Professional Documents
Culture Documents
Introduction For more than 40 years, we have specialised in the optimisation of cabinet
Timing relays play an important role in many areas of plant and building infrastructures. Our wide range of relay modules, solid-state relays and additional
automation. They are always used when switch-on or switch-off processes value-added services combine the highest standards with ultimate quality. Less
are to be delayed or when short pulses are to be extended. They are wiring effort, housing optimisation through space saving, optimal marking and
used, for example, to avoid errors during short switching cycles that cost reductions – our customers challenges are our motivation. Our assortment
cannot be reliably detected by downstream control components. Timing impresses through reliability, longevity and safety.
relays are also a simple way of integrating timer functions into a system
without PLC, or implementing them without programming effort. Supplemented by our digital data support, switching load consulting and online
selection guides, we support our customers throughout the entire work process –
from the plan-ning phase to installation and operation.
So
s
TE lid el TE
ES le ES D-
ay
- s t a t e r el
s
RM ay RM SERIES
SERI modu SERI
On-delay 10
Off-delay 11
Clock generator 12
Star-Delta 13
Application
High sw
ncies
range m nc
y
Fu
Ti
it
ns
ns gn
Se
on
ue
TERMSERIES TIMER - Adjust control signals even more easily 14 pe
on
i
Si
al adapti in o t io n l saf
et
cial load or is olat ch q g functi
s
ing fre a Po w e r
2 3
Application range
Relay modules and solid-state relays for specific applications
With our application range we provide you with a customised portfolio to increase
your productivity, efficiency and safety in the most diverse fields of application.
What‘s more, we work with you to develop customised solutions, combining Sensor isolation Power
the advantages and features of our portfolio with our expertise and consulting Space-saving and fast switching Power solid-state contactor
services. coupling elements to decouple up to 75 A and miniature
sensors from the field. contactors up to 30 A.
We have a wide range of products that combine application-specific designs, the
latest technologies and well-proven components to meet all your requirements.
TE lid el TE
ES le ES D- required for signals in process
ay
- s t a t e r el
R
RM ay RM SERIES
SERI modu SERI
inductors and high inrush safety-related systems
currents, safely and reliably.
The following pages will guide you through our product range of
Application
High sw
ncies
time functions, show you their special features and are intended to
range m nc support you in making the right choice.
y
Fu
Ti
it
ns
ns gn
Se
on
ue
pe
on
i
Si
al adapti in o t io n l saf
et
ing fre a Po w e r
4 5
Reliable switch of timing functions Application examples of the timing relays
TFI-SERIES ‒ Reliable control of
• Temperature range
-25 °C to +60 °C
6 7
Multifunction
TFI-SERIES
Input Bp Clock generator pause first Bp Clock generator pause first E On-delay (V 2QGHOD\ZLWKFRQWUROLQSXW R Off-delay with control input
• Rated control voltage: 12 - 240 V UC
E On-delay
A1 / A2 A1 / A2 $$ A1 / A2
Output Es On-delay with control input
B1 / A2 B1 / A2 %$ B1 / A2
• Contact type: 1 changeover R Off-delay with control input
• Continuous current: 8 A LED U/T LED U/T /('87 LED U/T
Wa Single shot falling edge with control input
15 / 18 15 / 18 15 / 18
General Data Ws Single shot rising edge with control input T T T T T <T 7 7 T <T
• Installation design
• Status displays: Wu Single shot rising edge supply voltage controlled
Clock generator pause first (Bp) On-delay (E) On-delay with control input (Es) Off-delay with control input (R)
LED green (U/t): When the supply voltage U is applied, the set When the supply voltage U is applied, the set The supply voltage U must be constantly applied The supply voltage U must be constantly ap-
• Flashes when time runs interval t begins. After the interval t has expired, interval t begins. After the interval t has expired to the device. When the control contact S is plied to the device. When the control contact S
• Lights permanently with supply voltage is applied the output relay R switches into on-position and the output relay R switches into on-position. closed, the set interval t begins. After the inter- is closed, the output relay R switches into on-
LED yellow (R): the set interval t begins again. After the interval This status remains until the supply voltage is val t has expired the output relay R switches into position. If the control contact is opened, the set
• Relay closed t has expired, the output relay switches into off- interrupted. If the supply voltage is interrupted on-position. This status remains until the control interval t begins. After the interval t has expired
• Dimensions (W x H x D): 17.5 x 87 x 60 mm position. The output relay is triggered at a ratio before the expiry of the set interval, the interval contact is opened again. If the control contact the output relay switches into off-position. If the
• Temperature range: -25 °C to 55 °C of 1:1 until the supply voltage is interrupted. t already expired is erased and is restarted when is opened before the interval t has expired , the control contact is closed again before the set in-
• Connection: PUSH IN / Screw connection the supply voltage is next applied. interval already expired is erased and is restar- terval has expired, the interval already expired is
ted with the next cycle. erased and is restarted.
Time ranges
0.05 s - 1 s, 0.5 s - 10 s, 3 s - 60 s, 30 s - 10 min, 3 min - 1h,
30 min - 10 h, 5 h - 100 h
Single shot falling edge Single shot rising edge Single shot rising edge
1 Time setting with control input (Wa) with control input (Ws) supply voltage controlled (Wu)
2 Timescale The supply voltage U must be constantly applied The supply voltage U must be constantly ap- hen the supply voltage U is applied, the output
3 to the device. Closing the control contact S has plied to the device. When the control contact S relay R switches into on-position and the set
Timing function
no influence on the condition of the output R. is closed, the output relay R switches into on- interval t begins. After the interval t has expired
4 Status display (green): Supply voltage When the control contact is opened, the output position and the set interval t begins. After the the output relay switches into off-position. This
5 Status display (yellow): Relay closed relay switches into on-position and the set in- interval t has expired the output relay switches status remains until the supply voltage is inter-
terval t begins. After the set interval has expi- into off-position. During the interval, the control rupted. If the supply voltage is interrupted be-
red, the ouput relay switches into off-position. contact can be operated any number of times. A fore the interval t has expired, the output relay
During the interval, the control contact can be further cycle can only be started when the cycle switches into off-position. The interval already
operated any number of times. A further cycle run has been completed. is erased and is restarted when the supply vol-
can only be started when the cycle run has been tage is next applied.
completed.
8 9
On-delay Off-delay
TFI-SERIES TFI-SERIES
15 / 18 15 / 18
General Data T <T General Data T <T
• Installation design • Installation design
• Status displays: • Status displays:
LED green (U/t): LED green (U/t):
On-delay (E) Off-delay with control input (R)
• Flashes when time runs • Flashes when time runs
When the supply voltage U is applied, the set The supply voltage U must be constantly ap-
• Lights permanently with supply voltage is applied • Lights permanently with supply voltage is applied
interval t begins. After the interval t has expired plied to the device. When the control contact S
LED yellow (R): LED yellow (R):
the output relay R switches into on-position. is closed, the output relay R switches into on-
• Relay closed • Relay closed
This status remains until the supply voltage is position. If the control contact is opened, the set
• Dimensions (W x H x D): 17.5 x 87 x 60 mm • Dimensions (W x H x D): 17.5 x 87 x 60 mm
interrupted. If the supply voltage is interrupted interval t begins. After the interval t has expired
• Temperature range: -25 °C to 55 °C • Temperature range: -25 °C to 55 °C
before the expiry of the set interval, the interval the output relay switches into off-position. If the
• Connection: PUSH IN / Screw connection • Connection: PUSH IN / Screw connection
t already expired is erased and is restarted when control contact is closed again before the set in-
the supply voltage is applied next. terval has expired, the interval already expired is
Time ranges Time ranges
erased and is restarted with next cycle.
0.05 s - 1 s, 0.5 s - 10 s, 3 s - 60 s, 30 s - 10 min, 3 min - 1h, 0.05 s - 1 s, 0.5 s - 10 s, 3 s - 60 s, 30 s - 10 min, 3 min - 1h,
30 min - 10 h, 5 h - 100 h 30 min - 10 h, 5 h - 100 h
Type Connection VPE Order No. Type Connection VPE Order No.
TFIS 24-240VUC 1CO ON Screw connection 1 2697280000 TFIS 24-240VUC 1CO OFFC Screw connection 1 2697290000
TFIP 24-240VUC 1CO ON PUSH IN 1 2898340000 TFIP 24-240VUC 1CO OFFC PUSH IN 1 2898330000
3 3
1 1
4 2 4 2
10 11
Clock generator Star-Delta
TFI-SERIES TFI-SERIES
Input lp clock generator pause first li clock generator pulse first Input S star-delta
• Rated control voltage: 12 - 240 V UC • Rated control voltage: 12 - 240 V UC
A1 / A2 A1 / A2 A1 / A2
Output Output
B1 / A2 B1 / A2 LED U/T
• Contact type: 1 changeover • Contact type: 2 normally open
• Continuous current: 8 A LED U/T LED U/T • Continuous current: 3 A LED R
15 / 18 15 / 18 Y 17/18
General Data T1 T2 T1 T2 T1 T2 T1 T2 General Data
• Installation design • Industrial design Δ 17/28
T1 T2
• Status displays: Function lp with fixed jumper A1-B1 • Status displays:
LED green (U/t): LED green (U/t):
Clock generator pause first (Lp) Clock generator pulse first (Li) Star-Delta Start-up (S)
• Flashes slowly when time t1 runs • Flashes slowly when star-relay is closed, time t1 runs
When the supply voltage U is applied, the set When the supply voltage U is applied, the out- When the supply voltage U is applied, the star-
• Flashes quickly when time t2 runs • Lights permanently when delta-relay is closed
interval t1 begins. After the interval t1 has expi- put relay R switches into on-position and the set relay switches into on-position and the set star-
• Lights permanently when supply voltage is applied LED yellow (R)
red, the output relay R switches into on-position interval t1 begins. After the interval t1 has expi- time t1 begins. After the time t1 has expired the
LED yellow (R) • Star-relay closed
and the set interval t2 begins. After the interval red, the output relay switches into off-position star-relay switches into off-position and the set
• Relay closed • Dimensions (W x H x D): 22.5 x 67 x 75 mm
t2 has expired, the output relay switches into and the set interval t2 begins. After the interval transit-time t2 begins. After the time t2 has expi-
• Dimensions (W x H x D): 17.5 x 87 x 60 mm • Temperature range: -25 °C to 60 °C
off-position. The output relay is triggered at the t2 has expired, the output relay switches into red the delta-relay switches into on-position. To
• Temperature range: -25 °C to 55 °C • Connection: Screw connection
ratio of the both seted times until the supply vol- on-position. The output relay is triggered at the restart the function the supply voltage must be
• Connection: PUSH IN / Screw connection
tage is interrupted. ratio of the both seted times until the supply vol- interrupted and reapplied.
Time ranges
tage is interrupted.
Time ranges 0.05 s - 10 s, 1.5 s - 30 s, 3 s - 60 s, 9 s - 180 s
0.05 s - 1 s, 0.5 s - 10 s, 3 s - 60 s, 30 s - 10 min, 3 min - 1h,
30 min - 10 h, 5 h - 100 h
Type Connection VPE Order No. Type Connection VPE Order No.
TFIS 12-240VUC 1CO CG Screw connection 1 2697260000 TFIS 12-240VUC 2NO SD Screw connection 1 2697270000
TFIP 12-240VUC 1CO CG PUSH IN 1 2898310000
5
4
1
6 2 1
5 2
3
4
3
12 13
Adjust control signals even more easily
TERMSERIES TIMER
In preparation
Clear display
Due to the integrated Duo-LED
on the ejection lever, power
supply and switching status can
be checked at a glance.
14 15
Adjust control signals even more easily
TERMSERIES TIMER
On Delay One Shot
A1 / A2 A1 / A2
15 / 18 15 / 18 15 / 18 15 / 18 15 / 18
General Data T T T T T T T T
0,5s 0,5s
• 6 mm narrow design t< T t< T
• Status displays: *LED Or = LED Orange
LED Gn = LED Green
Duo-LED orange:
On Delay One Shot Blinker
• Lights permanently when relay closed Blinker Blinker
When the supply voltage A1/A2 is applied, the When the supply voltage A1/A2 is applied, the When the supply voltage A1/A2 is applied, the
Duo-LED green: Example: DIP switch adjustment for a on delay of 0.7 s
• Lights permanently when supply voltage is applied set time T begins
A1 / A2 A1 / A2
to run. When the time has set time T runs. After the time T has passed, the output relay 15/18 switches into on-position.
Function DIP switch passed, the output relay 15/18 switches into on- output relay 15/18 switches into on-position for After the set pulse time T has passed, the output
• Flashes in case of incorrect configuration, no function
Mode = On Delay 1 2 3 4 5 6 7 8 position.
LED Or* ThisLED state
Or* remains active until the sup- 0.5 s. After 0.5 s the output relay switches into relay switches into off-position. After the pause
• Dimensions (W x H x D): 6.4 x 90 x 88 mm
Time range = 0.1...1 s ply voltage isLED
interrupted. If the supply voltage is off-position. The time function is not restarted time T has passed, the output relay switches
• Temperature range: -20 °C to 60 °C LED Gn* Gn*
Time factor = 0.7 interrupted before time T has passed, the already until the next time the supply voltage is applied. into on-position again. The output relay is acti-
• Version: PUSH IN / Screw connection
• Connection: Relay modul/Empty socket run/ time
15 18 is deleted
15 / 18 and restarted with the next vated for the set time until the supply voltage is
application ofT supplyT TT
voltage. TT T T
interrupted. (T=pulse time=pause time)
= ON (DIP switch position) *LED Or = LED Orange
*LED Or = LED Orange
Time ranges
LED Gn = LED Green
LED Gn = LED Green
0.01 s - 0.1 s, 0.1 s - 1 s, 1 s - 10 s, 10 s - 100 s
T = Time factor x Time range (final value) | *LED Or = LED Orange | *LED Gn = LED Green
16 17
Compact timing relay for easy control signal adjustment
IT-TIMER
Multifunctional timing relay IT-TIMER with multi-voltage input Technical Data Timing functions
Timing relays are used in automation engineering in order to compensate for malfunctions caused
by high clock rates. Short pulses are extended and hence are reliably identified by downstream control
components. Various timing functions such as on- and off-delays and clock generator are available to Input A On-delay B Pulse emitter
users. • Rated control voltage: 24 - 48 V DC / 24 - 240 V AC
A1 / A2 A1 / A2
Output
With the IT-TIMER, Weidmüller offers a highly efficient, multifunctional timing relay with multi-voltage • Contact type: 1 changeover
B1 / A2 B1 / A2
input which fulfills the product standards according to EN 618121. • Continuous current: 5 A LED U/T LED U/T
15 / 18 15 / 18
General Data T T T T T
• Installation design
• Status displays:
LED green (U/t):
• Flashes when time runs
Your special advantages: • Lights permanently with supply voltage is applied
LED yellow (R):
C Passing make D Off delay
• Relay closed A1 / A2 A1 / A2
• High functionality Seven timing functions • Multifunction timing relays
Due to its multi-functional concept, • Dimensions (W x H x D): 17.5 x 98 x 57,9 mm B1 / A2 B1 / A2
and small footprint
the IT-TIMER covers a broad range of • Temperature range: - 25 °C to 50 °C
Due to the flat front panel, typcially needed time functions. • Connection: Screw connection
LED U/T LED U/T
18 19
Pulse stretcher
MCZ TO
With a width of 6 mm, the MCZ TO pulse stretcher is one of the slimmest of its kind Technical Data
These pulse stretcher are ideal for extending very short input pulses of < 10 ms in automation technology.
The extended pulses are passed on to the PLC inputs for further processing. Conventional timing relays Input
are not able to process very short input pulses. Such short pulses are generated e.g. by light barriers. • Rated control voltage: 24 V DC
• Status displays: LED green
Special features of the MCZ TO are:
Cross-connections Output
• No auxiliary voltages required for input or output • Contact type: 1 changeover (Transistor)
• Very short pulses ≥ 3.5 ms can be extended • Rated switching voltage: 5 - 48 V DC
• Continuous current: 20 mA
• Restart of the off-delay (watchdog) possible • Switch-off delay: 50 ms or 150 ms
• Very compact design
• Precisely fitting accessories: cross-connections, markers, end plate General Data
• Dimensions (W x H x D): 6.1 x 91 x 63.2 mm
• Temperature range: -25 °C to 50 °C
• Connection: Tension clamp
Timing functions
Off-delay
LED
• Identifies very short
input pulses (≥ 3,5 ms) 3/4
Out- / Out+ T <T T
• 6 mm width
Integrated reverse
polarity protection
20 21
The perfect match in engineering
Product data and configurator from Weidmüller
We understand data as a digital product from Weidmüller and set standards for Weidmüller provides you with all of the data, software tools and interfaces that you
our customers – high-quality and reliable, consistent and future-oriented. need throughout your processes - from electrical and mechanical planning, ordering
and production of configured products up to single products. No matter whether for
cabinet building, automation, building planning or printed circuit board design: we
offer you the solutions that accelerate your processes, tailored to your requirements.
eCl@ss
inside Engineering
Integrated engineering is the key to efficient product devel-
opment. This requires a combination of engineering tools that
can work together via interfaces and common data formats
and sources. High-quality product information is required for
planning in engineering systems such as Zuken or EPLAN.
Weidmüller makes this information available in all common
formats both in the data portals and on the Weidmüller
website for you to download.
ed Part
Selection guide for electromechanical relay modules
tifi
Our selection guide in digital and printed form support you in
r
ne
Ce
finding the right relay for safe and reliable switching of special
Co
m
ud
po o
nent Cl
loads:
www.weidmueller.com/relayselector
22 23
Weidmüller – Your partner in Smart Industrial Connectivity
As experienced experts we support our customers and partners around the world
with products, solutions and services in the industrial environment of power,
signal and data. We are at home in their industries and markets and know the
technological challenges of tomorrow. We are therefore continuously developing
innovative, sustainable and useful solutions for their individual needs. Together we
set standards in Industrial Connectivity.
All orders are based on our general terms of delivery, which can
be reviewed on the websites of our group companies where you
place your order. On demand we can also send the general terms
of delivery to you.