WUXI KIPOR POWER CO., LTD.


DIESEL DIGITAL
GENERATOR
I D5000b
PREFACE

Thank you for purchasing a KIPOR generator.


This manual covers operation and maintenance of the ID5000b generator.
All information in this publication is based on the latest product information
available at the time of approval for printing.
WUXI KIPOR POWER CO., LTD. Reserves the right to make changes at any
time without notice and without incurring any obligation.
No part of this publication may be reproduced without written permission. This
manual should be considered a permanent part of the generator and remain with
it if it is resold.
Pay special attention to statements preceded by the following words:

Indicates a strong possibility of severe personal injury or


WARNING
death if instructions are not followed.

Indicates a possibility of personal injury or equipment


CAUTION damage if instructions are not followed.
If a problem should arise or if you have any questions
about the generator, consult an authorized KIPOR dealer.

KIPOR generator is designed to give safe and dependable


WARNING
service if operated according to instructions. Read and
understand the Owner's Manual before operating the
generator. Failure to do so could result in personal injury or
equipment damage.

* The illustration may vary according to the type.


Installation of wheel and handle

1.Handle installation

Handle

2.Wheel installation

Big gasket
Wheel
Wheel cover Bolt
Gasket
The choice of the electric cable CONTENTS

1. Safety Instructions 1
The choice of the electric cable depends on the allowable current of the cable
and the distance between the load and the generator. And the cable section 2. Safety Label Locations 3
should be big enough.
If the current in the cable is bigger than the allowable current, it will become over 3. Component Identification 4
hot and the cable will be burnt. If the cable is long and thin, the input voltage of
the electric appliance will be not enough, causing that the generator doesn't start. 4. Pre-operation Check 8
In the following formula, you can calculate the value of the potential "e".
5. Starting the Engine 11
1 Length
Potential (v) = Current (A) 3 6. Generator Use 13
58 Section area
The relations among of the allowable current, and length, section of the Insulating 7. Stopping the Engine 20
cable (single core, multi-core) are as follow:
(Presume that the use voltage is 220V and the potential is below 10V. 8. Maintenance 22

The application of the single-core insulating cable section mm2 9. Transporting/Storage 26


Length 10. Troubleshooting
beneath 28
50m 75m 100m 125 150 200
Current
14
11. Specifications 30
50A 8 22 22 30 38
100A 22 30 38 50 50 60 12. Electric Wiring Diagram 31
200A 60 60 60 80 100 125
300A 100 100 100 125 150 200 13. Appendix 33

The application of the multi-core insulating cable section mm2

Length
beneath 50m 75m 100m 125 150 200
Current
50A 14 14 22 22 30 38
100A 38 38 38 50 50 60
200A 38 2 38 2 38 2 50 2 50 2 50 2
300A 60 2 60 2 60 2 60 2 80 2 100 2
13. Appendix

Modified coefficient table


of ambient condition power

The conditions of generator rated output:


Altitude: 0 m Ambient temperature: 25 Relative humidity: 30%
Ambient modified coefficient: C (Relative humidity 30%)

Ambient temperature ( )
Altitude
(m) 25 30 35 40 45
0 1 0.98 0.96 0.93 0.90
500 0.93 0.91 0.89 0.87 0.84
1000 0.87 0.85 0.82 0.80 0.78
2000 0.75 0.73 0.71 0.69 0.66
3000 0.64 0.62 0.6 0.58 0.56
4000 0.54 0.52 0.5 0.48 0.46

Note: When the relative humidity is 60%, the modified coefficient is C-0.01
When the relative humidity is 80%, the modified coefficient is C-0.02
When the relative humidity is 90%, the modified coefficient is C-0.03
When the relative humidity is 100%, the modified coefficient is C-0.04
Counting example:
When the rated power of generator is PN =5KW, altitude is 1000m, ambient
temperature is 35 , relative humidity is 80%, the rated power of generator is:
P=PN (C-0.02) = 5 (0.82-0.02) = 4KW
Double Voltage
1. SAFETY INSTRUCTIONS

KIPOR generator is designed to give safe and


WARNING
dependable service if operated according to
instructions.
Read and understand the Owner's Manual before
operation. Failure to do so could result in personal
injury or equipment damage.

Exhaust gas contains poisonous carbon


WARNING
monoxide.
Never run the generator in an enclosed area.
Be sure to provide adequate ventilation.
In order to prevent electric shock, make sure ground
the generator with a lead.

The muffler becomes very hot during operation


WARNING
and remains hot for a while after stopping the engine.
Be careful not to touch the muffler while it is hot.
Let the engine cool before storing the generator
indoors.
The engine exhaust system will be heated during
operation and remain hot immediately after stopping
the engine.
To prevent scalding, pay attention to the warning
marks attached to the generator.
Charge the battery at ventilated area. Make sure no
smoke while charging.

- -
To ensure safe operation
Gasoline is extremely flammable and explosive 12. ELECTRIC SCHEMATIC DIAGRAM
WARNING under certain conditions. Refuel in a well ventilated
area with the engine stopped. Single Voltage
Keep away from cigarette, smoke and sparks when
refueling the generator. Always refuel in a well-
ventilated location.
Wipe up spilled gasoline at once.
The connection between generator and electric
WARNING system must be performed by a qualified electrician
and must comply with all applicable laws and electric
system regulations.
Improper connections can allow electric current from
the generator to back feed into the utility lines. Such
back feed may electrocute utility company workers or
others who contact the lines during a power outage,
and when utility power is restored, the generator may
explode, burn, or cause fires in the building’s electrical
system.
Always make a pre-operation inspection before you
WARNING
start the engine. You may prevent an accident or
equipment damage.
Place the generator at least 1 m(3ft) away from
buildings or other equipment during operation.
Operate the generator on a level surface.
If the generator is tiled, fuel spillage may result.
Know how to stop the generator quickly and
understand operation of all the controls. Never permit
anybody to operate the generator without proper
instructions.
Keep children and pets away from the generator
when it is in operation.
Keep away from rotating parts while the generator is
running.
The generator is a potential source of electrical
shocks when misused; Do not operate with wet hands.
Do not operate the generator in rain or snow and do
not let it get wet.
11. SPECIFICATIONS 2. SAFETY LABEL LOCATIONS
These labels warn you of potential hazards that can cause serious injury.
Specifications Read the labels, safety notes and precautions described in this manual carefully.
Model ID5000b
Rated frequency (Hz) 50 60
Rated voltage (V) 230 120/240
Warning sticker Outdoor use sticker
Rated current (A) 21.7 41.7/20.8
Rated rotation speed (r/min) 3600
4.5 Brand sticker
Rated output (kVA)
Max. output (kVA) 5.0
Fuel tank capacity (L) 20 Model sticker
Continuous running time (rated output) (hrs) 8.8 Nameplate stickerl
Noise level (dB/7m) (zero load-full load) 73 Filling port sticker
Overall dimension (L W H)[ (mm)in] 830x538x745 (32.7x21.2x29)
Net weight kg(lbs) 160 (352)

DC Output
DC Output 12V-8.3A
Current protector With
Phase number Single phase

Brand sticker
Engine
Model KDIP86FGETi Model sticker
Type Single cylinder, 4 stroke, air-cooled, diesel engine
Displacement 0.418ml
Safety warning sticker
Rated frequency[kW/(r/min)] 6.3/3600 High temperature
Rated rotation speed (rpm) 3600 sticker
Starting type Electric starter
Fuel type 0#(summer), -10#(winter)
Fuel consumption (g/kW.h) 285
Lube oil type SAE 10W30 (Above CC grade)
Lube oil capacity (L) 1.6
The engine fails to run with load:
3. COMPONENT IDENTIFICATION
Is the output indicator lamp on No Take the generator to an authorized KIPOR dealer
Fuel Filter
Stepping Motor
Yes
Low Oil Pressure Alarm Handle
No Turn on the breaker.
Is the AC breaker switched on?
Control Panel

Yes

Yes
Is the overload indicator lamp on? Lower down the load or replace the generator for a larger one
Oil Filter
Oil Dip-stick Yes
Oil Draining Bolt Motor Air Conduct Cover
Yes
Is the electric appliance in good condition? Replace or charge the electric appliance

Yes

Take the generator to an authorized KIPOR dealer.

Battery Air Filter

Oil Gauge Indicator Fuel Tank Cap

Vent
Control panel
10. TROUBLESHOOTING
A-type Control Panel for ID5000b

9
8
When the engine will not start: 6
10
No 5 Output Indicator Lamp (Green)
Is there fuel in the tank? Refill the fuel tank.
11 Overload Alarm Lamp (Red)

Yes 4
No 12 Overspeed Alarm Lamp (Red)
Is there enough oil in the engine? Add the recommended oil. 7
3 Low Oil Level Alarm Lamp (Red)
2
Yes 1
No
Is the battery voltage 12 to 15V? Replace or charge the battery 1. Panel 7. Earth terminal
2. A-type receptacle (L5-30) 8. Display
Yes 3. A-type receptacle (5-20R) 9. Breaker (2P)
4. A-type receptacle (L14-20) 10. DC receptacle
Take the generator to an authorized KIPOR dealer.
5. Switch of generator 11. Smart switch
6. Indicator lamp 12. Voltage option switch

E-type Control Panel for ID5000b


9
8
6
3
5
4

7
1
2
1. Panel Output Indicator Lamp (Green)

2. E-type receptacle Overload Alarm Lamp (Red)


3. DC receptacle
4. Smart switch
Overspeed Alarm Lamp (Red)
5. Switch of generator
Low Oil Level Alarm Lamp (Red)
6. Indicator lamp
7. Earth terminal
8. Display
9. Breaker(2P)
SMART throttle
ON: Engine speed is kept at idle automatically when the electrical appliance is
disconnected and it returns to the proper speed when electrical appliance is
connected. This device is recommended to minimize the fuel consumption while
in operation.
OFF: Smart throttle system does not operate. Engine speed is kept at rated
speed.

Oil dip-stick

Left door
Idle speed Rated speed
Oil draining bolt

Smart throttle system does not operate effectively if


NOTE
the electrical appliance requires the momentary electric
power.
When high electrical loads are connected Upper limitation level
simultaneously, turn the smart throttle switch to the
OFF position to reduce voltage changes.
In DC operation, turn the smart throttle switch to the
OFF position.

LCD directions: Lower limitation level


Oil dip-stick
For example LCD-230V:
Left door
1----Output voltage of generator(V) Oil filling port
2----Load current(A)
3----Frequency
4----Accumulated running time
5----Voltage of battery
Please press the keys on the right in turn.
1 Operation Instruction for Remote Control
9. TRANSPORTING/STORAGE

To prevent fuel spillage when transporting or during temporary storage, the


generator should be secured upright in its normal operating position, with the
engine switch OFF. Turn the cap lever fully counterclockwise to the "OFF"
position.
When transporting the generator;
WARNING
Do not overfill the tank (there should be no fuel in the
filler neck).
Do not operate the generator while it is on a vehicle.
Take the generator off the vehicle and use it in a well
ventilated place.
Avoid a place exposed to direct sunlight when putting
the generator on a vehicle. If the generator is left in an
enclosed vehicle for many hours, high temperature inside
the vehicle could cause fuel to vaporize resulting in a Operation instruction

possible explosion.
Do not drive on a rough road for an extended period
Wireless remote control is a new function for generator set, applying the remote
with the generator on board, If you must transport the
control module. You can start or stop the generator with a remote control
generator on a rough road, drain the fuel from the
within the range of 50 meters in the open area (no wall), or 20 meters if walled off.
generator beforehand.
Abnormal instruction
Before storing the unit for an extended period:
1. If the remote control is lost, please use a new one and delete the original
1. Run the generator without load for 5 minutes.
matcher of remote and module.
2. Drain out the dirty fuel when the generator is still warm and refill in some fresh
Concrete operations are as follows:
fuel.
Open the generator set cover, press the black button on the remote module for
3. Drain out the diesel in the fuel tank completely into a container.
5 to 10 seconds and loose it until the LBD is light to go out. Delete the remote
4. Wipe off the dust on the generator and store it in a dry place.
control. Press the black button, then press the remote control button within 5
seconds to make the indication lamp light for 1 second.
Gasoline is extremely flammable and explosive under
WARNING 2. If one remote control can control several generator sets, please carry out the
certain conditions.
first concrete operation. Never use two remote controls at the same time.
Do not smoke or allow flames or sparks in the area.
3. When pressing the remote control button the signal light is not on, please
change battery.
3. FUEL CLEANER SERVICE
4. PRE-OPERATION CHECK The dirty fuel cleaner will stop the fuel entering into the fuel pump, please check
the fuel cleaner periodically so that to avoid inadequate fuel level.
Be sure to check the generator on a level surface with a. Open the left maintenance cover and clip the inlet/outlet fuel pipe. Loosen the
CAUTION
the engine stopped. clip hoop and remove the fuel cleaner.
1. Check the engine oil level. b. Replace the fuel cleaner.
Using non-detergent oil or 2-stroke engine oil could c. Reassemble the cleaner element, then tighten the clip hoop and close the left
CAUTION
shorten the engine's service life. maintenance cover.

Use high-detergent, premium quality 4-stroke engine oil, certified to meet or 4. NOZZLE FUEL PUMP SERVICE
exceed the standard of SAE10W-30 (above CC or CD grade). Don't screw off the nozzle fuel pump by yourself. Replacing or cleaning of the
nozzle fuel pump needs professional tools and technology; please consult with
Select the appropriate viscosity for the average temperature in your area. the KIPOR dealers.

SAE Viscosity Grades

-20- -10 0 10 20 30 40

0 20 40 60 80 100

Loosen the cover screw and remove the left side maintenance cover.
Remove the oil filler cap, and wipe the dipstick with a clean rag. Check the oil
level by inserting the dipstick in the filler hole.
If the oil level below the end of the dipstick, refill the recommended oil up to the
top of the oil filler neck.

Running the engine with insufficient oil can cause


NOTE
serious engine damage.
Please dispose of used motor oil in a manner that is Note The Oil Alert System will automatically stop the engine before the oil level
NOTE
compatible with the environment. We suggest you take it falls below the safe limit. However, to avoid the inconvenience of an unexpected
in a sealed container to your local service station for shutdown, it is still advisable to visually inspect the oil level regularly.
reclamation. Do not throw it in the trash or pour it on the
Upper limitation level
ground.
2. AIR CLEANER SERVICE
A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor
malfunction, service the air cleaner regularly. Service more frequently when
operating the generator in extremely dusty areas.
Do not use gasoline or low flash point solvents for Lower limitation level
CAUTION Oil dip-stick
cleaning. They are explosive under certain conditions.
Left door
Oil filling port
a. Loosen the cover screw and remove the left side maintenance cover.
2. Check the fuel level
b. Screw off the nut on the top of the air cleaner body, and remove the air cleaner
Use the automotive light diesel.
cover.
If the fuel level is low, refuel the fuel tank until the level as specified.
c. Remove the cleaner element.
Never use an oil/diesel mixture or dirty diesel.
d. Wash the element, but not with detergent. Avoid dirt, dust or water getting in the fuel tank.
e. Replace the element in case of reduced output or bad exhaust. After refueling, tighten the fuel filler cap securely.
f. Don't start the generator set without air cleaner element.
g. Reassemble the element and air cleaner cover. Close the left maintenance The fuel is extremely flammable and is explosive
cover. WARNING under certain conditions.
Refuel in a well-ventilated area with the engine
stopped.
Do not smoke or allow sparks in the area where the
engine is refueled or where gasoline is stored.
Do not overfill the fuel tank (there should be no fuel
above the upper limit mark)- After refueling, make sure
Seal ring of air filter shell the tank cap is closed properly and securely.
Butterfly nut Be careful not to spill fuel when refueling. Spilled fuel
or fuel vapor may ignite. lf any fuel is spilled, make sure
Air filter bottom sealing
the area is dry before starting the engine.
Air filter element Avoid repeated or prolonged contact with skin or
Air filter cover
breathing of vapor. KEEP OUT OF REACH OF
CHILDREN.
3. Check the air cleaner. 1. CHANGING Oil
Check the air cleaner element to be sure it is clean and in good condition. Drain the oil while the engine is still warm to assure rapid and complete draining.
Loosen the cover screw and remove the right side maintenance cover. Press the
latch tab on the top of the air cleaner body, remove the air cleaner cover, and Make sure to turn off the engine switch before
WARNING
check the element. Clean or replace the element if necessary. draining.

1. Loosen the cover screw and remove the left side maintenance cover.
2. Drain dirty oil into a container thoroughly.
3. Refill with the recommended oil, and check the oil level.
Seal ring of air cleaner shell 4. Reinstall the left side maintenance cover and tighten the cover screw securely.
Butterfly nut
Air filter bottom Engine oil capacity: KD1P86FGETi-1.65L

Air filter element


Air filter cover

Never run the engine without the air cleaner. Rapid


CAUTION
engine wear will result for130m contaminants, such as
dust and dirt, being drawn through the carburetor, into the Oil dip-stick

engine. Left door


Oil draining bolt

Fuel tank cover


Fuel scale indicator Upper limited
Upper limited level Fuel tank cover
Lower limited level
level
Upper limitation level

Fuel scale indicator

4. Check the fuel cleaner


Check the fuel cleaner to be sure that it is clean and in good condition. Lower limitation level
Oil dip-stick
Loosen the cover screw and remove the left side maintenance cover. Check the Left door
fuel cleaner element, clean or replace it if necessary. Oil filling port
8. MAINTENANCE 5. STARTING THE ENGINE

The purpose of the maintenance and adjustment schedule is to keep the Before starting the engine, disconnect the load from the DC terminals.
generator in the best operating condition.
1. Turn the breaker to the OFF position.
Shut off the engine before performing any maintenance.
WARNING
If the engine must be run, make sure the area is well
ventilated. ON

Use genuine KIPOR parts or their equivalent. The use OFF


CAUTION
of replacement parts which are not of equivalent quality
may damage the generator.
Maintenance schedule
Breaker
ITEM
First Every 3 Every 6 Every
REGULAR SERCIVE (1) Each month months months year
Perform at every indicated use or or or or
month or operating hour interval, 2. Turn the switch to the START position to start the generator. Loosen the engine
20 hrs 50hrs 100hrs 300 hrs
whichever occurs first. switch after starting and the switch will automatically reset. If the generator fails to
Check start after 5 seconds, please wait for another 10 seconds before restart.
Engine oil (the 2 ndti me (the 2 ndt ime
Change (the 1st time) or later) or later)
Fuel cleaner Clean or replace (replace)
Check
Air cleaner
Clean (2)

Fuel pump nozzle Clean-adjust (3) OFF START


Valve clearance Check-adjust (3)

Fuel tank and cleaner Clean or replace OFF START


Fuel line Check Every 2 years (Replace if necessary) (3)

NOTE: (1) Log hours of operation to determine proper maintenance.


(2) Service more frequently when used in dusty areas.
(3) There items should be serviced by an authorized KIPOR dealer,
unless the owner has the proper tools and is mechanically proficient. See
the KAMA shop Manual.
3. Turn the breaker to the ON position. 3. Turn the engine switch to the "OFF" position.

ON

OFF START
OFF OFF START

Breaker

The battery voltage will be lowered down if the starting


CAUTION
motor has worked for a long time.

5. Instruction
The diesel engine can reach the rated power described on the nameplate only at
the standard working condition. Modify the output and fuel consumption ratio
according to Rule GB/T6072.1, in case that the testing condition is not the same
with the standard working condition.
7. STOPPING THE ENGINE 6. GENERATOR USE

To stop the engine in an emergency, turn the engine switch to the OFF position. To prevent electrical shock, the generator should be
IN NORMAL USE:
WARNING
grounded. Connect a length of heavy wire between the
1. Switch off the connected equipment and pull the inserted plug generators ground terminal and the external ground
2. Turn the breaker to the OFF position. terminal.
Connections for standby power to a building's
electrical system must be made by a qualified
electrician and must comply with all applicable laws
and electrical codes. Improper connections can allow
electrical current from the generator to backfeed into
the utility lines. Such backfeed may electrocute utility
company workers or others who contact the lines
during a power outage, and when utility power is
restored, the generator may explode, burn, or cause
fires in the building's electrical system.

Generator overload is prohibited.


WARNING
Do not exceed the current limit specified for any one
receptacle.
Do not connect the generator to a household circuit.
This could cause the damage to the generator or to
Breaker electrical appliances in the house.
Do not modify or use the generator for other
purposes than it is intended for. Also observe the
following when using the generator.
¡¤
Do not connect generators in parallel.
Do not connect an extension to the exhaust pipe.
When an extension cable is required, be sure to use
a tough rubber sheathed flexible cable.
Limit length of extension cables; 60m for cables if
1.5mm2 and 100m for cables of 2.5mm2.
Keep the generator away from other electric cables
or wires such as commercial power supply lines.
The DC receptacle can be used while the AC power is in 6.4 The electric device, especially the motor driving device will generate much
NOTE starting current during starting. The following table is given for your reference.
use. If you use both at the same time, be sure not to
exceed the total power for AC and DC.
Most appliance motors require more than their rated Voltage Example
Type Electric device
wattage for start-up Starting Rated Device Starting Rated
Incandescent lamp
6.1 AC applications
Incandescent
1. Start the engine and make sure the output indicator light (green) comes on. lamp
100VA 100VA
2. Confirm that the appliance to be used is switched off, and plug in the appliance. Heating device X1 X1 Incandescent
lamp (W) (W)
100W
Substantial overloading that continuously lights the Television
CAUTION
over-load indicator light (red) may damage the generator. Fluorescent
Marginal overloading that temporarily lights the overload lamp 80VA 60VA
X2 X1.5
Spot lamp 40W (W) (W)
indicator light (red) may shorten the service life of the
Sodium lamp Fluorescent lamp Fluorescent lamp
generator.
Be sure that all appliances are in good working order Refrigerator
before connecting them to the generator. If an appliance
begins to operate abnormally, becomes sluggish, or stops
Motor Electric
suddenly, turn off the generator engine switch immediately. driving fan 450-750VA 300VA
X3~5 X2
Then disconnect the appliance, and examine it for signs of device Refrigerator (W) (W)

malfunction. 150W
Motor
Electric drill
6.2 Output and Overload indicators
Switch power
The output indicator light (green) will remain ON during normal operating
supply
conditions. Rectifying
X2 X2 400VA 400VA
Output indicator light (green) power supply Computer CPU UPS power (W) (W)
power supply supply 200W
Overload alarm light (red)
Low oil level alarm light (red)
Overspeed alarm light (red)

If the generator is overloaded (in excess of 6.8kVA), or if there is a short in the


connected appliance, the output indicator light (green) will go OFF, the overload
indicator light (red) will go ON and current to the connected appliance will be shut
off.
The DC receptacle may be used while the AC power is in use. Output indicator light (green)
An overload DC circuit will trip the DC circuit protector. If this happens, wait a Overload alarm light (red)
few minute before pushing in the circuit protector to resume operation. Low oil level alarm light (red)
Overspeed alarm light (red)
Stop the engine if the overload indicator light (red) comes ON and investigate the
overload source.
Before connecting an appliance to the generator, check that it is in good
condition, and that its electrical rating does not exceed that of the generator. Then
connect the power cord of the appliance, and start the engine.

CAUTION When an electric motor is started, both the overload


indicator light (red) and the output indicator light (green)
may go on simultaneously. This is normal if the
ON OFF
overload indicator light (red) goes off after about four (4)
seconds. If the overload indicator light (red) stays on,
consult your KIPOR generator dealer.
Oil alert system
The oil alert system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the crankcase
falls below a safe limit, the oil alert system will automatically shut down the
engine (the engine switch will remain in the ON position).

If you try to restart the engine after it being shut off by the oil alert system, the low
oil level alarm light (red) will go on and the engine can't run. In this case, please
fill in fresh oil.
Output indicator light (green)
Overload alarm light (red)
Low oil level alarm light (red)
Overspeed alarm light (red)
Overspeed alert system To prevent the possibility of creating a spark near the
WARNING
The generator will stop running immediately after the engine speed exceeds the battery, connect charging cable first to the generator,
rated speed for 0.5-3 seconds. then to the battery. Disconnect cable first at the battery.
Output indicator light (green) Before connecting charging cables to a battery that is

Overload alarm light (red) installed in a vehicle, disconnect the vehicles grounded
battery cable. Reconnect the vehicle's grounded
Low oil level alarm light (red)
battery cable after the charging cables are removed.
Overspeed alarm light (red)
This procedure will prevent the possibility of a short
6.3 DC usage
circuit and sparks if you make accidental contact
The output voltage for DC receptacle in zero load is 14V and the current is 8.3A.
between a battery terminal and the vehicle's frame of
The DC receptacle is used only for charging of 12V automatic battery. body.

In DC operation, turn the Smart throttle switch to the OFF Do not attempt to start an automobile engine with the
NOTE CAUTION
position. generator still connected to the battery. The generator
may be damaged.
Connect the positive battery terminal to the positive
charging cord. Do not reverse the charging cables, or
serious damage to the generator and/or battery may
occur.

The battery gives off explosive gases; keep sparks,


WARNING flames and cigarettes away. Provide adequate
ventilation when charging.
The battery contains sulfuric acid (electrolyte).
Contact with skin or eyes may cause severe burns.
Wear protective clothing and a face shield.
-If electrolyte gets on your skin, flush with water.
-If electrolyte gets in your exes, flush with water for at
least 15 minutes and call a physician.
Electrolyte is poisonous.
-If swallowed, drink large quantities of water of milk and
follow with milk of magnesia or vegetable oil and call a
physician.
Keep out of reach of children.