The document provides hardware requirements for an on-premise Dynamics 365 Business Central implementation including a database server with 128GB RAM and RAID storage, two or more application/web servers each with 32-64GB RAM, optional terminal servers, and client workstations. It notes the recommended configuration can support up to 100 users and provides additional implementation details.
The document provides hardware requirements for an on-premise Dynamics 365 Business Central implementation including a database server with 128GB RAM and RAID storage, two or more application/web servers each with 32-64GB RAM, optional terminal servers, and client workstations. It notes the recommended configuration can support up to 100 users and provides additional implementation details.
The document provides hardware requirements for an on-premise Dynamics 365 Business Central implementation including a database server with 128GB RAM and RAID storage, two or more application/web servers each with 32-64GB RAM, optional terminal servers, and client workstations. It notes the recommended configuration can support up to 100 users and provides additional implementation details.
Topology Cache : 30 MB Cache (or better) RAM : 128 GB (or better - must be expandable) NIC : Gigabit Ethernet Controller : Array Controller Harddisk (Enterprise SSD): OS : 2 X 400 GB, SSD – RAID 1 DB : 4 X 400 GB, SSD – RAID 10 Database Server LOG : 4 X 400 GB, SSD – RAID 10 TempDB : 2 X 400 GB, SSD – RAID 1 Backup File: 2 X 400 GB, SSD – RAID 1 OS : Windows Server 2019 / 2022 Std. or Datacenter Edition Others : SQL Server 2019 Standard or Enterprise Edition, BC code
2 (or more) Application & Web Server (Required)
CPU : Intel 6 core 2.4 Ghz (or better) Cache : 20 MB Cache (or better) Application and Web Server Application and Web Server Application and Web Server RAM : 32-64 GB (or better – must be expandable) NIC : Gigabit Ethernet Harddisk (Enterprise SSD): OS : 2 X 400 GB, SSD – RAID 1 WAN / LAN Backup : 2 X 400 GB, SSD – RAID 1 Rack Modem Software : OS : <same OS supported as Database Tier> Other : NET Framework 5.0, IIS 10, BC Code Gigabit Switch Hub 2 (or more) Terminal Server (Optional) CPU : Intel 6 core 2.4 Ghz (or better) Cache : 20 MB Cache (or better) Router RAM : 32-64 GB (or better – must be expandable) SWITCH HUB Customer Users NIC : Gigabit Ethernet Harddisk (Enterprise SSD): OS : 2 X 400 GB, SSD – RAID 1 Notes: Backup : 2 X 400 GB, SSD – RAID 1 * This recommended hardware system configuration may support up to 100 BC Named users in a typical environment. Software : * All servers are fully configured as Member Servers within the domain or Active Directory Structure. OS : <same OS supported as Database Tier> * Servers must not be Domain Controller server. Other : Web Browser, Ms. Office 2019 * Microsoft Hyper-V or VMWare Professional Edition is recommended if virtual environment is used. More details can be found in http://www.windowsservercatalog.com/svvp.aspx?svvppage=svvpwizard.htm * This configuration is assuming physical server will be used. If virtual environment is deployed then the physical server (each host) should have at Dynamics 365 Business Central Web Client least 15% of RAM resource remain unassigned. CPU : Multi-Core Processor 2.0 Ghz (or better), 2-4 Cores, * SSD Hard disk for server is preferred RAM 4 GB (or better), NIC 100/1000, HD 40 GB * Other pre-requirement for BC such as Active Directory, Antivirus , etc must be already installed on different server as needed. OS : Windows 10 Pro/Ent * If web/phone client over internet will be implemented, web server must use a dedicated server (cannot combine with Application Others : SQL Client License (On Premise), Ms. Office 365 or Server) and 3rd party SSL certificates must be provided to access BC web/phone client over the internet. In order to set up web/phone client Ms. Office 2019/2016, IIS 10 environment, customer need to have the knowledge on how to publish the website along with the security as it will go on public network (such as Internet browser as stated in https://docs.microsoft.com/en-us/ firewall setup, networking, web certification, IIS, etc.). dynamics365/business-central/dev-itpro/deployment/system- * Customer agrees to refine this configuration to optimize the system performance to support customer business dynamics. For example, by add requirements-business-central-v18 new Web server to split processor, memory and hard disk resource. * Minimum network bandwidth requirement per Remote Client (WAN) is 30 KB/s with maximum latency 100 ms. The consumption of bandwidth per PT Importa Jaya Abadi user can be very dynamic, dependent on the use of the system. The numbers provided give a conservative rule to follow when designing and reviewing the infrastructure. MS Dynamics 365 Business Central – System Infrastructure * For development environment, user can use Visual Studio Code and SQL Server Report Builder (for reporting purpose). Designed By & Property of PT SME Solution * Please checkhttps://learn.microsoft.com/en-us/dynamics365/business-central/dev-itpro/deployment/system-requirements-business-central-v22 for further details. May 12th, 2023