100 x 50
KEY FEATURES
KEY FEATURES:
• Earth resistance measurement: in-
strument performs standard 4-wire
earth resistance tests with two earth-
ing rods and specific earth resistance
measurement.
• Selective earth resistance test: op-
tional 4-wire earth resistance measure-
ment in combination with an additional
current clamp is used for measuring
earth resistance of individual earthing Large LCD screen with backlight and PASS / Simple and fast manipulation. USB and RS232 communication ports.
rods. FAIL indicators.
• Contactless earth resistance test:
earth resistance measurement with 2
current clamps without breaking the STANDARD SET:
loop is intended for measuring resist- ing circuit and comes complete with a APPLICATION:
ance of individual earthing rods and is set of rechargeable NiMH batteries.
• Testing on TT and IT systems; • Instrument Smartec Earth / Clamp • Short instruction manual
reccomended first of all for urban ar- • Custom limits: the limits can be set on • Handbook on CD
• Testing sub-station earthing; • Soft hand strap
eas. any function, in that case large green • Test lead, 4.5 m (blue) • Calibration certificate
• Lightning system testing.
• Downloadable: downloads via RS232 • Test lead, 4.5 m (red)
and red lights of the LEDs will indicate
or USB cable directly to the PC with • Test lead, 20 m (green)
the help of the optional software. a PASS or FAIL evaluation of test re- • Test lead, 20 m (black)
STANDARDS:
• Upgradeable: if changes occur to the sult. • Earth test rod, 4 pcs
regulations upgrades can be made to • Easy to use: large bright LCD display Functionality: IEC/EN 61557 • Power supply adapter + 6 NiMH recharge-
the firmware to keep the instrument Other reference standards for testing: able batteries, type AA
and large buttons enable easy handling
IEC/EN/HD 60364; AS/NZ 3018; CEI • Instruction manual on CD
up to date. of the instrument (even while wearing
• Help screens: instrument comes com- 64.8; HD 384; BS 7671; VDE 0413
gloves).
plete with built-in help screens for ref- Electromagnetic compatibility:
erencing on site. • Magnetic holder: magnet for fixing IEC/EN 61326-1; IEC/EN 61326-2-2
• Built-in charger & rechargeable bat- instrument on metal surfaces enables Safety: IEC/EN 61010-1; IEC/EN 61010-
teries: instrument has a built-in charg- hands-free operation. 031; IEC/EN 61010-2-032
The MI 2126 Earth 2/3 is a high quality, professional grade test instrument for performing three-wire earth resistance The MI 3103 GigaOhm 1 kV tester is an easy to use installation tester with the ability to perform accurate resistance meas-
measurements in accordance with European standard EN 61557-5, on which the estimation of earthing quality is based. urements quickly and efficiently. Features including AC voltage testing, robust design, easy to read display and rotary
The equipment was designed and produced according to many years of experience of producing and dealing with earth switch (which can be used even while wearing gloves) make the MI 3103 Gigaohm 1 kV an extremely good value and
resistance and electric installation test equipment. versatile instrument to use.
The MI 2150 Installcheck is an easy to use electric installation safety test instrument for fast inspection of sockets and wir- The A 1143 Euro Z 290 A is a professional portable high current impedance tester. It performs high precision line and high
ing. Preset limits of basic safety parameters enables PASS / FAIL evaluation of test results which is displayed through LED precision fault loop impedance measurements in environments up to CAT IV / 310 V.
lamps. Installcheck completes safety check at the socket in only 5 seconds.
MEASURING FUNCTIONS:
MEASURING FUNCTIONS: • High precision line impedance;
• Continuity of protective conductors; • High precision fault loop impedance;
• Insulation resistance; • Contact voltage.
• Line resistance;
• Loop resistance; KEY FEATURES:
• Loop resistance without RCD tripping;
• RCD testing; • Independence: instrument is designed
• Phase rotation; to work independantly or in conjunc-
• PE terminal test. tion with: MI 2086 Eurotest 61557, MI
3101 EurotestAT, MI 3105 EurotestXA
and MI 3321 MultiServicerXA.
KEY FEATURES: • Range widening: adapts the instruments
to read from 0.1 mΩ up to 19.99 Ω.
• Preset limits enables evaluation of • Multi-system testing: works on both
test results. single phase and 3-phase systems
• PASS / FAIL indication: OK - LED (115 V to 440 V).
• IPSC and IPFC calculation: IPSC and IPFC
lamps confirms the on going measure- readings calculated up to 400 kA.
ment and indicates positive result of • 4-wire measurement for elimination of
the test. voltage drop on measuring leads.
• Acoustic signal confirms the comple- • Comfortable carrying: all the acces-
tion of test operations. sories are put in the strong, rugged,
• Flashing LED indicates the type of durable case of the instrument.
fault found in installation. • LCD: Built-in LCD for standalone meas-
urements.
APPLICATION:
APPLICATION:
• Domestic installation testing;
• High accuracy loop and line measure-
• Initial and periodic installation testing; ments;
• Testing of single phase and 3-phase sys- • Power transformer and motor winding
tems. measurement.
IEC/EN/HD 60364; AS/NZ 3018; STANDARD SET:
STANDARDS: CEI 64.8; BS 7671; VDE 0413
STANDARDS: Electromagnetic compatibility:
Functionality: IEC/EN 61557 IEC/EN 61326-1; IEC/EN 61326-2-2 • Instrument Euro Z 290 A
Electromagnetic compatibility: IEC/EN 61326 Functionality: IEC/EN 61557 Safety: IEC/EN 61010-1; • Test lead, 2-wire, 2 pcs
Safety: IEC/EN 61010-1; IEC/EN 61010-031 STANDARD SET: Other reference standards for testing: IEC/EN 61010-031 • Test lead, black, 2 m
• Test probe, red, 2 pcs
• Instrument Installcheck TECHNICAL DATA: • Crocodile clip, black, 3 pcs
TECHNICAL DATA: • Carrying belt • Crocodile clip, red, 2 pcs
• Schuko-plug test cable, 1 m • RS232 cable
• Test lead with test probe, 1.5 m, 2 pcs Function Measuring range Resolution Accuracy
• RS232-PS/2 cable
Function Test conditions Limit value (black, red) 0.1 mΩ … 199.9 mΩ 0.1 mΩ ±(5% of reading + 1 mΩ)
High resolution Line / Loop • Instruction manual
PE continuity Itest = 10 mA 2 Ω ± 0.5 Ω • Instruction manual 200 mΩ … 1999 mΩ 1 mΩ ±(5% of reading + 1 mΩ)
impedance measurement • Calibration certificate
Insulation resistance Utest > 500 VDC (0.6 … 1.2 MΩ) ± 0.2 MΩ • Calibration certificate 2.00 Ω … 19.99 Ω 10 mΩ ±(5% of reading + 10 mΩ)
RCD testing I∆N = 30; 100; 300; 500 mA Measuring voltage range 90 V … 530 V
- Contact voltage Itest < 0.5 x I∆N 25 V (at I∆N) ± 5 V Maximum test current (at 230 V) 154 A (10 ms)
Itest = I∆N; 5 x I∆N (30 mA 0,3 s (at I∆N) or 0,04 s (at Maximum test current (at 400 V) 267 A (10 ms)
- Trip-out time of RCD Maximum test current (at 530 V) 350 A (10 ms)
only) 5 x I∆N)
Fault loop resistance (with RCD) Itest < 0.5 x I∆N 25 V / I∆N Contact voltage 0 V … 100 V 1V ±(10% of reading + 3 digits)
Fault loop resistance (without RCD) Itest = 0.5 A 1.5 Ω ± 0.3 Ω Power supply 4 x 1.5 V alkaline batteries, type C
Line resistance Itest = 0.5 A 1.5 Ω ± 0.3 Ω Overvoltage category 310 V / CAT IV
Power supply 4 x 1.5 V alkaline batteries, type AA Protection class Double insulation
Overvoltage category CAT III / 300 V Pollution degree 2
Dimensions (W x H x D): 100 x 200 x 50 mm Dimensions 345 x 160 x 335 mm
Weight (without accessories): 0.6 kg Weight 5.0 kg
The MI 2093 Line Tracer is an universal instrument intended for tracing hidden conductive paths under plasters in walls, The ρ-Adapter is a special accessory intended for using only with METREL installation testers MI 3101 Eurotest
floors and ground or for determining one wire in a tuft of wires. Fuses or outlets belonging to a certain loop can be locat- AT and MI 3105 EurotestXA. It is designed for measurement of specific earth resistance.
ed as well. Line Tracer helps the operator to resolve hidden line problems easily (short circuits, interruptions, breakages).
KEY FEATURES:
FUNCTIONS: • Adapter is used for performing 4-wire
specific earth resistance measure-
• Tracing cables in walls, ceilings, floor
ments;
and ground;
• Designed for use in conjunction with
• Tracing live or voltage free cables;
the MI 3101 Eurotest AT and MI 3105
• Locating cable interruptions and short-
EurotestXA;
circuits in cables;
• The instrument comes complete with
• Locating concealed sockets and distri-
4-wire test lead, 15 m red extension
bution boxes;
lead, 2 earthing rods and carrying bag;
• Locating fuses and assignment to cir-
• Instruction manual contains step by
cuits;
step guide on how to perform the
• Determining an individual wire in a
measurement;
bundle of wires;
• It is recommended to use A 1199 in
• Tracing pipe installations and other
combination with 3-wire 20 m earth
conductive loops.
test lead set (S 2026).
The CS 2099 Eurocheck is a professional, multifunctional field calibrator intended for use with installation test instru- Demonstration Board MA 2067 is an excellent demonstration and educational tool that simulates real conditions in low
ments. Accuracy and functionality of all Metrel and most other manufacturer’s installation testers can be verified with voltage electrical installations. The Demonstration board consists of all significant elements of electrical installations like
the Eurocheck. The CS 2099 Eurocheck can provide a simple field calibration of the most frequently used functions when RCDs of different types, fuses, PE equalization bars, 1-phase and 3-phase sockets, various consumers of electrical energy and
testing installations. various grounding systems (TT, TN, IT). The MA 2067 Demonstration Board provides simulation of different types of faults in
electroinstallation. Complete testing and troubleshooting of the installation is possible by using suitable instruments.
FUNCTIONS:
KEY FEATURES:
• Insulation calibration with test voltage
• 65 different measurements in accord-
up to 1000 V; ance to EN 61557 are possible (in-
• Calibration of low resistance and conti- sulation resistance, continuity of PE
nuity functions; conductors, earth resistance, specific
• Fault loop and trip-lock RCD imped- earth resistance, line and loop imped-
ance functions calibration (all test ance, phase rotation, leakage current,
currents supported on Metrel instru- RCD testing, voltage and frequency).
ments); • 19 different errors can be selected on
• Calibration of RCD trip-out time func- a lockable distributor.
tion; • Different types of RCD are integrated
• Calibration of line impedance measur- for measurement of trip-out time, trip-
ing function; out current and contact voltage
• Calibration of voltage and frequency; • Simulation of TT, TN and IT earth sys-
• PE test terminal functional verification; tems.
• Automatic polarity verification • Possibility of connection to single
phase or 3-phase supply system.
• Booklet with theory and exercises for
APPLICATION: schools and training centers is includ-
• On-site testing of installation measur- ed in a standard set.
ing instruments;
• Occasional routine control of the safe-
APPLICATION:
ty testers.
• Education of students of electrotechni-
cal specialities;
STANDARDS: • Education and practical training of elec-
Electromagnetic compatibility: trical contractors about measurements
on low voltage electroinstallations;
IEC/EN 61326
• Demonstration on how to use different
Safety:
measurement instruments by sales
IEC/EN 61010-1
personnel.
• Instrument Eurocheck
• Small soft carrying bag TECHNICAL DATA:
• Instruction manual
Demonstration board MI 3099 simulates typical electrical installation usually met in individual houses or apartments Demonstration board MI 2166 simulates common electrical installation usually met in individual house or apartment.
with important elements on switchboard and on circut site. Demonstration board is intended for use preferably by sales Demonstration board is to be used preferably by sales personnel when demonstrating operation of electrical installation
personnel when demonstrating operation of electrical installation test equipment, especially the new Metrel’s electrically test equipment. Various test methods supported by different test instruments can be presented.
installations safety testers with built-in AUTOSEQUENCE procedure.
APPLICATION:
APPLICATION:
• Presentation of complete testing of
• Presentation of complete testing of
any electrical installation;
any electrical installation;
• Demonstration of electrical installation • Demonstration of electrical installation
test equipment operation by sales per- test equipment operation by sales per-
sonnel. sonnel.
TECHNICAL DATA:
STANDARDS: TECHNICAL DATA:
STANDARDS:
Electromagnetic compatibility: Power supply 230 V, 50 Hz
Power supply 230 V / 400 V, 50 Hz Electromagnetic compatibility: Overvoltage category CAT II / 300 V
IEC/EN 61326
IEC/EN 61326
Safety: Overvoltage category CAT II / 300 V Dimensions 450 × 330 × 110 mm
Safety:
IEC/EN 61010-1 Dimensions 480 × 387 × 136 mm Weight 3.56 kg
IEC/EN 61010-1
Weight 5 kg
EuroLink PRO and EuroLink PRO Plus Tree view installation structure can be easily rearranged by customer. PRO Test Report.
The EuroLink PRO / PRO Plus software works in conjunction with Metrel’s downloadable installation testers. The software
automatically finds the instrument and allows the test engineer to download test results saved on the instrument, review
the results, relocate test results (if required), print test reports and print installation structures for storing in the distribu-
tion board. With the more advanced Metrel installation testers, structures can be built with the software and uploaded
to the instrument for easy installation navigation while performing on-site testing. Additionally the EuroLink PRO Plus
software offers the ability to automatically generate professional PRO Plus Reports.
KEY FEATURES:
• Automatic recognition of the instru-
ment: when connecting your instru-
ment to the PC it is automatically rec-
ognized by the software.
• Simple graphical visualisation of the
installation structure: enables graphi-
cal representation of the tested instal-
lation which makes it easy to navigate
in the installation.
• 10-level structures: in conjunction
with MI 3105 and MI 3101 PC soft-
ware enables creating the electrical
installation structures with up to 10
levels.
• Rearranging of structures: the ele-
ments of the structure can be relocat-
ed and renamed.
• Installation structures printing: struc-
tures can be printed and stored in the PRO Plus Test Report.
distribution board for easier later iden-
tification of the installation elements.
• Structures upload: the installation
structure can be created in advance
on the PC and then simply uploaded • MI 3125B EurotestCOMBO PASSWORD PROTECTION:
to your tester (MI 3105, MI 3101, MI • MI 3121 SMARTEC Insulation / Con-
3125B only); if needed any deviations tinuity PC SW EuroLink PRO is password pro-
can be adjusted on the tester on site. • MI 3121H SMARTEC 2,5 kV Insula- tected for the following instruments:
• Export of test results: test results in tion / Continuity • MI 3121
text format can be exported to other • MI 3122 SMARTEC Z Line-Loop RCD
programs (MS Excel, MS Word). • MI 3121H
• MI 3123 SMARTEC Earth Clamp
• Automatic PRO Test Report genera- • MI 3122
tion: enables automatic generation of Key features of PRO Plus Test Reports: • MI 3123
PRO Test Report (low, medium and • Downloaded test results are automat- • MI 3125B
high detailed). ically inserted onto PRO Plus forms.
• Automatic PRO Plus Test Report • Allows to fill out visual inspection
generation (PRO Plus version only): PC SW EuroLink PRO Plus is password
form for tested fuse cabinet or earth-
enables automatic generation of PRO ing system. protected for all Metrel installation test-
Plus Test Report which include visual • Automatically selects worst case test ers.
inspection of tested object and test re- results for form completion.
sults in tabular form. • Easy test report generation and re-
viewing facilities. ORDERING INFORMATION:
PC SW EuroLink PRO / PRO Plus is com-
patible with: Eurolink PRO Plus enables creation of • A 1291 PC SW EuroLink PRO with
• MI 3105 EurotestXA the following test reports: USB and RS232-PS/2 cable
• MI 3101 EurotestAT • PRO Plus Test Report • A 1290 PC SW EuroLink PRO Plus
• MI 3102 EurotestXE • NICEIC certificates (UK)
• MI 3102H EurotestXE 2,5 kV (PRO with USB and RS232-PS/2 cable
• ZVEH certificates (Germany)
version only) • SiNa certificates (Switzerland) • A 1292 Upgrade code EuroLink PRO to
• MI 3002 EurotestLITE • UNE – 202008 certificates (Spain) EuroLink PRO Plus
Selection Guide for EIS Accessories Selection Guide for EIS Accessories
MI 3102H CL
MI 3102H CL
MI 3121H
MI 3125B
MI 3121H
MI 3125B
MI 3108
MI 3109
MI 3105
MI 3101
MI 3102
MI 3100
MI 3125
MI 2086
MI 2088
MI 3121
MI 3122
MI 3123
MI 2126
MI 3103
MI 2150
MI 2093
MI 3108
MI 3109
MI 3105
MI 3101
MI 3102
MI 3100
MI 3125
MI 2086
MI 2088
MI 3121
MI 3122
MI 3123
MI 2126
MI 3103
MI 2150
MI 2093
Part Part
Photo Description Target application Photo Description Target application
number number
Ro-adapter is intended for performing Very sensitive inductive sensor serves for
Selective probe for
A 1199 Ro-adapter earth resistance measurement in combi- – – – – – – – – – – – – – – – – – A 1192 contactless fuse and cable finding. To be – – – – – – – – – – – – – – – –
R10K
nation with installation safety tester. used with A 1191.
Test lead for R10K, Test lead with probe enables fast and ac-
EurotestPV PV remote unit for measurement and log-
A 1378 – – – – – – – – – – – – – – – – – A 1067 1.5 m, with built-in curate fuse finding and current circuit al- – – – – – – – – – – – – – – – –
Remote ging of irradiance and temperature values
resistor location. To be used with A 1191.
Luxmeter sensor, type B, for high-accu- Single phase 2-wire commander with test
Luxmeter sensor,
A 1172 racy illuminance measurement e.g. for – – – – – – – – – – – – – – – – A 1002 Tip commander tip and START and SAVE function keys for – – – – – – – – – – – – – – – – – –
type B (PS/2)
emergency lightning inspection. installation safety measurements.
Fuse / fault / cable locator is used for wire Single phase 2-wire commander with test
Fuse / fault / cable
A 1005 tracing, fuse identification and fault finding – – – – – – – – – – – – – – – – – – A 1176 Tip commander tip and TEST and MEM function keys for – – – – – – – – – – – – – –
locator
in low voltage electrical installations. installation safety measurements.
Selection Guide for EIS Accessories Selection Guide for EIS Accessories
MI 3102H CL
MI 3102H CL
MI 3121H
MI 3121H
MI 3125B
MI 3125B
MI 3108
MI 3109
MI 3105
MI 3101
MI 3102
MI 3100
MI 3125
MI 2086
MI 2088
MI 3121
MI 3122
MI 3123
MI 2126
MI 3103
MI 2150
MI 2093
MI 3108
MI 3109
MI 3105
MI 3101
MI 3102
MI 3100
MI 3125
MI 2086
MI 2088
MI 3121
MI 3122
MI 3123
MI 2126
MI 3103
MI 2150
MI 2093
Part Part
Photo Description Target application Photo Description Target application
number number
Tip commander, Single phase 3-wire commander with test 2-wire test lead for continuity and insula-
Test lead, 2 x
A 1194 3-wire (for MI tip, TEST and BACKLIGHT function keys – – – – – – – – – – – – – – – – – A 1055 tion resistance measurements on electri- – – – – – – – – – – – – – – – – – –
1.5 m
3100) for installation safety measurements. cal installations.
Tip commander, Single phase 2-wire commander with test Test cable for simultaneous AC/DC power
A 1244 2-wire (straight tip, TEST and SAVE function keys for in- – – – – – – – – – – – – A 1385 PV fused test lead and efficiency measurements of PV invert- – – – – – – – – – – – – – – – – –
cable) stallation safety measurements. ers.
Selection Guide for EIS Accessories Selection Guide for EIS Accessories
MI 3102H CL
MI 3102H CL
MI 3121H
MI 3121H
MI 3125B
MI 3125B
MI 3108
MI 3109
MI 3105
MI 3101
MI 3102
MI 3100
MI 3125
MI 2086
MI 2088
MI 3121
MI 3122
MI 3123
MI 2126
MI 3103
MI 2150
MI 2093
MI 3108
MI 3109
MI 3105
MI 3101
MI 3102
MI 3100
MI 3125
MI 2086
MI 2088
MI 3121
MI 3122
MI 3123
MI 2126
MI 3103
MI 2150
MI 2093
Part Part
Photo Description Target application Photo Description Target application
number number
Set of 4 test leads is intended for two Insulated rod for Insulated rod enables insulation resistance
Test lead set, 2 m,
S 2009 clamp earth resistance measurement to – – – – – – – – – – – – – – – – – – A 1201 CONTINUITY and continuity measurement on hard-to- – – – –
4 pcs
connect current clamps on the instrument. measurement reach objects, e.g. luminaries.
Crocodile clip assures secure and perma- Large soft carrying bag for transport and
Crocodile clip,
A 1013 nent contact during the measurement on – – – – A 1289 Soft carrying bag storage of test instrument and belonging – – – – – – – –
black
bus bars, fixing screws, etc. accessories.
Crocodile clip assures secure and perma- Protection case with plastic screen for
A 1310 Crocodile clip, blue nent contact during the measurement on – – – – – – – – – A 1115 Protection case protection of the tester against dirt and – – – – – – – – – – – – – – – – – –
bus bars, fixing screws, etc. damage.
MI 3102H CL
MI 3121H
MI 3125B
MI 3108
MI 3109
MI 3105
MI 3101
MI 3102
MI 3100
MI 3125
MI 2086
MI 2088
MI 3121
MI 3122
MI 3123
MI 2126
MI 3103
MI 2150
MI 2093
Part
Photo
number
Description Target application Power Quality Analysis
LAN Cabling Certification
Set of carrying straps for carrying the
Set of carrying
A 1302
straps
measuring instrument around the neck al- – – – – – – – – – – – – – –
lowing free hand use of the tester.
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
A 1303 Soft hand strap Soft hand strap for holding the instrument. – – – – – – – – – – – – – –
Voltage and Continuity Testers
Variable transformers /
Holder enables free hand operation with
Holder for com-
A 1245 the tester by fixing the test commander – – – – – – – – – – – – – –
mander
and other test cables when not in use. Equipment for laboratories and Schools
3-phase test adapter for installation safe-
Three phase
A 1110 ty testing on 3-phase sockets type 16 A – – – – – – – –
adapter
3CEE.
GOOD TO KNOW
3-phase adapter with selection switch for
A 1111
Three phase installation safety testing on 3-phase sock-
High Voltage Insulation / Continuity / Earth 2 - 02
A 1215
(for
adapter with ets type 16 A 3CEE. The adapter allows – – – – – – – Selection Guide for CONTINUITY Insulation Testers 2 - 06
switch seamless switching between measure-
MI 2150)
ments.
Selection Guide for HV Insulation Testers 2 - 07
EARTH TESTER
RS232 / USB MI 3295 Step Contact Voltage Measuring System 2 - 08
RS232 / USB adapter for instruments with-
A 1171 adapter with 1 m – – – – – – – – – – – – – – – – –
out USB comunication port. CONTINUITY TESTERS
cable
MI 3252 MicroOhm 100A 2 - 10
PC SW Eurotest PC Software Eurotest2Mobile / Smart- MI 3252 MicroOhm 10A NEW 2 - 12
2Mobile/Smart phone enables Bluetooth connection between
A 1293
phone with modem Smart Mobile phones and Metrel installation
– – – – – – – – – – – – – – – – – MI 3242 MicroOhm 2A NEW 2 - 14
and data cable safety testers. HIGH VOLTAGE INSULATION TESTERS
MI 3200 TeraOhm 10 kV 2 - 16
A 1017
Communication RS232 interface cable for connecting the
– – – – – – – – – – – – – – – – –
MI 3201 TeraOhm 5 kV Plus 2 - 18
cable RS232 instrument with the PC.
MI 2077 TeraOhm 5 kV 2 - 20
MI 3202 GigaOhm 5 kV 2 - 22
Barcode scanner for identification of bar- PC SOFTWARE
code labelled installation structure ele-
A 1105 Barcode scanner – – – – – – – – – – – – – – – HVLink PRO 2 - 24
ments like sockets, switches, fuses,
switchboards, etc. DEMONSTRATION BOARD
MI 3299 HV demo BOX 2 - 26
AM 1337 RFID HGL RFID reader – – – – – – – – – – – – – – – – – Selection Guide for HV Accessories 2 - 27
CATALOGUE 2012/13
Option – Not available
Itot
High Voltage Insulation / Continuity / Earth IRiso IRCpi ICiso
Rtot High Voltage Insulation / Continuity / Earth
Good insulation
Riss1
Riss1
IRiso
IRiso
IRCpi
CpiIRCpi
ICiso
RIiso +
Cpi +
U
Rtot Good insulation
Riss1 Ciso
rent IRCpi is small compared to the others. tion with nominal electrical voltages.
of the Uresistance over a period. This is Ustart
0DC voltage testing and AC voltage Rather than measuring the polarization
start
U Applied test voltage 0 Ub
µA 0 Tslope U5 Ttest t caused by the absorption
0 Varistor that can beDefective t Ustart
Riss1 & Riss2 Surface leakage resistances testing AC testing breakedown insulation current during an insulation test, the di- The device under test is exposed to dif-
40
Riso Insulation resistance AC testing is U4more suitable for per- clearly 0seen. The absorption effect lasts electric
0 discharge (DD) test can be per- ferent test voltages that are applied in
Isf 0 than the Tslope Ttest t 0 Varistor Defective t
Ciso ICiso Insulation capacitance forming withstanding or dielectric tests. far longer time required for formed. DD test is carried out
breakedown after the
insulation steps. The voltage starts at the lowest 0
Tslope Ttest
30 U3 0 t
Rpi IRiso
Polarization resistance While DC test gives more qualitative pic- charging the capacitance of the insula- completion of the insulation resistance value and increases with defined steps Measuring procedure for withstanding voltage measure-
20
Cpi Polarization capacitance ture about the tested U2 insulation. tion. measurement. Typically the insulation up to the highest level. ment.
IRiss
10 U1
IRCpi
0 0
800 t (s)
2. 2 2. 3
0 200 400 600 0 T1 T2 T3 T4 T5 t
Accessories: page 2.27 Accessories: page 2.27
µA
Itot
40
HV, Step / Contact Voltage and Earth Resistance HV, Step / Contact Voltage and Earth Resistance
0 200 400 600 800 t (s)
Maximum time of exposure Voltage Earth resistance measurement Typical connections for:
U
> 5 s to ∞ UC ≤ 50 VAC or ≤ 120 VDC For the earthing resistance test a voltage
< 0.4 s UC ≤ 115 VAC or ≤180 VDC and current probe (serves as auxiliary
< 0.2 s UC ≤ 200 VAC earth) are used. Because of the voltage
< 0.04 s UC ≤ 250 VAC funnel it is important that the test elec-
Ustart Maximum time durations vs fault voltage trodes are placed correctly.
Ub
Selection Guide for CONTINUITY Insulation Testers Selection Guide for HV Insulation Testers
MEASUREMENTS MEASUREMENTS
Measuring range 1 nΩ ... 20 Ω 100 nΩ ... 2 kΩ 1 µΩ ... 200 Ω Test voltage range 500 VDC … 10 kVDC 250 VDC … 5 kVDC 250 VDC … 5 kVDC 250 VDC … 5 kVDC
No. of ranges 6 7 6 250 V; 500 V; 1 kV;
Voltage steps 25 V 25 V 50 V
Current into load 2 mΩ at 100 A 200 mΩ at 10 A 1 Ω at 2 A 2.5 kV; 5 kV
Highest resolution 1 nΩ 0.1 µΩ 1 µΩ Insulation resistance measuring range 10 TΩ 10 TΩ 5 TΩ 1 TΩ
Basic accuracy 0.25 % 0.25 % 0.25 % Calculation of DD, DAR, PI −
Test current 100 A, 50 A, 10 A, 1 A, 100 mA 10 A, 1 A, 100 mA, 10 mA, 1 mA 2 A, 100 mA, 10 mA Withstanding voltage test −
OTHER FEATURES Voltage ramp test −
Single, Automatic, Inductive, Single, Automatic, Inductive, Leakage current measurement −
Measurement modes Single, Continuous
Continuous Continuous Capacitance measurement −
Test method 4-wire, unidirectional 4-wire, Bidirectional 4-wire, Bidirectional Short circuit / charge current 5 mA 5 mA 1.4 mA 5 mA
Autoranging − Voltage measurement AC / DC up to 600 V up to 600 V up to 600 V up to 600 V
PASS / FAIL indication OTHER FEATURES
Temperature compensation − − Programmable timer −
COMMUNICATION PORTS Automatic discharge after test
RS232 Graph R(t) − −
USB Bar graph
MEMORY, SOFTWARE Auto adjustment function
Memory Auto ranging
Number of memory locations 1000 / 2 levels 1000 1500 Audible warnings
Software HVLink PRO HVLink PRO HVLink PRO Guard terminal
GENERAL DATA Shielded test leads Option
Display type Graphical LCD Graphical LCD Graphical LCD COMMUNICATION PORTS
Backlight USB Option −
CAT IV / 50 V CAT IV / 300 V CAT IV / 300 V RS232 −
Safety category
CAT II / 300 V CAT II / 300 V CAT III / 600 V MEMORY, SOFTWARE
Rechargeable batteries Memory −
Battery 12 V / 12 Ah 6 x NiMH, type HR14 6 x NiMH, type AA Number of memory locations 1000 1000 1000 −
Built-in battery charger − Software Option (HVLink PRO) Option (HVLink PRO) Option (TeraLink) −
Low battery indication GENERAL DATA
115 / 230 V AC, 50 / 60 Hz, 200 Display type Graphical LCD Graphical LCD Graphical LCD Custom LCD
Mains voltage 90-260 V AC, 45-65 Hz, 50 W −
VA
Backlight
Weight 11.8 kg 2.8 kg 0.8 kg
Safety category CAT IV / 600 V CAT IV / 600 V CAT III / 600 V CAT IV / 600 V
Dimensions (mm) 410 x 175 x 370 310 x 130 x 250 140 x 80 x 230
Rechargeable batteries Option
Built-in battery charger
Low battery indication
Battery life (no load connected) 4 h at 10 kV 4 h at 5 kV 4 h at 5 kV 4 h at 5 kV
Weight 5.5 kg 3 kg 2.1 kg 3 kg
Dimensions (mm) 345 x 160 x 335 310 x 130 x 250 265 x 110 x 185 310 x 130 x 250
KEY FEATURES:
• Accurate: 0.1 nΩ best resolution with STANDARD SET:
0.25% accuracy.
• Bar graph: on screen resistance bar • Instrument MI 3250 • PC SW HVLink PRO
graph. • Test cable, 2 m, with Kelvin Clip, 2 pcs • Bag for accessories
• Battery powered: more than 1000 • Test cable, 2 m, 4 pcs (2 x black, 2 x red) • Instruction manual
• Crocodile clip, 4 pcs (2 x black, 2 x red) • Calibration certificate
measurements with 10 A test current
• Test probe, 2 pcs (red, black)
can be performed when powered by
• Mains cable
internal battery only. • USB cable and RS232 cable
• Safe: High overvoltage category CAT • NiMH rechargeable batteries, type C, 6 pcs
IV / 300 V.
• Four measuring modes: Automatic,
single, continuous and inductive KEY FEATURES
• Automatic thermal EMF elimination:
with automatic bidirectional measure-
ment .
• Temperature compensation: meas-
ured resistance can be adjusted ac-
cording to ambient temperature, which
can be entered manually or measured
by external probe
• Custom limits: limits can be set for
PASS/FAIL evaluation of test results.
• Portable: lightweight 3 kg design with
carry handle and shoulder strap. APPLICATION: STANDARDS: Fast and simple adjustment of the test Test lead connection terminal with four
Large analogue / digital LCD with backlight
• Memory: built-in memory enables parameters banana safety sockets.
Measurement the resistance of: Electromagnetic compatibility:
storage of up to 1000 test results. • Bus bar joints
• Downloadable: stored test results • Motor and transformer windings IEC 61326-1
can be via RS232 or USB interface • Cables
transferred to the PC with installed • Fuses Safety:
HVLink PRO software, which enables • Aircraft frame bonds
downloading, review, analyses and • Rail and pipe bonds EN 61010-1;
printing of the test results. • Lightning conductor bonding EN 61010-031
APPLICATION:
• Testing insulation resistance of rotat-
ing machinery and cables;
• Production line periodic testing and
STANDARD SET:
maintenance;
• Troubleshooting and analysis of all
kinds of insulation problems. • Instrument GigaOhm 5 kV
• Mains cable
• 10 kV shielded test lead with probe, black, 2 m
• 10 kV shielded test lead with probe, red, 2 m
STANDARDS:
• 10 kV crocodile clip, 2 pcs (black, red)
Functionality: • Guard lead, green, 2 m
IEC/EN 61557-2 • Crocodile clip, green
• 6 x 1.2 V NiMH rechargeable batteries, type C
Electromagnetic compatibility: • Handbook on CD
EN 61326 class B • Instruction manual
Safety: EN 61010-1; EN 61010-031 • Calibration certificate
HVLink PRO
User friendly interface with tree view
The HVLink PRO software works in conjunction with Metrel newest HV insulation testers, Step Contact Voltage Measuring
data structure and full, medium or low
System and MicroOhms. The software automatically recognizes connected instrument and allows the customer to down-
representation of test results.
load test results saved on the instrument, review the results, rename and relocate data if needed and print test reports.
KEY FEATURES:
• Automatic recognition of the instru-
ment: when connecting your instru-
ment to the PC it is automatically rec-
ognized by the software.
• Tree view: all the results are repre-
sented in tree view for easy data man-
agement.
• Rearranging of structures: the ele-
ments of the tree structure can be re-
located and renamed.
• R(t) graphs: if graph R(t) was enabled
when testing with the instrument MI
3200 or MI 3201 then it can be plotted R(t) graph can be drawn for HV Insula-
tion Resistance measuring functions.
and printed with the software.
• Measurement tables: if graph R(t)
was enabled when testing with the
instrument MI 3200 or MI 3201 then
a table with fixed R(t) values can be
viewed and printed.
• Export of test results: test results in
text format can be exported to other Test report
programs (MS Excel, MS Word).
• Automatic Test Report generation:
enables automatic generation of Test
Report (low, medium and high de-
tailed).
PASSWORD PROTECTION:
PC SW HVLink PRO is password pro-
tected for the following instruments:
• MI 3200
• MI 3201
ORDERING INFORMATION:
• A 1275 PC SW HVLink PRO with USB
and RS232-PS/2 cable
The MI 3299 High voltage Demonstration Box 10 kV has been developed for demonstration purposes at high voltage
MI 3295
MI 3252
MI 3250
MI 3242
MI 3200
MI 3201
MI 2077
MI 3202
insulation diagnostics. It simulates typical electrical insulation usually met in the industrial environment. It is equipped Part
with high quality resistors in different ranges, high voltage capacitors and a discharge facility to simulate a breakdown Photo Description Target application
number
phenomenon in gases. Additionally measurements of polarization index (PI), dielectric discharge (DD) and dielectric ab-
sorption ratio (DAR) can be demonstrated. Packed with all these features the demonstration box is also well suited for Additional MI 3295M Set for simultaneous measurements
basic calibration of DC high voltage insulation resistance measuring instruments. MI Step Contact Meter
of step voltage and contact voltage on different test points.
Set includes instrument MI 3295M, test lead, 2 x 3 m, soft – – – – – – –
3295M Measuring Set
carrying bag, soft carrying neck belt, NiMH battery, type AA,
Set
6 pcs, Power supply adapter.
Communication cable RS232 interface cable for connecting the instrument with the
A 1017 – – – – –
RS232 PC.
APPLICATION: TECHNICAL DATA: RS232 / USB adapter RS232 / USB adapter for instruments without USB comuni-
A 1171 – – – – – – –
with 1 m cable cation port.
• Demonstration of insulation diagnos-
tics measurement with DC test volt- Dimensions 440 × 320 × 110 mm
age; Weight 4 kg
PC Software TeraLink supplied with RS232 interface cable
• Demonstration of functionality of HV PC SW TeraLink with
A 1056 supports test results downloading and creation of test re- – – – – – – –
RS232 cable
insulation measuring instruments; ports.
• Training centres, schools, laboratories;
• Basic calibration of DC high voltage in- STANDARD SET: HVLink PRO is a downloading and data management PC soft-
sulation testers. ware with R=f(t) graph printing functionality (for HV insulation
A 1275 PC SW HVLink PRO – – – –
testers). It comes delivered with RS232 and USB communica-
• HV demo BOX 10 kV
tion cables.
• HV test leads, 2 pcs
STANDARDS: • Instruction manual Resistor SHUNT, Resistor SHUNT is used for testing correctness of mirco
A 1333 – – – – – –
• Handbook on CD 750 µΩ ohmmeters.
Safety:
EN 61010-1 • Calibration certificate
MI 3295
MI 3252
MI 3250
MI 3242
MI 3200
MI 3201
MI 2077
MI 3202
MI 3295
MI 3252
MI 3250
MI 3242
MI 3200
MI 3201
MI 2077
MI 3202
Part Part
Photo Description Target application Photo Description Target application
number number
Set of 5 kV shielded test leads with test probe and Guard test
5 kV shielded test
Step voltage probe lead with crocodile clip for MI 2077 improves accuracy of HV
A 1353 Additional voltage probes for step voltage measurements. – – – – – – – S 2042 lead with test probe, – – – – – – –
(25 kg), 2 pcs insulation resistance measurement in environments with high
10 m, 2 pcs
content of external electromagnetic interferences.
5 kV shielded test 5 kV shielded test leads with test probe improve accuracy of
A 1012 Test lead, green, 4 m Extension test lead. – – – – S 2044 lead with test probe, HV insulation resistance measurement in environments with – – – – – – –
15 m, 2 pcs high content of external electromagnetic interferences.
Temperature probe Temperature probe with measuring range from -55 °C to Small soft carrying Small soft carrying bag for transport and storage of test in-
A 1383 – – – – – – – A 1271 – – – – –
with 2 m cable +125 °C for measurement of ambient temperature. bag strument or accessories.
Test cable Kelvin Test cable with 500 A Kelvin clamps for easy and accurate Large soft carrying bag for transport and storage of test in-
A 1407 – – – – – – – A 1006 Soft carrying bag – – – – – – –
500 A, 2,5 m resistance measurements with MI 3242 strument and belonging accessories.
Test cable Kelvin, Test cable with Kelvin clamps for easy resistance measure-
A 1408 – – – – – – –
2,5 m ments with MI 3242
5 kV test lead set, 5 kV test lead set, including 2 test leads and 2 crocodil clips,
S 2003 – – – – – – –
2 m, 2 pcs for safe insulation testing.
GOOD TO KNOW
Testing the safety of electrical appliances 3 - 02
PAT TESTERS
Selection Guide for PAT testers 3 - 05
MI 3305 OmegaGT Plus and MI 3304 BetaGT Plus 3 - 06
MI 3310A SigmaGT and MI 3310 SigmaGT 3 - 08
MI 3309 DeltaGT 3 - 10
MI 3311 GammaGT 3 - 12
MI 2142 AlphaPAT 3 - 14
OTHER INSTRUMENTS / ADAPTERS / ACCESSORIES
A 1322 Active 3-phase Adapter NEW 3 - 16
DEMONSTRATION BOARD
MI 3300 Portable Appliance Simulation Board 3 - 18
GOOD TO KNOW
Testing the safety of electrical appliances, machines and switchboards 3 - 20
MACHINE AND SWITCHBOARD TESTERS
Selection Guide for Machine and Switchboard testers 3 - 23
MI 2094 CE MultiTester 3 - 24
MI 3321 MultiServicerXA 3 - 26
MI 2170 MultiServicer 3 - 28
PC SOFTWARE
PATLink PRO and PATLink PRO Plus 3 - 30
Selection Guide for PAT Accessories 3 - 32
CATALOGUE 2012/13
2. 30 Accessories: page 2.27 Accessories: page 3.32
Appliance / Machine / Switchboard Safety Appliance / Machine / Switchboard Safety
GOOD TO KNOW GOOD TO KNOW
Find out more about testing safety of • Power supplies; ered as class II parts and are checked in Measurement of load and leakage
electrical equipment. • Heating appliances; the Touch Leakage test. currents with current clamps
Primary goal of testing safety of elec- • Handheld tools; Advantages of clamp measurements are:
trical equipment is to use all electrical • Luminaries; Differential leakage current test • Measured electrical equipment does
equipment without danger. Common ac- • Consumer electronic; Differential leakage measures the dif- not need to be disconnected from the
cidents caused by electrical equipment • Information and communication tech- ference in current between the live and mains.
are: nology (computers, fax machines, Substitute leakage test for Class I device neutral cable which provides a true value • Selective current tests can be per-
• Injuries through electric shock caused scanners, etc.);
Earth bond test
of how much current the appliance leaks formed by embracing individual con-
by malfunctioned equipment; ductors.
• Prolongation cords, IEC supply cords; AC test signal is applied between con- to ground.
Test signal is applied between PE pin • Individual currents can be measured
• Injuries through overheated equip- • Appliances for medical use. nected live pins and PE contact of supply
of supply cord and accessible earthed without disconnections.
ment; cord. Isolated accessible metal parts are
• Fire and explosions. Classification of appliances by protec- metal parts. NOT included in this test and are meas- Current clamps are best suited for:
tion classes: ured as Class II items. • functional testing of fixed installed ap-
To prevent risk and possible danger According to the design electrical equip- Insulation resistance pliances;
caused by using electrical appliances ment can be divided in three classes. In Insulation resistance between live con- • functional testing of appliances with
and other equipment appropriate safety the table below the differences between ductors and all accessible metal parts nominal currents >16 A;
Differential leakage current test for Class I device
testing procedure should be performed. classes are described. (earthed and isolated) is checked. This • troubleshooting of current paths in ap-
Testing of electrical equipment is not test discloses faults caused by pollution, pliances.
regulated the same way in all countries. Class I II III Appliance must be powered on. The
moisture, deterioration of insulation ma- leakage current is measured as the dif-
For instance in Germany, UK, Australia
testing of all electrical equipment is
Marking no
III terial etc. Substitute leakage test for Class II device ference of currents through L and N
strictly regulated by law. Through their yes conductors. Unearthed accessible metal
positive experience it can be assumed Connection to all accessible
AC test signal is applied between con- parts are not included in this test. They
that other countries will follow in the fu- protection (PE) metal parts no connection nected live pins and accessible isolated are considered as class II parts and are
no
conductor of (case etc.) are to mains metal part. checked in the Touch Leakage test.
ture. the installation. connected to
the PE connec- Current measurement with current clamps
tion. Leakage current tests Touch leakage test
Safety of electrical equipment depends In this test the sum of leakage currents
on different factors which can improve Basic insulation performed performed
performed /
Insulation resistance test for Class I device Leakage leakage current is a current that Appliance must be powered on. By
looser limits caused by appliance insulation resist-
or worsen the safety level. would flow via the isolated accessible embracing separate conductors load or
not needed ances (resistive currents through the in-
in general, metal part (if touched) through body to leakage currents can be measured.
100 % Supplementary High DC voltage test signal is applied be- sulation material, fault currents through
or reinforced
needed if there
performed not needed decreased insulation) and capacitances ground are measured in this test.
Remaining risk
insulation
are acces- tween connected live pins and PE con- Functional test
Periodic retests Age sible unearthed
tact of supply cord. Unearthed accessi- (capacitive leakage current) is checked.
metal parts 1) Functional check explores if the appli-
ble metal parts are NOT included in this Excessive leakage currents are most
Correct service and maintenance
three pole (L,N, can be two ance is working properly. The use of
Wear Supply cord two pole often caused by deterioration of the
Correct use PE) pole test and are measured as Class II items. more sophisticated measuring instru-
appliance insulation (pollution, ageing,
Independent certification must be ments permits load testing, which is an
Harsh installation supplied from moisture) or faults in mains circuits of
Type test effective way of determination if there
conditions
Notes
must have ad- a SELV (safety appliances.
Adequate design equate earthing low voltage) are faults in the appliance.
resistance source, typically
Consideration of safety standards Damage 12 V or 24 V In general three leakage currents are Touch leakage current test for Class II device
its and parameters must be selected. MI 3305 MI 3304 MI 3310A MI 3310 MI 3309 MI 3311 MI 2142
Part No.
It is of a great advantage if this can be OmegaGT Plus BetaGT Plus SigmaGT SigmaGT DeltaGT GammaGT AlphaPAT
made automatically by the measuring
instrument.
KEY FEATURES:
• Autosequencing: built in Autose-
quences speed up testing and ensure
no tests are missed.
• Automated: automatic testing and
Pass/Fail evaluation of results accord-
ing to the code of practice.
• Adaptable: tests both 230 V appli-
ances and 115 V appliances (via socket
adapter included in standard set).
• Multi-tasking: can perform Hard and Mobile phone type keypad for fast entering Input / output ports: barcode reader, Small and lightweight design makes AlphaPAT
of appliance data and date. RFID reader / writer, printer, PC. ideal for PAT testing on variety of environments.
Soft Earth Bond test, 250 V / 500 V in-
sulation tests, differential /substitute
STANDARDS: STANDARD SET:
/ touch leakage test, Load tests, fuse
tests and polarity tests. Functionality:
• Intelligent: hard or soft tests are cho- VDE 0701;
sen automatically to reduce the risk of VDE 0702;
damage occurring on the selected ap- BS 89;
pliance. IEC 60335-1;
• Downloadable: with memory capac- IEC 60598-1;
ity of 1100 locations, the unit can be
IEC 60745;
downloaded to a computer via the
IEC 60950
PATLink software (included in the
standard set).
Protection class I
The MI 3300 PAT Demoboard is an excellent instrument for teaching or demonstrating PAT testing. The MI 3300 simulates Nominal input voltage 230 V
a wide variety of portable equipment in normal operation or in fault conditions with the simple flick of a switch. The Optional on request 115 V
strong rugged portable case with detachable lid allows the unit to be easily moved between sites. The ability of the unit Power consumption 15 VA max.
to simulate unlimited number of different equipment and the possibility to set fault conditions make the PAT Demoboard Overvoltage category CAT II / 300 V
the ideal unit for teaching or assessing learning in classrooms, training sessions, demonstration sessions, seminars and
Frequency range 45 Hz … 66 Hz
on PAT training courses.
Pollution degree 2
Dimensions 345 x 160 x 335 mm
Weight 2.76 kg
KEY FEATURES:
Normal and fault conditions can be switched
• Practically unlimited number of differ- on and off.
ent equipment (portable appliances,
machines and switchgears) can be
simulated by using different tables
(eight are included in a standard set).
• On demand the demonstration board
can be simply upgraded with new ta-
bles.
• Normal and fault situations can be
switched on and off, offering fault con-
ditions for the assessment of learning.
• Demoboard simulates the following
faults: PE continuity faults, insulation
resistance faults, leakage and touch
leakage faults, polarity and functional
faults. 8 demonstration tables (iron, receiver, IEC
• The demonstration board is built into a cord, extension drum, coffee machine,
strong rugged case with a handle and washing machine, switchgear)
detachable lid for storing leads, adapt-
ers and manuals.
APPLICATION:
STANDARD SET:
• Presentation of complete safety test-
ing of any portable appliance, machine
MI 3300 • Test cable for discharge time testing
or switchgear;
• Instrument PAT Demoboard • Carrying bag for demonstration tables
• Demonstration of PAT test equipment • 8 demonstration tables (iron, receiver, IEC • Handbook “Electrical Equipment Testing”
operation by sales personnel. cord ,extension drum, coffee machine, on CD
washing machine, switchgear) • Instruction manual
• Jumper • Calibration certificate
STANDARDS: • IEC cord
• Mains cable
Safety: • Class I mains cable
EN 61010-1 • Class II mains cable
Testing the safety of machines and switchboards Testing the safety of machines and switchboards
Find out more about testing safety of • Insulation resistance test; form. The standard EC/EN 60204, Ed.5 Insulation resistance test Components and devices that have
machines. • High voltage test; allows simplified testing procedures re- This test discloses faults caused by pol- been voltage tested in accordance with
Typical hazardous situations related to • Protection against residual voltages; garding to the status of machine. lution, moisture, deterioration of insula- their product standards may be discon-
electrical equipment are: • Functional tests. tion metal, etc. nected during testing.
• failures or faults in the electrical equip- The status of the machine can be select-
ment resulting in the possibility of Safety - measurements: ed on base of: Insulation resistance between live con-
electric shock or electrical fire; Loop impedance and prospective fault
Visual test • Condition of supplied machine (dis- ductors and accessible (earthed or iso-
• failures or faults in control circuits re- A visual check must be carried out be- mantled, fully assembled); lated) metal parts is checked. current Testing of RCD in electrical installation
sulting in the malfunctioning of the fore each electrical safety test. • Technical documentation (availability The instrument measures the imped-
machine; of existing verification report of electri- ance of the fault loop and calculates the Discharge Time
• disturbances or disruptions in power The visual inspection discloses most of cal wiring of machine); prospective fault current. The results If large capacitors in machines are dis-
sources as well as failures or faults in faults! • Length of conductors after installation; can be compared to limit values set on connected from supply there is often a
the power circuits resulting in the mal- • Incoming supply characteristics - loop remaining (residual) charge on internal
base of selected protective circuit break-
functioning of the machine; A thorough visual check must be carried impedance. machine components.
• loss of continuity of circuits that de- ers or RCDs. The measurement com-
out before each electrical safety test.
pends on sliding or rolling contacts, plies with requirements of the standard
How to select the appropriate machine Insulation resistance test Live parts having a residual voltage
resulting in failure of a safety function; EN 61557-3.
Check of: status and test extent is described in greater than 60 V after the supply has
• electrical disturbances either from out- • Wiring connection points. Especially EN/IEC 60204, Table 9. Components and devices that are not been disconnected, shall be discharged
side the electrical equipment or inter- PE connections are important ! rated to withstand the test voltage shall to 60 V or less within a time period of 5 s
nally generated, resulting in the mal- • Protection covers, housings Once the machine status and test extent be disconnected during the testing. after disconnection of the supply.
functioning of the machine;
• Inscriptions and markings related to are defined the limits for the Continuity
• release of stored energy (either electri-
safety must be clearly readable. and/or ZLOOP test should be defined. Lower test voltages should be used For plugs or similar devices with ex-
cal or mechanical) resulting in electric
• Cable layout, radiuses, isolation for sensitive electronic equipment and posed conductors (for example pins) if
shock or unexpected movement that
• Switches, regulators,lamps, keys Continuity test surge protective devices. plugged out it shall be discharged to 60
can cause injury;
• Parts subjected to wear out This test determines that the PE and Loop impedance test V or less within a time period of 1 s after
• audible noise at levels that cause
• Electrical and mechanical protection equipotential connections inside the ma- High voltage withstanding test
health problems to persons; disconnection of the supply.
devices (barriers, switches, fuses, chine have proper resistance that corre- The HV withstanding test is used to con-
• surface temperatures that can cause RCD testing
alarms) sponds to their length and cross-section. firm integrity of the insulation materials.
injury. Various test and measurements are re-
• Openings, filters During the test the insulation materi-
To verify the electrical safety of ma- • Technical documentation, instructions Size of test current should be between als in the machine are stressed with a quired for verification of RCDs in RCD
chines the appropriate measurements for use available at least 0.2 A and approximately 10 A higher voltage than during normal opera- protected machines. Measurements are
should be performed: • Installation of the appliance must be Higher currents are preferred ,especial- tion. A powerful AC high voltage source complies to the EN 61557-6 standard.
• after erection of machine; performed according to the user man- ly for low resistance values, i.e. larger is applied between the live/ neutral input
• after installation of machine; uals. cross sectional areas and/or lower con- terminals and the metal housing of the
Discharge time test
• During visual inspection the measuring ductor length. machine. The instrument trips out if the The following measurements and tests
• after upgrading or changing of ma-
chine; points for the electrical testing have to leakage current exceeds the predefined can be performed:
Functional test
• and during periodic retests of machine. be determined too. Before continuity measurement test limit. • Contact voltage,
Functional check explores if the ma-
leads compensation is required to elimi- • Trip-out time,
Check that there are no signs of: nate the influence of test leads resist- chine is working properly.
Verification of safety of machines • Trip-out current,
• Damage ance and instrument’s internal resist- Following items should be checked
According to IEC/EN 60204, Ed.5 verifi-
• Pollution, moisture, dirt that can jeop- ance. • RCD autotest. while the machine is operating:
cation of electrical safety of machines is
performed by inspection and measure- ardize safety • Temperature regulators, monitors;
ments: • Corrosion • RCDs and other disconnection devic-
• Inspection that the electrical equip- • Overheating es;
ment complies with its technical docu- HV withstanding test • Operation of functional disconnecting
mentation; Verification of protection against indirect devices;
• Verification of protection against indi- contact by automatic disconnection Components and devices that are not • Operation of switches, lamps, keys;
rect contact by automatic disconnec- This verification step is quite complex rated to withstand the test voltage shall • Rotating parts, motors, pumps;
tion; and must always be carryed out in some Continuity test be disconnected during the testing. Testing of RCD in RCD protected machine • Power consumption, etc.
Testing the safety of machines and switchboards Selection Guide for appliances, machines and switchboards testers
MEASUREMENTS
Withstanding test 1000 VAC
Withstanding test 1890 VAC −
Withstanding test 2500 VAC
Withstanding test 100 ... 5000 VAC (500 VA) − −
Continuity 100 mA − −
Continuity 200 mA
Continuity 10 A
Continuity 25 A − −
Voltage drop test 10 A −
Insulation resistance 250 VDC −
Insulation resistance 500 VDC
Insulation resistance 1000 VDC − −
Differential leakage current
Touch leakage current
Substitute leakage current
Discharge time
Leakage current measurement with optional clamp − −
RCD, PRCD testing − −
Line impedance − −
Loop impedance − −
Voltage measurement
Frequency measurement − −
Phase rotation indication − −
Polarity test (IEC lead test) − −
Functional (load) test
ADITIONAL FEATURES
PASS / FAIL evaluation
Mains supply autocheck
Graphical LCD
Graphical on-line help − −
Backlight −
Real time clock −
QWERTY keyboard − −
Auto testing (organizer, custom autotests) −
Barcode shortcut auto testing − −
Communication ports RS232 / USB / Option / / Option
“Test and tag” (barcode scanner + label printer) − −
Data download to PC
Project upload from PC to instrument − −
Trend (compare) on instrument’s LCD − −
Trend with PC SW PATLink PRO Plus −
Number of memory locations 1638 6000 62
STANDARD / OPTIONAL ACCESSORIES
Barcode scanner Option Option −
Label printer − Option −
Receipt printer Option Option −
PC SW PATLink PRO (download, report, data export) −
PC SW PATLink PRO Plus (download, PRO Plus report, data export, trend) − Option Option
PC SW CE Link (download, report, autosequence editor) Option − −
GENERAL DATA
Power supply 115 V / 230 V 115 V / 230 V 230 V
CE MultiTester integrated into the automated production line. Weight 13.5 kg 8.4 kg 9.5 kg
Dimensions (mm) 410 x 175 x 370 345 x 160 x 335 345 x 160 x 335
PATLink PRO and PATLink PRO Plus Full detailed PRO Report Full detailed PRO Plus Report
PC software PATLink PRO is an advanced, user friendly software package designed with the portable appliance testing
engineer in mind. The graphical interface with drag and drop data relocation, data filtering, data archiving functions and
automatic report generation allows a variety of users with a range of different skills and abilities to create professional
reports which include company logos. The PATLink PRO Plus software introduces extra features including the ability to
reload data onto Metrel uploadable / downloadable testers, perform trend analysis on equipment and introduces PRO
Plus certificates and individual appliance reports.
KEY FEATURES:
Full data filtering: All data can be fil-
tered by different parameters: Retest
Date, Test Date, Project, User, etc.
Tree style or table style: Data can be
represented in tree or table view.
Drag and drop: The elements of the
structure can be relocated and renamed.
Customer database: It allows test engi-
neer to create his own database of cus-
tomers fully equipped with all appropri-
ate data.
Company logo loading: Load company
logos into the software so that they can
be printed on test reports.
Data backup: All downloaded data can
be backed up to prevent the loss of valu-
able data for example in case of hard
disk failure.
Appliance information editing: Allows
you to edit data, e.g. to set up Retest
Date, Repair Code, add Comments, etc.
Export of test results: Data of selected
appliances together with test results can
be exported to other programs (MS Excel,
MS Word).
PDF report: Test Report can be trans- MI 3310); if needed any deviations can be The following Certificates for PRO
formed into PDF format. adjusted on the tester on site. Plus version are available:
Full built-in help files: Integrated help Trend analysis: Enables to compare test • METREL PRO Plus (Single) Electrical Trend analysis (comparison of results
menu contains detailed explanation of results of the last and previous tests.
PC SW handling. equipment test report; from tests performed in different time
Automatic PRO report generation:
Automatic self-test record keeping: Re- • METREL Full detailed PRO Electrical period)
Enables automatic generation of Test
sults of the CHECKBOX function (MI 3311 Report (standard or full detailed). equipment test report;
only) can be automatically transferred to PATLink PRO Plus professional reports: • METREL PAT PRO Plus Electrical
the PC and printed onto the test reports. The PRO Plus report displays results as equipment test report.
“Plug & Play”: When meter is connect- the PRO version but enables editing the
ed to the PC it is automatically recog- information before printing the report.
nized by the software. PASSWORD PROTECTION:
Upload data back to PAT tester: User PC SW PATLink PRO / PRO Plus is com-
can upload test results from the previ- PC SW PATLink PRO is password pro-
patible with:
ous measurement session (e.g. from last • MI 3321 MultiservicerXA tected for the following instrument:
year) so the same tests can be simply • MI 2170 Multiservicer • MI 3311
repeated and results of both measure- • MI 3305 OmegaPAT Plus PC SW PATLink PRO Plus is password
ments can be compared (MI 3321, MI • MI 3304 BetaPAT Plus protected for all Metrel PAT testers.
3305, MI 3304, MI 3310A, MI 3310). • MI 3310 / MI 3310A SigmaGT
Autosequences upload: Test autose- • MI 3309 Delta GT
quences can be prepared via PATLink • MI 3311 GammaGT ORDERING INFORMATION:
PRO and then sent to the tester (MI 3321,
MI 3305, MI 3304, MI 3310A, MI 3310, The following Certificates for PRO • A 1305 PC SW PATLink PRO with USB
and RS232-PS/2 cable Custom autotest sequence can be cre-
MI 3309, MI 3311) for testing speedup. version are available:
• A 1306 PC SW PATLink PRO Plus with ated on PC and then uploaded to the
Structures upload: The structure of test • Full detailed PRO Electrical equip-
USB and RS232-PS/2 cable instrument
site can be created in advance on the PC ment test report;
and then simply uploaded to the tester • METREL PAT PRO Electrical equip- • A 1203 Upgrade code PATLink PRO to
(MI 3321, MI 3305, MI 3304, MI 3310A, ment test report. PATLink PRO Plus
Selection Guide for PAT Accessories Selection Guide for PAT Accessories
MI 3310A
MI 3310A
MI 3305
MI 3304
MI 3310
MI 3309
MI 3311
MI 2142
MI 2094
MI 3321
MI 2170
MI 3305
MI 3304
MI 3310
MI 3309
MI 3311
MI 2142
MI 2094
MI 3321
MI 2170
A 1322
A 1322
Part Part
Photo Description Target application Photo Description Target application
number number
Euro Z 290 A is the impedance tester which 1-phase adapter 16 A, 1-phase test adapter for, testing of 1 phase exten-
A 1143 Euro Z 290 A enables line / loop impedance measurements – – – – – – – – – – A 1419 3 pin male / 16 A sion leads in combination with A 1322 / Active – – – – – – – – – –
with an accuracy down to 0.1 mΩ. Schuko female, 2 m 3-phase Adapter.
1-phase adapter 16 A, 1-phase test adapter for, testing of 1 phase exten- Continuity test lead Extension test leads with protection shield and
A 1418 3 pin female / 16 A sion leads in combination with A 1322 / Active – – – – – – – – – – S 1072 with crocodile clip, 2 x with crocodile clips for continuity testing with high – – – – – – – – – –
Schuko male, 2 m 3-phase Adapter. 2.5 m, 2 pcs test currents (10 A, 25 A).
Selection Guide for PAT Accessories Selection Guide for PAT Accessories
MI 3310A
MI 3310A
MI 3305
MI 3304
MI 3310
MI 3309
MI 3311
MI 2142
MI 2094
MI 3321
MI 2170
MI 3305
MI 3304
MI 3310
MI 3309
MI 3311
MI 2142
MI 2094
MI 3321
MI 2170
A 1322
A 1322
Part Part
Photo Description Target application Photo Description Target application
number number
The adapter equipped with CEE 16 A schuko plug Crocodile clip assures secure and permanent
Insulation / Subleak- supports insulation resistance and touch leakage A 1013 Crocodile clip, black contact during the measurement on bus bars, – –
A 1095 – – – – – – – – – –
age adapter current measurements on Class 1 portable appli- fixing screws, etc.
ances with conductive metal parts.
The adapter allows continuity and insulation re- Crocodile clip assures secure and permanent
Adapter for perma- A 1064 Crocodile clip, red contact during the measurement on bus bars, – – – – – – – –
A 1096 sistance measurement on permanently wired – – – – – – – – – –
nently wired loads fixing screws, etc.
loads (without plug).
Selection Guide for PAT Accessories Selection Guide for PAT Accessories
MI 3310A
MI 3310A
MI 3305
MI 3304
MI 3310
MI 3309
MI 3311
MI 2142
MI 2094
MI 3321
MI 2170
MI 3305
MI 3304
MI 3310
MI 3309
MI 3311
MI 2142
MI 2094
MI 3321
MI 2170
A 1322
A 1322
Part Part
Photo Description Target application Photo Description Target application
number number
Printer supports printing of identification labels Fast charger for 8 AA Fast battery charger for up to 8 pieces of AA re-
Label printer
A 1318 containing a complete appliance information and – – – – – – – – – – A 1160 batteries with a set of chargeable batteries, and a set of 6 pcs NiMH – – – – – – – – –
(Bluetooth)
PASS or FAIL evaluation of test results. 6 NiMH bat., type AA rechargeable batteries, type AA.
Fast charger for AA, Fast battery charger for up to 12 pcs AA, 6 pcs
A 1295 Spare label roll Spare label rolls for printer A 1276 and A 1318. – – – – A 1169 C, D and 9 V block C or D rechargeable batteries, 4 pcs 9 V block – – – – – – –
batteries batteries.
High quality spare label rolls for printer A 1276 Communication cable RS232 interface cable for connecting the instru-
A 1328 Hi-Q DT labels – – – – A 1017 – – – –
and A 1318. RS232 ment with the PC.
Paper for A 1276, Spare thermal receipt paper for printer A 1276 RS232 / USB adapter RS232 / USB adapter for instruments without
A 1379 – – – – A 1171 – – – – – – – –
A 1318 printers and A 1318. with 1 m cable USB comunication port.
Cleaning Kit for printers A 1276 and A 1318 PC SW CE Link is a multi-purpose software for pro-
Thermal printer clean- PC SW CE Link with
A 1359 which includes 25 Cleaning Cards and 25 Adhe- – – – – A 1073 gramming of the MI 2094, test data downloading – – – – – – – – – –
ing kit RS232 cable
sive Removers. and evaluation and creation of test reports.
Barcode labels, 1000 Appliances can be marked with barcode labels Small soft carrying Small soft carrying bag for transport and storage
A 1106 – – A 1271
pcs for easier identification. bag of test instrument or accessories.
MI 3310A
MI 3305
MI 3304
MI 3310
MI 3309
MI 3311
MI 2142
MI 2094
MI 3321
MI 2170
A 1322
Part
Photo
number
Description Target application Power Quality Analysis
LAN Cabling Certification
A 1303 Soft hand strap Soft hand strap for holding the instrument. – – – – – – – – – Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Voltage and Continuity Testers
Variable transformers /
Equipment for laboratories and Schools
GOOD TO KNOW
Power Quality Analysis 4 - 02
Selection Guide for Power Quality Analysers 4 - 04
Selection Guide for Clamps 4 - 06
MI 2792 PowerQ4 Plus NEW 4 - 08
MI 2592 PowerQ4 4 - 10
MI 2392 PowerQ Plus 4 - 12
MI 2492 PowerQ 4 - 14
MI 2130 VoltScanner 4 - 16
PC SOFTWARE
PowerView 4 - 18
Selection Guide for Accessories 4 - 20
Xtraordinarily Adaptable
MultiServicerXA:
Xtraordinary Abilities
We lead by XAmple
CATALOGUE 2012/13
Option – Not available
Find out more about modern power Energy Transients Power quality improvement
quality measurement techniques Energy is the generation or use of elec- Transient is a term for short, highly Prepare instrument Captured with Power Analyser data can
START
There are quite a few reasons for meas- tric power over a period of time. This damped momentary voltage or current for new measurement be used for improvement of supplied
before going to meas-
uring and analysing power quality nowa- is usually expressed in kilowatt-hours disturbance. They usually appear as a uring site. Check: power quality. There are different ways
days. Potential interactions between (kWh). consequence of external electromag- • Are time and date
to increase efficiency of power supply.
correct?
netic interferences (atmospheric electric
In Office
end use equipment and electric distribu- • Are batteries in good
tion system, external electromagnetic Fundamental frequency discharges, switching manoeuvres). Step 1:
condition?
Cutting power peaks
• Is the Memory
Instrument Setup
interferences, resonant states between The fundamental frequency is the low- • Set Time & Date
List empty? If it is One of the simplest and the most ef-
est and most predominant frequency in Flickers not, download all
ficient way to decrease the electricity
electrical circuits and some other factors • Recharge batteries data from previous
Flicker appears as changing illumination • Clear memory
power bill is by lowering peaks of con-
call for a need to be analysed in order a power system (e.g. the fundamental measurements and
intensity which is a reflection of a chang- Connection to 3-phase 3-wire system release storage for
that harmful consequences can be omit- frequency of the mains voltage in the EU new measurement. sumed power (peak demand). This can
ing voltage level.
ted or prevented. is 50 Hz). The fundamental frequency is be achieved by:
Power quality analysing includes meas- also called the 1st harmonic of the sys- Inrush current • reorganization of production processes;
urements of: tem. As a motor begins the current needed to Step 2: Setup instrument ac- • embedded generation.
Measurement Setup cording to the meas-
• Phase to ground voltages; start the motor can be 10 to 15 times the urement point nominal
• Phase to neutral voltages; Voltage events normal operating current. This initial surge Step 2.1: voltage, currents, load The first solution can be implemented
Sync. & wiring
• Neutral to ground voltages; Dips of current can cause dips in voltage and • Conn.Type
type. Optionally en- in systems where some tasks can be
able events or alarms
• Phase to phase voltages in three- Supply voltage dip represents tem- can be hard to analyse with normal test (4W,3W,1W) and define parameter stopped or rescheduled.
• Sync channel
phase systems; porary drops of the voltage under the instruments, for this reason an analyser U1I1IU12
thresholds. The second solution can be implemented
• Phase currents; nominal level. with a fast logging function is required. in systems with generators that are often
• Current in a neutral conductor; used as a back-up power supply.
Step 2.2:
Swells Instrument connection to the LV and Both solutions require additional moni-
• Frequency; Connection to 3-phase 4-wire system Voltage range & ratio
Supply voltage swells are instantaneous MV Power Systems • Voltage range toring and control systems that are de-
• Power Factor, cos ϕ; Step 3:
voltage increases (opposite to dips). When connecting the instrument it is • Voltage ratio Inspection signed upon previously conducted meas-
• Harmonic components of current and essential that both current and voltage • Phase diagram
urement and analysis of the situation in
voltage and their direction; connections are correct. In particular the
• U,I,f meter screen
Interruptions • Power meter screen the field. Another possibility to increase
• Waveform of current and voltage at following rules have to be observed:
Voltage interruption is classified as a Step 2.3: efficiency is by increasing the power fac-
specific circumstances (peak magni- Clamps setup
network’s isolation from any source of • Clamp type tor using corrective techniques.
tude, primary frequency, time of oc- Current clamp-on current transformers • Clamp ratio
supply.
currence, rising rate); • The arrow marked on the clamp-on
Double check Meas- Capacitor Banks
• Transients. current transformer has to point in the
On Measuring site
Unbalance urement setup using Capacitor banks are the devices most sus-
direction of current flow, from supply Phase diagram, and
Supply voltage unbalance arises when to load;
Step 2.4: (Optional)
various scope and me- ceptible to the presence of harmonics.
Active Power (P) Event Setup
rms values or phase angles between • If the clamp-on current transformer is • Nominal voltage tering screens. Since consumer’s loads usually have in-
Active power is the power generated if a • Thresholds Using power meter
consecutive phases are not equal. connected in reverse the measured check if power is ductive characteristics, capacitor banks
voltage is placed over a purely resistive flowing in right direc- are used for compensation of inductive
load and current is allowed to flow. Ac- power in that phase would normally Connecting instrument to the existing current transformers tion (power should be
Harmonics appear negative. in medium voltage system positive for load and currents. This feature allows:
tive power is usually measured in watts Harmonics are integer frequency multi- Step 2.5: (Optional) negative for generator • better overall system performance;
(W) or kilowatts (kW). plication of the fundamental frequency
Alarm Setup measurements).
• increasing availability of active power;
Phase relationships Recommended Recording Practice • Define alarm and
(e.g. with a fundamental of 50 Hz, the 2nd • The clamp-on current transformer Power quality measurements are spe-
its parameters • decreasing transmission loses;
Reactive Power (Q) harmonic is 50 x 2 = 100 Hz, 3rd harmon- connected to current input connector • increasing voltage;
Reactive power is the power that is cific type of measurements, which can
ic is 50 x 3 = 150 Hz). Harmonics can be I1 has to measure the current in the • decreasing financial penalty because
generated by reactive components (e.g. last several days or even up to several
caused by a variety of modern day equip- phase line to which the voltage probe Step 5: (Optional)
of poor power factor.
inductors, capacitors) to create a mag- weeks. Usually recording campaign is Step 4: Recorder setup
ment including resonating transformers, from L1 is connected. On Line Measurement • Select signals for
netic field. This is usually measured in performed to: • Perform measure- recording
switch-mode power supplies, IT equip- ment EN 50160 Standard Overview
Volt-Ampers reactive (VAr). In case of events capturing, it is recom- • Statistically analyze some point in the • Define recording
ment, etc. • Save waveform start time, duration EN 50160 is one of the most important
mended to connect unused voltage in- network. snapshots and interval
Start standards in field of power quality which
Apparent Power (S) puts to N voltage input. • Troubleshoot malfunctioning device or recording
Interharmonics defines, describes and specifies the
Apparent power is the perceived power Interharmonics are harmonics that are machine. Step 6:
main characteristics of the voltage at a
Measurement conclusion
from a load that has both resistive and not an integer multiplication of the fun- • Stop recorder network user’s supply terminals in public
reactive components. Apparent power damental frequency. The main sources Mostly long-term measurements are • Power off instrument
low voltage and medium voltage distri-
• Remove wiring
is the vector sum of both active and re- of interharmonic waveform distortion performed only once, so why it is very • Analyze recorder data with instrument bution networks under normal operating
active power and is usually measured in are static frequency converters, induc- important to properly set measuring (Memory list, Event and Alarm tables)
conditions. This standard describes the
Volt-Amperes (VA). tion motors and arcing devices. equipment. Measuring with wrong set- limits or values within which the volt-
ting can lead to false or useless meas- Step 7: age characteristics can be expected to
Power Factor urement results. In the following flow
In Office
Total Harmonic Distortion (THD) Report generation (PowerView) remain over the whole of the public dis-
• Download data
Power factor is a measure of a power THD is the ratio of a wave’s harmonic chart recommended recorder procedure • Analyse data tribution network and does not describe
system’s efficiency and is the ratio of content (for voltage or current) to its fun- is shown (with MI 2792 PowerQ4 Plus • Export to Excel or Word the average situation usually experi-
real power to apparent power. damental component. Connection to 1-phase 3-wire system instrument). enced by an individual network user.
Selection Guide for Power Quality Analysers Selection Guide for Power Quality Analysers
INPUTS
Number of current measuring inputs 4 4 3 3 −
Number of voltage measuring inputs 4 4 3 3 1
MEASUREMENTS
TRMS Current measurement (Min., Max., Avg.) −
TRMS Voltage measurement (Min., Max., Avg.) (rms only)
Scope function −
On-line harmonics measurement −
Frequency measurement
Power measurement (W, VA, VAr) −
THD and harmonics analysis −
Interharmonics analysis − − − −
Power Factor and cos ϕ −
Registration of voltage events (sags, swells,
−
interruptions)
Statistical evaluation − − − −
Current in neutral conductor calculated value calculated value −
Phase diagram −
Unbalance −
(without flicker 1-phase, without flicker
EN 50160 Analysis −
measurement) measurement
Flicker measurement − − −
Transients measurement − − − 1-phase, voltage transients
Waveform recording (snapshot) (snapshot) (snapshot) −
Inrush currents − −
Energy measurement −
Signalling − − − −
Temperature measurement − − − −
Integration period 1 ... 3600 s 1 ... 3600 s 1 ... 1800 s 1 ... 1800 s 1 ... 1260 s
COMMUNICATION PORTS
USB Option
RS232
GPS time sinhronisation − − − −
Remote instruments control (GPRS) − − − −
GENERAL
Graphical LCD with backlight 320 x 200 dots 320 x 200 dots 160 x 160 dots 160 x 160 dots −
On-site analysis of recorded data −
Built-in power supply for flexible clamps −
Maximal recording time 4 ... 8 weeks 4 ... 8 weeks 2 ... 5 days 3 days 2 ... 4 weeks
Memory module size 8 MB 8 MB 1 MB 1 MB 32 kB
PC Sofware
Maximal test voltage – interphase value 1730 V rms 1730 V rms 952 V rms 952 V rms 265 V rms
Maximal test voltage – between phase
1000 V rms 1000 V rms 550 V rms 550 V rms 265 V rms
and PE conductors
Frequency range 10 ... 70 Hz 10 ... 70 Hz 45 ... 66 Hz 45 ... 66 Hz 47 ... 62 Hz
CAT IV / 600 V CAT IV / 600 V
Over voltage category CAT III / 600 V CAT III / 600 V CAT III / 300 V
CAT III / 1000 V CAT III / 1000 V
AC power supply
Built-in battery charger
Rechargeable batteries (NiMH) 6 x AA 6 x AA 6 x AA 6 x AA 4 x AA
Battery life (tipically) 15 h 15 h 12 h 12 h 180 h
Weight 0.65 kg 0.65 kg 0.65 kg 0.65 kg 0.51 kg
Dimensions (mm) 220 x 115 x 90 220 x 115 x 90 220 x 115 x 90 220 x 115 x 90 103 x 51 x 199
A 1281
5A 0.5 A ... 10 A ± 0,5 % CAT III / 600 V;
0.5/5/100/1000 A current and power measure- * * Iron 52 mm < 0.5° ± 1.5 % < 1.5°
100 A 10 A ... 175 A ± 0,5 % IP 20
/1V ments including leakage current
1000 A 100 A ... 1200 A ± 1,2 %
measurement.
High accuracy current clamp
1000 A / 1 V with jaw opening
A 1033
A 1033
Current clamp 1000 A 50 A ... 1200 A ±2% CAT III / 600 V;
− 52 mm and fixed 1.5 m cable for Iron 52 mm < 2° ± 3.5 % < 3°
1000 A / 1 V 100 A 5 A ... 200 A* ±3% IP 20
power measurements with Met-
rel power quality analysers.
Mini current clamp 5 A / 1 V with
Mini current
A 1122
A 1122
jaw opening 15 mm for power 5A 250 mA ... 10 A ±2% CAT III / 600 V;
− clamp Iron 15 mm < 6° ±3% < 6°
measurements. Requires A 1039 0.5 A 25 mA ... 1 A* ±2% IP 20
5A/1V
connection cable.
A 1069
with jaw opening 15 mm for 100 A 5 A ... 200 A ±2% CAT III / 600 V;
− clamp Iron 15 mm < 3° ±3% < 2°
power measurements. Requires 10 A 500 mA ... 20 A* ±2% IP 20
100 A / 1 V
A 1039 connection cable.
Single phase flexible current clamp
1-phase flexible
with three selectable measuring 30 A 3 A ... 60 A ±1%
A 1227
A 1227
current clamp CAT III / 600 V;
ranges. Does not require external * * Flex φ 14 cm 300A 10 A ... 600 A ±1% < 1° ±3% < 10°
3000/300/30 A IP 64
power supply as it is powered by 3000 A 60 A ... 6000 A ±1%
/1V
the measuring instrument.
3-phase flexible 3-phase flexible current clamp
30 A 3 A ... 60 A ±1%
A 1257
A 1257
current clamp with three selectable measuring CAT III / 600 V;
− Flex φ 14 cm 300 A 10 A ... 600 A ±1% < 1° ±3% < 10°
3000/300/30 A ranges. Powered by alkaline or IP 64
3000 A 60 A ... 6000 A ±1%
/1V rechargeable batteries.
Single phase flexible current
1-phase flexible
clamp with three selectable 30 A 3 A ... 60 A ±1%
A 1287
A 1287
current clamp CAT III / 600 V;
− measuring ranges. Powered by Flex φ 14 cm 300 A 10 A ... 600 A ±1% < 1° ±3% < 10°
3000/300/30 A IP 64
alkaline or rechargeable batter- 3000 A 60 A ... 6000 A ±1%
/1V
ies.
3-phase flexible 3-phase flexible current clamp
20 A 2 A ... 40 A ±1%
A 1179
A 1179
current clamp with three selectable measuring CAT III / 600 V;
− Flex φ 14 cm 200 A 7 A ... 400 A ±1% < 1° ±3% < 10°
2000/200/20 A ranges. Powered by alkaline or IP 64
2000 A 40 A ... 4000 A ±1%
/1V rechargeable batteries.
A 1037
measurements on distribution 0.5 A 10 mA ... 1 A ±0,3 % CAT III / 600 V;
− transformer Iron N/A < 0.5° ±1% < 1.0°
panels with 5 A nominal output 5A 0.5 A ... 10 A* ±0,3 % IP 40
5A/1V
current.
*MI 2492, MI 2392 supported from HW4 / FW9.2 *Range is available only on PowerQ series instruments: MI 2492, MI 2392, MI 2592 and MI 2792
Function
AC Voltage inputs
The MI 2792 PowerQ4 Plus is a power quality analyser specially designed for troubleshooting of power systems and de- Number of inputs 4
vices. Rugged design, long battery autonomy (up to 15 hours), powerful recorders, events and alarms capture, flex current Input voltage range 20 … 1500 Vrms L - N (20 … 2600 Vrms L - L)
Basic accuracy 0.2% of reading
clamps as standard accessory, remote instrument control via optional GPRS modem, ability to synchronize instruments via Resolution 10 mV, 100 mV
GPS make this instrument unique troubleshooting tool. Advanced PC SW package PowerView2 enables detailed analysis Sampling rate 1024 samples per 10 periods
Frequency range 10 … 70 Hz
of recorded data and automatic creation of professional test report. Excellent price / performance ratio, small size, ad-
AC Current inputs
vanced measurement methods and loggers are undoubted highlights of the MI 2792. Number of inputs 4
Input voltage range 20.0 mVrms … 2 Vrms
Current measuring range 3 … 6000 A (for current clamp A 1227)
Resolution 0.1 mV (0.1 A for current clamp A 1227)
MEASURING FUNCTIONS: Basic accuracy 0.25 % of reading
Sampling rate 1024 samples per 10 periods
• Voltage: TRMS, peak, crest factor Function Measuring range Resolution Accuracy
(4-channel); Frequency 10.00 … 70.00 Hz 2 mHz ±10 mHz
• Current: TRMS, peak, crest factor Power (W, VA, VAR) 0.000 k … 9.999 M 4 digits ±0.5 % of reading
(4-channel); Power factor -1.00 … 1.00 0.01 ±0.02
• Power (active, reactive, apparent); cos ϕ 0.00 … 1.00 0.01 ±0.02
• Power factor, cos ϕ; UhN < 3 %·Unom 10 mV ±0.15 %·Unom
• Unbalance, flicker measurement; Harmonics analysis up 50th component 3 %·Unom < UhN < 20 %·Unom 10 mV ±5 %·UhN
IhN < 10 %·IN 10 mV ±0.15 %·IN
• Harmonic and interharmonic analysis up 10 %·IN < IhN < 100 %·IN 10 mV ±5 %·IhN
to 50th harmonics, THD measurement; 0 %·Unom < THDU < 20 %·Unom 0.1% ±0.3
• Energy (active, reactive, generated, THD 0 %·IN < THDI < 100 %·IN 0.1% ±0.6
consumed); 100·% IN < THDI < 200 %·IN 0.1% ±1.5
• Capturing and recording of power sup- Signalling 1 %·UN < USig < 3 %·UN 10 mV ±0.15 %·UN
3 %·UN < USig < 20 %·UN 10 mV ±5 %·USig
ply events (shutdowns, interruptions, Voltage dips and swells
swells, dips); Magnitude 20 … 1500 V 10 mV, 100 mV 0.5 % of reading
• Inrush currents monitoring and recording; Duration 30 ms … 7 days 1 ms ±20 ms
• Waveform displaying, snapshot and -20 °C ... -10 °C 0.1 °C ±2.0 °C
Temperature -10 °C ... +85 °C 0.1 °C ±0.5 °C
recording; +85 °C ... +125 °C 0.1 °C ±2.0 °C
• Transients recording; Recording
• Power quality analysis according to EN Records up to 524 parameters (min, max, avg)
50160; General recorder Duration: 1 sec ... 99 days
Integration interval: 1 sec ... 60 min
• Recording up to 10 adjustable alarms; Trigger: Manual, Time
• Temperature measurement. Records up to 8 parameters (U1 ... UN, I1 ... IN)
Waveform recorder Duration: 1 cycle period up to 3770 cycle periods
Sampling: 5120 samples / sec (for 50 Hz signals)
Trigger: Manual, Event or Alarm Table
KEY FEATURES: Records up to 8 parameters (U1 ... UN, I1 ... IN)
Inrush / Fast recorder Duration: 1 sec ... 3 min
• 4 voltage channels with wide meas- Sampling: 1 reading per half-cycle up to 1 reading per 10-cycle
urement range: 0 ... 1000 Vrms (CAT Trigger: Manual, Current or Voltage Threshold
III / 1000 V). Record up to 8 parameters (U1 ... UN, I1 ... IN)
• 4 current channels with support for Transient recorder Duration: up to 47 periods
Sampling: 51200 samples / sec (for 50 Hz signals)
automatic clamp recognition and “on Trigger: Manual, Voltage Envelope (dV)
instrument“ range selection. COM port RS232 and USB
• Compliance with power quality stand- • Temperature probe for measurement • Harmonics spectrum analysis for se- Display Graphic LCD with backlight, 320 x 200 dots
ard IEC 61000-4-30 Class S/A. of the temperature of the tested trans- lection of harmonic filters; Memory module 8 MB Flash
• Power measurements compliance with former, capacitor bank, etc. • UPS, voltage generators and regula- Voltage supply 230 VAC or 6 x 1.2 V NiMH rechargeable batteries, type AA
IEC 61557-12 and IEEE 1448 standards. Over voltage category CAT III / 1000 V; CAT IV / 600 V
• Possibility of remote control of the in- tors checking and troubleshooting;
• Complete power quality analysis ac- Protection class Double insulation
strument or group of them via GPRS • Voltage, current, power monitoring Dimensions 220 x 115 x 90 mm
cording to EN 50160 including signal- modem. and recording; Weight 0.65 kg
ling and interharmonics. • Flexible clamps (without additional power • Consumption profile recording.
• Capture of voltage events and user de- supply) are included in the standard set.
fined alarms. • 15 hours of autonomous (battery) supply.
• 4-quadrant measurements (generator STANDARDS: STANDARD SET:
• Powerful PC SW PowerView2 enables
and load with capacitive or inductive downloading, view, analysis of recorded
character). Functionality: MI 2792 • Voltage measurement lead, black
data and professional report creation. IEC/EN 61000-4-30, Class S;
• Up to 524 parameters can be moni- • Instrument PowerQ4 Plus • Voltage measurement lead, green
tored or recorded simultaneously. IEC/EN 61557-12; • 1-phase flexible current clamps 3000 / 300 • Temperature probe
• 8 MB of internal memory space allows IEC/EN 61000-4-7, Class II; / 30 A (A 1227), 4 pcs • PC SW PowerView2
APPLICATION: • Test probe, red, 2 pcs
recording over 4 weeks. IEC/EN 61000-4-15; • RS232 and USB cables
• Power quality assessment and trou- EN 50160; IEEE 1448 • Test probe (CAT II), red, 3 pcs
• Powerful troubleshooting tools: transient, • Power supply adapter
• Test probe (CAT II), black
inrush / fast and waveform recording. bleshooting in low and middle voltage Electromagnetic compatibility: • Crocodile clip, black • 1.2 V NiMH rechargeable battery, 6 pcs
• On-screen displaying of trends and electrical systems; EN 61326 • Crocodile clip, green • Soft carrying bag
captured events and simultaneous re- • Checking power correction equipment Safety: • Crocodile clip, red, 3 pcs • Instruction manual
cording in the background. performance; EN 61010-1 • Voltage measurement lead, red, 3 pcs • Calibration certificate
Function
The MI 2592 PowerQ4 is a handheld, simple to use, portable power quality analyser with four current and four voltage AC Voltage inputs
measuring channels. Integrated in rugged housing and packed with powerful functions it can be effectively used for Number of inputs 4
Input voltage range 20 … 1500 Vrms L - N (20 … 2600 Vrms L - L)
monitoring, troubleshooting and analysing of power quality conditions in power distribution networks either in industry
Basic accuracy 0.2 % of reading
or utilities. The PowerQ4 is the first handheld power quality analyser which is compliant with power quality standard IEC Resolution 10 mV, 100 mV
61000-4-30 Class S and standard IEC 61557-12. Powerful PC Software package PowerView comes delivered as part of a Sampling rate 1024 samples per 10 periods
standard set and enables downloading, analysing of recorded data and creation of test reports. Trough a simple but pow- Frequency range 10 … 70 Hz
erful interface PowerView helps to find recorded data quickly and allows to make complex analysis and data comparison. AC Current inputs
Number of inputs 4
Input voltage range 20.0 mVrms … 2 Vrms
Current measuring range 3 … 6000 A (for current clamp A 1227)
MEASURING FUNCTIONS: Resolution 0.1 mV (0.1 A for current clamp A 1227)
• Voltage: TRMS, peak, crest factor Basic accuracy 0.25 % of reading
Sampling rate 1024 samples per 10 periods
(4-channel);
Function Measuring range Resolution Accuracy
• Current: TRMS, peak, crest factor
(4-channel); Frequency 10.00 … 70.00 Hz 2 mHz ±10 mHz
• Power (active, reactive, apparent); Power (W, VA, VAR) 0.000 k … 9.999 M 4 digits ±0.5 % of reading
• Power factor, cos ϕ; Power factor -1.00 … 1.00 0.01 ±0.02
• Unbalance, flicker measurement; cos ϕ 0.00 … 1.00 0.01 ±0.02
• Harmonic analysis up to 50th harmon- UhN < 3 % Unom 10 mV 0.15 %·Unom
ics, THD measurement; 3 % Unom < UhN < 20 % Unom 10 mV 5 %·UhN
• Energy (active, reactive, generated, Harmonics analysis up 50th component
consumed); IhN < 10 % IN 10 mV 0.15 %·IN
• Capturing and recording of power sup- 10 % IN < IhN < 100 % IN 10 mV 5 %·IhN
ply events (shutdowns, interruptions, 0 % Unom < THDU < 20 % Unom 0.1% ±0.3
swells, dips); THD
0 % IN < THDI < 100 % IN 0.1% ±0.6
• Inrush currents monitoring and recording;
100 % IN < THDI < 200 % IN 0.1% ±1.5
• Waveform displaying and snapshot;
Voltage dips and swells
• Power quality analysis according to EN
Magnitude 20 … 1500 V 10 mV, 100 mV 0.5 % of reading
50160; Duration 30 ms … 7 days 1 ms ±20 ms
• Recording up to 10 adjustable alarms.
Recording
Integration interval 1 … 3600 s
Maximum number of signals 509
KEY FEATURES:
COM port RS232 and USB
• 4 voltage channels with wide meas- Display Graphic LCD with backlight, 320 x 200 dots
urement range: 0 ... 1000 Vrms (CAT
Memory module 8 MB Flash
III / 1000 V).
Voltage supply 230 VAC or 6 x 1.2 V NiMH rechargeable batteries, type AA
• 4 current channels with support for au-
tomatic clamp recognition. Over voltage category CAT III / 1000 V; CAT IV / 600 V
• Compliance with power quality stand- Protection class Double insulation
• On-screen displaying of trends and • Checking power correction equipment
ard IEC 61000-4-30 Class S. Dimensions 220 x 115 x 90 mm
captured events and simultaneous re- performance;
• Power measurements compliance with Weight 0.65 kg
cording in the background. • Harmonics spectrum analysis for se-
IEC 61557-12 and IEEE 1448 standards.
• Flexible clamps (without additional sup- lection of harmonic filters;
• Simultaneous measurement and re-
ply) are included in the standard set. • UPS, voltage generators and regula-
cording of basic power quality param-
• Simultaneous 8 channels - 16 bit AD tors checking and troubleshooting;
eters (U, I, P, Q, S, PF, cos ϕ, THD).
conversion for accurate power meas- • Voltage, current, power monitoring STANDARD SET:
• Power quality analysis according to EN
50160 including flicker measurement urements (minimal phase shift error) and recording;
and standardized report printout in • 15 hours of autonomous (battery) supply. • Consumption profile recording.
MI 2592 • PC SW PowerView
graphic and table form. • Powerful PC SW PowerView enables • Instrument PowerQ4 • RS232 and USB cables
• 4-quadrant measurements (generator downloading, view, analysis of record- • 1-phase flexible current clamps 3000 / 300 • Power supply adapter
ed data and professional report crea- STANDARDS: • 1.2 V NiMH rechargeable battery, 6 pcs
and load with capacitive or inductive / 30 A (A 1227), 4 pcs
character). tion. Functionality: IEC/EN 61000-4-30, • Test probe, red, 3 pcs • Soft carrying bag
• Test probe, black, green • Instruction manual
• Up to 509 parameters can be moni- Class S; IEC/EN 61557-12; IEC/EN
• Crocodile clip, black, green • Calibration certificate
tored or recorded simultaneously. 61000-4-7, Class II; IEC/EN 61000-4-15;
APPLICATION: • Crocodile clip, red, 3 pcs
• 8 MB of internal memory space allows EN 50160; IEEE 1448
• Voltage measurement lead, red, 3 pcs
recording over 4 weeks. • Power quality assessment and trou- Electromagnetic compatibility: • Voltage measurement lead, black, green
• On-line Scope, Trend and Metering bleshooting in low and middle voltage EN 61326
modes. electrical systems; Safety: EN 61010-1
Function
The MI 2392 PowerQ Plus is a portable multifunction instrument for measurement and analysis of three-phase power sys- AC Voltage inputs
tems. Due to the small dimensions and user friendly interface of the MI 2392 PowerQ Plus it is ideally suited for routine or Number of inputs 3
Input voltage range 3.0 … 550.0 Vrms L - N (952.0 Vrms L - L)
complex power quality assessment, while a rugged case allows to use it in heavy duty industrial environments. Pre-set
Basic accuracy ± (1 % of reading + 0.5 V)
measuring profiles allow on-site evaluation of all major power quality parameters (U, I, P, Q, S, PF, cos ϕ, THD, individual Resolution 0.1 V
harmonic components, etc.) even without using a PC. Built-in memory module ensures up to five days of recording. New Sampling rate 1024 samples per 10 periods
powerful PC Software package PowerView comes delivered as part of a standard set and enables downloading, complex AC Current inputs
analysing and comparison of recorded data and creation of test reports. Number of inputs 3
Input voltage range 0.04 … 1 Vrms
Current measuring range 4 … 100 A and 40 … 1000 A (with current clamp A 1033)
Resolution 0.1 A
MEASURING FUNCTIONS: Basic accuracy ± (2 % of reading + 0.3 A)
Sampling rate 1024 samples per 10 periods
• TRMS voltage;
Function Measuring range Resolution Accuracy
• TRMS current;
• Power (active, reactive, apparent); Frequency 45.00 … 66.00 Hz 10 mHz ± (0.5 % of reading + 0.02 Hz)
• Power factor, cos ϕ; 0.000 … 0.999 k 1
0.00 … 9.99 k 10
• Energy (active, reactive, generated,
0.0 … 999.9 k 100
consumed); 0.000 … 9.999 M 1k
• Power quality analysis according to EN Power (W, VA, VAR) ± (3 % of reading + 3 digits)
0.00 … 99.99 M 10 k
50160; 0.0 … 999.9 M 100 k
• Harmonic analysis up to 50th harmon- 0.000 … 9.999 G 1M
0.00 … 40.00 G 10 M
ics, THD measurement;
• Capturing and recording of power sup- 0.00 … 0.39 0.01 ± 0.06
Power factor, cos ϕ
0.40 … 1.00 0.01 ± 0.03
ply events (shut-down’s, interruptions,
UM > 3 % UN (IM > 3 % IN) 0.1 % 5 % UM (IM) (3 % for DC)
swells, dips); Harmonics analysis up 50th component
UM < 3 % UN (IM < 3 % IN) 0.1 % 0.15 % UN (IN)
• Phase diagram and unbalance;
Recording
• Inrush currents monitoring and record- Integration period (IP) 1 … 1800 s
ing. Maximum number of signals 6
COM port RS232 and USB
Display Graphic LCD with backlight, 160 x 160 dots
KEY FEATURES: Memory module 1 MB Flash
Voltage supply 230 VAC or 6 x 1.2 V NiMH rechargeable batteries, type AA
• Three current and three voltage in-
Overvoltage category CAT III / 600 V
puts.
Protection class Double insulation
• Measurement and recording of basic
Dimensions 220 x 115 x 90 mm
power quality parameters (U, I, P, Q, S,
PF, cos ϕ, THD). Weight 0.65 kg
• Power quality analysis according to EN
50160 including standardized report
printout.
• 4-quadrant measurements (generator APPLICATION: STANDARDS: STANDARD SET:
and load with capacitive or inductive
character). • Power quality assessment and trou- Functionality:
bleshooting in low and middle voltage EN 50160; MI 2392 • Power supply adapter
• Quick set-up functions. • Instrument PowerQ Plus
IEC/EN 61000-4-30, Class B • 1.2 V NiMH rechargeable battery, 6 pcs
• On-line scope and metering modes. electrical systems; • Current clamp 1000 A / 1 V, 3 pcs • Soft carrying bag
• Voltage unbalance calculation for 3- • Balancing phase loads in 3-phase sys- • Test probe, red, 3 pcs • Instruction manual
tems; Electromagnetic compatibility:
phase systems. • Test probe, black • Calibration certificate
• Checking power correction equipment IEC/EN 61326-1 • Crocodile clip, black MI 2392F
• Recording of anomalies and inrush cur-
rents via adjustable triggers. performance; • Crocodile clip, red, 3 pcs • MI 2392
Safety: • Voltage measurement lead, 4 pcs • Current clamp 1000 A (A 1033), 3 pcs,
• Lightweight design. • Harmonics spectrum analysis for se-
IEC/EN 61010-1 • PC SW PowerView with RS232 and USB replaced by 1-phase flexible current clamp
• Large LCD display enables on-line lection of harmonic filters; cable 3000 / 300 / 30 A (A 1227), 3 pcs.
monitoring of measuring results either • Motor’s inrush currents monitoring MI 2392F
in table or graphic form. and recording for in-depth analysis of
• PC SW PowerView included in the a machines start-up or shut-down ef-
standard set is used for downloading, fects on a power network;
management of recorded data and • Voltage fluctuation recording;
creation of test reports. • Consumption recording.
Function
The MI 2492 PowerQ is a lightweight, handheld, 3-phase analyser for quick power quality assessment in low and middle AC Voltage inputs
voltage systems. All major power quality parameters like U, I, P, Q, S, PF, cos ϕ, THD, individual harmonic components can Number of inputs 3
Input voltage range 3.0 … 550.0 Vrms L - N (952.0 Vrms L - L)
be measured, recorded or monitored on-line. Thanks to various pre-set measuring profiles different diagnostics can be
Basic accuracy ± (1 % of reading + 0.5 V)
performed on-site even without using a PC. The MI 2492 PowerQ is built into a rugged case which allows to use it in harsh Resolution 0.1 V
industrial conditions. Built-in memory module ensures up to five days of recording. New powerful PC Software package Sampling rate 1024 samples per 10 periods
PowerView comes delivered as part of a standard set and enables downloading, complex analysing and comparison of AC Current inputs
recorded data and creation of test reports. Number of inputs 3
Input voltage range 0.04 … 1 Vrms
Current measuring range 4 … 100 A and 40 … 1000 A (with current clamp A 1033)
Resolution 0.1 A
MEASURING FUNCTIONS: Basic accuracy ± (2 % of reading + 0.3 A)
Sampling rate 1024 samples per 10 periods
• TRMS voltage; Function Measuring range Resolution Accuracy
• TRMS current; Frequency 45.00 … 66.00 Hz 10 mHz ± (0.5 % of reading + 0.02 Hz)
• Power (active, reactive, apparent); 0.000 … 0.999 k 1
• Power factor, cos ϕ; 0.00 … 9.99 k 10
• Energy (active, reactive, generated, 0.0 … 999.9 k 100
consumed); 0.000 … 9.999 M 1k
Power (W, VA, VAR) ± (3 % of reading + 3 digits)
• Harmonic analysis up to 50th harmon- 0.00 … 99.99 M 10 k
ics, THD measurement; 0.0 … 999.9 M 100 k
• Phase diagram and unbalance; 0.000 … 9.999 G 1M
0.00 … 40.00 G 10 M
• Oscilloscope mode.
0.00 … 0.39 0.01 ± 0.06
Power factor, cos ϕ
0.40 … 1.00 0.01 ± 0.03
KEY FEATURES: Harmonics analysis up 50th component
UM > 3 % UN (IM > 3 % IN) 0.1 % 5 % UM (IM) (3 % for DC)
UM < 3 % UN (IM < 3 % IN) 0.1 % 0.15 % UN (IN)
• Three current and three voltage inputs.
Recording
• Measurement and recording of basic Integration period (IP) 1 … 1800 s
power quality parameters (U, I, P, Q, S, Maximum number of signals 6
PF, cos ϕ, THD). COM port RS232 and USB
• 4-quadrant measurements (generator
Display Graphic LCD with backlight, 160 x 160 dots
and load with capacitive or inductive
Memory module 1 MB Flash
character).
• Harmonics analysis up to 50th compo- Voltage supply 230 VAC or 6 x 1.2 V NiMH rechargeable batteries, type AA
nent. Overvoltage category CAT III / 600 V
• Quick set-up functions. Protection class Double insulation
• On-line scope and metering modes. Dimensions 220 x 115 x 90 mm
• Voltage unbalance calculation for 3- Weight 0.65 kg
phase systems.
• Lightweight design.
• Large LCD display enables on-line
monitoring of measuring results either
in table or graphic form. STANDARD SET:
• PC SW PowerView included in the
standard set is used for downloading, MI 2492 • Power supply adapter
management of recorded data and • Instrument PowerQ • 1.2 V NiMH rechargeable battery, 6 pcs
creation of test reports. STANDARDS: • Current clamp 1000 A / 1 V, 3 pcs • Soft carrying bag
• Test probe, red, 3 pcs • Instruction manual
• Test probe, black • Calibration certificate
APPLICATION: Functionality: • Crocodile clip, black MI 2492F
EN 50160; • Crocodile clip, red, 3 pcs • MI 2492
• Power quality assessment and trou- • Voltage measurement lead, 4 pcs • Current clamp 1000 A (A 1033), 3 pcs, re-
bleshooting in low and middle voltage IEC/EN 61000-4-30, Class B
• PC SW PowerView with RS232 and USB placed by 1-phase flexible current clamps
electric systems; cable 3000 / 300 / 30 A (A 1227), 3 pcs.
• Power correction equipment perfor- Electromagnetic compatibility:
MI 2492F
The MI 2130 VoltScanner is a 1-phase voltage recorder for testing supply voltage on a socket in accordance with EN 50160 MI 2230 VAFMeter is handheld multifunction instrument which can accurately measure voltage, current, power, harmonic
power quality standard. Recording up to four weeks is possible and up to 3500 events can be stored into the instrument’s distortion and phase angles in single, two and three phase systems.
memory. The instrument can be easily set up via the ScanLink software and then sent out to customers who can simply
plug in the instrument for the definite period of time and then send it back for analysis. MS Windows compatible PC
Software ScanLink supports programming of the instrument, downloading of recorded data and creation of test reports. MEASURING FUNCTIONS:
Transfer of recorded data to other MS programs (e.g. Excel, Word, etc.) is possible as well. • TRMS Two channel voltage measure-
ments, up to 600 Vac;
MEASURING FUNCTIONS: • TRMS Two channel current measure-
ments, up to 3000 Aac;
• Recording of voltage events (dips, • U-U, I-I, U-I angle measurement, phase
swells, interruptions); diagram;
• Recording of frequency variations; • Support for three-phase (Aaron) sys-
• Recording of transient overvoltages; tems;
• Power quality analysis according to EN • Active, reactive and apparent power,
50160. PF, cos ϕ, THD, frequency;
• Continuity / resistance of conductors
with 200 mA test current with polarity
KEY FEATURES: change and with pass/fail functional-
• The parameters of the measurement ity.
are set up via PC SW ScanLink.
• Recording up to 4 weeks is possible. • Crocodile clip, 4 pcs
KEY FEATURES: STANDARDS:
• Voltage transients down to 1 μs can be • Set of NiMH battery cells
captured. • Simultaneous measurement and dis- Functionality: • Power supply adapter
• Adjustable triggering limits for voltage play of voltage, current phase angles IEC 61000-4-7; • Instruction manual
events. and frequency on two or three-phase IEC 61557-12 • Calibration Certificate
STANDARD SET: systems. • CD with instruction manual, PC SW EuroLink
• Four LEDs indicates the state of the Electromagnetic compatibility:
MI 2130 • Accurate phase angle measurement at IEC 61326-1; IEC 61326-2-2 • Set of carrying straps
instrument (recorded events, low bat-
tery, memory full and incorrect polarity • Instrument VoltScanner low current levels. Safety:
connection). • Mains measuring cable, 1.5 m • Easy to use: large bright LCD display IEC/EN 61010-1
• 1.2 V NiMH rechargeable battery, 4 pcs and large buttons enable easy handling
• PC Software ScanLink is included in a • PC SW ScanLink of the instrument.
standard set and supports download- • RS232 cable STANDARD SET:
• Memory storage for storing up to 1500
ing, data analysis, report creation and • Instruction manual measurements. MI 2230
programming of the instrument as • Calibration certificate • Safe: built for CAT II / 600V environments. • Instrument MI 2230 VAFMeter
well. • Portable: rugged carrying case with a han- • Test lead 4 x 1.5 m
dle and lightweight design enable easy • Test probe, 4 pcs
moving the instrument between sites. • A 1395 Flexible current clamps 30/ 300/ 3000 A
APPLICATION: STANDARDS: • Built in charger & rechargeable batter-
• Supply voltage testing in accordance Functionality: ies: instrument has a built-in charging
with EN 50160; EN 50160 circuit and comes with a set of re-
chargeable NiMH batteries. TECHNICAL SPECIFICATION:
• Ideal solution for IT managers for con- Electromagnetic compatibility:
trol of input voltage; IEC/EN 61326-1 • Downloadable: downloads test results
Safety: via RS232 or USB cable directly to the Function Measuring range Basic accuracy
• Voltage monitoring on the customer’s
PC with the help of the Metrel Eu- Voltage 6 V ... 600 V ±(0,5 % of reading + 3 digits
side for power distribution companies. IEC/EN 61010-1
roLink software. Current
0.1 A ... 20 A ±(1.5 % of reading + 2 digits)
A 1398 - 10 A
3 A ... 30 A ±(1.5 % of reading + 2 digits)
A 1395 - 30 A
TECHNICAL SPECIFICATION: 30 A ... 300 A ±(1.5 % of reading + 2 digits)
APPLICATION: A 1395 - 300 A
300 A ... 3000 A ±(1.5 % of reading + 2 digits)
A 1395 - 3000 A
• VAFMeter instrument is designed to Phase angle -180.0 ... +180.0 ± 0.5°
Measuring function Measuring range Accuracy Resolution be used in general electrical systems Power
Voltage (swells and dips) 70 … 265 Vrms ± (2% of reading + 2 Vrms) 1 Vrms maintenance and commissioning, pro- 0.000 W ... 9999 kW ±(1.5 % of reading. + 4 digts)
Active
Transients 50 … 2600 V ± (10% of reading + 50 Vrms) 5 Vrms tective relay testing, electrical machine 0.000 VAr ... 9999 kVAr ±(1.5 % of reading. + 4 digts)
Reactive
Frequency 47… 62 Hz ± 0.1 Hz 0.1 Hz repairs or in monitoring power at the 0.000 VA ... 9999 kVA ±(1.5 % of reading. + 4 digts)
1 s (for events up to 3.5 min) Apparent
Interruptions < 90 Vrms 8 s (for longer events)
electrical service entrance. PF -1.00 ... 1.00 ±0.04
COM port RS232 • For meter installations, unit measures Cos ϕ 0.00 ... 1.00 ±0.04
Memory module 32 kB phase-to-phase voltage and single-phase THD 0.0 ... 20.0 % ±0.5
Power supply 4 x 1.2 V NiMH rechargeable batteries, type AA current amplitudes and phase angles. 0.0 Ω ... 19.9 Ω ±(3 % of reading + 3 digits)
Over voltage category CAT III / 300 V • Combined with a voltage or current Resistance 20.0 Ω ... 199.9 Ω ±(5 % of reading)
Protection Double insulation source, instrument also becomes an 200 Ω ... 1999 Ω ±(5 % of reading)
Dimensions 103 x 51 x 199 mm excellent tool for testing and calibrating 0.0 Ω ... 19.9 Ω ±(5 % of reading + 3 digits)
Continuity
Weight 515 g virtually any type of protective relay. 20 Ω ... 1999 Ω ±(5 % of reading + 3 digits)
PowerView
PowerView software is a powerful platform for downloading, analysing recorded data and creation of power qualty test Logged data can be analysed according
reports. PC Software contains a package of functionalities needed for profound evaluation of power quality phenomena, to custom or predefined EN 50160 Pow-
data comparison and creation of complex test reports. It works in conjunction with Metrel new generation power quality er Quality criteria
analysers. For the instruments equipped with GPRS functionality PowerView enables remote control of the instrument
as well.
KEY FEATURES:
• User friendly interface: wide range of
quick buttons, possibility to customize
the environment by dragging, docking
and resizing the window tabs.
• Structure: downloaded data is organ-
ized into Windows Explorer-like tree
structure.
• “Drag and drop”: downloaded data
can be easily organized into multiple
sites and sub-site locations.
• Data filtering: data in a structure can
be grouped by quantity or by phase. Results can be represented in both trend
• Views: depending on selected record and table view simultaneously for easier
type, different views are available (Re- analysis
cord Information view, Trend Chart
view, Table view, Waveform Scope
view, Voltage Quality view, etc.)
• EN 50160 analysis: automatic volt-
age quality analysis in compliance
with custom or predefined EN 50160
Power Quality criteria and quick report • On-line monitoring: when instru- • SW update: PowerView checks for
printing. ment is connected with PC, real-time new versions of the application and
• Chart zoom: chart can be zoomed de- observing of signals and parameters is
pending on selected in a table value downloads updates from the Internet
possible via PowerView while instru-
range. ment is measuring / recording in the if necessary.
• Remore control: via GPRS communi- background.
cation remote handling of the instru- • Export of test results: test results can PC SW PowerView is compatible with:
ment and its data can be executed. be exported to other programs (MS Ex- • MI 2792 PowerQ4 Plus
• GPS synchronization: simultaneous cel, MS Word).
measurement on the different net- • MI 2592 PowerQ4
• Reports: automatic generation of test
work points by using 2 or more syn- reports from the selected views and • MI 2392 PowerQPLUS
chronized instruments. data with attached graphs. • MI 2492 PowerQ
Selection Guide for PQA Accessories Selection Guide for PQA Accessories
MI 2792
MI 2592
MI 2392
MI 2492
MI 2130
MI 2792
MI 2592
MI 2392
MI 2492
MI 2130
Part Part
Photo Description Target application Photo Description Target application
number number
High accuracy current clamp 1000 A / 1 V with jaw opening 52 mm Test probe with ∅ 4 mm connection is suitable for performing
Current clamp 1000
A 1033 and fixed 1.5 m cable for power measurements with Metrel pow- – A 1014 Test probe, black measurements both in mains outlets and in situations when no
A/1V
er quality analysers. schuko outlet is present.
Connection cable for Connection cable for connecting current clamps A 1069 and A Crocodile clip assures secure and permanent contact during the
A 1039 – A 1013 Crocodile clip, black
current clamp 1122 on Metrel power quality analysers. measurement on bus bars, fixing screws, etc.
3-phase flexible
3-phase flexible current clamp with three selectable measuring Crocodile clip assures secure and permanent contact during the
A 1179 current clamp – A 1310 Crocodile clip, blue – – – –
ranges. Powered by alkaline or rechargeable batteries. measurement on bus bars, fixing screws, etc.
2000/200/20 A / 1 V
3-phase flexible
3-phase flexible current clamp with three selectable measuring Crocodile clip assures secure and permanent contact during the
A 1257 current clamp – A 1309 Crocodile clip, green – –
ranges. Powered by alkaline or rechargeable batteries. measurement on bus bars, fixing screws, etc.
3000/300/30 A / 1 V
1-phase flexible
Single phase flexible current clamp with three selectable measur- 3-wire test lead for measurements on single or three phase elec-
A 1287 current clamp – A 1011 Test lead, 3 x 1.5 m – – – –
ing ranges. Powered by alkaline or rechargeable batteries. trical installations.
3000/300/30 A / 1 V
Current transformer 5 3-phase transformer for power measure-ments on distribution Safety fuse adapter, Fuse adapters protect the instrument and the user against cur-
A 1037 – S 2014 –
A/1V panels with 5 A nominal output current. 3 pcs rent strike and overload.
GPS Synchronization unit guaranties that the time clock of the Metrel
PowerQ4 Plus analyzer is synchronized according to IEC 61000-4-30. Safety flat clamp, 4 Safety flat clamps assure good contact when connecting the test
A 1355 GPS receiver – – – – S 2015 –
This performance is necessary to ensure that instruments produce pcs leads on busbars and other larger flat surfaces.
the same aggregation results when connected to the same signal.
MI 2792
MI 2592
MI 2392
MI 2492
MI 2130
Part
Photo
number
Description Target application Power Quality Analysis
LAN Cabling Certification
RS232 / USB adapter RS232 / USB adapter for instruments without USB comunication
A 1171
with 1 m cable port.
– – – – Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Small soft carrying Small soft carrying bag for transport and storage of test instru-
A 1020
bag ment or accessories.
–
Voltage and Continuity Testers
Variable transformers /
Large soft carrying bag for transport and storage of test instru-
A 1006 Soft carrying bag
ment and belonging accessories.
–
Equipment for laboratories and Schools
CATALOGUE 2012/13
Option – Not available
Find out more about LAN installations For high capacity LAN networks in class into an adjacent pair with the receiver on ble for the estimation whether the cross- along the link will cause a reflection and fined by standards there are some other
testing. 6 and higher both, Permanent and Chan- the other side. talk’s are critical or not. decrease the signal strength on the re- measurements that may help at analys-
Constant development of IT systems nel link are being tested which urges ceiver end. A change in impedance can ing network conditions and failure find-
requires higher data transmission capa- for high quality test adapters. Regular ELFEXT (Equivalent Level Far End Cross- ACR, Remote ACR occur if using improper cables, cable ing. TDR (time domain reflecto-meter)
bilities of computer networks. Accord- checking of test equipment which may talk) is calculated from FEXT and the ACR (Attenuation to crosstalk ratio) is components or the cable is damaged. is one of such tools which is frequently
ingly these have to be designed and con- include calibration is necessary to assure attenuation on the receiver pair. a comparison of the attenuated regular being used to find a faulty spot along the
structed in such a way to meet the latest reliable test results. The main result is given as the worst signal and disturbing crosstalk signals DC Resistance LAN cable. Test signal is sent along the
requirements which assure long-term case margin in dB to the test standard on the receiver side. High ACR values DC resistance test verifies that the loop tested cable and based on its reflection
usability and expandability of cooper and Measured parameters: limit. High ELFEXT causes typical cross- indicate a high performance connection resistances (sum of resistances of both strength and reflection time a distance
optic fibre cabling. Wire map talk problems: data corruption, retrans- where the crosstalk levels are small in wires) in individual pairs are within the to the faulty spot is calculated.
Wire Map test verifies the pin to pin wir- mitions etc. comparison with attenuation. ACR is given limits.
Testing of structured LAN cabling is an ing and shield continuity. computed from Attenuation and NEXT. Another test function TD NEXT meas-
essential part of certification and main- PSELFEXT, Remote PSELFEXT Additional recommendations ures a distance with the highest cross-
tenance of LAN networks and assures METREL’s hint: PSFEXT (Power Sum Far End Crosstalk) ACR(f) = NEXT(f) - Attenuation(f) Additional to the measurements de- talk along the tested cable.
that all built-in components comply with Split pairs cannot be found with simple defines crosstalk caused by the coupling
proposed regulation. continuity checks. They are detected of signals into a cable pair from other The ACR results consider Attenuation MI 2016 MI 2014
with a simplified NEXT measurement. pairs. The receiver of crosstalk signals is and NEXT. It is taken in account that at Part No.:
Multi LAN 350 Cable Scanner
Typical termination failures: The reason for high crosstalk is not on one cable side and the transmitters on shorter cables the NEXT could be higher
• Broken or open wire; necessarily a split pair - unsuitable and the other cable side on another pair. without degradation of the link perfor-
• Short circuit to shield; careless assembled connectors or cable PSELFEXT (Power Sum Equivalent Level mance. Therefore ACR is very suitable
• Short circuit between wires; faults can also cause a split pair warn- Far End Crosstalk) is calculated from for the estimation whether the cross-
• Crossed, reversed and transposed pairs); ing. The real error source can be easily PSFEXT and the attenuation on the re- talk’s are critical or not.
• Split pairs; defined with the TDCross function. The ceiver pair.
point of error can be easily found by us- High PSELFEXT’s cause typical crosstalk prob- Length
• Other termination problems.
ing the TDR function. At least one pair lems: data corruption, retransmit ions, etc. The length test measures the length of TEST FUNCTIONS
must be connected properly to assure each cable pair. Wiremap
These type of failures can be easily
correct operation of the instrument. RETURN LOSS, Remote RETURN LOSS The cable length is determined from the NEXT / Remote NEXT / −
found with simple test devices called
Return loss is the ratio between trans- time it takes for a pulse to travel along PSNEXT / Remote PSNEXT / −
wire-mapper.
PSNEXT, Remote PSNEXT mitted and reflected signals at the the cable. To get the right result the pulse ELFEXT / PSELFEXT / −
PSNEXT (Power Sum Near End Cross- transmission end. High return loss rates propagation speed has to be known. The Return Loss / Remote Return Loss / −
Hidden failures
talk) defines the coupling on one cable are often caused by local impedance NVP factors can be set (nominal velocity ACR / Remote ACR / −
Proper termination does not necessarily propagation factor, given by percents of
pair from all other pairs. The PSNEXT is mismatching and decrease the signal PSACR / Remote PSACR / −
guarantee proper functioning of cabling light speed) for cables in the Cable Type
calculated from individual NEXT results strength on the receiver end. Length
system. Certain failures can only be found Menu. Since they aren’t exactly defined
and represents the expected worst case Propagation delay −
at high data transmission level or higher Attenuation from the manufacturer (variations can
coupling. Similar to NEXT the coupled
operating frequencies. These limit condi- Delay skew −
signal from other pairs can cause data Attenuation is the measured loss of sig- occur through ageing, different materi-
tions may create signal reflections or in- nal strength in a pair from one cable end als, temperature, number of twists etc) Impedance −
corruption, retransmit ions and other
terferences in adjacent pairs or cables. A problems. This is especially critical in to the other. It increases with frequency the length results are only indicative. The DC resistance −
common source of such problems are multi-pair data protocols. and cable length so it has to be measured problem intensifies at longer lengths. Attenuation −
installed network components like sock- over the complete frequency range. At- TDR
ets and plugs that in combination with NEXT, Remote NEXT tenuation is one of the main cable pa- Delay Skew TDR with TDnext
built-in termination failures contribute to NEXT (near end crosstalk) defines the rameters that dramatically influences the Delay skew is the difference in propaga- FEATURES
data transmission problems. coupling between adjacent pairs. High maximum bit rate of data stream allowed. tion delays between test pulses through Frequency range 0 ... 350 MHz −
level signals transmitted in one pair on different cable pairs. The shortest delay CAT 6 −
Such failures can be easily found with a cable end can induce a substantial dis- PSACR, Remote PSACR is referenced to 0ns. High delay skews CAT 5 / 5e / /
advanced LAN testers that do not only turbance signal in the neighboring pairs, PSACR (Attenuation to crosstalk ratio) is can cause trouble especially when fast Coax cable −
check wiring but also measure a number on the same (transmitter) side. This a comparison of the attenuated regular multi-pair data protocols are used. Internal memory −
of other electrical parameters in a wide signal added to the signals transmitted signal and disturbing crosstalk signals Cable tracer option −
frequency bandwidth. from the other cable can cause data from other pairs on the receiver side. Propagation Delay PC Software −
corruption, retransmit ions and other PSACR is computed from Attenuation Propagation delay is the time it takes a RS232 port and cable −
Regulations and standards problems. The most common causes and PSNEXT. test pulse to travel the length of each
USB port and cable −
Specification of LAN certifying testers, for NEXT problems are poor twisting on cable pair.
Talk over copper (Talk set)
their measuring accuracy, presentation connector points, non matched connec- PSACR(f) = PSNEXT(f) - Attenuation(f)
Cable identifiers
form of test results and their limit values tion components, split pairs etc. Impedance
RJ 45 output
have been defined in various standards. PSACR results consider Attenuation Impedance is a characteristic of the
cable. In general the characteristic im- BNC output −
In EU countries it is common that na- ELFEXT, Remote ELFEXT and PSNEXT. It is taken in account that
at shorter cables the PSNEXT could be pedances in high frequency systems GENERAL DATA
tional legislations refer to the EN 50173, FEXT (Far End Crosstalk) defines cross-
while globally IEC 11801 is being used talk caused by the coupling of a signal higher without degradation of the link must be matched to ensure a regular Dimensions 265 x 110 x 185 mm 156 x 100 x 190 mm
with the TIA 568B specified in the US. from a pair transmitted on one cable side performance. Therefore it is very suita- data flow. Every change in impedance Weight 2.1 kg 1 kg
MEASURING FUNCTIONS: The MI 2014 Cable Scanner is a portable handheld battery powered instrument The LAN Link software enables enables downloading, analysing of stored data and transfering latest observed cable char-
intended for testing LAN installations and cables. This simple but effective de- acteristics for detailed further research on LAN and Telecommunication Cable Installations.
• Cable length;
vice performs copper terminations testing on shielded and unshielded LAN and
• TDR (Time Domain Reflectometer);
coax cables. With optional Tracer can be performed tracing of cables and wires.
• Time Domain Crosstalk;
• Wire map test. Talk function enables full duplex communication between remote operators.
Due to user friendly interface handling of the instrument is simple and clear. KEY FEATURES:
• User friendly interface: wide range
KEY FEATURES: of quick icons, for downloading, ex-
porting, viewing and reorganizing data.
• Fast termination fault finding with • Downloading Autotest results or
graphical indication of the failure type. Plots: After connecting the Multi LAN
• Integrated high accuracy TDR function 350 to a PC stored Autotest Results or
with adjustable NVP factor measures memorized Plots can be downloaded.
• Structure organized data: download-
distance to the fault. ed data are organized into tree struc-
• Internal tone generator combined with ture where the locations could be
an optional Cable tracer serves for renamed and / or equiped with com-
wire finding in bounces of cables. ments. Separate Object, Floor or Ca-
• Locators for simplified identification of ble location number could be changed
sockets are included in a standard set. to any alphanumeric name.
• Optional Talk Remote Unit allows voice • Creating test Reports: automatic
generation of test reports from the
communication over the tested cable. selected views and data with attached
• Instrument’s outputs allow testing on graphs. The Operator/Test site menu
RJ 45 and coax terminations. enabeling the operator to create his
own Test Report Header and Footer.
BMP logo can be added.
APPLICATION: • Comments menu: any text can be
added to the Test Report Header.
• Troubleshooting and maintenance of • Evaluation and printout of three • Export of test results: test results After connecting the Multi LAN 350 to
LAN and other cable networks. different levels of Test Reports: can be exported to other programs a PC stored Autotest Results or memo-
• Full Detail Report provides the most rized Plots can be downloaded.
complete information about the per- (MS Excel, MS Word).
STANDARDS: formed measurements including Pass/ • Viewing Plots: Graphs and plots of
Fail decision for performed measure- NEXT, ELFEXT, PSNEXT, PSELFEXT,
Electromagnetic compatibility: ments, overall headroom results or Attenuation, Return Loss, ACR,
EN 50081-1; margins for individual pairs.
EN 50882-1 PSACR, TDR and TDnext can be
• Medium Detail Report shows Pass/
Safety: Fail decision for performed measure- downloaded, viewed and printed. The
EN 611010-1 ments and the overall headroom for plots contain additional information
individual cables are displayed. about Test Standard and Cable Type,
• Low Detail Report enables you to date & time of measurement etc.
STANDARD SET: make a clear and simple Test Report
providing essential information of the
MI 2014 overall Pass/Fail decision and head- PC SW LAN Link is compatible with:
• Instrument Cable Scanner room for individual cables. • MI 2016 Multi LAN 300
• Cat 5 Patch cable, 2 pcs
• Standard Remote #1
• Locators (#1 ... #4), 4 pcs
• Instruction manual TECHNICAL SPECIFICATION:
• Calibration certificate
MI 2016
MI 2014
Part
Photo
number
Description Target application Power Quality Analysis
LAN Cabling Certification
Large soft carrying bag for transport and storage of test instrument and belonging
A 1006 Soft carrying bag
accessories.
Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Carrying strap for carrying the measuring instrument around the neck allowing free
A 1007 Carrying strap
hand use of the tester.
–
Voltage and Continuity Testers
Variable transformers /
Headphones with Talk set with two earphones allows communication over the tested communication
A 1041
microphone, 2 pcs cable.
Equipment for laboratories and Schools
Locator set II (#5 to Locators simplify and accelerate nummerification and identification of LAN sockets.
A 1043
#16) Set includes locators with number from #5 up to #16.
Locator set III (#17 Locators simplify and accelerate nummerification and identification of LAN sockets.
A 1044
to #28) Transponders with numbers from #17 up to #28 are delivered with the set.
GOOD TO KNOW
1.2 V NiMH battery,
A 1046
type C, 6 pcs
A set of 6 pieces of rechargeable batteries, type C. – Indoor Environment Quality 6 - 02
Selection Guide for Indoor Environment Quality Analysers 6 - 04
MI 6201 Multinorm 6 - 06
Cable tracer is intended for wire tracing on dead or live low voltage installations. To MI 6301 FonS 6 - 08
A 1082 Cable tracer –
be used with MI 2014. MI 6401 Poly 6 - 10
PC SOFTWARE
Power supply adapter SensorLink 6 - 12
A 1083 with 6 pcs NiMH bat- Battery charger and a set of 6 pieces of rechargeable batteries, type AA. – SoundLink 6 - 13
teries, type AA
Selection Guide for IEQ Accessories 6 - 14
Talk remote unit with Talk set includes Talk remote unit and two earphones and enables communication
S 2004 –
headphones set over the tested computer or phone line. To be used with MI 2014.
Standard remote set contains a package of locators with numbers from #2 up to #6 for
Standard remote set
S 2005 detailed measurements on communication connections and identification of sockets. –
(#2 ... #6)
To be used with MI 2014.
Standard remote set contains a package of locators with numbers from #7 up to #15
Standard remote set
CATALOGUE 2012/13
S 2006 for detailed measurements on communication connections and identification of sock- –
(#7 ... #15)
ets. To be used with MI 2014.
Find out more about Indoor Environ- Thermocouple Temperature (°C), Tem- cated by a moistened thermometer bulb votes of a large group of persons. PMV leaving a point on a surface in a given as air, which is indoor mainly produced
ment Quality parameters testing perature Difference (°C) exposed to the air flow. index is calculated automatically by Me- direction, the unit of measurement is by humans. It becomes toxic in higher
Indoor Environmental Quality (IEQ) en- Thermocouple is a device for accurate trel instruments from the inputs of air candelas per square meter (cd/m2). concentrations. 1% (10,000 ppm) con-
compasses all aspects of the indoor wide range measurement of tempera- Wet bulb temperature can be calculated temperature, mean radiant temperature, centration will make some people feel
setting including air quality, ventilation, ture. It consists of two wires of different or measured using a thermometer with relative humidity, air velocity, clothing Luminance indicates how much lumi- drowsy, concentrations of 7% to 10%
metals joined at each end. One junction the bulb wrapped in wet muslin. A wet thermal resistance and metabolic rate. nous power will be perceived by an eye cause dizziness, headache, visual and
thermal comfort, lighting and noise.
is placed where the temperature is to bulb thermometer measures the extent looking at the surface from a particular hearing dysfunction, and unconscious-
be measured, and the other is kept at a of cooling as moisture dries from a sur- The PMV index should be in the bounda- angle of view. ness within a few minutes to an hour.
Indoor air quality (IAQ) refers to the
constant lower (reference) temperature. face (evaporative cooling). The wet bulb ries from –0.7 to 0.7 for acceptable ther-
quality of the air inside buildings as rep-
Since voltage changes in proportion to temperature is always lower than the mal environment in indoor places. Luminance probe measures luminance Recommended level is not more than
resented by concentrations of pollut-
temperature (41 μV/°C), the measured dry bulb temperature except when there of different surfaces. The silicon photo- about 700 ppm over outdoor ambient
ants and the thermal (temperature and is 100% relative humidity.
relative humidity) conditions that affect voltage difference indicates temperature PMV value Thermal sensation scale cell measures light received by the lens; (1,000 ppm equals 0.1%).
the health, comfort, and performance differences. 3 to 2 hot acceptance angle is 3.5°.
Black Globe Radiant Temperature (°C) 2 to 1 warm Sound parameters
of occupants. Other factors affecting Black Globe Radiant Temperature is
occupants, such as light and noise, are If the thermocouple probe is connected 1 to 0.7 slightly warm Diameters of measuring area for differ- Sound is a disturbance of mechanical
amount of heat accepted by the body ent probe-surface distances: energy that propagates through matter
important indoor environmental quality to the instrument the temperature differ- 0.7 to 0.7 neutral
due to the radiation of either direct light as a wave. Sound is characterized by the
considerations. ence between measured thermocouple -0.7 to -1 slightly cold
or hot objects in the environment. -1 to -2 cool properties of sound waves, which are
temperature and air temperature is cal- Probe to surface distance (m) Diameter of measuring area (mm)
Poor indoor air quality can lead to a culated: -2 to -3 cold 0.75 46 frequency, wavelength, period, ampli-
For instance, if the sun is setting, turn-
number of physical symptoms and 1 61 tude and velocity or speed.
ing to night, you may feel a coolness, PMV values
complaints like headaches, fatigue, ΔT=TC -T although the temperature is unchanged
2 122
shortness of breath, sinus congestion, PPD Index (%) 3 185 Sound pressure is the pressure deviation
at that moment.
coughs, sneezing, eye, nose, and throat ΔT - temperature difference; PPD (Predicted Percentage of Dissatis- 4 245 from the local ambient pressure caused
irritation, skin irritation, dizziness, nau- TC - thermocouple temperature; fied) is an index that predicts the number
5 305 by a sound wave.
WBGT Index (°C) 6 365
sea, etc. T - air temperature. WBGT (Wet Bulb Globe Temperature) in- of thermally dissatisfied persons among
dex is composite temperature used to es- a large group of people.
7 430 As the human ear can detect sounds
A healthy and comfortable indoor envi- Relative Humidity (%) timate the effect of temperature, humidity, The PPD index should be less than 15 with a very wide range of amplitudes,
Contrast sound pressure is often measured as
ronment relies on a correct combination Relative humidity is a term used to de- and solar radiation on humans. It is used % for acceptable thermal environment Contrast is difference in the color and a sound level on a logarithmic decibel
of temperature, humidity, air movement scribe the ratio of the amount of water by industrial hygienists, athletes, and the in indoor places. brightness of the object and other ob- scale (dB).
and task lighting. vapor in the air at a specific temperature military to determine appropriate exposure The PPD index is automatically shown jects within the same field of view.
to the maximum amount that the air levels to high temperatures. by Metrel instruments.
Measurements that can be performed could hold at that temperature. Sound level (dB)
CO Concentration (ppm) Since the human ear does not have a
with Metrel IEQ instruments: The WBGT index is the most widely used Illuminance (Lux) Carbon monoxide is one of the most flat spectral response, sound levels are
• Air Temperature (°C) The two most common electronic sen- heat stress index and is standardized in Illuminance is a term expressing the
• Thermocouple Temperature (°C) acutely toxic indoor air contaminants, often frequency weighted so that the
sors are used to measure humidity: ISO 7243. Metrel instruments supports density of luminous flux incident on a
• Temperature Difference (°C) it is colourless, odourless, tasteless, measured level will match perceived
capacitive or resistive. The capacitive automatic indoor WBGT index calculation: surface:
• Relative Humidity (%) highly poisonous gas. CO is a by-prod- levels more closely.
sensors sense water by applying an AC uct of incomplete combustion of fos-
• Dew Point (°C) signal between two plates and measur- WBGT (indoor) = 0.7 * TWB + 0.3 * TG E = dF / dA, • A-weighting attempts to match the
• Natural Wet Bulb Temp. (°C) sil fuels. Common sources of carbon response of the human ear to noise
ing the change in capacitance caused by monoxide are tobacco smoke, space
• Black Globe Radiant Temperature (°C) the amount of water present. TWB – Natural wet bulb temperature; where A is the area of the illuminated Label is dB(A).
• WBGT Index (°C) TG – Black globe temperature. heaters using fossil fuels, defective • C-weighting is used to measure peak
surface and F is the luminous flux.
• Air Velocity (m/s) central heating furnaces and automo- levels.
Dew Point (°C) bile exhaust. By depriving the brain of
• Air Flow (m3/h) The dew point is the temperature at Air Velocity (m/s) Common levels of Illuminance in various
• PMV Index Velocity is distance travelled per unit of oxygen, high levels of carbon monox-
which air becomes saturated when conditions:
• PPD Index (%) time, usually it is expressed in meter per ide can lead to nausea, unconscious-
cooled without addition of moisture or 40
• Illuminance (Lux) second (m/s). Air Velocity is measured ness and death.
change of pressure. Any further cooling Lumens per Square Meter (lm/m2 or lux) 30
• Luminance (cd/m2) causes condensation, fog and dew are with hot wire anemometer. Sunlight alone (maximum) 102.000
• Contrast CO acceptable levels: 20
formed in this way. Television stage 25.000
• CO Concentration (ppm) Air Flow (m3/h) Skylight alone (maximum) 16.000 10
• CO2 Concentration (ppm) Dew point is calculated from air tem- By multiplying air velocity by the cross Dull day 1.000 Averaging
Maximum Maximum Maximum (D)
Desirable Acceptable Tolerable 0
• Sound level (dB) perature and relative humidity, so for section area of a duct, the air volume Merchandise display indoors 1.000
Times
Level Level Level
(D)
(B, C)
-10
• 1/1 Octave Analysis accurate measurement the longer ex- flowing past a point in the duct per unit Recommended for reading 500 1 hour 13 ppm 30 ppm n/a
(B)
• 1/3 Octave Analysis position time of air temperature or rela- of time can be determined; unit is usu- Public areas in buildings 300 8 hours 5 ppm 13 ppm 17,4 ppm -20
tive humidity measurements should be ally cubic meter per hour (m3/h). Moonlight 0.4 -30
IAQ parameters considered. Starlight 0.002 CO2 Concentration (ppm) (A) Not defined
-40
Air Temperature (°C) PMV Index Carbon dioxide is a colourless, odour-
Temperature is the degree of hotness or Natural Wet Bulb Temperature (°C) PMV (Predicted Mean Vote) is an index, Luminance (cd/m2) less, tasteless, incombustible and “non- -50
10 100 1000 10K 100K
coldness of a body or environment. Natural Wet Bulb temperature is indi- which predicts the mean value of the Luminance is the amount of visible light toxic” gas, about 1.5 times as heavy
Indoor Environment Quality Selection Guide for Indoor Environment Quality Analysers
1/1 and 1/3 Octave Analysis to 8000 Hz and broadband bar graph for MI 6201PR MI 6201EU MI 6201ST MI 6301PR MI 6301EU MI 6401EU MI 6401ST
Part No.:
Octave is an interval between two broadband measurements: Multinorm FonS Poly
sounds having a ratio of two to one in 31-62-125-250-500-1000-2000-4000-8000.
terms of their frequency span. For ex-
ample, 200 Hz is an octave higher than 1/3 Octave Analysis
100 Hz; 400 Hz is one octave higher than Frequency bar graph with 27 bars repre-
200 Hz. senting 27 one-third octave bands from
25 Hz to 10000 Hz and broadband bar
Octave bands are classified according to graph for broadband measurement:
their geometric centre frequency based 25-31-40-50-62-80-100-125-160-200- MEASUREMENTS
on the internationally standardized 1000 250-315-400-500-630-800-1000-1250-
starting point. The 1000 Hz or 1 kHz band 1600-2000-2500-3150-4000-5000-6300- Air Velocity − −
has limits of about 707 and 1414 Hz. 8000-10000 Air Flow − −
Relative Humidity − −
Frequency analysis mode (1/1 and/or 1/3 Class 1 / Class 2
Dew point − −
octave analysis) is usually used if there is Sound measuring instruments, processors
a need to improve acoustic properties of and probes are classified as being Class 1 Air teperature − −
a room or working place. The results of or Class 2 according to the measurement Temperature difference Option Option Option − − Option Option
frequency analysis show in which part of accuracy achieved. A class 1 instrument K Thermocouple temperature Option Option Option − − Option Option
the acoustic spectrum noise originates, may only be formed by combining a class
Illuminance − −
and which frequency components 1 probe with a class 1 processor. Class 1
should thus be attenuated. processor shall, at least, cover the range Luminance Option Option Option − − Option Option
from 45 Hz to 7.1 kHz in one third octave Contrast Option Option Option − − Option Option
1/1 Octave Analysis bands. Class 2 processor shall, at least,
Black globe radiant temperature Option Option Option − − Option Option
Frequency bar graph with 9 bars repre- cover the same range, or 45 Hz to 5,6 kHz
senting nine octave bands from 31 Hz in octave bands, as specified in ISO 9614. CO concentration Option Option Option − − Option Option
CO2 concentration Option Option Option − − Option Option
Sound level, class 1 (IEC 1672) − − − − −
Sound level, class 2 (IEC 1672) − − − −
Real time 1/1 octave analysis − −
Real time 1/3 octave analysis − −
TEST PROBES
A 1091 Microclimatic probe − −
A 1127 Humidity and temperature probe Option Option Option − − Option Option
A 1092 Illuminance probe, type B − −
A 1132 Luminance probe Option Option Option − − Option Option
A 1128 Thermocouple probe, type K Option Option Option − − Option Option
A 1146 Sound probe, class 1 − − − − −
A 1151 Sound probe, class 2 − − − −
A 1131 Black globe thermometer Option Option Option − − Option Option
A 1180 CO2 probe Option Option Option − − Option Option
A 1181 CO probe Option Option Option − − Option Option
PC SOFTWARE
A 1134 SensorLink PRO − −
A 1167 SoundLink LITE − −
A 1162 SoundLink PRO Option Option Option Option Option − −
CERTIFICATES
ISO calibration certificate for complete
− −
system
Calibration certificate − − − − −
SensorLink SoundLink
The SensorLink software works in conjunction with Metrel downloadable Indoor Environment Quality testers. The soft- The Sound Link software works as a program for downloading, storing and retrieving measurement data from Metrel
ware automatically recognizes connected instrument and allows the customer to download test results saved on the instruments MI 6201 Multinorm and MI 6301 FonS.
instrument, review the results and print test reports. The Sensor Link is compatible with Metrel instruments MI 6201
Multinorm and MI 6401 Poly.
Selection Guide for IEQ Accessories Selection Guide for IEQ Accessories
MI 6401
MI 6301
MI 6201
MI 6401
MI 6301
MI 6201
Part Part
Photo Description Target application Photo Description Target application
number number
Sound calibrator, Sound calibrator Class 2 is intended for periodical calibration and accuracy inspec- Extension cable for A 1 m long extension cable can be used in combination with luminance and illumi-
A 1165 – A 1145 –
class 2 tion of the instrument. 1092 and A 1132, 1 m nance probe for measurements on remote spots.
Sound calibrator, Sound calibrator Class 1 is intended for periodical calibration and accuracy inspec- Tripod is used for instrument fixing at long term measurements of sound and
A 1152 – A 1159 Tripod
class 1 tion of the instrument. other indoor air quality parameters.
Tripod holder for black Tripod holder assures fixing of the test instrument and Black globe thermometer
A 1180 CO2 probe Probe measures concentration of carbon dioxide in the ambient air. – A 1161 –
globe thermometer on tripod.
PC SW SoundLink SoundLink PRO is a complete PC software for downloading, test data evaluation,
A 1181 CO probe Probe measures concentration of carbon monoxide in the ambient air. – A 1162 –
PRO profound sound analysis and test report creation.
Type K thermocouple probe with measuring range from -20 °C to 1400 °C for
Thermocouple probe,
A 1128 contact temperature measurements of various surfaces like motors, transform- –
type K
ers, etc.
Telescopic rod with The extension rod helps at measurements on remote spots like ventilation ducts
A 1130 –
2.5 m cable and other places that cannot be easily reached by hand.
CATALOGUE 2012/13
6. 16 Accessories: page 6.14 Accessories: page 7.30
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
GOOD TO KNOW GOOD TO KNOW
Find out more about DMMs and TRMS (True RMS) value A DMM’s ability to measure AC volt- Diode test
Clamp Meters. TRMS is a specific method of measuring age can be limited by the frequency of This mode measures and displays the
Handheld digital multimeters (DMM) the RMS value of a signal. With induc- the signal. Most DMMs can accurately actual voltage drop across a junction. A
are among the most widely used instru- tive and capacitive systems distorting measure AC voltages with frequencies silicon junction should have a voltage
ments for equipment testing when it the sinusoidal wave of the mains supply, from 50 Hz to 500 Hz, but a DMMs AC drop less than 0.7 V when applied in the
comes to servicing, repairing, and install- this method provides the most accurate measurement bandwidth may be hun- forward direction and an open circuit
ing applications. RMS value regardless of the shape of dreds of kilohertz wide. Such a meter when applied in the reverse direction.
the waveform. may read a higher value because it is
When the red (+) lead is connected to
capable to see more of a complex ac sig-
A DMM is a digital meter that is capa- the anode and the black (-) to the cath-
nal. DMM accuracy specifications for AC
ble of making various types of measure- ode, the diode should conduct and the
Resolution voltage and AC current should state the
ment. It may have any number of special meter will display a value (usually the
frequency range along with the range’s
features, but mainly a DMM measures Resolution is the smallest possible voltage across the diode in mV, 1000mV
accuracy.
volts, ohms, and amperes. DMMs are change in a signal that would produce = 1V). After rversing the connections
used to troubleshoot electrical problems a change in the value on the screen of the diode should not conduct this way
Frequency is measured in hertz (Hz) the
in a wide array of industrial and house- the test instrument. For example, if the so the meter will display “OL”.
number of times per second a waveform
hold devices such as batteries, motor DMM has a resolution of 1 mV on the 4
repeats. Maintaining the right frequency
controls, appliances, power supplies, V range, it is possible to see a change of is crucial for devices that rely on AC volt-
and wiring systems. 1 mV (1/1000 of a volt) while reading 1 V. age and current. Capacitance
To test capacitance, set the dial on the
Metrel DMMs are appropriate for test- DMM to the capacitance function and
Accuracy Crest factor
ing under tough conditions and can be plug in your leads. After ensuring that
Accuracy is a value to show how accu- The crest factor describes the ratio of the
tossed into tool cases. the capacitor has been discharged, con-
rately an instrument can read a specific peak value to the RMS value of an electrical nect the test leads to the capacitor ter-
value. This is usually written as a per- variable (AC voltage and AC current).
When choosing a clamp meter not only minals and take a reading. If the meas-
centage (e.g. 5 V ± 5 %). An accuracy of High crest factors cause distortion
look at specifications, but also pay at- urement is similar to the rating listed on
one percent of reading means that for a of the reactive power and harmon-
tention to features, functions, and the the capacitor, the capacitor is good. A
displayed reading of 100 volts, the actual ics in the supply network, and so are
overall value represented by a meter’s significant variation from the rating indi-
value of the voltage could be anywhere undesirable.
design: cates the capacitor should be replaced.
between 99 volts and 101 volts.
• Choose a clamp meter that gives ac-
curate and repeatable results. Resistance
• For precise measurements choose Resistance values can vary greatly, from DC and AC current
Number of Counts
a clamp meter which reports TRMS a few milliohms (mΩ) for contact resist- Current measurements are different
The number of divisions into which a
reading. Otherwise noise from every- ance to billions of ohms for insulators. from other DMM measurements. Cur-
given measuring range is divided. This
thing from a variable frequency drive can be used to evaluate the resolution of Most DMMs measure from 0.1 Ω, up rent measurements taken with the
to compact fluorescent bulbs can re- an instrument. to 300 MΩ. At Metrel DMM display is DMM alone require placing the meter in
sult in a less accurate reading. infinite resistance (open circuit) read as series with the circuit being measured.
• Make sure that the clamp meter is “OL” and means that the resistance is This means opening the circuit and using
specified to work in the environment greater than the meter can measure. Re- the DMM test leads to complete the cir-
The basics of measurements
you do and that are rugged enough to sistance measurements must be made cuit. This way all the circuit current flows
DC and AC voltage
continue to give reliable results even in with the circuit power off – otherwise, through the DMMs circuitry.
One of the most basic tasks of a DMM
case they drop from ladders or bounc- the meter or circuit could be damaged.
is measuring voltage. A typical DC volt-
ing in your tool case. age source are the batteries while AC
• Be sure the clamp meter display has voltage is usually created by a generator. Current with Clamp Meter
Continuity
large, easy to read characters. The wall outlets are common sources of Today’s clamp meters are capable of
Continuity is a quick “go/no-go” resist-
AC voltage. measuring both AC and DC current.
ance test that distinguishes between an
open and a closed circuit. A DMM with Typical current measurements are taken
RMS (Root Mean Square) value Testing for proper supply voltage is usu- a continuity beeper allows you to com- on various branch circuits of an electri-
When an AC supply is placed onto a cir- ally the first step when troubleshooting plete many continuity tests easily and cal distribution system. By taking current
cuit, it produces heat. The RMS value is a circuit. If there is no voltage present, quickly. The DMM will beep if there is measurements along the run of a branch
the equivalent DC supply that would pro- or if it is too high or too low, the voltage good continuity, or a good path that al- circuit, it can be easily determined how
duce the same amount of thermal heat problem should be corrected before in- lows current to flow. If there is no conti- much each load along the branch circuit
as the actual AC supply. vestigating further. nuity, the DMM won’t beep. is drawing from the distribution system.
Part No.: MD 9060 NEW MD 9050 MD 9040 MD 9035 NEW MD 9030 MD 9020 MD 9016 NEW MD 9015 MD 9010
True RMS − − − − −
DC current range (A) 10 10 10 10 10 10 8 10 0.002
Basic accuracy (%) 0.15 0.2 0.2 0.7 1.2 1.2 0.5 0.8 1.2
Maximum resolution (µA) 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
AC current range (A) 10 10 10 10 10 10 8 10 0.002
Basic accuracy (%) 0.5 0.6 0.6 2.2 1.5 1.5 1.0 1 1.5
Maximum resolution (µA) 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
DC voltage range (V) 1000 1000 1000 1000 1000 1000 1000 1000 600
Basic accuracy (%) 0.02 0.06 0.06 0.4 0.3 0.3 0.4 0.3 0.5
Maximum resolution (µV) 10 10 10 10 100 100 10 100 1000
AC voltage range (V) 1000 1000 1000 1000 1000 1000 1000 750 600
Basic accuracy (%) 0.3 0.5 0.5 2.0 1.5 1.5 1.0 1 1.5
Maximum resolution (µV) 10 10 10 10 100 100 10 100 1000
Resistance measurement (MΩ) 50 60 60 60 40 40 60 25 6
Basic accuracy (%) 0.07 0.1 0.1 0.5 0.6 0.6 0.5 0.4 1
Maximum resolution (mΩ) 100 100 100 100 100 100 100 100 100
Acoustic continuity test
Diode test
Capacitance
Frequency measurement
Frequency of digital signals − − − − −
T1 & T2 T1 & T2
Temperature measurement (Type K sensor) − T1 T1 T1 T1 T1 −
(temperature comparison) (temperature comparison)
Autocheck V / Ω
®
− − − − − − −
Conductance (nS) − − − − − − −
IP-RPM (Inductive pickup type) − − − − − − − −
IG-RPM (Contact signal type) − − − − − − − −
Dwell – Angle function − − − − − − − −
% - Duty Function − − − − − − − −
Fuel injection – ms detector − − − − − − − −
100 kHz Voltage Bandwidth − − − − − − − −
Variable frequency drive − − − − − − − −
50.000 (fast mode) 9999 (AC/DCV, Hz, nS)
Count 500.000 (DCV) 6000 4000 4000 6000 2500 6000
6000 (mV, µ/m/A, Ω , F)
99.999 (Hz)
Backlight − − − − −
Analogue bar-graph 41 segment 41 segment 41 segment 24 segment − − 24 segment − −
IR, RS232 interface − − − −
Automatic and manual range selection Auto
Automatic switch off
Non-contact eletrical field detection (EF) − − − − −
MAX hold − − − − −
Peak hold − − − − − − −
Data hold −
Recording (MAX / MIN / AVG) − − − − − −
Relative value − −
Compensation for test leads − − − − − − −
CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V CAT III / 300 V
Overvoltage category CAT IV / 1000 V CAT IV / 1000 V CAT IV / 1000 V CAT II / 1000 V CAT III / 600 V CAT III / 600 V CAT III / 600 V CAT III / 600 V CAT II / 600 V
CAT II / 1000 V CAT II / 1000 V CAT II / 1000 V CAT II / 1000 V
Dimensions with holster (mm) 208 x 103 x 64.5 208 x 103 x 64.5 208 x 103 x 64.5 161 x 80 x 50 198 x 97 x 55 198 x 97 x 55 161 x 80 x 50 160 x 82 x 48 113 x 53 x 10.2
Weight with holster (g) 635 635 635 340 396 396 340 345 78
CE mark
MD 9060 TRMS, 500.000 counts LCD, 100 kHz Voltage Bandwidth TECHNICAL SPECIFICATION:
MD 9050 TRMS Heavy Duty Industrial Digital Multimeter MD 9040 TRMS Industrial Digital Multimeter
The MD 9050 ranks among the best multimeters on the market. High resolution and accuracy, 2-line LCD display, fast data acquisi- CAT IV / 1000 V overvoltage category and TRMS measurement of AC current and voltage are key features of the MD 9040.
tion and transfer (via optical interface), CAT IV / 1000 V, TRMS current and voltage measurement, non-contact voltage detection, That’s why it is particularly suitable for performing measurements on power supply sources in the most demanding ap-
conductance measurement, auto check function and fast one-handed operation are highlights of the multimeter. The MD 9050 plications in the industrial sector. Its high accuracy, 2-line LCD display, diverse measurement functions, fast one-handed
is the ideal choice for demanding measurement tasks in industry, in the laboratories and in everyday repair and maintenance operation and outstanding value for money open up a wide range of possible uses.
practice.
MEASURING FUNCTIONS: MEASURING FUNCTIONS:
• TRMS AC, DC voltage measurement; • TRMS AC, DC voltage measurement;
• TRMS AC, DC current measurement; • TRMS AC, DC current measurement;
• Capacitance measurement;
• Resistance measurement; • Capacitance measurement;
• Diod test; • Resistance measurement;
• Mains supply frequency measurement; • Diod test;
• Frequency of digital signals measurement;
• Continuity test (acoustic signalling); • Mains supply frequency measurement;
• Conductance measurement; • Frequency of digital signals measurement;
• Electric field detection; • Continuity test (acoustic signalling).
• Temperature measurement.
KEY FEATURES:
KEY FEATURES:
• TRMS: accurate readings on sinusoidal • TRMS: accurate readings on sinusoidal
and non-sinusoidal signals. and non-sinusoidal signals.
• Autocheck function: automatic de- • Lead alert: incorrect lead connection
tection of AC voltage, DC voltage or alert.
resistance.
• Auto-ranging: user can switch be- • Auto-ranging: user can switch between
tween auto and manual ranging. auto and manual ranging.
• Temperature measurement: meas- • Relative zero mode: relative function
ures T1, T2 and T1 + T2 temperature
in Celsius and in Fahrenheit. for comparing the difference between
• EF detection: non-contact and probe- signals or removing background noise.
contact electric field detection. • MAX/MIN/AVG: recording of maxi-
• Lead alert: incorrect lead connection alert. mum, minimum and average values.
• Relative zero mode: relative function
for comparing the difference between • Data Hold: data hold feature freezes
signals or removing background noise. the display for later view.
• MAX/MIN/AVG: recording of maxi- • PC Link: test results can be download-
mum, minimum and average values.
• Data Hold: data hold feature freezes TECHNICAL SPECIFICATION: ed to the computer via the optional PC TECHNICAL SPECIFICATION:
the display for later view. software.
• Peak Hold: Crest (instantaneous peak) • Frequency measurement: up to 1
cupture mode. Function Range Accuracy Function Range Accuracy
• PC Link: test results can be download- MHz.
TRMS AC and AC+DC voltage 60.00 mV … 999.9 V from ±(0.5 % of reading + 3 digits) TRMS AC voltage from ±(0.5 % of reading + 3 digits)
ed to the computer via the optional PC (40 Hz … 20 kHz) to ±(3.0 % of reading + 4 digits) • Safety: CAT IV / 1000 V overvoltage 60.00 mV … 999.9 V
(40 Hz … 20 kHz) to ±(3.0 % of reading + 4 digits)
software. Autocheck (ACV) 9.999 V … 999.9 V ±(1.0 % of reading + 4 digits) protection.
• Safety: CAT IV / 1000 V overvoltage from ±(0.06 % of reading + 2 digits)
DC voltage 60.00 mV … 999.9 V from ±(0.06 % of reading + 2 digits) • Easy to read: large bright 4 digits 9999 DC voltage 60.00 mV … 999.9 V
protection. to ±(0.12 % of reading + 2 digits) to ±(0.12 % of reading + 2 digits)
• Backlight: large bright 4 digits 9999 Autocheck (DCV) 9.999 V … 999.9 V ± (0.5 % of reading + 3 digits) counts dual LCD display.
DC current 600.0 µA … 10.00 A ±(0.2 % of reading + 4 digits)
counts dual LCD display with backlight DC current 600.0 µA … 10.00 A ±(0.2 % of reading + 4 digits)
for working in dark conditions. TRMS AC current from ±(0.6 % of reading + 3 digits)
TRMS AC and AC+DC current 600.0 µA … 10.00 A from ±(0.6 % of reading + 3 digits) 600.0 µA … 10.00 A
(40 Hz … 1 kHz) to ±(1.0 % of reading + 4 digits) APPLICATION: (40 Hz … 1 kHz) to ±(1.0 % of reading + 4 digits)
2.000 V ±(1.0 % of reading + 1 digit) 2.000 V ±(1.0 % of reading + 1 digit)
APPLICATION: Diode test Open-circuit voltage <3.5 VDC, test current 0.4 mA • High level industrial testing; Diode test
from ±(0.1 % of reading + 3 digits) Open-circuit voltage <3.5 VDC, Test current 0.4 mA
• High level industrial testing; Resistance 600.0 Ω … 60.00 MΩ to ±(1.5 % of reading + 5 digits) • High level electronic fault finding;
• High level electronic fault finding; from ±(0.1 % of reading + 3 digits)
Conductance 99.99 nS ±(0.8 % of reading + 10 digits) • Field servicing; Resistance 600.0 Ω … 60.00 MΩ
• Field servicing; from ± (0,5 % of reading + 4 digits) to ±(1.5 % of reading + 5 digits)
Autocheck (resistance) 600.0 Ω … 60.00 MΩ • Heavy duty electrical testing.
• Heavy duty electrical testing. to ±(2 % of reading + 5 digits) Mains frequency 15.00 Hz … 50.00 kHz ±(0.04 % of reading + 4 digits)
Mains frequency 15.00 Hz … 50.00 kHz ±(0.04 % of reading + 4 digits)
Frequency of digital equipment 5.00 Hz … 1.000 MHz ±(0.004 % of reading + 4 digits)
Frequency of digital equipment 5.00 Hz … 1.000 MHz ±(0.004 % of reading + 4 digits)
STANDARD SET: from ±(0.8 % of reading + 3 digits)
STANDARD SET: Capacitance 60.00 nF … 25.00 mF from ±(0.8 % of reading + 3 digits)
to ±(6.5 % of reading + 5 digits)
Capacitance 60.00 nF … 25.00 mF
to ±(6.5 % of reading + 5 digits)
• Multimeter MD 9050 with rubber holster Temperature -50 °C … +1000 °C ±(0.3 % of reading +2 °C) • Multimeter MD 9040 with rubber holster Power supply 9 V battery (NEDA1604G, JIS006P, or IEC6F22)
• Test lead with probe, 2 pcs Power supply 9 V battery (NEDA1604G, JIS006P, or IEC6F22) • Test lead with probe, 2 pcs
• Thermocouple probe, type K Overvoltage category CAT IV / 1000 V Overvoltage category CAT IV / 1000 V
• 9 V battery • 9 V battery
Dimensions 208 x 103 x 64.5 mm Dimensions 208 x 103 x 64.5 mm
• Instruction manual • Instruction manual
• Warranty Weight 635 g • Warranty Weight 635 g
MD 9035 Automotive Multimeter Designed to Work On Real-World Car Signals MD 9030 TRMS General Purpose Digital Multimeter
Metrel MD 9035 is a unique automotive multimeter top class with many exciting features, such as: Selectable 4-stroke, The MD 9030 TRMS digital multimeter has been designed for use both in the laboratories and in the harsh industrial main-
4-DIS/2-stroke, & 2-DIS engine RPM; Selectable Trig (+) / Trig- on % & ms readings; Selectable Sensitivity-Levels on RPM, tenance and repair sector. TRMS functionality makes the multimeter suitable for a multitude of situations, while the large
Dwell, % & ms readings, BeepJack warning, Backlit display and Display hold. MD 9035 is also equipped with automatic bright screen with backlight and incorrect lead connection alert make it ideal for working in dark areas.
range selection and extra fast analog bar-graph.
MEASURING FUNCTIONS:
MEASURING FUNCTIONS: • TRMS AC, DC voltage measurement;
• TRMS AC, DC current measurement;
• AC, DC voltage measurement; • Capacitance measurement;
• AC, DC current measurement; • Resistance measurement;
• Capacitance measurement; • Diod test;
• Resistance measurement; • Frequency measurement;
• Continuity test (acoustic signalling);
• Diode test;
• Temperature measurement.
• Both IP (inductive) & IG (contact) RPM;
• ms Fuel-injection on time;
• % Duty cycle; KEY FEATURES:
• Dwell angle;
• TRMS: accurate readings on sinusoidal
• Line-Level Hz (ACV, DCV); and non-sinusoidal signals.
• Frequency measurement; • Temperature measurement: meas-
• Continuity test (acoustic signaling); ures temperature in Celsius up to 300
• Electric field detection; °C and in Fahrenheit up to 572 °F.
• Temperature measurement. • Frequency measurement: up to 1 MHz.
• Lead alert: incorrect lead connection alert.
• Auto-ranging: user can switch be-
tween auto and manual ranging.
KEY FEATURES: • Relative zero mode: relative function
• Line-Level: measures frequency from for comparing the difference between
signals or removing background noise.
10 Hz to 50 kHz. • Data Hold: data hold feature freezes
• Auto-ranging: user can switch be- TECHNICAL SPECIFICATION: the display for later view.
tween auto and manual ranging. • MAX Hold: MAX hold feature freezes
• Hold: data hold function freezes the the maximum measured value.
Function Range Accuracy • Safe: CAT IV / 300 V, CAT III / 600 V and
display for later view. From ±(0.4% of reading + 3 digits)
DC Voltage 60.00 mV … 1000 V to ±(0.7% of reading + 3 digits) CAT II / 1000 V overvoltage protection.
• Pickup clip: Inductive pickup clip ac- • Backlight: large bright 3-3/4 digits,
AC Voltage 60.00 mV … 1000 V From ±(2.0% of reading + 5 digits)
cessory for IP-RPM Function. (50 Hz … 500 Hz) to ±(2.2% of reading + 5 digits) 4000 counts LCD display with back-
• 4 Selectable Trigger-Levels: For IP- DC Current 600.0 µA … 10.00 A From ±(0.7% of reading + 3 digits) light for working in dark conditions.
to ±(0.5% of reading + 3 digits)
RPM, IG-RPM, Dwell, %-Duty and ms AC Current From ±(2.2% of reading + 5 digits)
(50 Hz … 500 Hz) 600.0 µA … 10.00 A to ±(1.2% of reading + 5 digits)
Functions.
• Selectable Trigger: Positive (+) or Diode Test 1.000 V ±(1.0% of reading + 3 digits) APPLICATION: TECHNICAL SPECIFICATION:
Open-circuit voltage < 1.6 V DC, Test current 0.50 mA
Negative (-) Trigger for %-Duty and ms Resistance 600.0 Ω … 60.00 MΩ From ±(0.5% of reading + 6 digits) • Mid level electrical testing;
Functions. to ±(1.5% of reading + 5 digits) • Mid level electronic fault finding;
Capacitance 6.000 µF…2000 µF From ±(2.0% of reading + 5 digits) Function Range Accuracy
• Selectable Cylinders: 1, 2, 3, 4, 5, 6, to ±(4.0% of reading + 5 digits) • Field servicing;
8, 10 or 12 Cylinders for Dwell and IG- Temperature -50 °C…1000 °C ±(0.5% of reading + 3 digits) • General purpose. from ±(0.3 % of reading + 4 digits)
-58 °F…1832 °F ±(0.5% of reading + 6 digits) DC voltage 400.0 mV … 1000 V
RPM functions. to ±(1.0 % of reading + 4 digits)
RPM 4 (240…20000 RPM)
• Safe: CAT II / 1000 V, overvoltage pro- IP-RPM RPM 2 (120…10000 RPM) ±(2RPM) TRMS AC voltage from ±(1.5 % of reading + 5 digits)
STANDARD SET: 400.0 mV … 1000 V
tection. RPM 2M (60…5000 RPM) (50 … 500 Hz) to ±(4.0 % of reading + 5 digits)
RPM 4 (60…20000 RPM)
IG-RPM RPM 2 (30…10000 RPM) ±(2RPM) • Multimeter MD 9030 with rubber holster from ±(1.2 % of reading + 3 digits)
DC current 400.0 µA … 10.00 A
RPM 2M (15…5000 RPM) • Test lead with probe, 2 pcs to ±(2.0 % of reading + 5 digits)
APPLICATION: Dwell 0.0 °... 360.0 ° ±(1.2 °/krpm + 1 digit) • 1.5 V battery, type AAA, 2 pcs from ±(1.5 % of reading + 4 digits)
0.0 % …100.0 % ±(0.04% /krpm /cyl + 2 digits) • Instruction manual TRMS AC current 400.0 µA … 10.00 A
PFI / Multi Point Injection to ±(2.0 % of reading + 6 digits)
• Automotive industry; • Warranty
0.05 ms … 250.0 ms ±(0.05 ms + 1 digit) Diode test Open-circuit voltage <1.6 VDC, Test current 0.25 mA
• High level industrial testing;
• High level electronic fault finding; Fuel injection-ms detector 0.0 % ... 100.0 %
TBI / Single Point Injection
±(0.04 % /krpm + 2 digits)
from ±(0.6 % of reading + 4 digits)
Resistance 400.0 Ω … 40.00 MΩ
• Field servicing. 0.05 ms ... 250.0 ms ±(0.05 ms + 1 digit) to ±(2.0 % of reading + 4 digits)
0.0 % ... 100.0% ±(0.04 % /krpm /cyl + 2 digits) Temperature -20 °C … 300 °C ±(2.0 % of reading + 3 °C)
Function Range Sensitivity Accuracy
(Sin RMS) Frequency 50.00 Hz … 1.000 MHz ±(0.5 % of reading + 4 digits)
STANDARD SET: 6V 10 Hz…10 kHz 0.5 V
Capacitance 500.0 nF … 3000 µF ±(3.5 % of reading + 6 digits)
Hz (Line-level) ∞ 60 V 10 Hz…50 kHz 5 V ±(0.1 %
• Multimeter MD 9035 with rubber holster ACV & DCV 600 V 50 V + 3 digits) Power supply 2 x 1.5 V batteries, type AAA
• Test lead with probe, 2 pcs 1000 V 45 Hz…1 kHz 500 V
• Thermocouple probe, type K Power supply 2 x 1.5 V batteries, type AAA Overvoltage category CAT IV / 300 V; CAT III / 600 V; CAT II / 1000 V
• Inductive pickup clip
• 1.5 V battery, type AAA, 2 pcs Overvoltage category CAT II / 1000 V Dimensions 198 x 97 x 55 mm
• Instruction manual Dimensions 161 x 80 x 50 mm
• Warranty Weight 340 g Weight 396 g
MD 9020 General Purpose Digital Multimeter MD 9016 Electrical Field Service Multimeter
The MD 9020 is a high-quality digital multimeter, designed for everyday use in the laboratory and for maintenance and The digital multimeter MD 9016 is a perfect combination of size, Innovative functions and built-in PC communication. It
repair work in the field and in the industrial sector as well. is capable to detect and diagnose most electrical and electrotechnical problems. Display with large easy-to-read figures
and one-handed operation make MD 9016 an extremely easy-to-use. This compact instrument combines a high level of
functionality and small size and portability.
MEASURING FUNCTIONS:
• AC, DC voltage measurement; MEASURING FUNCTIONS:
• AC, DC current measurement;
• AC, DC voltage measurement;
• Capacitance measurement; • AC, DC current measurement;
• Resistance measurement; • Capacitance measurement;
• Diod test; • Resistance measurement;
• Frequency measurement; • Diode test;
• Frequency measurement;
• Continuity test (acoustic signalling); • Continuity test (acoustic signaling);
• Temperature measurement. • Electric field detection;
• Temperature measurement.
KEY FEATURES:
• Temperature measurement: meas- KEY FEATURES:
ures temperature in Celsius up to 300 • Auto-ranging: user can switch be-
°C and in Fahrenheit up to 572 °F. tween auto and manual ranging.
• Frequency measurement: up to 1 MHz. • EF detection: non-contact and probe
• Lead alert: incorrect lead connection alert. contact electric field detection.
• Auto-ranging: user can switch be- • Relative zero mode: relative function
tween auto and manual ranging. for comparing the difference between
• Relative zero mode: relative function signals or removing background noise.
• Hold: data hold function freezes the
for comparing the difference between
display for later view.
signals or removing background noise. • PC Link: test results can be download-
• Data Hold: data hold feature freezes ed to the computer via the optional PC
the display for later view. software.
• MAX Hold: MAX hold feature freezes • Safe: CAT II / 1000 V, CAT III / 600 V and
the maximum measured value. CAT IV / 300 V overvoltage protection.
• Safe: CAT IV / 300 V, CAT III / 600 V and
CAT II / 1000 V overvoltage protection.
APPLICATION:
• HVAC (heating, ventilation and air con-
APPLICATION: ditioning) troubleshooting;
TECHNICAL SPECIFICATION: • Low level electrical testing; TECHNICAL SPECIFICATION:
• Mid level electrical testing; • Low level electronic fault finding;
• Mid level electronic fault finding; • Basic field servicing;
• Field servicing; Function Range Accuracy • Hobby work. Function Range Accuracy
• General purpose. from ±(0.3 % of reading + 4 digits) from ±(0.4% of reading + 5 digits)
DC voltage 400.0 mV … 1000 V DC Voltage 60.00 mV … 1000 V
to ±(1.0 % of reading + 4 digits) to ±(0.2% of reading + 3 digits)
STANDARD SET: AC Voltage (50 Hz … 500 Hz) 60.00 mV … 1000 V ±(1.0% of reading + 5 digits)
from ±(1.5 % of reading + 5 digits)
STANDARD SET: AC voltage (50 … 500 Hz) 400.0 mV … 1000 V from ±(0.5% of reading + 5 digits)
to ±(4.0 % of reading + 5 digits) • Multimeter MD 9016 with rubber holster DC Current 600.0 µA … 8.00 A
to ±(1.8% of reading + 6 digits)
• Multimeter MD 9020 with rubber holster from ±(1.2 % of reading + 3 digits) • Test lead with probe, 2 pcs AC Current from ±(1.0% of reading + 3 digits)
DC current 400.0 µA … 10.00 A 600.0 µA … 8.00 A
• Test lead with probe, 2 pcs to ±(2.0 % of reading + 5 digits) • Thermocouple probe, type K (50 Hz … 400 Hz) to ±(1.8% of reading + 6 digits)
• 1.5 V battery, type AAA, 2 pcs from ±(1.5 % of reading + 4 digits) • 1.5 V battery, type AAA, 2 pcs Diode Test 1.000 V ±(1.0% of reading + 3 digits)
• Instruction manual AC current 400.0 µA … 10.00 A • Instruction manual
to ±(2.0 % of reading + 6 digits) Open-circuit voltage < 1.8 V DC, Test current 0.56 mA
• Warranty Diode test Open-circuit voltage <1.6 VDC, Test current 0.25 mA • Warranty from ±(0.5% of reading + 4 digits)
Resistance 600.0 Ω … 60.00 MΩ
to ±(1.2% of reading + 4 digits)
from ±(0.6 % of reading + 4 digits)
Resistance 400.0 Ω … 40.00 MΩ from ±(1.5% of reading + 5 digits)
to ±(2.0 % of reading + 4 digits) Capacitance 60.00 nF … 3000 µF
to ±(2.0% of reading + 5 digits)
Temperature -20 °C … 300 °C ±(2.0 % of reading + 3 °C) -50 °C … 1000 °C ±(0.3% of reading + 3 digits)
Temperature
Frequency 50.00 Hz … 1.000 MHz ±(0.5 % of reading + 4 digits) -58 °F … 1832 °F ±(0.3% of reading + 6 digits)
Capacitance 500.0 nF … 3000 µF ±(3.5 % of reading + 6 digits) Frequency of digital equipment 5.00 Hz … 1.000 MHz ±(0.003% of reading + 2 digits)
Power supply 2 x 1.5 V batteries, type AAA Mains frequency 10 Hz … 50 kHz ±(0.003% of reading + 3 digits)
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V; CAT III / 600 V; CAT II / 1000 V
Overvoltage category CAT IV / 300 V; CAT III / 600 V; CAT II / 1000 V
Dimensions 198 x 97 x 55 mm Dimensions 161 x 80 x 50 mm
Weight 396 g Weight 340 g
MD 9015 Electrical Field Service Digital Multimeter MD 9010 General Purpose Autocheck Digital Multimeter
The digital multimeter MD 9015 includes all necessary functions required to detect and diagnose most electrical and elec- The MD 9010 is one of the smallest and lightest of our digital multimeters. The MD 9010 unit can be used for a wide vari-
trotechnical problems. Display with large easily-read figures and one-handed operation make MD 9015 an extremely easy ety of applications. The high accuracy, LCD display and features including non-contact voltage detection and an autocheck
to use. This compact instrument combines a high level of functionality and small size and portability. function make the multimeter extremely versatile and great value for money.
APPLICATION:
APPLICATION:
• HVAC (heating, ventilation and air con- TECHNICAL SPECIFICATION:
ditioning) troubleshooting; • Low level electrical testing;
• Low level electrical testing; • Low level electronic fault finding;
• Low level electronic fault finding; Function Range Accuracy
• Basic field servicing; TECHNICAL SPECIFICATION:
• Basic field servicing; from ±(0.3 % of reading + 4 digits)
• Hobby work. DC voltage 250.0 mV … 1000 V • Hobby work.
to ±(1.0 % of reading + 4 digits)
from ±(1.0 % of reading + 3 digits) Function Range Accuracy
AC voltage (50 … 500 Hz) 250.0 mV … 750 V
to ±(2.2 % of reading + 6 digits) STANDARD SET: from ±(0.5 % of reading + 3 digits)
STANDARD SET: DC voltage 6.000 V … 600.0 V
from ±(0.8 % of reading + 3 digits) to ±(2.0 % of reading + 5 digits)
DC current 250.0 µA … 10.00 A • Multimeter MD 9010 with rubber holster
• Multimeter MD 9015 with rubber holster to ±(2.0 % of reading + 6 digits) AC voltage (50 … 60 Hz) 6.000 V … 600.0 V ±(1.5 % of reading + 5 digits)
• Test lead with probe, 2 pcs • Test lead with probe, 2 pcs
from ±(1.0 % of reading + 4 digits) 400.0 µA ±(1.5 % of reading + 3 digits)
• 1.5 V battery, type AAA, 2 pcs AC current 250.0 µA … 10.00 A • Battery DC current
to ±(2.5 % of reading + 5 digits) 2000 µA ±(1.2 % of reading + 3 digits)
• Instruction manual • Instruction manual
Diode test Open-circuit voltage <1.8 VDC, Test current 1 mA 400.0 µA ±(2.0 % of reading + 3 digits)
• Warranty • Warranty AC current
from ±(0.4 % of reading + 2 digits) 2000 µA ±(1.5 % of reading + 3 digits)
Resistance 250.0 Ω … 25.00 MΩ
to ±(1.0 % of reading + 4 digits) Diode test Open-circuit voltage <1.6 VDC
Temperature -20 °C … 300 °C 3 °C + 3 digits from ±(1.0 % of reading + 4 digits)
Resistance 600.0 Ω … 6.000 MΩ
Frequency 30 Hz … 200 kHz ±(0.05 % of reading + 4 digits) to ±(2.0 % of reading + 6 digits)
Frequency 10.00 Hz … 30.00 kHz ±(0.5 % of reading + 4 digits)
from ±(1.0 % of reading + 4 digits)
Capacitance 2.500 nF … 25.00 µF Capacitance 100.0 nF … 2000 µF ±(3.5 % of reading + 6 digits)
to ±(6.0 % of reading + 45 digits)
Power supply 2 x 1.5 V batteries, type AAA Power supply 3 V button battery (IEC-CR2032)
Overvoltage category CAT IV / 300 V; CAT III / 600 V; CAT II / 1000 V Overvoltage category CAT III / 300 V; CAT II / 600 V
Dimensions 160 x 82 x 48 mm Dimensions 113 x 53 x 10.2 mm
Weight 345 g Weight 78 g
Part No.: MD 9270 MD 9250 NEW MD 9240 MD 9235 NEW MD 9230 MD 9225 NEW MD 9220 MD 9210
True RMS −
DC current range − 2000 A − − 1000 A 400 A − −
Basic accuracy (%) − 2.0 − − 1.5 1 − −
AC current range 150 A 2000 A 1000 A 600 A 800 A 400 A 2000 A 600 A
Basic accuracy (%) 0.8 2.0 1 1 1.5 1 1.5 1.5
DC voltage range − 1000 600 V 600 V 600 V 600 V 600 V 600 V
Basic accuracy (%) − 0.5 0.5 0.5 0.3 0.3 0.5 0.3
AC voltage range 600 V 1000 600 V 600 V 600 V 600 V 600 V 600 V
Basic accuracy (%) 0.5 1.2 0.5 0.5 1 1 1.5 1.5
Resistance range − 40.00 MΩ 999.9 Ω 999.9 Ω 40.00 MΩ 40.00 MΩ 6.000 MΩ 40.00 MΩ
Basic accuracy (%) − 0.5 1 1 0.6 0.8 1 0.6
Acoustic continuity test −
Diode test − − −
Capacitance measurement − − −
Frequency measurement − −
Temperature measurement (Type K probe) − − − − −
Autocheck® V-Ω − Auto V-A − − Auto V-A −
Variable frequency drive − − − − − − −
Lo-Z (low input impedance) − − − − − − −
Power measurement (W, VA, VAR) − − − − −
3-Phase Power measurement 3-wire/4-wire − −
Count 3000 6000 4000, 6000, 9999 6000 4000 4000 6000 4000
Backlight −
COM port (data transfer) − − − − −
Automatic and manual range selection Auto Auto Auto Auto Auto
Automatic switch off −
Non-contact electrical field detection − − − − − −
MAX hold − − −
Peak value − − − −
Data hold
Relative value − − −
Jaw opening 31 mm 55 mm 45 mm 26 mm 50 mm 26 mm 45 mm 26 mm
CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V CAT IV / 300 V
Overvoltage category CAT IV / 1000 V
CAT III / 600 V CAT III / 600 V CAT III / 600 V CAT III / 600 V CAT III / 600 V CAT III / 600 V CAT III / 600 V
Dimensions (mm) 212 x 59 x 37 264 x 97 x 43 224 x 78 x 40 189 x 78 x 40 227 x 78 x 40 188 x 63 x 40 224 x 78 x 40 190 x 63 x 32
Weight (g) 225 608 224 192 290 192 220 139
CE mark
MD 9270 Leakage Clamp TRMS Meter with Power Functions MD 9250 Industrial TRMS AC/DC CAT IV /1000 V
The MD 9270 is a unique earth leakage clamp meter. It not just has the ability to accurately read the TRMS AC leakage The MD 9250 is the first Clamp Meter that meets overvoltage category CAT IV 1000 V. MD 9250 is a high quality clamp
current of a system, it can also detect losses in the system and suggest possible reasons for the loss. The voltage, power, meter specially designed for single-hand operation, built-in measuring functions; TRMS AC/DC (current, voltage), capaci-
tance, temperature and full range resistance makes this instrument an ideal tool for the most demanding applications in
harmonic, power factor (PF), total harmonic distortion (THD) and crest factor measurements make this instrument suitable the industrial sector. The large jaws capacity of (max. 55 mm) in diameter allows AC/DC - current measurements up to 2000
for any electrician and engineer. A. High resolution and accuracy, 2-line LCD display fast data acquisition and transfer (via optical interface), non-contact
voltage detection, and auto-check function are highlights of the instrument.
MD 9240 TRMS Power Clamp Meter MD 9235 TRMS Power Clamp Meter, 3-Phase, Unbalanced-Load
The MD 9240 is a high-quality and extremely easy to handle power clamp meter. The MD 9240 enables TRMS AC current The MD 9235 is a Slim-Jaw current clamp meter with ability to measure 3-Phase Unbalanced-Load + kWHr recording. The
measurement up to 1000 A, AC and DC voltage measurement, single-phase power analysis, temperature measurement MD 9235 enables TRMS AC current measurement up to 600 A, single and 3-phase power analysis, total power factor and
and more. As a result the current clamp meter is suitable for maintenance and checking of distribution systems, switch- resistance measurement. Display with large easy-to-read figures and one-handed operation make MD 9235 an extremely
boards and motors or systems where the supply network is heavily contaminated with harmonics. easy-to-use. This compact instrument combines a high level of functionality, small size and portability. All built-in features
make MD 9235 a perfect tool for advanced Power applications.
MEASURING FUNCTIONS:
• TRMS AC, DC voltage measurement; MEASURING FUNCTIONS:
• TRMS AC current measurement; • TRMS AC, DC voltage measurement;
• Frequency measurement; • TRMS AC current measurement;
• Resistance measurement; • Resistance measurement;
• Continuity test; • Frequency measurement;
• Temperature measurement; • Continuity test (acoustic signaling);
• Power parameters measurement. • Power parameters measurement.
MD 9230 Industrial TRMS AC/DC Current Clamp Meter MD 9225 Most Complete Industrial TRMS AC/DC Current Clamp Meter
The MD 9230 is a universal current clamp for measuring DC and TRMS AC voltages up to 600 V and DC and TRMS AC cur- The MD 9225 is a versatile current clamp meter with perfect combination of size and built-in functions. It measures AC/DC
rents up to 1000 A. With a broad spectrum of measuring functions and features, it is an ideal tool for service companies current and voltage, capacitance, temperature, full range resistance and captures In-rush current. Display with large easy-to-
and works electricians in the industrial sector. read figures and one-handed operation make MD 9225 an extremely easy-to-use. This compact instrument combines a high
level of functionality, small size and portability. All built-in features make MD 9225 a perfect tool for advanced applications.
MEASURING FUNCTIONS:
MEASURING FUNCTIONS:
• TRMS AC, DC voltage measurement;
• TRMS AC, DC current measurement; • TRMS AC, DC voltage measurement;
• TRMS AC, DC current measurement;
• Resistance measurement; • Capacitance measurement;
• Continuity testing; • Resistance measurement;
• Capacitance measurement; • Diode test;
• Diod test. • Frequency measurement;
• Continuity test (acoustic signaling);
• Temperature measurement.
KEY FEATURES:
KEY FEATURES:
• TRMS: accurate measurements on si-
nusoidal and non-sinusoidal signals. • Clamp on + Full Multimeter ranges:
• Jaw size: 50 mm. measures current up to 400 A AC/DC.
• Jaw size: 26 mm.
• High current: measures up to 800 A AC • In-rush: fast 30 ms Crest-MAX mode
and 1000 A DC. to capture in-rush currents.
• Auto-ranging: user can switch be- • Temperature: measures temperature
tween auto and manual ranging. in Celsius up to 537 °C and in Fahren-
• Relative zero mode: relative function heit up to 999 °F.
• Transient protection: it protects user
for comparing the difference between in case of lightning strike or switching
signals or removing background noise. surge up to 6.5 kV.
• Data Hold: data hold feature freezes • High resolution: 4000 counts enable
the display for later view. fast measurements.
• MAX Hold: MAX hold feature freezes • Relative zero mode: relative function
for comparing the difference between
the maximum measured value. signals or removing background noise.
• Display: easy to read LCD screen, 3-3/4 • Hold: data hold function freezes the
digits, 4000 counts with backlight. display for later view.
• Safe: CAT IV / 300 V, CAT III / 600 V
overvoltage protection.
APPLICATION:
• Solar and wind power systems testing; APPLICATION:
• UPS systems testing;
• Solar and wind power system testing;
• Utility scale battery systems testing; TECHNICAL SPECIFICATION: • UPS system testing; TECHNICAL SPECIFICATION:
• High level industrial testing; • Utility scale battery system testing;
• High current electrical testing. • Working in small enclosures.
Function Range Accuracy Function Range Accuracy
400.0 mV, ±(0.3 % of reading + 3 digits) From ±(0.3% of reading + 3 digits)
DC Voltage 400.0 mV … 600 V
STANDARD SET: DC voltage 4.000 V, 40.00 V, 400.0 V, ±(0.5 % of reading + 3 digits) to ±(1.0% of reading + 4 digits)
600.0 V ±(1.0 % of reading + 4 digits)
STANDARD SET:
AC Voltage From ±(1.0% of reading + 4 digits)
• Current clamp MD 9225 4.000 V … 600 V
• Current clamp MD 9230 AC voltage (50 Hz … 500 Hz) to ±(2.0% of reading + 4 digits)
• Test lead with probe, 2 pcs 50 Hz … 500 Hz 400.0 mV ±(4.0 % of reading + 4 digits) • Test lead with probe, 2 pcs From ±(1.0% of reading + 4 digits)
• 1.5 V battery, type AAA, 2 pcs 50 Hz … 60 Hz 4.000 V, 40.00 V, 400.0 V ±(1.0 % of reading + 4 digits) • Thermocouple probe, type K DC Current 0.0 A … 400.0 A
to ±(2.5% of reading + 5 digits)
• Pouch 60 Hz … 500 Hz 4.000 V, 40.00 V, 400.0 V ±(1.5 % of reading + 4 digits) • Pouch
• 1.5 V battery, type AAA, 2 pcs AC Current From ±(1.0% of reading + 6 digits)
• Instruction manual 50 Hz … 500 Hz 600 V ±(2.0 % of reading + 4 digits) 0 A … 400 A
• Instruction manual (40 Hz … 400 Hz) to ±(2.5% of reading + 5 digits)
• Warranty from ±(1.5 % of reading + 4 digits) Diode Test Open-circuit voltage < 1.6 V DC, Test current 0.4 mA
DC current 400.0 A,1000 A • Warranty
to ±(5.0 % of reading + 30 digits)
From ±(0.8% of reading + 6 digits)
from ±(1.5 % of reading + 4 digits) Resistance 400.0 Ω ... 40.00 MΩ
AC current (15 Hz … 1 kHz) 400 A, 800 A to ±(2.0% of reading + 4 digits)
to ±(5.0 % of reading + 30 digits)
Capacitance 500.0 nF … 3000 µF ±(3.5% of reading + 6 digits)
from ±(0.6 % of reading + 4 digits)
Resistance 400.0 Ω … 40.00 MΩ From ±(2.0% of reading + 3 digits)
to ±(2.0 % of reading + 4 digits) -20 °C … 537 °C
to ±(3.0% of reading + 3 digits)
Continuity test 400.0 Ω ±(1.5 % of reading + 6 digits) Temperature
From ±(2.0% of reading + 6 digits)
Diode test Open-circuit voltage <1.6 VDC, test current 0.4 mA -4 °F … 1000 °F
to ±(3.0% of reading + 6 digits)
Capacitance 500 nF … 3000 µF ±(3.5 % of reading + 6 digits) Mains frequency 5 Hz …100 kHz ±(0.5% of reading + 4 digits)
Power supply 2 x 1.5 V batteries, type AAA Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 300 V; CAT III / 600 V Overvoltage category CAT IV / 300 V, CAT III / 600 V
Dimensions 227 x 78 x 40 mm Dimensions 188 x 63 x 40 mm
Weight 290 g Weight 218 g
The MD 9220 is a high-quality TRMS current clamp meter, designed for everyday use in the laboratories and for mainte- Versatility, sturdy case, high accuracy and lots of measurement functions are key features of the current clamp MD 9210.
nance and repair work in the field and in the industrial sector. This universal current clamp offers good value for money.
MEASURING FUNCTIONS:
MEASURING FUNCTIONS:
• TRMS AC, DC voltage measurement;
• TRMS AC current measurement; • AC, DC voltage measurement;
• Frequency measurement; • AC current measurement;
• Resistance measurement; • Frequency measurement;
• Continuity testing; • Resistance measurement;
• Capacitance measurement; • Continuity testing;
• Diod test; • Capacitance measurement;
• Electric field detection. • Diod test.
APPLICATION: APPLICATION:
• High powered 3-phase machinery testing; • Working in small enclosures;
TECHNICAL SPECIFICATION:
• High level industrial testing; • General purpose;
• High current electrical testing. • 3-phase machinery testing. TECHNICAL SPECIFICATION:
Function Range Accuracy
6.000 V ±(0.5 % of reading + 3 digits)
STANDARD SET: DC voltage 60.00 V ±(1.0 % of reading + 5 digits) STANDARD SET: Function Range Accuracy
600.0 V ±(2.0 % of reading + 5 digits) 400.0 mV ±(0.3 % of reading + 4 digits)
• Current clamp MD 9220 • Current clamp MD 9210
6.000 V, 60.00 V ±(1.5 % of reading + 5 digits) DC voltage 4.000 V, 40.00 V, 400.0 V ±(0.5 % of reading + 3 digits)
• Test lead with probe, 2 pcs AC voltage (50, 60 Hz) • Test lead with probe, 2 pcs
600.0 V ±(2.0 % of reading + 5 digits) 600 V ±(1.0 % of reading + 4 digits)
• 1.5 V battery, type AAA, 2 pcs • 3 V battery
6.000 V, 60.00 V ±(2 % of reading + 5 digits) 4.000 V, 40.00 V, 400.0 V ±(1.5 % of reading + 5 digits)
• Pouch AC voltage (50 … 500 Hz) • Pouch AC voltage (50 Hz … 500 Hz)
600.0 V ±(2.5 % of reading + 5 digits) 600 V ±(2.0 % of reading + 5 digits)
• Instruction manual • Instruction manual
• Warranty AC current (50, 60 Hz) 400.0 A, 2000 A ±(1.5 % of reading + 5 digits) AC current (50 / 60 Hz) 40.00 A, 400.0 A, 600 A ±(1.5 % of reading + 8 digits)
• Warranty
6.000 kΩ ±(1.2 % of reading + 6 digits) 400.0 Ω ±(0.8 % of reading + 8 digits)
Resistance 60.00 kΩ, 600.0 kΩ ±(1.0 % of reading + 4 digits) 4.000 kΩ, 40.00 kΩ, 400.0 kΩ ±(0.6 % of reading + 4 digits)
6.000 MΩ ±(2.0 % of reading + 4 digits) Resistance
4.000 MΩ ±(1.0 % of reading + 4 digits)
Continuity test 600.0 Ω ±(2.0 % of reading + 8 digits) 40.00 MΩ ±(2.0 % of reading + 4 digits)
Diode test Open-circuit voltage <1.6 VDC, test current 0.4 mA Diode test Open-circuit voltage <1.6 VDC, test current 0.25 mA
Frequency 10 Hz … 30 kHz ±(0.5% of reading + 4 digits) Frequency 10 Hz … 100 kHz ±(0.5 % of reading + 4 digits)
Capacitance 100.0 nF … 2000 µF ±(3.5% of reading + 5 digits) Capacitance 500.0 nF … 3000 µF ±(3.5 % of reading + 6 digits)
Power supply 2 x 1.5 V batteries, type AAA Power supply 3 V battery (IEC-CR2032)
Overvoltage category CAT IV / 300 V; CAT III / 600 V Overvoltage category CAT IV / 300 V; CAT III / 600 V
Dimensions 224 x 78 x 40 mm Dimensions 190 x 63 x 32 mm
Weight 220 g Weight 139 g
Selection Guide for Voltage detectors MD 1150 LCD Voltage / Continuity Tester
The MD 1150 is a high-quality voltage / continuity tester designed for the most demanding duties. With a broad spectrum
Part No.: MD 1150 MD 1050 of measurement functions and CAT IV / 1000 V overvoltage category, the device is suitable for both the industrial sector
and for everyday maintenance and repair practice.
MEASURING FUNCTIONS:
• AC, DC voltage testing;
• Phase testing;
• Rotary field testing;
AC, DC VOLTAGE TEST • Continuity testing;
Range 6 V … 1000 V 6 V … 1000 V • RCD trip-out test.
Basic accuracy (%) ±(2.0 % of reading + 4 digits) −
Operating time Max. 30 s Max. 30 s
Reaction time <1s <1s KEY FEATURES:
Frequency range 0 … 400 Hz 0 … 400 Hz • 6 V … 1000 V DC and AC voltage range.
CONTINUITY AND DIODE TEST
• Data hold function.
Indication acoustic and LCD display acoustic and LED display
• LCD display with backlight.
Resistance range 0 … 2 kΩ 0 … 500 kΩ
• Phase rotation measurement.
Test current 4 µA 400 µA
• RCD trip-out test (max. nominal differ-
RCD TRIP-OUT TEST
ential current - 30 mA).
RCD check to trip 30 mA RCD, circuit breakers to trip 30 mA RCD, circuit breakers
• Optical and acoustic continuity test.
PHASE TESTING
• Automatic switch off.
Phase test 1-pole phase test 1-pole phase test
• CAT IV / 1000 V overvoltage protection.
Phase rotation 2-pole phase rotation test 2-pole phase rotation test
Voltage display >100 VAC >100 VAC
GENERAL
Display 3 ½ digit, LCD with backlight LED bar display APPLICATION:
12 V, 24 V, 48 V, 120 V, 230 V, 400 V, 690 V,
Ranges 6 V … 1000 V • Mid level electrical testing;
1000 V
Overvoltage category CAT IV / 1000 V CAT IV / 1000 V • Mid level electronic fault finding;
IEC/EN 61243-3, DIN VDE 0682-401, IEC/EN 61243-3, DIN VDE 0682-401, • Field servicing;
Standards
IEC61010, GS38 IEC 61010, GS38 • General purpose.
Power supply 2 x 1.5 V batteries, type AAA 2 x 1.5 V batteries, type AAA
Weight 200 g 200 g
Dimensions 238 x 70 x 30 mm 238 x 70 x 30 mm
STANDARD SET:
• Voltage tester MD 1150
• 1.5 V battery, type AAA, 2 pcs TECHNICAL SPECIFICATION:
• Captive test probe protection
• Plastic probe guard (in accordance Function Range
with GS38) Nominal voltage range 6 V … 1000 V (automatic range selection)
• Instruction manual Frequency range 0 … 400 Hz
• Warranty Resistance range 0 … 2 kΩ
RCD test current 30 mA
Phase indication >100 VAC
Phase rotation determination 100 V … 1000 V, 2-pole
Reaction time < 0.1 s
Display 3-1/2 digit LCD display with backlight
Power supply 2 x 1.5 V batteries, type AAA
Overvoltage category CAT IV / 1000 V
Dimensions 238 x 70 x 30 mm
Weight 200 g
MD 1050 LED Voltage / Continuity Tester MD 115 Non Contact Voltage Detector MD 105 Non Contact Voltage Detector
The MD 1050 is a multifunction voltage / continuity tester. Because of it’s broad spectrum of measurement functions, it is The MD 115 is a non-contact voltage tester that features a The MD 105 is a basic non-contact voltage tester that fea-
suitable for use both in the home and in trade and industrial sectors. visual display, vibrating indicator and comes complete with tures a visual display indicator and comes complete with a
a pocket clip. It is easy to operate and can be used for a pocket clip. The contact-less MD 105 voltage tester can, for
wide variety of jobs; this is an essential tool for both home example, detect live wires in splices, cable drums, socket
handymen and professionals. The tester can detect an in- outlets and switches. A defective lamp in a chain of lights
MEASURING FUNCTIONS: visible break within an extension cable with an accuracy of can be localized within seconds. An invisible cable break-
just a few millimeters. A defective bulb in a chain of lights age in an extension lead is indicated to within a tolerance
• AC, DC voltage testing;
can be located within seconds. Live-voltage wires (e.g., in of just a few millimeters. The Metrel MD 105 uses a capaci-
• Phase testing; cable plugs, cable drums, sockets, switches and junction tive measuring process. In contrast to inductive measure-
• Rotary field testing; boxes) can also be quickly detected. ments, no flow of current is required.
• Continuity testing;
• RCD trip-out test. MEASURING FUNCTIONS: MEASURING FUNCTIONS:
• Non contact voltage detection from 12 V AC; • Non contact voltage detection from 110 V AC;
• High performance LED flashlight;
• Vibration alert in case of power.
STANDARD SET:
STANDARD SET:
APPLICATION: • Non Contact Voltage Detector MD 115
• Non Contact Voltage Detector MD 105
• 1,5 V battery test, type AAA, 2 pcs • 1,5 V battery test, type AAA, 2 pcs
• General purpose; • Instruction manual • Instruction manual
• Electrical testing. • Warranty • Warranty
STANDARD SET:
TECHNICAL SPECIFICATION:
• Voltage tester MD 1050
• 1.5 V battery, type AAA, 2 pcs
Function Range
• Captive test probe protection
10 red LEDs for voltage, continuity,
• Plastic probe guard (in accordance with Display
polarity and phase rotation measurement
GS38)
12 V, 24 V, 48 V, 120 V, 230 V, 400 V, 690 V, 1000 V
• Instruction manual Nominal voltage range
(automatic range selection)
• Warranty Frequency range 0 … 400 Hz TECHNICAL SPECIFICATION: TECHNICAL SPECIFICATION:
Resistance range 0 … 500 kΩ
RCD test current 30 mA Function Range Function Range
Phase indication >100 VAC Display Visual, vibration Display Visual, vibration
Measurement range 12 … 1000 V AC Measurement range 110 … 1000 V AC
Phase rotation determination 100 V … 1000 V, 2-pole
Integrated LED flash light Yes Integrated LED flash light Yes
Reaction time < 0.1 s
Power supply 2 x 1,5 V batteries, type AAA Power supply 2 x 1,5 V batteries, type AAA
Power supply 2 x 1.5 V batteries, type AAA Overvoltage category CAT III / 1000 V
Overvoltage category CAT III / 1000 V
Overvoltage category CAT IV / 1000 V Degree of protection IP 40 Degree of protection IP 44
Dimensions 238 x 70 x 30 mm Dimensions 160 x 25 mm Dimensions 142 x 26 mm
Weight 200 g Weight 45 g Weight 22 g
MD 9060
MD 9050
MD 9040
MD 9240
MD 9030
MD 9020
MD 9016
MD 9015
MD 9250
MD 9235
MD 1150
MD 1050
Part
Photo
number
Description Target application Power Quality Analysis
LAN Cabling Certification
AMD Thermocouple probe,
9023 type K
Probe for contact temperature measurement. – – – – – Indoor Environment Quality
Digital Multimeters / Clamp Meters /
Adapter for
AMD Adapter is intended to connect the thermocouple
9024
thermocouple probe
AMD 9023
probe with a multimeter.
– – – – –
Voltage and Continuity Testers
Variable transformers /
PC Software for MD
AMD Basic downloading software supplied on CD and
9015 with RS232 – – – – – – – – – –
9025
cable
RS232 communication cable. Equipment for laboratories and Schools
CATALOGUE 2012/13
Option – Not available
Variable transformers / Equipment for laboratories and Schools Variable transformers / Equipment for laboratories and Schools
500
400
Standard track
Silvered track
80
40
200
20
100
METREL is well known producer of turns is small enough to avoid harmful • Battery chargers; • over current protection; cation of variable transformers in instal-
Loading versus ambient temperature
variable transformers and power sup- sparking or excessive heating of shorted • DC motor controls; In (%) 120 • avoiding corrosive, high humidity and lations with higher input voltage than
plies which are widely accepted in turns. • Plastic blow moulding machines; 100 dust places or protection against these rated. Two variable transformers of the
laboratories, industry, schools. • Control of furnace transformers; 80 environmental conditions; same type are connected in series and
The competitiveness of these products • Lightening regulation; 60
• preventing short circuits on axis; enable operation with double voltage of
Normalized voltage drop U o
is based on a good price/performance Short duration loading
Udn (%) 120
• Laboratory stirrers; 40
• appropriate design and construction of rated for one.
In (%) 600 Standard track
ratio. They are robust in construction, • AC, DC 100 brush motors; Silvered track equipment with built-in variable trans-
500 20
they have low magnetizing current, low Standard track
Silvered track
• High current
80 motorized voltage regula- formers. Dual voltage tap slides
400
operating torque and no distortion or har- tors; 60 20 30 40 50 60 70 80 90 100 Ta ( C)
o
This possibility enables generating vari-
300
monics added. Copper winding is preci- • High current plastic plating operations. able differential voltage with the same or
200
40 Venting of power devices reduces their
sion wound on a toroidal core. Tradition 20 heating and thus rated performances opposite phase related to input voltage.
100
with 50 years of experience in continu- 0.1 1 10 100 1000 t (min)
TECHNICAL PERFORMANCES: Frequency can be applied. Power lines must have Typical applications are boosting regula-
ous production, product control, testing, 20 40 60 80 100 120 Uo/Uin(%)
All METREL variable transformers are high enough cross-section, be fixed tors.
High reliability
safety, permanent improvements and, designed for operation at 50/60 Hz. They and secured with good contact to pre-
METREL variable transformers are prac-
customer service are fil rouge in the pro- may be operated at higher frequencies, vent overheating and additional voltage Shaft modifications
METREL variable transformers provide tically maintenance free. Long-life opera-
duction of METREL variable transform- tion is assured with: without derating, however regulation drops. Primary overcurrent breaking The shaft provided with each model ac-
an outputLoading
In (%) 120
voltage waveform
versus ambient temperature that is a
ers. Complete information on variable • Precision winding; becomes poorer. Units listed for 230 V device must be properly selected and commodates the METREL transformer’s
precise reproduction of the applied input
transformers and complete instrument 100
• Surface forming of winding; operations may be applied on 115 V at use of load protection fuses is recom- voltage selector knob when mounted
voltage waveform. Slider is mounted on
product groups of METREL can be found 80
• Tight tolerances in preparing sliding 25 Hz, however rated currents remain mended. Fuses / residual circuit break- on panels not exceeding the thickness
shaft but electrically insulated from it.
on www.metrel.si. 60 track; the same. ers (RCD) prevent excessive heating due shown in dimension data. Modification
With a brush holder, it serves also as a
40 • Deep varnishing and baking also for fix- to overload and prevent fire generation to the shaft, either in length or end di-
heat sink. OnlySilveredstandard
Standard track METREL vari-
METREL variable transformers are avail- 20
track ing winding structure; Linear output voltage as a result of overheating. ameter, is available for both manual and
able transformers are listed in this cata-
able as: • A spring-loaded solid carbon brush. motor-operated units.
logue. 20 30 40 50 60 70 80 90 100 Ta ( C) o METREL variable transformers have the Regardless if the variable transformers
• Single or poly phase types; advantage of providing output voltage are designed for harsh environment, it
Power factor
• Autotransformer or insulated variable Technical regulation that varies linearly in proportion to the is best for reliable operation and long Product groups
Power factor of load has very little effect
transformer; Three general regulations serve as a on the operation of a METREL variable angle of rotation of the output voltage lifetime to keep them in non-aggressive a) Open variable transformer types (sub-
• Manual or motor driven variable trans- base for function, quality and safety of transformer in the range from 0.5 lag- selector. Because of the large number environment. The axis is on one side assemblies for panel mount or other
former; METREL variable transformers: Euro- ging to 0.5 leading. Like any transform- of increments of output voltage selec- connected to metal base. If the other built-in equipment) HSG; HST; HTG;
• Open / panel mount or enclosed con- pean Low voltage directive 2006/95/ er, the METREL variable transformer tion with the slider, the output voltage is side of axis is electrically connected to HSM; HTM with Accessories (Buttons,
struction; EC (72/23/EEC), German standard VDE reflects the load power factor to the line practically steeples. the same base (through the housing), Scales, Motor drives).
• Air-cooled, optional oil-cooled variable 0552 and International standard IEC with very little change. Only for very light this will present a short circuit coil of the
transformer. 60989. loads, possibly under 10%, will the lag- transformer with increasing power con- b) Desk top variable transformer types
ging power factor of the METREL vari- Udn (%) 120
Normalized voltage drop U o
sumption, overheating, and even gen- (HSN, HTN).
Short duration loading
METREL variable transformers provide able transformer become
In (%) 600 significant due
Applications 100 erating high leakage currents and stray
to magnetizing current. 500
continuously adjustable voltage from METREL variable transformers are ap- Standard track
Silvered track
80 magnetic fields. c) Power supplies (MA 4804, MA 4852,
400
zero to 100% or 113% of the line volt- plied to various products or applications 60
It is important that the brushes are not MA 4853).
High efficiency 300
age. Their operation is simple and effi- including the following: METREL variable transformers have 40 leaving in one spot for extended peri-
200
cient. Cooper wire is wound on a toroi- • Power supplies; low electrical losses under all load con- 20 ods to avoid gradually increase contact Technical specification
100
dal core by using high precision winding • Laboratory and test equipment; ditions. Efficiency is 98.5
0.1
percent
1 10
at 100 1000 t (min)
resistance and eventual overheating and Frequency range: 50 Hz ÷ 400 Hz
120 Uo/Uin(%)
machines. Sliding trace of the winding • Speed control devices; maximum output voltage selected. This 20 40 60 80 100
damage of the variable transformer unit. Mechanical angle:
340, core size up to M200
320, other core sizes
is properly smoothed to provide low re- • Computer peripheral equipment; efficiency remains high, even at greatly Protection class: I
∆Uo/∆Uo max for autotransformer / Uo max = Uin
sistance and long wearing track for the • Welding controls; reduced load voltage. ∆Uo/∆Uo max for autotransformer / Uo max > Uin Pollution degree: 2
carbon brush. Some models are silver OPTIONS:
• Variable speed devices for large ma- Loading versus ambient temperature
∆Uo/∆Uo (at Uo = Uin) for separate secondary Protection degree: IP 20
plated, providing lower output imped- chinery; Ambient temperature
In (%) 120 ∆Uo/Uo for separate secondary
Parallel connections Altitude (operation): 2000 m
∆Uo/Uo for autotransformer / Uo max = Uin
ance. The core is made of strip-wound METREL variable transformers
100 are de- Test voltage
• Electroplating and anodising; ∆Uo/Uo for autotransformer / Uo max > Uin METREL has a solution for paralleling
signed for continuous 80operation in ambi- (input to metallic 2500 VAC RMS, 50 Hz, 2 s
oriented silicon steel for low electrical • High-voltage electronic tube circuits; two single-phase transformers. Output accessible parts):
ent of 0 °C to 40 °C,60at full rated load.
losses and high magnetic densities. The • Spare supply regulators in broadcast Installation guidelines current can be doubled by using the bal- Test voltage
4000 VAC RMS, 50 Hz, 2 s
When operated above4040 °C, the output (input/output, HST):
coil is insulated from the core by means transmitters; power must be derated in accordance Standard track For safety and reliable operation of MET- ancing choke and mechanical paralleling Operating temperature
Silvered track -5 °C ÷ 40°C
of a special insulation support that also • Voltage stabilizers; 20
with diagram 1. For example, when op- REL variable transformers the following of sliders on common shaft. range:
Operating humidity 90 % RH (40 °C),
prevents movement of coil turns. Varia- • High voltage test set; erating model HSH 230/4 requirements need to be fulfilled:
20 in
30 a40
6050°C60am- o
70 80 90 100 Ta ( C) range: non-condensing
ble transformers are wound in a manner • Meter test bench; bient, rated output current would be: 70 • good venting; Serial connections Storage temperature
-15 °C ÷ 70 °C
% x 4 A = 2.8 A. • appropriate wiring; Serial connection is intended for appli- range:
to ensure that voltage between the two • Hydro generation plants;
8. 2 8. 3
Variable transformers / Equipment for laboratories and Schools Variable transformers / Equipment for laboratories and Schools
VARIABLE TRANSFORMERS EQUIPMENT FOR LABORATORIES AND SCHOOLS
1-phase Built-in 3-phase Built-in Motor driven Desk top Power Supplies R-L-C Decade
HSG - Autotransformers HTG - Autotransformers HSM 1-phase and HTM 3-phase HSN 1-phase and HTN 3-phase MA 4804, MA 4852 and MA 4853 MA 2405, MA 2705 and MA 2115
The HSG series voltage transformers METREL three-phase transformers are METREL motor-operated units dif- The HSN and HTN series voltage trans- The MA 4804, MA 4852 and MA 4853 MA 2405 Decade capacitor is intended
are often built in test equipment or per- suitable for connection to either delta or fer from manual types primarily in the formers are fully housed, thus providing are power supply units with the built-in for all application areas where capaci-
manent installations. Output voltage is star connected incoming power sources means used to rotate the shaft to vary protection from physical accidents, and variable transformers permiting a con- tance variation/selection by hand is re-
controlled with a large, slip-protected output voltage. A synchronous motor is tinuous voltage adjustment within the quired. It is all passive electric device
or loads. They are always star connected other hazards. Generally they are used
knob. Output voltage is increased lin- used to position the slider. The motor is limits of declared specifications. housed in metallic case and with internal
and have a neutral connection accessi- reversible by means of a SPDT switch wherever adjustable AC voltage is re-
early as the knob is turned clockwise. ble. A common shaft rotates all output guarding. It consists of 3 decades for
(not supplied) and operates on 230 V, 50 quired. Output voltage is precisely con-
The user is required to add adequate The transformers have separate primary selection of the capacitance in range of
voltage sliders in parallel. / 60 Hz. Integrated limit switches pre- trolled. and secondary windings resulting in gal-
external over-current protection device 100 pF up to 100 nF. Set value is directly
vent overriding the winding edges. vanic isolation of the mains circuit from
like fuse or circuit breaker. All models visible on decade’s dials. MA 2405 Dec-
are suitable for 50 Hz / 60 Hz frequency 3-phase METREL transformers with Output voltage is controlled with a output circuit. This is frequent require-
Typical methods for controlling METREL ade Capacitor uses high quality polypro-
range. Single- and three-phase models 3-wire connection to 3-phase supply sys- large, slip-protected knob. Output volt- ment for energizing specific electrical
motor-operated units include: pylene capacitors providing accuracy of
are available with various current ratings. tem can be used to feed 3-wire, 3-phase age is increased linearly as the knob devices. 5 %.Very good DC insulation resistance
• Manual increase/decrease switch con-
Output voltage is precisely controlled. balanced loads. In this case the common is turned clockwise. All models are of the capacitors enables the application
sists of either momentary-contact push-
Autotransformer design allows optional connection (or “virtual neutral”) of the button or lever-type toggle switch. equipped with power cord, illuminated The power supply units are equipped also in DC circuits, insulation materials
voltage boost. Because of demanding METREL unit should not be used. Less • Relays and contactors control the in- on/off switch and external PE terminal with V-meter and A-meter, which allow also provide low dissipation factor at the
applications all Metrel variacs are de- than 10% of rated current of variable crease/decrease power to the motor as and optional with appropriate plug con- a permanent control over output voltage frequencies of 500 kHz and up.
signed to exhibit superior resistance transformers flowing into virtual neutral a result of low-level signals from external and current. They are overload-protected
nector. They are marked with output
to high temperature, humidity and me- would keep unbalance of three-phase circuitry. Example: photoelectric cells or with a circuit-breaker which disconnects MA 2705 Decade inductance is in-
voltage in volts (corresponding to nomi-
chanical shocks/vibrations. Used in hard- thermostat signals can provide the input. the secondary circuits when a short-cir-
output in reasonable limits. nal input voltage). tended for all application areas where
wired, permanent installations wherever • Process control instrumentation can cuit condition occurs at the output.
inductance variation/selection by hand
operational or performance points need be used for closed-loop, precise con- is required. It is passive electric device
With a three phase, 4-wire system in- They can be conveniently moved Field Application
to be varied. trol, and more sophisticated circuitry to housed in metallic case. It consists of
put, the system neutral should be solidly provide the raise-fall switching for the around laboratory, production or equip- The MA 4804, MA 4852 and MA 4853
connected to the common or “neutral” 3 decades for selection of the induct-
motor. ment service area to provide adjustable power supply units are used in electron-
Technical specification
point of the METREL unit. This will pre- ic industry (electrical and control labs), in ance in range of 0 mH up to 999 mH.Set
voltage.
1-phase: HSG 230 HSG 260
vent neutral shift and possible damage Motor operating time refers to the num- service workshops, in technical educa- value is directly visible on decade’s dials.
Input voltage: 230 V 230 V
or failure of the unit. Full-range voltage ber of seconds for the motor to traverse tion, etc., briefly everywhere adjustable MA 2705 Decade inductance uses fer-
Output voltage: 0 V ÷ 230 V 0 V ÷ 260 V All models are suitable for 50 Hz / 60 rite chokes providing accuracy of 5 % at
control cannot be obtained from a three- its full range in one direction. METREL supply voltage is needed, or where for
Current:* 1 A ÷ 32 A 0.8 A ÷ 30 A Hz frequency range. Single- and three- 50% of rated current.
phase METREL unit consisting of three transformers have standard 23 s motor technical or safety reasons the power
Power: 230 VA ÷ 7360 VA 208 VA ÷ 7800 VA operating time. Other motor operating phase models are available with various
single-phase units connected in closed supply source has to be galvanically in-
* Maximum current range depends on model type times are optional. current ratings. MA 2115 and MA 2115 S Decade resis-
delta. Outside the factory, it is not prac- sulated from the mains. Test voltage of
4 kV AC. rms between input and output tors are intended for all application areas
tical to convert multiple single-phase where resistances variation/selection by
HST - Separating transformers
Technical specification Technical specification enables using the units in CAT III / 300 V
models to balanced three-phase applica- hand are required. It is passive electric
1-phase: HSM 230 HSM 260 1-phase: HSN 260 environment.
Variable, coupled with insulation trans- tions because of associated mechanical Input voltage: 230 V 230 V Input voltage: 230 V device housed in metallic case. Each
formers are utilized for personnel safety problems. Output voltage: 0 V ÷ 230 V 0 V ÷ 260 V Output voltage: 0 V ÷ 260 V consist of 7 decades with each own ro-
Technical specification
in addition to provide variable voltages Current:* 3 A ÷ 32 A 2.5 A ÷ 30 A Current:* 4.5 A ÷ 30 A Part No. HSM 230 HSM 260 HSM 260
tary switch with range multiplier from 0
for testing purposes. In general they are Technical specification Power: 690 VA ÷ 7360 VA 650 VA ÷ 7800 VA Power: 1170 VA ÷ 7800 VA Power supply: 230 V 230 V 230 V
to 9, and ∞. Safety 4 mm sockets are
equally suitable for any of the testing, 3-phase: HTG 400 HTG 450 3-phase: HTM 400 HTM 450 3-phase: HTN 450 Output voltage:
connected to each resistance chain that
engineering or control function like or- Input voltage: 400 V 400 V Input voltage: 400 V 400 V Input voltage: 400 V AC 0 V ÷ 260 V 0 V ÷ 33 V 0 V ÷ 33 V it could be individually accessible. It is
DC 0 V ÷ 46 V 0 V ÷ 46 V
dinary variacs based on autotransformer Output voltage: 0 V ÷ 400 V 0 V ÷ 450 V Output voltage: 0 V ÷ 400 V 0 V ÷ 450 V Output voltage: 0 V ÷ 450 V also possible to split resistance chain
Permissible
design. Additionally they can isolate sen- Current:* 1 A ÷ 32 A 0.8 A ÷ 30 A Current:* 3 A ÷ 32 A 2.5 A ÷ 30 A Current:* 8 A ÷ 30 A
permanent 3.1 A 6A 6A
into two or more independent insulated
sitive equipment from interference and Power: 690 VA ÷ 22080 VA 624 VA ÷ 23400 VA Power: 2070 VA ÷ 22080 VA 1930 VA ÷ 23400 VA Power: 6240 VA ÷ 23400 VA current: groups by selection of rotary switch po-
ground noise. * Maximum current range depends on model type * Maximum current range depends on model type * Maximum current range depends on model type * Maximum current range depends on model type sition ∞.
8. 4 8. 5
METREL d.d.
Measuring and Regulation Equipment Manufacturer
Ljubljanska 77, SI-1354 Horjul
Tel: +386 (0)1 75 58 200; Fax: +386 (0)1 75 49 226
E-mail: metrel∞metrel.si; http://www.metrel.si
METREL GmbH
Metrel Mess- und Prüftechnik GmbH
Orchideenstraße 24, 90542 Eckental
Tel.: +49 9126 28996-0; Fax: +49 9126 28996-20
E-mail: metrel∞metrel; http://www.metrel.de
Metrel UK Ltd.
Test and Measuring Equipment Unit 1, Hopton House, Ripley Drive,
Normanton, West Yorkshire, WF6 1QT
Tel.: +44 (0) 1924 245 000
E-mail: info∞metrel.co.uk; http://www.metrel.co.uk
Note! Photographs in this catalogue may slightly differ from the instruments at the time of delivery.
Subject to technical change without notice.
GENERAL_2012/13_Ang_Julij