Professional Documents
Culture Documents
Triple-Band Combiner: GSM/LTE 1800 UMTS 2100 TDD/FDD 2300 / WIFI / LTE 2600
Triple-Band Combiner: GSM/LTE 1800 UMTS 2100 TDD/FDD 2300 / WIFI / LTE 2600
Technical Data
Type No. 78211400 78211402 78211404 78211406
Single Unit Single Unit Single Unit Single Unit
78211401 78211403 78211405 78211407
Double Unit Double Unit Double Unit Double Unit
Pass band
Band 1 (GSM/LTE1800) 1710 – 1880 MHz
Band 2 (UMTS2100) 1920 – 2170 MHz
Band 3 (2300 ... LTE2600) 2300 – 2700 MHz
Insertion loss
Port 1 ↔ Port 4 < 0.3 dB (typ. 0.1 dB)
Port 2 ↔ Port 4 < 0.3 dB (typ. 0.1 dB)
Port 3 ↔ Port 4 < 0.3 dB (typ. 0.1 dB)
Isolation
Port 1 ↔ Port 2 > 50 dB (1710 – 1880 / 1920 – 2170 MHz)
Port 1 ↔ Port 3 > 50 dB (1710 – 1880 / 2300 – 2700 MHz)
Port 2 ↔ Port 3 > 50 dB (1920 – 2170 / 2300 – 2700 MHz)
Subject to alteration.
Port 1 ↔ Port 4 By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop Stop
Port 2 ↔ Port 4 By-pass (max. 2500 mA) Stop By-pass (max. 2500 mA) Stop
Port 3 ↔ Port 4 By-pass (max. 2500 mA) Stop Stop By-pass (max. 2500 mA)
Lightning protection 3 kA, 10/350 μs pulse
Mounting Wall mounting: With 4 screws (max. 8 mm diameter)
Mast mounting: With additional clamp set
Weight Single unit: 3.5 kg / Double unit: 6.9 kg
Packing size Single unit: 390 x 310 x 130 mm / Double unit: 390 x 310 x 180 mm
Dimensions (w x h x d) Single unit: 235 x 216.5 x 46.45 mm / Double unit: 235 x 216.5 x 96.95 mm
(without connectors, without mounting brackets)
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-820
Triple-Band Combiner
1710 – 1880 MHz 1920 – 2170 MHz 2300 – 2700 MHz
GSM/LTE 1800 UMTS 2100 TDD/FDD 2300 / WIFI / LTE 2600
Attenuation / dB
734360 34 – 60 mm 1710 - 1880 1920 - 2170 2300 - 2700
-10
734361 60 – 80 mm
734362 80 – 100 mm DC stop -20
-80
1680 1780 1880 1980 2080 2180 2280 2380 2480 2580 2680 2780
Frequency / MHz
-0,10
-0,20
46,45
64,45
22
-0,30
40
-0,50
96,95
114,95
50,5
-0,60
22
-0,70
40
277,5 -0,80
216,5
-0,90
-1,00
1680 1780 1880 1980 2080 2180 2280 2380 2480 2580 2680 2780
69,25
Frequency / MHz
102
235
64
35
Please Note:
95
Subject to alteration.
The mounting plates can be removed by loosening the screws to (M5 x 12) and replaced
with other means of mounting, always provided that the max. drilled depth of
98,75
As a result of more stringent legal regulations and judgements regarding product liability,
we are obliged to point out certain risks that may arise when products are used under
332 extraordinary operating conditions.
302
190 Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g.
strain caused by oscillating support structures), may result in the breakage of a mast mounted
device or even cause it to fall to the ground.
Ø8 The Triple-band Combiners are designed to operate under the environmental conditions
936.4820/a
,5
as described in ETS 300 019-1-4 class 4.1 E and have passed environmental tests as
recommended in ETS 300 019-2-4.
122
65
The installation team must be properly qualified and also be familiar with the relevant
national safety regulations.
7