You are on page 1of 20

OOB limits applicable to

Operating Channel
(See Figure 5)

f is the measurement frequency.


fc is the Operating Frequency.
Flow_OFB is the lower edge of the Operational Frequency Band.
Fhigh_OFB is the upper edge of the Operational Frequency Band.
OCW is the operating channel bandwidth.

fc = 869.525 MHz
OCW = 200 KHz
f ≤ flow_OFB - 400 kHz
Flow_OFB - 400 kHz ≤ f ≤ flow_OFB - 200 kHz
flow - 200 kHz ≤ f < flow_OFB
f = flow_OFB
f = fhigh_OFB
Fhigh_OFB < f ≤ fhigh_OFB + 200 kHz
Fhigh_OFB + 200 kHz ≤ f ≤ fhigh_OFB + 400 kHz
Fhigh_OFB + 400 kHz ≤ f

flow_OFB 869.400E+6
flow_OFB - 400 kHz 869.000E+6
flow_OFB - 200 kHz 869.200E+6

fhigh_OFB 869.650E+6
fhigh_OFB + 200 kHz 869.850E+6
fhigh_OFB + 400 kHz 870.050E+6

Lower out of Band Measurement


Upper out of Band Measurement
Transient Power 5.10
-0,5 x OCW - 3 kHz
0,5 x OCW + 3 kHz
Not applicable for OCW < 25 kHz OCW = 200 KHz in this project DEP IP

±max (12,5 kHz, OCW)


-0,5 x OCW - 400 kHz -500000
0,5 x OCW + 400 kHz 500000

-0,5 x OCW -1 200 kHz -1300000


0,5 x OCW + 1 200 kHz 1300000

Duty Cycle
seconds
TX ON 0.05
TX OFF 600
f = fc- 2.5 x OCW 869.025E+6 1 kHz
fc - 2,5 x OCW ≤ f ≤ fc - 0,5 x OCW 869.425E+6 1 kHz
f = fc - 0,5 x OCW 869.425E+6 1 kHz
f = fc + 0,5 x OCW 869.625E+6 1 kHz
fc + 0,5 x OCW ≤ f ≤ fc + 2,5 x OCW 869.625E+6 1 kHz
f = fc+ 2,5 x OCW 870.025E+6 1 kHz

fc + 2,5 x OCW 870.025E+6


f = fc- 2.5 x OCW 869.025E+6
f = fc + 0,5 x OCW 869.625E+6
f = fc - 0,5 x OCW 869.425E+6
OFB - 400 kHz 10 kHz -36 dBm
- 400 kHz ≤ f ≤ flow_OFB - 200 kHz 1 kHz -36 dBm
kHz ≤ f < flow_OFB 1 kHz See Figure 6
1 kHz 0 dBm
1 kHz 0 dBm
< f ≤ fhigh_OFB + 200 kHz 1 kHz See Figure 6
+ 200 kHz ≤ f ≤ fhigh_OFB + 400 kHz 1 kHz -36 dBm
+ 400 kHz ≤ f 10 kHz -36 dBm

10 kHz -36 dBm


1 kHz See Figure 6

1 kHz -36 dBm


10 kHz -36 dBm
0 KHz in this project DEP IP

869.325E+6 869.725E+6 33.333E+3


869.025E+6
870.025E+6

868.225E+6
870.825E+6

Hour
18
216000
-36 dBm
See Figure 5
0 dBm
0 dBm
See Figure 5
-36 dBm

-36 dBm
-36 dBm
0 dBm
0 dBm
so RBW = 10 KHz
fc = 434.3E+6
OCW = 400.0E+3
2.5*OCW 1.0E+6
0.5*OCW 200.0E+3
f = fc- 2.5 x OCW 433.3E+6
f = fc+ 2,5 x OCW 435.3E+6
f = fc - 0,5 x OCW 434.1E+6
fc + 0,5 x OCW 434.5E+6

f = fc- 2.5 x OCW 433.3E+6


fc - 2,5 x OCW ≤ f ≤ fc - 0,5 x OCW
f = fc - 0,5 x OCW 434.1E+6
f = fc + 0,5 x OCW 434.5E+6
fc + 0,5 x OCW ≤ f ≤ fc + 2,5 x OCW
f = fc+ 2,5 x OCW 435.3E+6
1 kHz -36 dBm
1 kHz -36 dBm
1 kHz 0 dBm
1 kHz 0 dBm

433.3E+6 ≤ f ≤ 434.1E+6 see Fig 5

433.3E+6 ≤ f ≤ 434.1E+6 see Fig 5


Lower
Upper

Flo - 200 kHz


Flo - 400 kHz

Fupper + 200kHz
Fupper + 400kHz
433.1E+6
434.8E+6

limit(dBm) RBW (kHz)


432.9E+6 -36 1
432.7E+6 -36 10

435.0E+6 -36 1
435.2E+6 -36 1