• To clean the device, wipe it gently with a soft cloth moistened This symbol indicates that the product conforms to regula-
Usage Notes
with water or mild detergent. Never use solvents such as tions set out by the EC Directive.
CLAMP ON PROBE of the jaws, so keep the surfaces clean by gently wiping with
a soft cloth.
Measurement categories
To ensure safe operation of measuring instruments, IEC 61010 • Clamp-on probe should only be connected to the
• If the device seems to be malfunctioning, contacting your establishes safety standards for various electrical environ- secondary side of a breaker, so the breaker can pre-
Instruction Manual dealer or Hioki representative. vent an accident if a short circuit occurs. Connec-
ments, categorized as CAT II to CAT IV, and called measure-
ment categories. tions should never be made to the primary side of a
August 2015 Revised edition 4
breaker, because unrestricted current flow could
Printed in Japan Pack the device so that it will not sustain damage during ship- cause a serious accident if a short circuit occurs.
9010F981-04 15-08H ping, and include a description of existing damage. We do not • Using a measuring device in an environment des- • To avoid electric shock, do not touch the portion
take any responsibility for damage incurred during shipping. ignated with a higher-numbered category than that beyond the protective barrier during use.
for which the device is rated could result in a
severe accident, and must be carefully avoided.
Safety • Using a measuring device without categories in an • Do not allow the device to get wet, and do not take
environment designated with the CAT II to CAT IV measurements with wet hands. This may cause an
This manual contains information and warnings essential for category could result in a severe accident, and electric shock.
safe operation of the device and for maintaining it in safe oper- must be carefully avoided. • To avoid electric shock when measuring live lines,
ating condition. Before using it, be sure to carefully read the fol- wear appropriate protective gear, such as insu-
lowing safety precautions. This device complies with CAT III safety requirements.
lated rubber gloves, boots and a safety helmet.
CAT II :When directly measuring the electrical outlet recepta-
cles of the primary electrical circuits in equipment con- • Avoid measuring at frequencies in excess of the
nected to an AC electrical outlet by a power cord derating range, as this will generate heat in the
• This device is designed to comply with IEC (portable tools, household appliances, etc.) jaws and is dangerous.
61010 Safety Standards, and has been thor- CAT III :When measuring the primary electrical circuits of
oughly tested for safety prior to shipment. heavy equipment (fixed installations) connected
However, mishandling during use could directly to the distribution panel, and feeders from the
result in injury or death, as well as damage distribution panel to outlets • Note that the device may be damaged if current exceeding
Warranty to the device. Using the device in a way not CAT IV : When measuring the circuit from the service drop to the selected measurement range is applied for a long time.
Warranty malfunctions occurring under conditions of normal described in this manual may negate the the service entrance, and to the power meter and pri- • Be careful to avoid dropping the device or otherwise subject-
use in conformity with the Instruction Manual and Product provided safety features. mary overcurrent protection device (distribution panel)
ing them to mechanical shock, which could damage the mat-
Precautionary Markings will be repaired free of charge. This Be certain that you understand the instruc- ing surfaces of the jaws and adversely affect measurement.
warranty is valid for a period of one (1) year from the date of tions and precautions in the manual before • Do not store or use the device where it could be exposed to
purchase. Please contact the distributor from which you pur- use. We disclaim a ny re sponsibility for a direct sunlight, high temperature or humidity, or condensa-
chased the product for further information on warranty provi- ccidents or injuries not resulting directly tion. Under such conditions, the device may be damaged
sions. from device defects. and insulation may deteriorate so that it no longer meets
• To avoid short circuits and potentially life- specifications.
Introduction threatening hazards, never attach the • Keep the jaws tip and core slits free from foreign objects,
Thank you for purchasing the HIOKI Model 9010-50, 9018-50 device to a circuit that operates at more which could interfere with clamping action.
Clamp on Probe. To obtain maximum performance from the de- than 600 V, or over bare conductors.
• Measurements are degraded by dirt on the mating surfaces
vice, please read this manual first, and keep it handy for future Instrument Installation of the jaws, so keep the surfaces clean by gently wiping with
reference. Safety Symbols Storage temperature and humidity a soft cloth.
Indicates cautions and hazards. When the symbol is : -10 to 60°C (14 to 140°F), 80%RH or less (no condensation) • To avoid breaking the cables, do not bend or pull them.
printed on the device, refer to a corresponding topic in the Operating temperature and humidity
Overview Instruction Manual. : 0 to 50°C (32 to 122°F), 80%RH or less (no condensation) • Avoid stepping on or pinching cables, which could damage
the cable insulation.
Indicates that the device may be connected to or discon-
nected from a live circuit. Avoid the following locations that could cause an accident or dam- • Keep the cables well away from heat sources, as bare con-
The 9010-50 and 9018-50 are voltage output type clamp on age to the device.
Indicates a double-insulated device. ductors could be exposed if the insulation melts.
probes, which are applicable to 500 A AC current measure- Exposed to direct
In the presence of
ments. These probes can be used to measure alternating cur- Indicates AC (Alternating Current). sunlight
corrosive or
Exposed to high tem-
rent on a live power line without the need to cut the wire. Easy explosive gases Correct measurement may be impossible in the presence of
The following symbols in this manual indicate the relative impor- perature
operation and connection make them useful for measuring alter- strong magnetic fields, such as near transformers and high-cur-
nating current and power in various fields. tance of cautions and warnings. Exposed to water, oil,
Exposed to strong
Indicates that incorrect operation presents an extreme other chemicals, or rent conductors, or in the presence of strong electromagnetic
electromagnetic
hazard that could result in serious injury or death to the solvents fields such as near radio transmitters.
fields
user. Exposed to high
Inspection and Maintenance Indicates that incorrect operation presents a significant humidity or conden-
Near electromagnetic
radiators
hazard that could result in serious injury or death to the sation
Initial Inspection user. Near induction
When you receive the device, inspect it carefully to ensure that Indicates that incorrect operation presents a possibility heating systems
Exposed to high
of injury to the user or damage to the device. (e.g., high-frequency
no damage occurred during shipping. If damage is evident, or if levels of particulate
induction heating
Indicates advisory items related to performance or cor- dust
it fails to operate according to the specifications, contact your rect operation of the device. systems and IH
dealer or Hioki representative. cooking utensils)
Subject to vibration
1 2 3 4
3. Open the jaws and clamp the conductor so that the conduc- 3. Derating
Names of Parts tor is approximately centered between the jaws. When also Specifications
measuring waveform phase with a recorder or such product,
5 6 7 8