You are on page 1of 4

DESCRIPTION

VSP series float level switch are specially usind for monitoring and controlling the level of corrosive liquids.
All the wet parts material are using the plastic parts such as PVC, CPVC, PTFE and PVDF.
VSP float level switch is excellent for Emptying, Filling, Contact output or Alarms of Chemicals like HCL,
H2SO4, NaOH, and many more chemical liquids.

OPERATION PRINCIPLE
VSP float level switch uses a magnet and reed
+ switch to detect and control liquid presence.
The hermetically reed switch that installed inside the
Tube
guide tube will actuate from an applied of magnetic
Float field from the float.
Reed Switch
The float will be moving up and down through the
guide tube due to the liquids level movement.
Magnet When the float is at the position of reed contact
set point, the reed switch will open or close depending
on the application requirement.
The set points will be provided by two (2) pieces of
Stopper stopper.
+ The set points can be up to 8 points contacts.

SPECIFICATION
MODEL = VSP MODEL = VSTF
125 90
1A 1A = PP + 20%GF Housing, IP-65
1B 1B = PTFE Housing,IP-65
100

2A = Cable Gland, ½”NPT


115

2A 2B
2B = Cable Gland, PG 16
3B 3A = Flange or Screw Conn
3A PVC or CPVC Material
3B = Flange or Screw Conn
4A 4B PTFE Material
L1

+
L1

+ 4A = Guide Tube, 22mm


5A 5B PVC or CPVC Material
4B = Guide Tube, 16mm
L2
L2

+ 6A + 6B PTFE + 316SS Material


5A = Float PP Material
22
Ln

16 5B = Float PVDF Material


Ln

+ + 6A = Stopper, PP Material
L
L

6B = Stopper, PTFE Material

+ +
+ +
100
100

+ + Ln = “n” available up to 8 contact points


MODEL VSP VSTF
APPLICATION Waste Water, HCL, NaOH,Alum etc H2SO4 and Acids
PRESS MAX (Barg) 3
TEMP MAX (Deg C) 50 (PVC Tube) & 70 (CPVC Tube) 80
MOUNTING TOP
SG MIN (Kg/m3) 700 800
FLOAT TYPE FPP45 (Standart) or FP55 (on Request) FDF-50
FLOAT MATERIAL PP (standard) , PVC on Request PVDF
TUBE MATERIAL PVC or CPVC (Option) PTFE Cover + SS316
CONN MATERIAL PVC or CPVC (Option) PTFE
TERMINAL BOX ABS (DIN Housing-IP65) PTFE (IP65) or ABS
ELECT CONN Cable Gland, ½”NPT , IP68, Polyamid Cable Gland, PG16, IP68, Polyamid
OUTPUT CONTACT SPST, 2A, 400VAC/DC, 40VA or SPDT, 1A, 400VAC/DC, 40VA
FLOAT SPECIFICATION
ØC

B
ØA

DIMENTION (MM) SG Min P Max T Max


MODEL MATERIAL APPLICATION
ØA B ØC (Kg/m3) (Barg) (ºC)
FPP-45 PP 45 55 25 800 2 80 Water, Demin Water, Acids etc
FP-55 PVC 55 60 25 850 2 50 Water, Demin Water, Acids etc
FDF-50 PVDF 50 60 20 900 2 100 Highly Corrosive Chemicals

TERMINAL HOUSING
PP HOUSING 125 PTFE CYLINDER HOUSING 90

MODEL
90

85
MATERIAL PP + 20% GF PTFE
PROTECTION IP-65 IP-65
ELECT CONN Polyamid ½”NPT Gland Polyamid PG-16 Gland
AMBIENT TEMP 80 °C 100 °C
NO OF CONTACT 5 x SPDT & 8 x SPST 4 x SPDT & 6 x SPST

ORDERING LENGTH & WIRING


Please specify the length of L1, L2, L3, L4, L5, L6, L7 or L8
according to your requested contact points.
Please also inform whether the Contact action is NC (Normally closed)
or NO (Normally Open). Default output contact was NC.
1 x Contact (S1) 2 x Contact (S2)
L1 = ............ mm NC NO L1 = ............ mm NC NO
L = L1 + 100 mm L2 = ............ mm NC NO
L1

+
L = L1 + 100 mm
OPEN AT FLOAT
RISING (NC)

L1 L1 L2
L2

+
+ + + + + + + + +
L3

+ +
+ + + + + +

1 2 1 2 3 4
L4

+ 3 x Contact (S3) 4 x Contact (S4)


L

L1 = ............ mm NC NO L1 = ............ mm NC NO
+ L2 = ............ mm NC NO L2 = ............ mm NC NO
CLOSE AT FLOAT

L3 = ............ mm NC NO L3 = ............ mm NC NO
RISING (NO)

L = L1 + 100 mm L4 = ............ mm NC NO
+ L = L1 + 100 mm
+ L1 L2 L3 L1 L2 L3 L4

+ + + + + + + + + + + + + +
100

+ +
+ +
+ + + + + + + + + + + + + + +

1 2 3 4 5 6 1 2 3 4 5 6 7 8
RELAY PROTECTION UNIT OPTIONAL
VSP series float level switch can be used with the “WINGEL” control unit CU-1, CU-3 or CU-4 for
protection of the reed switch . The control unit will also be given the control relay output for emptying process
or filling process (CU-1) and emptying or filling process and alarm high & low output relay (CU-3) and
only given the 4 output relay (CU-4).

H H Relay
Control
H Alarm
L Alarm

LL Relay

H Relay
L Relay
OUTPUT
Relay Output
Control Pump OUTPUT
Start & Stop
+
+
+ HH
+ HH
H +
+
+
+ H
+
H
+
+
+
L
+ L
+ +
+
+
L LL
HL C + LL L HHHC LL
+ + LL L HHHC
220 Vac 220 Vac 220 Vac

ORDERING CODE
MODEL DESCRIPTION
VSP Float level switch with flange (screw) and tube in PVC, float in PP & PP housing
VSCP Float level switch with flange (screw) and tube in CPVC, float in PP or PVDF & PP housing
VSTF Float level switch with flange (screw) and tube in PTFE, float in PVDF & PTFE or PP housing

CODE 1 PROCESS CONNECTION SIZE


2 2" (50) 2-1/2" (65) 3" (80) 4" (100) Others, Please Contact

CODE 2 PROCESS CONNECTION TYPE AND RATING


FJ SR = Screw RUCIKA SB = Screw BSP SN = Screw NPT
FJ = Flange JIS 10K FA = Flange ANSI 150RF FD = Flange DIN /PN10

CODE 3 NO OF CONTACT OUTPUT


S4 S1 = 1 x SPST Contact S2 = 2 x SPST Contact S3 = 3 x SPST Contact
S4 = 4 x SPST Contact S5 = 5 x SPST Contact Others & SPDT, Please Contact

CODE 4 GUIDE TUBE LENGTH (MM)


L1000 Guide Tube Lenght Max 6000 mm (All with SS Tube Inside)
CODE 5 FLOAT TYPE
FPP45 FPP45 (PP)
FP-55 (PVC) FVD50 (PVDF)

CODE 6 OPTIONS
0 No Options
Ex Available with Ex-proof Enclosure (Please contact)

VSP-2FJ-S4-L1000-FPP45-0 .................................................................................... Example

Wingel Measurement & Control


Agent & Distributor:

PT. TAWIN CITRA INSTRUMENT


Process Instrument & Control
Ruko MIAMI Blok. A-20 CITY RESORT - CENGKARENG
TCI JAKARTA BARAT 11730
Phone : 62-21-56955637, 56955638 / Fax : 62-21-56955636
Email : sales@tawincitra.com , tawin@centrin.net.id / Webside : www.tawincitra.com

You might also like