100
“150
SHOCK-RESISTANT PRESSURE GAUGE
(F,Y,T)
Operation Instruction
Cc
Shaanxi No.00000314 Metering No. (014)
Qinchuan Machine Tool Group Baoji Instrument Co.,Ltd.
1S09001 Quality Management System
Pi
886 15010012 Measurement Management System
|
|
|
|YK~100 (P,Y,1)SHOCK-RESISTANT PRESSURE GAUGE
Brief Introduction
YK-199 (F,Y,T)shock-resistant pressure gauge is widely used
for measuring pulsating pressure in the fields of petroleum ,coal,
geology .It also can measure severe pulsating pressure.
Having excellent performances of shock-resistant . It can not
only measure severe pulsating pressure but also bear transient
pressure and shock in mounting.
Having clog-proof ability. Measured media can’t enter gauge
which allows media can be high viscous, easy condensed matter,
such as mud.
Having dependable sealing and corrosion ~ proof ability. Gauge
can be used in adverse environment (such as in the open air,
high humidity).
Carried standard: JB/T 6804
Main Technical Parameters
1.Measurement range (MPa) and accuracy
Measurement range Accuracy
0~16; 0~25 2.5
0~40; 0~ 60; 0~ 80; 0~ 100; 0~ 120, 0~ 160 1.6
0~160MPa is in Yk100 series
2. Ambient temp. :~25—S5°C
3.Ambient shock can’t pass Grade V. H.4, GB4439.
4:Weight : about 4Kg
5.Outline drawing as following.(unit in mm)O14 5
63
|
‘M20X1.5, M42X2, Ri}, R2, NPT2, |
|
YK-100 structure & outine size
$150 58
Riz, R2, NPT2,
YK-150 structure & outine size
mh |
|
|
|‘YK-15OF flange type
YK-150U special connecting type
oe6. About type
YK
—— Vocanoj-oammamn ype; F-fange ype; Y-specialoomenting types Tsong damping pe
case diameter
shock-resistant pressure gauge
Principle & Structure
Gauge consists of sealing gasket ,a set of diaphragm, plate
spring driving, indicating and house. The pulsating
pressure from measured media which actuates to gasket,
becomes steady by diaphragm, since the flow rate is
limited when fluid flowing through capillary pipe, the
pulsating pressure is attenuated .And the plate spring is
forced to distort which causes the dial to turn , thus the
measured pressure is indicated.
Operation Direction
1.Gauge should be mounted in vertical direction .And
mustn’t attach any dampers in mounting location ,and
keep the gauge as near as possible to the mounted site.
2.The gauge should be kept between 1/3 ~ 2/3 of upper
limit to guarantee life and accuracy .
3.If ambient temp. deflects from 20~ 30, please
consider temp. Error.
-4-4.Don’t fill the gauge with any other oil .
5.Please loosen the oiling screw to release inner
pressure while operating and tighten up screw again to
prevent leaking before dismantling .
6.The gauge should be inspected regularly, and
inspectand repair the gauge before using again.
Order Information
Please note clearly the model, type, range, accuracy,
and installing thread , especially for the gas media .
-5-——— —
Qinchuan Machine Tool Group Baoji Instrument Co.,Ltd.
Tel: 09173622315 3617369
Fax: 0917-3622315 3623378
‘Add: No.14, Qingjiang East2 Road, Baoji City, Shaanxi
E-mail: qebjyb@qcbjyb.com
Http: www.qebjyb.com