List of error messages in M3 CU, possible reasons and
process to extract Result during counting day
Sl Message on CU Possible reason Remedy to extract result
1. “INCORRECT NUMBER Close operation was not i. Press Ballot key once and OF BU” performed on Polling day observe “EVM IS READY” “PRESS BALLOT KEY” message. message is displayed ii. Press Close key to perform Close after displaying battery operation. status iii. Press Result key to display individual candidate results 2. FIXED LOAD ENABLE Load regulator enable is high If CU flashes “FIXED LOAD ENABLE HIGH even after turning off the HIGH” message on press of TOTAL load while measuring key/CLOSE key/RESULT key then dynamic impedance Press and hold BALLOT key (don’t restart the CU) until CU stops displaying the error message(hold time: max 5 seconds).
If CU flashes “FIXED LOAD ENABLE
HIGH” message at power on, then Turn off the CU and turn on after 5 minutes and check. Replace the CU if error persists. 3. INVALID message Result or Print key might be Option1: displayed on power on in pressed condition Adjust CU top cover by loosening the screw near the close key and restart, if problem persists press and release RESULT and PRINT key for few times. Restart the CU Option2: Count slips from VVPAT 4. INVALID message “INVALID” display indicates Perform CLOSE operation by displayed on press of that a button on the pressing CLOSE key. After RESULT key Control Unit has been completion of the display messages, pressed out of sequence perform RESULT operation 5. DIGIT XX NOT OK Measured segment current Option1: value is out of defined limits Connect PADU and perform RESULT for that particular DIGIT operation Option2: Count slips from VVPAT
EVM R&D Confidential Page 1
Electronics Corporation of India Limited
6. POWER ON LED Measured Power on LED Option1:
NOT OK current value is out of Connect PADU and perform RESULT defined limits operation Option2: Count slips from VVPAT 7. BUZZER NOT OK Measured Buzzer current Option1: value is out of defined limits Connect PADU and perform RESULT operation Option2: Count slips from VVPAT 8. BUSY LED Measured busy LED current Option1: NOT OK value is out of defined limits Connect PADU and perform RESULT operation Option2: Count slips from VVPAT 9. CAND SET KEY NOT OK/ Candidate set key is in Option1: BALLOT KEY NOT OK/ pressed condition Connect PADU and perform RESULT TOTAL KEY NOT OK/ operation CLEAR KEY NOT OK/ Option2: RESULT KEY NOT OK/ Count slips from VVPAT PRINT KEY NOT OK/ CLOSE KEY NOT OK 10. CHANGE BATTERY CU Battery drained Replace battery with new one and perform Result operation 11. Both POWER ON and CU Battery drained and Option1: BUSY LEDs are unable to display message Replace battery with new one and continuously blinking perform Result operation during power on Option2: Count slips from VVPAT 12. INOPERATIVE/ Key pair erased Option1: FACTORY MODE Connect FVU along with printer to CU and turn on the CU. Result will be printed. Option2: Count slips from VVPAT 13. CLOCK ERROR Indicates the malfunction Result will be displayed on press of of Real Time Clock. Result key 14. CU ERROR Count slips from VVPAT Integrity of the Control Unit is failed and cannot be used for election purpose. 15. ERROR Memory contents might be Count slips from VVPAT disturbed or not properly initialized during the factory Note: Selection of option to extract result is based on final decision from the concerned RO