NON CONFORMITY REPORT

NCR INFO
NCR Number 200002591 Non Conformity Type Z2 Reference
Required Start 2023-11-29 Required End 2023-12-29
Company AT59 Danieli Eng & Serv GmbH
Sales Order / Item /

NCR DESCRIPTION
The surface where the assembly indicate the O-Ring is machined wrong, consequently the O-Ring will be inefficient (see picture
2591_4).
On the drawing F:7 the rounding of the screw edges is missing.
On the drawing B:1 the M75x2 thread is not running.
On the drawing A:1 the coaxility should be 0.02mm, but we measured 0.21.
On the drawing F:1 the slot should be 10H9 (+0,036;0), but we measured 9.99mm.

NCR DETAIL
Plant AT10 Rev. Complaint Qty 1 PC
Purchaising Document / Item 4500006308 / 10 Product Order Batch 1000048781
Item 4.055906.Z WORM SCREW
Supplier 1000002206 GREBEN DOO
Buyer 113 SMRTNIK NIKO
Expediter 8693

ACCEPTED AS IS
Accepted as is NO
Accepted as is Notes

SUGGESTION RESOLUTION
Please pick up the piece with highest priority and exchange!
Inform us about the repair and delivery time.
Any transport costs will be charged back to you.