Heat Transfer
1. A brick wall [ k= 0.69 W/(m.°C)] 5 cm thick is exposed to cool air at 10°C
with a heat transfer coefficient of 10 W/(m?.°C) at one of its surface,
while the other surface is kept at 70 °C. What is the temperature of the
surface that exposed to cool air?
2. Consider a furnace wall [ k= 1 W/(m.°C)] with the inside surface at
1000°C and the outside surface at 400 °C. If the heat flow through the
wall should not exceed 2000 W/m’, what is the minimum wall thickness?
3. A metal pipe with an outside diameter (OD) of 12 cmis covered with an
insulation material [ k=0.07 W/(m.°C)] of 2.5 cm thick. If the outer pipe
wall is at 100 °C and the outer surface of the insulation is at 20 °C, find
the heat loss from the pipe per meter length.
4. A metal pipe of 10 cm OD is covered with a 2 cm thick insulation [ k=0.07
W/(m.°C)]. The heat loss from the pipe is 10 W per meter of length when
the pipe surface is at 100 °C. What is the temperature of the outer
surface the insulation?