Terms in this set (641)
Sewage Ejector
‘Type of pump that discharges waste in the sump pit and transfers the
waste to the house drain, (Max Fajardo)
503 mm
Minimum dimension of a septic tank manhole.
Industrial drain
drain that discharges objectionable waste such as acids and other
chemicals from industrial equipment
75mm
Minimum diameter of pipe of any water closet,
Maximum number of water closets able to discharge into a shared
75mm diameter horizontal soil branch
Combination Sewer
‘Type of sewer that discharges both storm water and sewage from
households, rendered obsolete due to the health hazards it poses
Master Plumber ExamSeptic Tank
Airtight receptacle used to expedite the decomposition of elements
contained in raw sewage, usually located 115 meters from the property
UUne and 15.2 meters from the water main or any potable water source. It
's comprised of two chambers that contain anaerobic bacteria that
break down wastes.
Sedimentation
‘Term defined as the settling down or separation of solid matter
suspended in a liquid,
% Minimum slope or grade (in 6) permitted with 100mm (4) pipes.
se Lighter organic solid particles found in sewage, cesspools and septic
tanks, found floating on the liqui.
swe Term defined as the organic particles that have settled down in septic
* tanks, cesspools or sewage.
900 mm Minimum WIDTH of a septic tank for residential dwellings. (rm)
1500 mm Minimum LENGTH of a septic tank for residential dwellings. (mm)
1200 mm Minimum DEPTH of a septic tank for residential dwellings. (mm)
Master Plumber ExamDrainage, Waste and Vent
Definition of DWV
Acrylonitrile butadiene styrene
Definition of ABS
Oval
Cross sectional shape of the interior of Polybutene pipes (P8).
38mm
Minimum size of cleanouts. (mm)
Corporation Stop
‘Type of valve found in the service main, used as a control of the water
service and shut off valve when service Is disconnected.
‘Check Valve
Type of valve used to prevent backflow or reversal of flow of water,
usually found after the water meter.
Union Patente
Fitting used to describe the connection of the service pipe and water
meter. Usually used as the demarcation between the property of the
water service and water supply pipe system residential dwelling or
building
Booster Pump / Pneumatic Pump
Type of pump used to distribute water within a building or residence,
when an upfeed system cannot provide adequate pressure to supply
fixtures with potable water.
Master Plumber ExamDurham system
Type of piping system that is characterized by threading and
‘connecting cast iron pipes in the building
Teflon Tape. Material used to fuse joints or connections of Gi pipes.
Caulking Process of joining the joints and connections of cast iron pipes.
Mator Oil Type of cil used when threading Gl pipes.
Centrifugal Pump
Type of pump used for high-rise or mid-rise ulidings, when booster or
piston pumps are unavailable or inadequate.
Piston Pump.
Type of pump used for residential or low-rise buildings, and comes in
single action, double action or twin.
Drum Trap
Type of trap that is installed onty in bathtubs.
Flushometer Valve
Type of flushing valve used in commercial water closets, usually
Installed with a pressure tank that expels ar pressure and a set amount
lof water when flushing
Number of teeth per inch in a hacksaw blade used to cut GI pipes,
Master Plumber ExamTrap Seat Maximum vertical depth of liquid that a trap can contain,
‘Type of detention pit usually found in basements, used to gather and
‘Sump Pit ve ae 8
discharge waste water, sometimes withthe help of @ pump.
Vertical pipe that is used for the storage of water, usvally contains
Standpipe
pressure and is used for fire suppression,
Return Bend ‘Type of pipe with @180 degree bend.
2 Water Supply Fixture unit of a bath tub
2 Water Supply Fixture unit of a shower
Diameter of pipe used for bath tub drum traps. (Wax Fajardo, p.172)
38mm
(mm)
8 Diameter of pipe used for wash basins / lavatories. (ax Fajardo, p.172)
(mm)
75 mmm Diameter of pipe used for water closets. (Max Fajardo, p.172) (mm)
Master Plumber ExamType of connection found in a looped vent, connecting the looped vent
Bleeder
pipe to the waste pipe
sox Percentage required of liquid flow for a waste or soil pipe to have
adequate drainage or discharge
Circuit Vent ‘Type of vent that connects a battery of fixtures to a stack vent,
. A concrete sealed vault with a wooden shelter constructed for the
” collection of raw sewage
cesspool Hole in the ground curbed with stones, bricks, CHB or other materials
spe to allow raw contaminated sewage to leach into the ground.
Trap Seal Loss ‘Acommon problem in traps due to inadequate ventilation.
Unit Vent ‘Type of vent that is shared by two fixtures of the same type.
‘Type of system used in plumbing that eliminates the vent stack, relying
‘of downward pressure and suetion
Solvent System
Master Plumber Exam
‘The waste and sewage discharges form slug-lke (bullet) pressings or
pressure.volume/tiow rate
Formula for detention time of a tank
national master plumbers association of the
philippines.
NAMPAP
shut off valve
agate valve normally used to shut off flow of water from supply pipe
key cock a faucet normally turned 90 degrees to open or close
Indirect system ‘overhead tank water distribution system is a__ system
pump normally used for farm purposes
Jack pump
centrifugal rotary
pumps with turbines
building design
‘occupants
heating capacity
things to consider when sizing the hot water tank
Master Plumber Exam5 pipe sleeves must be __xthe size of & pipe they protect,
lead cleanout plugs must be made of
2 ‘minimum * for underground drainage pipe
190 temperature needed to be considered hot water_C
bedpan washer
aka clinical sink
minimum water service connections for hospital
backflow prevention device
silleocks require a__
private water source
well is considered mostly as a__
6 maximum distance in ft a2 in trap from its vent
02 maximum allowable % for soldered connections with lead pipe joints
8 maximum allowable % for soldered connections with lead
Master Plumber Examminimum clearance from a terminal and a window opening in a bullding
6 ‘maximum pipe side diameter not needing an effing manhole
r recommended size of MWSS for service pipe in 2 storey residential
3h ‘minimum water supply size for flush valve urinal
, ‘minimum water supply pipe dameter size * for fushometer valve water
closet
2 minimum water supply pipe dlameter size * for water closet without
flushometer valve
potabilty fist steps in selecting water source
residence class type occupancy water supply
restricted use
class 2 type occupancy water supply
unrestricted use
class 3 type occupancy water supply
Master Plumber Exam‘greensand filtraiton
treatment of wells for aciaity
marblestone filtration
treatment for waste water
whitesand filtration
treatment for swimming pool treatment
algae cause of objectionable tastes and odor of water
service pipe pipe from the street water main to the building served
Gvwmcv order of valves for water connection
building supply pipe:
pipe carrying potable water from the water meter to a bullding or other
point of use or distribution
fixture supply water supply pipe connecting the fixture with the fixture branch
unit vent vent installed so that one vent pipe serves two traps
‘a.group vent which starts infront ofthe extreme fixture connection on a
circuit vent
horizontal branch and connects to the vent stack
Master Plumber Exampump circu system
system used to produce a more efficient circulation of hot water to the
upper floor levels of a multi storey building
circulation of hot water by means of mechanical device
zdownfeed & gravity return system
system of where het water rises on the the highest point of the
plumbing system and travels to the fixture via gravity
Avent to relieve the pressure ahead of moving effivent in a horizontal
rellefvent fixture branch.
‘Apipe CONNECTING UPWARD from a soil or waste stack to a vent
yowe vent stack for the purpose of preventing pressure changes in the stack
5 yoke vent is required for every _ floors
6 house sewer is part ofthe plumbing system which extends __m from
the foundation of the wall of the building