Model NC1991 Series

Commercial Water Heater


Specification Sheet
Job Name _______________________________________________________________________
Location ________________________________________________________________________
Architect/Engineer _______________________________________________________________
Wholesaler ______________________________________________________________________
Contractor ______________________________________________________________________
Model No. _______________________________________________________________________
Gas Type ________________________________________________________________________
No. of Units _____________________ Total BTU/hr Input _________________________________
Flow Rate (GPH) ___________________________________________________________________
Notes

- gas consumption ranges from 16,000 BTUh to


199,900 BTUh

- ANSI Z21.10.3/CSA 4.3 certified design that can


be wall-mounted indoors with a -DVC model or installed outdoors
with an -OD model

- manufactured with commercial grade copper,


25% thicker piping than standard models

- available in Outdoor (-OD) or Concentric Direct Vent


(-DVC) model that requires 5/3 in. Noritz concentric stainless steel pipe

- units can be linked together by using


either the optional 2-unit Quick Connect (#QC-2) or multi-unit
System Controller (#SC-301-6M-EXT) for up to 6 units DVC Model OD Model

- BTU input can range from 16,000 to 1.2 million BTUh


for a 6-unit Multi-System
NC1991 - _____
- 84% efficient for use with natural gas or propane OD (Outdoor Vent)
DVC (Concentric Direct Vent)
- includes remote thermostat that can precisely
adjust the output temperature from 100°F to 185°F with the capability
to display temperatures in both °C and °F Isolation Valves (#IK-WV-200-1)
Pipe Cover
- Flame Sensor, Overheat Prevention Device, Lightning
Protection Device, Freeze Protection for OD Model (#PC-2S-GRY)

Quick Connect Cord (#QC-2)

& 6-Unit System Controller (#SC-301-6M-EXT)

- CSA, UPC, NSF, Low NOx Approved by SCAQMD [<14ng/J or 20ppm]


This product complies with California AB 1953 Low Lead Law and section 1417(d)
of the Safe Drinking Water Act
LOW-LEAD

CERTIFIED
R

NORITZ AMERICA CORPORATION


11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com
Dimensions
13.8" (350mm) (VIEW FROM TOP)
13.1" (334mm) 9.5" (241mm)
1.6" (41mm)

9.9" (252mm) 2.4" (61mm) 2.4" (60mm)


1.4" (36mm)
9.4" (240mm)

3.4" (88mm)
0.4" (10mm) 0.4" (10mm)

3.1" (79mm)
7.2" (184mm)
6.4" (163mm)

4.9" (125mm)
7.8" (199mm)
1.1" (28mm) FLUE COLLAR

13.8"
13.1" FLUE COLLAR
5.0"
3.1"
22.3" (567mm)

23.6" (600mm)

1.7" (42mm)
AIR INLET HOT WATER OUTLET (3/4") COLD WATER INLET (3/4”)
WIRING THROUGHWAY GAS INLET (3/4")
5.7" (146mm) WIRING THROUGHWAY
10.3" (262mm) (AC120V)

AIR INLET
DVC Model
AIR INLET
9.5" (241mm)
2.4" (60mm)
1.4" (36mm)
0.4" (10mm) DVC Model
SIDE VIEW FRONT VIEW

6.7" (171mm)
6.1" (155mm)
5.3" (134mm)
2.0" (50mm)

3.8" (97mm)
WIRING THROUGHWAY
WIRING THROUGHWAY (AC120V)
0.4" - 1.8" 11.0"
HEIGHT OF EACH FITTING
4.8" WATER DRAIN VALVE FROM BOTTOM OF CASE
1.1" (WATER FILTER) GAS INLET NC1991 Series HOT WATER OUTLET (3/4") COLD WATER INLET (3/4")
HOT WATER OUTLET 1.8" (45mm) WIRING THROUGHWAY GAS INLET (3/4")
COLD WATER INLET 5.7" (146mm) WIRING THROUGHWAY
HOT WATER OUTLET COLD WATER INLET 2.2" (55mm) (AC120V)
10.3" (262mm)
BOTTOM VIEW GAS INLET 2.2" (56mm)
WATER DRAIN VALVE OD Model
DVC Model

Flow Rates
Temperature
Rise (°F) 30 40 45 50 60 70 80 90 100 110 120 130 140
Flow Rate
(GPM) 9.8 8.4 7.5 6.7 5.6 4.8 4.2 3.7 3.4 3.1 2.8 2.6 2.4

Pressure Loss
30

Set temperature: 120°F or less 60


25 (Storage Tank Setting w/ System
Controller: 160°F or less)
50
Pressure Loss (psi)

20 Set temperature: 125°F or higher


(Storage Tank Setting w/ System
40
Ft of Head

Controller: 170~180°F)
15
30

10
20

5 10

0 0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0
Flow Rate (gpm)

Specifications
Model Name NC1991-OD NC1991-DVC
Weight 54 (pounds) 58 (pounds)
Operating Pressure 15 - 150 psi
Gas Supply Pressure NG: 4.0” - 10.5” LP: 8.0” - 14.0”
Water Holding Capacity 0.2 Gallon (1.0 L) 0.2 Gallon (1.0 L)
Water Inlet 3/4"
Connection
Hot Water Outlet 3/4"
Sizes
Gas Inlet 3/4"
Supply 120VAC (60Hz), less than 4 amperes
Power
Consumption NG: 65W LP: 67W Freeze Prevention 161W NG: 80W LP: 83W Freeze Prevention 193W
Freeze Protection Outdoor: -4°F Indoor: -30°F
°F Mode 100-150°F (In 5°F intervals), 160, 170, 185°F (14 Options)
Temperature Settings
°C Mode 37-48°C (In 1°C intervals), 50-85°C (In 5°C intervals) (20 Options)
°F Mode 120, 135, 140, 185°F (Default is 120°F)
Default Temperature Options
°C Mode 50, 57, 60, 85°C (Default is 50°C)

ut notice.

Rev. 06/16