® G@?Excel Micro Computer Motor Protection Device Excellence through Innovation Why Micro Computer Electronic Over Load Relays are Preferred ? Precise estimate of the thermal image of motor for varying conditions of starting, running, overload, stopping, unbalance conditions. The negative sequence current calculations are taken into account for unbalance current conditions. Continuous monitoring of thermal capacity used and in case of power failure the last value of accumulated thermal capacity prior to power interruption is stored. © Six thermal overload curves - 2.5C, SC, 10C, 15C, 20 and 30C covering the complete range of motor applications as a regular feature in .LEDX-T, WeLEDX-T and wDLEDX-T ‘© Asa special feature 60 thermal overload curves 1C, 2C...60C for selecting exact curve for specific motor application is available in pHLEDX-T model Motor start lockout feature inhibiting start of the motor, in case of non-availability of sufficient thermal reserve to complete the acceleration. Automatic setting of parameters function, which would set all the protection parameters only on entering the rated full load current as per the motor name plate details. ‘© Annunciation, in case, the motor fails to stop after the protection device issues trip command. vw exceltechindia.com Gs Excel Motor Overload Protection is the optimum and accurate protection for motor in place of Over Current Definite Protection (fixed time delay setting) which is generally available in market. Overload tripping, using micro controller intelligent program is based on motor thermal overload characteristic curve. When the motor is overloaded, heating is based on thermal capacity used by the motor and tripping of the motor protection device is based on algorithm following thermal image of motor. Protection class Current Transformer (CT) + Device Combination provides accurate measurements for starting current (6 times full load current) and Short Circuit Protection ( 8 times full load current) Salient Features: ‘© LED Seven Segment Display, brighter pixilation and longer life than LCD. Continuous scanning and display of 3 phase currents and thermal capacity used ‘Annunciation for each type of fault Numerical Algorithm for fst, reliable operation ‘Thermal Overload curves selectable as per requirement, Excellent accuracy and long-time stability of thermal curves due to complete software-based implementation Customized protection class CT as per load requirement supplied with the relay Continuous self- supervision and fail-safe operation ‘Man-Machine interface through keypad. Upto five event trip records, FIFO based Reset Inhibit function, Hour Counter, Online / On site calibration, Start counter Robust mechanical design and shock proof non-metallic screw less unit. IP 54 degree of protection by enclosure, on front side of MPD (\LEDX-T / WHLEDX-T / weLEDX-T) MOTOR PROTECTION DEVICE Provides protection against : © Overload * Locked Rotor Short Circuit + Earth Fault Under Current + Single Phasing (Phase Loss) Unbalanced current Following protections/ functions are available based on selected variant of MPD : © Phase reversal ‘© ssR Output for Short Circuit Protection © Over Temperature (Thermistor Based) ‘© Data communication over MODBUS RTU protocol © Over Voltage & Under Voltage between Motor Protection level and higher-level ‘© bre-Trip Alarm for Overload or Definite time overcurrent * 4-20mA Analogue output ‘© PE, KW & KWH, KVA & KVAH measurement ‘Password Faclity stor sur ie 3 a Wiring Diagram OVER LOAD COLD CURVE CEL ALC LSE CE LISET TS 2 vera. excellechindia.com Annunciations : When the motor is running in healthy condition, the display scrolls R, Y and B phase currents and thermal capacity used (TCU). In case of fault, the display scrolls the type of fault, magnitude of fault and thermal capacity available (as per the thermal image for cooling of motor) The display of the annunciation for healthy condition and faults is as below : Model Healthy Condition overload Under Current Locked Rotor Short circuit Earth Fault ‘Single Phasing Unbalance Over Temp. Phase Reversal High Voltage Low Voltage Dry Run {only in wet EDx-1) [LEDX-T / PHLEDX-T |} eLEDX-T /|ILEDX-TVA, woo | pwio jLVPD Hoog|8$[rese[- caa]| “sees i . ar eo frau] egog] [sme |[eoool] “are HET YY Ossian |] oats ea | Rear 100 Feweo oan] | £100 |r oar] ns sc) ex] case’ fH mers |e uc Pa || br RD toxtes Resor ie gan jes| "ees" [fe ooo 60] [ewcemenn| |e O0 = —— St aT _fow| "sos" (ff eu £20] emeeeeon]| be [[ewemereeme lor ia By too & & 60 |” perro | on eee lo 8[ re Tr SPP aval SPP ot sala io B}— @ se | SPP SPP TBD |" rewcmenon | G0 |] won coo ———— ves Ub vas 3 ° tb Te at [OY [ow mmee 3 BD |” peem non Phor [Q9 | ssermenatte 3 TED |” rman a ane aro || an" Ht t 60 [eae a jso || ae lo +60 | meena deur || ovaunreue TED [femorcreers Note : WeLEDX-T display scrolls the following parameter values in heathy condition : Ir ly, 1B, Vey, Vrb, Vir, KWW, PF and KWH. eLEDX-TVA display scrolls parameter values similar to weLEDX-T except KW, PF and KWH. echindia.com Model: J HLEDX-T Model: WeLEDX-T Features: » LED seven segment four digit display » Display ofthe phase curents and thermal capacity used > Annunciation foreach type of fault » Numerical algorithm for fast and reliable operation » 25C, 5 10C,20¢ and 30¢ curves fr overload Protection » Protection ass CT (20,30, 55m) supplied withthe relay » Continuous self supervision and failsafe operation » Annunciation FAIL when motor falls to stop on trip command ' Man Machine interface through Keypads > Upto five event trip records » Reset inhibi function Hour Counter » Start Counter > Online Calbration Protection » Over Load » Under Cuerent » Unbolance current » Single Phasing » short Circuit » Locked Rotor » Earth Fault Features: In addition to features of yLEDX-T > True RMS Current measurement with 0A resoition > Faulthistory with real ime dock * Overcurrent range upto 1000 * Overload curves C, 2, 36. pto 60¢ Protection Inaddition to protection of wT * No. of stars protection Range Inaddition to range of EDT > 80t0500A * 1000 1000 (with 1000/5 cr Features: ‘In addition to features of wLEDX-T » Shc digit display » Voltage, Power factor, Power and Energy » (KWH, KVAH) measurement ‘True RMS current measurement with 0.2A resolution » Modbus RTU Protocol RS 485 » Over Voltage » Under Voltage » KW based Under load (Ory Run Protection) veww.excellechindia.com Optional Features : > Thermistor based Over temperature Foul story with realtime lock > 4-20mA output, RS 485 with Modbus TU Protocol Password Fatty SSR output for Shor Greut Protection Phase reversal Potertial ree external reset terminal ‘One extra NO/NC relay: Definite te overcuent protection (Pre-Alarm) Definite time overeuent protection (stead of Overload) Range + 0.29625 Amp * 04 w225 Amp * 081025 Amo » 210625Am0 » 410125 Amp » 4010250 Amp Optional Features : » Thermistor based Over temperature + 4-20 mA outout, RS. 485 with Modbus RTU Protocol » Password Facility » SSR output for Short Creu Protection » Potential ree external reset terminal » One extra NO/NC relay + Definite time overcurent protection (Pre-Aiacr) + Definite time overcurent protection (instead of Oveioad) Optional Features : » Thermistor based Over temperature » Fault history with realtime clock » 420 mA outout > Pessword Facity > Potent fre external reset terminal > One extra NO/NC relay + Definite ime overcurent protection (Pre-War) > Definite time overcurent protection (instead of Overioad) Range »o2to125A » aBto25A * 2106254 > ato asa » 40102508 Model: HDLEDx-T —_ Features: In addition to features of wLEDX-T » MPO with OWN rail mounting » Imbulle CT for upto 2 to 62.5A current range » Extemal CT for 4 to 125A and 40 to 250A current range Protection » Some as plEDe T Range » Same as ple T Features: In addition to features of wLEDXT » MPO with OIN rail mounting and detachable display console » Inbullt CT for upto 2 to 62.54 current range » External CT for 4 to 125A and 40 to 250A current range Protection > Some as EDT Range » Same as LEDE-T Optional Features : » Fault history with real tme clock » 4-20 mA output, Modbus RTU Protocol RS-485 + Password Faclity » Potential fro external reset terminal One extra NO/NC relay » Definite time overcurent protection (Pre-Alarm) » Definite time overcurent protection (Instead of Overload) Optional Features : > Fault history with realtime clock » 4.20 mA outout, Modbus RTU Protocol RS 485 Password Facility Potential fee external reset terminal One extra NO/NC relay Definite time overcurent protection (Pre-Warm) » Detinite time overcurent protection (instead of Overioad) Features: {In addition to features of wLEDx-T Optional Features: » Thermistor based Over temperature » Sixdigit display > Fault history with realtime clock > Display of tree phase votag » 4.20 mA output, Modbus RTU Protocol (oii ee pares | Protection + Password Faclity Imadaition to protection of uLEDx-T + Potential fre external reset terminal Over Voltage » One extra NO/NC relay > Under Vottage » Definite time overcurent protection Range (Pre-aiarm) > Same as yLEDE-T » Definite time overcurent protection (instead of Overioad) Modet: woD Features: Protection » DIN all mounting without display > Numerical Algorithm for fast and reliable operation, > Protection class CT inbuilt inthe relay » Fixed Overload curve of SC (Hot curve) » Indicates the type of fault through LED > Continuous self supervision and fall safe operation » Potential free ext. rset terminal Features: > DIN ral mounting with display > Numerical Algorithm for fast and reliable operation > Protection class CT inbuilt inthe relay > Selectable Overioad curve of 25C, SC and 10¢ > Indicates the type of fault through display Continuous self supervision and fal safe operation Reset Inhibit delay Potential free ext. reset terminal Star-Delta c/o relay with time setting (Optional) 5 ‘worwexceltechindia.com * Overload with inverse curve or ver current wih definite time » Under curent > Single phasing * Untiance Protection (Wot avatable with overcurent) Range 110204 Protection wooo » Overload with inverse cnve or over current with definite time » Undercurrent > Single phasing » Unbalance Protection » Earth fault Range * 110288 Model :HVPD Features: Protection Range > LED Seven Segment Display High voltage > 10010500 » pemunclation indicates the type of Ful. » Low votage » Modbus RTU Protocol RS 485 (optional) * Single Phasing » Unbatance votage » Phase Reversal » arth aul » Thermietor Protection (Optional) @0e60 Model: INTELLIGENT MD Features: Optional Features : SEG In addition to features of uLEDx-T + 4-20-mA output RS 485 with Modbus a » energy saver features TU protocol » Energy saving by delta to star changeover during Password Faclity low lad, start delta change over during high oad > Definite time overcurent protection Individual faule annuneiation (instead of Overload > Man machine interface through keypad & display Protection Range » Sameas uLEOx-T » Same as uLED«-T (CLIC LOAD ENERGY SAVER. HLEDx-Ti Series The Motor Protection Device, uLEDx-T and weLEDx-T is made intell control functions into the protection device and designated as uLEDx-Ti & weLEDx-Ti, ‘Apart from the moter protection, metering and monitoring functions, the device can accept four hardwired digital inputs (potential free contact signals) which can be used for Start, Stop, Emergency Stop and Local/ Remote (Auto/ Manual) control selection. These input commands ‘can also be transmitted to the remote control room through RS485 communication network. ‘The device has three output relay potential free contacts, One relay with change-over contact (NO/NC} and two relays with NO contacts, which are pre-programmed for starter logics for DOL starter, Star delta Starter, Soft Starter or can be configured by user for control logics in SCADA. ‘The Pre-programmed starter logics for control of DOL Contactor, Star Delta contactors or Soft Starter reduce manufacturing cost due to reduction in related physical wiring and the ‘commissioning time. ® = mw t04) © Excel Tech incia Pvt. L1D,- 992/1/17, GIDC, Nr. Shri Gayatrikrupa Ice Factory, Makarpura, Vadodara - 390 010. GUJARAT, INDIA. Pith +91 7862084856, 7567093806, 9376222606 ere marketing exceltechindia@gmail.com ( sales@exceltechindia.com rrpeayrers « exell2003@yahoo.com ree NS CEs | kn somn ans www.exceltechindia.com exo couran

You might also like