You are on page 1of 34

Technology for Life

Medical SYSTEMS
Technology for Life

≥ BIOMedical refrigeration
≥ Blood safety
≥ Biotech systems www.dometic.lu
Dometic Medical Systems – Technology for life
The division “Medical Systems” of Dometic S.à r.l. is specialized in research, development and manufacturing of
professional refrigerators & deep freezers, storage & transport concepts, high quality instruments & equipment
for laboratories, medicine, research, biotechnology and Life Science.

Dometic places its expertise in medical refrigeration and its excellent knowledge of user needs at the service of
humanity. The results is the concept ”Technology for life” which has determined the development of the “Medical
Systems” product range.

Our expertise in this area goes back to the year 1979, when the product range “Cold Chain” was selected by the
international health organization to ensure the effectiveness of the cold chain for vaccines worldwide.

Since then Dometic Medical Systems has established a worldwide distribution network and is nowadays
recognized as a reliable and professional partner in the medical world. It has a history of close co-operation with
prestigious international organizations, institutions and companies.

Dometic focuses on the client’s absolute right to precision, reliability, durability, functionality and design, with easy
access to support, service and training.

We are committed to high quality, safety, compliance to standards and are environmentally responsible.

Biomedical
Refrigeration Blood Safety Biotech Systems

Page 03 – 20 Page 21 - 29 Page 30 - 32

02 | 03
Biomedical Refrigeration

Biomedical Refrigeration
Innovative and reliable
refrigeration solutions
Dometic’s Biomedical Refrigeration product range is the solution
for safe storage, transport & handling of temperature sensitive
preparations in the appropriate optimum conditions without any
risks.
The products cover the spectrum of the specific and exacting needs
of the market: hospitals, laboratories, pharmacies, blood banks,
research centres, universities and industry.

Dometic Safety and Green Standards


For technical reliability and environmental friendliness

Biomedical refrigerators, freezers and


transport systems
For any cooling need in laboratories, research, d
biotechnology

Dometic Electronic & Software


For optimum control and protection of your preparations

Comprehensive accessories program


Please contact us to know more about our wide range of
drawers, shelves and racks

Technology for Life


Gold & Silver Safety Standards

The Safety Standards developed by Dometic define certain significant


technical features of a product. These ensure the safe storage of the
preparations as well as the trend-setting safety of the user.

The Dometic Silver Safety Standard ensures the reliable and safe operation of all
Dometic Dometic
Dometic refrigerators and deep freezers. Safety for the stored preparations and
the user. Silver models are denominated with a “S”.

The Dometic Gold Safety Standard efficiently complements the safety require-
safety safety
ments of the Dometic Silver Safety Standard and therefore exceeds even the standard standard
GOLD Silver
official standards. Gold models are denominated with a “G”.

Dometic Electronic 1

Safety door lock with 2 keys


Key-operated power switch (power ON/OFF) with 2 keys
Power indicator light
Digital temperature indicator (display: 0.1 digits)
Controlled fan cooling system for constant temperature and even temperature distribution across the entire refrigerating
chamber. Automatic switch-off when front door opens 2
Self-contained alarm system with integrated battery takes over the alarm function and temperature value measurements
in case of power failure for at least 48 hours 1
Acoustic and visual alarm signal in case of temperature alarm and power failure
The alarm history on the electronic stores all the relevant values during a temperature alarm, such as: min., max. and
average temperature & also the duration of the alarm 1
Remote transmission alarm signal (via potential-free contact) in case of temperature alarm (change-over contact)
Control via self-diagnostic system
Safety thermostat prevents dropping of the cold storage product’s temperature below +2°C 3

Door opening alarm (visual / acoustic)


Designed and tested for climatic class SN / T (ambient temperature range +10°C to +43°C) 4 –
Designed and tested for climatic class SN (ambient temperature range +10°C to +32°C) 8 –
RS 485 interface for the visualization of all operating and control functions (hardware and software settings) via DMN
monitoring software on a peripheral device (computer) 1
Interior made from stainless stee –
Internal LED lighting 6

Smooth castors for optimum flexibility of movement 5 –


GMP Clean Room Classification for free standing installation: in clean rooms of GMP A / ISO 5 (ISO EN 14644-1) 7 –
GMP Clean Room Classification for free standing installation: in clean rooms of GMP B / ISO 6 (ISO EN 14644-1) –
Additional remote transmission alarm signal (via potential-free contact) in case of power failure (change-over contact)
External water cooling 5 –
DMN - Dometic Monitoring Network 1

Ambient temperature sensor


DCU - Dometic Communication Unit

standard optional – not available


1
Not for underbench models ML / MP 135 SG 4
Models FR 110 GG – 750 G, UF 455 G/GG & UF 755 G/GG 7
 odel range UF conform to the GMP Clean Room Class B
M
2
Not for models UF 455 G/GG & UF 755 G/GG, FR 110 GG designed and tested for climate class SN (cleaning cycles according to the
and MF 110 SG/ 250 S (ambient temperature range +10°C to +32°C) operator’s hygiene plan must be scheduled and observed)

3
For refrigerators
5
Not for models BR/ FR/ LR/ PR 110 G/GG 8
 odels ML for climatic class SN/ST
M
6
For model ranges BR, LR and PR only, optional for model (ambient temperature range +10°C to +38°C)
ranges ML and MP only

04 | 05
Green Standard

Green light for real sustainable cooling technology

Dometic Medical Systems’ concept “Technology for Dometic Medical Systems is pleased to announce a
life” affects not only humans, but also our environment complete new range of high efficient and low noise
that is the base for all life. Hence we have committed appliances using natural gases such as isobutane,
ourselves to the radical minimization of our products’ propane and ethane as refrigerants.
CO2 output.

These new “green” models convince by their technical optimizations in terms


of economy and environmental protection:

Use of environmentally friendly, natural gases


 In addition, the new models stand out
as refrigerants accompanied by enormous be­­cause of :
reduction of CO2 emissions Improved hold over times thanks to optimized


40-60 % less energy consumption door insulation

Over 80 % less heat ejection Drastically reduced noise level for more
workplace convenience
Up to 40 % less power needed

Green Standards
Dometic

Environmentally friendly refrigerants

Reduced energy consumption

Reduced CO2 emission


GREEN
standard Less heat ejection

Less power needed

“Green” models are denominated as “SG” (Silver & Green ) or “GG” (Gold & Green ).

Technology for Life


+4°C I Dometic BR

BR range

BR 110 G/GG BR 250 G/GG BR 410 G/GG BR 490 G/GG BR 750 G/GG

Refrigerators for the legally safe storage of


blood bags / erythrocyte concentrates at +4°C
(according to DIN 58371 & ÖNORM K 2030)

The interior temperature of the blood refrigerators is monitored via an


Dometic Dometic
autonomous control sensor and adjusted to +4°C. This ensures that the
product temperature of the stored preparations is kept at +4°C ± 1.5°C.

The models of the BR range feature a natural defrosting system that does safety
standard GREEN
not affect the product temperature of the stored preparations during GOLD standard

defrosting.

BR models are equipped with glass door for quick check and pre-selection
of the refrigerator‘s content.

The transparent front panel of the ST-Drawers, which are part of the
standard equipement of the BR models, minimize cold losses when the
door is opened.

Models BR 250 G – 750 G are available as 220-240 V (50/60 Hz) and 115 V
(60 Hz) version, model BR 110 G only as 115 V (60 Hz) type. All green models
exist as 220-240 V (50 Hz) version.

All 450 ml blood or plasma bags are always filled with approx. 350 ml, all 350 ml bags with approx. 250 ml. The number of bags are estimated. The real number
06 | 07 depends on the different bag manufacturers’ specifications available on the market, on the actual bag sizes as well as on the individual user’s practice of loading.
Blood Bank Refrigerators I +4°C

BR 110 G / GG BR 250 G / GG

BR 110 G BR 110 GG BR 250 G BR 250 GG


External dimensions (mm) 820 x 560 x 580 External dimensions (mm) 1305 x 850 x 785
Gross volume (l) 106 Gross volume (l) 246
Net volume (l) 92 Net volume (l) 167
Storage capacity 54 at 450 ml each Storage capacity 120 at 450 ml each
(blood bags) 72 at 350 ml each (blood bags) 160 at 350 ml each

Energy consumption 1.25 0.75 Energy consumption 1.50 0.95


(Kwh/24h) (40 % less) (Kwh/24h) (37% less)

Noise level (dB(A)) 41 Noise level (dB(A)) 49 42

BR 410 G / GG BR 490 G / GG BR 750 G / GG

BR 410 G BR 410 GG BR 490 G BR 490 GG BR 750 G BR 750 GG


External dimensions (mm) 1735 x 850 x 785 External dimensions (mm) 1950 x 850 x 785 External dimensions (mm) 1990 x 910 x 985
Gross volume (l) 408 Gross volume (l) 489 Gross volume (l) 746
Net volume (l) 319 Net volume (l) 395 Net volume (l) 620
Storage capacity 240 at 450 ml each Storage capacity 300 at 450 ml each Storage capacity 450 at 450 ml each
(blood bags) 320 at 350 ml each (blood bags) 400 at 350 ml each (blood bags) 550 at 350 ml each

Energy consumption 1.70 1.00 Energy consumption 1.90 1.10 Energy consumption 2.00 1.20
(Kwh/24h) (41% less) (Kwh/24h) (42% less) (Kwh/24h) (40% less)

Noise level (dB(A)) 51 42 Noise level (dB(A)) 51 42 Noise level (dB(A)) 51 42

Technology for Life


+5°C I Dometic ML / MP

ML (solid door range)

ML 355 S

ML 320 S
ML 360 CS ML 580 S ML 1300 S
ML 155 SG

Refrigerators for the storage of laboratory and


pharmaceutical preparations being subject to cold
chain and temperature sensitivity
(according to DIN 58345)

The product range ML/MP offers volumes from 155 to 1301 litres including Dometic Dometic

one combined refrigerator/ freezer model.

MP models are equipped with glass door for quick check and pre-selection
of the refrigerator’s content. ML models are equipped with solid door. safety
standard GREEN
Silver standard
Being in conformity with the Dometic Silver Safety Standard these models
ensure a reliable and safe operation.

MP (glass door range)

MP 355 S

MP 320 S
MP 360 CS MP 580 S MP 1300 S
MP 155 SG

08 | 09
Laboratory / Medicine / Pharmaceutical Refrigerators I +5°C

ML / MP 155 SG ML / MP 320 S ML / MP 355 S

fig. MP 155 SG fig. MP 320 S fig. MP 355 S

ML 155 SG / MP 155 SG ML 320 S / MP 320 S ML 355 S / MP 355 S


External dimensions (mm) 900 x 595 x 630/605 External dimensions (mm) 1830 x 595 x 605 External dimensions (mm) 1690 x 700 x 616
Gross volume (l) 155 Gross volume (l) 322 Gross volume (l) 353
Net volume (l) 141 Net volume (l) 274 Net volume (l) 340
Energy consumption 0.54 0.76 Energy consumption 1.10 1.60 Energy consumption 1.41 1.86
(Kwh/24h) (Kwh/24h) (Kwh/24h)

Noise level (dB(A)) 41 41 Noise level (dB(A)) 42 42 Noise level (dB(A)) 44 44


ML 155 SG available as Internal II 3 G EEx nA II T6 ML 320 S available as Internal II 3 G EEx nA II T6

ML / MP 360 CS ML / MP 580 S ML / MP 1300 S

fig. MP 360 CS fig. MP 580 S fig. MP 1300 S

ML 360 CS / MP 360 CS ML 580 S / MP 580 S ML 1300 S / MP 1300 S


External dimensions (mm) 2030 x 595 x 605 External dimensions (mm) 1980 x 750 x 800 External dimensions (mm) 1980 x 1500 x 800
Gross volume (l) 357 Gross volume (l) 578 Gross volume (l) 1301
Net volume (l) 324 Net volume (l) 518 Net volume (l) 1183
Refrigerator Freezer
Energy consumption 1.10 / 1.38 2.60 Energy consumption 3.00 3.50 Energy consumption 3.10 5.50
(Kwh/24h) (Kwh/24h) (Kwh/24h)

Noise level (dB(A)) 42 43 Noise level (dB(A)) 47 47 Noise level (dB(A)) 50 50

Technology for Life


+4°C I Dometic LR / PR

LR (solid door range)

LR 110 G/GG LR 250 G/GG LR 410 G/GG LR 490 G/GG LR 750 G/GG

Refrigerators for the storage of laboratory and


pharmaceutical preparations being subject to cold
chain and temperature sensitivity (according to DIN 58345)
The product range PR/LR offers volumes from 106 to 746 litres. PR models are equipped
Dometic Dometic
with glass door for quick check and pre-selection of the refrigerator’s content. LR models are
equipped with solid door.
The transparent front panels of the ST-Drawers, which are part of the standard equipment of
the PR models, minimize cold losses when the door is opened. safety
standard GREEN
GOLD standard
Being in conformity with the Dometic Gold Safety Standard these models even exceed official
safety standards.
Models PR/LR 250 G – 750 G are available as 220-240 V (50/60 Hz) and 115 V (60 Hz)
version, models PR and LR 110 G only as 115 V (60 Hz) type. All green models exist as 220-
240 V (50 Hz) version.

PR (glass door range)

PR 110 G / GG PR 250 G/GG PR 410 G/GG PR 490 G/GG PR 750 G/GG

10 | 11
Laboratory / Medicine / Pharmaceutical Refrigerators I +4°C

LR / PR 110 G / GG LR / PR 250 G / GG

fig. PR 110 G / GG fig. PR 250 G/GG

LR / PR 110 G LR / PR 110 GG LR/PR 250 G LR/PR 250 GG


External dimensions (mm) 820 x 560 x 580 External dimensions (mm) 1305 x 850 x 785
Gross volume (l) 106 Gross volume (l) 246
Net volume (l) 92 Net volume (l) 167
Energy consumption 1.15 / 1.25 0.75 Energy consumption 1.40 / 1.50 0.90 / 0.95
(Kwh/24h) (35 / 40% (Kwh/24h) (36 / 37%
less) less)
Noise level (dB(A)) 41 Noise level (dB(A)) 49 42
LR 110 GG available as Internal II 3 G EEx nA II T6

LR / PR 410 G / GG LR / PR 490 G / GG LR / PR 750 G / GG

fig. PR 410 G/GG fig. PR 490 G/GG fig. PR 750 G/GG

fig. PR 410 GG fig. PR 410 GG

LR/PR 410 G LR/PR 410 GG LR/PR 490 G LR/PR 490 GG LR/PR 750 G LR/PR 750 GG
External dimensions (mm) 1775 x 850 x 785 External dimensions (mm) 1950 x 850 x 785 External dimensions (mm) 1990 x 910 x 985
Gross volume (l) 408 Gross volume (l) 489 Gross volume (l) 746
Net volume (l) 319 Net volume (l) 395 Net volume (l) 620

Energy consumption 1.60 / 1.70 0.95 / 1.00 Energy consumption 1.80 / 1.90 1.00 / 1.10 Energy consumption 1.90 / 2.00 1.10 / 1.20
(Kwh/24h) (41% less) (Kwh/24h) (44 / 42% (Kwh/24h) (42 / 40%
less) less)

Noise level (dB(A)) 51 42 Noise level (dB(A)) 51 42 Noise level (dB(A)) 51 42

LR 490 G/GG available as Internal II 3 G EEx nA II T6

Technology for Life


–41°C / –35°C I Dometic FR / MF

FR/MF range

FR 110 G/GG FR 250 G FR 410 G FR 490 G FR 750 G MF 110 SG MF 250 S

Freezers for the low-temperature storage of plasma


and other substances under optimum conditions
(according to DIN 58375)

Dometic Dometic Dometic


Dometic’s Biomedical Freezer range is the perfect solution for a safe
storage and handling of temperature-sensitive preparations such as plasma
and other blood products in conformity with national and international
norms and guidelines. safety safety
standard GREEN standard
GOLD standard Silver
Models FR 250 G – 750 G are available as 220-240 V (50 Hz) and 115 V (60
Hz) version, model FR 110 G only as 115 V (60 Hz) type. The green model FR
110 GG as well as the MF models exist as 220-240 V (50 Hz) version.

FR 110 G / GG FR 250 G

FR 110 G FR 110 GG FR 250 G


External dimensions (mm) 820 x 560 x 580 External dimensions (mm) 1305 x 850 x 785
FR range Gross volume (l) 106 Gross volume (l) 246
Net volume (l) 104 Net volume (l) 167
FR models comply with the
Dometic Gold Safety Standard Storage capacity 54 at 450 ml each Storage capacity 120 at 450 ml each
(plasma bags) 72 at 350 ml each (plasma bags) 160 at 350 ml each
and even exceed official safety
standards. Energy consumption pending 4.00 Energy consumption 6.10
(Kwh/24h) (Kwh/24h)

Noise level (dB(A)) pending 47 Noise level (dB(A)) 58

All 450 ml blood or plasma bags are always filled with approx. 350 ml, all 350 ml bags with approx. 250 ml. The number of bags are estimated. The real number
12 | 13 depends on the different bag manufacturers’ specifications available on the market, on the actual bag sizes as well as on the individual user’s practice of loading.
Deep Freezers & Plasma Storage Freezers I –41°C / –35°C

FR 410 G FR 490 G FR 750 G

FR 410 G FR 490 G FR 750 G


External dimensions (mm) 1735 x 850 x785 External dimensions (mm) 1950 x 850 x 785 External dimensions (mm) 1990 x 910 x 985
Gross volume (l) 408 Gross volume (l) 489 Gross volume (l) 738
Net volume (l) 319 Net volume (l) 395 Net volume (l) 620
Storage capacity 240 at 450 ml each Storage capacity 300 at 450 ml each Storage capacity 450 at 450 ml each
(plasma bags) 320 at 350 ml each (plasma bags) 400 at 350 ml each (plasma bags) 550 at 350 ml each
Energy consumption 7.40 Energy consumption 7.80 Energy consumption 7.10
(Kwh/24h) (Kwh/24h) (Kwh/24h)

Noise level (dB(A)) 58 Noise level (dB(A)) 58 Noise level (dB(A)) 58

MF 110 SG MF 250 S

MF 110 SG MF 250 S
External dimensions (mm) 900 x 595 x 630 External dimensions (mm) 1830 x 595 x 605
Gross volume (l) 110 Gross volume (l) 247
MF range Net volume (l) 104 Net volume (l) 228
Storage capacity 69 at 450 ml each Storage capacity 168 at 450 ml each
Being in conformity with the (plasma bags) (plasma bags)
69 at 350 ml each 168 at 350 ml each
Dometic Silver Safety Standard
Energy consumption 1.70 Energy consumption 2.50
MF models always ensure a (Kwh/24h) (Kwh/24h)
reliable and safe operation.
Noise level (dB(A)) 41 Noise level (dB(A)) 44
Conform with Internal II 3 G EEx nA II T6 Conform with Internal II 3 G EEx nA II T6

Technology for Life


–86°C I Ultra Deep Freezers I UF

Ultra Deep models for


freezing down to –86°C

The models UF 455 G/GG & UF 755 G/GG reflect the highest and most uncompromising Dometic Dometic

requirements in state-of-the-art technology and economy.

The cooling system is optimally designed with respect to energy consumption as well as to
the development of waste heat and noise. safety
standard GREEN
GOLD standard
The UF 755 GG can definitely be denominated as the Ultra Deep Freezer with the lowest
energy consumption on the whole market (compared with products with the same internal
temperatures and volume).

UF 455 G / GG UF 755 G / GG
Evaporator
Technology
Innovative “Rollbond” evaporator
technology of the highest grade
(stainless steel) for constant temperatures
and uniform temperature distribution.

UF 455 G UF 455 GG UF 755 G UF 755 GG


External dimensions (mm) 1450 x 910 x 950 External dimensions (mm) 1990 x 910 x 950
Gross volume (l) 453 Gross volume (l) 753
Net volume (l) 440 Net volume (l) 733
Storage capacity 270 at 450 ml each Storage capacity 450 at 450 ml each
(plasma bags) 330 at 350 ml each (plasma bags) 550 at 350 ml each
Energy consumption 17.50 12.00 Energy consumption 19.00 13.00
(Kwh/24h) (31% less) (Kwh/24h) (32% less)

Noise level (dB(A)) 59 53 Noise level (dB(A)) 60 54

All 450 ml blood or plasma bags are always filled with approx. 350 ml, all 350 ml bags with approx. 250 ml. The number of bags are estimated. The real number depends
14 | 15 on the different bag manufacturers’ specifications available on the market, on the actual bag sizes as well as on the individual user’s practice of loading.
MBF I High Performance Contact Shock Freezers I –50°C

Horizontal contact shock freezing technology for blood


plasma, biological and pharmaceutical preparations

Dometic’s High Performance Contact Shock Freezers are designed for the fast freezing of blood plasma, biological and
pharmaceutical preparations to a core temperature of –30°C.

MBF models are built in compliance with directives for the preparation of blood plasma.

MBF 12
Principle / Mode of operation

Contact cover plate


fixed, separately controlled

MBF 12
8 plasma bags at 1000 ml (content 850 ml)
12 plasma bags at 500 ml (content 450 ml)
Freezing time to core temperature of 12 units (500 ml) ~ 40 min
–30°C 8 units (1000 ml) ~ 55 min

Contact operating plate adjustable, separately controlled Operating temperature (preset), reached –50°C (upper & lower contact plate)
within ~ 20 min (pre-cooling phase)

External dimensions (mm) 1600 x 970 x 770

MBF 21 MBF 42

MBF 21 MBF 42
14 plasma bags at 1000 ml (content 850 ml) 28 (2 x 14) plasma bags at 1000 ml (content 850 ml)
21 plasma bags at 500 ml (content 450 ml) 42 (2 x 21) plasma bags at 500 ml (content 450 ml)
Freezing time to core temperature of 21 units (500 ml) ~ 40 min Freezing time to core temperature of 42 units (500 ml) ~ 40 min
–30°C 14 units (1000 ml) ~ 55 min –30°C 28 units (1000 ml) ~ 55 min

Operating temperature (preset), reached –50°C (upper & lower contact plate) Operating temperature (preset), reached –50°C (upper & lower contact plate)
within ~ 20 min (pre-cooling phase) within ~ 20 min (pre-cooling phase)

External dimensions (mm) 1600 x 1470 x 770 External dimensions (mm) 1920 x 1900 x 770

Technology for Life


Built-in & Sub-assembly Models

Perfect width and height to fit in


every laboratory furniture

fig. MP 135 SG

820 mm

fig. ML 135 SG

560 mm

Built-in and sub-assembly laboratory / pharmaceutical


refrigerators and deep freezers for preserving
temperature-sensitive products

Dometic Medical Systems offers six models of refrigerators and freezers that
Dometic Dometic Dometic
can be built in or under laboratory furniture. The dimensions fit perfectly for
these needs and the cooling/ freezing appliance can be practically integrated in
a space-saving way in your workplace.
safety safety
standard GREEN standard
Thanks to their advantageous dimensions and design the models BR GOLD standard Silver

110 G/GG, FR 110 G/GG, LR 110 G/GG and PR 110 G/GG are usable as
either the stand alone version or the built-in/sub-assembly version.
Models ML/MP 135 SG can optionally be equipped with side walls and cover in
order to get a stand alone type.

16 | 17
ML 135 SG MP 135 SG BR 110 G / GG

ML 135 SG MP 135 SG BR 110 G BR 110 GG


External dimensions (mm) 820(825*) x 560 x 545(585*) External dimensions (mm) 820(825*) x 560 x 545(585*) External dimensions (mm) 820 x 560 x 580
Gross volume (l) 135 Gross volume (l) 135 Gross volume (l) 106
Net volume (l) 118 Net volume (l) 118 Net volume (l) 92
Energy consumption 0.50 Energy consumption 0.70 Energy consumption 1.25 0.75
(Kwh/24h) (Kwh/24h) (Kwh/24h) (40 % less)

Noise level (dB(A)) 38 Noise level (dB(A)) 38 Noise level (dB(A)) 41


* stand-alone version * stand-alone version

FR 110 G / GG LR 110 G / GG PR 110 G / GG

FR 110 G FR 110 GG LR 110 G LR 110 GG PR 110 G PR 110 GG


External dimensions (mm) 820 x 560 x 580 External dimensions (mm) 820 x 560 x 580 External dimensions (mm) 820 x 560 x 580
Gross volume (l) 106 Gross volume (l) 106 Gross volume (l) 106
Net volume (l) 104 Net volume (l) 92 Net volume (l) 92
Energy consumption pending 4.00 Energy consumption 1.15 0.75 Energy consumption 1.25 0.75
(Kwh/24h) (Kwh/24h) (35% less) (Kwh/24h) (40% less)

Noise level (dB(A)) pending 47 Noise level (dB(A)) 41 Noise level (dB(A)) 41
LR 110 GG available as Internal II 3 G EEx nA II T6

Technology for Life


Transport Systems

Transport Systems for the safe transport of blood bags


The model range MT consists of four passive transport systems supplemented efficiently by a fast freezer for cooling
elements and six active transport boxes, working with the Peltier system or with a compressor.

Dometic transport systems are ideal for intensive use with many transport applications, even under difficult climatic
conditions.

MT models are conform with the European agreement on the international transport of hazardous goods by Road (ADR),
by Rail (RID), by sea (IMDG) and with the International agreement for air transport (ICAO-TI / IATA-DGR).

For all passive transport boxes eutectic cooling systems are available as an option (–32°C, +4°C, +22°C and +37°C).

MT 4 B MT 8 B MT 12 E MT 25 E

MT 4 B MT 8 B MT 12 E MT 25 E
Passive Passive Passive Passive
Dimensions (mm) 301 x 363 x 287 Dimensions (mm) 435 x 590 x 290 Dimensions (mm) 500 x 550 x 470 Dimensions (mm) 500 x 710 x 550
Gross volume (l) 8 Gross volume (l) 20 Gross volume (l) 24 Gross volume (l) 44
Storage capacity 4 at 450 ml each Storage capacity 8 at 450 ml each Storage capacity 15 at 450 ml each Storage capacity 26 at 450 ml each
(blood bags) 6 at 270 ml each (blood bags) 14 at 270 ml each (blood bags) 25 at 270 ml each (blood bags) 40 at 270 ml each

MT 42 P MT 100 MT 900

MT 42 P MT 100 MT 900
Active (Peltier) Active (Compressor) Active (Compressor icepack freezer)

Dimensions (mm) 500 x 840 x 550 Dimensions (mm) 1000 x 520 x 800 Dimensions (mm) 1805 x 595 x 720

Gross volume (l) 43 Gross volume (l) 90 Gross volume (l) 247

Storage capacity 30 at 450 ml each Storage capacity 48 at 450 ml each Storage capacity 179 cooling
(blood bags) (blood bags) ele­ments at 0.6
50 at 270 ml each
each
Application range –32°C to +43°C Application range –2°C to 43°C Application range 16°C to 43°C
(amb. temp.) (amb. temp.) (amb. temp.)

18 | 19
Dometic Electronic

MT 18 MT 50 MT 80 MT 110

MT 18 MT 50 MT 80 MT 110
Active (Compressor) Active (Compressor) Active (Compressor) Active (Compressor)
Dimensions (mm) 414 x 465 x 300 Dimensions (mm) 480 x 630 x 360 Dimensions (mm) 455 x 790 x 500 Dimensions (mm) 555 x 790 x 500
Gross volume (l) 18 Gross volume (l) 49 Gross volume (l) 80 Gross volume (l) 106
Storage capacity 6 at 450 ml each Storage capacity 14 at 450 ml each Storage capacity 27 at 450 ml each Storage capacity 36 at 450 ml each
(blood bags) 8 at 270 ml each (blood bags) 18 at 270 ml each (blood bags) 36 at 270 ml each (blood bags) 48 at 270 ml each
Application range +5°C to +32°C Application range +5°C to +32°C Application range +5°C to +32°C Application range +5°C to +32°C
(amb. temp.) (amb. temp.) (amb. temp.) (amb. temp.)

Dometic Electronic

The new and innovative Dometic Electronic (operation and control panel) assures thanks to its password protected
settings menu optimum protection for your stored preparations.

The menu structure of the modern and user-friendly graphic display offers a simple and intuitive utilization.

LED “Alarm„ Navigation buttons Settings menu Extra menu

 Power switch, LED “Power on„ Back button Menu button


key-operation
O = OFF / I = ON

The new Dometic Electronic also offers:

≥ A wide range of adjustment and diagnostic ≥ An optional 4...20 mA outlet to transmit
facilities as well as additional protection / temperature data of a sensor connected to
warning operations (via external alarm the electronic (see picture).
operations, histories and individual display ≥ Connection facilities for additional (optional)
signals). temperature sensors.
≥ An optional PT 100 sensor inlet to show ≥ DMN (Dometic Monitoring Network) and
the sensor’s temperature the (optional) DCU (Dometic
data on the display as well Communication Unit) allows
as forwarding and further illustration of texts on the
processing via a 4 ... 20 mA product’s display.
outlet.

Technology for Life


Dometic Software

DMN – Dometic Monitoring Network


Universal software for collection, long-term recording and visualization of
temperature data.

≥ Complete activity list (password protected).  ree of charge for all Dometic Gold & Silver ranges
≥ F
≥ Integrated event and activity history of all appliance  eal-time temperature output for third-party
≥ R
components. software
≥ Graphical visualisation of all temperature curves. Your essential advantages:
 onnection to existing or third-party appliances via
≥ C Access to the data within your entire network via
network technology (LAN, WLAN, WAN). one central database
≥ Simultaneous data monitoring and recording. Economy of time and money as regular changes
≥ Possibility for specific and individually configurable of recorder paper, ink or battery are not necessary.
alarm forwardings, e. g. via email, SMS (with optional
GSM module) or via DECT.
≥ Simple and intuitive utilization.
 ssential price advantage compared to a traditional
≥ E
circular chart recorder and its spare parts. 4

DCU – Dometic Communication Unit


Hardware module that notes all operating conditions and passes them through to
a central data base – via local network, to which devices are connected.

≥ Interface connection of Dometic appliances to an  ossibility of connection of several additional self-


≥ P
existing network. sufficient temperature sensors (up to 4 PT1000 &
≥ The DCU offers direct connection to the Ethernet, 2 PT100).
even wireless, to the serial BUS RS 485, as well as Your essential advantages:
to the central building control system (4 ... 20 miliA). 
One integrative system for collecting all
 ossibility of connection of actuators (4 ... 20 milliA out).
≥ P temperature relevant appliances and ambients.
≥ Digital IN/OUT ( customer-specific use of these 
Many different connection facilities allow flexible
connections is programmable). upgrades for individual projects.
 he integrated USB port allows stored data to be
≥ T
written to an external memory stick.
 ecording and storage of relevant data of the
≥ R
appliance. CON1: DC inlet
CON2: Electronic
≥ The DCU replaces the paper temperature recorder. CON3: -----
CON4-6: Add.
sensors
 he DCU works with all Gold electronics from
≥ T WLAN (option)

2000 on USB Remote Ethernet LAN

CON7: 4-20mA / USB


 ll data are recorded and saved in the data base of
≥ A RS 232
CON8: RS 485
the DMN and are available for analysis at any time.

DMN & DCU in combination offer a highly flexible system that is adaptable to specific customer requirements
≥ C omplete & legally safe documentation of temperature data
≥ Comprehensive applications and diagnostic possibilities

20 | 21
Blood Safety

Blood Safety
Global Safe Blood Management
Ensuring a safe and secure supply of blood and blood products, as
well as the appropriate and rational use, are important public health
responsibilities of every nation and government.

“Blood Safety” comprises different activities from collection to transfusion.

eutectic
Blood Traceability
RFID technology for a complete traceability and
identification of RBCCs

Blood Cold Chain


A selected range of products for an uninterrupted and
precisely temperature controlled blood cold chain

Technology for Life


Blood Traceability

Global Haemovigilance at a glance

The newly developed Blood Traceability system “Biolog”


with RFID chips integrated into the blood bags label RFID ( Radio Frequency Identification ) is now ready
provides a complete traceability and identification of for today‘s blood transfusion. The Dometic RFID
RBCC’s and avoids retranscription errors. It is a system “Biolog” offers you all the necessary hardware
computerised management system of the transfusion and software from donor to receiver : Physical
chain and its main advantages are: traceability, cold chain surveillance, auto­
matic stock management (FIFO), stock
≥ Perfect Cold Chain surveillance optimization, electronic cross matching
≥ Rationalised distribution of blood bags between donor and receiver, clinical data
≥ Global management of national stock registration, transfer of data between sites
≥ Guarantee against transfusion errors and elimination of human errors.

The “Dometic powered by Biolog” solution is the first global


traceability system covering all life cycles of the blood bag.

Interactions within the BIOLOG solution

22 | 23
Biolog Solution

The RFID donor card manages all donor data nation be made between the RFID label on the bag and the
wide and even across borders if wished. Once the RFID bracelet from the receiver avoiding crossmatching
donation occurrs the RFID label will allow at all time the errors.
monitoring and management of all clinical information, When a bag is delivered but not transfused a remote
transport and storage temperatures and conditions, secure and controlled reallocation can be done through
destination and receiver information. The system fully the system without physically moving the RBC bag,
assists the dispatching phase with the search for a allowing optimal use of existing stock.
specific blood bag and the elimination of human error.
True stock is constantly monitored and managed in real
time with automatic optimization of thresholds, expiry
dates and choice of products.
The RBC bag is at all time within an intelligent transport
container or intelligent blood refrigerator allowing each
bag to carry its own history from donor to receiver. Upon
arrival at the healthcare centre all data is downloaded
and transferred automatically avoiding any transcription
error. Prior to transfusion an electronic crossmatch can

Biolog Hardware

Electronic RFID tags which Dual technology printer which “Intelligent” RFID blood bank Transport container for blood
allow writing and reading of data allows both printing of the refrigerator which allows precise transportation with unique
(product code, donor identifica- secondary tag and encoding of its knowledge of date of receipt, identifier (barcode)
tion no., ABO Rh (D) grouping, electronic RFID chip. issue date, last return date status
extended phenotype, expiry of each bag, storage conditions
date, ….) (temperature, …)

Temperature sensor consisting of Barcode reader to identify labels Server located at the blood bank Workstation connected to the
a recorder and a receipt module from blood bag + transport box institution to connect all parts + blood bank refrigerator, consisting
which registers the temperatures sites within the transfusion chain of an RFID reading position and a
during transport and forwards data temperature controller
to the server.

Technology for Life


+4°C I Dometic Intelligent Blood Bank Refrigerators BR

Each blood bag is equipped with a RFID chip


that registers all relevant transfusion data.

Each drawer has RFID detectors for every


cell in order that all blood bags are indivi-
dually identified and supervised.
BR 490 G Biolog

Intelligent blood refrigerators for a consistent tracing


of blood bags

Dometic Medical Systems has adapted four of its blood refrigerators for the Biolog solution. Dometic

RFID detectors for each drawer level observe the presence or movement of the blood bags in
the different cells of the drawers.
safety
standard
GOLD

24 | 25
Dometic Intelligent Blood Bank Refrigerators BR I +4°C

BR 250 G BR 410 G

BR 250 G BR 410 G
External dimensions (mm) 1305 x 850 x 785 External dimensions (mm) 1735 x 850 x 785
Gross volume (l) 246 Gross volume (l) 408
Net volume (l) 167 Net volume (l) 319
Storage capacity 32 Storage capacity 80
(blood bags) (blood bags)

Energy consumption (Kwh/24h) 1.50 Energy consumption (Kwh/24h) 1.70


Noise level (dB(A)) 49 Noise level (dB(A)) 51

BR 490 G BR 750 G

BR 490 G BR 750 G
External dimensions (mm) 1950 x 850 x 785 External dimensions (mm) 1990 x 910 x 985
Gross volume (l) 489 Gross volume (l) 746
Net volume (l) 395 Net volume (l) 620
Storage capacity 104 Storage capacity 210
(blood bags) (blood bags)

Energy consumption (Kwh/24h) 1.90 Energy consumption (Kwh/24h) 2.00


Noise level (dB(A)) 51 Noise level (dB(A)) 51

Technology for Life


Dometic Biolog MT Range

Biolog
temperature logger
The Biolog temperature logger records the
temperature of the RBCC’s continuously
(Integrated to the MT Boxes).

The temperature logger is read before and


after transportation to have always most
actual data.

Before every transportation the battery of


the logger is automatically verified.

fig. MT 8 B

Blood boxes for a safe traceability of blood bags


during transport

Dometic Medical Systems Transport Boxes are an essential link within the Biolog solution. The temperature logger
always ensures perfect temperature-controlled conditions during transport. The quality of the transported blood
bags is not left to chance.

26 | 27
Dometic Biolog MT Range

MT 4 B MT 8 B

MT 4 B MT 8 B
Passive Passive

External dimensions (mm) 301 x 363 x 287 External dimensions (mm) 435 x 590 x 290

Gross volume (l) 8 Gross volume (l) 20

Storage capacity (blood bags) 4 at 450 ml each Storage capacity (blood bags) 8 at 450 ml each

6 at 270 ml each 14 at 270 ml each

MT 12 E MT 25 E

MT 12 E MT 25 E
Passive Passive

External dimensions (mm) 500 x 550 x 470 External dimensions (mm) 500 x 710 x 550

Gross volume (l) 24 Gross volume (l) 44

Storage capacity (blood bags) 15 at 450 ml each Storage capacity (blood bags) 26 at 450 ml each

25 at 270 ml each 40 at 270 ml each

Technology for Life


Blood Cold Chain

Periphery Transport

Blood Collection Transport of


at Peripheral Centres Unscreened Blood / Plasma
to Technical Platform

Storage Transport of Screened Blood / Plasma


at Peripheral Centres to Peripheral Centres
UF / FR / BR MT

“ Ensuring a safe, secure and ethical supply of blood and blood products and
the appropriate and rational clinical use of blood are important public health
responsibilities of every national government. A prerequisite for blood safety is
the existence of a national blood transfusion system, based on voluntary non-
remunerated donation and with every aspect governed by quality management.
Such systems should be nationally coordinated, financially sustainable and
able to respond to any newly emerging blood safety threat ”. *

Blood Cold Chain is one key component for Blood Safety and comprises
different activities involving equipment that need to offer perfect storage and
transport from the beginning (collection) to the end (transfusion). Blood is
collected at a body temperature (~ 37°C), to keep it safe and to avoid bacterial
contamination it has to be cooled and stored between +2°C and +6°C, with a
set point of +4°C (for a period of around 35 days of storage).

28 | 29
Technical Platform

Storage of Screening,
Unscreened Testing, Production
Blood Processing

BR

lls
ML

e
C

Plasma
d
e
R
Blood

BR
Plasma

FR / UF

Storage of Screened Contact Shock


Blood / Plasma Freezing Plasma
MBF

“ Plasma components must be shock frozen below units are often lost during the transport from the blood
-30°C within a short period of time and stored at bank to the hospital and inside these buildings. Too
temperatures that will adequately maintain the labile often, ordinary untested cold boxes which are unable
coagulation factors in a functional state (for a period to maintain the cold life on a long distance and period
around 24 months when stored below –25°C and are responsible for significant waste.
3 months at –18°C to –25°C)”. *
A perfect effective blood cold chain is only
We evaluate that around 7%** of the collected blood available with tested and technically proven
for transfusion needs can be wasted for different products, which respect international norms
reasons (the main one is due to missing traceability). To and follow WHO tested specifications.
decrease this percentage during the blood cold chain,
So it is with Dometic medical products.
Dometic Medical Systems has developed a range of
different products with strong safety standards. Blood
* Statement from WHO / ** Figures from WHO

Technology for Life


Biotech Systems

Biotech Systems
Secure Life Sciences solutions
Critical and highly sensitive research material in research centres places a higher demand
in the processing of these substances in terms of product and operator protection. Both of
these points have been given the highest priority during the development of the “Biotech
Systems” range.

Biological Class II Safety Cabinets


For sterile product preparations and biological
experimentation involving agents of low and
moderate risk

CO2 Incubators
For essential thermal control of preparations in research
centres, clinical biochemistry, microbiology and industry

30 | 31
Safety Cabinets

Unique airflow management for personal, product


and environmental protection

With its Biological Safety Cabinets, Dometic offers a unique airflow management system and proven containment
technology combined with user-friendly ergonomic design.

Dometic Biological Safety Cabinets are designed for sterile product preparations and biological experimentation
involving agents of low and moderate risk. When exhausted into the room, the Safety Cabinets are classified Class
II, Type A2 cabinets.

Properly vented to the outdoors through a facility exhaust system, the Safety Cabinets exceed minimum standards
for Class II, Type A2 cabinets (formerly B3).

Room Air

Contamined Air negative pressure

Contamined Air positive pressure

ULPA-Filtered Air

BSC-SG403EN BSC-SG603EN

BSC-SG403EN BSC-SG603EN
Exterior dimensions (H x W x D mm), 2030 x 1362 x 776 Exterior dimensions (H x W x D mm), 2030 x 1972 x 776
with telescopic legs with telescopic legs
Interior dimensions of usable 699 x 1168 x 511 Interior dimensions of usable 699 x 1778 x 511
workspace (H x W x D mm) workspace (H x W x D mm)
Noise level (dB(A)) 55 Noise level (dB(A)) 60

Down flow velocity (m/s) 0.25 Down flow velocity (m/s) 0.25

ULPA filter ULPA filter

Technology for Life


Incubators

CO2 Incubators for precise temperature control

Research centres, clinical biochemistry, microbiology and the industry represent the areas where thermal control
is essential. The new generation of Dometic Incubators have been designed especially for these needs. Our
incubator range is defined by two volumes: 80 and 165 litres

Important features:

≥ Forced air convection

≥ Delivered with perforated non tipping


over shelves

≥ Turbine ventilation to ensure a better


uniformity when fully loaded

≥ Dry heat sterilization cycle (140°C, 2h)

≥ High temperature
visual and acoustic alarm

≥ Overtemperature protection

BTI-80 DRS BTI-165 DRS

BTI-80 DRS BTI-165 DRS


External dimensions (mm) 760 x 533 x 506 External dimensions (mm) 915 x 625 x 635
Capacity (l) 80 Capacity (l) 163
Sterilization cycle temperature 60°C – 140°C (1°C step) Sterilization cycle temperature 60°C – 140°C (1°C step)
CO2 range 0% - 20.00% CO2 range 0% - 20.00%
CO2 sensor IR sensor CO2 sensor IR sensor
Relative humidity 95% Relative humidity 95%

32
Dometic Group is a customer-driven, world-leading provider of leisure products for the RV,
automotive, truck and marine markets. We supply the industry and aftermarket with a complete
range of air conditioners, refrigerators, awnings, cookers, sanitation systems, lighting, mobile
power equipment, comfort and safety solutions, windows, doors and other equipment that make
life more comfortable away from home.

Dometic GROUP supplies a wide range of workshop equipment for service and maintenance of
built-in air conditioners.

Dometic GROUP also provides specially designed refrigerators for hotel rooms, offices, wine
storage and transport and storage of medical products.

Our products are sold in almost 100 countries and are produced mainly in wholly-owned
production facilities around the world.

33 | 33
Technology for Life

Subject to change without prior notice. Some of the accessories shown in the pictures are optional.
Discover the world of Dometic Medical Systems

For more information:

Dometic S.àr.l
02/2012

Division Medical Systems


17, Op der Hei
L-9809 Hosingen, Luxembourg
Tel.: + 352 92 07 31-1
292.9707.28

Fax: + 352 92 07 31-300


medical.systems@dometic.lu
www.dometic.lu

www.dometic.lu

You might also like