N
Information ”
‘Issued by: FURUNO ELECTRIC CO,, LTD
‘SERVICE MANAGEMENT & COMMANDING DEPARTMENT
APPROVED BY,
WRITTEN BY,
FELCOM 11/12, IB-581
Combination of Software
Urgency: When servicing.
io. : __F05-2002-010
te: __ 2002-06
The 1B-581 must be used with Inmarsat C FELCOM 11/12 in a correct combination
of software version. If not, "Ignored: Undefined Command ID.” error message will
appear, or some functions will not work properly. The IB-581 is shipped with the
newest version. The following summarizes the combinations.
FELCOM 11
Change | Y2K compliance Improving data Capability of
tobe reporting capability, | Russian VMS
made etc. (FO5-1999-020)
CPU2 | 165-0087-104 165-008 7-105, 165-0087-106
1B-581 [165-091-016 165-0091-017
FELCOM 12 _
Change | Y2K Cire.862 Related to Related to
lobe compliance | (FQ5-1999-015)| FFA/VMS vMs
made (FQ5-2000-014) |
CPU2 _[165-0118-104" | 165-01 18-106
“| 165-0118-107
165-0118-107
*: Updating the program requires the hardware changes such as replacement of
distress button cover and key seal.
FELOCM 81
The newest program (165-0109-104) of the IB-S81 is used in combination with any
version of the FELCOM 81 software.
DP-6
Use the following combination. (Related Furuno Information: FQ5-2002-001)
Main software: 055-0187-118
Terminal software: 055-0189-121
IB-581 _|185-0116-103 | 165-0116-104 | 165-0116-105 | 165-0116-106 iS
Change | Related to dala Solving the problem | Capability of ss
tobe reporting for the built-in GPS Russian VMS
made VMS: remains in ACQ status’
if external GPS is
connected _
CPU 165-0118-108 | 165-0118-109 165 0118 114
18-581 165-0116-106 165-016-106 165-0116-106