SER and TSR Starbars are described by giving the overall length, the
heating section length, and the diameter. As an example, SER 24 x 16 x
1.25 is a Spiral Starbar 24 inch long with a 16 inch hot zone and an
outside diameter of 1.25 inch. In millimeters an SER 610 x 406 x 32 is a
Spiral Starbar 610mm long with a 406mm hot zone and an outside
diameter of 32mm.
Table A
SER Starbar Dimensions
Starbar Collar Collar **Max. **Max. ***Max. *Starbar Uncut
Diameter Diameter Location Heating Overall Load Tube ID end of hot zone
Length Length OD
mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in.
13 1/2 38 1-1/2 50 2 250 10 533 21 2 1/16 5 3/16 13 1/2
16 5/8 38 1-1/2 50 2 250 10 559 22 5 3/16 8 5/16 13 1/2
19 3/4 38 1-1/2 50 2 406 16 635 25 6.5 1/4 9.5 3/8 13 1/2
22 7/8 57 2-1/4 50 2 508 20 914 36 9 3/8 12 1/2 13 1/2
25 1 57 2-1/4 50 2 508 20 914 36 11 7/16 14 9/16 13 1/2
32 1-1/4 57 2-1/4 50 2 508 20 991 39 14 9/16 17 11/16 19 3/4
35 1-3/8 57 2-1/4 76 3 610 24 1016 40 18 11/16 21 13/16 19 3/4
38 1-1/2 57 2-1/4 76 3 610 24 1016 40 21 13/16 24 15/16 19 3/4
44 1-3/4 76 3 76 3 610 24 1016 40 24 15/16 27 1-1/16 19 3/4
54 2-1/8 76 3 76 3 610 24 1219 48 30 1-3/16 33 1-5/16 25 1
70 2-3/4 95 3-3/4 100 4 1016 40 1549 61 46 1-13/16 48 1-7/8 38 1-1/2
TSR Starbar Dimensions
44 1-3/4 The TSR normally does 305 12 610 24 29 1.14 37 1.46 13 1/2
50 2 not require a collar, 305 12 635 25 32 1.25 40 1.57 13 1/2
55 2-1/8 but can be made 305 12 635 25 36 1.41 44 1.73 13 1/2
62 2-1/2 with one. 305 12 660 26 46 1.81 54 2.12 16 5/8
75 3 305 12 660 26 59 2.32 67 2.63 16 5/8
*The SER Starbar inner diameter is normally plugged at the electrical termination end (unless specified as clear ID). The TSR Starbar inner diameter is clear.
**Recommended maximum lengths = 70% of maximum lengths listed above.
***The maximum load tube diameter is based on the overall length of the SER or TSR Starbar. Due to different thermal expansion rates, ovalness and lack
of straightness of both the Starbar and load tubes, further reductions may be needed.
To compute the nominal network voltage required to The temperature of the kiln or furnace is controlled by
power a set of Starbars, a combination of the previous an off-on controller. When the Starbars are new, they
two formulas is used as follows: En = √(Wt x Rn), (En will only be powered for 20/25 or 20/30 of the time (the
= nominal network voltage, Rn = network resistance, Wt ratio of the power needed to the power available). As
= total wattage output). the Starbars increase in resistance, they will be on for a
greater percentage of the time. When they have
increased in resistance to a point at which they supply
30,000 watts, they will be on 100% of the time. A SCR
(silicon controlled rectifier) or thyrister can also be used.
Table C
SER Recommended Minimum
Refractory Hole Diameter
Starbar Recommended
Diameter Minimum Refractory
Hole Diameter
MM Inch MM Inch
13 1/2 16 5/8
16 5/8 19 3/4
19 3/4 23 7/8
22 7/8 27 1-1/16 RECOMMENDED SER STARBAR SPACING
25 1 30 1-3/16
32 1-1/4 39 1-1/2 X = 2 x Starbar diameter is the minimum,
35 1-3/8 42 1-5/8 1.5 x Starbar diameter is the absolute minimum
38 1-1/2 42 1-11/16 and requires a reduced Starbar surface watt
44 1-3/4 49 1-15/16 loading
54 2-1/8 60 2-3/8
70 2-3/4 77 3-1/32 Z = S ÷ 1.41 minimum for stationary loads
Recommended Minimum
Z = S ÷ 1.73 minimum for moving loads
Refractory Hole Diameter for TSR
Cold End S = 2 x Starbar diameters minimum
44 1-3/4 49 1-15/16
50 2 55 2-1/4 X - distance from the centerline of Starbar to any
55 2-1/8 61 2-11/16 reflecting surface, such as a refractory wall or
62 2-1/2 69 2-3/4 product
75 3 84 3-5/16
Z - distance from the centerline of the Starbar to a
moving or stationary load
Starbars should not be placed closer than two Starbar S - distance from centerline of the Starbar to the
diameters to each other or one and one half Starbar centerline of an adjacent Starbar
diameter to a wall or other reflecting body. If the Starbar
is not able to dissipate heat energy equally in all
directions, it may overheat and possibly fail.
AVAILABILITY
Starbars can be shipped from stock, or
two to three weeks after receipt of an
order.
CUSTOM CONFIGURATIONS
The ID of the SER cold end is normally plugged.
Alternatively, the SER is available with a clear ID
which allows it to be used as a tube heater. The
SER should be used as a tube heater rather than
the TSR whenever possible because the wall is
thicker making it stronger. The TSR should be
used only when the SER ID is not large enough.
Figure 4