You are on page 1of 4

1

Accueil Réseau Offres d’emploi Messagerie Notifications Vous Pour les entreprises Publier une offre d’emploi

WHAT ARE THE


PERFORMANCE LEVELS
OF DIESEL
GENERATORS?
Esperanza Lin
Sales and Marketing Specialist about Power 20 articles Suivre
Station

2 août 2022

Ouvrir le lecteur immersif

With the continuous improvement of the quality and


performance of domestic and international diesel generator
sets, generator sets are widely used in hospitals, hotels,
hotels, real estate and other industries. The performance
levels of diesel power generator sets are divided into G1, G2,
G3, and G4.

Class G1: The requirements of this class apply to connected


loads that only need to specify the basic parameters of their
voltage and frequency. For example: General use (lighting
and other simple electrical loads).

Class G2: This class of requirements applies to loads that


have the same requirements for their voltage characteristics
as the public power system. When the load changes, there
may be temporary but allowable deviations in voltage and
frequency. For examples: lighting systems, pumps, fans and
winches.

Class G3: This level of requirements applies to connected


equipment that has strict requirements on the stability and
level of frequency, voltage and waveform characteristics. For
examples: radio communications and thyristor controlled
loads. In particular, it should be recognized that special
considerations are required regarding the effect of the load
on the generator set voltage waveform.

Class G4: This class is applicable to loads with particularly


stringent requirements on frequency, voltage, and waveform
characteristics. For example: Data processing equipment or
computer system.

As a communication diesel generator set for telecom project


or telecommunication system, it must meet the requirements
of G3 or G4 level in GB2820-1997, and at the same time, it
must meet the requirements of 24 performance indicators
specified in the “Implementation Rules for Network Access
Quality Certification and Inspection of Communication
Diesel Generator Sets” and strict inspection by the
Communication Power Equipment Quality Supervision and
Inspection Center established by Chinese industry authorities.

Signaler ceci

Publié par

Esperanza Lin
Sales and Marketing Specialist about Power Station 20 articles Suivre
Publié • 1 an

The performance levels of diesel power generator sets are divided into G1, G2, G3,
and G4. As a communication diesel generator set for telecom project or
telecommunication system, it must meet the requirements of G3 or G4 level in
GB2820-1997, and at the same time, it must meet the requirements of 24
performance indicators specified in the “Implementation Rules for Network Access
Quality Certification and Inspection of Communication Diesel Generator Sets” and
strict inspection by the Communication Power Equipment Quality Supervision and
Inspection Center established by Chinese industry authorities. Los niveles de
rendimiento de los grupos electrógenos diésel se dividen en G1, G2, G3 y G4. Como
grupo electrógeno diesel de comunicación para proyectos de telecomunicaciones o
sistemas de telecomunicaciones, debe cumplir con los requisitos de nivel G3 o G4 en
GB2820-1997 y, al mismo tiempo, debe cumplir con los requisitos de 24 indicadores
de rendimiento especificados en las "Reglas de implementación para Certificación de
calidad de acceso a la red e inspección de grupos electrógenos diésel de
comunicación” e inspección estricta por parte del Centro de inspección y supervisión
de calidad de equipos de energía de comunicación establecido por las autoridades
industriales chinas. #dieselgenerator #g2 #g3 #g4 #g1 #genset #dieselgenset
#dieselgeneratorset #generatorset #communication #telecommunications
#powerstation #powersupply #powergen #powergenerator #gruposelectrogenos
#telecomunicaciones #generadores #generadoreselectricos #generators
#generator #telecomproject #telecom #energía #power

J’aime Commenter Partager 12 1 commentaire

Réactions

1 commentaire
Les plus pertinents

Ajouter un commentaire…

Moussa Ahmed • + que 3e 11 mois


Data Center Project Manager

great

J’aime Répondre

Esperanza Lin
Sales and Marketing Specialist about Power Station

Suivre

Plus de Esperanza Lin

WHAT ARE DIFFERENCES WHICH ARE FEATURES OF


BETWEEN GASOLINE DIESEL DC GENERATOR SET?
OUTBOARD ENGINE AND…
Esperanza Lin sur LinkedIn
Esperanza Lin sur LinkedIn

MOBILE EMERGENCY POWER


SUPPLY VEHICLE

Esperanza Lin sur LinkedIn


Voir les 20 articles

You might also like