You are on page 1of 21

BTS3900 V100R008C00SPC260 (NodeB)

Upgrade Guide (LMT-Based)

Issue 01

Date 2014-06-16

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Website: http://www.huawei.com

Email: support@huawei.com

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei i
Technologies Co., Ltd
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide Contents

About This Document

Author
Prepared By Alexandru Gaina Date 2014-06-16
Reviewed By
Tested By
Approved By

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei ii
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

The version V100R008C00SPC260 for multimode base stations corresponds to the version
V200R015C00SPC260 for NodeBs.
This upgrade guide describes how to upgrade a NodeB on the local maintenance terminal
(LMT).

1.1 Version Requirements


1.1.1 Requirements for NodeB Software Version

Table 1-1 Flash upgrade policy


Flash Version Upgrade Policy

V200R013 and later It can be directly upgraded to BTS3900


V100R008C00SPC260.
Versions earlier than V200R013 It must be upgraded to V200R013 or V200R014
and then to BTS3900 V100R008C00SPC260.

1.1.2 Version Requirements for Other NEs


Check "Related Product Version" and "Software Versions" in the BTS3900
V100R008C00SPC260 (NodeB) Release Notes to determine whether the RNC, CME, LMT,
and M2000 should also be upgraded.

 To ensure that the NodeB can be upgraded properly using the LMT, the version of the
web browser running on the PC on which the LMT software is installed (LMT PC for
short) must meet the following requirements:
− Microsoft Internet Explorer 8 or 9
− FireFox 3.0 or later

 Check whether the local maintenance IP address of the source NodeB has been changed
before an upgrade. If it was changed, obtain the new IP address.
The default maintenance IP addresses are 192.168.0.49 and 17.21.2.15 and the mask is
255.255.255.0.

Setup your network IP:

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 1
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

Or :

Log on WEB LMT using name and Password of the default values admin and hwbs@com
(or NodeB ).

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 2
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

During the upgrade, wait for the command response and check whether the command runs
successfully before you run the next command. If the command fails, follow the
instructions provided in this guide.
 Do not perform any configuration operations, such as running ADD, MOD, RMV, or
SET commands during an upgrade. Perform operations on the NodeB only when the
NodeB software status is displayed as Idle. Therefore, log in to the LMT and run the
DSP SOFTSTATUS command to query the NodeB software status before performing
any operation.
 When upgrading the NodeB software, do not:
− Power off the NodeB.
− Manually restarting the main control board.
− Connect or disconnect optical fibers.
− Reset the NodeB or a board in the NodeB by running commands or pressing the
board reset button.
 If there is a standby main control board, check whether it is available before the upgrade.
 If the upgrade fails or the network performance seriously deteriorates in the dialing test
after the upgrade, a version rollback is recommended.
The rollback depends on the real situations of the network and the requirements of the
customer. For details about how to perform the rollback, see chapter Error: Reference
source not found"Error: Reference source not found."
 The screenshots in this document assume that the NodeB version is BTS3900
V100R008C00SPC260.

1.1.3 Duration for Downloading the NodeB Software


Table 1-1 lists the durations for downloading the NodeB software on the LMT with different
OMCH bandwidth configurations.

Table 1-1 download durations at different OMCH bandwidths on the LMT


OMCH Bandwidth Duration for Downloading NodeB Software (for Remark
Reference Only)
10 Mbit/s 15' Local
128 kbit/s, VBR 69'43" Remote
512 kbit/s, VBR 22' Remote

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 3
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

1.1.4 Preparing the Upgrade Software Package


Base Station Software Packages
Table 1-1Table 1-1 describes the base station software packages.

Table 1-1 Base station software packages


Softwar Packag Software Version Package Name at
e e Type http://support.huawei.com
Package

SRAN SRAN BTS3900 BTS3900 V100R008C00SPC260


package package V100R008C00SPC26 _ALL(Software).zip
0
Single- GBTS BTS3900 BTS3900
mode package V100R008C00SPC26 V100R008C00SPC260_GBTS(Software).zi
package 0 p
NodeB BTS3900 BTS3900
package V100R008C00SPC26 V100R008C00SPC260_NodeB(Software).z
0 ip
eNodeB BTS3900 BTS3900
package V100R008C00SPC26 V100R008C00SPC260_eNodeB(Software).
0 zip

Software Package Description


 The software version of SRAN8.0 base stations is V100R008. Software packages for
GBTSs, NodeBs, eNodeBs, and multi-mode base stations (MBTSs) are packed into the
software package for SRAN.
 The size of the software package for SRAN is large. To reduce time required for
downloading software packages, you can download only the software package for the
corresponding base station. The software version of single-RAT base stations is also
V100R008.

Obtaining Software Packages

Step 1 Download BTS3900 V100R008C00SPC260_NodeB(Software).zip and BTS3900


V100R008C00SPC260 Hash List-EN.zip to a local PC where the M2000 client has been installed.
Step 2 Save and decompress BTS3900 V100R008C00SPC260_NodeB(Software).zip to the D:\ BTS3900
V100R008C00SPC260 directory.
Figure 1-1 displays the directory structure of the files after decompression.

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 5
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

Figure 1-1 Directory structure

1.2 Preparing Resources for Verification and Spare Parts


The resources for verification required after the upgrade are as follows:
 UEs for dialing tests
 SIM cards
 Test vehicles
Prepare spare parts according to the actual requirements.

1.3 Installing the LMT


If the UMPT works as the main control board, LMT installation is not required.
If the WMPT works as the main control board, to install the LMT corresponding to the
current NodeB version, perform the following steps:
Step 1 Log in to the operating system as an administrator.
Step 2 Double-click setup.exe in the LMT installation directory to start installing the LMT.
Step 3 Install the LMT by using the default settings.
The default installation path is D:\HW LMT.

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 6
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

1.4 Verifying the NodeB Software Version


Verify the NodeB software version and record the information for version backup. To verify
the NodeB software version, perform the following steps:
Step 1 Log in to the LMT, and click Device Maintenance.
Step 2 On the left pane, choose Device Maintenance > BTS Maintenance.
Step 3 On the left navigation tree, double-click Software Management.
The Software Management tab page is displayed.
Step 4 Click Query and record the software version displayed on the Message tab page, as shown in Figure 1-1.

Figure 1-1 Querying NodeB software version

Step 5 Click the MML tab.

Step 6

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 7
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

1.5 Confirming the FTP Status


1.5.1 Checking the Connection Between the LMT PC and the
NodeB
To check the connection between the source NodeB and the LMT PC, perform the following
steps:
Step 1 Use a maintenance transfer cable to connect the USB port on the main control board to the LMT PC.
Step 2 Configure the IP address of the LMT PC on the same network segment as the local maintenance IP
address.
Step 3 Under the Windows operating system, Choose Start > Run.
The Run dialog box is displayed. Enter cmd and click OK. At the command prompt, enter
Ping following the local maintenance IP address.
If the IP address of the local maintenance IP address can be pinged through, the NodeB is
correctly connected to the LMT PC.
----End

1.5.2 Configuring the FTP Server


The software packages must be downloaded using the FTP server (SFTPServer.exe).
To ensure that the NodeB software, data configuration file, and license file can be normally
downloaded, configure the FTP server as follows:
Step 1 Log in to the LMT. In the upper right corner of the main window, click FTP Tool to download the FTP
tool to the local PC.
Step 2 After the download is complete, double-click SFTPServer.exe to decompress the file.
Step 3 In the directory for saving the decompressed files, double-click SFTPServer.exe to start the FTP
software.

If the icon is displayed on the right of the taskbar after the software starts, the FTP server
has started successfully.

NOTE

If the icon is displayed on the right of the taskbar, the FTP server has not started. If this occurs, check
whether other FTP software is running on the PC. If other FTP software is running, exit it. Then, right-
click this icon and choose Start FTP server from the shortcut menu to start the FTP server.

Step 4 Right-click and choose FTP server configure from the shortcut menu. The FTP server configuration
dialog box is displayed, as shown in Figure 1-1.
 Set the User name and Password to the default values admin and hwbs@com
respectively.
 Set Port number to the default value 21.

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 8
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

The port number is set according to the mapping between the FTP server IP addresses
and ports. For details, see Error: Reference source not found and Step 5.
 Specify the file path in which the software package is stored, for example, D:\ftp.
NOTE
The FTP server working directory and the file path in which the software package is stored must be the
same. Otherwise, you cannot download the NodeB software package.

Step 5 If the FTP server IP address is 192.168.0.50 or the IP address of the PC where the LMT for the upgrade is
installed, set Port number to the destination port number in the command output, as shown in Figure 1-1.

Figure 1-1 Configuring the FTP server

Step 6 Click OK. In the displayed FTP password authentication dialog box, enter the FTP password. Then click
OK.

Figure 1-1 FTP password authentication

Step 7 Complete the configuration. If the system displays "Modified successfully!", click OK. If the system
displays "The password is incorrect!", enter the correct FTP password and click OK.
Table 1-1describes the procedure for upgrading the NodeB.

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 9
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

Table 1-1 Procedure for upgrading the NodeB


Step Description Reference Duration (for
Reference Only)
1 Setting loading control Error: Reference source not 1 minute
rights of a multimode base foundError: Reference source
station. not found
2 Query the NodeB software 1.6 Querying the Software
1 minute
status. Status of the NodeB
3 Upgrade the NodeB 1.7 Upgrading the BootROM
10 minutes
BootROM.
4 Upgrade the NodeB 1.8 Upgrading the NodeB
30 minutes
software. Software

CAUTION
ALM-26202 Board Overload alarm may be generated when:

Downloading the NodeB software package

Activating the NodeB software

Activating the board software
The alarm is automatically cleared after the upgrade.

1.6 Querying the Software Status of the NodeB


Query the software status of the NodeB by running the DSP SOFTSTATUS command.
 If the software status is displayed as Idle, the NodeB is idle and you can continue with
the upgrade process.
 If the software status is not displayed as Idle, other procedures such as software
supplementation and activation are in progress. When this occurs, wait until the
procedures are complete and then continue with the upgrade process.

1.7 Upgrading the BootROM

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 10
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

CAUTION
An unexpected reset of a board during the BootROM upgrade process may lead to damage to
the BootROM software or failure to start up the board. In this case, send the faulty board to
Huawei for maintenance.

NOTE

Download the V100R008C00SPC240 version file package, which contains the Firmware.csp, Software.csp, and vercfg.xml files, to a specified path. For details, see section 1.1.4

"Preparing the Upgrade Software Package.”

To upgrade the BootROM, perform the following steps:


Step 1 Log in to the LMT, and click Device Maintenance.
Step 2 On the left pane, choose Device Maintenance > BTS Maintenance.
Step 3 On the left navigation tree, double-click Software Management.
The Software Management tab page is displayed, as shown in Figure 1-1.

Figure 1-1 Configuring the FTP server

Step 4 In the FTP Server Configuration area, set FTP server associated parameters as follows:
 Set IP Address to the IP address of the LMT PC.
 Set User Name to the user name of the FTP server.
 Set Password to the password of the FTP server.
NOTE
Set User Name, Password, and File Path to the same values as those specified in section
1.5 "Confirming the FTP Status."

Step 5 Click the Upgrade BootROM tab and set the upgrade options on the displayed tab page as follows:
1. Select the Download BOOTROM and Activate BOOTROM check boxes.
2. Enter the BootROM package path (for example, D:\ftp\ BootROM) in the File path box,
as shown in
Figure 1-1.

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 11
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

Figure 1-1 Upgrading the BootROM

Step 6 Click Execute to start the upgrade.


A dialog box is displayed, indicating the status and progress of the BootROM upgrade. After the
BootROM package is activated, the boards that are activated and those failing to be activated are listed.
----End

1.8 Upgrading the NodeB Software

Assume that the software is successfully activated. After the base station is reset, the base
station automatically rolls back to the source version if the base station fails to connect to the
M2000 and no LMT logs in to the base station within 30 minutes.

Step 1 Log in to the LMT, and click Device Maintenance.


Step 2 On the left pane, choose Device Maintenance > BTS Maintenance.
Step 3 On the left navigation tree, double-click Software Management.
The Software Management tab page is displayed, as shown in Figure 1-1.

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 12
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

Figure 1-1 Configuring the FTP server

Step 4 In the FTP Server Configuration area, set FTP server associated parameters as follows:
 Set IP Address to the IP address of the LMT PC.
 Set User Name to the user name of the FTP server.
 Set Password to the password of the FTP server.
NOTE
Set User Name, Password, and File Path to the same values as those specified in section 1.5.2
"Configuring the FTP Server."

Step 5 In the Download and Active Software area, set upgrade associated parameters as follows:
1. Select Download Version Software and Activate Version Software check boxes.
2. (Optional)Select Download Configuration File and Activate Configuration File check
boxes.
3. When the UMPT works as the main control board, set Delay Download by Flag to
YES(Delay Download). When the WMPT works as the main control board, this option
does not exist.

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 13
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

NOTE
When Delay Download by Flag is set to YES(Delay Download), the upgrade duration shortens by
approximately 10 minutes. As a result, only the basic functions of the LMT are available after the
upgrade. However, LMT files will be automatically supplemented on the NodeB four hours after the
upgrade. If all LMT functions are required in an emergency, run the SPL SOFTWARE command
immediately after the upgrade completes.
By default, the NO(Do Not Supply Delay-Supported File) check box is selected, that is, LMT files are
not supplemented by default. LMT files can be supplemented only after the YES(Supply Delay-
Supported File) check box is selected.
4. Set Software Version to BTS3900 V100R008C00SPC260.

Figure 1-1 Downloading and activating the software

Step 6 Click Execute to start the upgrade, which takes about 40 minutes.

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 14
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

The upgrade process is displayed in the Message area. When the upgrade progress reaches
100% and the upgrade is successful, the NodeB resets and disconnects from the LMT PC.

After NodeB software is activated, the NodeB automatically resets which takes about four minutes (for
reference only), and the services are interrupted.

1.9 Querying the Active NodeB Version


Run the LST VER command on the LMT. Then, check whether the current software version
is BTS3900 V100R008C00SPC260.
Insert an local configuration file ( XML) using WEB LMT:
- By device maintenance interface:

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 15
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

By MML interface using commands:


- Download CFG FILE:

- Activate CFG FILE:

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 16
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

- Verify (after automatically reset) CFG FILE :

- Verify boards:

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 17
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

- Verify ETHPORT’s:

- Verify OMCH status:

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 18
Technologies Co., Ltd
Error! Use the Home tab to apply 标题 1 to the text
that you want to appear here.Error! Use the Home tab
to apply 标题 1 to the text that you want to appear
BTS3900 V100R008C00SPC260 (NodeB) Upgrade Guide here.

-END-

Huawei Proprietary and Confidential


01 (2013-12-27) Copyright © Huawei 19
Technologies Co., Ltd

You might also like